HomeMy WebLinkAboutCity Council-Agenda Packets-5/6/2003
City of
Texas
AGENDA
CITY COUNCIL MEETING
5400 BRANSFORD ROAD
MAY 6, 2003
5:15 P.M. - PRE-COUNCIL AGENDA
PC- 1. Discussion of May 6, 2003 City Council regular agenda items
REGULAR AGENDA
6:45 P.M. - CALL TO ORDER
ROLL CALL
1. EXECUTIVE SESSION - In accordance with Texas Government Code Chapter
551 , Subchapter D
Sec. 551.071 -
Consultation with Attorney on Legal Issues Raised by Public
Hearing or Action Items on the Agenda
Legal - Potential Litigation - Explorer Pipeline
Sec. 551.071 -
7:30 P.M. - RESUME REGULAR MEETING
INVOCATION: Pastor Timothy Perkins, Crown of Life Lutheran Church
PLEDGE OF ALLEGIANCE: Ross Foster, City Attorney
P.O. BOX 185 COLLEYVILLE, TEXAS 76034 (817) 577-7575
2. READING AND PUBLIC HEARING - Resolution R-03-2141 - Canvassing the
General City Council Election for Mayor and Places 1 and 2 and Special Election
To Fill An Unexpired Term, Council member, Place 4, held May 3, 2003
3. OATHS OF OFFICE - MAYOR AND COUNCILMEMBERS, PLACES 1, 2 and 4
4. RECEPTION FOR MAYOR AND COUNCILMEMBERS
5. ELECTION OF MAYOR PRO TEM
6. CORRESPONDENCE, MISCELLANEOUS REPORTS OF MEETINGS
ATTENDED BY THE COUNCIL AND CITY OFFICIALS, AND
ANNOUNCEMENTS, PROCLAMATIONS, OR PRESENTATIONS
PROCLAMATION -
In recognition of National Police Week, May 10 -18, 2003 -
Police Chief John Young and Officer Bill Hudgins
PRESENTATION -
Plaques will be presented to Mayor Donna Arp and
Councilmembers Joe Hocutt and Jim Moore
CONSENT:
7. READING AND PUBLIC HEARING - Resolution R-03-2142 - Consent Items:
a. Approval of minutes of the regular City Council meeting of April 15, 2003
b. Approval of minutes of the City Council Worksession of March 26, 2003
c. Approval of the recommendation of the Sign Board of Appeals for a
variance to allow a 6' tall by 11' wide by 22" deep sign at the entrance of
Good Shepherd Catholic Community on Tinker Road with the requirement
that the light be turned off at 10:00 p.m. and allow the existing signs to
remain, Case G-03-007
d. Approval of the recommendation of the Sign Board of Appeals for a
variance to allow a 5' by 10' changeable letter marquee wall mounted sign
above the steps on the eastern side of the Sunbelt Gymnastics building
located at 4701 Bransford Road, Case G-03-008
PUBLIC HEARINGS:
8. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1403 -
Approval of Amendments to Chapter 14 of the Land Development Code
regarding drainage, fire lane, construction plans and other engineering
requirements, Case G-03-006
9. FIRST READING AND PUBLIC HEARING - Ordinance 0-03-1404 - Approval
to amend Ordinance 092-880 establishing the fee structure for the circulation of
materials and replacement and processing fees for materials for the Colleyville
Public Library
10. READING AND PUBLIC HEARING - Resolution R-03-2143 - Approval to
amend Resolution R-02-1925 Authorizing the Approval of the 2001 Drainage
Bond Project List
11. READING AND PUBLIC HEARING - Resolution R-03-2144 - Approval of a
Construction Contract for Welsh Circle Paving Improvements Project with J.L.
Bertram Construction and Engineering, Inc., in the amount of $102,763
12. READING AND PUBLIC HEARING - Resolution R-03-2145 - Approval of an
Interlocal Agreement with Tarrant County for Glade Road, Rose Street, Cherry
Avenue, Lowrie Road and Reagan Road improvements, in amount not to exceed
$65,000
TABLED ITEMS:
13. READING AND PUBLIC HEARING - Resolution R-03-2124 - Approval of a
waiver of perimeter street improvement requirements on Lot 3R, Block 2,
Thompson Terrace, located at 5009 Thompson Terrace, Case P-02-045
REPORTS:
14. PLANNING AND ZONING COMMISSION MINUTES - March 24, 2003
PLANNING AND ZONING COMMISSION MINUTES - April 14, 2003
COLLEYVILLE LIBRARY BOARD MINUTES - March 10, 2003
HISTORICAL PRESERVATION COMMITTEE MINUTES - March 11,2003
ZONING BOARD OF ADJUSTMENT MINUTES - March 25, 2003
CITIZEN COMMENTS:
15. CITIZEN COMMENTS/PRESENTATIONS REGARDING ITEMS NOT ON THE
AGENDA
ACTION/RESOLUTION:
16. DISCUSSION AND CONSIDERATION OF A RESOLUTION RATIFYING
COUNCIL AGENDA ACTION FOR THE MEETING OF MAY 6, 2003 - Reading
and Public Hearing - Resolution R-03-2146
ADJOURNMENT:
17. ADJOURNMENT
I hereby certify the above agenda was posted on the bulletin board at City Hall on Friday, May 25, 2003,
at 5:00 p.m. . ~
~ Singleton, TR
City Secretary
If you plan to attend this public meeting and have a disability that requires special
accommodations, please advise the City Secretary at least 48 hours in advance at
817.577.7575, and reasonable accommodations will be made to assist you.
PRE-COUNCIL
CllY 1)(
CG~n1l AGENDA BRIEFING
11..~-"iI$
MEETING DATE: ! 05/06/03 CITY MANAGER ! ~
ITEM#: ' PC-1 DEPARTMENT HEAD f' J~
: FINANCE REVIEW ~ N/A
Previous Action: None
DEPARTMENT: CITY COUNCIL
SUBJECT: Discussion of the May 6, 2003, City Council regular
agenda items
This item provides the opportunity for the City Council to discuss the May 6, 2003, City Council
regular agenda items.
CITY COUNCIL
Ciryor
(Q~n1l AGENDA BRIEFING
1l':\iI$
MEETING DATE:
ITEM #:
RESOLUTION #:
05/06/03
1
N/A
CITY MANAGER
DEPARTMENT HEAD
FINANCE REVIEW
N/A
Previous Action: None
DEPARTMENT: CITY COUNCIL
SUBJECT: Executive Session - In accordance with Texas
Government Code Chapter 551, Subchapter D
EXECUTIVE SESSION - In accordance with Texas Government Code Chapter 551,
Subchapter D
Sec. 551 .071 -
Consultation with Attorney on Legal Issues Raised by Public
Hearing or Action Items on the Agenda
Legal - Potential Litigation - Explorer Pipeline
Sec. 551.071 -
CITY COUNCIL
(:,1 Y Of
CG~~JTI.1) AGENDA BRIEFING
Il,,,,;:\$
MEETING DATE: 05/06/03 CITY MANAGER
ITEM#: 2 DEPARTMENT HEAD!
RESOLUTION #: R-03-2141 FINANCE REVIEW ! N/A
Previous Action: None
DEPARTMENT: CITY COUNCIL
SUBJECT: Canvassing the General City Council Election for
Mayor and Places 1 and 2 and Special Election To
Filii An Unexpired Term, Councilmember, Place 4,
held May 3, 2003
READING AND PUBLIC HEARING
This Resolution provides for the City Council to canvass the results of the May 3, 2003,
General City Council Election for Mayor and Places 1 and 2 and Special Election To Fill An
Unexpired Term, Councilmember, Place 4, in accordance with Texas Election Code Section
67.004.
RESOLUTION R-03-2141
A RESOLUTION CANVASSING THE MAY 3,2003, GENERAL ELECTION FOR
MAYOR AND PLACES 1 AND 2 AND SPECIAL ELECTION TO FILL AN
UNEXPIRED TERM, PLACE 4
WHEREAS, a General Election was duly held in the City of Colleyville, Texas, on the 3rd
day of May 2003, for the purpose of electing a Mayor and Councilmembers
1 and 2; and
WHEREAS, a Special Election was duly held in the City of Colleyville, Texas, on the 3rd
day of May 2003, for the purpose To Fill An Unexpired Term of
Councilmember, Place 4; and
WHEREAS, the City Council has met and canvassed the votes cast in such election in
accordance with the Texas Election Code, Section 67.004; and,
WHEREAS, such canvass showed the following results:
MAYOR
Mike Taylor
Joe Hocutt
Richard Newton
PLACE 1
Dave Dudziak
Mark Skinner
PLACE 2
Elaine H. Dolan
Brad Rice
Resolution R-G3-2141
Page2of2
PLACE 4
Jon Ayers
Jerome Davis
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
THAT the canvass is hereby approved.
AND IT IS SO RESOLVED.
APPROVED THIS DAY OF
_ AYES, NAYS AND ABSTENTIONS.
2003, BY A VOTE OF
ATTEST:
CITY OF COLLEYVILLE:
Cynthia Singleton, TRMC
City Secretary
Donna Arp
Mayor
CITY COUNCIL
ell Y Of
((\J~n,?" AGENDA BRIEFING
~~t ;'"Cd
Il';>;;:-l$
MEETING DATE:
ITEM#:
RESOLUTION #:
05/06/03
3
N/A
CITY MANAGER
DEPARTMENT HEAD
FINANCE REVIEW
N/A
Previous Action: None
DEPARTMENT: CITY COUNCIL
SUBJECT: Administration of the Oath of Office to the Mayor
and Councilmembers, Places 1 , 2 and 4
City Secretary Cynthia Singleton will administer the Oath of Office to the Mayor and
Councilmembers, Places 1, 2 and 4.
In the name and by the authority of
The State of Texas
OATH OF OFFICE
I, , do solemnly
swear (or affirm), that I will faithfully execute the duties of the office of
of the
State of Texas, and will to the best of my ability preserve, protect, and defend the
Constitution and laws ofthe United States and ofthis State, so help me God.
Affiant
SWORN TO and subscribed before me by affiant on this
day of
Signature of Person Administering Oath
(Seal)
Printed Name
Title
Form #2204
CITY COUNCIL
city Of
CG'ii~,n", AGENDA BRIEFING
Tl'X,,$
MEETING DATE:
ITEM#: !
RESOLUTION #: !
05/06/03
4
N/A
CITY MANAGER j
DEPARTMENT HEAD !
FINANCE REVIEW
Previous Action: None
DEPARTMENT: CITY COUNCIL
SUBJECT: Reception for Mayor and Council members
Immediately following the Oath of Office, there will be a reception in the Council Chambers
honoring the Mayor and Councilmembers.
CITY COUNCIL
Cily r)(
((\!c5ii~~jm1J AGENDA BRIEFING
~\CI
i~':-;0~
MEETING DATE: i
ITEM#: !
RESOLUTION #:
05/06/03
5
N/A
CITY MANAGER i
DEPARTMENT HEAD i
FINANCE REVIEW
N/A
Previous Action: None
DEPARTMENT: CITY COUNCIL
SUBJECT: Election of Mayor Pro Tem
This item is provided in accordance with the City of Colleyville Charter, Section 3.06(B), for the
purpose of electing from among the Council, a Mayor Pro Tem who shall serve for the term of
one (1) year.
l 1 -------
_.~-
. ..... C~ARTER
ot
city Of
TexaS
DATED: 11/7/95
l_J
ilce
~
members to raise the membership to lour (4). These appointees shall serve until the
positions can be Iilled at the next regular or special City election.
Section 3.06
Mayor and Mayor Pro Tem:
A. The Mayor shall preside at all meetings 01 the Council, shall vote only in
case 01 a tie vote 01 the Council, and shall have veto power. The Mayor shall sign all
contracts and conveyances made or entered into by the City, and all bonds issued
under the provision 01 this Charter, and shall be the o"icial representative of the City.
The Mayor shall be recognized as the o"icial of the City by the Court for the purpose
01 serving civil process. (Amended April 7, 1984)
B. Election of Mayor Pro Tem: Immediately following the final swearing in of all
members elected in accordance with Section 4.02 of this Charter, the new Council
shall in its first regular meeting, elect from among its members a Mayor Pro Tem who
shall serve for the term of one (1) year. (Amended April 7.1984)
C. The Mayor Pro Tem shall, in the absence 01 the Mayor, preside at all
meetings 01 the Council and shall vote on all issues belore the Council. The Mayor
Pro Tem shall have no veto p'ower. but shall per10rm all other duties of the Mayor
during the absence or disability 01 the Mayor. (Amended April 7, 1984)
D. Emergency Powers of the Mayor: In time of danger or emergency, the
Mayor may take command of the Police and govern the City by proclamation and
maintain order and enlorce all laws.
Section 3.07
Powers 01 the Council:
All powers and authority granted to the City by the Conslilution of the State of Texas
shall be vested in the Council, except as otherwise provided by law or this Charter.
The Council shall provide for the exercise thereof and lor the per10rmance of all duties
and obligations imposed upon the City by law and this Charter.
Section 3.08
Prohibitions:
A. Holding other office: Except where authorized by law, no Mayor or Council
Person shall hold any other City o"ice or employment by the City during the term lor
which he was elected to the Council, and no former Mayor or Council Person shall
hold any compensated appointive City Office or employment until one (1) year alter
the expiration 01 the term lor which he was elected. .
B. Appointments and/or removals: The members 01 the Council shall in no way
dictate the appointment or removal 01 any City administrative ollicer or employee
whom the City Manager or any 01 his subordinates are empowered to appoint, unless
otherwise provided in this Charter. The Council, by at least lour (4) allirmalive votes,
in public session, may require the City Manager to remove any employee for cause.
C. Inter1erence with Administration: Except lor the purpose 01 inquiries and
investigations by the direction 01 the Council, unless provided otherwise in this
Charter, the Council or its members shall deal with City ollicers and employees who
are subject to the direction and supervision 01 the City Manager solely through the
City Manager, and neither the Council nor its members shall give orders to any such
officer or employee, either publicly or privately, except in a state 01 declared
emergency.
5
CITY COUNCIL
cltr O(
caeCll AGENDA BRIEFING
it.~;>.:,,::>
MEETING DATE: 05/06/03 CITY MANAGER ! ,
ITEM#: 6 DEPARTMENT HEAD I aP
RESOLUTION #: N/A FINANCE REVIEW i N/A
Previous Action: None
DEPARTMENT: CITY COUNCIL
SUBJECT: CORRESPONDENCE, MISCELLANEOUS
REPORTS OF MEETINGS ATTENDED BY THE
COUNCIL AND CITY OFFICIALS AND
ANNOUNCEMENTS, PROCLAMATIONS OR
PRESENT A TIONS
PROCLAMATION -
In recognition of National Police Week, May 10 - 18, 2003 - Police
Chief John Young and Officer Bill Hudgins
PRESENTATION -
Plaques will be presented to Mayor Donna Arp and
Councilmembers Joe Hocutt and Jim Moore
,
~
1
.
';g-
~
.
~
j
i
RESOLUTION R-03-2142
A RESOLUTION APPROVING COUNCIL ACTION
UNDER CONSENT ITEMS AT THE REGULAR
COUNCIL MEETING OF MAY 6, 2003
WHEREAS, Council has taken action on certain items on the agenda under Consent
Items.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
a.
THAT the agenda decisions approved by Council action under Consent
Items as follows are hereby adopted:
THAT the minutes of the regular City Council meeting of April 15, 2003,
are hereby approved.
b.
THAT the minutes of the City Council Worksession of March 26, 2003, are
hereby approved.
c.
THAT the recommendation of the Sign Board of Appeals for a variance to
allow a 6' tall by 11' wide by 22' deep sign at the entrance of Good
Shepherd Catholic Community on Tinker Road with the requirement that
the light be turned off at 10:00 p.m. and allow the existing signs to remain,
is hereby approved.
d.
THAT the recommendation of the Sign Board of Appeals for a variance to
allow a 5' by 10' changeable letter marquee wall mounted sign above the
steps on the eastern side of the Sunbelt Gymnastics building located at
4701 Bransford Road, is hereby approved.
AND IT IS SO RESOLVED.
APPROVED THIS
AYES,
DAY OF
NAYS AND
2003, BY A VOTE OF
ABSTENTIONS.
ATTEST:
CITY OF COLLEYVILLE:
Cynthia Singleton, TRMC
City Secretary
Mayor
MINUTES OF THE
COLLEYVILLE CITY COUNCIL
APRIL 15, 2003
The Pre-Council meeting of the Colleyville City Council was called to order by Mayor
Arp on April 15, 2003, at 5:15 p.m.
ROLL CALL:
Councilpersons Joe Hocutt, Brad Rice and Jim Moore were
present. Mayor Donna Arp, City Manager Bill Lindley, Deputy City
Manager Dianne McWethy, Finance Director Terry Leake, Director
of Public Works Keith Fisher, Planner Tom Niederauer, Community
Development Director Barry LeBaron, Community Development
Manager Clayton Husband, Parks and Recreation Manager Monica
Walsh, Financial Analyst Collin Boothe, Records Manager Matt
Denton, Administrative Assistant Cindy Martin, and City Secretary
Cynthia Singleton were also present.
Mayor Pro Tem Ginny Tigue arrived at 5:18 p.m.
Councilman Rich Hendler arrived at 5:20 p.m.
PC-1. Discussion of proposed amendments to sign regulations
Community Development Director Barry LeBaron provided an overview of the Proposed
amendments to sign regulations and composition and structure of the Sign Board of
Appeals.
PC- 2. Discussion of April 15, 2003 City Council regular agenda items
There was general discussion regarding the regular agenda items.
Mayor Arp declared the meeting adjourned at 6:08 p.m.
The regular meeting of the Colleyville City Council was called to order by Mayor Arp on
April 15, 2003, at 6:45 p.m.
CITY COUNCIL MINUTES
APRIL 15, 2003
1. EXECUTIVE SESSION - In accordance with Texas Government Code Chapter
551 , Subchapter 0
Sec. 551.071 -
Consultation with Attorney on Legal Issues Raised by Public
Hearing or Action Items on the Agenda
Legal - Potential Litigation - Explorer Pipeline
Sec. 551.071 -
Mayor Arp explained that the Executive Session had been called in accordance with the
Texas Government Code Chapter 551, Subchapter D, Section 551.071 - Legal, Section
551.072 - Property Acquisition, and Section 551.074 - Personnel. She further
explained that there would be no decisions made or action taken during this time. The
meeting was recessed at 6:47p.m. and reconvened at 7:50 p.m.
The invocation was given by Pastor Royal Farris of Life Connection Church, after which
Ross Foster led the Pledge of Allegiance.
2. CORRESPONDENCE, MISCELLANEOUS REPORTS OF MEETINGS
ATTENDED BY THE COUNCIL AND CITY OFFICIALS, AND
ANNOUNCEMENTS, PROCLAMATIONS, OR PRESENTATIONS
Mr. Joe Tigue expressed gratitude to Mayor Arp for serving as Mayor and presented her
with a bouquet of roses.
Councilman Rice expressed appreciation to the citizens for participating in the Arbor
Day and Colleyville Trash Off event.
Councilman Rice expressed gratitude to Mayor Arp for serving as Mayor and
encouraged citizens to vote in the General and Special Election.
Mayor Arp presented a Proclamation to Chamber President Ret Stansberger in
recognition of Texas Families for Freedom, a military support group, which provides
donations to overseas military personnel and recognized Lee Ann Osterman, who
established the organization.
Mayor Arp presented a Proclamation in recognition of Child Abuse Prevention Month to
Dorotha Tilley, Center Coordinator for Alliance for Children.
Mayor Arp presented a Proclamation to Eagle Scout Christopher Daniel McNosky and
introduced Scoutmaster Bruce Ferrell.
Mayor Arp presented a Proclamation to Betty Jean Willbanks, Metropolitan United Way
City of Colleyville Volunteer of the Year.
2
CITY COUNCIL MINUTES
APRIL 15, 2003
CONSENT:
3. READING AND PUBLIC HEARING - Resolution R-03-2129- Consent Items:
a. Approval of minutes of the regular City Council meeting of April 1 , 2003
b. Approval of minutes of the City Council Worksession of March 22, 2003
c. Approval of minutes of the City Council and SH26 Advisory Committee
Worksession of March 26, 2003
d. Approval to amend the contract with Leach & Ames, Attorneys at Law,
P.C. for Municipal Judge services
e. Approval of an Interlocal Agreement with the State of Texas for
participation in Failure to Appear Program
Mayor Arp opened the public hearing and read Resolution R-03-2129 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Mayor Pro Tem Tigue moved to approve Resolution R-03-2129.
Councilman Rice seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
PUBLIC HEARINGS:
4. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1397 -
Approval of a Special Use Permit for an accessory building on 10.272 acres
located at 816 L.D. Lockett Road, Case Z-03-007
Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1397.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Mr. Marty Stajduhar, 101 Williamsburg Court, applicant, was present to answer
questions of the Council.
Councilman Moore moved to approve Ordinance 0-03-1397 with the provision to
remove 1 d.
3
CITY COUNCIL MINUTES
APRIL 15, 2003
Mayor Pro Tem Tigue seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
5. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1398 -
Approval of an amendment to Chapter 6, Article II, Section 6-34. Records of the
Colleyville Code of Ordinances regarding the requirement to establish quarterly
reporting of alcohol and non-alcohol sales ratios, Case G-03-005
Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1398.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Discussion ensued regarding reporting periods and permitting process.
Councilman Hocutt moved to approve Ordinance 0-03-1398 with the following
amendment: Add to 1 a: During the first year of any license for on-premises alcoholic
beverage consumption issued to a new license-holder... In the event that no violation
occurs during the first year, then the business will only be required to report on an
annual basis, thereafter. Add to 1 g: In the event the City Manager finds a violation,
then the business will be required to comply with Section 1.a for the succeeding twelve
months.
Councilman Rice seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
6. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1399 -
Approval of an amendment to Chapter 1, Section 1.18.BA.b, of the Land
Development Code to expand the property owner notification for alcohol related
SUP requests, Case Z-03-009
Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1399.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
4
CITY COUNCIL MINUTES
APRIL 15, 2003
Councilman Hocutt moved to approve Ordinance 0-03-1399.
Councilman Rice seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
7. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1400 -
Approval to amend the existing electric franchise between the City and Oncor
Electric Delivery Company, to provide for a different consideration
Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1400.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Financial Analyst Collin Boothe provided an overview of the proposed amendment to
the existing franchise between the City and Oncor Electric Delivery company.
Mr. Rick Johnson of Oncor was present to answer questions of the Council.
Councilman Hocutt moved to table Ordinance 0-03-1400.
Councilman Rice seconded the motion.
Discussion ensued regarding the proposed amendment and potential for future
amendments.
Councilman Moore called the question.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
8. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1401 -
Approval to amend the existing gas franchise between the City and TXU Gas
Company, to provide for a different consideration and to authorize the lease of
facilities within the City's Rights-of-Way
Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1401.
5
CITY COUNCIL MINUTES
APRIL 15, 2003
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Mayor Pro Tem Tigue moved to approve Ordinance 0-03-1401.
Councilman Moore seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
9. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1402 -
Amending Ordinance 0-02-1324 and approving the amended Tax Increment
Financing (TIF) District Tax Project Plan, Exhibit "A", attachment 3
Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1402.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Mr. Jim Sabonis, First Southwest Financial, was present to answer questions of the
Council.
Finance Director Terry Leake provided an outline of the amendments to the TIF Project
Plan.
Discussion ensued regarding the establishment, status and value of the Tax Increment
Financing District.
Mayor Pro Tem Tigue moved to approve Ordinance 0-03-1402.
Councilman Hocutt seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
10. FIRST READING AND PUBLIC HEARING - Ordinance 0-03-1403 - Approval
of Amendments to Chapter 14 of the Land Development Code regarding
drainage, fire lane, construction plans and other engineering requirements, Case
G-03-006
6
CITY COUNCIL MINUTES
APRIL 15, 2003
Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1403.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
11. READING AND PUBLIC HEARING - Resolution R-03-2130 - Consideration of
appointment to the Library Board
Mayor Arp opened the public hearing and read Resolution R-03-2130 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Councilman Hocutt nominated Nancy Etchyson.
There were no other nominations and Mayor Arp called for the vote.
Council requested that staff advertise the open alternate position in June, which was
created as a result of Ms. Etchyson's appointment.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
12. READING AND PUBLIC HEARING - Resolution R-03-2131- Consideration of
appointments to the Celebrate Colleyville Steering Committee
Mayor Arp opened the public hearing and read Resolution R-03-2131 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Councilman Hocutt nominated Marcus Miller.
There were no other nominations for this position and Mayor Arp called for the vote.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
Councilman Rice nominated Dezann Korbuly.
7
CITY COUNCIL MINUTES
APRIL 15, 2003
Councilman Moore nominated Linda Newton.
There were no other nominations and Mayor Arp called for the vote.
Dezann Korbuly: Councilpersons Hocutt, Rice, Hendler and Mayor Pro Tem Tigue
Linda Newton: Councilman Moore
Mayor Arp declared Ms Dezann Korbuly appointed to the Celebrate Colleyville Steering
Committee.
Councilman Hendler nominated Linda Newton.
There were no other nominations and Mayor Arp called for the vote.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
13. READING AND PUBLIC HEARING - Resolution R-03-2132 - Approval of the
City Developer Agreement with Tommy Cunningham for the Sparger-Felps
Addition
Mayor Arp opened the public hearing and read Resolution R-03-2132 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Councilman Hocutt moved to approve Resolution R-03-2132.
Councilman Rice seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Moore and Mayor Pro Tem Tigue
Nays: Councilman Hendler
Mayor Arp declared the motion carried.
14. READING AND PUBLIC HEARING - Resolution R-03-2133 - Approval of the
award of a contract with O'Donnell's Landscape Services, Inc., for the Grounds
Maintenance Contract Mowing, Bid No. GMCM 1-03, in the amount of
$136,891.00
Mayor Arp opened the public hearing and read Resolution R-03-2133 in its entirety.
8
CITY COUNCIL MINUTES
APRIL 15, 2003
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Councilman Hocutt commended Parks Superintendent Tim Hightshoe for restructuring
the contract and and reducing the cost of the contract by over $100,000.
Mayor Pro Tem Tigue moved to approve Resolution R-03-2133.
Councilman Hocutt seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
15. READING AND PUBLIC HEARING - Resolution R-03-2134 - Approval of the
award of a contract with O'Donnell's Landscape Services, Inc., for the
Horticulture Grounds Maintenance Contract, Bid No. HGMC 2-03, in the amount
of $117,587.44
Mayor Arp opened the public hearing and read Resolution R-03-2134 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Councilman Rice moved to approve Resolution R-03-2134.
Councilman Moore seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
Councilman Hocutt commended staff for the maintenance and condition of the fields.
16. READING AND PUBLIC HEARING - Resolution R-03-2135 - Approval of a
Construction Contract with Municipal Utilities for L.D. Lockett Drainage Project, in
the amount of $230,757.00
Mayor Arp opened the public hearing and read Resolution R-03-2135 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
9
CITY COUNCIL MINUTES
APRIL 15, 2003
Councilman Moore moved to approve Resolution R-03-2135.
Mayor Pro Tem Tigue seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
17. READING AND PUBLIC HEARING - Resolution R-03-2136 - Approval of an
Agreement with Richmond Communications Group for the installation of voice
and data cabling in the City Hall and Library, in the amount of $74,800
Mayor Arp opened the public hearing and read Resolution R-03-2136 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Financial Analyst Collin Boothe provided an overview of the voice and data cabling in
the City Hall and Library.
Councilman Moore moved to approve Resolution R-03-2136.
Mayor Pro Tem Tigue seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
18. READING AND PUBLIC HEARING - Resolution R-03-2137 - Approval of a Tax
Increment Financing Agreement for Redevelopment Site NO.2 between the City
of Colleyville and Melvin & Martindale, L TO., (Town Center Development)
Mayor Arp opened the public hearing and read Resolution R-03-2137 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Community Development Director Barry LeBaron provided an overview of the Town
Center Development.
Finance Director Terry Leake provided an overview of the Tax Increment Financing
District Agreement for Redevelopment Site NO.2. and projected property income.
10
CITY COUNCIL MINUTES
APRIL 15, 2003
Discussion ensued regarding maintenance and landscaping of Church Street,
decorative street lights and maintenance of ponds.
Mr. Charles Hodges, 13642 Omega, Dallas, Melvin & Martindale, LTD., provided an
overview of the Town Center development.
Mr. Jim Sabonis, First Southwest Financial, provided an overview of the financial health
of the Town Center development as it relates to the Tax Increment Financing District.
Discussion ensued regarding responsibility for injuries sustained on public trails and the
first right of refusal.
Councilman Rice moved to approve Resolution R-03-2137 with the following
amendment: Add Section 2: That this Resolution shall be conditioned on passage and
acceptance of Resolution R-03-2138 by Melvin & Martindale, LTD.
Mayor Pro Tem Tigue seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
19. READING AND PUBLIC HEARING - Resolution R-03-2138 - Approval of an
Agreement between the City of Colleyville and Melvin & Martindale, LTD., (Town
Center Development)
Mayor Arp opened the public hearing and read Resolution R-03-2138 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Councilman Hocutt moved to approve Resolution R-03-2138.
Councilman Rice seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
20. READING AND PUBLIC HEARING - Resolution R-03-2139 - Approval of an
Agreement with 3M Company for a Theft Detection and Collection Management
System for the Colleyville Public Library, in an amount not to exceed $81,441.00
11
CITY COUNCIL MINUTES
APRIL 15, 2003
Council considered this item in Number 19 position.
Mayor Arp opened the public hearing and read Resolution R-03-2139 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Mayor Pro Tem Tigue moved to approve Resolution R-03-2139.
Councilman Hocutt seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
21. READING AND PUBLIC HEARING - Resolution R-03-2124 - Reconsideration
of City Council action taken on a request for a waiver of perimeter street
improvement requirements on Lot 3R, Block 2, Thompson Terraces, located at
5009 Thompson Terrace
Council considered this item in Number 18 position.
Mayor Arp opened the public hearing and read Resolution R-03-2124 in its entirety.
There was no one present wishing to speak concerning this item and Mayor Arp closed
the public hearing.
Mr. Jonathan Richard, 201 Rochell Court, applicant, was present to answer questions of
the Council.
Discussion ensued regarding perimeter street fees and the future development of the
area.
Councilman Hendler moved to approve Resolution R-03-2124 with the amendment to
reduce the street perimeter fee to $12,150.
The motion died for lack of a second.
Discussion continued regarding fees.
Mayor Arp recessed the meeting at 10:15 p.m. and reconvened at 10:40 p.m.
Discussion continued regarding the street perimeter fees.
12
CITY COUNCIL MINUTES
APRIL 15, 2003
Councilman Hocutt moved to deny Resolution R-03-2124.
Councilman Moore seconded the motion.
Councilpersons Hocutt and Moore withdrew the motion and second.
Councilman Hocutt moved to table Resolution R-03-2124.
Mayor Pro Tem Tigue seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the motion carried.
TABLED ITEMS:
22. CONSIDERATION OF ORDINANCE 0-03-1391 - Approval of a Zoning Change
from AG to R20 on Lot 2, Weston Ward Addition located at 6412 Ponderosa
Lane, Case Z-03-002
The applicant requested that this item be withdrawn.
23. STAFF REPORTS:
MONTHLY FINANCIAL REPORT
QUARTERLY INVESTMENT REPORT
There was no action taken on this item.
CITIZEN COMMENTS:
24. CITIZEN COMMENTS/PRESENTATIONS REGARDING ITEMS NOT ON THE
AGENDA
There was no one present wishing to speak.
ACTION/RESOLUTION:
25. DISCUSSION AND CONSIDERATION OF A RESOLUTION RATIFYING
COUNCIL AGENDA ACTION FOR THE MEETING OF APRIL 15, 2003 -
Reading and Public Hearing - Resolution R-03-2140
This item was not needed.
13
CITY COUNCIL MINUTES
APRIL 15, 2003
ADJOURNMENT:
26. ADJOURNMENT
There being no further business before the City Council, Councilman Moore
moved to adjourn.
Mayor Pro Tem Tigue seconded the motion.
Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue
Nays: None
Mayor Arp declared the meeting adjourned at 12:15 a.m.
APPROVED THIS
AYES,
DAY OF
NAYS AND
2003, BY A VOTE OF
ABSTENTIONS.
Minutes taken and prepared by:
Cynthia Singleton, TRMC
City Secretary
14
MINUTES OF THE
COLLEYVILLE CITY COUNCIL
WORKSESSION
MARCH 26, 2003
The Colleyville City Council Worksession was called to order by Mayor Arp on March
26, 2003, at 4:10p.m.
ROLL CALL:
Councilpersons Joe Hocutt, and Rich Hendler were present. Mayor
Donna Arp, City Manager Bill Lindley, Finance Director Terry Leake
and City Secretary Cynthia Singelton were also present.
Councilperson Brad Rice arrived at 4:20 p.m.
Mayor Pro Tem Ginny Tigue arrived at 4:40 p.m.
Other attendees included Mr. Charles Hodges of Melvin and
Martindale, Ltd.
2. Discussion and Consideration of Tax Increment Financing Agreement for
Redevelopment Site NO.2 with Town Center Development
City Manager Bill Lindley provided an overview of the proposed Town Center Tax
Increment Financing Incentive Agreement.
Discussion ensued regarding commercial development, zoning, entertainment uses
and the construction of Church Street.
3. Discussion of Proposed Projects relating to Town Center
There was general discussion of proposed projects relating to Town Center
4. Adjournment
CITY COUNCIL MINUTES
MARCH 26, 2003
There being no further business before the City Council, Mayor Arp adjourned the
meeting at 7:05 p.m.
APPROVED THIS
AYES,
DAY OF
NAYS AND
2003, BY A VOTE OF
ABSTENTIONS.
Minutes taken and prepared by:
Cynthia Singleton, TRMC
City Secretary
2
CITY COUNCIL ca@niB AGENDA BRIEFING
Il'X"::;
MEETING DATE: 05/06/03 CITY MANAGER
ITEM# :
RESOLUTION # :
7c
R-03-2142
DEPARTMENT HEAD ":reM
FINANCE REVIEW, N.A.
Previous Action: None
DEPARTMENT: COMMUNITY DEVELOPMENT
SUBJECT: Approval of the recommendation of the Sign Board
of Appeals for a variance to allow a 6' tall by 11'
wide by 22" deep sign at the entrance of Good
Shepherd Catholic Community on Tinker Road and
allow the existing signs to remain, Case G-03-007 -
by Consent
Reading and Public Hearing
Good Shepherd Catholic Community is currently constructing a new 36,000 square foot facility
on its 16 acre campus at 1000 Tinker Road. In conjunction with the new building construction,
Good Shepherd Catholic Community is requesting a variance from the sign regulations to
construct a 66 square foot institutional monument sign and to allow the existing 32 square foot
monument sign to remain.
On November 12, 2002, the plant manager for Good Shepherd Catholic Community contacted
the Colleyville code enforcement officer and was advised that an institutional sign was limited
to 90 square feet. The plant manager was also informed by the planning and zoning assistant
on the same day that two monument signs were permitted on the property so long as there
was a minimum of 60 feet of separation.
The plant manager subsequently placed an order for a block of limestone for the sign's
construction under the assumption that the 66 square feet was well under the maximum size
limit. No permit had been applied for at the time this information was obtained from City staff.
However, on April 15, 2003, a sign permit application was submitted and denied due to the
sign exceeding the size limit and the existence of a monument sign on the Tinker Road street
frontage. The applicant was advised to request a variance from the sign regulations.
Current Requlations
The maximum size institutional monument sign allowed by the current sign regulations is 32
square feet. The applicant is requesting approval to construct a 66 square foot monument
sign. The maximum height of a monument sign under the current regulations is 10 feet. The
proposed monument sign is only 6 feet in height. The current regulations only allow one
institutional monument sign per street frontage. The proposed monument sign, if approved,
would be a second monument sign along the Tinker Road frontage.
Agenda Briefing
Resolution R-03-2142
Page 2 of 6
Proposed Requlations
Over the past year, the City Council has been reviewing a proposal to revise the Colleyville
sign regulations. Included in the proposal is a revision to the size regulations for institutional
monument signs. The following is an excerpt from the proposed revision to the sign
regulations.
B. Institutional Siqns - These regulations provide for on-premises and off-premises Institutional Signs to assist
the public with the location of these types of uses.
1. On-Premises Institutional Sign: The purpose of an On-Premises
Institutional Sign is to identify schools, churches, hospitals or similar public
or quasi-public institutions. One On-Premises Institutional Sign per street
frontage shall be allowed on the premises where the institution is located
and in accordance with Table 7-1. All On-Premises Institutional Signs
shall be constructed as a monument sign as defined in this Land
Development Code. The maximum area, height, spacing, and setbacks of
an On-Premises Institutional Sign shall be in compliance with the
specifications contained in Table 7-2, provided that an On-Premises
Institutional Sign located within a commercial zoning district may comply
with the requirements of a General Business Sign.
Max. Area
45 s. f.
T
Lo
Institutional Sign
(On-premises)
a. Minimum Setback: Eight feet (8') from an abutting street right-of-way and thirty feet (30') from any
side or rear property line adjacent to another property.
b. Minimum Thickness: No On-Premises Institutional Sign shall be less than four and one-half inches (4-
Y;,") between vertical face planes.
c. Changeable Reader Board: An On-premises Institutional Sign may include a changeable reader
board area, provided the combined gross surface area does not exceed the maximum sign area and
provided that no more than fifty (50) percent of the maximum allowable sign area may be used as a
changeable reader board area. A permit is not required to change the message on a changeable
reader board. For purpose of this regulation, a changeable reader board may include an electronic
message area.
Analysis
The Good Shepherd Catholic Community campus has approximately 410 feet of frontage and
three driveways on Tinker Road. There is one driveway on Pleasant Run Road. There is an
existing monument sign adjacent to the Pleasant Run Road driveway. There is also an
existing monument sign located adjacent to the western most driveway on Tinker Road and
situated approximately 60 feet from the southwest corner of the property. The proposed new
monument sign will be located approximately 210 feet east from the existing monument sign
on Tinker Road and will be generally centered on the new church building.
As a part of the process for preparing the proposed revisions to the sign regulations, staff
conducted a survey of existing institutional monument signs and compiled a table showing the
sizes, heights and other characteristics of these signs. The information obtained from the field
survey is shown in the table below, which has been arranged in order of descending size. The
largest institutional monument sign in the table contains 98 square feet. It is not clear when
Agenda Briefing
Resolution R-03-2142
Page 3 of 6
this sign was constructed. Many cities have sign regulations that contain a formula to allow
larger signs in proportion to the lot size or the amount of lot frontage. Colleyville's regulation
for institutional signs does not contain this type of provision.
City of Colleyville -- Institutional Monument Signs
Address
Business Name
2600 Hall-Johnson Rd. Highland Meadows Christian Ch.
715 Cheek-Sparger Rd Colleyville Presbyterian Church
5800 ColleY\filleBlvd. Colleyville Elementary_~~ool
601 Glade Rd. Bransford Elementary School ~
3.~8 Glade_~d. Colleyville ChristianFello'^'ship____1
~901 Pleasant Run Rd. Pleasant Run Baptist ChLJrEb ...1.
3708 Glade Rd. Pleasant Glade Baptist Church !
5601 Pleasant Run Rd. First United Methodist Church
5300 Pool Road OC. Taylor Elementary School
1110 John McCain Rd. St. Mary's Orthodox Church
5304 Colleyville Blvd. First Baptist Church
2512 Glade Rd. . Pleasant/Glade Assembly of God
1901 Industrial~lvd. F<illgdom Harvest Church_'_
5312 BransfordRd. I Church of the Latter Day Saints
6300 Pleasant Run Rd. . Good Shepherd Catholic
6605 Pleasant Run Rd. Crown of Life Lutheran Church
1000 Tinker Rd. Good Shepherd Catholic
3801 Glade Rd. St. Mary's Romainian Church
3209 Glade Rd. ! Sonset Baptist Fellowship Church
Summary and Conclusion
Height
7.0
6.0
8.0
8.5
8.0
7.2
7.0
5.0
5.5
7.0
5.0
5.0
4.9
6.5
4.0
4.0
4.0
4.0
4.0
Size of Sign
Width S. F.
14.0 98.0
12.0 72.0
~l~~~
8.0 56.0
11.0 55.0
10.0 55.0
7.0 49.0
8.0! 40.0
8.0 j 40.0
8.()j _. 39.0
5.0 35.0
8.0 32.0
8.0 32.0
8.0: 32.0
4.01 16.0
3.0! 12.0
While staff may have erred in providing incorrect verbal information, a permit was never
applied for by the applicant for staff to formally review. Staff review of a permit application
would have discovered the oversized sign being proposed and that there was an existing sign
along that street frontage. However, even had the applicant applied for a sign permit and the
permit denied, the applicant could still have applied for a sign variance.
Staff notified all the adjacent properties regarding this sign variance. No written comments
have been received regarding this variance request.
According to Section F (5) of the Sign Code, the recommendation of the Sign Board of Appeals
regarding all sign variances is forwarded to the City Council for consideration.
At the April 21, 2003 meeting, the Sign Board of Appeals recommended approval of the sign
variance request with the following requirements: The lights on the sign will be turned off at
10:00 p.m., and that other, existing signs would not have to be moved.
Agenda Briefing
Resolution R-03-2142
Page 4 of 6
Recommendation
Approval
Attachments
· Site plan of church property
· Photographs of existing signs
· Letter from plant manager
· Sign permit application
. Drawings of proposed monument sign
· List of property owners notified
Agenda Briefing
Resolution R-03-2142
Page 5 of 6
Site Plan of Church Property
Agenda Briefing
Resolution R-03-2142
Page 6 of 6
View of new church building as seen
from Tinker Road
Monument sign located on Pleasant
Run Road
Monument sign located on Tinker
Road approximately 60 from the
southeast corner of the property
. '- -...... -"I 1 'r
~Moore,\' I' \
Siga B8f1I~ of ~p~! , (,
~ ~P.Q.B6x 185_ ) ~~' ,I , .J I- ,'/'
, / ' ~/o Community,DevelopmeIlt ' I 0 / r!
- ~ t' ~ /' Tom~~di~t ,'/ ( 1_ '''-., '/
, ; ~,\ ~ ' "~ 1/ .colleyville, TX 76034' , ,~,\' .J "
- " f' farish Centf] '''- ~ · r
/ i.lqOOTlnkerROad "" (\ " . i ,(j' I' ,\.;J
Colleyv~l~, Te~:is 76034 ( .~., ,\ I ; , ,
-/8~Jf~1-1387 \..c,. -, '. I I, ;~ ,- -,' .I,. / ,,/'f,. '\ " {'
!l17J.421-139;t' , pem:.c~ Moore, _ /., ,';~f " " (>c. /' '- ,J ,I
/' 'f'Ax817!'42~-4109 ),' '--'~ ",",- / / -'.\ ," .,,' " ,":'.
I (' \, ,- Wheti w~firSt re~an t~ Rre~deSign work f~t ,tl,1e Pqrtetdcher~ at our n~ '- '
Past!or~LAdmi~:~tTato,...' ':WOl;Ship sp~;,.We anticipated the n&d fqr a sign. . BaCk OllNove~r ,12;)2092, ,I J'
k ThereSa.1<hiralla.h, S,S~D {ca11td the'<;ityoJCon~e!'Pd,requeStedirifo~ti5>n-i~gfU"Q,ing the ~ocation, ~izc!l~
Sr. Dorothy Bggeriji, S:S.N,D, ",.~; gptPhic~ does it need8IHld~es~ e!,c" ,DD No~ h?t~~, t ~~ the'
'; clto/~d SPO~W1th,St~ve P.e~e7; ";110 ,m~ICate~ }?,,~,that ~~~ltutip~)Sl~ ~ould
, not exceed 90 squar~ feet per slde. My--descqptiOn of --the ~ ~ that It would.J,e ,
v. eithei, aboU)der, with ~ven faceS, or a pi~ df quarry funestone ill a stab form..:..."
, ~~her 9<>~me~ui~ appfo?ciIrnftt?ly T. bY(ll:(~~s 22'\ _'!~21;). We- wquid theu/ /
;;. CaJiVe OJ sandblaSt the thurcl):'s.name:nMo the. face o/the st.orleJ- GOOD ~'pHERD
, \CAta9L}C COMMUNI,~: . St~* said t~ the sign.~ be up ~ 10' qigh..(~" .'"
, -( - ~ -.' - - 1\ (, I ' \
- r;th~spoki,Mth Ian Le~,the ~ day, fro~ th~ dty arid ask'ep her'about,the-;ign-- / (
'. requ4'ernents:~. BeCa~ we already~hav~ a: sto~e s~o~ TiDk~ Ro~l'wante~./'-
. to. know if this woillQ ~ ~f$robleI1L f w~'-toldthatif.tp.e two\signs!were fit le~t 60'
\ apart, ther! wo~\be no froblem to hive ~o~~igns on\~e ~'- ~e~! ftontag~ ;\nG
because we are ~ ch~c.h, tl1at s~~ools and-ch'rr.che~,:caIlJx: ~v~ if neces~. J w~
, tol4 ofthef~~ pro~ess retp.l1nng'~e1eyatIon oftIw s~ ~~ smaIl plot of the . (~
~ lan~ t~t [ fo~ woutd~eed~o h;filled out~~ele'f~cal pennit would be I.~
'; neecled f9f the two lights for;,illlJI11IDatlon: Whenc.QJrr genera1 contraqtor went)o.:the
X" " .citf to ask fOr a pe~t Iast~ek, he was told iliB;1; tilt) sign c~'tt~ceed 32,s~feei~ ~, .
(\ - , ~ -' - _-../" ,-,...- - (/ \ I{, . ",-' ' ,"-, I \ ""\
I.. --\. >: I l -! ' " ).- -):y
We had movhfforward with{)ur design; 16cating and.piircbasingofthe limestone sigD,
eng~ermg the, foundat;ion for tHe sign (and haVe exceeded ~ hours b{ t~' and, .
, dolladiq p9fSllit ohhis en~U~~vor. FOlloWing-the prone iDfQIll)ation\~badrec~ived
from tli~ city"'m November zp02,we moyed ~~d - (,nly to' find out t~ . what ~we
"',, ".J' ; '- . \ . ". '. . or
~ .w~eJol9:<woul<tbe o~ay to install IS n9~ something :against th~ code.'. (
~ .
I'
~ ~ \, .
, '-
-/ I...
'.--'(
,
.J
r-
'\
~ ~r-
'I(
)
.-:
~~
}<'
)
/--'
)
j
i/'
\i ')
"
./
"\
'\
\
T
, "
...,
-~\
'--.
\:
)- ,
"-
l, '
....'
f-
I,
"- / - ,,1\ ~
Good Shepherd -Catholic Community
_. \ .' - I J --- ):~', . '. , ' ,L J
, ,
( -
('"I '
c' '-
-..,
r
,.....
, .J.
) "--,
\,.
r
"
C J
'. \ i
~I I
(
j/ y' ~
I
,
J .
I "
~ /
.~
r -
I
\
\
- ,
Appn 5, ,2003
i " , l
i , \
1\
" ~
../
.J
\ '-
J
r I
r '
"
'-
f "
.-/
. I
- /
( I
..J ,__
! /
\
0...- j ..J
/
I
/
)
~
,-'
"
',--
< .-
-~_.
'../,
I
"
c ,
J
(
J
,
" "'-
~
"
, J
"
_ f
_,r;
/-
j
".
