Loading...
HomeMy WebLinkAboutCity Council-Agenda Packets-5/6/2003 City of Texas AGENDA CITY COUNCIL MEETING 5400 BRANSFORD ROAD MAY 6, 2003 5:15 P.M. - PRE-COUNCIL AGENDA PC- 1. Discussion of May 6, 2003 City Council regular agenda items REGULAR AGENDA 6:45 P.M. - CALL TO ORDER ROLL CALL 1. EXECUTIVE SESSION - In accordance with Texas Government Code Chapter 551 , Subchapter D Sec. 551.071 - Consultation with Attorney on Legal Issues Raised by Public Hearing or Action Items on the Agenda Legal - Potential Litigation - Explorer Pipeline Sec. 551.071 - 7:30 P.M. - RESUME REGULAR MEETING INVOCATION: Pastor Timothy Perkins, Crown of Life Lutheran Church PLEDGE OF ALLEGIANCE: Ross Foster, City Attorney P.O. BOX 185 COLLEYVILLE, TEXAS 76034 (817) 577-7575 2. READING AND PUBLIC HEARING - Resolution R-03-2141 - Canvassing the General City Council Election for Mayor and Places 1 and 2 and Special Election To Fill An Unexpired Term, Council member, Place 4, held May 3, 2003 3. OATHS OF OFFICE - MAYOR AND COUNCILMEMBERS, PLACES 1, 2 and 4 4. RECEPTION FOR MAYOR AND COUNCILMEMBERS 5. ELECTION OF MAYOR PRO TEM 6. CORRESPONDENCE, MISCELLANEOUS REPORTS OF MEETINGS ATTENDED BY THE COUNCIL AND CITY OFFICIALS, AND ANNOUNCEMENTS, PROCLAMATIONS, OR PRESENTATIONS PROCLAMATION - In recognition of National Police Week, May 10 -18, 2003 - Police Chief John Young and Officer Bill Hudgins PRESENTATION - Plaques will be presented to Mayor Donna Arp and Councilmembers Joe Hocutt and Jim Moore CONSENT: 7. READING AND PUBLIC HEARING - Resolution R-03-2142 - Consent Items: a. Approval of minutes of the regular City Council meeting of April 15, 2003 b. Approval of minutes of the City Council Worksession of March 26, 2003 c. Approval of the recommendation of the Sign Board of Appeals for a variance to allow a 6' tall by 11' wide by 22" deep sign at the entrance of Good Shepherd Catholic Community on Tinker Road with the requirement that the light be turned off at 10:00 p.m. and allow the existing signs to remain, Case G-03-007 d. Approval of the recommendation of the Sign Board of Appeals for a variance to allow a 5' by 10' changeable letter marquee wall mounted sign above the steps on the eastern side of the Sunbelt Gymnastics building located at 4701 Bransford Road, Case G-03-008 PUBLIC HEARINGS: 8. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1403 - Approval of Amendments to Chapter 14 of the Land Development Code regarding drainage, fire lane, construction plans and other engineering requirements, Case G-03-006 9. FIRST READING AND PUBLIC HEARING - Ordinance 0-03-1404 - Approval to amend Ordinance 092-880 establishing the fee structure for the circulation of materials and replacement and processing fees for materials for the Colleyville Public Library 10. READING AND PUBLIC HEARING - Resolution R-03-2143 - Approval to amend Resolution R-02-1925 Authorizing the Approval of the 2001 Drainage Bond Project List 11. READING AND PUBLIC HEARING - Resolution R-03-2144 - Approval of a Construction Contract for Welsh Circle Paving Improvements Project with J.L. Bertram Construction and Engineering, Inc., in the amount of $102,763 12. READING AND PUBLIC HEARING - Resolution R-03-2145 - Approval of an Interlocal Agreement with Tarrant County for Glade Road, Rose Street, Cherry Avenue, Lowrie Road and Reagan Road improvements, in amount not to exceed $65,000 TABLED ITEMS: 13. READING AND PUBLIC HEARING - Resolution R-03-2124 - Approval of a waiver of perimeter street improvement requirements on Lot 3R, Block 2, Thompson Terrace, located at 5009 Thompson Terrace, Case P-02-045 REPORTS: 14. PLANNING AND ZONING COMMISSION MINUTES - March 24, 2003 PLANNING AND ZONING COMMISSION MINUTES - April 14, 2003 COLLEYVILLE LIBRARY BOARD MINUTES - March 10, 2003 HISTORICAL PRESERVATION COMMITTEE MINUTES - March 11,2003 ZONING BOARD OF ADJUSTMENT MINUTES - March 25, 2003 CITIZEN COMMENTS: 15. CITIZEN COMMENTS/PRESENTATIONS REGARDING ITEMS NOT ON THE AGENDA ACTION/RESOLUTION: 16. DISCUSSION AND CONSIDERATION OF A RESOLUTION RATIFYING COUNCIL AGENDA ACTION FOR THE MEETING OF MAY 6, 2003 - Reading and Public Hearing - Resolution R-03-2146 ADJOURNMENT: 17. ADJOURNMENT I hereby certify the above agenda was posted on the bulletin board at City Hall on Friday, May 25, 2003, at 5:00 p.m. . ~ ~ Singleton, TR City Secretary If you plan to attend this public meeting and have a disability that requires special accommodations, please advise the City Secretary at least 48 hours in advance at 817.577.7575, and reasonable accommodations will be made to assist you. PRE-COUNCIL CllY 1)( CG~n1l AGENDA BRIEFING 11..