,./
('
I
~I
!
~ -1"'
/"
0,
,f("
-"
,~
i
-'
/
,/ c \
("
I>.,
,~
'I
-I ). I \
I / I .
~ "'>. I "",' , ~- ", '" , ,- ',r
,--' I" \' - ,', ., l" (,' / " "
-f _ ' We' ask that our ~ Thnestone si~PaSicaI1y 6' taU by-\ 1 ~ wide b~ 22''' 'dee~ be
~~epte~_ by the city in ~O()~~fait~' We 'were foJo~ the, diiect~on of~cl~ ~n
/' ~I, ,; _ we mOved forward. 9~ ~~h, and I per~,JUlve wo~ed ~/~ ~1ty for some,
i 0 years ~ow as a go6~ Iie~hb()~. We request that~e be,.ghuit~ tlili; vanan~e for oUr
, ~stone sign. 'We also l:lsk,!hat we,IlQ,tbe obligiited ~o mOve tEe exiSting stone ,si~
onour~er~Ro~'t?ntrY.- ) ;-
, \ i j , -f: ~
:: \
(
\..
I ..... ,~ -
In gratitu4e~ - '
/; 'IM-, "riJ'-~j P,-~
-\ ,~,'-",
_,' I,' \',
) r
!)en Bur~ '
) plat;tt Manager' , / , ,~'
-:tJ9Qd Shepherd-CilthoJic ,cOrritnunity ^
" // J .' . ( I' ~ /-
, r
\.
7'
/
"'I..... ./
, I
I/'
.J::
;,
\
1 -
I'
/,
"
r
\
'(
/ '
,
/'
"
'KB:eI
,,,/
"
II \ - '(
::
, I
'-
L
'-
1 I
:~~
,J
<- ;,
;-
, c
i'
I
- \
\ -- '
"-
.J
"
,
I
'i'
\
,/
...
". '.
r L,
" f - (
" J
~
" ,
\
\\
" I
F
{
\'
:>
\. '-
, '-
I'
I
/'
I(
'"
/i'
v~
/~
/
'\
"'"
/
^'
- (';
'I
-'"
\,
'\
-l
'-
\
j
;J
\
"
, "
\
\ ,
_1:':: /
-.,
'\
"\
J
I
--."
_ /---
Ap~-Utl-U~ U4:~~~ dorothy 1 posey
817-577-7564
P.02
SIGN VARIANCE APPLICATION
Oate of submittal:
This application must be filled out in its
entirety for consideration and review
1- 1S"-tJ3
........................ ")i......... ....... .......... ......... ............ .11........ ......... ........................ ....
A. Applicant: (D()OO ~o -r~L.(f!.. lIJ~.JI.hfl . ,.;f )
Address: (bOO ~lt:.evc.. R.p ((EAl ~~{- ~-IpJT I,(,J~R.
~l.1..1::'1 u,uE ~ 740,4
8f7- 4'2. ( - 1387
Phone:
... .... .... ... .............1.. ............ ........... ..... ... ......... ............111.. '1'1 .... ....... 1..1... .......... II ....." ... .....
B. Owner of property:
Name SIfM~ Is ~d€' (~AJ(/) 4hrlf; 6,sijopJoSE'Pl{- P€lJtUe,
Utilt>'f~ D(DtS€" 4'F .g tJ~.:rff J ~
Address:
Phone:
8r7- ~~ - .3 300
........ ..... ......."".1.... 1."".1 .., ............ II .........." II.. ........ 1..1.. ..........".1 ... ... ... ... ... '" ... .... ... ....
C. Location of the Sign:
fOOO
number
-r; A.I K.~ f!.tJ.
street name
Address:
.. "' ........ .......1........" II ...... ..... ... .........~.. ...~.. ~... ......... ...... ~ ........ ~...~... ....... ~ ........... ..... ....... ...
D. Other information that must be submitted with this application:
./
Scaled site plan showing:
/1.
/2.
t/ 3.
V' 4.
Location of any buildings, structures or tract to which or upon which the
sign is to be attached.
The position of the sign in relation to nearby buildings, structures, or other
related signs.
dimension of setbacks, building lines, distance between the proposed sign
and street, distance of proposed signs and property lines
drawing of proposed sign including height, width, and area.
./
./'
Detail plan of the actual sign.
A detailed letter indicating why your sign can not meet the requirements of the
sign ordinance as well as a description of what your intentions are in placing
GoP~ Citr-r(oLfC- C"",,^J,J,'n7 1-8-03
( Lu E'D cC-~ 1; M. EO 1O,J1!' - A.." ~8J-r/rt- Si~ N) . f 1S01J je.fF. 3
&OPOSE'D .. .. t 10, 7 f,;,JS (/\J 2/) 370.e4- )
[ 4 n~o I
/ V
(.fiftE of ;5 liP tJ ) 7
71 "
-()
r
: fp,O
!ftol15Jf
~ /'--0
,~D
~11v- .
~ 6{\t s
6cO ~ D 1-1 L-- J,J ,11 ____ ----
c.J\ r Ie D*^'^ ~ /'----
~ B.~fo;o
)r (r- ~c~
~u~p..
,I
I
Y]/O
j:f
~
/'
/'"
j~
(j5jLl-
817- 42-1- /38 7
/'
I
i
r
'.L
==~~~"--~~t \j _~_
.------.--- ~JU-b
---------
~-
:~~-
-- ?G-~. - .T~2_=:J
---~-itt1t=~ ___
. ,
f;Q/1tvltNI3[Yj
".-- ----.----.---4--~-..____._____..- __ .____._ ..__
_.~. ~---'---------;...-,----...._---_._____ _v___. ..." '_._
.-.-.-.-!
_. ..... .-..----.---...... _..-. .----------.-----..j
",-,'--" ..,-~'-~~_.----'_._-._._._~._---_._--
...... --- )
...
Hr-r<:-LIO-lQ':'
~: ,!~~JJ fttLtW
~t~11 ~ lll'1 ~RMHto~"
~\: I'-.l: tltll~\ f)HlbN
h~t\tI"F4f. ~lhl
(. ( (<'IN
.
-v-
\:
II
"~
;0
o
~ .
-
IHU
1O~:~6 JIM BRANSFORD ARCHITECT
--- - -. --". '''- ---..,..,
p.e1
p.a2
817 834 1667
~1. (" . (o68~ '
11~\ .._~~~.i~__~,
~_.,..~--.
16 .
. "
~
... . .
, 1
,-.. J"', .
.. I ......
. " ~
. J. \
, .
~
o
".. .', I
~\J
I'?
3 '-
7'k'.
fll-1.. c^,v1rt
WI II t(~ H .s r1\tN(,T It
.4^DIIT Aft€-"
. fL"<=fMt.N r ot:
<'t"ONE-
Jll-=ltI'.~
2
&1 ~ 'I"
L-J ~ L;. Q.C.
~ '-$ "
,I
~ FOOTIN ~
,
!D~ MDN II ~tN~~~" SIGtjJ
DE-TAl L
. b .
&A l.. f,.: ~ II ~ 1'. (J If
"
..~~
~"
~rUl 0'" . N
~ .c. . CD~ N C> "
~ c..l - ~~ .., I ..
8Eti ~. CO t.
\ t- t ,., ~ - N
QI E;;;; <(€ to Q
t::Q~ 0
0 Z G>
OUIl 'E~ ~
a~~~~ a. .g =a ,91: ti
(5U mO CD
~~V7~~ ~ c:u. "[
CL(j 4J I,S) '0 !! a.
~ ~ '0rD (j en
"0 E
"-
CD :::;
.c
i
.J::. :{
~. 'f/)
(" "0
0
0
.:z I ,C) I
I
r
\ ~ '
----\
" 1
,I
n___'-
---7
,
I
\
\ .
i;
i
!
5'
--
II
.
e
.....
: :
;.
tj
tL
i I
<
.C:
Q
~
>
41
ill
;;
:3
o
en
::1- .
i !
I.....
I
j
~.
i
. ~.
,;7\
.: I
c
o
'B
~
.
i
! .
l
'\
i
I
c:
o
ij
Gl
en
..,
a
r C\.G
-.& ~
a
-J
C'Q ~
\
""t: ~l_
~!
... - .. -
$-
I
b
C')
Jf~
\ ....
l-v
:J \- c
......
~ III
<\: ~ .0::
0
'""
~ ~!
0ij]
;-: ~
&-'1/
.'"
-----
~
;t.
~
.(:'
J
-J
~~,'
~~
.:s
i c..---~
~~
i ~ ~(
o 0 ~
~ N
III * >-
. rd 0 ~
<: Q) .~ <
.2 co e
tlg [L.
3 G> ?:-
aa: .~
"So E
~ l! E
.~~ ~ ~
:E(i '0 ~
.~~ s= "0
- "0) Ci c:
"C 'C: U tV
; 0 _
eo -e.~
4)5 ~~o
liic: -Q.Q.u;
'-~Q)a.cu
~i ...~=.~
~ "C cu 'i _
~-5-e-g.i .
'2C:O'~Nts~.
.- Q) '" C') III 0
ft!~g~~~
f<llca....*8.!!!
I;:OS=o.., 5
.r::~u-eu"O....
-o"'O'~eIl0
.~-c8.lPe1ijn
"C.~ 0 ~~ 2 III
8. Q)tVou::
Q."O 'O's= "'" _ c:
':iliiliU~~8
0"0 lUc::2_
GlNlPlU'i::J~
.855~e2'5
-oE=OQ)'C:
:S:"OO~ C:O
~-~I'JJ'Ooc
CDIllCU"'C:U;._
i:1C:lP<Iloc:
iJj .r:: .c: 0 '8 iii E .gt
W UCl 0::1:=..
0= i!i:u c: lP 5
b u(,ol)~5'c:
CD. c: 1:: cu
z 1:o<llOtScu):(
I- o:;a,uo..CU-gCD
U 0.. t:' :!:: cu .~u ....
W'CDIUE,c:.ec:o
., .r::~Ol-o..__
o 1-1-.. .n
g: "':N"'.
"C
:0
.S
<II
E
~
4'5~~ l
~>:',' ~:. I~. I .... ,T}..{ ..) \
..... ..." ~ "'~:~':.t'~'" ~ ~
" . '. "'~--J t1. '<.... "T-;> t Q
6;;t~~1)'t ~'" \... '.i.!
Q~' J;,.<:'-' I~-,~,,,? ,:-\.;: I
...,. "., . <. ....,. . I dtt"b C'
~ "'rr~ _or ...., "'\"'. .
' . \:~ '''j~l'/>8:. I>~~' ;;:.~ _
r.;~ ~<~ . // ... b." lit
.\::J ~ '~:"~.'~V'. S ','"" j,.":--'S./l (
.\ ~, , "..-,,'. ',cO,. ",'9' ",...
~" ~ '\, "'#.,:J:;',; -i':.:j,':>
-.. \C~ "oli:c;",,,.
~~,~
~1 .
~~~
~~v~ .
~~\~ .
~W!~
t'-- ~ ~~~ \
. ~~
\ . "'1
il)
\'
\
i
J
1Il~:t
~ '2 ~
'= ::JI-
8E..-
~ ~.~
aU=
[L.gS
o
-5
,IV
U
~
ell
.r;
a.
Q)
.r;
C/)
'1J
o
o
C>
'~
"-l
~
u::
Q) )(.
... ..
.- I-
~~
<5
~3=
.2:5
11)1.1..
c:
10
....
m
E
:.::;
~. ~ ;
~ ~ ~
~ rb
o G>
Z ni
U C
III
'0"
0.:
List of Property Owners Notified
Burrow, Marian Alice
6405 Pleasant Run Road
Colleyville TX 76034
Burrow, Darrel D Etux Marian A
6405 Pleasant Run Road
Colleyville TX 76034
Dolan, Thomas D Etux Edna
6317 Pleasant Run Road
Colleyville TX 76034
Delaney, Joseph P
800 W Loop 820 S
Fort Worth TX 76108
Vencill, Robert Etux Shirley
6215 Pleasant Run Road
Colleyville TX 76034
Westbrook, Sandi & Chas Gorena
909 Tinker Road
Colleyville TX 76034
Denman, Darin Ja
911 Tinker Road
Colleyville TX 76034
Kepp, Nancy J
1005 Tinker Road
Colleyville TX 76034
Davis, Gary D Etux Mary Ann
6400 Pleasant Run Road
Colleyville TX 76034
Davis, Ullin D & Patricia
The Davis Family Trust
6316 Pleasant Run Road
Colleyville TX 76034
CITY COUNCIL
ca~", AGENDA BRIEFING
iC'x~$
MEETING DATE:
ITEM # :
RESOLUTION # :
05/06/03
7d
R-03-2142
CITY MANAGER j
DEPARTMENT HEAD j
FINANCE REVIEW j
Previous Action: None
DEPARTMENT: COMMUNITY DEVELOPMENT
SUBJECT: Approval of the recommendation of the Sign Board
of Appeals for a variance to allow a 5' by 10'
changeable letter wall mounted "reader board" sign
on the side of the Sunbelt Gymnastics building
located at 4701 Bransford Road, Case G-03-008 -
by Consent
Reading and Public Hearing
Sunbelt Gymnastics is located at 4701 Bransford Road at the intersection with Centerpark
Drive (see Attachment 1). CGS Signs is requesting a variance from Chapter 7 - Sign
Regulations, of the Colleyville Land Development Code to construct a 50 square foot wall
mounted "Reader Board" sign (see Attachment 2) with changeable letters to be used by the
owner to announce events at their facility. Currently there are no provisions in the sign
regulations to incorporate a changeable "reader-board" in to an attached wall sign. The
current regulations allow changeable message boards as a portion of a freestanding Multi-
Purpose Monument sign.
Current Requlations
Wall mounted signs are permitted for General Business purposes limited in size to "two times
the length of a building fa9ade. This building is 197 feet in width, therefore single or multiple
signs as large as 394 square feet are permitted on this wall. The existing "Sunbelt Gymnastics
Academy" sign is only 90 square feet and the proposed "reader board" sign is 50 square feet.
The combined area of 140 square feet is well within the 394 s.f. allowed by the current
regulations.
The proposed sign regulations currently being considered by the City Council limits
changeable reader boards to fifty percent of the area of a monument sign. There is no
provision proposed for changeable reader boards attached to the side of a building.
Analvsis
The applicant initially requested approval to place the changeable message board toward the
northern end of the building (see Attachment 3). However, at the Sign Board of Appeals
meeting on April 29, 2003, the initial location of the sign was denied. The Sign Board of
Appeals has recommended approval of the sign variance request, provided the sign be
situated under the existing wall sign on the east side of the building as shown on Attachment 3.
Agenda Briefing
Resolution R-03-2142
Page 2 of 2
According to Section F (5) of the Sign Code, the recommendation of the Sign Board of Appeals
will be forwarded to the City Council for their consideration. Staff notified all the adjacent
properties regarding this sign variance. No comments have been received regarding this
variance request.
Recommendation
Approval as recommended by the Sign Board of Appeals
Attachments
· Location Map
· Drawing of proposed sign
· Photograph of building facade
· List of property owners notified of variance request
_..____u_. ~CF-~
[\!'1D
.
5tU
\1\
~s
1
I
2."79 .
IEl
I AC
Hl 2:<
2.9 AC
{.
fR 21'\ Tn ?Y
1 AC 2 At
.J
:Lr]
.11'.1 '!IO~'U (;1'
23
22
21
,.
,7
~ Cf\~G1Z
AOON ~V
_. J
I
~
TRACT A
'"'
'"
TA 20
10.0 AC
~ _ 'ZO~
o p"C.
8.B.e'SuPI/E{
(1.z0G
1R tG
1.'" AC
TFl 19 .~19 Ae
"
'"
~~
Ii.!
1R 182 1."7 N:.
TR lC1A
1. 928 AC
TA
ICI
0.:
"'
.
.
19 :
.
4A
fR Ie
J.l AC
1
.754
AC
, ~.
~.
g 5&
o
,.,
'"
.-1
,..,
f [\DD
g 1<ROGGR
u
1l!J.B25 .
._u_u_u_~
Tn 28
1.1lI AC
TR 2U fR 7....\
IACt.2AC
TR 2H
I AC
Tn 21]
1_3 At
TR :2C
1.111 At
TR 7'"
1.2 "c
d~,l
ou~b '~029 .
TR 2lL TR 2E
2.14AC I.C!lAC
,
6.50 D
BLACK
DR
~~1~-
I [\0
flR~t'lD
TR 2V
2.9 At
IA
7.59? II
.3'l'
-
· E
~
TR 2/\
1.\ AC
: -"I..
I ~_:
'"
.,
::;
~~
TA ;?K.
4.3 AC
It r p. Fl( .------------
r:t'l'fG 'N '" 1 c::
C [\01> ~/ 8.9'.' . 'Z ,,)
':g:~~o'\)\JD~ ,--- . I
~ _ ,'Iii .
~------'(o-!? I, ""I \ t'
~I ,.'I. '.' l' - -- w~__ '
. ' / /', ----------.:
TR 2L
".0 a
T" 10
Attachment 1 - Location
Map
..a
0 ~
..., a-
CD
~ ....
....
u CD en
.... ..
-- CD
- CD ..
..
~ CD
CD ...I
a - :) CD
- IT CD
C 0 :)
a- U'"
E a ..
N ~ a
~
>- CD .-
I ~
- .-
C) ..a E
a CD
C)
- CD
.
m .
00
~ c
..a a
.c
C U
::)
'"
.
-
0
-0
Attachment 2 - Drawing of Proposed Sign
Attachment 3 - Photograph of Building Facade
Krivsky-Bartusiak Inc.
3220 Clear Fork Drive
Hurst, TX 76054
Grand Prairie No Five Inc.
Dba Eagle Transmission
2317 Clearview Ct.
Lewisville, TX 75057
Richard & Terri Ervin
1155 W. Wall St., Ste 101
Grapevine, TX 76051
Dasta Inc.
3121 Glenmere Court
Carrollton, TX 75007
H & R Buckner Enterprises Inc.
4616 Colleyville Blvd.
Colleyville, TX 76034
Cindy Boykin
GGS Signs
7348 Tower Street
Richland Hills, TX 76118
Case G-03-008 (Notices dated: April 22, 2003)
According to the last published Tax Record, the above individuals own property in near proximity
of the sign variance request. I certify that the parties listed above have been notified of the
proposed sign variance request.
Jan Levy r;I-
Planning ;~Oning Assistant
CITY COUNCIL
cae<ll AGENDA BRIEFING
'ex",$
MEETING DATE:
ITEM # :
ORDINANCE # :
05/06/03
8
0-03-1403
CITY MANAGER !
DEPARTMENT HEAD !
FINANCE REVIEW I
Previous Action: 04/15/03
DEPARTMENT: COMMUNITY DEVELOPMENT
SUBJECT : Approval of Amendments to Chapter 14 of the Land
Development Code regarding drainage, fire lane,
construction plans and other engineering
requirements, Case G-03-006
Second Reading and Public Hearing
Standards for concrete streets have been modified from 3,000 p.s.i. specifications to 3,500
p.s.i. concrete in the attached proposed amendments to Chapter 14 of the Land Development
Code.
First Reading and Public Hearing
Chapter 14 of the Land Development Code contains engineering design standards for public
improvements, such as water and sewer lines, street projects and drainage facilities. Over the
past several months, Community Development and Engineering Department staff has
reviewed the regulations in this chapter in response to repeated questions from developers
and their engineers for clarification and/or interpretation. Additionally, state and federal
requirements that have recently been imposed on municipalities need to be incorporated into
the applicable sections within these regulations.
Staff solicited and received comments and suggestions from area engineers and developers
who responded to our mail-out on December 13, 2002 advising them of the proposed revisions
and requesting their input. Many of the comments and suggestions they offered have been
incorporated into the proposed text changes.
At the March 4, 2003 Pre-Council meeting, the discussion regarding the sewer service line
repair policy resulted in a directive to staff to include the appropriate regulations in the Land
Development Code to clarify the inspection procedures associated with new sewer line
installations. Language has been added in Section 14-165.G to require a video inspection
upon sewer tap installation.
Also, at the March 4, 2003 Pre-Council meeting, staff was requested to compare the cost and
technical differences between concrete with a 3,000 p.s.i. strength and that with a 3,500 p.s.i.
strength. Staff contacted a local concrete supplier who indicated that the cost difference
amounted to about $1.50 per cubic yard more to go from the 3,000 p.s.i. to 3,500 p.s.i.
concrete. This represents a cost differential of approximately 3% more to increase the
concrete strength specifications for a typical subdivision street. There is no additional labor or
Agenda Briefing
Ordinance 0-03-1403
Page 2 of 4
material costs.
Charles Jackson of CMJ Engineering recommends our going to 3,500 p.s.i. concrete for
roadway construction projects due to the extended life expectancy of an average street.
According to the information obtained by the Colleyville Engineering staff, there would be no
issue with brittleness of the concrete due to the increased concrete strength.
Staff also contacted our neighboring communities to determine their concrete specifications
and these are shown in the following table. The specifications contained in the attached draft
version of Chapter 14 have not been changed, pending direction from the City Council.
RESIDENTIAL STREETS (Concrete)
Thickness Strength Rebar
lin\ Insi) (size & sDacinD)
Colleyville 6 3,000 #3 @ 18" centers
NRH 5 3,000 #3 @ 18" centers
Hurst 5 3,000 #4 @ 1 8" centers
Euless 6 4.200 #4 @ 18" centers
Grapevine 8 3,600 #3 @ 24" centers
Bedford 6 3,000 #3 @ 1 8" centers
South lake 6 3,000 #4 @ 24" centers
Keller 6 3,600 #3 @ 1 8" centers
A brief summary (Attachment 1) outlining the most significant changes being proposed for
Chapter 14 is included with this memo. One of the most visible changes being proposed is the
manner in which the chapter is organized and presented in order to make it is easier to find
certain topics through better paragraph notation and re-numbering of the various sections.
The original system generated numerous complaints regarding the difficulty in navigating
through this chapter.
Attachment 2 is a copy of Chapter 14-Engineering Design Standards of the Colleyville Land
Development Code that has been marked to reflect the proposed changes. Text indicated as
"strikethrough" is proposed for deletion and text shown as "bold/italics/underlined" is proposed
to reflect new regulation.
Recommendation
Approval
Attachments:
. Attachment 1 - Summary of proposed changes to Chapter 14
. Attachment 2 - Copy of Chapter 14 showing proposed revisions
· Ordinance 0-03-1403
Agenda Briefing
Ordinance 0-03-1403
Page 3 of 4
Attachment 1
Summary of Major Changes to Chapter 14 of the Land Development Code
1. The "section and paragraph notation" is being revised to assist in better organization of
the regulations and for ease in making amendments in the future.
2. The term "Director of Public Services" is being changed to "Director of Public Works" to
be consistent with the term used in the Colleyville City Charter.
3. Section 14-120 - The changes are proposed to clarify the regulations regarding
construction specifications and City-Developer Agreements.
4. Section 14-125 - added language to Paragraph N to reference street sign standards.
5. Section 14-125 - added Paragraph B to address the minimum number of copies of
plans a developer is to submit.
6. Section 14-125 - The changes are proposed to clarify the regulations regarding
construction plan requirements. New paragraphs are added regarding storm water
pollution prevention requirements and to require a street sign plan.
7. Section 14-135 - A change from 3,000 p.s.i. to 3,500 p.s.i is proposed on commercial
and industrial driveways. A minimum distance for a driveway from a storm water inlet is
included, and the driveway construction standard is changed to match the construction
drawing detail. Substantial requirements for fire lanes have also been added.
8. Section 14-137, Paragraph I - the outside turning radius on a fire lane was changed
from 54 to 50 feet.
9. Section 14-145 - added Paragraph A to require the installation of street signs by City
work crews, but only after the developer has paid for the installation costs. Also, no
building permits to be issued until all street name signs have been installed in a new
development.
10. Section 14-145 - added Paragraph F to allow the installation of custom street signs with
the approval of the Director of Public Works, provided there is a written agreement for
maintenance and replacement.
11. Section 14-145 - A change to the street sign regulations will reference the Texas
Manual on Uniform Traffic Control Devices.
12. Section 14-150 - Language is added to clarify the applicability of sidewalk and pathway
standards.
13. Section 14-160. Language is added (Section E) to provide spacing requirements for fire
hydrants.
Agenda Briefing
Ordinance 0-03-1403
Page 4 of 4
14. Section 14-165 - added Paragraph G.8 to stipulate that all sewer service lines must
connect to a public main line and not to a manhole.
15. Section 14-170 - Changes are made to paragraph G regarding culvert design.
16. Section 14-170 - Changes are made to paragraph H regarding bridge pier design.
17. Section 14-170 - Changes are made to paragraph I regarding channel designs.
18. Section 14-170 - Changes are made to paragraph C regarding single-family coefficient
of runoff and paragraph J regarding detention design.
19. Section 14-180 - Changes are made to paragraph A regarding preliminary drainage
analysis guidelines.
Attachment 2
Chapter 14 - Engineering Design Standards
Showing proposed changes
Colleyville, Texas, Land Development Code
Proposed Revision 4/15103
Section 14-100 Purpose of This Chapter
The purpose of this Chapter is to establish minimum standards and construction details for all public facility
improvements.
Section 14-105 Authorization for Idoptlon ofl ili"ls S,haoter
The regulations contained in this Chapter have been adopted under the following authority:
.:+.A.Chapter 212 - Municipal Regulation of Subdivisions and Property Development of the Texas Local
Government Code, which authorizes a municipality to adopt rules governing plats and subdivisions of
land within the municipality's jurisdiction.
~.B.Chapter 51 - General Powers of Municipalities of the Texas Local Government Code, which authorizes a
municipality to adopt ordinances, rules, or police regulations that are for the good government, peace, or
the trade and commerce of the municipality.
a.c. The Home Rule Charter of the City of Colleyville, which authorizes the City Council to exercise all powers
granted to municipalities by the Constitution or the laws of the State of Texas.
Section 14-110 Applicability 01 Ihis Chapter
The provisions of this Chapter shall be applicable to all public improvements owned and maintained by the
City of Colleyville and to any semi-public improvements owned and maintained by a property owner's
association that are intended to serve and function as a public improvement.
Section 14-115 Variances and Appeals
A. The Director of Public Servi€l9~ Works may consider an alternative proposal of a regulation contained in
this Chapter in order to achieve the best overall design. When considering such a proposal, the Director
of Public Ser\'i€le~ Works shall determine that the approval, disapproval or modification will not be
detrimental to the public safety, health, or welfare or injurious to other property and is consistent with
sound engineering practices. The applicant shall provide information to support a claim that the public
interest may be better served by an alternative proposal.
B. Any person seeking approval of a development may appeal a decision of the Director of Public S8P:i€l8s
Works regarding the regulations contained in this Chapter by using the procedures described in Chapter
1 - General Provisions of this Land Development Code.
Section 14-120 General Conditions i ,II"~ "
H.5.A "COG &. TXDOT" SPECIFIC.~.TIONS
A. "COG" and "TXDOT" Specifications - All drawings and details contained in Chapter 15 - Public Works
Construction Details which include references to "item numbers", "specs" and "types" shall be governed
by the latest version of "Standard Specifications for Public Works Construction, North Central Texas" of
the North Central Texas Council of Governments ("COG"), with all amendments thereto, and shall
Chapter 14 - Engineering Design Standards
Page 14 - 1
Colleyvi/le, Texas, Land Development Code
constitute the technical specifications, except as amended by this Land Development Code, and made a
part thereof, but not physically bound within this document. Streets shall be designed in accordance with
the most current edition of The Texas Department of Transportation's Highway Design Division
Operations and Procedures Manual, AASHTO's A Policv on Geometric Desiqn of Hiqhwavs and
Streets. and the Transporation Research Board's Hiqhwav Capacity Manual.
14.5.~ ^CCE!PT.~~JCE! OF IMPROVE!ME!~JTS
B. Acceptance of Improvements - No public improvements shall be accepted by the City or its
representatives, unless and until such improvements conform to this Land Development Code and all
other applicable standards as prescribed by the City of Colleyville. All streets, alleys, sidewalks,
drainage-ways, siqnaqe. water and sewer lines and all other public improvements shall be designed,
placed and constructed in accordance with the design criteria contained in this Land Development Code.
H.5.C PL.I\P'j RE)}IE'}'.' AND INSPECTIOP'j FEES
C. Plan Review and Inspection Fees - Prior to the acceptance by the City of any public improvements, the
developer shall pay the City a plan review fee and an inspection fee as follows:
a..1.P\;IQli€J 'P.'@rks Enaineerina Plan Review Fee - 2% of the actual cost of the public improvements
9.2. P\;IQli€J 'fI.'erl(s Enqineerina Inspection Fee - 3% of the actual cost of the public improvements
14.5.D CITY DEt'ELOPER ^GREEME~jTS
D. City-Developer Aqreements
1. Requirement amil \(l.<ai\'sr P."'fiJ':isffm - When it is proposed that the City will share in the costs
with a developer for the construction of public improvements. no Ne public improvements shall
be constructed within a development, unless and until a City-Developer Agreement has been
approved by the City Council. Where the public improvements are a requirement of a
subdivision plat approval. the +Re City-Developer Agreement shall be submitted to the City
Council for approval by the City Council at the same time as the ~ Plat plat submittal, or as soon
thereafter as practical. \,\..'l;1e~El Re p\;lQli€J parti€JipatieR ef p\;lQli€l fa€lilities is prepeseel aRel '.'Jl;1er8 tl;18
Qi~e€Jter ef P\;IQli€J Ser\'i€les Ras FRaele re€JeFRFR8RaatieR t@ tl;1e appre'/iR~ Qeay ef a €Ie'.'elepFR8Rt tl;1at
Re City Oevelep8r 1'.~reeFReRt is R8€J9ssap/, tRe City Qeveleper ^~reeFReRt FRay Qe waivea. (0-00-1261
/12/19/00)
2. City Participation - The City may share in the costs with a developer for constructing public
improvements relating to a development, provided a City-Developer Agreement has been approved
QY elR ereliRelR€J9 tl;1at l;1as Qrile:m aaepteel by the City Council in accordance with this Section. The limits
of City participation shall be expressly established in the agreement at a level not to exceed thirty (30)
percent of the total contract price. Under the agreement, the developer shall construct the public
improvements and the City shall participate in the costs. Where a developer is requesting City
participation in the construction of a public facility and the total participation cost by the City exceeds
fiftS8A tI;1S\;ISBAa ($15,000) twenty-five thousand ($25.000J dollars, the procurement procedures
specified in the Texas Local Government Code for public improvements shall be used by the
developer. All records to the developer's cost of constructing the public improvements shall be
maintained and made available for inspection by the City. (0-00-1261/12/19/00)
3. Construction Plans - It shall be the responsibility of the developer's engineer to prepare all
engineering construction plans and contract documents for construction of the project for the use of
the City and the contractor. (0-00-1261/12/19/00)
4. Performance Bond - Where a City-Developer Agreement has been authorized, the developer shall
execute a performance bond for the construction of the public improvements which shall include any
City participation to ensure their completion. (0-00-1261/12/19/00)
E. Authorization to Proceed -
Chapter 14 - Engineering Design Standards
Page 14 - 2
Colleyville, Texas, Land Development Code
i. /1.l:IthfJ."''':lstfBf-I tB RI';f)see€/ QR rsr9je€t~ R@t r9€ll;lifiR!1j a City Develerser ^!1jr88~eRt, the The developer
may proceed with the construction of the public improvements after the City has issued a letter
authorizing the developer to proceed with the construction, provided the engineering construction
plans have been approved by the Director of Public ~ervi€es Works. All construction shall be in
accordance with the applicable sections of this Land Development Code. The developer may select
his own contractor subject to the contractor executing the necessary bonds with the City and payment
of the inspection fees required for each portion of the public facilities. (0-00-1261/12/19/00)
Section 14.125 Construction Plan Requirements
The purpose of this Section is to specifv the minimum construction drawinQ requirements for all
public improvement projects. includinQ public improvements associated with a proposed subdivision
or commercial development. All construction plans for public water, sanitary sewer, street, drainage and
traffic improvements shall be designed, signed, sealed, and dated by a Registered Professional Engineer
licensed in the State of Texas. aRE;! aE;!Rsre te tREl re€ll;lire~9Rts sf tRis ~eetisR. All construction plans or
drawings must be accompanied by a Geotech Report signed, sealed, and dated by a Registered Professional
Engineer licensed in the State of Texas. Plans and drawings shall adhere to the requirements in this
Section and be furnished in the fellewiR!1j format GlR8 eeRtaiR tRe 9Ie~eRt~ listed herein:
A. General Requirement - No construction of anv public improvement shall commence. unless and
until the construction plans for the proposed public improvement has been approved bv the
Director of Public Works or desiQnee.
B. Number of Copies - The developer. or developer's engineer. shall submit the minimum number of
copies required bv the Director of Public Works to distribute to the various Citv departments to
adeQuatelv review the proposed improvements.
4.C.Cover Sheet
a.1- project title
9.g property legal description, if applicable
G.J.. ~ citv name
G.~. vicinity map
8.5. owner, engineer, and surveyor name, address and telephone number
f. ~. project title in small print placed vertically along the right border
~.Z. sheet index
R.~. signature block for City approval
2.D.Copv of Current Plat - When construction plans are related to a new subdivision or a commercial
development,arsrslieaele, a copy of the current plat shall be bound with the construction plans. The
signed plat shall be bound with the as-built drawings.
3.g.Drainaqe Area Map - The drainaQe area map is critical to all drainage desiQns. since the ultimate
lavout. sizing and hvdraulic analvsis is dependent upon a thorouQh review of the proposed
development. This map should be accompanied with all drainage calculations. The Drainage Area Map
must show the phvsical features of the site that either exist or are proposed. including aU the
existing and proposed contours, existing and proposed storm sewers, and/or other drainage facilities.
Commercial projects should include the locations of buildinQs. flatwork and pavement.
4.E.Site Plan - The developer of a commercial project shall submit a site plan indicating the location and
width of all proposed and existing street and driveway approaches noting the back-of-curb radii.
i.G.Utilitv Plan - This drawinQ shall indicate iR8ieatiR!1j the location and size of all existing and proposed
water and sanitary sewer lines with adjacent existing or proposed top of curb grades. A*;e s~how the
location of all existing and proposed fire hydrants adjacent to the site including the maximum coverage
radius of each as outlined in later sections of this manual.
i.H.Plan and Profile Sheets - Plan and profile drawinQs shall be required for roads, sewers, storm sewers,
Chapter 14 - Engineering Design Standards
Page 14 - 3
Colleyville, Texas, wnd Development Code
channels, flumes, and water lines twelve (12") inches in diameter and larger. Stationing shall be generally
left to right and with stationing beginning at the downstream end for all sewers, storm sewers, and
channels. Stationing shall be included on the plan view as well as the profile for all roads, water, sewer,
storm sewer and channel sheets. Elevations shall be calculated and provided iA on all profiles as
indicated below.
a.1- Straight grade - provide elevations at a maximum interval of 50 feet.
9.~. Vertical curve - provide elevations at the beginning and ending points and at a maximum interval of
25 feet in between.
+:.I.Plan & Profile Sheet Size - Plan and profile sheets shall not exceed twenty-four (24") inches wide by thirty-
six (36") inches long. Horizontal scale shall be one (1") inch equals fifty (50') feet or larger, i.e. 1" = 40'.
Vertical scale shall be one (1") inch equals five (5') feet or larger.
i.J.Details - Drawina details shall be included with all construction olans to clarifv orooosed
construction soecifications and said details shall be consistent with Chaoter 15 of this Land
Deve/ooment Code. fer im~FevemEH:Jt~ ~re~e~e€! fer €!e€!iQati@A te tRe City.
9.K.Plottinq Drainaqe Features - Appropriate hydraulic grade line or water surface profile shall be plotted with
all drainage designs. Capacity, design discharge, velocity, and velocity head shall be noted on each
segment of a drainage facility in the profile whenever one or more of these parameters changes.
4G.L.Erosion Control Plan - The developer of a subdivision or a commercial project shall submit an erosion
control plan in accordance with the requirements of Chapter 12 - Erosion Control.
M. Storm Water Pollution Prevention Plan - The deve/ooer of a subdivision or a commercial oroiect
shall submit a storm water oollution orevention olan in accordance with the requirements of the
Texas Commission on Environmental Qualitv.
~.N.Street Sian Plan - showina the location of all prooosed street name sians and traffic control
sians. The street sian olan shall include an elevation view of each street sian indicatina the tvoe
and color of each siqn. All sians shall complv with the requirements of the latest edition of the
Texas Manual on Uniform Traffic Control Devices. Refer to street sian standards. located
elsewhere in this Land Development Code (Section 14-145).
~.O.Citv Review and Approval Process - CemitnH.tieA ~1:;Jj:J~ ~!:lall ee reviewe€! BY t!:l9 City GlR€!, after all
€lemFFleRts Ra'/e BeeR Fla~@I\'e€!, &i~Re€! B} tRe gireQter ef P~Bli€l Sep{i€le~. CeR&tr~€ltieR m~st staR v:it!:liR
eRe (1) year fellevJiR~ t!:le City'~ a~~re'/al. PlaRs fer I'lF@jQQt~ '/JRiQR !:la'le Ret starte€! QeR&tr~€ltieR witRiR
tRi~ time ~erie€! m~st Be s~Bmitte€! te tRe City fer aRe....: revis'I:. All construction plans for public
improvements shall be reviewed bv city staff for compliance with this Section and with any
aoplicable Quidelines of other aaencies. City staff shall provide written comments to the
develooer and the developer shall resoond to all city comments. The Director of Public Works. or
desiQnee. shall not aporove any construction olans until all comments have been resolved and
the construction plans determined to be acceptable to the city. All aoproved construction plans
shall be sianed bv the Director of Public Works. or desianee. and no construction work shall
commence until a ore-construction meetinQ has been held and a letter of authorization to proceed
has been issued bv the Director of Public Works. or desianee. Development oroiects which have
not started within one year from the date of approval of the construction plans shall require a new
review.
Section 14.130 Street Design Criteria
14.S.A RIGHT OF '_~_(AY 'A'IDTHS
A. Riqht-of-Wav Widths - The right-of-way widths for any proposed street shall be designed for the intended
use and anticipated traffic volume at optimum development of the area served. Additional right-of-way
may be required at street intersections and to provide for left and right turn lanes at high-volume
intersections. The following table shall be used as a guide in determining right-of-way widths.
Chapter 14 - Engineering Design Standards
Page 14 - 4
Colleyville, Texas, Land Development Code
Local R2U 50 (2) 15 30 2
Cul-de-sac R2U 50 (3) 18 36 (3) 2
Minor Collector C2U 75 12 42 2 wI 9' parking or
3 wlo arkin
Major Collector (two lane) C3U 75 12 42 2 wI 9' parking or
3 wlo arkin
Major Collector (four lane) C4U 80 12 48 4 undivided
Minor Arterial M4D 95 13 52 4 divided
P4D 120 13 52 4 divided
P6D 120 12 76 6 divided
(1) Street classification refers to the functional classification shown on the Master Thoroughfare Plan.
(2) A local street having a total length in excess of one thousand two hundred (1,200) feet or serving
more than thirty (30) dwelling units may be required to provide a right-of-way width of not less than
sixty (60) feet.
(3) A cul-de-sac street exceeding 600 feet in length shall have a 56' right-of-way and 36' of pavement.
H.&.B DESIGN SPEED .A.ND M.~.XIMUM GR~.DE
B. Desiqn Speed and Maximum Grade - All streets shall be designed to conform to the following
parameters:
mm~.Q....._.__m.m..._
30 One lane or center 12'
.............................~.... .................................................. .............................,...................... ......................................................................H ...................................._.H.
Arterial 40 j 4 0.5 lOne lane in each direction
(1) The Director of Public ~ Works may approve an alternate design.
Section 14-135 Driveway Spacing and Design Standards
C. Drh'e.t:ay Spaeing and Design Standards
A. Residential Construction - Residential driveway approaches shall be constructed of six (6") inch thick
three thousand (2,000) five hundred (3.500) psi compressive strength concrete reinforced with #3 steel
bars on eighteen (18") inch centers each way, with #4 bars doweled into the existinq concrete
pavinQ. Residential driveways shall be constructed with the return curbs having a rolled face
disappearing at the sidewalk and joining the street curb.
B. Commercial and Industrial Construction - Commercial and industrial driveway approaches shall be
constructed of six (6") inch thick three thousand (2,000) five hundred (3.500) psi compressive strength
concrete reinforced with #do #4 steel bars on eighteen (18") inch centers each way, with #4 bars doweled
Chapter 14 - Engineering Design Standards
Page 14 - 5
CoJ/eyvilfe, Texas, Land Development Code
into the existinq concrete pavinq. Commercial and industrial driveways shall be constructed with the
return curbs having a rolled face disappearing at the sidewalk and joining the street curb.
C. Driveway Approach Depth - The driveway shall begin at the street curb and extend to the property line or
to a point nine and one-half (9.5') feet from the back of the curb, whichever is greater. The drive
approach shall be constructed such that the height of the drive approach at the property ROW, with a
~ tvpical nine and one-half (9.5') foot parkway, shall be two and one-half (2-1/2") inches higher than
the top of the curb. The tanqencv point of a driveway curb shall be a minimum of ten (10) feet from
a storm water inlet.
D. Driveway Approach Widths and Spacinq - The criteria contained in the following table shall be the
minimum and/or maximum standards to be applied in spacing and designing driveways on public streets.
For the purpose of this regulation, driveway width GlF-l61 s~GlsiF-lg shall be measured at the property line.
The Director of Public Ser:vises Works may modify these standards based on anticipated traffic flow and
in accordance with sound traffic engineering practices. To implement the standards contained in the
followinq table. subdivision plats for new commercial developments shall be required to provide
cross-access easements.
Driveway Spacing
(centerline)
Local 25'
..................................................... ........~. m.. ..... ...............j......
Minor Call. 25' 35'
............................... ........... .....................~ ......................M....r ........ .................. .............................. ...........................
!I\11Cij()r(:;()II, .......,.....,..,..'..'mmmmmm;m'm' ",.,,??:,; 35'
i Arterialmmmmm??,:"",}5'
~()c;CiI,., .,..,..,..,..".,..,..,..,'.".'m' ".'..'.mm. m'."..'m.'.'..,..,....,.!9..,. ,. 20'
inor CoI1.1Q'm.+ 20'
1 O'mJ?Q'.m
.. ..mm .,mm ."'."m?Q:'m}Q.'..
100'
100'
Driveway Curb Radius
Minimum Distance
from Driveway to
Intersection (0; to oi)
E. Provision for Joint Approaches - Driveway approaches shall be located entirely within the frontage of the
premises they serve except that joint, or cooperative, driveways with adjoining property holders may be
permitted by the Director of Public Sevvises Works. When a joint drive approach is proposed by a
developer, the request must be made by all interested parties and/or all property owners involved.
F. Circular Drivewav Approaches at Street Intersections - The Director of Public 5ervi"8~ Works may
approve a circular drive on a corner lot where both streets are residentially classified.
G. Anqle of Driveway Approach - The angle of the driveway approach with the curb line shall be ninety (90)
degrees.
H. Sidewalk to be Removed - Where a driveway approach is to be built, any existing sidewalk located within
the proposed driveway location shall be removed and the entire area replaced as a driveway. The drive
approach shall extend to the property line.
~.I. Driveways Crossinq Bar Ditches
Chapter 14 - Engineering Design Standards
Page 14 - 6
Colleyville, Texas, Land Development Code
a..1", The minimum culvert pipe size shall be 18" diameter. However, an engineered design that provides
for a larger culvert pipe size may be required by the developer where the Director of Public S8~i@8S
Works determines that additional drainage capacity may be required. The ends of all culvert pipes
shall be cut at a 6: 1 slope.
9. 2.Radius: Driveways shall be constructed with the return curbs joining the edge of pavement at the
street with a minimum ten-foot (10') radius.
@.LThe maximum slope from the edge of driveway to the top of the culvert pipe shall be 6: 1. The sloped
area around the end of the culvert pipe shall be sodded or hydro-mulched to resist erosion.
G.4. The minimum cross slope on the drive shall be 1/8 inch per foot. the minimum longitudinal slope
between the edge of pavement at the street and the valley over the culvert pipe shall be 1/4 inch per
foot.
Q.~Future maintenance of the drive approach and culvert pipe is the responsibility of the property owner.
f. 6.During the drive approach installation, all ditch grading upstream and downstream of the proposed
driveway culvert is the responsibility of the property owner.
a.J. General
a..1",Driveway Approaches at Pedestrian Crossings: Driveway approaches shall not be located in street
intersections or at established pedestrian crossings.
9.2. Driveway Approaches at Obstructions: Driveways shall be kept at a minimum of five (5') feet away
from obstructions such as street light posts, fire hydrants, traffic signals, etc.
G..l:,Accumulative Width of Approaches: Driveway approaches shall not occupy more than forty (40%)
percent of the frontage of a lot or tract.
Section 14-137 Fire Lane Requirements (2000 IFe Section 503)
A. Plan Approval- Plans for fire lanes shall be submitted to the Fire Marshal Division for review and
approval prior to construction. RepaintinQ of existinq markinQs does not require plan review
unless chanQes are to be made.
B. Obstructions Prohibited - Fire lanes shall be kept clear and unobstructed at all times. MarkinQ
shall be repainted as necessary to maintain readabilitv.
C. SionaQe - Where required bv the Fire Marshal. approved siQns or other approved notices shall be
provided and maintained to identify fire lanes and prohibit obstructions.
D. Where Required - Fire lanes shall be provided when any portion of the facilitv or any portion of an
exterior wall of the first stOry of the buildinQ is located more than 150 feet from fire apparatus
access as measured bv an approved route around the exterior of the buildinQ or facilitv.
E. Certain Roadways Not Considered Access - Heavily traveled public roadways are not considered
for fire apparatus access due to the danQers involved with operatinQ fire apparatus in close
proximity to movinQ traffic.
F. Access To Serve All BuildinQs - Fire lanes shall be provided to serve all buildinQs throuQh
parkino areas to service entrances. loadinq areas. trash collection areas. and other areas deemed
necessary to be available to fire and emerQencv vehicles.
G. Drivewavs Included - Fire lanes shall include driveways leadinq onto a public street.
Chapter 14 - Engineering Design Standards
Page 14 - 7
Colleyvil/e, Texas, Land Development Code
H. Fire Lane Width - Fire lanes shall have an unobstructed width of not less than 24 feet and an
unobstructed vertical clearance of not less than 14 feet.
I. Turning Radius - Fire lanes shall have a minimum inside turnina radius of thirty (30) feet and a
minimum outside turnina radius of fifty (50) feet.
J. All-weather Surface ReQuired - Fire lanes shall be desianed and maintained to support the
imposed loads of fire apparatus and shall be provided with an asphalt or concrete surface so as to
provide all-weather drivina capabilities.
K. Construction Specifications - Fire lanes shall be constructed of seven (7) inch concrete with #3
rebar on eiahteen (18) inch centers on chairs over a modified subarade as per the Geotechnical
Soils Report: or seven (7) inch asphalt over a modified subarade as per the Geotechnical Soils
Report. The construction shall be capable of supportinQ a minimum of 65.000 pounds gross
vehicle weight.
L. Maximum Dead-end Lenath - Dead end fire lanes in excess of 150 feet in lenath shall be provided
with an approved area for turnina around fire apparatus. Dead end fire lanes more than 150 feet in
lenQth but less than 700 feet in lenath shall provide one of the followinQ turn-around
confiaurations. Dead end fire lanes in excess of 700 feet in lenath shall be submitted to the Fire
Marshal for review and approval.