~-"iI$ MEETING DATE: ! 05/06/03 CITY MANAGER ! ~ ITEM#: ' PC-1 DEPARTMENT HEAD f' J~ : FINANCE REVIEW ~ N/A Previous Action: None DEPARTMENT: CITY COUNCIL SUBJECT: Discussion of the May 6, 2003, City Council regular agenda items This item provides the opportunity for the City Council to discuss the May 6, 2003, City Council regular agenda items. CITY COUNCIL Ciryor (Q~n1l AGENDA BRIEFING 1l':\iI$ MEETING DATE: ITEM #: RESOLUTION #: 05/06/03 1 N/A CITY MANAGER DEPARTMENT HEAD FINANCE REVIEW N/A Previous Action: None DEPARTMENT: CITY COUNCIL SUBJECT: Executive Session - In accordance with Texas Government Code Chapter 551, Subchapter D EXECUTIVE SESSION - In accordance with Texas Government Code Chapter 551, Subchapter D Sec. 551 .071 - Consultation with Attorney on Legal Issues Raised by Public Hearing or Action Items on the Agenda Legal - Potential Litigation - Explorer Pipeline Sec. 551.071 - CITY COUNCIL (:,1 Y Of CG~~JTI.1) AGENDA BRIEFING Il,,,,;:\$ MEETING DATE: 05/06/03 CITY MANAGER ITEM#: 2 DEPARTMENT HEAD! RESOLUTION #: R-03-2141 FINANCE REVIEW ! N/A Previous Action: None DEPARTMENT: CITY COUNCIL SUBJECT: Canvassing the General City Council Election for Mayor and Places 1 and 2 and Special Election To Filii An Unexpired Term, Councilmember, Place 4, held May 3, 2003 READING AND PUBLIC HEARING This Resolution provides for the City Council to canvass the results of the May 3, 2003, General City Council Election for Mayor and Places 1 and 2 and Special Election To Fill An Unexpired Term, Councilmember, Place 4, in accordance with Texas Election Code Section 67.004. RESOLUTION R-03-2141 A RESOLUTION CANVASSING THE MAY 3,2003, GENERAL ELECTION FOR MAYOR AND PLACES 1 AND 2 AND SPECIAL ELECTION TO FILL AN UNEXPIRED TERM, PLACE 4 WHEREAS, a General Election was duly held in the City of Colleyville, Texas, on the 3rd day of May 2003, for the purpose of electing a Mayor and Councilmembers 1 and 2; and WHEREAS, a Special Election was duly held in the City of Colleyville, Texas, on the 3rd day of May 2003, for the purpose To Fill An Unexpired Term of Councilmember, Place 4; and WHEREAS, the City Council has met and canvassed the votes cast in such election in accordance with the Texas Election Code, Section 67.004; and, WHEREAS, such canvass showed the following results: MAYOR Mike Taylor Joe Hocutt Richard Newton PLACE 1 Dave Dudziak Mark Skinner PLACE 2 Elaine H. Dolan Brad Rice Resolution R-G3-2141 Page2of2 PLACE 4 Jon Ayers Jerome Davis NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. THAT the canvass is hereby approved. AND IT IS SO RESOLVED. APPROVED THIS DAY OF _ AYES, NAYS AND ABSTENTIONS. 2003, BY A VOTE OF ATTEST: CITY OF COLLEYVILLE: Cynthia Singleton, TRMC City Secretary Donna Arp Mayor CITY COUNCIL ell Y Of ((\J~n,?" AGENDA BRIEFING ~~t ;'"Cd Il';>;;:-l$ MEETING DATE: ITEM#: RESOLUTION #: 05/06/03 3 N/A CITY MANAGER DEPARTMENT HEAD FINANCE REVIEW N/A Previous Action: None DEPARTMENT: CITY COUNCIL SUBJECT: Administration of the Oath of Office to the Mayor and Councilmembers, Places 1 , 2 and 4 City Secretary Cynthia Singleton will administer the Oath of Office to the Mayor and Councilmembers, Places 1, 2 and 4. In the name and by the authority of The State of Texas OATH OF OFFICE I, , do solemnly swear (or affirm), that I will faithfully execute the duties of the office of of the State of Texas, and will to the best of my ability preserve, protect, and defend the Constitution and laws ofthe United States and ofthis State, so help me God. Affiant SWORN TO and subscribed before me by affiant on this day of Signature of Person Administering Oath (Seal) Printed Name Title Form #2204 CITY COUNCIL city Of CG'ii~,n", AGENDA BRIEFING Tl'X,,$ MEETING DATE: ITEM#: ! RESOLUTION #: ! 05/06/03 4 N/A CITY MANAGER j DEPARTMENT HEAD ! FINANCE REVIEW Previous Action: None DEPARTMENT: CITY COUNCIL SUBJECT: Reception for Mayor and Council members Immediately following the Oath of Office, there will be a reception in the Council Chambers honoring the Mayor and Councilmembers. CITY COUNCIL Cily r)( ((\!c5ii~~jm1J AGENDA BRIEFING ~\CI i~':-;0~ MEETING DATE: i ITEM#: ! RESOLUTION #: 05/06/03 5 N/A CITY MANAGER i DEPARTMENT HEAD i FINANCE REVIEW N/A Previous Action: None DEPARTMENT: CITY COUNCIL SUBJECT: Election of Mayor Pro Tem This item is provided in accordance with the City of Colleyville Charter, Section 3.06(B), for the purpose of electing from among the Council, a Mayor Pro Tem who shall serve for the term of one (1) year. l 1 ------- _.~- . ..... C~ARTER ot city Of TexaS DATED: 11/7/95 l_J ilce ~ members to raise the membership to lour (4). These appointees shall serve until the positions can be Iilled at the next regular or special City election. Section 3.06 Mayor and Mayor Pro Tem: A. The Mayor shall preside at all meetings 01 the Council, shall vote only in case 01 a tie vote 01 the Council, and shall have veto power. The Mayor shall sign all contracts and conveyances made or entered into by the City, and all bonds issued under the provision 01 this Charter, and shall be the o"icial representative of the City. The Mayor shall be recognized as the o"icial of the City by the Court for the purpose 01 serving civil process. (Amended April 7, 1984) B. Election of Mayor Pro Tem: Immediately following the final swearing in of all members elected in accordance with Section 4.02 of this Charter, the new Council shall in its first regular meeting, elect from among its members a Mayor Pro Tem who shall serve for the term of one (1) year. (Amended April 7.1984) C. The Mayor Pro Tem shall, in the absence 01 the Mayor, preside at all meetings 01 the Council and shall vote on all issues belore the Council. The Mayor Pro Tem shall have no veto p'ower. but shall per10rm all other duties of the Mayor during the absence or disability 01 the Mayor. (Amended April 7, 1984) D. Emergency Powers of the Mayor: In time of danger or emergency, the Mayor may take command of the Police and govern the City by proclamation and maintain order and enlorce all laws. Section 3.07 Powers 01 the Council: All powers and authority granted to the City by the Conslilution of the State of Texas shall be vested in the Council, except as otherwise provided by law or this Charter. The Council shall provide for the exercise thereof and lor the per10rmance of all duties and obligations imposed upon the City by law and this Charter. Section 3.08 Prohibitions: A. Holding other office: Except where authorized by law, no Mayor or Council Person shall hold any other City o"ice or employment by the City during the term lor which he was elected to the Council, and no former Mayor or Council Person shall hold any compensated appointive City Office or employment until one (1) year alter the expiration 01 the term lor which he was elected. . B. Appointments and/or removals: The members 01 the Council shall in no way dictate the appointment or removal 01 any City administrative ollicer or employee whom the City Manager or any 01 his subordinates are empowered to appoint, unless otherwise provided in this Charter. The Council, by at least lour (4) allirmalive votes, in public session, may require the City Manager to remove any employee for cause. C. Inter1erence with Administration: Except lor the purpose 01 inquiries and investigations by the direction 01 the Council, unless provided otherwise in this Charter, the Council or its members shall deal with City ollicers and employees who are subject to the direction and supervision 01 the City Manager solely through the City Manager, and neither the Council nor its members shall give orders to any such officer or employee, either publicly or privately, except in a state 01 declared emergency. 5 CITY COUNCIL cltr O( caeCll AGENDA BRIEFING it.~;>.:,,::> MEETING DATE: 05/06/03 CITY MANAGER ! , ITEM#: 6 DEPARTMENT HEAD I aP RESOLUTION #: N/A FINANCE REVIEW i N/A Previous Action: None DEPARTMENT: CITY COUNCIL SUBJECT: CORRESPONDENCE, MISCELLANEOUS REPORTS OF MEETINGS ATTENDED BY THE COUNCIL AND CITY OFFICIALS AND ANNOUNCEMENTS, PROCLAMATIONS OR PRESENT A TIONS PROCLAMATION - In recognition of National Police Week, May 10 - 18, 2003 - Police Chief John Young and Officer Bill Hudgins PRESENTATION - Plaques will be presented to Mayor Donna Arp and Councilmembers Joe Hocutt and Jim Moore , ~ 1 . ';g- ~ . ~ j i RESOLUTION R-03-2142 A RESOLUTION APPROVING COUNCIL ACTION UNDER CONSENT ITEMS AT THE REGULAR COUNCIL MEETING OF MAY 6, 2003 WHEREAS, Council has taken action on certain items on the agenda under Consent Items. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. a. THAT the agenda decisions approved by Council action under Consent Items as follows are hereby adopted: THAT the minutes of the regular City Council meeting of April 15, 2003, are hereby approved. b. THAT the minutes of the City Council Worksession of March 26, 2003, are hereby approved. c. THAT the recommendation of the Sign Board of Appeals for a variance to allow a 6' tall by 11' wide by 22' deep sign at the entrance of Good Shepherd Catholic Community on Tinker Road with the requirement that the light be turned off at 10:00 p.m. and allow the existing signs to remain, is hereby approved. d. THAT the recommendation of the Sign Board of Appeals for a variance to allow a 5' by 10' changeable letter marquee wall mounted sign above the steps on the eastern side of the Sunbelt Gymnastics building located at 4701 Bransford Road, is hereby approved. AND IT IS SO RESOLVED. APPROVED THIS AYES, DAY OF NAYS AND 2003, BY A VOTE OF ABSTENTIONS. ATTEST: CITY OF COLLEYVILLE: Cynthia Singleton, TRMC City Secretary Mayor MINUTES OF THE COLLEYVILLE CITY COUNCIL APRIL 15, 2003 The Pre-Council meeting of the Colleyville City Council was called to order by Mayor Arp on April 15, 2003, at 5:15 p.m. ROLL CALL: Councilpersons Joe Hocutt, Brad Rice and Jim Moore were present. Mayor Donna Arp, City Manager Bill Lindley, Deputy City Manager Dianne McWethy, Finance Director Terry Leake, Director of Public Works Keith Fisher, Planner Tom Niederauer, Community Development Director Barry LeBaron, Community Development Manager Clayton Husband, Parks and Recreation Manager Monica Walsh, Financial Analyst Collin Boothe, Records Manager Matt Denton, Administrative Assistant Cindy Martin, and City Secretary Cynthia Singleton were also present. Mayor Pro Tem Ginny Tigue arrived at 5:18 p.m. Councilman Rich Hendler arrived at 5:20 p.m. PC-1. Discussion of proposed amendments to sign regulations Community Development Director Barry LeBaron provided an overview of the Proposed amendments to sign regulations and composition and structure of the Sign Board of Appeals. PC- 2. Discussion of April 15, 2003 City Council regular agenda items There was general discussion regarding the regular agenda items. Mayor Arp declared the meeting adjourned at 6:08 p.m. The regular meeting of the Colleyville City Council was called to order by Mayor Arp on April 15, 2003, at 6:45 p.m. CITY COUNCIL MINUTES APRIL 15, 2003 1. EXECUTIVE SESSION - In accordance with Texas Government Code Chapter 551 , Subchapter 0 Sec. 551.071 - Consultation with Attorney on Legal Issues Raised by Public Hearing or Action Items on the Agenda Legal - Potential Litigation - Explorer Pipeline Sec. 551.071 - Mayor Arp explained that the Executive Session had been called in accordance with the Texas Government Code Chapter 551, Subchapter D, Section 551.071 - Legal, Section 551.072 - Property Acquisition, and Section 551.074 - Personnel. She further explained that there would be no decisions made or action taken during this time. The meeting was recessed at 6:47p.m. and reconvened at 7:50 p.m. The invocation was given by Pastor Royal Farris of Life Connection Church, after which Ross Foster led the Pledge of Allegiance. 2. CORRESPONDENCE, MISCELLANEOUS REPORTS OF MEETINGS ATTENDED BY THE COUNCIL AND CITY OFFICIALS, AND ANNOUNCEMENTS, PROCLAMATIONS, OR PRESENTATIONS Mr. Joe Tigue expressed gratitude to Mayor Arp for serving as Mayor and presented her with a bouquet of roses. Councilman Rice expressed appreciation to the citizens for participating in the Arbor Day and Colleyville Trash Off event. Councilman Rice expressed gratitude to Mayor Arp for serving as Mayor and encouraged citizens to vote in the General and Special Election. Mayor Arp presented a Proclamation to Chamber President Ret Stansberger in recognition of Texas Families for Freedom, a military support group, which provides donations to overseas military personnel and recognized Lee Ann Osterman, who established the organization. Mayor Arp presented a Proclamation in recognition of Child Abuse Prevention Month to Dorotha Tilley, Center Coordinator for Alliance for Children. Mayor Arp presented a Proclamation to Eagle Scout Christopher Daniel McNosky and introduced Scoutmaster Bruce Ferrell. Mayor Arp presented a Proclamation to Betty Jean Willbanks, Metropolitan United Way City of Colleyville Volunteer of