30'R
TYP.
24' --.
.-
~
+-24'
100' DIAMETER
CUL-DE-SAC
ACCEPTABLE ALTERNATIVE
TO 120' HAMMERHEAD
..
24'
~~R\
"70'.
.
70'
t
I~I~I
24~
.. "24'
120' HAMMERHEAD
ACCEPTABLE ALTERNATIVE
TO 120' HAMMERHEAD
M. Fire Lane Striping - Fire lanes shall be marked with a six (6) inch wide continuous briaht red
stripe on both sides. Striping shall be on the curb face where curbina is located at the edae of fire
lanes. White 4 inch hiah letterina with a one (1) inch stroke centered on red stripe shall read: NO
PARKING - FIRE LANE. This letterinQ shall be painted every (15) feet measured from the end of
one letterina aroup to the beainnina of the next aroup with a one (1) foot space between "No
Parkina" and "Fire Lane". Red paint shall not be used for any parking lot markina other than fire
lanes. Fire lane markinas are subiect to the field inspection of the Fire Marshal.
Chapter 14 - Engineering Design Standards
Page 14 - 8
Colleyville, Texas, Lmd Development Code
Section 14-140 Street Improvement Specifications
A. General - Streets shall be constructed or reconstructed using either hot-mixed asphaltic concrete
pavement sections or reinforced portland cement concrete pavement sections that meet or exceed the
minimum specifications of this Land Development Code. The developer requiring street construction shall
provide a geotechnical report, sealed by a Registered Professional Engineer licensed in the State of
Texas, containing recommendations for subgrade thickness and content. The minimum subgrade and
pavement thickness shall be in accordance with the specifications contained in this Section.
For the purpose of this Section, a collector street shall be defined as all those collector streets shown on
the Master Thoroughfare Plan and those streets internal to a subdivision which provide connection
between local residential streets and the major collector network and which are designed to
accommodate more than 500 vehicles per day.
AS. Hot-Mixed Asphaltic Concrete Pavement Sections
1. Local Streets (including cul-de-sac)
a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb
line.
b. Prime (or cure) coat.
c. Five (5") inches Type "A" or "B" hot-mixed asphaltic concrete placed in three (3) lifts. The bottom
lift shall extend to one (1 ') foot beyond the back of curb line.
d. Two (2") inches Type "0" hot-mixed asphaltic concrete placed in one (1) lift.
2. Collector Streets
a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb
line.
b. Prime (or cure) coat.
c. Six (6") inches Type "A" or "B" hot-mixed asphaltic concrete placed in three (3) lifts. The bottom
lift shall extend to one (1 ') foot beyond the back of curb line.
d. Two (2") inches Type "0" hot-mixed asphaltic concrete placed in one (1) lift.
3. Arterial Streets
a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb
line.
b. Prime (or cure) coat.
c. Eight (8") inches Type "A" or "B" hot-mixed asphaltic concrete placed in four (4) lifts. The bottom
two lifts shall extend to one (1 ') foot beyond the back of curb line.
d. Two (2") inches Type "0" hot-mixed asphaltic concrete placed in one (1) lift.
4. Stabilized Subgrade for Hot-Mixed Asphaltic Concrete Pavements
The basic design of the asphaltic pavement sections for streets and roads assumes average
subgrade conditions which in all cases shall be stabilized to not less than the thickness shown herein
with lime or cement at a minimum rate of 6% of the necessary volume or that recommended by an
approved and acceptable geotechnical report submitted to the City by iaFl Glssre€lite€l a licensed
Geotech Engineer. Classification of the subgrade for evaluating the supporting qualities shall
generally apply to the top twelve (12") inch layer of soil measured down from subgrade surface.
Where combinations of conditions indicate special problems, such as springs or seepage, drastic
material changes from point to point, etc., that reduce the existing subgrade below average,
appropriate remedies designed by a Registered Professional Engineer based upon actual onsite
observations and tests shall be included to correct the particular condition involved. In all cases, the
requirements set forth in this criteria are minimum and the City reserves the right to require further
additional testing (such as California Bearing Ratio), precautions or treatments consistent with sound
engineering practice when necessary to provide for other conditions not specifically covered by this
criteria. Compaction of stabilized subgrade shall be 95% standard proctor density.
Chapter 14 - Engineering Design Standards
Page 14 - 9
Col/eyville, Texas, Land Development Code
14.S.Q .C.Reinforced Portland Cement Concrete Pavement Sections
1. Local Streets (including cul-de-sac)~
a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line.
b. Prime (or cure) coat.
c. Six (6") inch thick portland cement concrete, reinforced with #3 reinforcing bars having a spacing
of eighteen (18") inches center to center both ways.
2. Collector Streets;.
a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line.
b. Prime (or cure) coat.
c. Seven (7") inch thick portland cement concrete, reinforced with #4 reinforcing bars having a
spacing of eighteen (18") inches center to center both ways.
3. Arlerial Streets~
a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line.
b. Prime (or cure) coat.
c. Eight (8") inch thick portland cement concrete, reinforced with #4 reinforcing bars having a
spacing of eighteen (18") inches center to center both ways.
4. Basic Requirements For All Reinforced Concrete Pavement - The basic design of reinforced concrete
pavement sections for streets and roads assumes poor subgrade conditions which shall be stabilized
with lime or cement at a minimum rate of 6% of the necessary volume or that recommended by an
approved and acceptable geotechnical report submitted to the City by 3R 6lGGreaitea a licensed
Geotech Engineer. In all cases, the requirements set forth in this criteria are minimum and the City
reserves the right to require further additional testing (such as California Searing Ratio), precautions
or treatments, when necessary, consistent with sound engineering practice to provide for other
conditions not specifically covered by this criteria.
5. Concrete for Pavement - Concrete for pavements shall be Class "A" and consist of five (5) sacks
(minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural
strength of five hundred pounds per square inch (500 PSI) and a twenty-eight (28) day compressive
strength of three thousand five hundred pounds per square inch ~ 3.500 PSI). Composition
and placement of reinforced concrete pavements shall be in accordance with the applicable
requirements of Item 364 of the Texas State Deparlment of Transporlation Standard Specifications.
Coarse aggregate shall be either number 2 or 3. Cement for the mixture shall be Type I portland
cement. All hand pours are to be six (6) sacks minimum of portland cement for each cubic yard of
concrete mix with a compressive strength of three thousand five hundred pounds per square inch
(3,500 PSI).
~.D.Curb and Gutter Specifications
All streets shall be provided with reinforced portland cement concrete curbs and gutters in accordance
with the following specifications.
1 . Curbs and gutters~
a. Curb rolls shall be six (6") inches wide and not less than six (6") inches high nor more than seven
(7") inches high,:
b. Curb and gutter bases shall not be less than twenty-four (24") inches wide and provide a
minimum gutter width of eighteen (18") inches (see detail P-4A and P-4B)~
c. Gutter depths for hot-mixed asphaltic concrete pavement shall be five (5") inches for local streets
and six (6") inches for collector and arterial streets. Gutter depths for reinforced portland cement
concrete pavement shall be the same as the pavement thickness.
Chapter 14 - Engineering Design Standards
Page 14 -10
COlleyvi/le, Texas, Land Development Code
2. Reinforcement Steel - Reinforcement shall be provided by three (3) number three (#3) steel
reinforcing bars by placing one (1) bar in the curb roll and two (2) bars in the curb and gutter base.
This reinforcement is in addition to reinforcement in portland cement concrete pavements.
3. Concrete Classification - Concrete for curbs and gutters shall be Class "A" and consist of five (5)
sacks (minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day
flexural strength of five hundred pounds per square inch (500 PSI) and a twenty-eight (28) day
compressive strength of three thousand five hundred pounds per square inch (~ 3.500 PSI).
4. Installation Procedure - Curb and gutter for hot-mixed asphaltic concrete pavements shall be placed
on the first two (2") inch lift of asphaltic paving. For reinforced portland cement concrete pavements,
the curb and gutter base shall be placed monolithically with the pavement. The curb roll shall be
placed monolithically with the pavement or added separately. Curb rolls added separately shall be
provided with number three (#3) reinforcing bar stirrups spaced twenty-four (24") inches center to
center which extend to within three (3") inches of the bottom of the pavement.
5. Driveway Cuts - All driveway entrances constructed in existing curb and gutters shall be saw-cut at
the curb return on both sides of the driveway and eighteen (18") inches into the street. After work is
completed, the street sidewalk shall be repaired and it shall be the responsibility of the party installing
the driveway.
44,.gQ.F. Street Drainaqe - The following drainage conditions shall be observed:
1. All roads shall be a crowned or roof top section so as to provide proper drainage.
2. All plats shall depict the flow of drainage with arrows sufficient to show predicted path.
3. An explanation and depiction shall be attached to show outflow and inflow availability on high flow
areas. Adjoining property where inflow originates or outflow exists must be attached to insure
compliance with drainage or excessive run-off factors.
4. No plat shall be considered for approval unless accompanied by a complete set of construction
drawings that show the drainage areas and flow calculations.
5. The contractor/developer will assume all responsibility to disperse excess run-off so as not to exceed
previous disbursements to the satisfaction of the city.
~.G.Street Construction
1. The street portion of the plat must be approved by the Planning and Zoning Commission or the
Approving Body, Fire Chief, Police Chief and Director of Public Works SePliG8s.
2. The street type code must be plainly visible on the plat and marked so that no misunderstanding can
result.
3. A performance bond must be presented to the City Secretary or duly appointed representative for an
amount equal to the contract by the contractor doing the project. A maintenance bond equal to 10%
of the contract price will be in effect for two (2) years after acceptance by the City.
4. No work shall commence without the issuance of an authorization of construction letter.
5. When Perimeter Street Escrows are required the following items shall be included in the fee
calculations.
a. Paving
b. Subgrade stabilization
c. Curb and gutter
Chapter 14 - Engineering Design Standards
Page 14 - 11
Colleyville, Texas, Land Development Code
d. Sidewalk (or pathways where applicable)
e. Excavation
f. Utility relocation (20% of paving)
g. Storm sewer improvements (20% of paving)
h. Engineering (12% of the total of items a - g)
i. Contingency (15% of the total of items a - h)
11.8.F STREETS T8 DE TRENCHED
H. Streets to be Trenched - When a G+ty public street is cut or trenched, the street wiU shall be repaired
according to this paragraph. A three (3) sack per cubic yard concrete mixture wiU shall be filled-in
beginning one (1 ') foot above the object the street was cut for and continue until one (1 ') foot from the top
of the street or reaching the plane of the sub-base compacted to 95% MeG;jifiee Standard Proctor. The
base and topping wiU shall be the minimum required for that type of street.
11.S.C Y8RFEITURE C1..'.{"JSE
I. Forfeiture Clause - Iff in the opinion of the Director of Public SePliQ9& Works'i' or his duly appointed
representative, the street project does not comply with the type code applied to the street(s), the
performance bond wiU shall be forfeited to the amount necessary to correct the substandard section if
that section(s) is not corrected by the contractor.
1. All areas in question by the City that cannot be reconciled by the contractor will be examined by an
independent testing firm, agreed upon by both parties, and its findings will prevail.
2. The cost of this testing will be borne by the incorrect party.
3. The City of colleyville reserves the right to make tests or checks at any place or any time there is a
question of ordinance compliance.
4. Any developer or contractor found to willfully and knowingly misrepresent or disregard the regulations
herein stated shall forfeit all rights and permits in the City of Colleyville, Texas, with a majority vote of
the City Council.
11.B.II TEKUJ l}EV:.RnfENT OF IImuv::.Y S"ECIFIC.'i.-'fI8NS
J. Texas Department of Transportation HiClhwav Specifications - All specifications not specifically
provided for elsewhere in this Chapter are referenced to the Texas State Department of Transportation
Standard Specifications For Construction of Highways, Streets and Bridges, 1993, AASHTO's A Policv
on Geometric DesiCln of HiClhwavs and Streets. and the Transporation Research Board's Hiqhwav
Capacity Manual.
1. Item 260 Lime Treated Subgrade - Lime used shall be Type "A" hydrated lime. The placement and
construction of the subgrade shall be done in accordance with the applicable requirements described
in Item 260 of the Texas State Department of Transportation Standard Specifications.
2. Item 270 Cement Treated Subgrade - Cement used shall be Type 1 portland cement. The placement
and construction of cement treated subgrade shall be done in accordance with the applicable
requirements described in Item 270 of the Texas State Department of Transportation Standard
Specifications. An asphaltic membrane of RC-250 asphalt shall be applied as a cure coat. An
alternate method of wet curing is also acceptable.
3. Item 310 Prime Coat - Asphalt material for prime coat shall be EA-HVMS. The placement of prime
coat shall be described in Item 310 of the Texas State Department of Transportation Standard
Specifications. Prime coat shall be placed on all lime treated subgrade at a rate of not less than 0.15
nor more than 0.25 gallons per square yard.
Chapter 14 - Engineering Design Standards
Page 14 - 12
ColleyviJ/e, Texas, Land Development Code
4. Item 340 Hot-Mixed Asphaltic Concrete Pavement - The composition and placement of hot-mixed
asphaltic concrete pavement shall be in accordance with the applicable requirements of Item 340 of
the Texas State Department of Transportation Standard Specifications. The asphalt for paving
mixture shall be AC-20 forming from 4.5 to 6.0 percent of the mixture by weight. The asphalt for use
as a tack coat under Item 340 shall be either RC-250 or EA-HVRS.
1 UtI CQl>)CRETE PIPE
K. Concrete Pipe - All concrete pipe used for drainage purpose on City streets shall be reinforced.
11.8.J l.IME TRE!.-TEQ SlJD€;R,\.QE
L. Lime Treated Subqrade - Lime treatment shall extend ten (10') feet, if feasible, beyond the completed
street when a future street is proposed to be built to assure proper conformity.
Section 14-145 Street Signs and Traffic Control Signs
A. General Reauirement - Street name siqns and traffic control sians shall be reauired for all street
intersections. Installation of siqns shall be performed bv City work crews after payment to the
City has been received from the developer for the installation costs. The Director of Public Works
shall provide the developer with a cost estimate for all siqns associated with a development. The
cost estimate shall include material and labor costs.
1. The Director of Public Works may reauire the installation of temporary street name siqns bv
the developer.
44.9A.B.Location - Street si~Rs &R;II ge &ix (9") iFl€R8& extrl;lGleGl, Ra'/s wRits lett8riR~ eR ; 911;113 9a€ik~reI;lFlGl,
138 8R~iFlser ~raGl9 refle€iterizeGl, aRGl iR€illolGle tRe ele€l{ Fllol~eer& aleFl~ witR tR9 street Fla~8. Street &i~R&
~Rallee flolrRisRsGl aRGl iFl€talleGl 9)' tRe &1;I9Gli';iGler fer all iFltsr&s€tieFls \.:itRiFl er a9101ttiFl~ tI;Je sl;Ie;i:.icj~Fl. All
signs shall be located in accordance with the Texas Manual on Uniform Traffic Control Devices.
14.Q.S SigR& C.Standards - All signs shall conform to the standards as set forth in the Texas Manual on
Uniform Traffic Control Devices. All road identification signs are to have a blue background with tf;:Jree (J)
+ooR white reflective lettering.
44.Q...G.D.lnstallation - The sign pole shall be buried to a minimum depth of two (2') feet and placed in a
twelve (12") inch diameter concrete filled posthole. The pole shall be tall enough to accommodate all
applicable signs. The bottom of tR8 ste~ all sign~ shall be located seven (7') feet above the finished
grade of the €loIfrsl;IFlGliFlg ~relolFlGl travel surface.
~.E.Approval - The developer shall submit a list of signs to be placed and a graphical representation of
the signs for review by City E:F1giFleer Director of Public Works prior to installation.
F. Custom Siqns - The Director of Public Works may approve custom-made street sians and
custom-made sian poles. provided the Director of Public Works has executed a written aareement
with a party responsible for the maintenance and replacement of such siqns or siqn poles.
Section 14-150 Sidewalk & Pathways Specifications
H.I0.A
SIQEV,'!.U( SPECIFIC}. TIQl>)S
4-.~.Permit Reauired - No person shall construct, reconstruct, alter, repair, remove or replace any sidewalk Q!
pathway on any public property within the City Limits without first obtaining a permit from the building
permit office, unless the sidewalk or pathway is included on the construction plans of an existinq
approved permit.
Chapter 14 - Engineering Design Standards
Page 14 - 13
COlIeyvilIe, Texas, Land Development Code
~.B.Maintenance Bond - No such permit shall be approved until proof of bonding coverage has been
submitted to the City and a two (2) year maintenance bond in the amount of 10% of the total cost of
construction covering the sidewalk or pathway is in full force and effect at the time of the permit approval.
Such bond shall not be valid unless persons doing the work are covered by the bond. Such bond may
cover other work done by the applicant. The Director of Public Works Citj IiR!ijiREler may waive the
maintenance bond requirement for repair to an existing sidewalk or pathway.
~.C.lnsDection Required - All work done in construction, reconstruction, alteration, repair, or removal or
replacement of sidewalks or pathways shall be inspected by the city inspector to assure compliance with
these regulations. When other public improvements are required, final acceptance of all other
improvements shall not be made until sidewalks or path wa VS are approved.
Ii.IO.R
SIBE'N.\hl( SPECIFIC:. TI91'1S
4.Q.Minimum Sidewalk or Pathway Width - All sidewalks shall be a minimum of four (4') feet in width, except
a sidewalk located within or abutting a collector street, or larger, as shown on the Master Thoroughfare
Plan, which shall not be less than five (5) feet in width. All sidewalks and pathways shall be constructed
in the area between the curb or grade line of the public street and the abutting property line unless the
pathway is situated within a dedicated pathway easement or riQht-of-wav. The edge of the sidewalk
or pathway shall generally be parallel with the curb line and be situated no more than one (1') foot from
the abutting property line. The Director of Public Works Ser/is8s may approve a plan to alter the location
of a sidewalk to preseNe a tree or for aesthetic purposes. One additional foot of width shall be added to
a sidewalk that abuts a street curb. The widths of all sidewalks and tf;aHs pathways shall be in
accordance with the following table, which are further referenced in Chapter 15 - Public Works
Construction Details.
m.Ty'p~"~.~m..
...m..Ty.PE:l...::.!3..':............
....Typ~..'.'9~.......
....Typ!:l..'g:'...... .............................................._m
T e"E"
4.0 fl.
..............................................
5.0 fl.
"'ii:'(j""ff'" .........................N.......
...................................................
10.0 fl.
m...12:ifft....-..
~.E.Construction Materials - Sidewalks shall be constructed of portland cement concrete (minimum
thickness four (4") inches). #a# Pathway system sidewalks shall be a minimum thickness of five (5")
inches. Concrete for sidewalks and pathways shall be Class "A" and consist of five (5) sacks (minimum)
of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural strength of 500
pounds per square inch (500 PSI) and twenty-eight (28) day compressive strength of 3,000 pounds per
square inch (3,000 PSI). Reinforcement shall be in accordance with the construction detail contained in
Chapter 15 - Public Works Construction Details. In such cases, reinforcements shall be #3 steel
deformed reinforcing bars on eighteen (18") centers.
a..F. Architectural Barriers Act - All sidewalk/street intersections shall be constructed so as to provide a ramp
- that complies with the Architectural Barriers Act. Barrier free ramps shall be provided for access to the
street. The following specifications shall apply:
eLRamp to be minimum four (4') feet in width.
9.2. Ramp to be constructed with Class "A" concrete.
G.3. Ramp concrete thickness shall be the same as the street (six (6") inch normal residential).
€1.4. #3 bars shall be used for reinforcement (twenty-four (24") inch on centers).
8.S.curb return shall match existing curb height of the street and taper to the connecting walk with a 1-
foot radius.
f.6. Street shall be blocked out (max. twelve (12") inches) and dowels installed.
r;;z. Saw joints shall be made one and a half (1 1/2") inch minimum depth and sealed with silicone joint
sealant material.
A.B. Subgrade shall be prepared to a minimum depth of six (6") inches.
+'9. At no time shall the walk running parallel to the street be altered.
j.10Surface of walk shall be coarse and ribbed to provide extra traction (see detail P-8).
Chapter 14 - Engineering Design Standards
Page 14 - 14
Colfeyville, Texas, Land Development Code
Where the above specifications do not apply or have jurisdiction, refer to the specifications from the
American Disabilities Act.
Section 14~155 Street Lighting
11.11.A
CENER.U. REBlHREl\1EI'IT
4-. A. General Reauirement - Street lights shall be installed at all intersections, at the end of all cul-de-sac
streets, and at additional locations in accordance with the following table:
At intervals of not
more than three
hundred 300 feet
Wood or metal
1 00 watt
high pressure
sodium
30 feet
~B.Spacina - The number of required street lights shall be equal to the total linear footage between street
intersections divided by the required spacing. Fractions of street lights shall be rounded to the next whole
number.
3.C.lntervals - Street lights shall be placed at approximately equal intervals between intersections and shall
be subject to the approval of the Director of Public Works €lily eR~iREl8r.
4.D.Desian - Cobra head lamps shall be provided on standard street lighting fixtures, except that other lamp
types may be permitted where custom lighting is approved by the Director of Public Works ~
8R~iRe9r.
11.11.B. CHSTQU 1.1GIITll'lfJ
4-. E. Custom Liahtina - The subdivider may elect to provide custom lighting lieu of the required standard
street lighting, subject to the approval of the city engineer.
~F. Custom Liahtina Maintenance - If a subdivider elects to provide and install custom lighting, a
homeowner's association (or some other such private entity) shall be created which will be perpetually
liable for all costs associated with the maintenance of the lighting fixtures. Where the city is not liable for
the costs of electrical energy from the custom lighting as provided in this subsection, the homeowner's
association shall also be liable for the electrical energy costs of the custom lighting.
Section 14-160 Water System Improvements
11.12.1.
CE!\IER.\1>
A. General - This section pertains to general design requirements for water distribution system construction
in the City of COlleyville. All water lines shall be sized and designed in accordance with the City of
Colleyville Water Distribution System Master Plan or as determined by the Director of Public Works
SePiliG8s. In the absence of specific standards, all water supply, distribution, pumping, and storage
improvements shall be designed in accordance with the most current standards of the American Water
Works Association or the Standard Specifications for Public Works Construction of the North Central
Texas Council of Governments or criteria adopted by the Texas Administrative Code, Chapter 290,
"Water Hygiene".
44.42.8. Line Sizes & Locations
1. Standard water line sizes are, 8 inch, 10 inch, 12 inch, 16 inch, 20 inch, and 24 inch diameter. Other
sizes may be approved by the Director of Public Works SElP/i€l8S.
Chapter 14 - Engineering Design Standards
Page 14 - 15
Colfeyville, Texas, Land Development Code
2. All water lines shall be looped. Dead end lines shall not exceed 600 feet, unless approved by the
Director of Public Works Servi€les. No services shall be allowed on a dead end line.
3. Water lines shall be located within the parkway. Along State Highways, water lines are required on
both sides of the roadway. New water lines crossing existing streets shall be placed by boring. A
casing shall be required under major and minor collector roadways, arterial roadways and Highway
26 (Colleyville Blvd.). Open cut excavation will not be allowed to cross existing streets, unless
approved by the Director of Public Works Servi€lEls.
4. Easements for water line construction shall meet the following requirements:
a. The easement width shall be a minimum of 15 feet.
b. In areas where multiple easements exist the easement may need to be wider as specified by the
City.
5. All piping with mechanical couplings, push-on, or similar joints subject to internal pressure shall be
designed with blocking, anchors, and restraining harnesses to preclude separation of joints.
6. Water lines for multi-family, commercial and industrial fire protection lines shall be dedicated to the
public, unless the system is isolated from the public system by a detector check. All water lines shall
be a minimum of eight (8") inches in diameter and looped when possible. Dead end lines shall not
exceed 50 feet on multi-family, commercial, or industrial sites. All public water lines located on
private property shall be centered in a 15-foot minimum easement. Larger easements may be
required by the Director of Public Works SerVi€l9S to provide adequate space for maintenance.
Water lines shall not be located under paved surfaces where possible.
~C. Line and FittinQ Materials- All water lines and fittings shall be new materials and comply with the
following:
1. Water Lines - All water lines shall be Polyvinyl Chloride (PVC) material and be designed,
manufactured, and tested in accordance with the applicable requirements of AWVl/A c-900 (eight (8")
inch through twelve (12") inch water pipe) AWVl/A c-905 (sixteen (16") inches and larger water pipe),
and AWVl/A M-23.
2. Other Pipe Material - All other materials must be submitted for approval by the Director of Public
Works Sewi€lEls. Ductile Iron pipe is an acceptable substitution.
a. All PVC water pipe shall be blue in color.
b. Eight (8") inch through twelve (12") inch water pipe shall be pressure class 150, DR 18. Pressure
class 200, DR 14 pipe may be required by the Director of Public Works Sewi€les in areas of high
distribution system pressure, under roadways or other unusual circumstances.
3. Fittings - FittiFl~S All fittinQs shall be ductile iron in accordance with AWVl/A C11 0 or AWVl/A C153.
a. Fittings: ANSI/AWVl/A c111/A21.11, except gaskets shall be neoprene or other synthetic rubber
and factory installed. Natural rubber will not be acceptable.
b. All buried metal shall be wrapped in polyethylene Tube Wrap: ANSI/AWVl/A C1 05/A21.5.
c. All waterline pipe and fittings shall be new materials and produced in the USA
11.11.>>. Il"IST.\I;.L\TI8~!
D. Installation - All installations shall conform to the latest NcTCOG, TCEQ HJRCC, and AWVl/A
Specifications, as amended by these standards.
1. All eight (8") inch and ten (10") inch pipe shall be installed with a minimum of forty-eight (48") inches
of cover over top of pipe, and pipe twelve (12") inches and larger shall be installed with a minimum of
sixty (60") inches of cover over top of pipe.
2. The amount of trench excavation shall not exceed two hundred (200') feet from the end of the pipe
Chapter 14 - Engineering Design Standards
Page 14 -16
Colleyville, Texas, Land Development Code
laying operations, and no more than three hundred (300') feet of total open trench will be allowed. At
the end of each work day, all trench excavation shall be backfilled and compacted to the end of the
pipe laying operation. Barricades and lights will be required around any open trench or equipment
and cover plates are required in traffic areas.
3. All connections to existing water mains shall be made under pressure unless dry connections will not
cause any loss of service. Under special conditions connections that cause an interruption of service
may be performed with approval of the Director of Public Works Servi@9s.
4. Coated tracer tape or wire shall be installed in the embedment material twelve (12") inches above the
PVC pipe with the tracer wire terminating in in-line gate valve boxes accessible by City Staff.
5. Density tests shall be taken at a minimum of every one hundred (100') feet for every lift. A maximum
thickness of twelve (12") inches per loose lift is required for all trench backfill. The compaction of
backfill shall meet or exceed 95% Standard Proctor density. A geotechnical report should be
submitted for all trenches. The density reports shall be submitted daily to the City Inspector. The City
has the right to require additional tests if they are deemed necessary.
6. All density reports and bacteria test reports shall be completed, delivered to the Director of Public
Works City I!!Fl!!liFleer and Inspector, and approved before paving is allowed to begin.
7. PVC water pipe and appurtenances shall be installed as specified in AWNA M-23 and in accordance
with the pipe manufacturer's recommendations.
8. Fittings shall be installed in accordance with AWNA C-600.
a. All mechanical joint bends, tees, and reducers which require blocking shall be additionally
restrained with EBAA megalug retainer gland or approved equal.
b. All fittings must be polyethylene wrapped.
11.11.E
FIRE IIYDn!.l'ITS
E. Fire Hydrants
1. Hydrant Location and Spacing - Fire hydrants shall be provided alona fire apparatus access
roads and adiacent public roads. iFl @sfflffler@ial aFl€l iFl€lIol~trial areas &Rall seFlerally Iae Is@ate€l at
street iFlterSeGtieFls aFl€l &I'laee€l &8 a& t8 I'lrsvi€le fire Ry€lraFlt Gsverase \.Jitl;! a ff1a)(iffllolffl ra€lilol& sf
tl;!ree I;!IoIR€lre€l (Jgg') feet aR€l a ff1aXiffllolffl I;!S~9 lay sf five I;!IoIR€lre€l (599') feet. Fir;e Ry€lraRt& iR a
resi€leRtial area sRall seFlerally Iae Is@ats€l at ~tr99t iFlter~e@tisFlS aR€l Sl'la@e€l &S as ts I'lre\'i€l9 fir;e
Ry€lraFlt @evera!!l9 witR a ff1aXiffllolffl ra€lilols sf five RIoIFl€lrs€l (599') feet aFl€l a ff1axiffllolffl Rese lay sf six
RIoIFl€lre€l (099') feet. (0-00-1261 12/19/00)
a. The minimum number of fire hydrants available to a buildinQ shall not be less than that
listed in Appendix B of the 2000 International Fire Code. as amended.
b. The number of fire hydrants available to a complex or subdivision shall not be less than
that determined by the spacina reQuirements in the followina table. when applied to fire
apparatus access roads and perimeter public streets from which fire operations could be
conducted.
Chapter 14 - Engineering Design Standards
Page 14 -17
Colleyville, Texas, Land Development Code
1 750 0 1
2000- 2
2500 3
3000 3
3500- 4
mm..........4.500 - 5.000mmm ......mmmm. mm2
mmmm 5.500 ........ ..mmm ....... ..m~ m ..m...... ..m.... . ... .,
.mm 6.000....... ..... ................ .....~.......
mm.. 6.500 - 7.000.mmmmmmmmmmmZm m.. ........ ....
7 500 or more 8 or more
500
450
450
400
...m..!JM
... ... . . . . m..............!J.QQ
. . . . . .mm!J.QQ
......................Wl
.....................Wl
200
m .....mmm~
.....mll2m
m '.mm ..Zl2
.....mmm.. mmmZl2
........................................m.llimm..........m...mm...m.
............... ..mmmm........mm..Wl
............ ..mm ......mm...............Wl
.. m.. m.... . mmm ..mmm12!lm ....
.......... ........................... ..mm ..m12!l
120
2. Materials - Fire hydrants shall be manufactured in accordance with AWWA c-502, Dry-Barrel Fire
Hydrants. Hydrants shall be manufactured such that all maintenance and adjustments can be
performed without excavation and such that hydrants may be faced in any direction in relation to
base.
6.3. Installation depth - The standard fire hydrant bury length from ground to bottom of the connecting
pipe shall be three (3') feet six (6') inches. The hydrant shall be of a design that will permit extensions
without disturbing the bottom section of the hydrant.
G4. Gate valve - A gate valve shall be installed with each fire hydrant.
~5. Manufacturers - Approved fire hydrants manufacturers are as follows:
a. Mueller Centerion A-423
b. Watrous Pacer - 100
c. Clow
3.6. Locations - Fire hydrants are to be located a minimum of three (3') feet and a maximum of six (6')
feet behind the back of curb.
l~.U.F
~7L'''l. "ES
F. Valves - Valves of approved design shall be installed at the intersections of all water mains so as to
provide for proper maintenance and operation of the system and to provide a means of shutting off
the supply to portions of the system for repairs.
1. Valve Spacing - Valves shall be spaced such that only one fire hydrant is out of service at any
one time. Three (3) valves shall be used on a four-way water line intersection and a minimum of
two (2) valves shall be used on a three-way intersection.
2. Valve Types - Resilient seated gate valves shall be used for six (6") inch through twelve (12")
inch water lines. Butterfly valves shall be allowed for twelve (12") inches and larger water lines
when approved by the Director of Public Works SeP-liees.
3. Valve Materials
a. Resilient Seated Gate Valves
(1) Resilient seated gate valves six (6") inches through sixteen (16") inches shall meet or
exceed the latest revisions of AWWA C509 and shall meet or exceed the requirements of
these standards.
(2) Resilient seated gate valves for buried service shall be furnished with a square two (2")
inch operating nut. The valve box shall be Tyler Pipe 6850 series or approved equal.
Chapter 14 - Engineering Design Standards
Page 14 -18
Colleyville, Texas, Lmd Development Code
The valve box lid shall be painted safety blue. The paint shall be Glidden or approved
equal.
(3) All valves must open left and close right.
b. Butterfly Valves - Butterfly valves shall meet or exceed the latest revision of AWWA Standard
C504 for Class 150B butterfly valves and shall meet or exceed the requirements of this
specification. All valve components shall conform to Underwriters Laboratories classification
in accordance with ANSI/NSF Standard 61.
4. Valve Installation
a. Valves shall be furnished with extensions, such that the working nut is a maximum of thirty-
six (36") inches below grade.
b. Adjustable valve boxes shall be furnished and set on each valve in accordance with these
standards. Valves that are deeper than forty-eight (48") inches, AWWA c900 PVC pipe shall
be used for stacks, as long as the adjustable valve box is used at the top.
c. After the final clean-up and alignment has been complete, the contractor shall cast in place a
concrete block, twenty-four (24") inches by twenty-four (24") inches around all valve box tops
at the finish grade. See detail W-3.
d. Valves located within a right-of-way shall be indicated on the face of the curb, or where curbs
do not exist, on a conspicuous location adjacent to the valve location. Markings are to be the
stamping of a four (4") inch high letter "v" with a three-eighths (3/8") inch stroke with the point
of the "V' pointing towards the valve location.
e. Valve markers shall be provided in rural areas.
5. Valve Manufacturers
a. Approved manufacturers of six (6") inch through twelve (12") inch resilient seated gate valves
are as follows:
(1) Mueller, Claw and Waterous
b. Approved manufacturers of sixteen (16") inches resilient seated gate valves are as follows:
(1) Mueller
c. Approved manufacturers of sixteen (16") inch and larger butterfly valves are as follows:
(1) Mueller and Clow
11.1J.C
AIR REhKHJE :.1"ID Fhl,'Smrl(;j Y+.hYES
G. Air Release and Flushina Valves - Adequate air relief, and flushing valves shall be provided for
flushing, disinfecting, daily operation requirements, and repairs when required by the Director of
Public Works Ssp:is9s. Air release valves shall be required on twelve (12") inches and larger water
lines. Water lines shall be designed so that each section of the water line can be flushed at its lowest
and highest points.
~1.AII dead end lines shall have a fire hydrant installed for flushing purposes. If installation of a fire
hydrant is not possible, a flushing valve is required.
a..2.A fire hydrant shall be required at high points on water lines smaller than twelve (12") inches for
air relief and flushing.
4.3. Materials - Air release valves and air/vacuum valves shall meet or exceed the latest revision of
Chapter 14 - Engineering Design Standards
Page 14 -19
Colleyville, Texas, Land Development Code
AWWA C512.
11.12.11 T:.PPU'I€J ShEE\'E
H. TaDlJina Sleeves - A tapping sleeve and valve shall be used when connecting a new water line to an
existing line. A resilient seated gate valve shall be flanged to the tapping sleeve. The tapping sleeve
shall be a Smith-Blair Spec. 664-665 stainless steel tapping sleeve, or approved equal.
11.12.1
'lV.HER SER'/ICE
I. Water Services
1. Meter Box Locations - The water meter box shall be placed a minimum of two (2') feet behind the
back of curb unless sidewalks are adjacent to the curb, then they are to be set seven (7') feet behind
the back of curb, and the water service shall be a minimum of twelve (12") inches deep, covered with
a meter box in place at grade. If no curb is present, the water service shall be located at the property
line, a minimum of twelve (12") inches deep, covered with a meter box in place at grade. Along
roadways without a curb the water service line shall be constructed at a minimum of twelve (12")
inches below the ditch flow line. All water services crossing beneath streets may be encased in four
(4") inches diameter PVC casing.
2. Meter Size - Meter and service sizes will be determined by the developer prior to requesting service
from Colleyville. The minimum water service size between the water main and the meter shall be one
(1") inch. Water services on undeveloped lots shall be located at the property line and shall be a
minimum of one (1") inch in diameter.
3. Materials
a. Service Saddle - Service saddle shall be double strap bronze with brass body or nylon I epoxy
coated stainless steel double bolt wide straps. Minimum size tap shall be 1 inch diameter.
(1) Approved manufacturers for bronze saddles are Ford, Mueller, Jones or Smith-Blair.
(2) Approved manufacturers for nylon stainless steel saddles are Ford, Mueller, JcM or Romac.
b. Service Line - Service lines shall be one (1") inch minimum diameter, Type K copper as specified
in ASTM B88.
c. Corporation Stop - Corporation stop shall be ball type with a diameter equal to the pipe size with
compression outlet fitting, designed for a minimum working pressure of two hundred pounds per
square inch (200 psi) and threaded counter clockwise. Approved manufacturers are Ford or
Mueller.
d. Angle Stop - Angle stop shall be set with compression inlet fitting and locking wings. Approved
manufacturers are Ford, Mueller or Smith Blair.
e. Meter Boxes - Meter box for one (1") inch meters are to be East Jordan Iron Works brand and
are to be #37-S Plastic Box with Cast Iron Lid. Meter box for one and one-half (1 Yz") inch and
two (2") inch meters shall be East Jordan Iron Works brand and are to be a 15x27 plastic box with
2 65T dual lids.
4. Installation
a. All water service! shall be installed in accordance with these standards.
b. Each individual service location shall be saw cut into the face of the curb with a four (4") inch high
'W" painted blue by the Contractor. If no curb exist a similar mark should be placed in the
pavement near the edge of the roadway.
5. Acceptable Manufacturers for Corporation Stops. Curb Stops. and Service Saddles
Chapter 14 - Engineering Design Standards
Page 14 - 20
Colleyville, Texas, Land Development Code
a. Ford
b. Mueller
c. Smith-Blair
11.1J.J
FU:fSIIIN€J 'lz, '1.1:, '.'ES
J. FlushinCl Valves
1. Materials
a.L..Corporation stop shall be two (2") inch ball type with compression outlet fitting, designed for a
minimum working pressure of two hundred pounds per square inch (200").
9.2. Two (2") inch curb stop shall be ball type with compression inlet fitting with tee head shut off.
G.3. Pipe shall be two (2") inches diameter, Type K copper as specified in ASTM B88.
9.4. All flushing valves shall be installed within a twenty-four (24") inch round metal meter box.
11.l2.K W".rER 1.1l'JE R9RE
1. Casir:H~s K. Water Line Borings - Casings shall be required under collectors and thoroughfares,
highway crossings, and railroad crossings. Casings may also be required where deemed necessary
by the Director of Public Works ServiGes. Minimum casing thickness shall be a quarter (1/4") inch.
The construction bore pit shall be located a minimum distance of four (4') feet behind the back of curb
or edge of pavement where no curb is present.
2-.1. Casinq Desiqn - The design engineer shall design the water line pipe casing for the following
loading conditions and applicable combinations thereof:
a. Cooper's E-80 Railway loading or AASHTO HS20 loading as applicable.
b. Earth loading with the height of fill above the casing as shown on the plans.
c. Loads applied during jacking, including axial load from jacking.
d. All other applicable loading conditions, including loads applied during transportation and
handling.
...2. Casing Materials
a. Steel Casing Pipe - Steel casing pipe shall be new (or used if approved by the Director of
Public Works ServiG8s) and suitable for the purpose intended and shall have a minimum
yield strength of 35,000 psi. Casing shall meet ASTM A-36, ASTM A-570, ASTM A-135,
ASTM A-139, or approved equal. Pipe shall be coated with coal tar epoxy (15 mils min.) in
accordance with AWWA C-210. Pipe joints shall be welded in accordance with AWWA C-
206. After pipe is welded, coating shall be repaired.
b. Cement Mortar - Cement mortar shall consist of one (1) part cement to two (2) parts clean
sand with sufficient water to make a thick, workable mix.
c. Pressure Grout Mix - Grout shall be comprised of one (1) cubic foot of cement and three and
a half (3.5) cubic feet of clean fine sand with sufficient water added to provide a free flowing
thick slurry. If desired to maintain solids in the mixture in suspension, one cubic foot of
commercial grade bentonite may be added to each twelve (12) to fifteen (15) cubic feet of the
slurry.
d. Casing Insulators (Spacers) - Use casing insulators for any type of carrier pipe. Insulators
shall be high density polyethylene. Insulators shall fit snug over the carrier pipe and position
the carrier pipe approximately in the center of the casing pipe to provide adequate clearance
between the carrier pipe bell and the casing pipe. Insulators shall be manufactured by
"Recon" and be Racci Type or approved equal.
Chapter 14 - Engineering Design Standards
Page 14 - 21
Colleyville, Texas, Land Development Code
4.3. CasinCllnstallation
a. Excavation and Backfill of Access Pits
(1) Do not allow excavation over the limits of the bore or tunnel as specified. Trench walls of
access pits adjacent to the bore or tunnel face shall be truly vertical. Shore the trench
walls as necessary to protect workmen, the public, structures, roadways, and other
improvements.
(2) Excavations within the right-of-way and not under surfacing shall be backfilled and
consolidated by mechanical methods as specified in these standards for compaction of
trenches under roadways. Surplus material shall be removed from the right-of-way and
the excavation finished to original grades. Backfill pits immediately after the installation
of the carrier pipe is completed. If carrier pipe is not installed immediately after casing
pipe installation, the City may require the access pits be temporarily backfilled until
installation of carrier pipe.
(3) Where seeding or sodding is disturbed by excavation or backfilling operations, such
areas shall be restored to the existing or better conditions.
Section 14-165 Wastewater System Improvements
1 ~ ,1 J.j'..A.General - This section pertains to general design requirements for wastewater collection system
construction in the City of Colleyville. All sewer lines shall be sized and designed in accordance with the
City of Colleyville Waste Water System Master Plan or as determined by the Director of Public Works
SePJiG8s. In the absence of or in conflict with a specific standard contained in this Chapter, all collection,
treatment, and disposal systems shall be designed in accordance with the most current criteria adopted
by the Texas Administrative Code, Chapter 317, "Design Criteria for Sewerage Systems", NCTCOG,
TCEQ HJRCC and ASTM.
H.IJ.B
SE',YER LUIE SIZES .HID DESIQrl
B. Sewer Line Sizes and Deskm
1. Standard sewer line sizes are six (6") inches, eight (8") inches, twelve (12") inches, fifteen (15")
inches, and eighteen (18") inches in diameter. Other sizes may be approved by the Director of Public
Works SePJiGe~.
2. Sewer lines shall be constructed at a minimum depth of four (4') feet and be located within the
parkway or an approved utility easement. A sewer line is required to be constructed on both sides of
a State Highway.
3. Easements for sewer line construction shall meet the following requirements:
a. The easement width shall be a minimum of fifteen (15') feet. Greater easement width may be
required for deep lines.
b. If the sewer line is less than twelve (12') feet deep, the outside diameter of the sewer line shall be
located a minimum distance of six (6') feet from the edge of the easement, and if other utilities are
located in the same easement, the outside diameter of the sewer line shall be located a minimum
distance of three (3') feet from the outside diameter of the other utilities.
c. If the sewer line is greater than twelve (12') feet deep, the outside diameter of the sewer line shall
be located a minimum distance of nine (9') feet from the edge of the easement, and if other
utilities are located in the same easement, the outside diameter of the sewer line shall be located
a minimum distance of six (6') feet from the outside diameter of the other utilities.
d. Proper separation of utilities must be maintained per TCEQ HJRCC regulations.
Chapter 14 - Engineering Design Standards
Page 14 - 22
Cofleyville, Texas, Land Development Code
4. All sewers shall be designed with consideration for serving the full drainage area subject to collection
by the sewer in question; the drainage area may be modified with the concurrence of the Director of
Public Works Sewis8& because of the projected rate of development or the financial feasibility of the
proposed extension.
5. Sewers should be designed with straight alignment whenever possible. When horizontal curvatures
must be used, radial pipe must be used in accordance with the pipe manufacturer's
recommendations. No joint deflection is allowed without the approval of the Director of Public Works
SSWiS8&.
6. All sewers shall be designed with hydraulic slopes sufficient to give mean velocities, when flowing full
or half full, of no less than two (2') feet per second.
7. When a one hundred fifty pounds per square inch (150 psi) rated sewer line is required due to its
proximity to a water line, the one hundred fifty pounds per square inch (150 psi) rated pipe shall
terminate at a manhole on each end. The pipe shall be extended to the interior wall of the manhole.
No external boot connection will be allowed.
11.U.C
SE'\'.'ER LIl'lE M:.TERL'.b~
C. Sewer Line Materials - All sewer lines and fittings shall be new materials and comply with the following:
1. All sanitary sewer pipes shall be Polyvinyl Chloride (PVC) pipe type SDR-35 for sewer lines
constructed less than fifteen (15') feet deep. SDR-26 shall be provided where sewer lines exceed
fifteen (15') feet. PVC pipe will not be allowed for depths greater than twenty four (24') feet unless
approved by Director of Public Works Servisss.
2. All PVC sanitary sewer pipe shall be green in color. Developer to provide a manufacturers statement
for pipe color other than green.
3. PVC sewer pipe and fittings shall conform to the current ASTM Designation D 3034 for four (4")
inches through fifteen (15") inches and ASTM Designation F 679 for greater than fifteen (15") inches.
11.lJ.ll
SE'.'.'ER LII'IE II"I~Fr.\bb:<,'fI91'1
D. Sewer Line Installations
1. General
a. All installations shall conform to ASTM Designation D2321, and the latest NCTCOG
Specifications as amended by these standards.
b. Sewer lines shall not be installed within nine (9') feet horizontally of any water main or fire
hydrant. Where this is not possible, separation shall be in accordance with TCEQ nlRCC
standards.
c. Construction shall begin at the downstream end of project and continue upstream with the bell
facing upstream. No upstream piping shall be installed before downstream piping unless
approved by the Director of Public Works Serviss€:.
2. Excavation and Backfill
a. Filter fabric shall be installed separating the backfill material from the rock embedment no more
than twelve (12") inches above the top of the pipe.
b. The amount of trench excavation shall not exceed two hundred (200') feet from the end of the
pipe laying operations, and no more than three hundred (300') feet of total open trench will be
allowed. At the end of each workday, all trench excavation shall be backfilled to the end of the
pipe laying operation. Barricades and lights will be required around any open trench left
overnight.
Chapter 14 - Engineering Design Standards
Page 14 - 23
Colfeyville, Texas, Land Development Code
c. Density tests shall be taken everyone hundred (100') feet for every lift. A maximum
thickness of twelve (12") inches per loose lift is required for all trench backfill. A geotechnical
report should be submitted for all trenches. The compaction of backfill shall meet or exceed
95% Standard Proctor density. The density reports shall be submitted daily to the City
Inspector. The City has the right to require additional tests if they are deemed necessary.
d. A City inspector will be on site at all times when testing is being performed. The City Inspector
shall be present during the placement of trench backfill lifts.
e. All density reports shall be completed, delivered to the Director of Public Works City's 1iF1!JiR99r
and Inspector, and approved before paving is allowed to begin.