the Year. 2 CITY COUNCIL MINUTES APRIL 15, 2003 CONSENT: 3. READING AND PUBLIC HEARING - Resolution R-03-2129- Consent Items: a. Approval of minutes of the regular City Council meeting of April 1 , 2003 b. Approval of minutes of the City Council Worksession of March 22, 2003 c. Approval of minutes of the City Council and SH26 Advisory Committee Worksession of March 26, 2003 d. Approval to amend the contract with Leach & Ames, Attorneys at Law, P.C. for Municipal Judge services e. Approval of an Interlocal Agreement with the State of Texas for participation in Failure to Appear Program Mayor Arp opened the public hearing and read Resolution R-03-2129 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Mayor Pro Tem Tigue moved to approve Resolution R-03-2129. Councilman Rice seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. PUBLIC HEARINGS: 4. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1397 - Approval of a Special Use Permit for an accessory building on 10.272 acres located at 816 L.D. Lockett Road, Case Z-03-007 Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1397. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Mr. Marty Stajduhar, 101 Williamsburg Court, applicant, was present to answer questions of the Council. Councilman Moore moved to approve Ordinance 0-03-1397 with the provision to remove 1 d. 3 CITY COUNCIL MINUTES APRIL 15, 2003 Mayor Pro Tem Tigue seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 5. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1398 - Approval of an amendment to Chapter 6, Article II, Section 6-34. Records of the Colleyville Code of Ordinances regarding the requirement to establish quarterly reporting of alcohol and non-alcohol sales ratios, Case G-03-005 Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1398. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Discussion ensued regarding reporting periods and permitting process. Councilman Hocutt moved to approve Ordinance 0-03-1398 with the following amendment: Add to 1 a: During the first year of any license for on-premises alcoholic beverage consumption issued to a new license-holder... In the event that no violation occurs during the first year, then the business will only be required to report on an annual basis, thereafter. Add to 1 g: In the event the City Manager finds a violation, then the business will be required to comply with Section 1.a for the succeeding twelve months. Councilman Rice seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 6. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1399 - Approval of an amendment to Chapter 1, Section 1.18.BA.b, of the Land Development Code to expand the property owner notification for alcohol related SUP requests, Case Z-03-009 Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1399. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. 4 CITY COUNCIL MINUTES APRIL 15, 2003 Councilman Hocutt moved to approve Ordinance 0-03-1399. Councilman Rice seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 7. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1400 - Approval to amend the existing electric franchise between the City and Oncor Electric Delivery Company, to provide for a different consideration Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1400. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Financial Analyst Collin Boothe provided an overview of the proposed amendment to the existing franchise between the City and Oncor Electric Delivery company. Mr. Rick Johnson of Oncor was present to answer questions of the Council. Councilman Hocutt moved to table Ordinance 0-03-1400. Councilman Rice seconded the motion. Discussion ensued regarding the proposed amendment and potential for future amendments. Councilman Moore called the question. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 8. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1401 - Approval to amend the existing gas franchise between the City and TXU Gas Company, to provide for a different consideration and to authorize the lease of facilities within the City's Rights-of-Way Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1401. 