3. Inspection and Testing
All sanitary sewer lines shall be inspected using standard television inspection methods prior to
acceptance by the City. The developer is responsible for television testing.
a. The Contractor is responsible for cleaning the sewer pipe. If the inspection shows debris or
evidence that the line has not been properly cleaned, the review will cease and the tape will be
returned to the Contractor.
b. A City representative will be present during the television inspection and all other testing
procedures, unless otherwise authorized in writing.
c. The televised inspection shall commence only after the line has passed both air and mandrel test.
d. The sanitary sewer system must pass all air, mandrel and television tests prior to paving.
e. The air and mandrel test must meet the required specifications set forth by the NCTCOG and
TCEQ nIRCC.
f. All sanitary sewer mains must be flushed clean with water just prior to televised inspection. All
debris must be captured and prevented from blocking the system. Water is to be provided at the
Contractor's expense. A City representative is to be present during the flushing of the main.
g. All television equipment used shall have a minimum of two hundred twenty (220) lines of
horizontal resolution. The picture shall be in color.
h. All video information on tape must have good picture quality.
i. As a title heading on the tape and during the televising, the operator must not! the following:
(1) project name and Contractor name.
(2) name of the company and the operator performing the video inspection.
(3) line size and material, joint type and length.
(4) line segment to be televised including beginning and ending station numbers.
(5) page of plans used and year plans were stamped.
(6) date and time of inspection.
(7) A footage counter must be displayed on the tape during the filming.
(8) Show the above title block before and after each line segment. Show the title block at one
hundred (100') foot intervals while filming the line segment.
(9) All defects should be shown on film for a minimum of ten (10) seconds before proceeding
with the televising.
j. The Contractor shall supply a log sheet used in conjunction with the video tape for written
documentation. All written information gathered must be legible and clearly understandable.
(1) Note the project name, Contractor name and contract number.
(2) Note the name of the company and the operator performing the video inspection.
(3) Note pipe size and material, joint type and length between joints.
(4) Note the VCR tape footage counter, start to end.
(5) Note line segment to be televised, station numbers from and station numbers to length of line
segment as indicated on plans.
(6) Note page of plans used and year plans were stamped.
(7) Note date and time of inspection.
(8) Indicate by sketch the line segment to be televised in relation to surrounding road
intersections and street addresses. Identify manhole station numbers. Show direction of flow
with arrows and direction the camera is going. Indicate direction of north on the sketch.
Chapter 14 - Engineering Design Standards
Page 14 - 24
Colleyville, Texas, Lmd Development Code
(9) Note the water depth at the beginning, every fifty (50') foot station, every change in grade,
and at the end of the line segment.
(1 O)ldentify the clock location, direction, size and type of laterals entering main. Indicate laterals
as saddles, punched, or glued fittings.
(11) Indicate final footage televised at end of the log sheet.
k. One tape per visual televised inspection project shall be furnished to the Project Inspector.
I. Tapes must be VHS format, one (1") inch wide T-120, high quality tape. Tapes are to be recorded
on SP (2 hours) play.
m. All tapes and run sheets shall be submitted to the City. All tapes and log sheets shall become the
property of the City.
4. Criteria for Repair
The Contractor shall make repairs if the inspection reveals any deficiency in the sewer line. If repairs
are required, another television inspection shall be made after the repairs are complete on a new tape
from manhole to manhole at the Contractor's expense. Any water discovered with a depth of more
than one-quarter (1/4") inch will require removal and replacement of the portion of the line not within
specification. Repairs shall be made to the satisfaction of the Director of Public Works Sep/iees.
11.U.C
M:"J'!II8bE~
E. Manholes
1. Manholes shall be located at all intersections of sewer lines and at intermediate spacing along the
line. Generally the maximum spacing should not exceed five hundred (500') feet. Manholes should
be located at all changes in grade and at the ends of all sewer lines that will be extended.
2. A manhole is required at the junction of sewer lines with different inside pipe diameters.
3. A drop of at least one tenth of a foot (0.1 ') is required through the manhole when a change in flow
direction occurs.
4. A drop manhole is required when the flow line in is two (2') feet or more greater than the flow line out.
5. Minimum manhole inside diameter is four (4') feet.
6. Drop-connection manholes shall have a minimum inside diameter of four (4') feet, with an exterior
drop.
7. Minimum cast-in-place manholes must be installed to the North Central Texas COG standards.
8. Minimum pre-cast wall thickness is five (5") inches.
9. A manhole is required where a sanitary sewer line enters and exits private property.
10. All manholes shall be concrete.
11. IFlstallati@F1 a.
Sanitary sewer manhole sizes shall be in accordance with the following table:
Chapter 14 - Engineering Design Standards
Page 14 - 25
Colleyville, Texas, Land Development Code
Under 12"
...................~....................
Under 12"
...........................................................
12" to 18"
<12'
................................................
> 12' - 20'
<12'
>12' - 20'
4'
....................................................................
5'
5'
6'
3
...........................................................................................
3
3
4
Note: If the proposed design requires the sewer line to be placed at depths greater than
shown above, the design will require approval by the Director of Public Works esp-iess.
9=. 12. Cast-in-place Manholes
t4t!!:. The manhole foundation shall be poured on undisturbed soil and shall have a minimum
thickness of eight (8") inches.
~~ The inlet and outlet pipes shall be poured into the foundation of the manhole. When straight
through flow occurs, the pipe shall be laid continuously through the manhole.
f3t....f:. The invert shall be shaped and smoothed so that no projections will exist and the invert shall
be self cleaning.
f4t d. When a cast-in-place manhole is used to connect to an existing sewer line the manhole should
be poured, tested and approved before the top of the existing line is cut out.
fit !:. Concrete work shall conform to all requirements of ACI 301, Standard Specification for
Structural Concrete, published by the American Concrete Institute, except as modified herein.
~...t. Detailing of concrete reinforcement and accessories shall be in accordance with ACI
Publication 315.
fA 9.:. Portland cement shall be Type II, low-alkali and conform to ASTM Designation C-150.
~) h. The manhole shall not be backfilled within twelve (12) hours after the concrete placement.
Backfill shall be compacted and reports submitted to the City.
f'#) !.:. The face of curb shall be stamped with a three (3") inch "MH" to mark the location of all
manholes. The location of the stamp shall be a line that intersects the center of the manhole
cover and the curb perpendicular to the centerline of the street. For manholes located in
intersections, the curb shall be stamped at the closest location to the manhole. If no curb exist a
similar mark should be placed in the pavement near the edge of the roadway.
6.13. Precast Manhole!
t4t!!:. Precast manholes shall be constructed in accordance to ASTM Designation C-478.
~b. Manhole base shall have a spread footing and be placed on a minimum of twelve (12) inches
of crushed rock.
~.14. Manufacturers - Approved precast manhole manufacturers are as follows:
a. Hydro-conduit
b. Gifford Hill American
l~.U.Q
M.\nIISl,E FR.\I'lIE .\1'18 CSYER
F. Manhole Frames and Covers
1. Cover
a. Materials - All manhole covers shall conform to the Standard Specifications for Domestic Grey
Iron Castings, ASTM A-48, Class 30 B.
b. Installation
(1) All manhole covers shall be twenty four (24") inches in diameter.
Chapter 14 - Engineering Design Standards
Page 14 - 26
Col/eyville, Texas, Land Development Code
(2) All manhole covers shall have two (2) integrally cast pick bars.
c. Manufacturers (Traffic rated where necessary)
(1) Bass and Hays
(2) Vulcan
2. Frames
a. Materials - All manhole frames shall conform to the Standard Specifications for Grey Iron
Castings, ASTM A-48, Class 30 B.
b. Installation - All manhole frames shall provide a twenty four (24") inch by one quarter (1/4") inch
opening to assure proper fit of the manhole cover.
c. Manufacturers
(1) Bass and Hays
(2) Vulcan
d. Manholes located within the floodplain are to be sealed cover and frame.
3. Extension Ring~
a. Materials - All precast reinforced concrete extension rings shall conform to ASTM C-478.
b. Installation
1) The number of extension ring sections shall be kept to a minimum (i.e. use 1-12 inch
extension ring instead of 2-6 inch extension rings).
2) A one (1 ") inch by three and a half (3 1/2") inch bitumastic gasket shall be used to seal the
extension ring at both joints.
4. Rain Pan
a. Materials - Rain pans shall be high density polyethylene plastic.
b. Manufacturers - Knutson or approved equal.
H.U.E
SE\VER SER-"ICE
G. Sewer Services
1. No sewer service line (lateral) shall be less than four (4") inches in nominal diameter.
2. Sewer laterals shall be located at the center of the lot and extended to the property line and be a
minimum of ten (10') feet downstream of the water service. Services will be identified in the field by a
three (3") inch "S" cut into the curb, on the As-Built Plans and with a stake in the field for location
purposes.
3. Sewer service laterals shall have a minimum of four (4') feet of cover at the property line.
4. A cleanout shall be located on the service lateral at the time of connection to the home.
5. Materials
a. All lateral sewer service lines shall be gasketed PVC pipe type SDR-35.
b. All PVC sanitary sewer pipe used for lateral services shall be green in color. (ASTM SPEC)
Chapter 14 - Engineering Design Standards
Page 14 - 27
CoJleyville, Texas, Land Development Code
6. Installation - All service laterals shall be installed in accordance with the sanitary sewer embedment
and backfill standards of the City of Colleyville.
7. Video Insoection Reauired - All sewer service lines that are connected to a section of sewer
service oioinQ located within the riQht-of-wav must have a clean-out installed where the
orooertv line abuts the riQht-of-wav. After the new sewer service line has been connected and
the excavated area is backfilled. the oortion of the sewer service line located within the riQht-
of-way includina the tao into the sewer main must be televised. The video taoe must be
submitted to and aooroved bv the City of Collevville Public Works Deoartment.
8. Point of Connection - The ooint of connection for all sanitary sewer service lines shall be
made to an aooroved oublic sewer main line. No sanitary sewer service line shall directlv
connect to a manhole.
M:.m l.INE Cl:.K'.tI8tlT8
11.U.F
H. Main Line Cleanouts - Cleanouts may be installed on lines that are permanent dead ends. The line may
not exceed two hundred fifty (250') feet. Any line exceeding that length must end with a manhole.
SE\','ER l.Il'lE B8RINb
11.U.C
I. Sewer Line Borinas
1. The design engineer shall design the sewer line pipe casing for the following loading conditions and
applicable combinations thereof:
a. Cooper's E-80 Railway loading or AASHTO HS20 loading as applicable.
b. Earth loading with the height of fill above the casing as shown on the plans.
c. Loads applied during jacking, including axial load from jacking.
d. All other applicable loading conditions, including loads applied during transportation and handling.
2. Materials - fMaterials must meet jurisdictional requirements in all areas, Railroad, TCEQ nJRCC,
TXDOT, etc...t
a. Steel Casing Pipe - Steel casing pipe shall be new (or used if approved by the Director of Public
Works 5e~\'iGe&) and suitable for the purpose intended and shall have a minimum yield strength
of 35,000 psi. Casing shall meet ASTM A-36, ASTM A-570, ASTM A-135, ASTM A-139, or
approved equal. Pipe shall be coated with coal tar epoxy (15 mils min.) in accordance with
AWWA C-210. Pipe joints shall be welded in accordance with AWWA C-206. After pipe is
welded, coating shall be repaired.
b. Cement Mortar - Cement mortar shall consist of one (1) part cement to two (2) parts clean sand
with sufficient water to make a thick, workable mix.
c. Pressure Grout Mix - Grout shall be comprised of one (1) cubic foot of cement and three and a
half (3.5) cubic feet of clean fine sand with sufficient water added to provide a free flowing thick
slurry. If desired to maintain solids in the mixture in suspension, one cubic foot of commercial
grade bentonite may be added to each twelve to fifteen cubic feet of the slurry.
d. Casing Insulators (Spacers) - Use casing insulators for any type of carrier pipe. Insulators shall
be high density polyethylene. Insulators shall fit snug over the carrier pipe and position the
carrier pipe approximately in the center of the casing pipe to provide adequate clearance between
the carrier pipe bell and the casing pipe. Insulators shall be manufactured by "Recon" and be
Racci Type or approved equal.
3. Installation
Chapter 14 - Engineering Design Standards
Page 14 - 28
Col/eyville, Texas, Land Development Code
a. Tolerances
(1) All bores shall be installed at a grade no less that the minimum indicated by TAC, Chapter
317 for the desired pipe size.
(2) All bores shall maintain grade enough to ensure desired clearance distances between
existing utilities and bore.
b. Excavation and Backfill of Access Pits
(1) Bore pits must be a minimum of four (4') feet from the back of curb when located for boring
under roadways.
(2) Do not allow excavation over the limits of the bore or tunnel as specified. Trench walls of
access pits adjacent to the bore or tunnel face shall be truly vertical. Shore the trench walls
as necessary to protect workmen, the public, structures, roadways, and other improvements.
(3) Excavations within the right-of-way and not under surfacing shall be backfilled and
consolidated by mechanical methods as specified in these standards for compaction of
trenches under roadways. Surplus material shall be removed from the right-of-way and the
excavation finished to original grades. Backfill pits immediately after the installation of the
carrier pipe is completed. If carrier pipe is not installed immediately after casing pipe
installation, the right-of-way Owner may require the access pits be temporarily backfilled until
installation of carrier pipe. Plug ends of sleeves to prevent soil migration.
(4) Where seeding or sodding is disturbed by excavation or backfilling operations, such areas
shall be replaced to meet existing or better conditions.
Section 14-170 Drainage and Storm Sewer Improvements
11.11.1.
CEI"JER\h
A. General - This section pertains to general design requirements for drainage and storm sewer
construction in the City of Colleyville. All drainage facilities shall be sized and designed in accordance
with the City of Colleyville Drainage Master Plan or as determined by the Director of Public Works
SePlliees.
11.11.B
R19nQFf C!.hB19h!. TIml~
4.!1..Runoff Calculations - The selection of which method to use for calculating runoff depends upon the size
of the contributing drainage area at the most downstream point of the project. The "Rational Method" is
acceptable for designing projects in which the drainage area is less than one-hundred (100) acres. A unit
hydrograph method is required for projects with larger drainage areas.
1. No matter which method is used to calculate runoff, a developer or builder of residential property
greater than one (1) acre in size, or any property that was platted as a part of an overall tract which
was greater than one (1) acre in size (including churches and schools), shall develop the property so
that the rate of runoff created by the development as it leaves the property does not exceed the rate
of runoff that is currently occurring in the existing conditions. A developer or builder of commercial
property greater than one-half (1/2) acre must follow the above guidelines.
~.2. Runoff computations shall be based upon fully developed watershed conditions in accordance with
the land use projections in the latest comprehensive land use plan for the City of Colleyville. The
design engineer shall size drainage facilities by disregarding the detention effects of upstream
property and calculating the runoff as if the off-site property was developed without any detention. If
an approved regional detention/retention facility is in operation, the design engineer may size
downstream drainage facilities based on consideration of the detention effects of the regional facility.
4.C.Pn~eea~re fer araiRa~e Drainaqe areas less than one-hundred (100) acres
Chapter 14 - Engineering Design Standards
Page 14 - 29
Colleyville, Texas, Land Development Code
aL Computation of Storm water Runoff for drainage areas less than one-hundred (100) acres shall be by
the "Rational Method," which is based on the principle that the maximum rate of runoff from a given
drainage area for an assumed rainfall intensity occurs when all parts of the area are contributing to
the flow at the point of discharge.
J::'.llrl<llT~ll~~.!'!()cJ.~y.f:!I()p~cJ.llll1cJ.m
Developed Park sites
...:$.i~9i.~:!::~iT.iily~~~:i~~ht.illlmm .
.qLlP'I~'.:'m..
.mlll!L1lt.ip'I~I".ll~iIYm ..
Schools
. ..............~...._....~............................
Churches
....................................................................................................................................
..t.'!~!9.h.!?<?Th..<?9.cJ..gg.~'!l~r(;illl. ..
Office Commercial
Co'mmerciiif m ...
............................................. ..
Industrial
. 0
0.70
O:iO
0.85
0.85
Tl::1e ferFJllolla fer QalebllatieR sf rYReff BY tl::1e "Ratisr;lal Metl::1ea" i~: Q - CII'.
\NR9re:
Q - tl::1e FJlaHiFJlIolFJl rate ef ai~eRar!je, eXfilressea iR QYBie feet filer seesRa.
C - CeElffiQiElRt sf RYRSff.
Parl~ areas ~Is aevelsfilsa laml
Oevslsfilea Parl< sites
SiR!jIEl FaFJlily RElsiaeRtial
OYJilIElx
Mblltifille FaFJlily
Sel::1eels
Cl::1l;1rGiI::1Els
~Jei!jI::1Berl::1eea CeFJlFJlElreial
Offie8 CeFJlFJlereial
CeFJlFJler€ial
IRaystrial
Q.AQ
Q.<10
0.59 Q.GQ
9.60
9.79
0.70
0.:0
0.70
0.70
O.Sii
9.Sii
- IRteRsity ef RIoIRSff iR iRGl::1es filer I::1syr (RefereRGe Ql::1art frsFJl tRe Ft. 'JI.'ertl=l
OraiRa!js MaRyal).
A - OraiRa!jEl.'\rEla iR aQre~.
9.2. Time of concentration is the longest time, without interruption of flow by detention devices that a drop
of water takes to flow from the farthest point of the drainage area to the point of concentration (i.e. the
point of design). The time of concentration is composed of the inlet time and the flow time in a
conduit or channel to the point of design.
The inlet time shall be 10 minutes for property zoned multiple family, churches, schools, local
business, central business, commercial, or industrial.
An inlet time of 15 minutes shall be used for property zoned for parks, cemeteries, agricultural, and
single family residential.
When designing inlets and laterals, the time of concentration is equal to the inlet time. The design
engineer will compare the above specified inlet times to the actual calculated inlet time by computing
Chapter 14 - Engineering Design Standards
Page 14 - 30
ColleyvilIe, TexJs, Land Development Code
the flow time overland and along the gutter to the first inlet. Manning's Equation shall be used to
determine flow time to the inlet. The design engineer may use the actual calculated or specified inlet
time. In no case shall a longer inlet time be used than 10 minutes for multiple family, commercial,
churches, schools, industrial and business areas and 15 minutes for parks, cemeteries, agricultural,
and single-family areas.
@.D.PFe@e€hm~s Wf; Drainaqe Areas €lrsGlter tFlGlf! of one-hundred (100) acres or more
ae.1.For drainage areas if! en(@e~~ of one-hundred (100) acres or more where the use of the "Rational
Method" does not provide reliable results, the use of a unit hydrograph method shall be made. The
use of a unit hydrograph calculation will be based upon standard and accepted engineering principles
subject to the approval of the Director of Public Works SSPli@Qs. Acceptable methods include the
Soil Conservation Service (SCS) Technical Release Number 55 or the Corps of Engineers HEC-1
models for drainage areas one-hundred (100) acres or more.
&.2. The unit hydrograph method shall be based upon fully developed watershed conditions assuming no
effects from the small on-site detention facilities for maintaining the rate of runoff as if the property
was undeveloped. The detention effects of large regional detention facilities can be taken into
account in unit hydrograph methods.
9.3. Circumstances that may require the use of a unit hydrograph method include sizing open channels,
reclaiming floodplains, creating lakes, or building other types of drainage-related facilities on major
drainage courses. Design engineers of these types of facilities should be aware that the requirement
of designing for fully developed watershed conditions will mean that they will have to calculate these
fully developed flows instead of using the flows calculated in the Federal Emergency Management
Agency's (FEMA) flood insurance studies for Colleyville or Tarrant County or from studies performed
for or approved by the City of Colleyville.
H.H.C
9EsmN ~T8RI\I FRE€H:TEr'JCIES
E. Deskin Storm Freauencies - All developments submitted must provide data for the following design
storm frequencies: 2-Year 15-Year 110-Year I 25-Year I 50-Year 1100-Year.
1. Drainaae facilities shall be desif:Ined in accordance with the followina table:
Closed Storm Sewer Systems : 5-year with 1 DO-year positive overflow in streets
, such that the depth of flow in the street does not
, exceed the right-of-way or drainage easement
m...mmmm....mmm...Lc;l:iPClC;i!y:mm...m
Closed Storm Sewer Systems 1 DO-year with positive overflow
and Inlets at Street Low Point
...~.r....~.~.9......................................
.....g.1:l..ly~~~...l:J.r:'~..~.r.i.~.g.~.~.....................
Concrete-lined Channels
.......................R.................................................................
Earthen Channels
100- ear
...!99~y~?.r.
1 00- ear
2. The approved drainage system shall provide for positive overflow at all low points and these areas
must be denoted on the plans as such. The term "positive overflow" means that when the inlets do
not function properly or when the design capacity of the conduit is exceeded, the excess flow can be
conveyed overland along a grassed or paved course. Normally, this would mean along a street or
alley, or shall require the dedications of special drainage easements on private property.
11.11.9
STREET .\rID fabl.E'.' C.W.'.CITY
F. Street and Allev Capacity
Chapter 14 - Engineering Design Standards
Page 14 - 31
Colleyville, Texas, Land Development Code
1. Streets - Streets and storm drains within new developments shall be designed so that storm water
runoff resulting from a design storm of a one-hundred (100) year frequency is contained within the
available right-of-way and/or drainage easement. The capacity of the street and right-of-way and/or
easement and the storm sewer pipe working in combination must be designed for a capacity to safely
contain a storm water from a design storm of one-hundred (100) year frequency.
2. Alleys - The flows created by the one-hundred (100) year storm shall be contained within the
capacity of all paved alleys.
11.11.E
Il'll,ET Pl,.'.CEUENT .\ND C\PJ..CIT'..'
4..G. Inlet Placement and Capacity - The storm sewer system is to begin at the point where the storm
water from a five (5) year frequency storm reaches curb depth, with the exception of collector streets on
which storm sewer facilities must be designed to prevent one-twelve (12') foot wide lane from ponding
and on major streets on which storm sewer facilities must be designed to prevent one-twelve (12') foot
wide lane in each direction from ponding. At such point where the combined capacity of the street and
storm drain system satisfies the five (5) year street capacity criteria (as previously described) but the one-
hundred (100) year frequency storm runoff can not be contained within the right-of-way additional pick-up
points (inlet capacity) shall be provided along with an increase in storm sewer capacity so that the one-
hundred (100) year frequency storm runoff will be contained within the right-of-way.
~..1.lnlets shall be placed upstream from an intersection whenever possible. At any intersection, only one
street shall be crossed with surface drainage and this street shall be the lower classified street.
When an alley intersects a street, inlets shall be placed in the alley whenever flow down that alley
would cause the capacity of the intersecting street to be exceeded.
3.2. The minimum inlet size shall be ten (10') feet. No more than twenty (20') feet of inlet shall be placed
along one gutter at any given location. Minimum sizes of laterals shall be twenty-one (21") inches for
use with ten (10') foot inlets, and twenty-four (24") inch laterals with fourteen (14') foot, twenty (20')
foot inlets, and drop inlets. Where laterals tie into trunk lines, place the laterals on a minimum angle
forty-five (450) degrees and a maximum angle of sixty (600) degrees with the trunk line and connect
them so that the longitudinal centers intersect.
4.~Manholes are required every three hundred feet (300'). Junction boxes are required at every change
in flow line direction, change in pipe size, and where a convergence of more than two pipes occurs.
Manholes are to be five feet (5') square and can be precast or cast in place.
11.11.F
PIPE J)ESI€irl ~T.'.1'18".R8S
H. Pipe Deskin Standards
1. Storm sewer conduit shall be sized to flow full. Manning's Equation shall be used to determine the
conduit size.
2. MiRiR:l~FR aRa Ma)(iFR~R:I Desian Velocities iR Pi~E1s
a. +Re minimum '/eleGities iR GeRa~it sRall ee - two and a half feet (2.5') per second.
b. Maximum velsGity iFl tR8 ~i~El st;!all FIst 8HG8El€l- twelve feet (12') per second.
c. The maximum discharge velocities in the pipe shall also not exceed the permitted velocity of the
receiving channel or conduit at the outfall to prevent erosive conditions. The maximum outfall
velocity of a conduit in partial flow shall be computed for partial depth and shall not exceed the
maximum permissible velocity of the receiving channel unless controlled by an appropriate
energy dissipater (e.g. stilling basins, impact basins, riprap protection).
3. In general, storm water shall be carried in concrete pipe conduit within the right-of-way but other
types of conduit can be used to carry stormwater in areas other than the right-of-way. However, prior
permission to use other conduit materials must be obtained from the Director of Public Works
Chapter 14 - Engineering Design Standards
Page 14 - 32
Colleyville, Texas, Land Development Code
SePliGe~.
4. Hydraulic Gradient (also refer to the Ft. Worth Drainage Manual)
a. Conduits must be sized, and slopes must be set, such that runoff flows smoothly down the
drainage system. To insure this smooth passage, the hydraulic gradient must be at the proper
elevations. The hydraulic grade line shall be established and shown on the plans for all storm
sewer design.
b. The hydraulic grade line shall in no case be closer to the surface of the ground or street than one
foot (1 '). The HGL must not exceed the neck into the inlet.
c. Hydraulic gradient calculations shall account for all head losses that may occur in the storm
sewer line. Friction head loss shall be determined by direct application of Manning's Equation.
Minor losses due to turbulence at structures shall be determined using Appendix A of this section.
5. Inspection / Testing
!!:. The compaction of backfill shall meet or exceed 95% Standard Proctor density.
a,. b. All storm sewer conduits shall be inspected prior to acceptance by the City. All conduit forty-two
inch (42") or less shall be inspected using television inspection. Conduits larger than forty-two
inch (42") may be inspected visually.
Do ~ A City representative shall be present during the television inspection.
G. d. Televised Inspection Criteria
(1) All television equipment used shall have a minimum of two-hundred-twenty (220) lines of
horizontal resolution. The picture shall be in color.
(2) All video information on tape must have good picture quality.
(3) As a title heading on the tape and during the televising, the operator must:
k!.:. Note the project name and Contractor name.
"'" ii. Note the name of the company and the operator performing the video inspection.
Uk iii. Note line size and material, joint type and length.
M iv. Line segment to be televised including beginning and ending station numbers.
).k v. Note page of plans used and year plans were stamped.
VJ.. vi. Note date and time of inspection.
vu.. vii. A footage counter must be displayed on the tape during the filming.
vu. viii. Show the above title block before and after each line segment. Show the title
block at one-hundred (100') foot intervals while filming the line segment.
IX. ix. All defects should be shown on film for a minimum of ten (10) seconds before
proceeding with the televising.
(4) The Contractor shall supply a log sheet used in conjunction with the video tape for written
documentation. All written information gathered must be legible and clearly understandable.
k !.:.
"'" ii.
inspection.
tU,. iii. Note pipe size and material, joint type and length between joints.
AI,. iv. Note the VCR tape footage counter, start to end.
~ y:. Note line segment to be televised, station numbers from and station numbers
to length of line segment as indicated on plans.
~ vi. Note page of plans used and year plans were stamped.
~ vii. Note date and time of inspection.
VUkviii. Indicate by sketch the line segment to be televised in relation to surrounding
road intersections and street addresses. Identify manhole station numbers. Show
Note the project name, Contractor name and contract number.
Note the name of the company and the operator performing the video
Chapter 14 - Engineering Design Standards
Page 14 - 33
Colleyville, Texas, Land Development Code
direction of flow with arrows and direction the camera is going. Indicate direction of north
on the sketch.
~ ix. Note the water depth at the beginning, every fifty (50') foot station, every
change in grade, and at the end of the line segment.
X. & Identify the clock location, direction, size and type of laterals entering main.
Indicate laterals as saddles, punched, or glued fittings.
XJ.. xi. Indicate final footage televised at end of the log sheet.
9.5. One tape per visual televised inspection project shall be furnished to the Project Inspector.
.7.~Tapes must be VHS format, one (1") inch wide T-120, high quality tape. Tapes are to be
recorded on SP (2 hours) play.
i.7. All tapes and run sheets shall be submitted to the City. All tapes and log sheets shall
become the property of the City.
11.11.C
Cl:Tl:. ':ERT DE~u;J~1
I. Culvert Desian
1. One (1 ') foot of freeboard is required between the one-hundred (100) year water surface elevation
and the top of curb elevation. Exceptions must be approved in writing by the Director of Public
SBPli€ieG Works.
2. Culverts must be designed using standard engineering practices and engineering judgement.
Culverts shall be designed in accordance with the latest edition of the City of Fort Worth Drainage
Manual. If the City of Fort Worth Drainage Manual does not incorporate the necessary standards
please refer to the Texas Department of Transportation (TxDOT) Hydraulic Design Manual.
3. Culvert hydraulic grade line calculations shall consider both inlet and outlet control.
4. Culverts shall be eke'uB€! eWGR tRat iml'laGt~ €!WQ te tRe flee€! aR€! Rermal fie'!: aR~lee sf attaGI( SF! tRe
GtrwEltwre are miRimize€! aliQned to provide the minimum resistance to the flow of water durina
the 10. 50. 100 and 500 year events.
5. The maximum velocity through a culvert shall be fifteen (15') feet per second.
6. Stream stability shall be assessed when determining the number of barrels, height and width and
culvert skew. Potential for scour shall be accounted for in the design.
7. Hydraulic jumps shall not be allowed from face of culvert to fifty (50') ten (10') feet from the culvert,
subiect to the approval of the Director of Public Works.
11.11.11 BRIBfJES
!. J. BridQes - Two (2') feet of freeboard is required between the one-hundred (100) year water
surface elevation and the low chord of the bridge. Exceptions to this requirement must be approved by
the Director of Public Works SepjiGe~ in writing.
~.1.:. The skew of the bridge piers and abutments shall be oriented as close to the normal or flood direction
of flow resulting in an angle of attack as close to zero (0) degrees as possible.
2. BridQe piers shall be aliQned to provide the minimum resistance to the flow of water durina
the 10. 50, 100 and 500 year events.
3. Computer modeling programs used for the hydraulic analysis of bridges shall be HEC-RAS, Version
2.2. or HEC2.
Chapter 14 - Engineering Design Standards
Page 14 - 34
Colleyville, Texas, Land Development Code
4. Stream stability shall be assessed when designing the abutments and interior bents of the bridge.
Scour shall be accounted for in the design.
5. Fie',,' sl:lall Ret B9 Where flows are supercritical, erosion control measures shall be used in an
area from one-hundred (100') feet upstream from a bridge to twenty-five (25') feet downstream from a
bridge.
CILHIr'IEJ,$
11.11.1
t. K. Channels - Open channels may be used instead of an enclosed system when a pipe greater
than an eighty-four (84") inch diameter (or other shape equivalent to more than thirty-eight and a half
(38.5) square feet) is required to carry the design storm event.
~..1..o~8R Cl:laRRel Design Criteria:
a. All open channel design must follow the Corp of Engineers Guidelines.
b. Channels may be left in their natural state provided that the channel velocities are six (6.0') feet
per second or less and that one (1') foot of freeboard is available during the design storm event.
c. If the natural channel is to be replaced by an improved channel, the flow from the one-hundred
(100') year design flood must be contained within the improved channel while allowing for one (1')
foot of freeboard.
d. Improved channels shall be trapezoidal shaped and include a lined section if the design velocity
is greater than six feet per second. Lining types such as concrete, rock walls and gabions may
be used upon approval of the Director of Public Works ~9rviQ9~. The maximum velocity allowed
in concrete lined channels is fifteen (15') feet per second.
e. Unless shown to be feasible in a soils report sealed by a licensed professional engineer in the
State of Texas, and approved by the Director of Public Works ~erVi€l9S, improved channels shall
have minimum side slopes of:
ill 4 feet horizontal to 1 foot vertical for earthen, grassed-lined side slopes.
m 2 feet horizontal to 1 foot vertical for concrete-lined side slopes iR ~9€l1~.
f. Where practicable, all unpaved channels should have sufficient grade to avoid ponding. A
minimum slope of ~ 1.00% is required for earthen channels and swales, except those used
as part of a wetlands area. In areas where ~ 1.00% cannot be obtained a pilot channel
approved by the City may be used. All lined channels are to have a minimum slope of 0.50% and
~ earthen channels a minimum slope of 1.00%.
g. The developer or owner shall use low maintenance vegetation for vegetative cover, as approved
by the Director of Public Works ~9rviQe~ prior to planting. The selection of materials shall
comply with eitAef; the current ground cover listing for North Central Texas furnished through the
Texas Agricultural Extension Service.
a..2. Manning's Equation can be used to design channels and determine water surface elevations and
velocities when backwater effects are negligible, subiect to approval bv the Director of Public
Works. Channels where backwater effects occur must be designed using models accepted by
FEMA.
4.3. All channel sections must consider and account for channel stabilization in their design. This
requirement pertains to all sections whether they are left in their natural condition or are modified in
any manner. The design of all drainage channels and swales shall assure adequate capacity and
minimum maintenance to overcome the result of erosion, silting, sloughing of bends or similar
occurrences.
fF.4. When performing hydraulic analyses for channel or drainageway design, the one-hundred year (100)
Chapter 14 - Engineering Design Standards
Page 14 - 35
Colleyville, Texas, Land Development Code
year starting water surface shall be based on the following:
a. Known water surface elevations should be used where possible. Known elevations are available
for some creeks and channels from previous studies approved by the City.
b. When known water surface elevations are not available the slope-area method or a rating curve
may be used.
(1) A rating curve approximates the starting water surface elevation for a given flow by using the
relationship between known flows and water surface elevations for the creek. This is an
excellent method for determining starting conditions if good data is available to develop the
rating curve.
(2) The slope-area method approximates the starting water surface elevation by calculating the
normal depth for the channel. To calculate normal depth the slope of energy gradient for the
channel is required. The energy slope can be approximated using the average slope of the
channel or the average slope of the water surface.
9.5. The design of the channel lining shall take into account the super-elevation of the water surface
around curves and other changes in direction. In general a radius that is three (3) times the top width
of the water surface during the design storm event is recommended for channel bends.
+'6. A chain link fence six (6') feet in height, or other improvements as approved on a case by case basis
by the Director of Public Works SerVi€BS, shall be constructed on each side of the lined channel.
3.7. Gabion or other forms of channel lining a~El ~ref9rrBel may be used in lieu of reinforced concrete
lining with the approval of the Director of Public ~er.ti€ie& Works.
11.11.J
DEl'EI'ITI€1rl :DE~mr>1
L. Detention DesiQn - Runoff rates for all land uses shall be limited to the rates that would be produced
from single family residential areas. This requirement also applies to the development of sites as
churches, schools, and other institutional uses. Detention/retention facilities shall be designed for the
fully developed one-hundred (100) year design flood according to the following criteria:
1. The minimum amount of storage volume of the detention basin shall be that volume required to
reduce runoff rate durinQ the 100 year event to the undeveloped rate. The outflow structure shall
be sized to reduce the 2. 5. 10. 25. 50. and 100 year discharQes to the undeveloped rate.
Dedicated detention/retention basins shall also include an additional one foot of freeboard and two
feet of sediment storage. The volume of runoff storage for drainage areas greater than one-hundred
(100) acres shall be computed using unit hydrograph procedures. Acceptable unit hydrograph
procedures are provided in Section 14-170.D.114.S.~.5 of this document.
For drainage areas less than one-hundred (100) acres, the above methods are recommended;
however, an approximate routing method based on the modified rational method fGrmlolla is
allowable.
2. All detention facilities designed shall consider the timing of the flood peak in the main channel into
which the detention facility drains. Delaying the peak from a site in lower portions of a watershed
may result in a higher peak on the main channel. The Director of Public Works may reauire that
upstream and downstream ponds be included in the detention desiQn model.
3. A detention facility shall have enough gradient to ensure positive drainage to the outlet structures so
as to avoid nuisance conditions such as standing water, odors, insects, and weeds. A minimum slope
of 0.50% towards the outlet structure is required for all grass lined detention facilities.
4. Detention areas in parking lots shall not be:
a. In required parking spaces.
b. Behind speed bumps unless the speed bumps are made with reinforced concrete.
Chapter 14 - Engineering Design Standards
Page 14 - 36
Colleyville, Texas, Land Development Code
c. Deeper than six (6") inches unless otherwise approved by the Director of Public Works Servises.
5. Drainage easements shall be provided for all regional detention/retention facilities and for other
detention/retention facilities where two or more owners are involved.
6. Individual Qgetention facilities shall be designed to empty in less than three (3) tv/aRty fe~r ~24)
hours, unless it is also serving as an erosion control facility.
7. Detention facilities used as a sediment control facility ~ shall meet the following requirements;
a. The sediment control facility shall be designed with minimal velocities such that sediment is
dropped and not picked up by flows at any time during the storm event.
b. The basin shall be designed with i3€le~~G1te two (2) feet of sediment storage area so that
sediment removal is not required more than twice a year. Expected removal periods greater than
twice a year must be specified in the maintenance plan and approved by the Director of Public
Works S8r;\'ise~.
c. Sediment control facilities cannot be used to meet detention requirements unless the volume of
sediment is included in the calculations for the detention basin design.
8. The owner shall maintain detention/retention facilities unless the facilities are dedicated to the City of
Colleyville. Detention facilities must be properly maintained if they are to function as intended over a
long period of time. The following measures are required to ensure the facility functions properly.
a. Facilities should be mowed at least twice a year to control weeds and discourage woody growth.
b. Debris, litter and accumulated sediment should be removed from detention facilities at least twice
a year. Particular attention should be given to removal of debris, litter and sediment around outlet
structures. The Director of Public Works may reauire that the property owner remove said
debris when in the Director's determination that property damage or a flood hazard may
exist.
c. Detention basins designed for sediment removal shall be maintained as specified in the
maintenance plan and approved by the City with construction plan submittal.
1 ~.1 i.K Fh\:Jl'\fES
4.. M. Flumes - The use of flumes is not recommended for widespread use. Flumes shall not be permitted
when the purpose of a permanent flume is to carry runoff down the sides of earthen channels.
;;!.1:,A flume may be used to direct overflow runoff along property lines until the runoff can be intercepted
by streets or conduits. A flume shall not carry more than ten (10) cubic feet per second during the
one-hundred (100) year storm event with a slope of 1.00%.
a.2. All flumes crossing sidewalks shall be covered or bridged such as to minimize danger to pedestrians.
4.3. All edges are to be protected with rock rip-rap or other form of protection for erosion control and scour
purposes.
1 i.l ~.l.
l..\H.ES
N. Lakes - Approval to develop in any area subject to inundation by a lake must be obtained from the
appropriate agency responsible for that particular lake before the city grants its approval. Agencies that
should be contacted include U.S. Army Corps of Engineers, Tarrant County Water Control Board, TCEQ
nIRCC, the Trinity River Authority, and FEMA.
Regardless of approvals obtained from those agencies listed above, no filling, development or
construction in any area subject to inundation by a lake shall occur without the approval of the City
Chapter 14 - Engineering Design Standards
Page 14 - 37
Colleyville, Texas, Land Development Code
Manager. The City Manager may require any studies necessary to determine that filling, development or
construction will not have a detrimental effect on adjacent, upstream or downstream properties and
buildings. This subsection in no way diminishes other requirements of this section.
1 ~.1 O\f l.QT Iln':.I]\J.\€lE ,HID CI1.\DII'I€l
4.. O. Lot DrainaQe and Grading - Grading and drainage of all residential lots shall be designed in a
manner which will allow one lot to drain across an adjacent lot and into a permanent structure, such as a
concrete flume, lined channel, or proper inlet to an adequate drainage facility, or to a street right-of-way.
If an approved drainage structure is not present, it will be required of the developer to construct the
necessary facilities. (0-00-1261/12/19/00)
;;!.1:, Sheet flow techniques shall be used for lot to lot drainage where possible. (0-00-1261/12/19/00)
a.2. Single lots shall accommodate their own drainage into an approved structure where topographic
elevations allow this to occur. (0-00-1261/12/19/00)
Section 14-175 Miscellaneous
1 i.U.I_
TREl"ICII K\fETY
A. Trench Safety - In conformance with House Bills 662 and 665 as passed by the Seventieth Legislature
Regular Session of the State of Texas, all construction projects within the City of Colleyville or its
extraterritorial jurisdiction as provided by the Municipal Annexation Act (Article 970a, Vernon's Texas Civil
Statutes) shall contain provisions for trench safety. On construction projects in which trench excavation
will exceed a depth of five (5) feet, the uniform set of general conditions must require that the bid
documents and the contract include detailed plans and specifications for adequate safety systems that
meet Occupational Safety and Health Administration standards and that these plans and specifications
include a pay item for these same safety systems.
li.U.B
UI'IDER€lRQ~]\)D lJTIUTIES
B. UnderQround Utilities - All distribution lines, cables, etc. for utilities other than those listed above
shall be installed below ground within the subdivision. Transmission lines or major cables to provide
utilities such as electric, telephone, and cable television to the area as a whole may be located above
ground on the perimeter of the subdivision being served. The installation of these utilities shall conform to
commonly accepted construction standards and be subject to review by the Director of Public Works
Ser;\.'i€le~.
Section 14-180 Drainage Studies and Engineering Certification
1 i.l'.)..
PREUl\UN:.R'.' :DR\IN:.€lE Ann. YSIS CUlDEUI'IES
A. Preliminary Drainage Analysis Guidelines - The purpose of a Preliminary Drainage Analysis is to
determine the need for drainage facilities and/or drainage easements either within the proposed
development or offsite. A Preliminary Drainage Analysis is required for every subdivision plat or a
development requesting a building permit on a parcel which does not have a previously approved
drainage analysis, unless the sit:! 8R~iReElr Director of Public Works has waived this requirement due to
existing conditions. The Preliminary Drainage Analysis shall consist of the following information:
1. A topographical map drawn at a scale of I" = 200' which depicts the watershed that drains to and
across the subdivision or development. The map must include the subdivision and an area extending
a minimum of 200' in all directions from the proposed subdivision. Sheets shall be either 18" X 24" or
24" X 36" in size and may contain sheet to sheet match lines. The map must include contour lines at
five (5') foot vertical intervals in terrain with a slope of two (2%) percent or more, or two (2') foot
vertical intervals in terrain with a slope of less than two (2%) percent. Data from the City topographic
Chapter 14 - Engineering Design Standards
Page 14 - 38
Colleyville, Texas, Land Development Code
maps will be acceptable where available. Data from USGS Quad sheets may be acceptable only
where City topographic maps are not available. The datum for "0" topography shall be that of the
United States Coast and Geodetic Surveyor the City of Colleyville GIS datum.
The map shall indicate any offsite or adjoining areas outside the limits of the area being developed
which are relevant to onsite drainage. Show all significant physical features such as proposed or
existing drainage and utility easements, water bodies, streams, railroads, parks, and drainage
ditches. Show location of existing utilities including gas and petroleum lines, electric, telephone and
TV cable. Also, the location of any existing structures located within the area being proposed for
development. The plan shall include the building footprint and parking areas when the Preliminary
Drainage Analysis is prepared for a building permit.
2. Calculation of the drainage areas, time of concentration, and storm water runoff rate for the 2. 5. 10.
25. 50 and 100 year frequency storms. The design calculations shall include preliminary locations of
drainage facilities.
(0-00-1261/12/19/00)
3. Identification of special flood hazard areas as defined by the Flood Hazard Area Regulations
Ordinance and as located by the current Flood Insurance Rate Map.
4. The Preliminary Drainage Analysis shall be sealed by a Registered professional Engineer licensed by
the State of Texas.
:DR'.In\GE STYDY ClHDEUI'JES
1 ~.lti.B
B. DrainaQe Study Guidelines - A Drainage Study is required when it has been determined by the 6ity
eFl~iReE:H Director of Public Works that the area being developed will require storm water drainage
facilities or drainage easements either within the development or offsite. The following criteria shall be
used for the developer's engineer to prepare a Drainage Study.
1. The study shall analyze the effect of the subdivision or the development on existing downstream
drainage facilities. The study shall be sufficient to verify compliance with the drainage design criteria
contained in this chapter.
2. The study shall include a topographical map as defined above in "Preliminary Drainage Analysis
Guidelines."
3. Delineation and calculation of drainage areas together with proposed flow arrows shall represent flow
patterns from runoff after all proposed improvements have been installed. Surface water drainage
patterns shall be shown for each and every lot in the proposed subdivision and for each lot adjacent
to the proposed subdivision.
4. In addition to those calculations required by the Preliminary Drainage Analysis, this study shall also
include:
a. Hydraulic calculations to each lateral, manhole, inlet and outlet structure on the pipe. Head
losses shall be calculated as described elsewhere in this chapter.
b. Inlet calculations utilizing the minimum time of concentration for the zoning type which is
contributing the largest "CA" to the inlet.
5. If any portion of the proposed subdivision or its offsite improvements (including pipes or ditches) fall
within the limits of a Federal Emergency Management Agency (FEMA) floodplain, additional
backwater calculations may be required. Additional calculations in the form of a Conditional Letter of
Map Revision will be required if:
a. Any portion of the proposed subdivision is determined to be located within a FEMA Zone "A"
floodplain; or
b. Any portion of the proposed subdivision is determined to be located within a FEMA Zone "AE"
Chapter 14 - Engineering Design Standards
Page 14 - 39
Colleyville, Texas, Land Development Code
floodplain and the overall subdivision (including all phases) is 5 acres or larger; or
c. Any portion of the proposed improvements from a subdivision include dredging or filling within a
FEMA designated floodway.
6. Backwater calculations shall comply with normally accepted standards as required by FEMA
for application for a Letter of Map Revision (LOMR). In addition, the calculations must begin with a
previously defined Base Flood Elevation (BFE). The calculations shall continue upstream through the
project until the proposed BFE is within .01 feet of the existing BFE or the limits of the existing Zone
'A' have been reached. A LOMR will be required prior to issuing building permits.
1 ~.lti.C
CERTIFIC!. TIS!'l
C. Certification - All drainage studies and/or plans including those which are part of a standard construction
plan submittal shall be sealed and signed by an engineer proficient in civil engineering and registered in
the State of Texas. All drainage submittals shall include the following certifying statement by the
"Engineer of Record".
I a Professional Engineer r8!!jistere& licensed in the State of Texas have
prepared this drainage study and/or plan in compliance with the latest published requirements and criteria of the
. City of Colleyville, and have verified that the topographic information used in this study and/or plan is in
i compliance with said requirements and is otherwise suitable for developing this workable plan of drainage which
: can be implemented through proper subsequent detailed construction planning.
I Signature
.........................m......................... .
P.E., (S~~I)
:DI~Cl:..\.Il\IER QF l.UBIUTY
1 ~.I'.:D
D. Disclaimer of Liability - The degree of flood protection required by this policy is considered reasonable
for regulatory purposes and is based on scientific and engineering considerations. On rare occasions
greater floods can and will occur and flood heights may be increased by man-made or natural causes.
This policy does not imply that land outside the areas of street rights-of-way, drainage or flood plain
easements will be free from flooding or flood damages. This policy shall not create liability on the part of
the City of Colleyville, Texas or any official or employee thereof for any flood damages that result from
reliance on this policy or any administrative decision lawfully made thereunder.
Section 14-185 Amendments to This Chapter
Reserved for listing of amendments to this Chapter.
Ord. Number
0-00-1261
Date
12/19/00
0-01-1280
01/08/01
Chapter 14 - Engineering Design Standards
Page 14 - 40
ORDINANCE 0-03-1403
AN ORDINANCE OF THE CITY OF COLLEYVILLE, TEXAS, AMENDING
CHAPTER 14 - ENGINEERING DESIGN STANDARDS, OF THE LAND
DEVELOPMENT CODE; PROVIDING A SAVINGS CLAUSE; PROVIDING A
SEVERABILITY CLAUSE; PROVIDING A PENALTY CLAUSE; AND
AUTHORIZING PUBLICATION.
WHEREAS, the City Council of the City of Colleyville approved Ordinance 0-00-
1214 on April 18, 2000, to adopt the Land Development Code; and
WHEREAS, the City Council of the City of Colleyville desires to amend certain
portions of the Land Development Code; and
WHEREAS, notice of a public hearing before the City Council was published in
a newspaper of general circulation in Colleyville at least 15 days
before such hearing.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY
OF COLLEYVILLE, TEXAS:
Sec 1.
Sec2.
Sec3.
Sec4.
THAT Chapter 14 - Engineering Design Standards, of the Land
Development Code, as amended, is hereby amended in its entirety
to read as shown on the attached Exhibit "A".
THAT Ordinance 0-00-1214, the Land Development Code, as
amended, shall remain in effect, except where amended by this
ordinance.
THAT it is hereby declared to be the intention of the City Council that
the phrases, clauses, sentences, paragraphs, and sections of this
ordinance are severable, and if any phrase, clause, sentence,
paragraph or section of this ordinance shall be declared
unconstitutional by the valid judgement or decree of any court of
competent jurisdiction, such unconstitutionality shall not affect any of
the remaining phrases, clauses, sentences, paragraphs and sections
of this ordinance, since the same would have been enacted by the
City Council without the incorporation in this ordinance of any such
unconstitutional phrase, clause, sentence, paragraph or section.
THAT any person, firm or corporation violating any of the provisions
of this ordinance shall be guilty of a misdemeanor and upon
conviction thereof shall be fined a sum not to exceed Two Thousand
Dollars ($2,000.00). Each and every day such violation continues
Ordinance 0-03-1403
Page 2 of 2
shall constitute a separate offense and shall be punishable as such.
Sec 5.
THAT the City Secretary is hereby authorized and directed to cause
publication of the descriptive caption and penalty clause hereof as an
alternate method of publication provided by law.
AND IT IS SO ORDERED.
The first reading and public hearing being conducted on the
2003.
day of
The second reading and public hearing being conducted on the
2003.
day of
ATTEST:
CITY OF COLLEYVILLE:
Cynthia Singleton, TRMC
City Secretary
Mayor
APPROVED AS TO FORM AND LEGALITY:
Ross 1. Foster
City Attorney
Exhibit "A"
Chapter 14 - Engineering Design Standards
Colleyville Land Development Code
Colleyville, Texas, Land Development Code
Section 14-100 Purpose of Ihis Chapter
The purpose of this Chapter is to establish minimum standards and construction details for all public facility
improvements.
Section 14-105 Authorization for Adoption of This Chapter
The regulations contained in this Chapter have been adopted under the following authority:
A. Chapter 212 - Municipal Regulation of Subdivisions and Property Development of the Texas Local
Government Code, which authorizes a municipality to adopt rules governing plats and subdivisions of
land within the municipality's jurisdiction.
B. Chapter 51 - General Powers of Municipalities of the Texas Local Government Code, which authorizes a
municipality to adopt ordinances, rules, or police regulations that are for the good government, peace, or
the trade and commerce of the municipality.
C. The Home Rule Charter of the City of Co/leyville, which authorizes the City Council to exercise all powers
granted to municipalities by the Constitution or the laws of the State of Texas.
Section 14-110 Applicability of This Chapter
The provisions of this Chapter shall be applicable to all public improvements owned and maintained by the
City of Colleyville and to any semi-public improvements owned and maintained by a property owner's
association that are intended to serve and function as a public improvement.
Section 14-115 Variances and Appeals
A. The Director of Public Works may consider an alternative proposal of a regulation contained in this
Chapter in order to achieve the best overall design. When considering such a proposal, the Director of
Public Works shall determine that the approval, disapproval or modification will not be detrimental to the
public safety, health, or welfare or injurious to other property and is consistent with sound engineering
practices. The applicant shall provide information to support a claim that the public interest may be better
served by an alternative proposal.
B. Any person seeking approval of a development may appeal a decision of the Director of Public Works
regarding the regulations contained in this Chapter by using the procedures described in Chapter 1 -
General Provisions of this Land Development Code.
Section 14-120 General Conditions
A. "COG" and "TXDOT" Specifications - All drawings and details contained in Chapter 15 - Public Works
Construction Details which include references to "item numbers", "specs" and "types" shall be governed
by the latest version of "Standard Specifications for Public Works Construction, North Central Texas" of
the North Central Texas Council of Governments ("COG"), with all amendments thereto, and shall
constitute the technical specifications, except as amended by this Land Development Code, and made a
part thereof, but not physically bound within this document. Streets shall be designed in accordance with
Chapter 14 - Engineering Design Standards
Page 14 - 1
Colleyville, Texas, Land Development Code
the most current edition of The Texas Department of Transportation's Highway Design Division
Operations and Procedures Manual, AASHTO's A Policy on Geometric Design of Highways and Streets,
and the Transportation Research Board's Highway Capacity Manual.
B. Acceptance of Improvements - No public improvements shall be accepted by the City or its
representatives, unless and until such improvements conform to this Land Development Code and all
other applicable standards as prescribed by the City of Colleyville. All streets, alleys, sidewalks,
drainage-ways, signage, water and sewer lines and all other public improvements shall be designed,
placed and constructed in accordance with the design criteria contained in this Land Development Code.
C. Plan Review and Inspection Fees - Prior to the acceptance by the City of any public improvements, the
developer shall pay the City a plan review fee and an inspection fee as follows:
1. Engineering Plan Review Fee - 2% of the actual cost of the public improvements
2. Engineering Inspection Fee - 3% of the actual cost of the public improvements
D. Citv-Developer Aqreements
1. Requirement - When it is proposed that the City will share in the costs with a developer for the
construction of public improvements, no public improvements shall be constructed within a
development, unless and until a City-Developer Agreement has been approved by the City Council.
Where the public improvements are a requirement of a subdivision plat approval, the City-Developer
Agreement shall be submitted to the City Council for approval at the same time as the plat submittal,
or as soon thereafter as practical. (0-00-1261/12/19/00)
2. City Participation - The City may share in the costs with a developer for constructing public
improvements relating to a development, provided a City-Developer Agreement has been approved
by the City Council in accordance with this Section. The limits of City participation shall be expressly
established in the agreement at a level not to exceed thirty (30) percent of the total contract price.
Under the agreement, the developer shall construct the public improvements and the City shall
participate in the costs. Where a developer is requesting City participation in the construction of a
public facility and the total participation cost by the City exceeds twenty-five thousand ($25,000)
dollars, the procurement procedures specified in the Texas Local Government Code for public
improvements shall be used by the developer. All records to the developer's cost of constructing the
public improvements shall be maintained and made available for inspection by the City. (0-00-1261/
12/19/00)
3. Construction Plans - It shall be the responsibility of the developer's engineer to prepare all
engineering construction plans and contract documents for construction of the project for the use of
the City and the contractor. (0-00-1261/12/19/00)
4. Performance Bond - Where a City-Developer Agreement has been authorized, the developer shall
execute a performance bond for the construction of the public improvements which shall include any
City participation to ensure their completion. (0-00-1261/12/19/00)
5. Authorization to Proceed - On projects not requiring a City-Developer Agreement, the developer may
proceed with the construction of the public improvements after the City has issued a letter authorizing
the developer to proceed with the construction, provided the engineering construction plans have
been approved by the Director of Public Works. All construction shall be in accordance with the
applicable sections of this Land Development Code. The developer may select his own contractor
subject to the contractor executing the necessary bonds with the City and payment of the inspection
fees required for each portion of the public facilities. (0-00-1261/12/19/00)
Section 14-125 Construction Plan Requirements
The purpose of this Section is to specify the minimum construction drawing requirements for all public
improvement projects, including public improvements associated with a proposed subdivision or commercial
development. All construction plans for public water, sanitary sewer, street, drainage and traffic improvements
Chapter 14 - Engineering Design Standards
Page 14 - 2
Colleyville, Texas, Land Development Code
shall be designed, signed, sealed, and dated by a Registered Professional Engineer licensed in the State of
Texas. All construction plans or drawings must be accompanied by a Geotech Report signed, sealed, and
dated by a Registered Professional Engineer licensed in the State of Texas. Plans and drawings shall adhere
to the requirements in this Section and be furnished in the format listed herein:
A. General Requirement - No construction of any public improvement shall commence, unless and until the
construction plans for the proposed public improvement has been approved by the Director of Public
Works or designee.
B. Number of Copies - No construction of any public improvement shall commence, unless and until the
construction plans for the proposed public improvement has been approved by the Director of Public
Works or designee.
C. Cover Sheet
1 . project title
2. property legal description, if applicable
3. city name
4. vicinity map
5. owner, engineer, and surveyor name, address and telephone number
6. project title in small print placed vertically along the right border
7. sheet index
8. signature block for City approval
D. Copv of Current Plat - When construction plans are related to a new subdivision or a commercial
development, a copy of the current plat shall be bound with the construction plans. The signed plat shall
be bound with the as-built drawings.
E. Drainaqe Area Map - The drainage area map is critical to all drainage designs, since the ultimate layout,
sizing and hydraulic analysis is dependent upon a thorough review of the proposed development. This
map should be accompanied with all drainage calculations. The Drainage Area Map must show the
physical features of the site that either exist or are proposed, including the existing and proposed
contours, existing and proposed storm sewers, and/or other drainage facilities. Commercial projects
should include the locations of buildings, flatwork and pavement.
F. Site Plan - The developer of a commercial project shall submit a site plan indicating the location and
width of all proposed and existing street and driveway approaches noting the back-of-curb radii.
G. Utilitv Plan - This drawing shall indicate the location and size of all existing and proposed water and
sanitary sewer lines with adjacent existing or proposed top of curb grades. Show the location of all
existing and proposed fire hydrants adjacent to the site including the maximum coverage radius of each
as outlined in later sections of this manual.
H. Plan and Profile Sheets - Plan and profile drawings shall be required for roads, sewers, storm sewers,
channels, flumes, and water lines twelve (12") inches in diameter and larger. Stationing shall be generally
left to right and with stationing beginning at the downstream end for all sewers, storm sewers, and
channels. Stationing shall be included on the plan view as well as the profile for all roads, water, sewer,
storm sewer and channel sheets. Elevations shall be calculated and provided on all profiles as indicated
below.
1. Straight grade - provide elevations at a maximum interval of 50 feet.
2. Vertical curve - provide elevations at the beginning and ending points and at a maximum interval of
25 feet in between.
I. Plan & Profile Sheet Size - Plan and profile sheets shall not exceed twenty-four (24") inches wide by
thirty-six (36") inches long. Horizontal scale shall be one (1") inch equals fifty (50') feet or larger, i.e. 1" =
40'. Vertical scale shall be one (1") inch equals five (5') feet or larger.
J. Details - Drawing details shall be included with all construction plans to clarify proposed construction
Chapter 14 - Engineering Design Standards
Page 14 - 3
Colleyville, Texas, Land Development Code
specifications and said details shall be consistent with Chapter 15 of this Land Development Code.
K. Plottino Drainaqe Features - Appropriate hydraulic grade line or water surface profile shall be plotted with
all drainage designs. Capacity, design discharge, velocity, and velocity head shall be noted on each
segment of a drainage facility in the profile whenever one or more of these parameters changes.
L. Erosion Control Plan - The developer of a subdivision or a commercial project shall submit an erosion
control plan in accordance with the requirements of Chapter 12 - Erosion Control.
M. Storm Water Pollution Prevention Plan - The developer of a subdivision or a commercial project shall
submit a storm water pollution prevention plan in accordance with the requirements of the Texas
Commission on Environmental Quality.
N. Street Sion Plan - showing the location of all proposed street name signs and traffic control signs. The
street sign plan shall include an elevation view of each street sign indicating the type and color of each
sign. All signs shall comply with the requirements of the latest edition of the Texas Manual on Uniform
Traffic Control Devices. Refer to street sign standards, located elsewhere in this Land Development
Code (Section 14-145).
O. City Review and Approval Process - All construction plans for public improvements shall be reviewed by
city staff for compliance with this Section and with any applicable guidelines of other agencies. City staff
shall provide written comments to the developer and the developer shall respond to all city comments.
The Director of Public Works, or designee, shall not approve any construction plans until all comments
have been resolved and the construction plans determined to be acceptable to the city. All approved
construction plans shall be signed by the Director of Public Works, or designee, and no construction work
shall commence until a pre-construction meeting has been held and a letter of authorization to proceed
has been issued by the Director of Public Works. Development projects which have not started within
one year from the date of approval of the construction plans shall require a new review.
Section 14-130 Street Design Criteria
A. Rioht-of-Wav Widths - The right-of-way widths for any proposed street shall be designed for the intended
use and anticipated traffic volume at optimum development of the area served. Additional right-of-way
may be required at street intersections and to provide for left and right turn lanes at high-volume
intersections. The following table shall be used as a guide in determining right-of-way widths.
Local R2U 50 (2) 15 30 2
Cul-de-sac R2U 50 (3) 18 36 (3) 2
Minor Collector C2U 75 12 42 2 wI 9' parking or
3 wlo arkin
Major Collector (two lane) C3U 75 12 42 2 wI 9' parking or
3 wlo arkin
Major Collector (four lane) C4U 80 12 48 4 undivided
Minor Arterial M4D 95 13 52 4 divided
P4D 120 13 52 4 divided
Prima Arterial \ S. H. 26 P6D 120 12 76 6 divided
(1 ) Street classification refers to the functional classification shown on the Master Thoroughfare Plan.
Chapter 14 - Engineering Design Standards
Page 14 - 4
Colleyville, Texas, Land Development Code
(2) A local street having a total length in excess ot one thousand two hundred (1,200) teet or serving
more than thirty (30) dwelling units may be required to provide a right-ot-way width ot not less than
sixty (60) teet.
(3) A cul-de-sac street exceeding 600 teet in length shall have a 56' right-ot-way and 36' ot pavement.
B. Desion Speed and Maximum Grade - All streets shall be designed to conform to the following
parameters:
Local 30 8 0.5
...."1" ................................. i.........................................
C2.1.1.~~2.~..m.mm.: 30 6 0.5____Q':l_~.!~I.1_e or center 12'
Arterial 40 4 0.5! One lane in each direction
(1) The Director ot Public Works may approve an alternate design.
Section 14-135 Driveway Spacing and Design Standards
A. Residential Construction - Residential driveway approaches shall be constructed of six (6") inch thick
three thousand five hundred (3,500) psi compressive strength concrete reinforced with #3 steel bars on
eighteen (18") inch centers each way, with #4 bars doweled into the existing concrete paving..
Residential driveways shall be constructed with the return curbs having a rolled face disappearing at the
sidewalk and joining the street curb.
B. Commercial and Industrial Construction - Commercial and industrial driveway approaches shall be
constructed of six (6") inch thick three thousand five hundred (3,500) psi compressive strength concrete
reinforced with #4 steel bars on eighteen (18") inch centers each way, with #4 bars doweled into the
existing concrete paving. Commercial and industrial driveways shall be constructed with the return curbs
having a rolled face disappearing at the sidewalk and joining the street curb.
C. Drivewav Approach Depth - The driveway shall begin at the street curb and extend to the property line or
to a point nine and one-half (9.5') feet from the back of the curb, whichever is greater. The drive
approach shall be constructed such that the height of the drive approach at the property ROW, with a
typical nine and one-half (9.5') foot parkway, shall be two and one-half (2-1/2") inches higher than the top
of the curb. The tangency point of a driveway curb shall be a minimum of ten (10) feet from a storm water
inlet.
D. Drivewav Approach Widths and 5pacino - The criteria contained in the following table shall be the
minimum and/or maximum standards to be applied in spacing and designing driveways on public streets.
For the purpose of this regulation, driveway width shall be measured at the property line. The Director of
Public Works may modify these standards based on anticipated traffic flow and in accordance with sound
traffic engineering practices. To implement the standards contained in the following table, subdivision
plats for new commercial developments shall be required to provide cross-access easements.
(See table on next page)
Chapter 14 - Engineering Design Standards
Page 14 - 5
Colleyville, Texas, Land Development Code
Driveway Curb Radius
35'
35'
35'
35'
20'
20'
.........................................
20'
30'
Driveway Spacing
(centerline)
Minimum Distance
from Driveway to
Intersection (pi to pi)
Arteria I
Local
Minor Coil.
I\t1tlj()rggll.
Arterial
nl
n/a
n/a
................-...........
n/a
n/a
n/a
E. Provision for Joint Approaches - Driveway approaches shall be located entirely within the frontage of the
premises they serve except that joint, or cooperative, driveways with adjoining property holders may be
permitted by the Director of Public Works. When a joint drive approach is proposed by a developer, the
request must be made by all interested parties and/or all property owners involved.
F. Circular Driveway Approaches at Street Intersections - The Director of Public Works may approve a
circular drive on a corner lot where both streets are residentially classified.
G. Anqle of Driveway Approach - The angle of the driveway approach with the curb line shall be ninety (90)
degrees.
H. Sidewalk to be Removed - Where a driveway approach is to be built, any existing sidewalk located within
the proposed driveway location shall be removed and the entire area replaced as a driveway. The drive
approach shall extend to the property line.
I. Driveways Crossinq Bar Ditches
1. Culvert Size - The minimum culvert pipe size shall be 18" diameter. However, an engineered design
that provides for a larger culvert pipe size may be required by the developer where the Director of
Public Works determines that additional drainage capacity may be required. The ends of all culvert
pipes shall be cut at a 6: 1 slope.
2. Radius - Driveways shall be constructed with the return curbs joining the edge of pavement at the
street with a minimum ten-foot (10') radius.
3. Slope - The maximum slope from the edge of driveway to the top of the culvert pipe shall be 6: 1.
The sloped area around the end of the culvert pipe shall be sodded or hydro-mulched to resist
erosion.
4. Cross Slope - The minimum cross slope on the drive shall be 1/8 inch per foot. The minimum
longitudinal slope between the edge of pavement at the street and the valley over the culvert pipe
shall be 1/4 inch per foot.
Chapter 14 - Engineering Design Standards
Page 14 - 6
Colleyville, Texas, Land Development Code
5. Maintenance - Future maintenance of the drive approach and culvert pipe is the responsibility of the
property owner.
6. Grading - During the drive approach installation, all ditch grading upstream and downstream of the
proposed driveway culvert is the responsibility of the property owner.
J. General
1. Driveway Approaches at Pedestrian Crossings - Driveway approaches shall not be located in street
intersections or at established pedestrian crossings.
2. Driveway Approaches at Obstructions - Driveways shall be kept at a minimum of five (5') feet away
from obstructions such as street light posts, fire hydrants, traffic signals, etc.
3. Accumulative Width of Approaches - Driveway approaches shall not occupy more than forty (40%)
percent of the frontage of a lot or tract.
Section 14-137 Fire lane Requirements (2000 IFC Section 503)
A. Plan Approval - Plans for fire lanes shall be submitted to the Fire Marshal Division for review and
approval prior to construction. Repainting of existing markings does not require plan review unless
changes are to be made.
B. Obstructions Prohibited - Fire lanes shall be kept clear and unobstructed at all times. Marking shall be
repainted as necessary to maintain readability.
C. SiQnaqe - Where required by the Fire Marshal, approved signs or other approved notices shall be
provided and maintained to identify fire lanes and prohibit obstructions.
D. Where Required - Fire lanes shall be provided when any portion of the facility or any portion of an
exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as
measured by an approved route around the exterior of the building or facility.
E. Certain Roadwavs Not Considered Access - Heavily traveled public roadways are not considered for fire
apparatus access due to the dangers involved with operating fire apparatus in close proximity to moving
traffic.
F. Access to Serve All BuildinQs - Fire lanes shall be provided to serve all buildings through parking areas to
service entrances, loading areas, trash collection areas, and other areas deemed necessary to be
available to fire and emergency vehicles.
G. Drivewavs Included - Fire lanes shall include driveways leading onto a public street.
H. Fire Lane Width - Fire lanes shall have an unobstructed width of not less than 24 feet and an
unobstructed vertical clearance of not less than 14 feet.
I. Turninq Radius - Fire lanes shall have a minimum inside turning radius of thirty (30) feet and a minimum
outside turning radius of fifty (50) feet.
J. All-weather Surface Required - Fire lanes shall be designed and maintained to support the imposed
loads of fire apparatus and shall be provided with an asphalt or concrete surface so as to provide all-
weather driving capabilities.
K. Construction Specifications - Fire lanes shall be constructed of seven (7) inch concrete with #3 rebar on
eighteen (18) inch centers on chairs over a modified subgrade as per the Geotechnical Soils Report; or
seven (7) inch asphalt over a modified subgrade as per the Geotechnical Soils Report. The construction
shall be capable of supporting a minimum of 65,000 pounds gross vehicle weight.
Chapter 14 - Engineering Design Standards
Page 14 - 7
Colleyville, Texas, Land Development Code
L. Maximum Dead-end Lenqth - Dead end fire lanes in excess of 150 feet in length shall be provided with
an approved area for turning around fire apparatus. Dead end fire lanes more than 150 feet in length but
less than 700 feet in length shall provide one of the following turn-around configurations. Dead end fire
lanes in excess of 700 feet in length shall be submitted to the Fire Marshal for review and approval.
30' R
TYP.
24' -.
..-
---.
..... 24'
100' DIAMETER
CUL-DE-SAC
ACCEPTABLE ALTERNATIVE
TO 120' HAMMERHEAD
-+
24'
:~R\
+ 70'.
...
70'
..
I~I~I
24~
. +24'
120' HAMMERHEAD
ACCEPTABLE ALTERNATIVE
TO 120' HAMMERHEAD
M. Fire Lane Stripinq - Fire lanes shall be marked with a six (6) inch wide continuous bright red stripe on
both sides. Striping shall be on the curb face where curbing is located at the edge of fire lanes. White 4
inch high lettering with a one (1) inch stroke centered on red stripe shall read: NO PARKING - FIRE
LANE. This lettering shall be painted every (15) feet measured from the end of one lettering group to the
beginning of the next group with a one (1) foot space between "No Parking" and "Fire Lane". Red paint
shall not be used for any parking lot marking other than fire lanes. Fire lane markings are subject to the
field inspection of the Fire Marshal.
Section 14-140 Street Improvement Specifications
A. General - Streets shall be constructed or reconstructed using either hot-mixed asphaltic concrete
pavement sections or reinforced portland cement concrete pavement sections that meet or exceed the
minimum specifications of this Land Development Code. The developer requiring street construction shall
provide a geotechnical report, sealed by a Registered Professional Engineer licensed in the State of
Texas, containing recommendations for subgrade thickness and content. The minimum subgrade and
pavement thickness shall be in accordance with the specifications contained in this Section.
For the purpose of this Section, a collector street shall be defined as all those collector streets shown on
the Master Thoroughfare Plan and those streets internal to a subdivision which provide connection
between local residential streets and the major collector network and which are designed to
accommodate more than 500 vehicles per day.
B. Hot-Mixed Asphaltic Concrete Pavement Sections
1. Local Streets (including cul-de-sac)
Chapter 14 - Engineering Design Standards
Page 14 - 8
Colleyville, Texas, Land Development Code
a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb
line.
b. Prime (or cure) coat.
c. Five (5") inches Type "A" or "B" hot-mixed asphaltic concrete placed in three (3) lifts. The bottom
lift shall extend to one (1') foot beyond the back of curb line.
d. Two (2") inches Type "D" hot-mixed asphaltic concrete placed in one (1) lift.
2. Collector Streets
a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb
line.
b. Prime (or cure) coat.
c. Six (6") inches Type "A" or "B" hot-mixed asphaltic concrete placed in three (3) lifts. The bottom
lift shall extend to one (1 ') foot beyond the back of curb line.
d. Two (2") inches Type "D" hot-mixed asphaltic concrete placed in one (1) lift.
3. Arterial Streets
a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb
line.
b. Prime (or cure) coat.
c. Eight (8") inches Type "A" or "B" hot-mixed asphaltic concrete placed in four (4) lifts. The bottom
two lifts shall extend to one (1 ') foot beyond the back of curb line.
d. Two (2") inches Type "D" hot-mixed asphaltic concrete placed in one (1) lift.
4. Stabilized Subgrade for Hot-Mixed Asphaltic Concrete Pavements - The basic design of the asphaltic
pavement sections for streets and roads assumes average subgrade conditions which in all cases
shall be stabilized to not less than the thickness shown herein with lime or cement at a minimum rate
of 6% of the necessary volume or that recommended by an approved and acceptable geotechnical
report submitted to the City by a licensed Geotech Engineer. Classification of the subgrade for
evaluating the supporting qualities shall generally apply to the top twelve (12") inch layer of soil
measured down from subgrade surface. Where combinations of conditions indicate special
problems, such as springs or seepage, drastic material changes from point to point, etc., that reduce
the existing subgrade below average, appropriate remedies designed by a Registered Professional
Engineer based upon actual onsite observations and tests shall be included to correct the particular
condition involved. In all cases, the requirements set forth in this criteria are minimum and the City
reserves the right to require further additional testing (such as California Bearing Ratio), precautions
or treatments consistent with sound engineering practice when necessary to provide for other
conditions not specifically covered by this criteria. Compaction of stabilized subgrade shall be 95%
standard proctor density.
C. Reinforced Portland Cement Concrete Pavement Sections
1. Local Streets (including cul-de-sac)
a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line.
b. Prime (or cure) coat.
c. Six (6") inch thick portland cement concrete, reinforced with #3 reinforcing bars having a spacing
of eighteen (18") inches center to center both ways.
2. Collector Streets
a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line.
b. Prime (or cure) coat.
c. Seven (7") inch thick portland cement concrete, reinforced with #4 reinforcing bars having a
spacing of eighteen (18") inches center to center both ways.
3. Arterial Streets
Chapter 14 - Engineering Design Standards
Page 14 - 9
Colleyville, Texas, Land Development Code
a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line.
b. Prime (or cure) coat.
c. Eight (8") inch thick portland cement concrete, reinforced with #4 reinforcing bars having a
spacing of eighteen (18") inches center to center both ways.
4. Basic Requirements For All Reinforced Concrete Pavement - The basic design of reinforced concrete
pavement sections for streets and roads assumes poor subgrade conditions which shall be stabilized
with lime or cement at a minimum rate of 6% of the necessary volume or that recommended by an
approved and acceptable geotechnical report submitted to the City by a licensed Geotech Engineer.
In all cases, the requirements set forth in this criteria are minimum and the City reserves the right to
require further additional testing (such as California Bearing Ratio), precautions or treatments, when
necessary, consistent with sound engineering practice to provide for other conditions not specifically
covered by this criteria.
5. Concrete for Pavement - Concrete for pavements shall be Class "A" and consist of five (5) sacks
(minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural
strength of five hundred pounds per square inch (500 PSI) and a twenty-eight (28) day compressive
strength of three thousand five hundred pounds per square inch (3,500 PSI). Composition and
placement of reinforced concrete pavements shall be in accordance with the applicable requirements
of Item 360 of the Texas State Department of Transportation Standard Specifications. Coarse
aggregate shall be either number 2 or 3. Cement for the mixture shall be Type I portland cement. All
hand pours are to be six (6) sacks minimum of portland cement for each cubic yard of concrete mix
with a compressive strength of three thousand five hundred pounds per square inch (3,500 PSI).
D. Curb and Gutter Specifications
All streets shall be provided with reinforced portland cement concrete curbs and gutters in accordance
with the following specifications.
1. Curbs and gutters
a. Curb rolls shall be six (6") inches wide and not less than six (6") inches high nor more than seven
(7") inches high.
b. Curb and gutter bases shall not be less than twenty-four (24") inches wide and provide a
minimum gutter width of eighteen (18") inches (see detail P-4A and P-4B).
c. Gutter depths for hot-mixed asphaltic concrete pavement shall be five (5") inches for local streets
and six (6") inches for collector and arterial streets. Gutter depths for reinforced portland cement
concrete pavement shall be the same as the pavement thickness.
2. Reinforcement Steel - Reinforcement shall be provided by three (3) number three (#3) steel
reinforcing bars by placing one (1) bar in the curb roll and two (2) bars in the curb and gutter base.
This reinforcement is in addition to reinforcement in portland cement concrete pavements.
3. Concrete Classification - Concrete for curbs and gutters shall be Class "A" and consist of five (5)
sacks (minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day
flexural strength of five hundred pounds per square inch (500 PSI) and a twenty-eight (28) day
compressive strength of three thousand five hundred pounds per square inch (3,500 PSI).
4. Installation Procedure - Curb and gutter for hot-mixed asphaltic concrete pavements shall be placed
on the first two (2") inch lift of asphaltic paving. For reinforced portland cement concrete pavements,
the curb and gutter base shall be placed monolithically with the pavement. The curb roll shall be
placed monolithically with the pavement or added separately. Curb rolls added separately shall be
provided with number three (#3) reinforcing bar stirrups spaced twenty-four (24") inches center to
center which extend to within three (3") inches of the bottom of the pavement.
5. Driveway Cuts - All driveway entrances constructed in existing curb and gutters shall be saw-cut at
the curb return on both sides of the driveway and eighteen (18") inches into the street. After work is
Chapter 14 - Engineering Design Standards
Page 14 - 10
Colleyville, Texas, Land Development Code
completed, the street sidewalk shall be repaired and it shall be the responsibility of the party installing
the driveway.
F. Street Drainaqe - The following drainage conditions shall be observed:
1. All roads shall be a crowned or roof top section so as to provide proper drainage.
2. All plats shall depict the flow of drainage with arrows sufficient to show predicted path.
3. An explanation and depiction shall be attached to show outflow and inflow availability on high flow
areas. Adjoining property where inflow originates or outflow exists must be attached to insure
compliance with drainage or excessive run-off factors.
4. No plat shall be considered for approval unless accompanied by a complete set of construction
drawings that show the drainage areas and flow calculations.
5. The contractor/developer will assume all responsibility to disperse excess run-off so as not to exceed
previous disbursements to the satisfaction of the city.
G. Street Construction
1. The street portion of the plat must be approved by the Planning and Zoning Commission or the
Approving Body, Fire Chief, Police Chief and Director of Public Works.
2. The street type code must be plainly visible on the plat and marked so that no misunderstanding can
result.
3. A performance bond must be presented to the City Secretary or duly appointed representative for an
amount equal to the contract by the contractor doing the project. A maintenance bond equal to 10%
of the contract price will be in effect for two (2) years after acceptance by the City.
4. No work shall commence without the issuance of an authorization of construction letter.
5. When Perimeter Street Escrows are required the following items shall be included in the fee
calculations.
a. Paving
b. Subgrade stabilization
c. Curb and gutter
d. Sidewalk (or pathways where applicable)
e. Excavation
f. Utility relocation (20% of paving)
g. Storm sewer improvements (20% of paving)
h. Engineering (12% of the total of items a - g)
i. Contingency (15% of the total of items a - h)
H. Streets to be Trenched - When a public street is cut or trenched, the street shall be repaired according to
this paragraph. A three (3) sack per cubic yard concrete mixture shall be filled-in beginning one (1') foot
above the object the street was cut for and continue until one (1') foot from the top of the street or
reaching the plane of the sub-base compacted to 95% Standard Proctor. The base and topping shall be
the minimum required for that type of street.
I. Forfeiture Clause - If in the opinion of the Director of Public Works or his duly appointed representative,
the street project does not comply with the type code applied to the street(s), the performance bond shall
be forfeited to the amount necessary to correct the substandard section if that section(s) is not corrected
by the contractor.
1. All areas in question by the City that cannot be reconciled by the contractor will be examined by an
independent testing firm, agreed upon by both parties, and its findings will prevail.
Chapter 14 - Engineering Design Standards
Page 14 - 11
Colleyville, Texas, Land Development Code
2. The cost of this testing will be borne by the incorrect party.
3. The City of Colleyville reserves the right to make tests or checks at any place or any time there is a
question of ordinance compliance.
4. Any developer or contractor found to willfully and knowingly misrepresent or disregard the regulations
herein stated shall forfeit all rights and permits in the City of Colleyville, Texas, with a majority vote of
the City Council.
J. Texas Department of Transportation Hiqhwav Specifications - All specifications not specifically provided
for elsewhere in this Chapter are referenced to the Texas Department of Transportation Standard
Specifications For Construction of Highways, Streets and Bridges, 1993, AASHTO's A Policy on
Geometric Design of Highways and Streets, and the Transportation Research Board's Highway Capacity
Manual.
1. Item 260 Lime Treated Subgrade - Lime used shall be Type "A" hydrated lime. The placement and
construction of the subgrade shall be done in accordance with the applicable requirements described
in Item 260 of the Texas State Department of Transportation Standard Specifications.
2. Item 270 Cement Treated Subgrade - Cement used shall be Type 1 portland cement. The placement
and construction of cement treated subgrade shall be done in accordance with the applicable
requirements described in Item 270 of the Texas State Department of Transportation Standard
Specifications. An asphaltic membrane of RC-250 asphalt shall be applied as a cure coat. An
alternate method of wet curing is also acceptable.
3. Item 310 Prime Coat - Asphalt material for prime coat shall be EA-HVMS. The placement of prime
coat shall be described in Item 310 of the Texas State Department of Transportation Standard
Specifications. Prime coat shall be placed on all lime treated subgrade at a rate of not less than 0.15
nor more than 0.25 gallons per square yard.
4. Item 340 Hot-Mixed Asphaltic Concrete Pavement - The composition and placement of hot-mixed
asphaltic concrete pavement shall be in accordance with the applicable requirements of Item 340 of
the Texas State Department of Transportation Standard Specifications. The asphalt for paving
mixture shall be AC-20 forming from 4.5 to 6.0 percent of the mixture by weight. The asphalt for use
as a tack coat under Item 340 shall be either RC-250 or EA-HVRS.
K. Concrete Pipe - All concrete pipe used for drainage purpose on City streets shall be reinforced.
L. Lime Treated Subqrade - Lime treatment shall extend ten (10') feet, if feasible, beyond the completed
street when a future street is proposed to be built to assure proper conformity.
Section 14-145 Street Signs and Traffic Control Signs
A. General Requirement - Street name signs and traffic control signs shall be required for all street
intersections. Installation of signs shall be performed by City work crews after payment to the City has
been received from the developer for the installation costs. The Director of Public Works shall provide the
developer with a cost estimate for all street signs associated with a development. The cost estimate shall
include material and labor costs.
1. The Director of Public Works may require the installation of temporary street signs by the developer.
B. Location - All signs shall be located in accordance with the Texas Manual on Uniform Traffic Control
Devices. Street signs shall be furnished and installed by the subdivider for all intersections within or
abutting the subdivision.
C. Standards - All signs shall conform to the standards as set forth in the Texas Manual on Uniform Traffic
Chapter 14 - Engineering Design Standards
Page 14 -12
Colleyville, Texas, Land Development Code
Control Devices. All road identification signs are to have a blue background with white reflective lettering.
D. Installation - The sign pole shall be buried to a minimum depth of two (2') feet and placed in a twelve
(12") inch diameter concrete filled posthole. The pole shall be tall enough to accommodate all applicable
signs. The bottom of all signs shall be located seven (7') feet above the finished grade of the travel
surface.
E. Approval - The developer shall submit a list of signs to be placed and a graphical representation of the
signs for review by Director of Public Works prior to installation.
F. Custom Siqns - The Director of Public Works may approve custom-made street signs and custom-made
sign poles, provided the Director of Public Works has executed a written agreement with a party
responsible for the maintenance and replacement of such signs or sign poles.
Section 14-150 Sidewalk & Pathways Specifications
A. Permit Required - No person shall construct, reconstruct, alter, repair, remove or replace any sidewalk or
pathway on any public property within the City Limits without first obtaining a permit from the building
permit office, unless the sidewalk or pathway is included on the construction plans of an existing
approved permit.
B. Maintenance Bond - No such permit shall be approved until proof of bonding coverage has been
submitted to the City and a two (2) year maintenance bond in the amount of 10% of the total cost of
construction covering the sidewalk or pathway is in full force and effect at the time of the permit approval.
Such bond shall not be valid unless persons doing the work are covered by the bond. Such bond may
cover other work done by the applicant. The Director of Public Works may waive the maintenance bond
requirement for repair to an existing sidewalk or pathway.
C. Inspection Required - All work done in construction, reconstruction, alteration, repair, or removal or
replacement of sidewalks or pathways shall be inspected by the city inspector to assure compliance with
these regulations. When other public improvements are required, final acceptance of all other
improvements shall not be made until sidewalks or pathways are approved.
D. Minimum Sidewalk or Pathway Width - All sidewalks shall be a minimum of four (4') feet in width, except
a sidewalk located within or abutting a collector street, or larger, as shown on the Master Thoroughfare
Plan, which shall not be less than five (5) feet in width. All sidewalks and pathways shall be constructed
in the area between the curb or grade line of the public street and the abutting property line unless the
pathway is situated within a dedicated pathway easement or right-of-way. The edge of the sidewalk or
pathway shall generally be parallel with the curb line and be situated no more than one (1 ') foot from the
abutting property line. The Director of Public Works may approve a plan to alter the location of a sidewalk
to preserve a tree or for aesthetic purposes. One additional foot of width shall be added to a sidewalk
that abuts a street curb. The widths of all sidewalks and pathways shall be in accordance with the
following table, which are further referenced in Chapter 15 - Public Works Construction Details.
...!YP~..."~".....
.m.....!YP~...::.Eln ..... ..
. mmm.!YPE.l':g':mm
.m.!YPE.l::P"m ..
T pe "E"
4.0 ft.
. .... ...........~........... . ......................................
5.0 ft.
. .....................................................
8.0 ft.
..........................................
10.0 ft.
12.5 ft.
E. Construction Materials - Sidewalks shall be constructed of portland cement concrete (minimum thickness
four (4") inches). Pathway system sidewalks shall be a minimum thickness of five (5") inches. Concrete
for sidewalks and pathways shall be Class "A" and consist of five (5) sacks (minimum) of portland cement
for each cubic yard of concrete mix and have a seven (7) day flexural strength of 500 pounds per square
inch (500 PSI) and twenty-eight (28) day compressive strength of 3,000 pounds per square inch (3,000
Chapter 14 - Engineering Design Standards
Page 14 - 13
Colleyville, Texas, Land Development Code
PSI). Reinforcement shall be in accordance with the construction detail contained in Chapter 15 - Public
Works Construction Details. In such cases, reinforcements shall be #3 steel deformed reinforcing bars on
eighteen (18") centers.
F. Architectural Barriers Act - All sidewalk/street intersections shall be constructed so as to provide a ramp
that complies with the Architectural Barriers Act. Barrier free ramps shall be provided for access to the
street. The following specifications shall apply:
1. Ramp to be minimum four (4') feet in width.
2. Ramp to be constructed with Class "A" concrete.
3. Ramp concrete thickness shall be the same as the street (six (6") inch normal residential).
4. #3 bars shall be used for reinforcement (twenty-four (24") inch on centers).
5. Curb return shall match existing curb height of the street and taper to the connecting walk with a 1-
foot radius.
6. Street shall be blocked out (max. twelve (12") inches) and dowels installed.
7. Saw joints shall be made one and a half (1 1/2") inch minimum depth and sealed with silicone joint
sealant material.
8. Subgrade shall be prepared to a minimum depth of six (6") inches.
9. At no time shall the walk running parallel to the street be altered.
10. Surface of walk shall be coarse and ribbed to provide extra traction (see detail P-8).
Where the above specifications do not apply or have jurisdiction, refer to the specifications from the
American Disabilities Act.
Section 14-155 Street lighting
A. General Reauirement - Street lights shall be installed at all intersections, at the end of all cul-de-sac
streets, and at additional locations in accordance with the following table:
Wood or metal
30 feet
B. Spacina - The number of required street lights shall be equal to the total linear footage between street
intersections divided by the required spacing. Fractions of street lights shall be rounded to the next whole
number.
C. Intervals - Street lights shall be placed at approximately equal intervals between intersections and shall
be subject to the approval of the Director of Public Works.
D. Desian - Cobra head lamps shall be provided on standard street lighting fixtures, except that other lamp
types may be permitted where custom lighting is approved by the Director of Public Works.
E. Custom liahtina - The subdivider may elect to provide custom lighting lieu of the required standard street
lighting, subject to the approval of the city engineer.
F. Custom liahtina Maintenance - If a subdivider elects to provide and install custom lighting, a
homeowner's association (or some other such private entity) shall be created which will be perpetually
liable for all costs associated with the maintenance of the lighting fixtures. Where the city is not liable for
the costs of electrical energy from the custom lighting as provided in this subsection, the homeowner's
association shall also be liable for the electrical energy costs of the custom lighting.
Chapter 14 - Engineering Design Standards
Page 14 - 14
Colleyville, Texas, Land Development Code
Section 14~160 Water System Improvements
A. General - This section pertains to general design requirements for water distribution system construction
in the City of Colleyville. All water lines shall be sized and designed in accordance with the City of
Colleyville Water Distribution System Master Plan or as determined by the Director of Public Works. In
the absence of specific standards, all water supply, distribution, pumping, and storage improvements
shall be designed in accordance with the most current standards of the American Water Works
Association or the Standard Specifications for Public Works Construction of the North Central Texas
Council of Governments or criteria adopted by the Texas Administrative Code, Chapter 290, "Water
Hygiene".
B. Line Sizes & Locations
1. Standard water line sizes are, S inch, 10 inch, 12 inch, 16 inch, 20 inch, and 24 inch diameter. Other
sizes may be approved by the Director of Public Works.
2. All water lines shall be looped. Dead end lines shall not exceed 600 feet, unless approved by the
Director of Public Works. No services shall be allowed on a dead end line.
3. Water lines shall be located within the parkway. Along State Highways, water lines are required on
both sides of the roadway. New water lines crossing existing streets shall be placed by boring. A
casing shall be required under major and minor collector roadways, arterial roadways and Highway
26 (Colleyville Blvd.). Open cut excavation will not be allowed to cross existing streets, unless
approved by the Director of Public Works.
4. Easements for water line construction shall meet the following requirements:
a. The easement width shall be a minimum of 15 feet.
b. In areas where multiple easements exist the easement may need to be wider as specified by the
City.
5. All piping with mechanical couplings, push-on, or similar joints subject to internal pressure shall be
designed with blocking, anchors, and restraining harnesses to preclude separation of joints.
6. Water lines for multi-family, commercial and industrial fire protection lines shall be dedicated to the
public, unless the system is isolated from the public system by a detector check. All water lines shall
be a minimum of eight (S") inches in diameter and looped when possible. Dead end lines shall not
exceed 50 feet on multi-family, commercial, or industrial sites. All public water lines located on
private property shall be centered in a 15-foot minimum easement. Larger easements may be
required by the Director of Public Works to provide adequate space for maintenance. Water lines
shall not be located under paved surfaces where possible.
C. Line and Fittinq Materials - All water lines and fittings shall be new materials and comply with the
following:
1. Water Lines - All water lines shall be Polyvinyl Chloride (PVC) material and be designed,
manufactured, and tested in accordance with the applicable requirements of AWWA C-900 (eight (S")
inch through twelve (12") inch water pipe) AWWA C-905 (sixteen (16") inches and larger water pipe),
and AWWA M-23.
2. Other Pipe Material - All other materials must be submitted for approval by the Director of Public
Works. Ductile Iron pipe is an acceptable substitution.
a. All PVC water pipe shall be blue in color.
b. Eight (S") inch through twelve (12") inch water pipe shall be pressure class 150, DR 1S. Pressure
class 200, DR 14 pipe may be required by the Director of Public Works in areas of high
distribution system pressure, under roadways or other unusual circumstances.
3. Fittings - All fittings shall be ductile iron in accordance with AWWA C110 or AWWA C153.
Chapter 14 - Engineering Design Standards
Page 14 - 15
Colleyville, Texas, Land Development Code
a. Fittings: ANSI/AWWA C111/A21.11, except gaskets shall be neoprene or other synthetic rubber
and factory installed. Natural rubber will not be acceptable.
b. All buried metal shall be wrapped in polyethylene Tube Wrap: ANSI/AWWA C1 05/A21.5.
c. All waterline pipe and fittings shall be new materials and produced in the USA.
D. Installation - All installations shall conform to the latest NCTCOG, TCEQ and AWWA Specifications, as
amended by these standards.
1. All eight (8") inch and ten (10") inch pipe shall be installed with a minimum of forty-eight (48") inches
of cover over top of pipe, and pipe twelve (12") inches and larger shall be installed with a minimum of
sixty (60") inches of cover over top of pipe.
2. The amount of trench excavation shall not exceed two hundred (200') feet from the end of the pipe
laying operations, and no more than three hundred (300') feet of total open trench will be allowed. At
the end of each work day, all trench excavation shall be backfilled and compacted to the end of the
pipe laying operation. Barricades and lights will be required around any open trench or equipment
and cover plates are required in traffic areas.
3. All connections to existing water mains shall be made under pressure unless dry connections will not
cause any loss of service. Under special conditions connections that cause an interruption of service
may be performed with approval of the Director of Public Works.
4. Coated tracer tape or wire shall be installed in the embedment material twelve (12") inches above the
PVC pipe with the tracer wire terminating in in-line gate valve boxes accessible by City Staff.
5. Density tests shall be taken at a minimum of everyone hundred (100') feet for every lift. A maximum
thickness of twelve (12") inches per loose lift is required for all trench backfill. The compaction of
backfill shall meet or exceed 95% Standard Proctor density. A geotechnical report should be
submitted for all trenches. The density reports shall be submitted daily to the City Inspector. The City
has the right to require additional tests if they are deemed necessary.
6. All density reports and bacteria test reports shall be completed, delivered to the Director of Public
Works and Inspector, and approved before paving is allowed to begin.
7. PVC water pipe and appurtenances shall be installed as specified in AWWA M-23 and in accordance
with the pipe manufacturer's recommendations.
8. Fittings shall be installed in accordance with AWWA C-600.
a. All mechanical joint bends, tees, and reducers which require blocking shall be additionally
restrained with EBAA megalug retainer gland or approved equal.
b. All fittings must be polyethylene wrapped.
E. Fire Hvdrants
1. Hydrant Location and Spacing - Fire hydrants shall be provided along fire apparatus access roads
and adjacent public roads. (0-00-126112/19/00)
a. The minimum number of fire hydrants available to a building shall not be less than that listed in
Appendix B of the 2000 International Fire Code, as amended.
b. The number of fire hydrants available to a complex or subdivision shall not be less than that
determined by the spacing requirements in the following table, when applied to fire apparatus
access roads and perimeter public streets from which fire operations could be conducted.
Chapter 14 - Engineering Design Standards
Page 14 -16
Colleyville, Texas, Land Development Code
1 750 or less .m..m...........m. ..
......?..Q9.Q:::.?.!.?.?.9..................
? ,?9.9.m m
m},QQQmm
m..~,?9.Q.=.~.!Q9.9......
4,500 - 5,000
.mm~,~()Q::m . m;m
m..t?,Q9.9.m
~,?QQ:::?!QQQ..... .m,m ..
7,500 or more
1
2
3
3
, ,............................
4
5
6
6
7
.............................................
8 or more
....".,.....................,.............
.....................................
. ...j........... ...
500
450
450
400
350
300
300
250
250
.......................................... .
200
.................~...
250
225
225
....................................
225
.mm216
........................................ .............._..........H."............
180
180
150
150
120
2. Materials - Fire hydrants shall be manufactured in accordance with AWWA C-502, Dry-Barrel Fire
Hydrants. Hydrants shall be manufactured such that all maintenance and adjustments can be
performed without excavation and such that hydrants may be faced in any direction in relation to
base.
3. Installation depth - The standard fire hydrant bury length from ground to bottom of the connecting
pipe shall be three (3') feet six (6') inches. The hydrant shall be of a design that will permit extensions
without disturbing the bottom section of the hydrant.
4. Gate valve - A gate valve shall be installed with each fire hydrant.
5. Manufacturers - Approved fire hydrants manufacturers are as follows:
a. Mueller Centerion A-423
b. Watrous Pacer - 100
c. Clow
6. Locations - Fire hydrants are to be located a minimum of three (3') feet and a maximum of six (6')
feet behind the back of curb.
F. Valves - Valves of approved design shall be installed at the intersections of all water mains so as to
provide for proper maintenance and operation of the system and to provide a means of shutting off the
supply to portions of the system for repairs.
1. Valve Spacing - Valves shall be spaced such that only one fire hydrant is out of service at any
one time. Three (3) valves shall be used on a four-way water line intersection and a minimum of
two (2) valves shall be used on a three-way intersection.
2. Valve Types - Resilient seated gate valves shall be used for six (6") inch through twelve (12")
inch water lines. Butterfly valves shall be allowed for twelve (12") inches and larger water lines
when approved by the Director of Public Works.
3. Valve Materials
a. Resilient Seated Gate Valves
(1) Resilient seated gate valves six (6") inches through sixteen (16") inches shall meet or
exceed the latest revisions of AWWA C509 and shall meet or exceed the requirements of
these standards.
(2) Resilient seated gate valves for buried service shall be furnished with a square two (2")
inch operating nut. The valve box shall be Tyler Pipe 6850 series or approved equal.
The valve box lid shall be painted safety blue. The paint shall be Glidden or approved
equal.
(3) All valves must open left and close right.
Chapter 14 - Engineering Design Standards
Page 14 - 17
Colleyville, Texas, Land Development Code
b. Butterfly Valves - Butterfly valves shall meet or exceed the latest revision of AWWA Standard
C504 for Class 150B butterfly valves and shall meet or exceed the requirements of this
specification. All valve components shall conform to Underwriters Laboratories classification
in accordance with ANSIINSF Standard 61.
4. Valve Installation
a. Valves shall be furnished with extensions, such that the working nut is a maximum of thirty-
six (36") inches below grade.
b. Adjustable valve boxes shall be furnished and set on each valve in accordance with these
standards. Valves that are deeper than forty-eight (4S") inches, AWWA C900 PVC pipe shall
be used for stacks, as long as the adjustable valve box is used at the top.
c. After the final clean-up and alignment has been complete, the contractor shall cast in place a
concrete block, twenty-four (24") inches by twenty-four (24") inches around all valve box tops
at the finish grade. See detail W-3.
d. Valves located within a right-of-way shall be indicated on the face of the curb, or where curbs
do not exist, on a conspicuous location adjacent to the valve location. Markings are to be the
stamping of a four (4") inch high letter "V" with a three-eighths (3/S") inch stroke with the point
of the "V" pointing towards the valve location.
e. Valve markers shall be provided in rural areas.
5. Valve Manufacturers
a. Approved manufacturers of six (6") inch through twelve (12") inch resilient seated gate valves
are as follows:
(1) Mueller, Clow and Waterous
b. Approved manufacturers of sixteen (16") inches resilient seated gate valves are as follows:
(1) Mueller
c. Approved manufacturers of sixteen (16") inch and larger butterfly valves are as follows:
(1) Mueller and Clow
G. Air Release and Flushinq Valves - Adequate air relief, and flushing valves shall be provided for flushing,
disinfecting, daily operation requirements, and repairs when required by the Director of Public Works. Air
release valves shall be required on twelve (12") inches and larger water lines. Water lines shall be
designed so that each section of the water line can be flushed at its lowest and highest points.
1. All dead end lines shall have a fire hydrant installed for flushing purposes. If installation of a fire
hydrant is not possible, a flushing valve is required.
2. A fire hydrant shall be required at high points on water lines smaller than twelve (12") inches for air
relief and flushing.
3. Materials - Air release valves and air/vacuum valves shall meet or exceed the latest revision of
AWWA C512.
H. Tappinq Sleeves - A tapping sleeve and valve shall be used when connecting a new water line to an
existing line. A resilient seated gate valve shall be flanged to the tapping sleeve. The tapping sleeve
shall be a Smith-Blair Spec. 664-665 stainless steel tapping sleeve, or approved equal.
Chapter 14 - Engineering Design Standards
Page 14 - 18
Colleyville, Texas, Land Development Code
I. Water Services
1. Meter Box Locations - The water meter box shall be placed a minimum of two (2') feet behind the
back of curb unless sidewalks are adjacent to the curb, then they are to be set seven (7') feet behind
the back of curb, and the water service shall be a minimum of twelve (12") inches deep, covered with
a meter box in place at grade. If no curb is present, the water service shall be located at the property
line, a minimum of twelve (12") inches deep, covered with a meter box in place at grade. Along
roadways without a curb the water service line shall be constructed at a minimum of twelve (12")
inches below the ditch flow line. All water services crossing beneath streets may be encased in four
(4") inches diameter PVC casing.
2. Meter Size - Meter and service sizes will be determined by the developer prior to requesting service
from Colleyville. The minimum water service size between the water main and the meter shall be one
(1") inch. Water services on undeveloped lots shall be located at the property line and shall be a
minimum of one (1") inch in diameter.
3. Materials
a. Service Saddle - Service saddle shall be double strap bronze with brass body or nylon / epoxy
coated stainless steel double bolt wide straps. Minimum size tap shall be 1 inch diameter.
(1) Approved manufacturers for bronze saddles are Ford, Mueller, Jones or Smith-Blair.
(2) Approved manufacturers for nylon stainless steel saddles are Ford, Mueller, JCM or Romac.
b. Service Line - Service lines shall be one (1") inch minimum diameter, Type K copper as specified
in ASTM B88.
c. Corporation Stop - Corporation stop shall be ball type with a diameter equal to the pipe size with
compression outlet fitting, designed for a minimum working pressure of two hundred pounds per
square inch (200 psi) and threaded counter clockwise. Approved manufacturers are Ford or
Mueller.
d. Angle Stop - Angle stop shall be set with compression inlet fitting and locking wings. Approved
manufacturers are Ford, Mueller or Smith Blair.
e. Meter Boxes - Meter box for one (1") inch meters are to be East Jordan Iron Works brand and
are to be #37-S Plastic Box with Cast Iron Lid. Meter box for one and one-half (1 %") inch and
two (2") inch meters shall be East Jordan Iron Works brand and are to be a 15x27 plastic box with
2 65T dual lids.
4. Installation
a. All water services shall be installed in accordance with these standards.
b. Each individual service location shall be saw cut into the face of the curb with a four (4") inch high
"W" painted blue by the Contractor. If no curb exists a similar mark should be placed in the
pavement near the edge of the roadway.
5. Acceptable Manufacturers for Corporation Stops, Curb Stops, and Service Saddles
a. Ford
b. Mueller
c. Smith-Blair
J. Flushinq Valves
1. Corporation stop shall be two (2") inch ball type with compression outlet fitting, designed for a
minimum working pressure of two hundred pounds per square inch (200").
2. Two (2") inch curb stop shall be ball type with compression inlet fitting with tee head shut off.
Chapter 14 - Engineering Design Standards
Page 14 -19
Colleyville, Texas, Land Development Code
3. Pipe shall be two (2") inches diameter, Type K copper as specified in ASTM BSS.
4. All flushing valves shall be installed within a twenty-four (24") inch round metal meter box.
K. Water Line Borinqs - Casings shall be required under collectors and thoroughfares, highway crossings,
and railroad crossings. Casings may also be required where deemed necessary by the Director of Public
Works. Minimum casing thickness shall be a quarter (1/4") inch. The construction bore pit shall be
located a minimum distance of four (4') feet behind the back of curb or edge of pavement where no curb
is present.
1. Casing Design - The design engineer shall design the water line pipe casing for the following loading
conditions and applicable combinations thereof:
a. Cooper's E-SO Railway loading or AASHTO HS20 loading as applicable.
b. Earth loading with the height of fill above the casing as shown on the plans.
c. Loads applied during jacking, including axial load from jacking.
d. All other applicable loading conditions, including loads applied during transportation and handling.
2. Casing Materials
a. Steel Casing Pipe - Steel casing pipe shall be new (or used if approved by the Director of Public
Works) and suitable for the purpose intended and shall have a minimum yield strength of 35,000
psi. Casing shall meet ASTM A-36, ASTM A-570, ASTM A-135, ASTM A-139, or approved
equal. Pipe shall be coated with coal tar epoxy (15 mils min.) in accordance with AWWA C-210.
Pipe joints shall be welded in accordance with AWWA C-206. After pipe is welded, coating shall
be repaired.
b. Cement Mortar - Cement mortar shall consist of one (1) part cement to two (2) parts clean sand
with sufficient water to make a thick, workable mix.
c. Pressure Grout Mix - Grout shall be comprised of one (1) cubic foot of cement and three and a
half (3.5) cubic feet of clean fine sand with sufficient water added to provide a free flowing thick
slurry. If desired to maintain solids in the mixture in suspension, one cubic foot of commercial
grade bentonite may be added to each twelve (12) to fifteen (15) cubic feet of the slurry.
d. Casing Insulators (Spacers) - Use casing insulators for any type of carrier pipe. Insulators shall
be high density polyethylene. Insulators shall fit snug over the carrier pipe and position the
carrier pipe approximately in the center of the casing pipe to provide adequate clearance between
the carrier pipe bell and the casing pipe. Insulators shall be manufactured by "Recon" and be
Racci Type or approved equal.
3. Casing Installation
a. Excavation and Backfill of Access Pits
(1) Do not allow excavation over the limits of the bore or tunnel as specified. Trench walls of
access pits adjacent to the bore or tunnel face shall be truly vertical. Shore the trench walls
as necessary to protect workmen, the public, structures, roadways, and other improvements.
(2) Excavations within the right-of-way and not under surfacing shall be backfilled and
consolidated by mechanical methods as specified in these standards for compaction of
trenches under roadways. Surplus material shall be removed from the right-of-way and the
excavation finished to original grades. Backfill pits immediately after the installation of the
carrier pipe is completed. If carrier pipe is not installed immediately after casing pipe
installation, the City may require the access pits be temporarily backfilled until installation of
carrier pipe.
(3) Where seeding or sodding is disturbed by excavation or backfilling operations, such areas
shall be restored to the existing or better conditions.
Chapter 14 - Engineering Design Standards
Page 14 - 20
Co/leyvi/le, Texas, Land Development Code
Section 14-165 Wastewater System Improvements
A. General - This section pertains to general design requirements for wastewater collection system
construction in the City of Colleyville. All sewer lines shall be sized and designed in accordance with the
City of Colleyville Waste Water System Master Plan or as determined by the Director of Public Works. In
the absence of or in conflict with a specific standard contained in this Chapter, all collection, treatment,
and disposal systems shall be designed in accordance with the most current criteria adopted by the
Texas Administrative Code, Chapter 317, "Design Criteria for Sewerage Systems", NCTCOG, TCEQ and
ASTM.
B. Sewer Line Sizes and Desiqn
1. Standard sewer line sizes are six (6") inches, eight (S") inches, twelve (12") inches, fifteen (15")
inches, and eighteen (1S") inches in diameter. Other sizes may be approved by the Director of Public
Works.
2. Sewer lines shall be constructed at a minimum depth of four (4') feet and be located within the
parkway or an approved utility easement. A sewer line is required to be constructed on both sides of
a State Highway.
3. Easements for sewer line construction shall meet the following requirements:
a. The easement width shall be a minimum of fifteen (15') feet. Greater easement width may be
required for deep lines.
b. If the sewer line is less than twelve (12') feet deep, the outside diameter of the sewer line shall be
located a minimum distance of six (6') feet from the edge of the easement, and if other utilities are
located in the same easement, the outside diameter of the sewer line shall be located a minimum
distance of three (3') feet from the outside diameter of the other utilities.
c. If the sewer line is greater than twelve (12') feet deep, the outside diameter of the sewer line shall
be located a minimum distance of nine (9') feet from the edge of the easement, and if other
utilities are located in the same easement, the outside diameter of the sewer line shall be located
a minimum distance of six (6') feet from the outside diameter of the other utilities.
d. Proper separation of utilities must be maintained per TCEQ regulations.
4. All sewers shall be designed with consideration for serving the full drainage area subject to collection
by the sewer in question; the drainage area may be modified with the concurrence of the Director of
Public Works because of the projected rate of development or the financial feasibility of the proposed
extension.
5. Sewers should be designed with straight alignment whenever possible. When horizontal curvatures
must be used, radial pipe must be used in accordance with the pipe manufacturer's
recommendations. No joint deflection is allowed without the approval of the Director of Public Works.
6. All sewers shall be designed with hydraulic slopes sufficient to give mean velocities, when flowing full
or half full, of no less than two (2') feet per second.
7. When a one hundred fifty pounds per square inch (150 psi) rated sewer line is required due to its
proximity to a water line, the one hundred fifty pounds per square inch (150 psi) rated pipe shall
terminate at a manhole on each end. The pipe shall be extended to the interior wall of the manhole.
No external boot connection will be allowed.
C. Sewer Line Materials - All sewer lines and fittings shall be new materials and comply with the following:
1. All sanitary sewer pipes shall be Polyvinyl Chloride (PVC) pipe type SDR-35 for sewer lines
constructed less than fifteen (15') feet deep. SDR-26 shall be provided where sewer lines exceed
Chapter 14 - Engineering Design Standards
Page 14 - 21
Colleyville, Texas, Land Development Code
fifteen (15') feet. PVC pipe will not be allowed for depths greater than twenty four (24') feet unless
approved by Director of Public Works.
2. All PVC sanitary sewer pipe shall be green in color. Developer to provide a manufacturers statement
for pipe color other than green.
3. PVC sewer pipe and fittings shall conform to the current ASTM Designation D 3034 for four (4")
inches through fifteen (15") inches and ASTM Designation F 679 for greater than fifteen (15") inches.
D. Sewer Line Installations
1. General
a. All installations shall conform to ASTM Designation D2321, and the latest NCTCOG
Specifications as amended by these standards.
b. Sewer lines shall not be installed within nine (9') feet horizontally of any water main or fire
hydrant. Where this is not possible, separation shall be in accordance with TCEQ standards.
c. Construction shall begin at the downstream end of project and continue upstream with the bell
facing upstream. No upstream piping shall be installed before downstream piping unless
approved by the Director of Public Works.
2. Excavation and Backfill
a. Filter fabric shall be installed separating the backfill material from the rock embedment no more
than twelve (12") inches above the top of the pipe.
b. The amount of trench excavation shall not exceed two hundred (200') feet from the end of the
pipe laying operations, and no more than three hundred (300') feet of total open trench will be
allowed. At the end of each workday, all trench excavation shall be backfilled to the end of the
pipe laying operation. Barricades and lights will be required around any open trench left
overnight.
c. Density tests shall be taken every one hundred (100') feet for every lift. A maximum
thickness of twelve (12") inches per loose lift is required for all trench backfill. A geotechnical
report should be submitted for all trenches. The compaction of backfill shall meet or exceed 95%
Standard Proctor density. The density reports shall be submitted daily to the City Inspector. The
City has the right to require additional tests if they are deemed necessary.
d. A City inspector will be on site at all times when testing is being performed. The City Inspector
shall be present during the placement of trench backfill lifts.
e. All density reports shall be completed, delivered to the Director of Public Works and Inspector,
and approved before paving is allowed to begin.
3. Inspection and Testing
All sanitary sewer lines shall be inspected using standard television inspection methods prior to
acceptance by the City. The developer is responsible for television testing.
a. The Contractor is responsible for cleaning the sewer pipe. If the inspection shows debris or
evidence that the line has not been properly cleaned, the review will cease and the tape will be
returned to the Contractor.
b. A City representative will be present during the television inspection and all other testing
procedures, unless otherwise authorized in writing.
c. The televised inspection shall commence only after the line has passed both air and mandrel test.
d. The sanitary sewer system must pass all air, mandrel and television tests prior to paving.
e. The air and mandrel test must meet the required specifications set forth by the NCTCOG and
TCEQ.
f. All sanitary sewer mains must be flushed clean with water just prior to televised inspection. All
debris must be captured and prevented from blocking the system. Water is to be provided at the
Contractor's expense. A City representative is to be present during the flushing of the main.
g. All television equipment used shall have a minimum of two hundred twenty (220) lines of
horizontal resolution. The picture shall be in color.
Chapter 14 - Engineering Design Standards
Page 14 - 22
Colleyville, Texas, Land Development Code
h. All video information on tape must have good picture quality.
i. As a title heading on the tape and during the televising, the operator must note the following:
(1) project name and Contractor name.
(2) name of the company and the operator performing the video inspection.
(3) line size and material, joint type and length.
(4) line segment to be televised including beginning and ending station numbers.
(5) page of plans used and year plans were stamped.
(6) date and time of inspection.
(7) A footage counter must be displayed on the tape during the filming.
(S) Show the above title block before and after each line segment. Show the title block at one
hundred (100') foot intervals while filming the line segment.
(9) All defects should be shown on film for a minimum of ten (10) seconds before proceeding
with the televising.
j. The Contractor shall supply a log sheet used in conjunction with the video tape for written
documentation. All written information gathered must be legible and clearly understandable.
(1) Note the project name, Contractor name and contract number.
(2) Note the name of the company and the operator performing the video inspection.
(3) Note pipe size and material, joint type and length between joints.
(4) Note the VCR tape footage counter, start to end.
(5) Note line segment to be televised, station numbers from and station numbers to length of line
segment as indicated on plans.
(6) Note page of plans used and year plans were stamped.
(7) Note date and time of inspection.
(S) Indicate by sketch the line segment to be televised in relation to surrounding road
intersections and street addresses. Identify manhole station numbers. Show direction of flow
with arrows and direction the camera is going. Indicate direction of north on the sketch.
(9) Note the water depth at the beginning, every fifty (50') foot station, every change in grade,
and at the end of the line segment.
(1 O)ldentify the clock location, direction, size and type of laterals entering main. Indicate laterals
as saddles, punched, or glued fittings.
(11) Indicate final footage televised at end of the log sheet.
k. One tape per visual televised inspection project shall be furnished to the Project Inspector.
I. Tapes must be VHS format, one (1") inch wide T-120, high quality tape. Tapes are to be recorded
on SP (2 hours) play.
m. All tapes and run sheets shall be submitted to the City. All tapes and log sheets shall become the
property of the City.
4. Criteria for Repair
The Contractor shall make repairs if the inspection reveals any deficiency in the sewer line. If repairs
are required, another television inspection shall be made after the repairs are complete on a new tape
from manhole to manhole at the Contractor's expense. Any water discovered with a depth of more
than one-quarter (1/4") inch will require removal and replacement of the portion of the line not within
specification. Repairs shall be made to the satisfaction of the Director of Public Works.
E. Manholes
1. Manholes shall be located at all intersections of sewer lines and at intermediate spacing along the
line. Generally the maximum spacing should not exceed five hundred (500') feet. Manholes should
be located at all changes in grade and at the ends of all sewer lines that will be extended.
2. A manhole is required at the junction of sewer lines with different inside pipe diameters.
3. A drop of at least one tenth of a foot (0.1') is required through the manhole when a change in flow
direction occurs.
Chapter 14 - Engineering Design Standards
Page 14 - 23
Colleyville, Texas, Land Development Code
4. A drop manhole is required when the flow line in is two (2') feet or more greater than the flow line out.
5. Minimum manhole inside diameter is four (4') feet.
6. Drop-connection manholes shall have a minimum inside diameter of four (4') feet, with an exterior
drop.
7. Minimum cast-in-place manholes must be installed to the North Central Texas COG standards.
8. Minimum pre-cast wall thickness is five (5") inches.
9. A manhole is required where a sanitary sewer line enters and exits private property.
10. All manholes shall be concrete.
11. Sanitary sewer manhole sizes shall be in accordance with the following table:
...................................
..............,....................
5'
5'
6'
Note: If the proposed design requires the sewer line to be placed at depths greater than
shown above, the design will require approval by the Director of Public Works.
12. Cast-in-place Manholes
a. The manhole foundation shall be poured on undisturbed soil and shall have a minimum thickness
of eight (8") inches.
b. The inlet and outlet pipes shall be poured into the foundation of the manhole. When straight
through flow occurs, the pipe shall be laid continuously through the manhole.
c. The invert shall be shaped and smoothed so that no projections will exist and the invert shall be
self cleaning.
d. When a cast-in-place manhole is used to connect to an existing sewer line the manhole should be
poured, tested and approved before the top of the existing line is cut out.
e. Concrete work shall conform to all requirements of ACI 301, Standard Specification for Structural
Concrete, published by the American Concrete Institute, except as modified herein.
f. Detailing of concrete reinforcement and accessories shall be in accordance with ACI Publication
315.
g. Portland cement shall be Type II, low-alkali and conform to ASTM Designation C-150.
h. The manhole shall not be backfilled within twelve (12) hours after the concrete placement.
Backfill shall be compacted and reports submitted to the City.
i. The face of curb shall be stamped with a three (3") inch "MH" to mark the location of all
manholes. The location of the stamp shall be a line that intersects the center of the manhole
cover and the curb perpendicular to the centerline of the street. For manholes located in
intersections, the curb shall be stamped at the closest location to the manhole. If no curb exist a
similar mark should be placed in the pavement near the edge of the roadway.
13. Precast Manholes
a. Precast manholes shall be constructed in accordance to ASTM Designation C-478.
b. Manhole base shall have a spread footing and be placed on a minimum of twelve (12) inches of
crushed rock.
Chapter 14 - Engineering Design Standards
Page 14 - 24
Colleyville, Texas, Land Development Code
14. Manufacturers - Approved precast manhole manufacturers are as follows:
a. Hydro-conduit
b. Gifford Hill American
F. Manhole Frames and Covers
1. Cover
a. Materials - All manhole covers shall conform to the Standard Specifications for Domestic Grey
Iron Castings, ASTM A-48, Class 30 B.
b. Installation
(1) All manhole covers shall be twenty four (24") inches in diameter.
(2) All manhole covers shall have two (2) integrally cast pick bars.
c. Manufacturers (Traffic rated where necessary)
(1) Bass and Hays
(2) Vulcan
2. Frames
a. Materials - All manhole frames shall conform to the Standard Specifications for Grey Iron
Castings, ASTM A-48, Class 30 B.
b. Installation - All manhole frames shall provide a twenty four (24") inch by one quarter (1/4") inch
opening to assure proper fit of the manhole cover.
c. Manufacturers
(1) Bass and Hays
(2) Vulcan
d. Manholes located within the floodplain are to be sealed cover and frame.
3. Extension Rings
a. Materials - All precast reinforced concrete extension rings shall conform to ASTM C-478.
b. Installation
(1) The number of extension ring sections shall be kept to a minimum (Le. use 1-12 inch
extension ring instead of 2-6 inch extension rings).
(2) A one (1") inch by three and a half (3 1/2") inch bitumastic gasket shall be used to seal the
extension ring at both joints.
4. Rain Pan
a. Materials - Rain pans shall be high density polyethylene plastic.
b. Manufacturers - Knutson or approved equal.
G. Sewer Services
1. No sewer service line (lateral) shall be less than four (4") inches in nominal diameter.
2. Sewer laterals shall be located at the center of the lot and extended to the property line and be a
Chapter 14 - Engineering Design Standards
Page 14 - 25
Colleyville, Texas, Land Development Code
minimum of ten (10') feet downstream of the water service. Services will be identified in the field by a
three (3") inch "S" cut into the curb, on the As-Built Plans and with a stake in the field for location
purposes.
3. Sewer service laterals shall have a minimum of four (4') feet of cover at the property line.
4. A c1eanout shall be located on the service lateral at the time of connection to the home.
5. Materials
a. All lateral sewer service lines shall be gasketed PVC pipe type SDR-35.
b. All PVC sanitary sewer pipe used for lateral services shall be green in color. (ASTM SPEC)
6. Installation - All service laterals shall be installed in accordance with the sanitary sewer embedment
and backfill standards of the City of Colleyville.
7. Video Inspection Required - All sewer service lines that are connected to a section of sewer service
piping located within the right-of-way must have a clean-out installed where the property line abuts
the right-of-way. After the new sewer service line has been connected and the excavated area is
backfilled, the portion of the sewer service line located within the right-of-way including the tap into
the sewer main must be televised. The video tape must be submitted to and approved by the City of
Colleyville Public Works Department.
8. Point of Connection - The point of connection for all sanitary sewer service lines shall be made to an
approved public sewer main line. No sanitary sewer service line shall directly connect to a manhole.
H. Main Line Cleanouts - Cleanouts may be installed on lines that are permanent dead ends. The line may
not exceed two hundred fifty (250') feet. Any line exceeding that length must end with a manhole.
I. Sewer Line Borinqs
1. The design engineer shall design the sewer line pipe casing for the following loading conditions and
applicable combinations thereof.
a. Cooper's E-80 Railway loading or AASHTO HS20 loading as applicable.
b. Earth loading with the height of fill above the casing as shown on the plans.
c. Loads applied during jacking, including axial load from jacking.
d. All other applicable loading conditions, including loads applied during transportation and handling.
2. Materials - Materials must meet jurisdictional requirements in all areas, Railroad, TCEQ, TXDOT, etc.
a. Steel Casing Pipe - Steel casing pipe shall be new (or used if approved by the Director of Public
Works) and suitable for the purpose intended and shall have a minimum yield strength of 35,000
psi. Casing shall meet ASTM A-36, ASTM A-570, ASTM A-135, ASTM A-139, or approved
equal. Pipe shall be coated with coal tar epoxy (15 mils min.) in accordance with AWWA C-210.
Pipe joints shall be welded in accordance with AWWA C-206. After pipe is welded, coating shall
be repaired.
b. Cement Mortar - Cement mortar shall consist of one (1) part cement to two (2) parts clean sand
with sufficient water to make a thick, workable mix.
c. Pressure Grout Mix - Grout shall be comprised of one (1) cubic foot of cement and three and a
half (3.5) cubic feet of clean fine sand with sufficient water added to provide a free flowing thick
slurry. If desired to maintain solids in the mixture in suspension, one (1) cubic foot of commercial
grade bentonite may be added to each twelve (12) to fifteen (15) cubic feet of the slurry.
d. Casing Insulators (Spacers) - Use casing insulators for any type of carrier pipe. Insulators shall
be high density polyethylene. Insulators shall fit snug over the carrier pipe and position the
carrier pipe approximately in the center of the casing pipe to provide adequate clearance between
Chapter 14 - Engineering Design Standards
Page 14 - 26
Colleyville, Texas, Land Development Code
the carrier pipe bell and the casing pipe. Insulators shall be manufactured by "Recon" and be
Racci Type or approved equal.
3. Installation
a. Tolerances
(1) All bores shall be installed at a grade no less that the minimum indicated by TAC, Chapter
317 for the desired pipe size.
(2) All bores shall maintain grade enough to ensure desired clearance distances between
existing utilities and bore.
b. Excavation and Backfill of Access Pits
(1) Bore pits must be a minimum of four (4') feet from the back of curb when located for boring
under roadways.
(2) Do not allow excavation over the limits of the bore or tunnel as specified. Trench walls of
access pits adjacent to the bore or tunnel face shall be truly vertical. Shore the trench walls
as necessary to protect workmen, the public, structures, roadways, and other improvements.
(3) Excavations within the right-of-way and not under surfacing shall be backfilled and
consolidated by mechanical methods as specified in these standards for compaction of
trenches under roadways. Surplus material shall be removed from the right-of-way and the
excavation finished to original grades. Backfill pits immediately after the installation of the
carrier pipe is completed. If carrier pipe is not installed immediately after casing pipe
installation, the right-of-way Owner may require the access pits be temporarily backfilled until
installation of carrier pipe. Plug ends of sleeves to prevent soil migration.
(4) Where seeding or sodding is disturbed by excavation or backfilling operations, such areas
shall be replaced to meet existing or better conditions.
Section 14-170 Drainage and Storm Sewer Improvements
A. General - This section pertains to general design requirements for drainage and storm sewer
construction in the City of Colleyville. All drainage facilities shall be sized and designed in accordance
with the City of Colleyville Drainage Master Plan or as determined by the Director of Public Works.
B. Runoff Calculations - The selection of which method to use for calculating runoff depends upon the size
of the contributing drainage area at the most downstream point of the project. The "Rational Method" is
acceptable for designing projects in which the drainage area is less than one-hundred (100) acres. A unit
hydrograph method is required for projects with larger drainage areas.
1. No matter which method is used to calculate runoff, a developer or builder of residential property
greater than one (1) acre in size, or any property that was platted as a part of an overall tract which
was greater than one (1) acre in size (including churches and schools), shall develop the property so
that the rate of runoff created by the development as it leaves the property does not exceed the rate
of runoff that is currently occurring in the existing conditions. A developer or builder of commercial
property greater than one-half (1/2) acre must follow the above guidelines.
2. Runoff computations shall be based upon fully developed watershed conditions in accordance with
the land use projections in the latest comprehensive land use plan for the City of Colleyville. The
design engineer shall size drainage facilities by disregarding the detention effects of upstream
property and calculating the runoff as if the off-site property was developed without any detention. If
an approved regional detention/retention facility is in operation, the design engineer may size
downstream drainage facilities based on consideration of the detention effects of the regional facility.
C. Drainaoe Areas Less Than one-hundred acres
1. Computation of Storm water Runoff for drainage areas less than one-hundred (100) acres shall be by
the "Rational Method," which is based on the principle that the maximum rate of runoff from a given
Chapter 14 - Engineering Design Standards
Page 14 - 27
Colleyville, Texas, Land Development Code
drainage area for an assumed rainfall intensity occurs when all parts of the area are contributing to
the flow at the point of discharge.
...... ...P~.~.~...~.~~~.!:l...~....1'l9...~.~\I.~I()p~~...I~.~.~......
[?~\I~I()PEl<lP~r.~!:litEl!:lmmmmmm..... m .
.~!1.l9IElI"~'!liIYf3E!!:li<lE!I.l!i~lm ... .
[?l,lpIEl)(m...
... ...........Ml,lI!ipl~.~.C1'!li.l.y.......
Schools
.................................... .
Churches
.........................................................................................................................
. .mNE!i9~b.gr~()l?<l~<:l'!l'!lEl~~.i!3.lm
Office Commercial
...................................................................
Commercial
................................................. .
Industrial
0.60
0.70
0.70
0.70
0.70
0.70
0.85
2. Time of concentration is the longest time, without interruption of flow by detention devices that a drop
of water takes to flow from the farthest point of the drainage area to the point of concentration (i.e. the
point of design). The time of concentration is composed of the inlet time and the flow time in a
conduit or channel to the point of design.
The inlet time shall be 10 minutes for property zoned multiple family, churches, schools, local
business, central business, commercial, or industrial.
An inlet time of 15 minutes shall be used for property zoned for parks, cemeteries, agricultural, and
single family residential.
When designing inlets and laterals, the time of concentration is equal to the inlet time. The design
engineer will compare the above specified inlet times to the actual calculated inlet time by computing
the flow time overland and along the gutter to the first inlet. Manning's Equation shall be used to
determine flow time to the inlet. The design engineer may use the actual calculated or specified inlet
time. In no case shall a longer inlet time be used than 10 minutes for multiple family, commercial,
churches, schools, industrial and business areas and 15 minutes for parks, cemeteries, agricultural,
and single-family areas.
D. Drainaqe Areas of one-hundred (100) acres or More
1. For drainage areas of one-hundred (100) acres or more where the use of the "Rational Method" does
not provide reliable results, the use of a unit hydrograph method shall be made. The use of a unit
hydrograph calculation will be based upon standard and accepted engineering principles subject to
the approval of the Director of Public Works. Acceptable methods include the Soil Conservation
Service (SCS) Technical Release Number 55 or the Corps of Engineers HEC-1 models for drainage
areas one-hundred (100) acres or more.
2. The unit hydrograph method shall be based upon fully developed watershed conditions assuming no
effects from the small on-site detention facilities for maintaining the rate of runoff as if the property
was undeveloped. The detention effects of large regional detention facilities can be taken into
account in unit hydrograph methods.
3. Circumstances that may require the use of a unit hydrograph method include sizing open channels,
reclaiming floodplains, creating lakes, or building other types of drainage-related facilities on major
drainage courses. Design engineers of these types of facilities should be aware that the requirement
of designing for fully developed watershed conditions will mean that they will have to calculate these
Chapter 14 - Engineering Design Standards
Page 14 - 28
Colleyville, Texas, Land Development Code
fully developed flows instead of using the flows calculated in the Federal Emergency Management
Agency's (FEMA) flood insurance studies for Colleyville or Tarrant County or from studies performed
for or approved by the City of Colleyville.
E. Desiqn Storm Frequencies - All developments submitted must provide data for the following design storm
frequencies: 2-Year /5-Year /10-Year /25-Year /50-Year /100-Year.
1. Drainage facilities shall be designed in accordance with the following table:
Closed Storm Sewer Systems ! 5-year with 1 DO-year positive overflow in streets
i such that the depth of flow in the street does not
, exceed the right-of-way or drainage easement
....Cios.edSlormSewerSystems \....{m~~2~iwith.positFveoveffiov:;m
and Inlets at Street Low Point :
g~_~_~9m.__.mm__m
_.gl!ly~r,t~.'l.Il<:l...!=l..r..i.<:l9.~~..............
Concrete-lined Channels
.................................H.H.H.......H.H.........................
Earthen Channels
2. The approved drainage system shall provide for positive overflow at all low points and these areas
must be denoted on the plans as such. The term "positive overflow" means that when the inlets do
not function properly or when the design capacity of the conduit is exceeded, the excess flow can be
conveyed overland along a grassed or paved course. Normally, this would mean along a street or
alley, or shall require the dedications of special drainage easements on private property.
F. Street and Alley Capacity
1. Streets - Streets and storm drains within new developments shall be designed so that storm water
runoff resulting from a design storm of a one-hundred (100) year frequency is contained within the
available right-of-way and/or drainage easement. The capacity of the street and right-of-way and/or
easement and the storm sewer pipe working in combination must be designed for a capacity to safely
contain a storm water from a design storm of one-hundred (100) year frequency.
2. Alleys - The flows created by the one-hundred (100) year storm shall be contained within the
capacity of all paved alleys.
G. Inlet Placement and Capacity - The storm sewer system is to begin at the point where the storm water
from a five (5) year frequency storm reaches curb depth, with the exception of collector streets on which
storm sewer facilities must be designed to prevent one-twelve (12') foot wide lane from ponding and on
major streets on which storm sewer facilities must be designed to prevent one-twelve (12') foot wide lane
in each direction from ponding. At such point where the combined capacity of the street and storm drain
system satisfies the five (5) year street capacity criteria (as previously described) but the one-hundred
(100) year frequency storm runoff can not be contained within the right-of-way additional pick-up points
(inlet capacity) shall be provided along with an increase in storm sewer capacity so that the one-hundred
(100) year frequency storm runoff will be contained within the right-of-way.
1. Inlets shall be placed upstream from an intersection whenever possible. At any intersection, only one
street shall be crossed with surface drainage and this street shall be the lower classified street.
When an alley intersects a street, inlets shall be placed in the alley whenever flow down that alley
would cause the capacity of the intersecting street to be exceeded.
2. The minimum inlet size shall be ten (10') feet. No more than twenty (20') feet of inlet shall be placed
along one gutter at any given location. Minimum sizes of laterals shall be twenty-one (21") inches for
use with ten (10') foot inlets, and twenty-four (24") inch laterals with fourteen (14') foot, twenty (20')
foot inlets, and drop inlets. Where laterals tie into trunk lines, place the laterals on a minimum angle
forty-five (450) degrees and a maximum angle of sixty (600) degrees with the trunk line and connect
them so that the longitudinal centers intersect.
Chapter 14 - Engineering Design Standards
Page 14 - 29
Colleyville, Texas, Land Development Code
3. Manholes are required every three hundred feet (300'). Junction boxes are required at every change
in flow line direction, change in pipe size, and where a convergence of more than two pipes occurs.
Manholes are to be five feet (5') square and can be precast or cast in place.
H. Pipe Desiqn Standards
1. Storm sewer conduit shall be sized to flow full. Manning's Equation shall be used to determine the
conduit size.
2. Design Velocities
a. Minimum - two and a half feet (2.5') per second.
b. Maximum - twelve feet (12') per second.
c. The maximum discharge velocities in the pipe shall also not exceed the permitted velocity of the
receiving channel or conduit at the outfall to prevent erosive conditions. The maximum outfall
velocity of a conduit in partial flow shall be computed for partial depth and shall not exceed the
maximum permissible velocity of the receiving channel unless controlled by an appropriate
energy dissipater (e.g. stilling basins, impact basins, riprap protection).
3. In general, storm water shall be carried in concrete pipe conduit within the right-of-way but other
types of conduit can be used to carry stormwater in areas other than the right-of-way. However, prior
permission to use other conduit materials must be obtained from the Director of Public Works.
4. Hydraulic Gradient (also refer to the Ft. Worth Drainage Manual)
a. Conduits must be sized, and slopes must be set, such that runoff flows smoothly down the
drainage system. To insure this smooth passage, the hydraulic gradient must be at the proper
elevations. The hydraulic grade line shall be established and shown on the plans for all storm
sewer design.
b. The hydraulic grade line shall in no case be closer to the surface of the ground or street than one
foot (1'). The HGL must not exceed the neck into the inlet.
c. Hydraulic gradient calculations shall account for all head losses that may occur in the storm
sewer line. Friction head loss shall be determined by direct application of Manning's Equation.
Minor losses due to turbulence at structures shall be determined using Appendix A of this section.
5. Inspection / Testing
a. The compaction of backfill shall meet or exceed 95% Standard Proctor density.
b. All storm sewer conduits shall be inspected prior to acceptance by the City. All conduit forty-two
inch (42") or less shall be inspected using television inspection. Conduits larger than forty-two
inch (42") may be inspected visually.
c. A City representative shall be present during the television inspection.
d. Televised Inspection Criteria
(1) All television equipment used shall have a minimum of two-hundred-twenty (220) lines of
horizontal resolution. The picture shall be in color.
(2) All video information on tape must have good picture quality.
(3) As a title heading on the tape and during the televising, the operator must:
i. Note the project name and Contractor name.
ii. Note the name of the company and the operator performing the video inspection.
iii. Note line size and material, joint type and length.
Chapter 14 - Engineering Design Standards
Page 14 - 30
ColleyvWe, Texas, Land Development Code
iv. Line segment to be televised including beginning and ending station numbers.
v. Note page of plans used and year plans were stamped.
vi. Note date and time of inspection.
vii. A footage counter must be displayed on the tape during the filming.
viii. Show the above title block before and after each line segment. Show the title block at
one-hundred (100') foot intervals while filming the line segment.
ix. All defects should be shown on film for a minimum of 10 seconds before proceeding with
the televising.
(4) The Contractor shall supply a log sheet used in conjunction with the video tape for written
documentation. All written information gathered must be legible and clearly understandable.
i. Note the project name, Contractor name and contract number.
ii. Note the name of the company and the operator performing the video inspection.
iii. Note pipe size and material, joint type and length between joints.
iv. Note the VCR tape footage counter, start to end.
v. Note line segment to be televised, station numbers from and station numbers to length of
line segment as indicated on plans.
vi. Note page of plans used and year plans were stamped.
vii. Note date and time of inspection.
viii. Indicate by sketch the line segment to be televised in relation to surrounding road
intersections and street addresses. Identify manhole station numbers. Show direction of
flow with arrows and direction the camera is going. Indicate direction of north on the
sketch.
ix. Note the water depth at the beginning, every fifty (50') foot station, every change in
grade, and at the end of the line segment.
x. Identify the clock location, direction, size and type of laterals entering main. Indicate
laterals as saddles, punched, or glued fittings.
xi. Indicate final footage televised at end of the log sheet.
(5) One tape per visual televised inspection project shall be furnished to the Project Inspector.
(6) Tapes must be VHS format, one (1") inch wide T-120, high quality tape. Tapes are to be
recorded on SP (2 hours) play.
(7) All tapes and run sheets shall be submitted to the City. All tapes and log sheets shall
become the property of the City.
I. Culvert Desiqn - Culverts must be designed using standard engineering practices and engineering
judgment. Culverts shall be designed in accordance with the latest edition of the City of Fort Worth
Drainage Manual. If the City of Fort Worth Drainage Manual does not incorporate the necessary
standards please refer to the Texas Department of Transportation (TxDOT) Hydraulic Design Manual.
1. One (1') foot of freeboard is required between the one-hundred (100) year water surface elevation
and the top of curb elevation. Exceptions must be approved in writing by the Director of Public
Works.
2. Culvert hydraulic grade line calculations shall consider both inlet and outlet control.
3. Culverts shall be aligned to provide the minimum resistance to the flow of water during the 10, 50,
100 and 500 year events.
4. The maximum velocity through a culvert shall be fifteen (15') feet per second.
5. Stream stability shall be assessed when determining the number of barrels, height and width and
culvert skew. Potential for scour shall be accounted for in the design.
6. Hydraulic jumps shall not be allowed from face of culvert to ten (10') feet from the culvert, subject to
the approval of the Director of Public Works.
Chapter 14 - Engineering Design Standards
Page 14 - 31
Colleyville, Texas, Land Development Code
J. BridQes - Two (2') feet of freeboard is required between the one-hundred (100) year water surface
elevation and the low chord of the bridge. Exceptions to this requirement must be approved by the
Director of Public Works in writing.
1. The skew of the bridge piers and abutments shall be oriented as close to the normal or flood direction
of flow resulting in an angle of attack as close to zero (0) degrees as possible.
2. Bridge piers shall be aligned to provide the minimum resistance to the flow of water during the 10, 50,
100 and 500 year events.
3. Computer modeling programs used for the hydraulic analysis of bridges shall be HEC-RAS, Version
2.2, or HEC2.
4. Stream stability shall be assessed when designing the abutments and interior bents of the bridge.
Scour shall be accounted for in the design.
5. Where flows are supercritical, erosion control measures shall be used in an area from one-hundred
(100') feet upstream from a bridge to twenty-five (25') feet downstream from a bridge.
K. Channels - Open channels may be used instead of an enclosed system when a pipe greater than an
eighty-four (84") inch diameter (or other shape equivalent to more than thirty-eight and a half (38.5)
square feet) is required to carry the design storm event.
1. Design Criteria:
a. All open channel design must follow the Corp of Engineers Guidelines.
b. Channels may be left in their natural state provided that the channel velocities are six (6.0') feet
per second or less and that one (1') foot of freeboard is available during the design storm event.
c. If the natural channel is to be replaced by an improved channel, the flow from the one-hundred
(100') year design flood must be contained within the improved channel while allowing for one (1')
foot of freeboard.
d. Improved channels shall be trapezoidal shaped and include a lined section if the design velocity
is greater than six feet per second. Lining types such as concrete, rock walls and gabions may
be used upon approval of the Director of Public Works. The maximum velocity allowed in
concrete lined channels is fifteen (15') feet per second.
e. Unless shown to be feasible in a soils report sealed by a licensed professional engineer in the
State of Texas, and approved by the Director of Public Works, improved channels shall have
minimum side slopes of:
(1) 4 feet horizontal to 1 foot vertical for earthen, grassed-lined side slopes.
(2) 2 feet horizontal to 1 foot vertical for concrete-lined side slopes.
f. Where practicable, all unpaved channels should have sufficient grade to avoid ponding. A
minimum slope of 1.00% is required for earthen channels and swales, except those used as part
of a wetlands area. In areas where 1.00% cannot be obtained a pilot channel approved by the
City may be used. All lined channels are to have a minimum slope of 0.50% and earthen
channels a minimum slope of 1.00%.
g. The developer or owner shall use low maintenance vegetation for vegetative cover, as approved
by the Director of Public Works prior to planting. The selection of materials shall comply with the
current ground cover listing for North Central Texas furnished through the Texas Agricultural
Extension Service.
2. Manning's Equation can be used to design channels and determine water surface elevations and
Chapter 14 - Engineering Design Standards
Page 14 - 32
Colleyville, Texas, Land Development Code
velocities when backwater effects are negligible, subject to approval by the Director of Public Works.
Channels where backwater effects occur must be designed using models accepted by FEMA.
3. All channel sections must consider and account for channel stabilization in their design. This
requirement pertains to all sections whether they are left in their natural condition or are modified in
any manner. The design of all drainage channels and swales shall assure adequate capacity and
minimum maintenance to overcome the result of erosion, silting, sloughing of bends or similar
occurrences.
4. When performing hydraulic analyses for channel or drainageway design, the one-hundred year (100)
year starting water surface shall be based on the following:
a. Known water surface elevations should be used where possible. Known elevations are available
for some creeks and channels from previous studies approved by the City.
b. When known water surface elevations are not available the slope-area method or a rating curve
may be used.
(1) A rating curve approximates the starting water surface elevation for a given flow by using the
relationship between known flows and water surface elevations for the creek. This is an
excellent method for determining starting conditions if good data is available to develop the
rating curve.
(2) The slope-area method approximates the starting water surface elevation by calculating the
normal depth for the channel. To calculate normal depth the slope of energy gradient for the
channel is required. The energy slope can be approximated using the average slope of the
channel or the average slope of the water surface.
5. The design of the channel lining shall take into account the super-elevation of the water surface
around curves and other changes in direction. In general a radius that is three (3) times the top width
of the water surface during the design storm event is recommended for channel bends.
6. A chain link fence six (6') feet in height, or other improvements as approved on a case by case basis
by the Director of Public Works, shall be constructed on each side of the lined channel.
7. Gabion or other forms of channel lining may be used in lieu of reinforced concrete lining with the
approval of the Director of Public Works.
L. Detention Desiqn - Runoff rates for all land uses shall be limited to the rates that would be produced from
single family residential areas. This requirement also applies to the development of sites as churches,
schools, and other institutional uses. Detention/retention facilities shall be designed for the fully
developed one-hundred (100) year design flood according to the following criteria:
1. The minimum amount of storage volume of the detention basin shall be that volume required to
reduce runoff rate during the one-hundred (100) year event to the undeveloped rate. The outflow
structure shall be sized to reduce the 2, 5, 10, 25, 50, and 100 year discharges to the undeveloped
rate. Dedicated detention/retention basins shall also include an additional one (1) foot of freeboard
and two (2) feet of sediment storage. The volume of runoff storage for drainage areas greater than
one-hundred (100) acres shall be computed using unit hydrograph procedures. Acceptable unit
hydrograph procedures are provided in Section 14-170.D.1 of this document.
For drainage areas less than one-hundred (100) acres, the above methods are recommended;
however, an approximate routing method based on the modified rational method is allowable.
2. All detention facilities designed shall consider the timing of the flood peak in the main channel into
which the detention facility drains. Delaying the peak from a site in lower portions of a watershed
may result in a higher peak on the main channel. The Director of Public Works may require that
upstream and downstream ponds be included in the detention design model.
3. A detention facility shall have enough gradient to ensure positive drainage to the outlet structures so
Chapter 14 - Engineering Design Standards
Page 14 - 33
Colleyville, Texas, Land Development Code
as to avoid nuisance conditions such as standing water, odors, insects, and weeds. A minimum slope
of 0.50% towards the outlet structure is required for all grass lined detention facilities.
4. Detention areas in parking lots shall not be:
a. In required parking spaces.
b. Behind speed bumps unless the speed bumps are made with reinforced concrete.
c. Deeper than six (6") inches unless otherwise approved by the Director of Public Works.
5. Drainage easements shall be provided for all regional detention/retention facilities and for other
detention/retention facilities where two or more owners are involved.
6. Individual detention facilities shall be designed to empty in less than three (3) hours, unless it is also
serving as an erosion control facility.
7. Detention facilities used as a sediment control facility shall meet the following requirements:
a. The sediment control facility shall be designed with minimal velocities such that sediment is
dropped and not picked up by flows at any time during the storm event.
b. The basin shall be designed with two (2) feet of sediment storage area so that sediment removal
is not required more than twice a year. Expected removal periods greater than twice a year must
be specified in the maintenance plan and approved by the Director of Public Works.
c. Sediment control facilities cannot be used to meet detention requirements unless the volume of
sediment is included in the calculations for the detention basin design.
8. The owner shall maintain detention/retention facilities unless the facilities are dedicated to the City of
Colleyville. Detention facilities must be properly maintained if they are to function as intended over a
long period of time. The following measures are required to ensure the facility functions properly.
a. Facilities should be mowed at least twice a year to control weeds and discourage woody growth.
b. Debris, litter and accumulated sediment should be removed from detention facilities at least twice
a year. Particular attention should be given to removal of debris, litter and sediment around outlet
structures. The Director of Public Works may require that the property owner remove said debris
when in the Director's determination that property damage or a flood hazard may exist.
c. Detention basins designed for sediment removal shall be maintained as specified in the
maintenance plan and approved by the City with construction plan submittal.
M. Flumes - The use of flumes is not recommended for widespread use. Flumes shall not be permitted
when the purpose of a permanent flume is to carry runoff down the sides of earthen channels.
1. A flume may be used to direct overflow runoff along property lines until the runoff can be intercepted
by streets or conduits. A flume shall not carry more than ten (10) cubic feet per second during the
one-hundred (100) year storm event with a slope of 1.00%.
2. All flumes crossing sidewalks shall be covered or bridged such as to minimize danger to pedestrians.
3. All edges are to be protected with rock rip-rap or other form of protection for erosion control and scour
purposes.
N. Lakes - Approval to develop in any area subject to inundation by a lake must be obtained from the
appropriate agency responsible for that particular lake before the city grants its approval. Agencies that
should be contacted include U.S. Army Corps of Engineers, Tarrant County Water Control Board, TCEQ,
the Trinity River Authority, and FEMA.
Regardless of approvals obtained from those agencies listed above, no filling, development or
Chapter 14 - Engineering Design Standards
Page 14 - 34
Co/leyville, Texas, Land Development Code
construction in any area subject to inundation by a lake shall occur without the approval of the City
Manager. The City Manager may require any studies necessary to determine that filling, development or
construction will not have a detrimental effect on adjacent, upstream or downstream properties and
buildings. This subsection in no way diminishes other requirements of this section.
O. Lot Drainaoe and Gradinq - Grading and drainage of all residential lots shall be designed in a manner
which will allow one lot to drain across an adjacent lot and into a permanent structure, such as a concrete
flume, lined channel, or proper inlet to an adequate drainage facility, or to a street right-of-way. If an
approved drainage structure is not present, it will be required of the developer to construct the necessary
facilities. (0-00-1261/12/19/00)
1. Sheet flow techniques shall be used for lot to lot drainage where possible. (0-00-1261/12/19/00)
2. Single lots shall accommodate their own drainage into an approved structure where topographic
elevations allow this to occur. (0-00-1261112/19/00)
Section 14-175 Miscellaneous
A. Trench Safety - In conformance with House Bills 662 and 665 as passed by the Seventieth Legislature
Regular Session of the State of Texas, all construction projects within the City of Colleyville or its
extraterritorial jurisdiction as provided by the Municipal Annexation Act (Article 970a, Vernon's Texas Civil
Statutes) shall contain provisions for trench safety. On construction projects in which trench excavation
will exceed a depth of five (5) feet, the uniform set of general conditions must require that the bid
documents and the contract include detailed plans and specifications for adequate safety systems that
meet Occupational Safety and Health Administration standards and that these plans and specifications
include a pay item for these same safety systems.
B. Underoround Utilities - All distribution lines, cables, etc. for utilities other than those listed above shall be
installed below ground within the subdivision. Transmission lines or major cables to provide utilities such
as electric, telephone, and cable television to the area as a whole may be located above ground on the
perimeter of the subdivision being served. The installation of these utilities shall conform to commonly
accepted construction standards and be subject to review by the Director of Public Works.
Section 14-180 Drainage Studies and Engineering Certification
A. Preliminary Drainaoe Analysis Guidelines - The purpose of a Preliminary Drainage Analysis is to
determine the need for drainage facilities and/or drainage easements either within the proposed
development or offsite. A Preliminary Drainage Analysis is required for every subdivision plat or a
development requesting a building permit on a parcel which does not have a previously approved
drainage analysis, unless the Director of Public Works has waived this requirement due to existing
conditions. The Preliminary Drainage Analysis shall consist of the following information:
1. A topographical map drawn at a scale of I" = 200' which depicts the watershed that drains to and
across the subdivision or development. The map must include the subdivision and an area extending
a minimum of 200' in all directions from the proposed subdivision. Sheets shall be either 18" X 24" or
24" X 36" in size and may contain sheet to sheet match lines. The map must include contour lines at
five (5') foot vertical intervals in terrain with a slope of two (2%) percent or more, or two (2') foot
vertical intervals in terrain with a slope of less than two (2%) percent. Data from the City topographic
maps will be acceptable where available. Data from USGS Quad sheets may be acceptable only
where City topographic maps are not available. The datum for "0" topography shall be that of the
United States Coast and Geodetic Surveyor the City of Colleyville GIS datum.
The map shall indicate any offsite or adjoining areas outside the limits of the area being developed
which are relevant to onsite drainage. Show all significant physical features such as proposed or
existing drainage and utility easements, water bodies, streams, railroads, parks, and drainage
ditches. Show location of existing utilities including gas and petroleum lines, electric, telephone and
Chapter 14 - Engineering Design Standards
Page 14 - 35
Colleyville, Texas, Land Development Code
TV cable. Also, the location of any existing structures located within the area being proposed for
development. The plan shall include the building footprint and parking areas when the Preliminary
Drainage Analysis is prepared for a building permit.
2. Calculation of the drainage areas, time of concentration, and storm water runoff rate for the 2, 5, 10,
25, 50 and 100-year frequency storms. The design calculations shall include preliminary locations of
drainage facilities. (0-00-1261/12/19/00)
3. Identification of special flood hazard areas as defined by the Flood Hazard Area Regulations
Ordinance and as located by the current Flood Insurance Rate Map.
4. The Preliminary Drainage Analysis shall be sealed by a Registered professional Engineer licensed by
the State of Texas.
B. Drainaqe Study Guidelines - A Drainage Study is required when it has been determined by the Director
of Public Works that the area being developed will require storm water drainage facilities or drainage
easements either within the development or offsite. The following criteria shall be used for the
developer's engineer to prepare a Drainage Study.
1. The study shall analyze the effect of the subdivision or the development on existing downstream
drainage facilities. The study shall be sufficient to verify compliance with the drainage design criteria
contained in this chapter.
2. The study shall include a topographical map as defined above in "Preliminary Drainage Analysis
Guidelines."
3. Delineation and calculation of drainage areas together with proposed flow arrows shall represent flow
patterns from runoff after all proposed improvements have been installed. Surface water drainage
patterns shall be shown for each and every lot in the proposed subdivision and for each lot adjacent
to the proposed subdivision.
4. In addition to those calculations required by the Preliminary Drainage Analysis, this study shall also
include:
a. Hydraulic calculations to each lateral, manhole, inlet and outlet structure on the pipe. Head
losses shall be calculated as described elsewhere in this chapter.
b. Inlet calculations utilizing the minimum time of concentration for the zoning type which is
contributing the largest "CA" to the inlet.
5. If any portion of the proposed subdivision or its offsite improvements (including pipes or ditches) falls
within the limits of a Federal Emergency Management Agency (FEMA) floodplain, additional
backwater calculations may be required. Additional calculations in the form of a Conditional Letter of
Map Revision will be required if:
a. Any portion of the proposed subdivision is determined to be located within a FEMA Zone "A"
floodplain; or
b. Any portion of the proposed subdivision is determined to be located within a FEMA Zone "AE"
floodplain and the overall subdivision (including all phases) is 5 acres or larger; or
c. Any portion of the proposed improvements from a subdivision include dredging or filling within a
FEMA designated floodway.
6. Backwater calculations shall comply with normally accepted standards as required by FEMA for
application for a Letter of Map Revision (LOMR). In addition, the calculations must begin with a
previously defined Base Flood Elevation (BFE). The calculations shall continue upstream through the
project until the proposed BFE is within .01 feet of the existing BFE or the limits of the existing Zone
'A' have been reached. A LOMR will be required prior to issuing building permits.
Chapter 14 - Engineering Design Standards
Page 14 - 36
Colleyville, Texas, Land Development Code
C. Certification - All drainage studies and/or plans including those which are part of a standard construction
plan submittal shall be sealed and signed by an engineer proficient in civil engineering and registered in
the State of Texas. All drainage submittals shall include the following certifying statement by the
"Engineer of Record".
I a Professional Engineer licensed in the State of Texas have prepared this
drainage study and/or plan in compliance with the latest published requirements and criteria of the City of
Colleyville, and have verified that the topographic information used in this study and/or plan is in compliance with
said requirements and is otherwise suitable for developing this workable plan of drainage which can be
implemented through proper subsequent detailed construction planning.
Signature
D. Disclaimer of Liabilitv - The degree of flood protection required by this policy is considered reasonable for
regulatory purposes and is based on scientific and engineering considerations. On rare occasions
greater floods can and will occur and flood heights may be increased by man-made or natural causes.
This policy does not imply that land outside the areas of street rights-of-way, drainage or flood plain
easements will be free from flooding or flood damages. This policy shall not create liability on the part of
the City of Colleyville, Texas or any official or employee thereof for any flood damages that result from
reliance on this policy or any administrative decision lawfully made thereunder.
Section 14-185 Amendments to This Chapter
Reserved for listing of amendments to this Chapter.
Ord. Number
0-00-1261
Date
12/19/00
0-01-1280
0-03-1403
01/08/01
05/06/03
Chapter 14 - Engineering Design Standards
Page 14 - 37
CITY COUNCIL
cc6@
7" L~:X" So
AGENDA BRIEFING
MEETING DATE:
ITEM # :
ORDINANCE #:
05/06/03
9
0-03-1404
CITY MANAGER I
DEPARTMENT HEAD! ~~
FINANCE REVIEW! N/A
Previous Action: N/A
DEPARTMENT: FINANCE
SUBJECT : Approval to amend Ordinance 0-92-880
establishing the fee structure for the circulation of
materials and replacement and processing fees for
materials for the Colleyville Public Library
First Reading and Public Hearing
As per the attached memorandum, the Colleyville Library Board recently approved the
Circulation Policies for the Colleyville Public Library including the fee structure for the books
and materials collection and the replacement and processing fees. (See attached). The
proposed fees are comparable to other area public libraries. Upon approval, staff will work
with The Library Corporation (TLC) to assist in programming the fee structure into the
integrated library system.
Financial Impact
The fees will be included as a source of revenue in the proposed FY 2003 -2004 budget.
Recommendation
Approval
Attachments
. Area Public Library Research and Analysis
. Colleyville Public Library - Staff Memorandum
. Ordinance 0-03-1404
:E
enW
..JI-
<(-en
-o::W
o::W-
Wa..o::
1--<(
<(>-0::
:E<(m
c-
Wo::..J
::JW<(
ca..W
0:: 0::
Wen<(
>W
QZ
u.
W
0:::
:::l
I- W
<C 0 0 ~ 0 0 0 0 0
w C! N .... N C! C! C!
u. ci u. ci ci
.... .... .... ....
I/) w w 0 w w w w w
0 Z
>
0
z
0
i=
() w
u. 0 0 z 0 0 0 0 0
z C! N u: .... ~ C! C! C!
0 .... ci 0 0 .... .... ....
z w w 0 w w w w w
I/) Z
0
>
0
UJ
()
5Q w
0
I- 0 0 z 0 0 0 It) 0
..-; ~ u. .... N .... N C!
() 0 0 ci ci ci ci ....
<C w w 0 w w w w w
Il. Z
:!
0
()
UJ W
~ 0 0 ~ 0 0 0 It) It)
.... ~ .... ~ .... ~ ~
0 ci u.
0 0 0 0 0 0 0 0
w w w w w w w
!Xl Z
UJ
..J
..J
J:
0
>- C Z
Z <C
!:: :::l ..J
() 0 W J: W
:! () ~
e z ii: <C
0::: (J) r:x: :> 0::: ..J
0 UJ W W I- W J: J:
u. w 3: c.. UJ ..J l- I-
e ..J 0 ~ 0::: ..J 0::: :::l
W :::l ..J :::l W 0 0
!Xl W u. C) J: ~ Z UJ
z
o
-
.....
<C
:E
~
o
LL
Z
wC/)
~w
<cO::
~~
><m
w-
........J
-<C
Ww
~~
.....<C
z
w
C
C/)
w
0::
I
Z
o
Z
I-
Z
c(
0-
U
i=
0:::
c(
0-
:1:
~
C) en en en 0 en 0 en en
0 w w w w w w
0::: >- >- >- Z >- Z >- >-
0-
Cl
0:::
c(
U
w
0:::
c(
J:
en
><
w
l-
I- e e e e
en c( C! c( c( e c( e c( e
0 - I.t) - - an - an - an
z N Z Z N Z N Z N
U ~ ~ ~ ~
e
0 Z
W Z I
W I ~
LL 11l C
Cl CI) en 0
0::: E w e .l!l e
c( U >- Z Z
U . . C I
- 11l CI) 11l
C 11l :2
I- CI) CI) IV en 0 en IV en
z E :E >< 11l W W >< W
W U CI) ~ >- z >- CI) >-
Cl CI) l- I-
CI) -
... C - ~ -
en Cl CI) 0 0
W c( E - c -
0::: c ~ C
I ni CI) CI) 0 CI)
z (.) CI) :2 u :2
...
0 0 Cl 11l C 11l
Z ... c( CI) CI)
c.. ... 0 ...
'(3 I -
C >. c >.
CI) 0 C CI) c
0::: Z c( Cl c(
en
..J
==
J:
Cl
>- Cl Z
Z c(
!::: ::::> ..J
U 0 W :I: W
:1: u ::s:::
Cl z ~ c(
0::: en 0::: :> 0::: ..J
0 en w w I- W J: J:
LL W 3: 0.. en ..J l- I-
Cl ..J 0 c( 0::: ..J 0::: ::::>
w ::::> ..J 0::: ::::> w 0 0
CC W LL C) J: ::s::: Z en
MEMORANDUM
TO:
Dianne McWethy, Deputy City Manager
FROM:
Mary E. Rodne, Library Director
DATE:
April 14, 2003
SUBJECT:
Proposed Colleyville Public Library Circulation Policy
In preparation of the Circulation Policy, staff reviewed comparable policies of
local libraries. General basic guidelines included in most policies of libraries in
this area were included in this policy.
For this policy, several decisions have to be made. These include: loan periods
for materials, item check out limits and fee charges.
In consideration of the above, staff developed two charts: Circulation Materials
Restrictions and Replacement and Processing Fees. In developing contents of
these charts staff considered the following:
'jr Fees and circulation loan periods of area libraries
'jr Proposed collection size of the Colleyville Public Library
On the basis of the above, staff proposed the attached Circulation Policy for
consideration.
COLLEYVILLE
PUBLIC LIBRARY
CIRCULATION POLICIES
o BORROWING PRIVILEGES
. ELIGIBILITY TO BORROW
Individuals presenting valid Colleyville Public Library cards are
eligible to borrow materials from the Colleyville Public Library when
the following conditions are met:
1 . No materials which are more than one circulation period
overdue on their card.
2. No outstanding fines in excess of the set threshold
(Appendix A).
The library staff may not waive these regulations without the
specific permission of the Library Director or his/her designee;
however, the patron may request and receive a 24-hour hold on the
item(s) he or she wishes to check out to allow the patron to correct
the situation, which has resulted in loss of eligibility to borrow.
Waiver of these regulations will be granted only if proof of mitigating
circumstances and proof of attempts to correct the situation are
presented to the Circulation Supervisor or his/her designee.
o LOAN PERIODS
The library's basic loan period is 14 days. Materials excepted from the basic
loan period may have loan periods of 3, and 7 days (Appendix A). Upon a
patron's request, extended loan periods for vacations may be made at the
discretion of a circulation staff member. Materials secured for a patron on
Interlibrary Loan are governed by the circulation policies of the home library and
must be returned to the home library on time.
o LIMITS ON BORROWING
The library reserves the right to limit the number of items in anyone subject area
of anyone medium that may be checked out to an individual patron, on the basis
of perceived demand for materials on that particular subject or in that particular
medium (Appendix A).
o RENEWALS
Circulation Policy
Revised 4/30/03
Page I of3
Most materials may be renewed, in person, by calling the Circulation Department
or online by using the patron's library card number and Personal Identification
Number (PIN). Library materials not reserved by another patron may be
renewed for additional loan periods (Appendix B). Materials that are on reserve
for another patron may not be renewed. Overdue materials will not be renewed
without payment of any overdue fines. Interlibrary Loan materials that are
overdue cannot be renewed.
o DRIVE - UP WINDOW SERVICE
The library has a drive-up window through which materials may be picked up
during library operational hours. For this service, patrons need to call ahead and
request staff to retrieve materials for window pick-up.
o MATERIAL RETURNS
The library has walk-up material returns inside the library and drive-up material
returns outside the library. Patrons will be credited with the return of the item on
the day it is put in the return. Items returned on a day the library is closed will be
checked in the next day that the library is open.
o OVERDUES
Materials returned after their due date will be assessed an overdue fine
(Appendix A) for each day the library was open between the due date and date of
return. A fine will not exceed the replacement cost of an overdue item. Overdue
notices will be sent out on the following schedule:
1st notice:
2nd notice:
3rd notice:
after materials are 7 days overdue.
after materials are 14 days overdue.
after materials are 21 days overdue.
If the materials are not returned one week after the 3rd notice is mailed, the
patron will receive a letter revoking their borrowing privileges.
o DELINQUENT PATRONS
All borrowing privileges will be suspended if a patron accumulates fines in excess
of the Library's threshold (Appendix A), or has unreturned materials for a period
exceeding 21 days. Borrowing privileges shall be reinstated upon return of the
materials and payment of the accumulated fees, or the payment of the
replacement cost of the material and the accumulated fees.
CIrculation Policy
Revised 4/30103
Page 2 of 3
o LOST AND DAMAGED MATERIAL
Borrowers are liable for the replacement cost of any library material lost,
damaged or not returned. The charge for replacement shall be the cost of the
material as noted in the item record of the Colleyville Public Library Online
Catalog. A processing charge (Appendix B) will be added to all items.
Borrowers who replace lost or damaged material with an exact copy will be
charged a re-cataloging fee (Appendix B). Library staff will determine if the
replaced material is an acceptable match. When material is returned with parts
missing, the patron is responsible for the cost of the part (Appendix B). If the part
is unavailable, the patron is liable for the replacement cost of the original
material, plus a processing fee.
o LOST AND PAID
If a patron recovers library material that has been lost and paid for within one (1)
month, the library will refund the cost of the material minus the processing fee.
The returned material and the dated receipt of payment must be presented at the
time of refund.
CIrculation Policy
Revised 4/30/03
Page 3 of 3
MATERIALS
Fiction Books
Non-Fiction Books
Best Sellers
Ma azines
Pam hlets
Feature Length
DVDs (60 min+
Educational/DVDs
Children's DVDs
under 60 min.
Com act Discs
J Kits
Books on Compact
Disc
J Holiday books
APPENDIX A
COLLEYVILLE
PUBLIC LIBRARY
CIRCULATING MATERIALS REST
LOAN PERIOD
LIMITS
FEES/FINES*
.25 per da
.25 per day
.25 per day
*Overdue fines threshold is $5.00.
** Renewals are allowed when materials are not on reserve for another patron.
3
3
14 da s
7 days
3
3
5
3
3
7 days
varies by
Holida
Appendix A Circulating Materials Restrictions
Revised 4/30/03
RENEWAL
L1MITS**
1
1
1
1
1
1
1
1
1
1
1
o during
Holida
APPENDIX B
COLLEYVILLE
PUBLIC LIBRARY
ITEM COST PROCESSING FEE*
Library Card $2.00 $0.00
Book Cost of item $5.00
Trade paperback book Cost of item $5.00
Paperback book Cost of item $2.00
Magazine Cost of item $2.00
Compact Disc Cost of item $5.00
Lost Insert Cost of item $1.00
Book on CD Cost of item $5.00
Lost/damaged CD Cost of sinQle CD $1.00
DVD Current cost of item $5.00
Audio-visual material containers Current cost of item $5.00
Bar Codes/RFID tags $1.00 $0.00
*If a replacement is purchased by the patron, the processing cost is $10.00
Appendix B: Replacement and Processing fees
Revised 4/25/03
Page I of2
ORDINANCE 0-03-1404
AN ORDINANCE AMENDING ORDINANCE 0-92-880 SETTING FEES AND
CHARGES FOR CITY SERVICES, ESTABLISHING SECTIONS OF THE CITY OF
COLLEYVILLE CODE OF ORDINANCES, TO BECOME EFFECTIVE UPON
PASSAGE
WHEREAS, the City of Colleyville charges fees for miscellaneous services and
materials as authorized by Ordinance 0-92-880 and it is desirous to add
to those fees for the opening of the Colleyville Public Library.
NOW, THEREFORE BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
THAT from and after the effective date of this Ordinance, Chapter 2
Section 2-26 (k) of the City of Colleyville Code of Ordinances shall be
established with the following additions:
(k) The following schedule of fees shall be administered by the Library
Director:
Colleyville Public Library Circulating Materials Restrictions (see
attached Exhibit "A")
Colleyville Public Library Replacement and Processing Fees
Materials (see attached Exhibit "8")
Sec. 2.
THAT this ordinance is effective upon passage.
AND IT IS SO ORDERED.
The first reading and public hearing being conducted on the
of 2003.
day
The second reading and public hearing being conducted on the
of 2003.
day
ATTEST:
CITY OF COLLEYVILLE:
Cynthia Singleton, TRMC
City Secretary
Mayor
Ordinance 0-03-1304
Page 2 of 2
APPROVED AS TO FORM AND LEGALITY:
Ross T. Foster
City Attorney
EXHIBIT "A"
COLLEYVILLE
PUBLIC LIBRARY
MATERIALS LOAN PERIOD LIMITS FEES/FINES* RENEWAL
L1MITS**
Fiction Books 1
Non-Fiction Books 3 1
__ __ ____m___H____~~._.~___.~____
Best Sellers 1
Ma azines 3 1
Pam hlets 1
Feature Length 1
DVDs 60 min+
Educational/DVDs 14 da s 3 1
Children's DVDs 7 days 3 1
under 60 min.
Com act Discs 5 1
J Kits 3 1
Books on Compact 3 1
Disc
J Holiday books 7 days varies by .25 per day o during
Holida Holida
*Overdue fines threshold is $5.00.
** Renewals are allowed when materials are not on reserve for another patron.
EXHIBIT "A": Circulating Materials Restrictions
Revlsed4/30/03
EXHIBIT "B"
COLLEYVILLE
PUBLIC LIBRARY
REP
ITEM COST PROCESSING FEE*
Library Card $2.00 $0.00
Book Cost of item $5.00
Trade paperback book Cost of item $5.00
i
Paperback book Cost of item $2.00
Magazine Cost of item $2.00
Compact Disc Cost of item $5.00
Lost Insert Cost of item $1.00
Book on CD Cost of item $5.00
LosUdamaged CD Cost of sinQle CD $1.00
DVD Current cost of item $5.00
Audio-visual material containers Current cost of item $5.00
Bar Codes/RFID tags $1.00 $0.00
*If a replacement is purchased by the patron, the processing cost is $10.00
FX:IIII~IT .. H" Rcpl8ccment and Processing lees
RevIsed 4/25/U3
P8g.e I of 2
CITY COUNCIL
cur Of
CCe'" AGENDA BRIEFING
1(,-.'\:.,$
MEETING DATE:
ITEM # :
RESOLUTION # :
05/06/03
10
R-03-2143
CITY MANAGER I
DEPARTMENT HEAD I
FINANCE REVIEW ! ·
Previous Action: None
DEPARTMENT: ENGINEERING
SUBJECT: Approval to amend Resolution R-02-1925
Authorizing the Approval of the 2001 Drainage Bond
Project List
Reading and Public Hearing
In January 2001, the City Council approved the 2001 Drainage Bonds and in March 2002
approved the Drainage Bond Priority List for the utilization of these bond funds. (See
attached). To date, several of the projects have been completed. The Jackson Road and
Cheek Sparger Road project is on hold. City resources will be used to complete the Cheek
Sparger and San Bar drainage improvements. The Bedford Road and Saddlebrook Entrance
project was funding with available MDUS funds for FY2002-03. Two of the projects (Jewell
Estates and Stonecrest) required less funding than the estimates.
Staff is proposing that the Drainage Bond Project List be amended to include funding for the
Welsh Circle drainage and related paving improvements in the amount of $102,763. (See
attached).
Recommendation
Approval
Attachments
· Resolution R-02-1925
· Resolution R-03-2143
RESOLUTION R-02-1925
A RESOLUTION AUTHORIZING THE APPROVAL OF THE 2001 DRAINAGE BOND
PROJECT LIST
WHEREAS, In January 2001, City Council approved the 2001 Drainage Bonds; and
WHEREAS, In February 2001, a worksession was held with City Council to discuss
drainage problems and total construction cost estimates with the intent of
generating a project list; and
WHEREAS, In February 2002, a worksession was held with City Council to present a
project list with estimates and construction schedules for ten (10) drainage
projects identified from the Master Drainage Priority List; and
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
THAT the Drainage Bond Priority List, hereby referred to as Exhibit" A" for
the 2001 Drainage Bonds. is hereby approved.
AND IT IS SO RESOLVED.
PASSED BY A VOTE OF 5 AYES, 0 NAYS, AND 0 ABSTENTIONS ON
THIS THE /9~ DAY OF ~..., 2002.
ATTEST:
t2 Sin9~lon,
City Secretary
.~
CITY OF COllEYVlllE
~;Np
Mayor
Exhibit "A"
Drainage Bond Project Priority List
Projects Estimates
> John McCain Road @ Hwy 26 Realignment $450,000.00
> Jewel Estates Drainage Improvements 380,000.00
> Little Bear Creek Restudy and Letter of Map Revision 50,000.00
> Jackson Road Drainage Improvements (Cheek Sparger and 200,000.00
Jackson Road Intersection Improvements)
> L.D. Lockett Drainage (Hunter Trail to Quality Hill) 100,000.00
> Felps Drive (flooding of private residence) 75,000.00
> Cheek-Sparger and Sanbar Drainage Improvements 100,000.00
> Stonecrest Estates Drainage (private property damage) 75,000.00
> Bedford Road @ Saddlebrook Entrance (groundwater) 25,000.00
> John McCain Road Channel Improvements 20,000.00
(adjacent to Coptic Church)
Total $1,475,000.00
RESOLUTION R-03-2143
A RESOLUTION AMENDING RESOLUTION R-02-1925 AUTHORIZING THE
APPROVAL OF THE 2001 DRAINAGE BOND PROJECT LIST
WHEREAS, the City Council desires to amend the Drainage Bond Project List to
address drainage problems within the City.
NOW, THEREFORE, BE IT RESOLVED BY CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
THAT the 2001 Drainage Bond Project List, hereby referred to as Exhibit
"A" for the 2001 Drainage Bonds, is hereby approved.
AND IT IS SO RESOLVED.
PASSED BY A VOTE OF
THIS THE DAY OF
AYES,
NAYS AND
2003.
ABSTENTIONS ON
ATTEST:
CITY OF COLLEYVILLE:
Cynthia Singleton, TRMC
City Secretary
Mayor
Exhibit A
Drainage Bond Project Priority List
The following drainage project list has been revised to show actual costs or project status:
Total Bond Monev Available:
Projects:
>- John McCain Road @ Hwy 26 Realignment
>- Jewel Estates Drainage Improvements
);> Little Bear Creek Restudy and Letter of Map Revision
);> Jackson Road Drainage Improvements (Cheek-Sparger and
Jackson Road Intersection Improvements)
);> L.D. Lockett Drainage (Hunter Trail to Quality Hill)
>- Felps Drive (flooding of private residence)
>- Cheek-Sparger and Sanbar Drainage Improvements
>- Stonecrest Estates Drainage (private property damage)
);> Bedford Road @ Saddlebrook Entrance (groundwater)
);> John McCain Road Channel Improvements
(adjacent to Coptic Church)
New Project:
);> Welsch Circle & Montford Drive Drainage Improvements
Projects Estimate
Money Available
Actual Project Costs
Balance
$1~600~OOO
Estimate (Actual)
$650,000 (pending)
$380,000 ($215,000)
$50,000 <$52,000>
$200,000 (on hold)
$75,000 <$230,000>
$50,000 (pending)
$75,000 (City crews)
$50,000 ($23,000)
$25,000 (other $$)
$20,000 (pending)
$102,763 (Pending)
$1.575.000 (estimate)
$1.600.000
$1.240.763 (actual)
$359,237
CITY COUNCIL
cc@n~ AGENDA BRIEFING
1C";(:tS
MEETING DATE:
ITEM # :
RESOLUTION# :
05/06/03
11
R-03-2144
!
CITY MANAGER i
I
DEPARTMENT HEAD I
I
FINANCE REVIEW I
;
Previous Action: None
DEPARTMENT : ENGINEERING
SUBJECT: Approval of a Construction Contract for the Welsh
Circle Paving Improvement Project with J. L. Bertram
Construction and Engineering, Inc., in the amount of
$102,763
Reading and Public Hearing
In February 2002, City Council approved a list of ten projects to utilize the $1.6 million in
drainage bond funds. Over the past year some of the projects included in the original list have
been constructed and completed below the engineer's estimates. This has allowed some
additional projects to be considered for construction with the remaining funds.
Staff met with citizens in the fall of 2002 at Welsh Circle and Montford Drive regarding standing
water and improper drainage within the roadway. The current roadway has developed a sag in
the gutter line and holds rainwater for weeks at a time until it evaporates. During the rainy
season it will not dry up. The streets are asphalt and water has continued to undermine the
road at this location causing deterioration of the subgrade, resulting in a greater problem.
Construction will consist of removing and replacing the existing pavement with concrete and
adjusting the grade to create positive drainage. All driveways, irrigation systems and
mailboxes adjacent to the improvements will also be adjusted.
Staff has met with the citizens and discussed the proposed improvements. Comments were
received and addressed and the project was advertised in March 2003. Three bids were
received and opened on March 25, 2003, with Boatner Construction Services being the low
bid. However, numerous attempts to collect necessary background information and references
from Boatner failed. Also, their bonding company is not listed with the U.S. Treasury;
therefore, Boatner Construction Services was deemed non-responsive and the second low
bidder, J.L. Bertram Construction and Engineering, Inc. was selected for consideration.
The contract amount is $85,635.56 with a 20% contingency of $17,127 for a total of $102,763.
A 20% contingency is needed due to the work being performed in a residential area.
The City Attorney has reviewed and approved this contract.
Agenda Briefing
Resolution R-03-2144
Page 2 of 2
Financial Impact
Funding is available from the 2001 Drainage Bonds
Recommendation
Approval
Attachments
. Bid Tabulation
. Resolution R-03-2144
BID TAB
Owner: City of Colleyville
Engineer: Teague, Nail, & Perkins
Project: Welsh Circle Paving Improvements
Bid Date: Tuesday, March 25, 2003
No. Bidder Bid Bond Bid Amount
1 Boatner Construction Services $66,126.00
2 J.L. Bertram Construction & Engineering, Inc. $85,635.56
3 Humphrey & Morton Construction Co., Inc. $94,841.60
4
5
6
7
8
RESOLUTION R-03-2144
A RESOLUTION AUTHORIZING THE APPROVAL OF THE CONSTRUCTION
CONTRACT WITH J.L. BERTRAM CONSTRUCTION & ENGINEERING, INC., FOR
THE WELSH CIRCLE PAVING IMPROVEMENT PROJECT
WHEREAS, the construction bids for the Welsh Circle Paving Improvements were
received on March 25,2003; and
WHEREAS, three bids were submitted; and
WHEREAS, J.L. Bertram Construction & Engineering, Inc., is the selected bid.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
THAT the construction contract with J. L. Bertram Construction &
Engineering, Inc., for the Welsh Circle Paving Improvement Project, in the
amount of $102,763, is hereby approved.
AND IT IS SO RESOLVED.
NAYS, AND
2003.
PASSED BY A VOTE OF
ABSTENTIONS ON THIS THE
AYES,
DAY OF
ATTEST:
CITY OF COLLEYVILLE
Cynthia Singleton, TRMC
City Secretary
Mayor
CITY COUNCIL
ccecel AGENDA BRIEFING
'C':ens
I
MEETING DATE: I
I
05/06/03
12
R-03-2145
CITY MANAGER I
I
ITEM # : i
i
RESOLUTION # : !
DEPARTMENT HEAD I
I
FINANCE REVIEW i
Previous Action: None
DEPARTMENT: PUBLIC WORKS
SUBJECT: Approval of an Interlocal Agreement with Tarrant
County for Glade Road, Rose Street, Cherry
Avenue, Lowrie Road and Reagan Road
improvements, in an amount not to exceed $65,000
Reading and Public Hearing
The City of Colleyville has entered into several interlocal agreements with Tarrant County in
recent years regarding road improvements. Bransford Road south of L.D. Lockett (1999),
Bandit Trail (2002) and including John McCain Road (2003). Each project was completed at a
considerable cost savings to the City. The County provides all of the labor and equipment to
conduct the improvements and the City is responsible for traffic control and material testing.
Tarrant County is in the process of setting their summer construction schedule. The City has
submitted to the County a list of roads that include: 1) the west end of Glade Road; 2) Rose
Street; 3) Cherry Avenue; 4) Lowrie Road; 5) Reagan Road. The repair work will include the
removal and haul off of the existing top course of asphalt, stabilizing, re-grading and re-
compacting the subgrade and applying a 2-inch HMAC overlay.
This type of project is a new addition to the City's annual street rehabilitation program and is
consistent with the Colleyville Public Works Department procedures. The remaining street
rehabilitation fund balance will be used this summer for repairs in other locations in which
Tarrant County cannot participate due to workload issues.
Financial Impact
Funding is available from the Street Department Resurfacing Budget (001-33-6319).
Recommendation
Approval
Attachments
. Interlocal Agreement
. Cost Estimate
. Resolution R-03-2145
THE STATE OF TEXAS
KNOW ALL MEN BY THESE PRESENTS
COUNTY OF TARRANT
CONTRACT
This Agreement made and entered into this the
day of
, 2003, by and between the County of Tarrant, acting herein by and
through its governing body the Commissioners Court, hereinafter referred to as TARRANT
COUNTY, and the CITY OF COLLEYVILLE acting herein by and through its governing
body, hereinafter referred to as THE CITY, both of Tarrant County, State of Texas,
witnesseth:
WHEREAS, this Agreement is made under the authority granted by and pursuant to
Chapter 791 ofthe Texas Government Code; and
WHEREAS, the party or parties paying for the performance of governmental
functions or services shall make payments therefore from current revenues available to the
paying party; and,
WHEREAS, the governmg bodies of the two parties find that the project or
undertaking is necessary for the benefit of the public and that each party has the legal
authority to build or maintain the project or to provide such service, and the construction and
improvement thereof is in the common interest of both parties hereto; and that the division of
costs provided for constitutes adequate consideration to each party; set project being more
particularly described as:
. Construction of a HMAC overlay on Glade Road, west of the Mill Creek Sub-
Division (approximately 350 linear ft.).
. Rehabilitation of Lowrie Road, from L.D. Lockett Road to the Tarrant County
maintenance line (approximately 1228 linear ft.).
. Rehabilitation of Reagan Road, from L.D. Lockett Road to the Tarrant County
maintenance line (approximately 1228 linear ft.).
. Rehabilitation of Cherry Avenue, from Bluebonnet Road to the end of street
(approximately 1273 If.).
. Rehabilitation of Rose Street, from Glade Road to Cherry Avenue (approximately
1025 linear ft.).
WHEREAS, the parties hereto, in order to facilitate the financing and construction of
the needed facility, and in order to share the costs of having said work to be done have
agreed to share in the financing of said construction as hereinafter stated in detail.
The CITY hereby agrees that the CITY will pay for any engineering, survey, and
laboratory testing necessary for these projects, and that the COUNTY will not be responsible
for any payment for such services. The CITY must notify the COUNTY within thirty days
of completion of this project of any complaint the CITY has with the project.
For and in consideration of the mutual undertaking hereinafter set forth and for
adequate consideration given, the parties agree as follows:
1. TARRANT COUNTY agrees to provide the work for the following projects:
A. Glade Road.
Remove the existing HMAC surface and place a two-inch HMAC
overlay surface.
R Lowrie Road:
Reclaim the existing roadbed materials, incorporate and stabilize the
recycled base material with cement, re-grade and place a two-inch
HMAC surface.
C. Reagan Road:
Reclaim the existing roadbed materials, incorporate and stabilize the
recycled base material with cement, re-grade and place a two-inch
HMAC surface.
D. Cherry Avenue:
Reclaim the existing roadbed materials, incorporate and stabilize the
recycled base material with cement, re-grade and place a two-inch
HMAC surface.
E. Rose Street:
Reclaim the existing roadbed materials, incorporate and stabilize the
recycled base material with cement, re-grade and place a two-inch
HMAC surface.
2. TARRANT COUNTY agrees to provide the labor and equipment necessary
for the rehabilitation work of above projects.
3. The CITY agrees to pay for the actual cost of the materials, including any
delivery or freight costs. The CITY will provide a purchase order and will be
billed directly by the material supplier. The County may accumulate and bill
the City for incidental material cost.
4. The CITY agrees it will be responsible for traffic control on these projects.
This responsibility includes all signage, barricades and flagmen necessary to
control traffic in and around the construction site. The CITY will also be
responsible for all striping (both temporary and permanent) for the project.
5. The CITY will provide the county with a hydrant meter and all the water
necessary for the projects at no cost to the county.
6. The CITY will be responsible for all storm water pollution documentation and
for installation, maintenance and removal of all storm water pollution
prevention devices as required.
By entering into this Agreement the parties do not create any obligations express or
implied other than those set forth herein and this Contract shall not create any rights in
parties not signatories hereto.
The parties to this Agreement do not intend by this Agreement that any specific third
party may obtain a right by virtue of the execution or performance of this Agreement. CITY
agrees that the COUNTY is relying on the CITY for notice of when to proceed with these
projects, but this Agreement does not require the County to do these projects with any
particular time frame.
This Agreement shall terminate automatically upon happening of any ofthe following
events:
1. The completion of the improvement provided for herein or;
2. At the end of one (1) year from date herein, unless renewed by both parties in
writing.
CITY:
Authorized City Official
ATTEST: CITY
TARRANT COUNTY:
TOM VANDERGRIFF, County Judge
ATTEST: COUNTY
B. GLEN WHITLEY, County Commissioner
Precinct Three
* APPROV AL AS TO FORM:
District Attorney's Office
* By law, the District Attorney's Office may only advise or approve contracts or
legal documents on behalf of its clients. It may not advise or approve a contract or
legal document on behalf of other parties. Our review of this document was
conducted solely from the legal perspective of our client. Our approval of this
document was offered solely for the benefit of our client. Other parties should not
rely on this approval, and should seek review and approval by their own respective
attorneys.
2003 Overlay Project
w I Tarrant County
Cost Summary
.1II1..Il~II.IIII~t1ml~:...um
Glade Rd
Cher Avenue
Rose St
Lowrie Rd
Rea an Rd
subtotal
10% contingencies
$2,810
$16,201
$12,187
$14,209
$13,119
$58,526
$5,853
$64,379
Total
The Cit
The Cit
The Cit
350
1273
1025
1228
1228
5104
RESOLUTION R-03-2145
A RESOLUTION AUTHORIZING THE APPROVAL OF AN INTERLOCAL
AGREEMENT WITH TARRANT COUNTY FOR GLADE ROAD, ROSE STREET,
CHERRY AVENUE, LOWRIE ROAD AND REAGAN ROAD STREET REPAIR
IMPROVEMENTS
WHEREAS, Tarrant County will perform repair work at the west end of Glade Road,
Rose Street, Cherry Avenue, Lowrie Road and Reagan Road; and
WHEREAS, Tarrant County will provide the labor and equipment required to construct
the planned improvements; and
WHEREAS, the City will provide the materials testing, traffic control during the
construction; and
WHEREAS, the City will issue a notice to proceed for the County to begin after
approval of the interlocal agreement; and
WHEREAS, the work will be completed by the end of September 2003.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
THAT the Interlocal Agreement with Tarrant County for street repair
improvements, in the amount not to exceed $65,000, is hereby approved.
AND IT IS SO RESOLVED.
PASSED BY A VOTE OF
THIS THE DAY OF
AYES,
NAYS AND
2003.
ABSTENTIONS ON
ATTEST:
CITY OF COLLEYVILLE:
Cynthia Singleton, TRMC
City Secretary
Mayor
CITY COUNCIL
c\tYor
CC~~ll AGENDA BRIEFING
IL'X~S
MEETING DATE: '
ITEM # :
RESOLUTION # :
05106/03
13
R-03-2124
CITY MANAGER I
DEPARTMENT HEAD
FINANCE REVIEW I
DEPARTMENT: COMMUNITY DEVELOPMENT
SUBJECT: Reconsideration of the City Council action taken on
a request for waiver of perimeter street improvement
requirements on Lot 3R, Block 2, Thompson
Terraces, located at 5009 Thompson Terrace
Previous Action: Tabled 04/15/03
Update
The City Council tabled action on this request when the applicant was called away from the
meeting unexpectedly and was not available to finalize the discussion regarding his request for
a waiver of the perimeter street improvement costs. Additionally, there was misunderstanding
regarding the method for applying perimeter street improvement costs to reduce roadway
impact fees. The property contains approximately 180 linear feet of street frontage, which after
applying the per-front costs of $134.98, requires a perimeter street improvement cost of
$24,295.50. Since Thompson Terrace is a collector street shown on the Master Thoroughfare
Plan, the actual perimeter street improvement costs are used to reduce any applicable
roadway impact fees collected at time of building permit. The applicant proposes to construct
a new office building on the property containing 4,689 square feet, which would require the
collection of a $12,107 roadway impact fee ($2,582 per 1,000 s. f. of floor area). State laws
pertaining to roadway impact fees require developers be given credit against roadway impact
fees for any perimeter street improvement costs. Thus, the roadway impact fee is reduced to
zero, and the developer would pay the perimeter street improvement costs.
The developer is requesting a waiver or reduction of the $24,295.50 perimeter street
improvement costs.
Reading and Public Hearing
At the April 1, 2003, meeting, the City Council denied a request for a waiver of perimeter street
improvement requirements for property located at 5009 Thompson Terrace. The applicant, Dr.
Jonathan Richard, was not able to attend the April 1 meeting due to family medical reasons.
He has submitted a letter asking that the City Council reconsider the request so he may
present his case and discuss the issue with the Council. A copy of the letter is attached.
Dr. Michael Richard is the owner of a lot located on the east side of Thompson Terrace,
between Glade Road and Colleyville Boulevard. The owner submitted a minor plat of the
property that created one non-residential lot for the construction of a medical office. The
Planning and Zoning Commission approved the minor plat at the December 2, 2002 meeting.
Agenda Briefing
Resolution R-03-2124
Page 2 of 2
The owner is seeking a waiver of perimeter street improvement requirements for this property.
Dr. Richard does not own any contiguous property, and a letter from the owner is attached that
describes this request in further detail. The owner dedicated 1,350 square feet of right-of-way
for Thompson Terrace on the plat. Thompson Terrace is identified for future widening on the
Master Thoroughfare Plan, though no plans for improvement have been authorized. The
future right-of-way for Thompson Terrace is 75 feet. Thompson Terrace is an asphalt street
without curb or gutter. The future street would be constructed of concrete. The following
tables show the pertinent data relative to this request.
Perimeter Street Improvement Cost Estimate
STREET FRONTAGE TOTAL ESTIMATE ACTUAL COST PER LINEAR FOOT
Thompson Terrace 180.0 feet $ 24,295.50 $134.98
One of the responsibilities of a property owner when property is proposed for platting is to
make improvements to adjacent streets if the streets are not currently constructed to City
codes. Generally, streets are considered unimproved if the street is not concrete and does not
have curb and gutter. Instead of improving the streets, the owner may escrow an equivalent
amount of money with the City to meet this requirement. The escrow amount, which is based
on the City's costs to construct a similar type of roadway, includes both construction and
engineering design costs.
Dr. Richard has appealed this requirement as allowed by the Land Development Code. The
Land Development Code gives the City Council the authority to consider a waiver from this
regulation, as the Council is the appeals body for Chapter 9 of the Code, in which this
regulation is contained.
The City Council's options in this case are the following:
1. Approve the waiver as requested - This action would waive the perimeter street fee
requirement for this property in the amount of $24,295.50.
2. Approve the waiver in part - The Council may waive a portion or percentage of the fee.
3. Denv the waiver - The property owner must escrow $24,295.50 with the City before
building permits could be issued on the property.
Recommendation
Denial
Attachments
· Location Map
· Letter from Applicant
· Property Map
· Resolution R-03-2124
10 ~I ' ~.
CO I,\..
@
- '2'\; ~
I\.. l3?t "el
~\3' . S~~20G
.
.
TR 4Al :
.58 .., AC :
II{; ,
.
TR U
I. IS At
TR ]t
.61 At
) ~Ot8>O\..
'l SC
1
I 8._ .
:P
1l\?J
.J 0\..501'1
p (1
SiJF\l2~B ~..
(-I' 1 ~
.....
of\R1<
'f~Fr
Cf.~ r.. VVt'l_
t" .....-;:;"f)
on
8,QI)"4 .
_ cz, '( ~otJ
_...,1.
l\.
Location Map
CASE # P-02-045 - Amended Plat - Thompson Terraces
April 7, 2003
To Whom it May Concern:
We would respectfully request the city council to reconsider ourrequest
for waiver for the assessment of street improvements as outlined in our
letter of March 6, 2003.
Due to medical reasons, we were unable to attend the city Council meeting
of last Tuesday, April 1st. We would like to be able to present our
position in person and discuss any alternatives that might be in both of our
interests.
;~C;rlY,
\.. ...' / ,/ 'It
a~ an & Marietta Richard
R' EC.E'ED'
I r~~ 8Z~ l '
\ ~ _______ - -. J
! u IY OF COlLEYVILL-
'>,)MIVlUNiTi DEVELOt)..,,\HH
March 5, 2003
City of Colleyville
5400 Bransford Rd.
P.O. Box 185
Colleyville, Texas 76034
RE: Richard property on Thompson Terrace
I am a long time resident of Colleyville and the current owner of the
property at 5009 Thompson Terrace. At considerable time and expense I
have endeavored to develop this property to better meet the needs of my
patients and keep my practice within the city of Colleyville. As I have 3000
active patients coming to my office from over 12 nearby cities, the
development of this property will be convenient for my patients and
greatly enhance the visibility of other small business in downtown
Colleyville and the nearby Villages of Colleyville.
I submitted a minor plat to the City of Colleyville to combine two lots into
one in order to build a small professional office building. The Planning and
Zoning committee approved the plat at the October 12, 2002 meeting.
After completing the platting process and donating the right of way to the
City for future street improvements, I was surprised to find that I was still
required to pay a $25,000 fee for additional improvements. As a solo
practioner with a small medical practice, which requires over 80 hours per
week of my time, this is a huge financial burden. Due to the increasing
time and financial pressures of running a medical practice, had I known
about this additional expense from the beginning, I probably would not
have pursued the development of this property in Colleyville.
I am concerned that further delay and additional expense may adversely
impact my ability to meet the needs of my patients, therefore, I am
requesting that the City Counsel grant a waiver of the perimeter street
improvement requirement for this plat as allowed by the Land
Development Code.
. ~,erel~
J6nathan Richard, M.D.
IR ErE' '''0'
'. ,>-" . ~ : -"..
r~m 12003 T
I I... c ...< .-..... ... .':
j 'l (I f rOll l (VIt,I ~,1~! INri DE'IF! ',;i
I
'/2. I I
I
/J!F.
I
I
I
I. 60.08' I
I
I; I
I
~I.
t;jl
w
:1
'"
I!! I
z
---I ~I
I
w I
u
<( I
0:::: I
0::::
W
l- I
Z I
0
if) I
0.... I
~
___---l 0
I J: I
l- I
I
I
I
I. I
60.04' I
I
--~/~ I
I
I
I
I
I
I
I
I
I
I
I
I : 1~ ~~NAOC ~~~T I
VOL 388-11, PG. !!It
~~.~:_-~~;--+-J~~~~~~~~j~~;~~~~~~~~~~~~," ~
-- --~-109~----- 1/2"'RF-
- -----i--------~------------------l
P.D.B. 1 T I
I I I : I
~I I~ I i I~
CO ~ I I
-I I I
I · , : i
I I~ I :
1 I; I i ~
I I'i : ! I
Q I I -
I ~ I .. I
1 ai I I rl 1
I~ so C) C) I i
II! I .:1'1; . . LOT 3R eo ~,,,,:i:,: !!
15 0.4504 AC. (19.620 sa. FT.) I!
I I I : I ~
: ! I : !
I ~ I I :
~ I I
1 ~ I I
" I I
ill' : i
1 I 1
j!:1 I I : L- --
~I I~ : i 18 ':~
I I I I lei
I I : 1!1
'/2' I""j 1_ 109.00' ---.L-=:l
· ~O~ - +- - - ---P"CPE"~ ~ - - - - 'WEST'"II'/2. I,.,.
I I : I
I I I I
I :
I :
I LOT 2 :
I :
I BLOCK 2 :
THOMPSON TERRACES
I VOL. 388-1', PG. 81 :
P.R. T.C. T.
I :
I :
LOT 5
I
',\
L i
--j
37.50'
I
f
~
,~
1;:
:~~
'>1
~
*
i
~
~'
t.'
\'<
:~
i'
~.
~
f
'*
1f~
~
'~
If
1fi
*"
~.
~'
'\
~
~:
.~
l
j
j,i;
%.
~
;iti'
~
.~
i
I
,~
-it
.
RESOLUTION R-03-2124
A RESOLUTION APPROVING A WAIVER OF
PERIMETER STREET IMPROVEMENT REQUIREMENTS FOR
LOT 3R, BLOCK 2, THOMPSON TERRACES
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
THAT the City Council has reconsidered the action taken on the denial of the
waiver of perimeter street improvement requirements at the April 1, 2003
meeting; and
Sec. 2.
THAT the perimeter street improvement requirements for Lot 3R, Block 2,
Thompson Terraces, are hereby waived.
AND IT IS SO RESOLVED.
NAYS AND
2003.
ABSTENTIONS ON
PASSED BY A VOTE OF
THIS THE DAY OF
AYES,
ATTEST:
CITY OF COLLEYVILLE:
Cynthia Singleton, TRMC
City Secretary
Mayor
.~
Texas
PLANNING AND ZONING COMMISSION
MEETING MINUTES - MARCH 24, 2003
CALL TO ORDER
Chairman Wall called the meeting to order at 7:00 p.m.
ROLL CALL
Commissioners Bruce Kelly, Earl Swift, Jeff Byerly, Bud
Seller, Mark Jones, and Jeff Wall were present.
Barry LeBaron, Clayton Husband, Jeff Jones, and Jan Levy
from staff were present.
INVOCATION
The invocation was given by Commissioner Swift
PLEDGE OF ALLEGIANCE
APPROVAL OF MINUTES
March 10,2003
Commissioner Swift moved to approve the minutes as amended to add a statement to the
motion on item #4. Commissioner Byerly seconded the motion. The motion passed by
unanimous acclamation.
CITIZEN COMMENTS
There was none.
AGENDA ITEMS
Chairman Wall announced that the applicant for agenda item 4 has requested that the
Planning and Zoning Commission not take action on the case, but table the case do to the fact
that the architect for the project would not be able to attend the meeting. He said it would not
be fair to the people who came to speak about the case nor to the applicant to hold the public
hearing since the applicant could not respond to the speakers.
Chairman Wall moved to table item #4, Case Z-03-008, until the April 14, 2003 meeting.
Commissioner Jones seconded the motion. The vote being:
Ayes: Kelly, Swift, Byerly, Sellers, Jones, Wall
Noes: None
Chairman Wall advised staff to resend the notice of public hearing to the surrounding property
owners.
Planning & Zoning Commission
Minutes - March 24, 2003
Page 1 of 8
Approved on Apri/14, 2003
1. Case P-03-008 - Minor Plat of Mockingbird Hill Addition, 10.6898 acres located on the
west side of Pool Road in the 3400 block
Clayton Husband presented the case to the commissioners and reviewed the staff briefing.
There were no questions by the commissioners.
Commissioner Kelly moved to approve the minor plat. Commissioner Swift seconded
the motion. The vote being:
Ayes: Kelly, Swift, Byerly, Sellers, Jones, Wall
Noes: None
2. Case Z-03-006 - PUBLIC HEARING - Zoning Change from CN to PUD-R, 2.05 acres
located at the northeast corner of Cheek Sparger Road and Steeplechase Drive
Clayton Husband presented the case to the commissioners and reviewed the staff briefing.
Commissioner Sellers asked Fire Marshal Jones if he was satisfied with the one entrance into
the subdivision and about the turning radius. The Fire Marshal said the Land Development
Code does not require more than one entrance for only ten lots and the houses are not
required to have interior fire sprinkler systems. He said the street is not long enough to require
a full turning radius in the cul-de-sac.
Commissioner Jones said there are unique parcels in the city yet to be developed and he is in
favor of bending a few rules in order to develop those properties; however, this proposal
appears to be fracturing the rules. Staff responded there are other approved developments
that have similar lot sizes. They mentioned the Villas at Caldwell's Creek and Westgate Villas;
however, these subdivisions have open space and the proposed subdivision does not.
Chairman Wall opened the public hearing. Those present wishing to speak were:
Jimmy Schnurr, applicant. Commissioner Jones asked if it was possible to have open space in
the subdivision. Mr. Schnurr said it was not economically viable. He explained that Boardwalk
Homes is purchasing the property under commercial rates, yet they believe strongly the area is
a residential area and not designed for commercial development. He said it is not a good
commercial site as it has residential development on three sides. He explained there would be
ten custom-built single family homes, with no two story structures, in the $300,000 range. Mr.
Schnurr said the only access to the property is from Cheek Sparger Road since Bridlewood
Estates owns the brick wall that runs along the western property line. He said that a
commercial development on the property would generate more traffic than ten residential lots.
He said he spoke with Bridlewood Estates, The Woods of Colleyville, Wood briar Estates and
Saddlebrook Estates Home Owner Association representatives and the developer plans to
mirror the Bridlewood HOA deed restrictions. He said this would be a high quality project that
will benefit the area.
Planning & Zoning Commission
Minutes - March 24, 2003
Page 2 of 8
Approved on Apri/14, 2003
Commissioner Sellers asked about the positioning of garages.
Monty Thomason, Vice President of Boardwalk Homes, explained this would not be a gated
community and the average home would be approximately 2,400 square feet and start at
$290,000. He said there would be no front entry garages, but they would probably have a front
swing garage entry.
Jo Ann Gasper, 4103 Paddington Way, said she would like the property to develop residential;
however, there may be a line of sight problem when existing off Steeplechase. She expressed
concerns about density and she encouraged the Commission to include the deed restrictions
within the approving ordinance.
Steve Knight, 3917 Felps Court, expressed concerns about commercial zoning in the area and
said he believed that residential would be the highest and best use of the property. He said he
has concerns about the density and said the developer commented that fewer lots were not
viable because of the commercial rates. He said the developer should not pay commercial
rates and he advised the Bridlewood homeowners to hold out for a better proposal for a
residential subdivision on the property with fewer lots. He said they should not feel as if this is
the only thing that could be developed on the property.
Tom Caunitz, 4006 Steeplechase Drive, said his house would face the back corner of the
development and he would be looking at the rear of houses. He said when he saw the
pictures of proposed home designs, he thought there would be nice looking houses, but he is
concerned about the number of houses.
Pam Brandon, 3608 Briarbrook Court, said she is the president of the Woodbriar Homeowners
Association and they discussed the proposal at a Board meeting. She said there are concerns
about the speed of cars on Cheek Sparger and the number of accidents due to the curve in the
roadway. She said something needs to be addressed about the road alignment for safety
reasons.
Steve Lingard, 301 Bridlewood South, said he lives on the corner on Lot 1. He asked
questions about the distance from the fence to the rear of the houses, and about the proposal
for a 112 story house on the rear lots within the subdivision. He said he did not want someone
to have full view into his property. Mr. Lingard also expressed concerns about traffic and
speeding on Cheek Sparger.
Robert Peters, 4000 Steeplechase Drive, said he would also be facing the back yards of the
proposed homes. He said he sent a letter to the commissioners proposing a different layout
for the subdivision that will create a horseshoe drive around the houses.
There being no one else present wishing to speak, the public hearing was closed.
Commissioner Swift said he thinks that single family homes should be built in this area;
however, he has issues about density, lack of open space, and the precedent it will set by
creating such a high density with the adjoining property that still has the potential for being
developed. He said this would be a big mistake.
Planning & Zoning Commission
Minutes - March 24, 2003
Page 3 of 8
Approved on Apri/14, 2003
There was discussion about the vacant lots in the area and the plans for development in the
area.
Commissioner Kelly said the Master Plan is currently being updated and they have no way of
knowing what that plan will look like. He said the concerns about traffic are valid and if this
property is developed, the traffic may turn out into an area of Cheek Sparger that needs to be
aligned as required by a new Master Plan.
Commissioner Jones moved to deny the zoning change. He said the area may be
appropriate for residential development, but there are too many other issues with the request.
Commissioner Swift seconded the motion.
The applicant addressed the Commission and asked that the request be tabled so that they
may continue to work with the surrounding neighbors and address their concerns.
Commissioner Jones withdrew his motion. Commissioner Swift said he would not
remove his second. It was determined that Commissioner Jones' withdrawal did not require
Commissioner Swift to withdraw his motion to be valid.
Commissioner Byerly moved to deny the zoning change. Commissioner Swift
seconded the motion. The vote being:
Ayes: Swift, Byerly
Noes: Kelly, Sellers, Jones, Wall
[Note: The motion to deny was not approved.]
Commissioner Sellers moved to table the case until the April 14, 2003, meeting.
Commissioner Jones seconded the motion. The vote being:
Ayes: Kelly, Sellers, Jones, Wall
Noes: Swift, Byerly
3. Case Z-03-007 - PUBLIC HEARING - Special Use Permit for an accessory building on
10.272 acres located at 816 L.D. Lockett Road
Clayton Husband presented the case to the commissioners and reviewed the staff briefing.
Chairman Wall asked staff how often a building that requires a special use permit is built
without a permit. Staff responded that a building this size being built without a permit is
unusual. He said the City's recourse is to require the owner to apply for a special use permit
and go through the process of public hearings and if the special use permit is not granted, they
would have to comply with the size regulations in the Land Development Code.
Chairman Wall opened the public hearing. Those present wishing to speak were:
Planning & Zoning Commission
Minutes - March 24, 2003
Page 4 of 8
Approved on Apri/14, 2003
Marty Stajduhar, 101 Williamsburg Court, the applicant. He said he bought the land for the
sole purpose of having horses and growing coastal hay so that he could get an agricultural tax
exemption. Mr. Stajduhar said he used a contractor from Alvarado to build a covered area so
that the horses could be ridden in all types of weather. He said the contractor informed him
that a permit was not needed because the land was agricultural and used for agricultural
purposes.
Mr. Stajduhar apologized that he never talked to staff to confirm the information provided by
the contractor. He said the information provided by the contractor made sense to him because
of the lay of the land and the adjoining properties. He said there was a dilapidated house on
the property that they tore down, but they left the pump room and have considered building a
house on the property and living on the land in the future. He said there was no malicious
intent, only misunderstanding.
Commissioner Sellers asked Mr. Stajduhar about the covered arena. He responded that they
now have loafing shed stalls and they want a closed area for the tractor and equipment. He
said there is a 10' x 10' stone building that may be removed, and the structure that was built
was not prefabricated.
Lorraine Gohr, 809 Lavaca Trail, spoke in favor of the special use permit. She said since the
Stajduhar's have purchased the property, they have cleaned up the property, have put in very
safe fencing, and take excellent care of the property. She said they provide a facility that
handicapped riders can use, and neighbors help with that endeavor. She said the Stajduhar's
and the riding arena are an asset to the community and she wants the rural look to be
maintained in the immediate area. She spoke about the enclave of rural uses that currently
exist on Lavaca Trail and in the immediate area.
Chairman Wall asked Ms. Gohr about the resale potential of her property because of the
impact the size of this building has on her property. She responded that the area is clean and
provides a wonderful service to the community and has no negative impact on her property,
but only enhances the value of the neighborhood.
Commissioner Kelly shared appreciation of the rural area of the neighborhood.
Marty Gohr, 809 Lavaca Trail, spoke in favor of the special use permit. He said he is
concerned about the higher density residential that is encroaching into this very special area of
Coileyville. He said there are several nice properties in the area and they are diminishing
because of the approval of recent higher density subdivisions like Westgate Villas. Mr. Gohr
said the current use and the future intent by the Stajduhar's fit with the neighborhood.
Andrew Mittag, 901 W. Lavaca Trail, spoke in favor of the special use permit. He said he has
spoken before the commissioners on several occasions and they may have heard before how
he moved from New York to Kansas and has now found the oasis in Colleyville on Lavaca
Trail. He expressed the need to keep the area rural and how the frontage on Precinct Line will
be developed as commercial, but the interior of the area needs to be maintained as rural. Mr.
Mittag said he has three horses on his property and this structure does not bother him one bit.
He said the Stajduhar's are an asset to the community.
Planning & Zoning Commission
Minutes - March 24, 2003
Page 5 of 8
Approved on Apri/14, 2003
Chairman Wall asked the Stajduhar's if the property is being used as a commercial venture.
Mr. Stajduhar said no. He stated he operates a physical therapy clinic in Bedford, and his wife
Lisa is certified to use horses as vehicles to help disabled people gain mobility. He said their
family and the neighbors ride horses on the property and they have gate openings to the
neighbor's property.
There being no one else present wishing to speak, the public hearing was closed.
Commissioner Swift told Mr. Stajduhar that he made a very good presentation and he now
understands the request. He said the accessory building conforms to the area.
Commissioner Sellers moved to approve the special use permit with a condition that the
10' x 10' rock building be removed in order to reduce the number of accessory buildings
on the property. Commissioner Kelly seconded the motion.
Commissioner Byerly said he does not have a problem with the motion but asked staff if they
could put a provision in the ordinance that the removal of the building be given a deadline such
as 45 days.
Fire Marshal Jeff Jones said that technically a building of this size should have a fire sprinkler
system. He said if the building is ever enclosed it would create a problem. Chairman Wall
asked what other safety concerns the Fire Marshall had, especially if there were physically
impaired people on the property. Jeff Jones responded that the building is all right if it is used
as intended and as stated in the ordinance. He said if a building permit were ever applied for,
they would reassess the use at that time.
Chairman Wall expressed concerns about potential commercial uses on the property. Staff
told the commissioners that commercial uses are not allowed unless authorized by the Land
Development Code. Staff advised the use of the property is for riding horses, and the only
issue the commissioners are considering is for the building proposed in the special use permit.
Chairman Wall called for the vote. The vote being:
Ayes: Kelly, Swift, Byerly, Sellers, Jones, Wall
Noes: None
4. Case Z-03-008 - PUBLIC HEARING - Zoning Change from CC2 to PUD-R, 9.285 acres
located on the south side of Centerpark, east of Colleyville Boulevard
This item was tabled by the Commission earlier in the meeting.
Planning & Zoning Commission
Minutes - March 24, 2003
Page 6 of 8
Approved on Apri/14, 2003
5. Case Z-03-009 - PUBLIC HEARING - Amendment to the Land Development Code
regarding notification requirements for Special Use Permits for alcoholic beverages
Barry LeBaron presented the case to the commissioners and reviewed the staff briefing.
There were questions by the commissioners regarding the current notice procedure and the
proposed change.
Commissioner Kelly said that if the 500-foot notification area was used, it might impede
upscale restaurants from coming to Colleyville. He said there might be a red flag raised since
no other communities in the area have this requirement.
Chairman Wall opened the public hearing, and those present wishing to speak were:
Jo Ann Gasper, 4103 Paddington Lane, spoke in opposition of the change in notification area.
She said city staff does an excellent job of notification with the use of signs, notice to property
owners, newspaper articles, and notice to homeowner associations. She said if they start with
this exception, there might be other exceptions to follow. She said Colleyville needs to be on a
level playing field with other communities in the area in order to attract businesses. She
explained how the distance requirement was changed to comply with the State law in order to
attract restaurants to Colleyville. Ms. Gasper encouraged the commissioners to recommend
denial of the change.
There being no one else present wishing to speak, the public hearing was closed.
Commissioner Kelly moved to recommend denial of the change to the notification
requirements for special use permits for alcoholic beverages. Commissioner Sellers
seconded the motion. The vote being:
Ayes: Kelly, Swift, Byerly, Sellers, Jones, Wall
Noes: None
6. Discussion of the Master Plan Update.
Appreciation to Barry LeBaron was expressed by the commissioners for all of his work that has
been done.
7. Staff Comments, Reports and Discussion Items: None.
8. Commissioners' Comments and Reports:
The commissioners asked for an update on the status of Bob Culley's request to be reinstated
to the Planning and Zoning Commission. Staff informed them that Mr. Culley was asked to
submit his application for appointment along with the others that would be considered by the
City Council at the April 1 ,2003 meeting. He said advertisements for the opening had already
taken place before Mr. Culley requested to be reinstated.
Planning & Zoning Commission
Minutes - March 24, 2003
Page 7 of 8
Approved on Apri/14, 2003
ADJOURNMENT
The Commission moved to adjourn the meeting at 8:50 p.m. The motion was seconded
and passed by acclamation.
Respectfully Submitted,
~~
~n~ing & Zoning Assistant
Approved on:
Note: As a matter of public record, an audio recording of this Planning and Zoning Commission meeting is
available upon request.
Planning & Zoning Commission
Minutes - March 24, 2003
Page 8 of 8
Approved on Apri/14, 2003
cc.~
Texas
PLANNING AND ZONING COMMISSION
MEETING MINUTES - April 14, 2003
CALL TO ORDER
Chairman Wall called the meeting to order at 7:00 p.m.
ROLL CALL
Commissioners Bruce Kelly, Earl Swift, Jeff Byerly, Mark
Jones, and Jeff Wall were present.
Commissioner Bud Sellers was absent.
Barry LeBaron, Clayton Husband, Jeff Jones, and Jan Levy
from staff were present.
INVOCATION
The invocation was given by Commissioner Swift
PLEDGE OF ALLEGIANCE
APPROVAL OF MINUTES
March 24, 2003
Commissioner Byerly moved to approve the minutes as written. Commissioner Kelly
seconded the motion. The motion passed by unanimous acclamation.
SWEARING IN
Bob Culley was sworn in at Place 5
CITIZEN COMMENTS
There was none.
AGENDA ITEMS
1. Case P-03-009 - Replat of Colleyville Shopping Village Addition, Lots 4R-2-1, 4R-2-2,
4R-2-3, and 4R-2-4 located at 6201 Colleyville Boulevard
Clayton Husband presented the case to the commissioners. Barry LeBaron explained how
commercial lots are not required to have frontage on a public street but are required to provide
access from a dedicated access easement. He said these lots are accessible from a
dedicated easement, which connects to both Colleyville Boulevard and Sanders Lane.
Commissioner Culley moved to approve the minor plat. Commissioner Jones seconded
the motion. The vote being:
Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall
Noes: None
Planning & Zoning Commission
Minutes - April 14, 2003
Page 1 of 8
Approved on April 28, 2003
2. Case Z-03-006 - TABLED ITEM - Zoning Change from CN to PUD-R, 2.05 acres located
at the northeast corner of Cheek Sparger Road and Steeplechase Drive
Commissioner Jones moved to remove the item from the table for discussion.
Commissioner Swift seconded the motion. The vote being:
Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall
Noes: None
Clayton Husband presented the case to the commissioners and reviewed the staff briefing.
There was discussion by staff and the commissioners about the changes in the number of lots,
the size of the lots, the density of the subdivision, and the plans to offer open space that will
help in the realignment of Cheek Sparger Road. Mr. Husband distributed a larger size of the
revised zoning exhibit that reflected the changes. He told the commissioners that a ten foot
(10') wide trail is required along Cheek Sparger Road and the applicant has not asked for a
waiver from the requirement.
Chairman Wall moved to reopen the public hearing. Commissioner Swift seconded the
motion. The motion passed by acclamation.
Those present wishing to speak were:
Jimmy Schnurr, applicant, told about how they took the issues that were problematic to the
surrounding homeowners and redesigned the subdivision by reducing the number of lots, and
adding some open space. He introduced the developer, Monte Thomason.
Monte Thomason, developer, said he met with the Bridlewood Estates Homeowners
Association and addressed the line of sight issue by placing open space along the
southwestern portion of the subdivision. He said the proposed subdivision will have an entry
feature that is compatible with Bridlewood Estates, they reduced the number of lots 20% from
10 lots to 8 and now offer approximately four dwelling units per acre. He said they redesigned
the subdivision so that the smaller lots would abut the commercially zoned property to the east
and the largest lots would abut the residential lots to the north. He said they now have a 45%
reduction in paved area and they will limit the houses along Steeplechase and the two northern
lots to one story and there will be three lots along the eastern side of the subdivision that will
be allowed to have 1 % story homes. Mr. Thomason said they will exceed the Bridlewood deed
restrictions and they will require 95% masonry coverage and no front-entry garages. He said
there will be a HOA that will maintain all grass and landscaping and he plans on planting 15' to
17' live oak trees along Steeplechase to the west of the subdivision and they agree to the
construction of a ten foot trail that is required along Cheek Sparger Road. He said they
contacted Woodbriar Estates, The Woods of Colleyville, and the Saddlebrook homeowners
associations to inform them of the proposed changes.
Planning & Zoning Commission
Minutes - April 14, 2003
Page 2 of 8
Approved on April 28, 2003
Commissioner Swift asked staff about the zoning and use of the lots to the east. There was
discussion about the use of the property along Cheek Sparger. Commissioner Swift asked the
fire marshal if he was all right with the reduction of paved area in the subdivision and Fire
Marshal Jones responded that he did not have any problems with it and it is adequate for that
length of street.
Tom Caunitz, 4006 Steeplechase Drive, represented the Homeowners Association for
Bridlewood Estates and said they met with the developer at the annual HOA meeting. He said
they liked the changes and there are tremendous selling points. He said everyone at the
meeting is in favor of a residential use for the property and the developer has worked with
them to provide landscaping along Steeplechase.
Pam Brandon, 3608 Briarwick Court, said she is president of the Woodbriar HOA and is in
favor of the changes made by the developer. She said she spoke to four out of the six
residents who live along Cheek Sparger Road as they would be most impacted by the
development. She said they were in favor.
D. J. Garmon, 3720 Oakbriar, said he was very concerned about traffic. He reported that
people use Woodbriar Estates as a cut-through and they don't obey the speed limits or stop
signs. He said he doesn't agree there would be more traffic generated by a commercial use
than a residential development on the property. He said the density is still too high and
Bridlewood Estates and the Woods at Colleyville were required to provide 20% open space.
Steve Knight, 3917 Felps Court, spoke in opposition. He explained where he lived in
relationship to the zoning change request. He said that density is a problem and sited the
Sparger/Felps Addition as setting a trend in the area. He told the commissioners that
Bridlewood's higher density was a result of the land being originally zoned multi-family and the
desire of the citizens to have single family homes on the property rather than multi-family. He
encouraged the commissioners to not keep scaling down the size of lots in Colleyville. He
agreed that residential is the best use of the land, but still believes there is crunch room and
the lots could be larger and fewer.
There was no one else present to speak, and Chairman Wall closed the public hearing.
Commissioner Jones moved to deny the zoning change as proposed. Commissioner
Swift seconded the motion.
There was discussion by the commissioners following the motion. Commissioner Culley said
he agrees with the denial and the development needs more green belt and also density is an
issue because the lots are significantly smaller than Bridlewood. Commissioner Byerly spoke
about the need to jealously guard the adjoining commercial space and take a wait and see
position in case commercial can develop in the area. Commissioner Kelly said even the
representatives from Bridlewood supported reducing the density in order to have residential
development on that property.
Planning & Zoning Commission
Minutes - April 14, 2003
Page 3 of 8
Approved on April 28, 2003
Chairman Wall called for the vote. The vote to deny being:
Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall
Noes: None
Chairman Wall explained that the case can go to City Council for consideration; however it will
require a super majority approval vote to grant the zoning change request.
3. Case Z-03-008 - PUBLIC HEARING & TABLED ITEM - Zoning Change from CC2 to PUD-R,
9.285 acres located on the south side of Centerpark, east of Colleyville Boulevard
Clayton Husband presented the case to the commissioners and reviewed the staff briefing. He
told the commissioners that the applicant and representative are in attendance to make a
presentation. Clayton said staff received two letters of opposition and they are in the
commissioners' packets.
Commissioner Jones moved to remove the item from the table. Commissioner Kelly
seconded the motion. The vote being:
Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall
Noes: None
Kennis Ketchum, Portfolio Development, was present to represent the case. She spoke about
the need for senior housing and presented statistics supporting her position. She said the
buildings would have direct access garages and when they designed the architectural style,
they were sensitive to what Colleyville is about and they didn't want to insult the community.
Kennis said they will limit the buildings to one story where the buildings abut current residential
and will and can legally restrict the rentals to seniors. She said the rents will be between $800
to $1,500 per month.
Greg Faulkner, architect, also representing the land owner, showed slides of other similar
projects that were developed in Dallas and other parts of the country. He explained the
concept and how they try to keep the scale and luxury of single family homes and told about
other amenities. Mr. Faulkner said there will be kitchen islands in some units and walk in
closets. He said the streets will have names to give a sense of a single family development.
He said there will be approximately 142 units and there will be entries off Centerpark and
Colleyville Boulevard. He said that all cars will be required to be parked in garages; however
they will provide guest parking.
Commissioner Swift asked questions about the comparison of the proposed Colleyville project
to the Hilton Head project that Mr. Faulkner's company designed. Mr. Faulkner said that the
project was built in 1997 to 1998 and the projects would be similar in construction costs, but
Planning & Zoning Commission
Minutes - April 14, 2003
Page 4 of 8
Approved on April 28, 2003
the Hilton Head project would demand a higher rental cost, and the Hilton Head project was
exclusively rentals.
Commissioner Culley commented that the fronts of the buildings in the Colleyville design lack
brick and masonry.
Commissioner Jones questioned the marketing and research study that was performed and
asked what brought the developer to Colleyville. Mr. Faulkner and Kennis Ketchum said that
the owner has had no good commercial offers on the property and they felt there was a need
to propose something different so that the property could be developed. There was discussion
about why the developer is proposing rentals vs. sales.
Mark Hiller, 6615 Brookshire, Dallas, Texas, owner of the property, said that Colleyville has a
situation where parents are living with children and he felt there is a definite need for this kind
of project for Colleyville residents. He said that he is not married to an apartment concept and
would take the comments offered by the commissioners and consider condominiums.
Commissioner Jones asked if the market study indicated that rents are more desirable than
condominium ownership. Mr. Hiller responded that according to the economic part of the
issue, rentals would be the first choice, but condominiums would not prohibit his interest in the
development of the land.
Andrew Wayne, 1009 Lakeridge, commented that the developer made a good presentation
and said he is 57 years old and there is a need in Colleyville for senior citizen housing;
however, the commissioners denial of the previous case because of density issues, negates
approval of this item because it has an even higher density. He said there is a need for
housing for seniors in Colleyville, but not a need for this type of living quarters. He said that
this is not a marketing study provided by the applicant, but a professional study. He said there
is very little greenbelt associated with the development and adding a minimum of 100 cars to
Centerpark will affect all who live in the area. He said he is opposed to the zoning change.
Dr. Susan Hess, 4609 Westbury Drive, said she lives in the Lakes of Somerset subdivision and
has concerns that this development does not fit the ambiance of the area. She said density,
and traffic concerns are a huge issue and there are better uses for the property.
Don Shaver, 1001 Edgewater, said reports by City Council have stated that there are 57
seniors in Colleyville and he supposed those 57 seniors would not downsize to a two story
apartment. He said nice garden homes with a lower density should be considered for the
property.
Ken Wallace, 4205 Green Meadow East, said he is in total opposition of the proposed zoning
change. He said there should be no two story structures and has fears that in the future the
property would not be maintained and it's value would decline. He said this may be a good
concept, but not for where it is proposed.
Larry Henry, 4104 Inwood Lane, said he is a 15 year Colleyville resident, and there is a need
for more commercial tax producing businesses. He said this proposal is too disparate from the
Planning & Zoning Commission
Minutes - April 14, 2003
Page 5 of 8
Approved on April 28, 2003
Master Plan and the commissioners need to take time and understand the impact this proposal
will have on the area.
Margaret Sherlock, 905 Briar Ridge, said the City already has an apartment/town home project
that was built by a Dallas developer who built two story buildings with the master bedroom
upstairs and that was not a successful project. She spoke in opposition.
Phil Charon, 4604 Clearwater Court, said his property abuts the east property line of the
proposed project. He said that two story apartments are not designed for seniors. He said the
developer has stated he proposes luxury apartments and when he compared rates along
Highway 121, the average rental is $1.00 per square foot average. He said this proposed
project is not a luxury apartment, but compares with average apartment rentals. He said that
even though one story apartments are being proposed along the eastern property line, the
finish floor elevations will rise to the west toward the flood plain and those buildings will
overlook his property. He spoke about density and traffic problems and said this proposal is
not suitable for Colleyville.
Steve Ewing, 700 Green Meadow North, said he was on the Board of Directors of Saddlebrook
HOA. He spoke in opposition due to density and the negative impact it would have on home
values in the area.
Ron Grove, 4708 Lakeshore Court, said there are so many boarded up businesses along
Highway 26 and the addition of this type of project will degrade property values.
Alan Jackson, 4801 Lakeshore Court, said most elderly people do not live in apartments. He
said he pays three times the amount of taxes as in Keller, but does so willingly in order to live
in a community that does not have these kinds of projects. He spoke about the negative
impact the additional traffic and high density have and stated there is a place for this kind of
product, but not here.
Jim Gormley, 502 Green Meadow North, spoke in opposition sighting high density, lack of
open areas and lack of green belts. He said Centerpark access is an issue as is the risk of
seniors accessing off Colleyville Blvd. He said patio homes would be a great alternative with
fewer units and one story buildings.
Brad Trow, 4605 Colleyville Boulevard, said he owns the property where Riceland is located.
He said although he relishes the idea of having so many hungry people nearby to support the
restaurant trade, the property will become more desirable for commercial development when
Highway 26 is widened.
Kennis Ketchum, applicant, said that they appreciate all of the comments, and they are trying
to come up with the highest and best use of the property. She said the owner has not been
able to sell as commercial and they are proposing an alternative use.
Chairman Wall closed the public hearing.
Commissioner Culley commented that it appears the developer is here to make changes and
work with the neighbors and he has never heard such productive comments at a public hearing
Planning & Zoning Commission
Minutes - April 14, 2003
Page 6 of 8
Approved on April 28, 2003
before. He said that Centerpark can handle more traffic and it can be regulated as the
outgoing traffic from the day care center is regulated. He said that density is an important
issue and apartments are not needed at this time in Colleyville.
Commissioner Swift said that he is qualified to speak as a senior citizen. He spoke about
current problems with a similar project, Spring Garden. He said that apartments don't fit the
long term image of Colleyville and are counterproductive. He said he was very impressed with
the image of Lakewood Estates and is sensitive to their comments. He said he did not believe
it was legal to restrict rentals by age.
Commissioner Kelly said that the comments by the citizens are not against development and
growth in the area, but are against this type of proposal. He said it seemed as if the citizens
and developer still want something to happen on the property.
Commissioner Jones moved to deny the zoning change request. Commissioner Culley
seconded the motion. The vote being:
Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall
Noes: None
Chairman Wall encouraged citizens to get involved with the Master Plan Update process. He
said it seems as if the developer is willing to work with the community.
[NOTE: The Planning and Zoning Commission took a 5 minute break and then resumed the
meeting.]
4. Discussion of the Master Plan Update:
Barry LeBaron said he is pleased with the positive feedback he has received regarding the
meetings. He went over the upcoming schedule and outlined the process once the
neighborhood meetings are concluded.
Chairman Wall asked the commissioners to check their June and July schedules and notify
staff so that meetings can be scheduled when most members can be present.
There was discussion about comments raised in a Master Plan neighborhood meeting about
the City pooling resources with the GCISD.
Chairman Wall requested that staff meet with the new City Council and Mayor to update them
on the Master Plan process with the Planning and Zoning Commission present.
5. Staff Comments, Reports and Discussion Items: There were none.
Planning & Zoning Commission
Minutes - April 14, 2003
Page 7 of 8
Approved on April 28, 2003
6. Commissioners' Comments and Reports: There were none.
ADJOURNMENT
The Commission moved to adjourn the meeting at 8:55 p.m. The motion was seconded
and passed by acclamation.
Respectfully Submitted,
an Levy
Planning & Zoning Assistant
Approved on: April 28, 2003 as written.
Note: As a matter of public record, an audio recording of this Planning and Zoning Commission meeting is
available upon request.
Planning & Zoning Commission
Minutes - April 14, 2003
Page 8 of 8
Approved on April 28, 2003
COLLEYVILLE LIBRARY BOARD MINUTES
March 10, 2003
I. CALL TO ORDER - The meeting of the Colleyville Library Board was called
to order at 7:07 p.m.
ROLL CALL - Members present: Chair Gary Taraba, Vice Chair Carol Wollin,
Pat Jones, Richard Roxburgh, Susan Barzelay, Mary Alice Rippe, Mary Ann
Nicholson and Nancy Eytcheson
Ex-Officio Members present: Mayor Donna Arp
Ex-Officio Members absent: Dr. Kevin Singer, Dr. Larry Darlage, Steve
Jacobs, Ret Stansberger and Steve Banta.
Council Liaisons present: Mayor Pro Tem Ginny Tigue.
Staff present: Dianne McWethy, Mary Rodne and Cindy Martin.
II. ANNOUNCEMENTS
Chair Gary Taraba read Caren Handleman's letter of resignation into the
record. Staff gave an overview of the process of filling the vacant position.
III. INTRODUCTION OF LIBRARY DIRECTOR MARY RODNE
Chair Gary Taraba welcomed Library Director Mary Rodne on behalf of the
Board.
IV. APPROVAL OF THE FEBRUARY 10, 2003 MINUTES - A motion was made
by Pat Jones, seconded by Susan Barzelay to approve the February 10,
2003 minutes, as corrected.
V. Development of Policies and Procedures
a. Exhibits and Displays
b. Confidentiality
c. Bulletin Boards & Handouts
d. Study Room Use
e. Computer Use
f. Other
There was a general discussion regarding these policies. Director Mary
Rodne will present policies at the next Board meeting.
VI. DISCUSSION AND CONSIDERATION OF THE COLLEYVILLE ROTARY
CLUB ANNUAL EVENT
There was a general discussion regarding the event. The Board decided to
refer the Rotary Club to the Friends of the Library and the Library Foundation
for further discussion.
VII. CITY HALL AND LIBRARY CONUSTRUCTION UPDATE
Staff gave an overview of the City Hall and Library construction project.
VIII. FRIENDS OF THE COLLEYVILLE PUBLIC LIBRARY UPDATE
Carol Wollin President of the Friends of the Colleyville Public Library gave an
update of the Friends of Library scheduled events and a grant the Friends
received from Verizon.
IX. COLLEYVILLE PUBLIC LIBRARY FOUNDATION UPDATE
Mayor Pro Tem Ginny Tigue gave an overview of the Colleyville Public Library
Foundation's activities.
X. SUGGESTED ITEMS FOR FUTURE MEETINGS
The Board requested that a tour of the Library construction site be added to
the next agenda.
XI. ADJOURN: A motion was made by Mary Ann Nicholson, seconded by
Nancy Eytcheson to adjourn the meeting. Motion approved. The meeting of
the Colleyville Library Board was adjourned at 8:25 p.m.
COLLEYVILLE HISTORICAL PRESERVATION COMMITTEE
Minutes - March 11,2003
I. Call To Order - The meeting of the Colleyville Historical Preservation Committee was
called to order at 7:05 pm.
Roll Call- Members present: Chairman Joe Deupree, Sammie Bolling, Lila Coley, Nicky
Fettig, Ed Havran, and Shirley Schollmeyer. Members absent: Gerald Hartman, Jr.,
Molly Munson, Mike Patterson, and Betty Jean Willbanks.
Also present were Deputy City Manager Dianne McWethy, Parks and Recreation
Manager Monica Walsh, Mayor Pro Tern Ginny Tigue and Mayor Donna Arp.
II. Approval of Minutes of February 11, 2003 - Ed Havran made a motion, second by Lila
Coley, to approve the minutes of the meeting of February 11,2003. Motion approved.
III. Presentation By Larry Crowder for Historical Public Art - Mr. Crowder, known for
his bronze sculptures, presented to the Committee the following proposal for a bronze
bust of Dr. Colley to be placed in front of City Hall:
BUST - $8500.00 (113 WHEN COMMISSION IS GRANTED, 1/3 WHEN CLAY IS
APPROVED, 1/3 ON DELIVERY) Price does not include pedestal.
IV. Presentation by Brenda Mohle, Signet Art, Owner/Art Consultant, for Texas Bank
Historical Photographs - Ms. Mohle discussed the Texas Bank project currently under
construction on Colleyville Blvd. She stated that Texas Bank is the oldest, Texas owned
bank and specializes in banks in small communities. She is requesting that the Committee
help with the project of locating historical photographs that she can use for decorating the
new Texas Bank.
V. Discussion of Webb House National and State Historical Marker - Colleyville Parks
and Recreation Manager Monica Walsh presented the Committee with information and
guidelines required to apply for County, National and State Historical markers for the
Webb House.
Joe Deupree reported that the Grapevine Historical Society requested permission to have
an outdoor meeting in the park at the Webb House in September.
VI. Discussion and Consideration of Approval of Local Historical Marker Application
for the Fire Station/City Hall - A motion was made by Lila Coley, second by Ed
Havran, to approve and send to the City Council the application for a local historical
marker to be placed at Texas Bank. Motion approved.
VII. Update of Local Historical Marker Applications - Ed Havran reported that he has
completed the research and is working on the application for a marker to be placed at the
Bogart Dairy site located at Colleyville Blvd. and Hall Johnson Rd., currently the Town
Center site.
VIII. Update of Historical Preservation Foundation - Shirley Schollmeyer reported that she
has been working with Administrative Assistant Cindy Martin and plans to have the
required paperwork to present at the next meeting.
IX. Discussion and Consideration of Historical Information for the Colleyville Website -
No report
XI. Discussion of City of Colleyville 50th Year Anniversary Event - No report
Due to the lack of a quorum, the meeting was recessed at 9: 15 pm.
XI. Adjourn - Meeting adjourned at 9: 15 pm. The next regular scheduled meeting will be
April 8, 2003, at 7:00 pm.
ZONING BOARD OF ADJUSTMENT
MINUTES OF MEETING - MARCH 25, 2003
REGULAR MEETING: Chairman McNosky called the regularly scheduled meeting to order at
7:00 p.m. on March 25, 2003.
Roll Call
Present:
Rich Munson, Skip Reynolds, Butch Bercher, Larry
Henry, Dee McNosky, Ron Sturgeon, Pat Davis
Staff: Tom Niederauer, Jan Levy, Eddie Edwards
Approval of Minutes
March 11, 2003
Butch Bercher moved to approve the minutes. Larry Henry seconded the motion. The
motion was passed by a unanimous vote.
Chairman McNosky explained the procedures of the Zoning Board of Adjustment and outlined the
meeting format for the audience. She explained that approval of a variance requires four (out of
five) affirmative votes by members of the Board. The five voting members were: Rich Munson,
Skip Reynolds, Butch Bercher, Dee McNosky, and Larry Henry; however, the alternate members
may enter into the full discussion of the case.
AQenda Items
Case A-03-003 - PUBLIC HEARING. Request by Larry Cole, Foxcreek Residential
Development, I nc. for a variance from the fence setback regulations of the Colleyville Land
Development Code at 401 Vintage Court, Lot 17, Block 5, Remington Park Addition, Phase III
Tom Niederauer presented the case to the Board and reviewed the staff briefing. He displayed
overheads of the location of the property, the site plan, and pictures of the property and
surrounding areas. He said there was one letter of opposition included in their packets; however,
three additional letters of opposition were received the afternoon of the meeting and copies of
those letters have been made and distributed to the Board members and the applicant.
There was a question about the location of the driveway on the adjacent lot at 6104 Remington
Parkway. Staff informed the Board and showed a picture to indicate the driveway was located at
the far end of the lot and was not immediately adjacent to the lot at 401 Vintage Court.
Chairman McNosky opened the public hearing portion of the meeting. Those present wishing to
speak were:
Larry Cole, applicant, presented the case to the Board. He said he is the developer of Remington
Park and also acts as the Chairman of the Architectural Control Board for the subdivision. He
Zoning Board of Adjustment
Minutes - March 25, 2003
Page 1 of 3
Approved on April 8, 2003
explained how this was a very unusually shaped lot that is impacted by having street setbacks on
three sides and the owner, Peter Dibella, wanted to achieve some privacy in the back yard. He
said seven of the eight board members on the Architectural Control Board viewed the plans and
had no objections. He said they determined there would be no obstruction of view on the street
and the aesthetics of the proposal was very important to the subdivision as a whole. He said the
good side of the fence will face out and the Architectural Control Board agreed that they didn't
want to look into the Dibellas' back yard. He said that Peter Dibella is a landscaper and what he
will provide for landscaping will be very attractive and well maintained.
Mr. Cole told the Zoning Board of Adjustment members that no neighbors spoke with him, as the
developer of Remington Park, or the home owner, so they were surprised by the opposition and
have not had time to talk with the neighbors who expressed opposition in writing, and did not
attend the meeting to openly discuss their concerns.
Pete Dibella, 401 Vintage Court, said there is a beautiful mature live oak tree on the lot closer to
Vintage Court and they wanted to preserve the tree for the neighborhood. He said that is why
they positioned their home as they did on the lot and they needed to build a home that is in the
same style and size for the subdivision. He said they would like to build a pool off the patio as
others have done in the neighborhood. Mr. Dibella said he will provide landscaping that benefits
the neighborhood and he is open to adjusting the setback a little to provide for the landscaping.
He said maintenance will not be a problem since he is in the business.
Ron Sturgeon asked Mr. Dibella if he met with his neighbors, could a compromise be reached?
Butch Bercher said there was a compromise offered in the packet with the possibility of using a
wrought iron fence. Mr. Dibella said that privacy is an issue and the growth ofthe landscaping will
not mature until three to four years to provide privacy. He said he has three children and it is very
important to him that they have a fenced area to play in that is not visible from the street.
Ron Sturgeon asked the applicant if he could split the difference from the setback he is asking for
and the required setback and build the fence in that location.
Larry Henry said there is possibility of the Board not granting a variance and before they get into
negotiating a different setback for the fence, the Board needs to discuss the merits of the case.
Larry Cole stated that originally he felt the less ground to be maintained outside the fence, the
better it will be maintained.
There was no one else present wishing to speak, and Chairman McNosky closed the public
hearing portion of the meeting.
Rich Munson said he drove around Remington Park and thought this was the only site where a
solid fence would be adjacent to the sidewalk. He said the elevation of the street across from the
fence, Chestnut Bend, would allow people coming off that street to have a clear view into the
Dibellas' back yard. He said he saw another lot with a wrought iron fence around the pool, and he
is not inclined to agree with a solid fence built in that area.
Larry Henry said the Board needs to deal with the ordinances and constraints they are to work
within. He said a wrought iron fence with shrubs as proposed by the letter writer does not present
Zoning Board of Adjustment
Minutes - March 25, 2003
Page 2 of 3
Approved on April 8, 2003
a good argument for the safety issue. He said when the shrubs fill in, there will be a solid barrier
and that will be no difference than a wooden fence.
Butch Bercher said the applicant did not receive the letters of opposition until just prior to the
meeting and that puts the applicant and the board at a disadvantage because the neighbors did
not appear at the meeting.
Skip Reynolds said it is significant that the applicant has requested the Board to table the case,
but the next time they appear before the Board he wants more information. He said he is troubled
with the fencing issues because facing the house the way the applicant has, it disturbs the
neighbors. He said there are three issues that are of importance and they are the safety issues,
the aesthetics and property values of the neighborhood. He said there have been occasions and
it is helpful if an applicant proposes a compromise plan such as a Plan A and a Plan B to the
Board. He encouraged the applicant to look at other types of fences that would be appealing to
the neighbors.
Skip Reynolds moved to table the case until the April 8, 2003 meeting. Butch Bercher
seconded the motion. Skip Reynolds amended his motion to include that the case may be
tabled up to thirty days if necessary and the applicant will contact the City staff and advise
them of the status of the request. Rich Munson seconded the amendment. The vote being:
Ayes: Munson, Reynolds, Bercher, Henry, McNosky
Noes: None
ADJOURNMENT
The meeting was adjourned by acclamation. They're being no further business, the meeting
adjourned at 8:00 p.m.
Respectfully Submitted,
Jan Levy, Planning & Zoning Assistant
Approved on: April 8, 2003 as written.
Zoning Board of Adjustment
Minutes - March 25, 2003
Page 3 of 3
Approved on April 8, 2003
RESOLUTION R-03-2146
A RESOLUTION APPROVING COUNCIL ACTION
UNDER BUSINESS AT THE REGULAR
COUNCIL MEETING OF
MAY 6, 2003
WHEREAS, Council has taken action on certain items on the agenda under Business.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
COLLEYVILLE, TEXAS:
Sec. 1.
THAT the agenda decisions approved by Council action under Business
this date and not otherwise adopted by Ordinance and/or separate
Resolution as follows are hereby adopted:
a.
THAT
AND IT IS SO RESOLVED.
APPROVED THIS DAY OF
_ AYES, NAYS AND ABSTENTIONS.
2003, BY A VOTE OF
ATTEST:
CITY OF COLLEYVILLE:
Cynthia Singleton, TRMC
City Secretary
Mayor