5 CITY COUNCIL MINUTES APRIL 15, 2003 There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Mayor Pro Tem Tigue moved to approve Ordinance 0-03-1401. Councilman Moore seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 9. SECOND READING AND PUBLIC HEARING - Ordinance 0-03-1402 - Amending Ordinance 0-02-1324 and approving the amended Tax Increment Financing (TIF) District Tax Project Plan, Exhibit "A", attachment 3 Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1402. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Mr. Jim Sabonis, First Southwest Financial, was present to answer questions of the Council. Finance Director Terry Leake provided an outline of the amendments to the TIF Project Plan. Discussion ensued regarding the establishment, status and value of the Tax Increment Financing District. Mayor Pro Tem Tigue moved to approve Ordinance 0-03-1402. Councilman Hocutt seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 10. FIRST READING AND PUBLIC HEARING - Ordinance 0-03-1403 - Approval of Amendments to Chapter 14 of the Land Development Code regarding drainage, fire lane, construction plans and other engineering requirements, Case G-03-006 6 CITY COUNCIL MINUTES APRIL 15, 2003 Mayor Arp opened the public hearing and read the caption of Ordinance 0-03-1403. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. 11. READING AND PUBLIC HEARING - Resolution R-03-2130 - Consideration of appointment to the Library Board Mayor Arp opened the public hearing and read Resolution R-03-2130 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Councilman Hocutt nominated Nancy Etchyson. There were no other nominations and Mayor Arp called for the vote. Council requested that staff advertise the open alternate position in June, which was created as a result of Ms. Etchyson's appointment. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 12. READING AND PUBLIC HEARING - Resolution R-03-2131- Consideration of appointments to the Celebrate Colleyville Steering Committee Mayor Arp opened the public hearing and read Resolution R-03-2131 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Councilman Hocutt nominated Marcus Miller. There were no other nominations for this position and Mayor Arp called for the vote. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. Councilman Rice nominated Dezann Korbuly. 7 CITY COUNCIL MINUTES APRIL 15, 2003 Councilman Moore nominated Linda Newton. There were no other nominations and Mayor Arp called for the vote. Dezann Korbuly: Councilpersons Hocutt, Rice, Hendler and Mayor Pro Tem Tigue Linda Newton: Councilman Moore Mayor Arp declared Ms Dezann Korbuly appointed to the Celebrate Colleyville Steering Committee. Councilman Hendler nominated Linda Newton. There were no other nominations and Mayor Arp called for the vote. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 13. READING AND PUBLIC HEARING - Resolution R-03-2132 - Approval of the City Developer Agreement with Tommy Cunningham for the Sparger-Felps Addition Mayor Arp opened the public hearing and read Resolution R-03-2132 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Councilman Hocutt moved to approve Resolution R-03-2132. Councilman Rice seconded the motion. Ayes: Councilpersons Hocutt, Rice, Moore and Mayor Pro Tem Tigue Nays: Councilman Hendler Mayor Arp declared the motion carried. 14. READING AND PUBLIC HEARING - Resolution R-03-2133 - Approval of the award of a contract with O'Donnell's Landscape Services, Inc., for the Grounds Maintenance Contract Mowing, Bid No. GMCM 1-03, in the amount of $136,891.00 Mayor Arp opened the public hearing and read Resolution R-03-2133 in its entirety. 8 CITY COUNCIL MINUTES APRIL 15, 2003 There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Councilman Hocutt commended Parks Superintendent Tim Hightshoe for restructuring the contract and and reducing the cost of the contract by over $100,000. Mayor Pro Tem Tigue moved to approve Resolution R-03-2133. Councilman Hocutt seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 15. READING AND PUBLIC HEARING - Resolution R-03-2134 - Approval of the award of a contract with O'Donnell's Landscape Services, Inc., for the Horticulture Grounds Maintenance Contract, Bid No. HGMC 2-03, in the amount of $117,587.44 Mayor Arp opened the public hearing and read Resolution R-03-2134 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Councilman Rice moved to approve Resolution R-03-2134. Councilman Moore seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. Councilman Hocutt commended staff for the maintenance and condition of the fields. 16. READING AND PUBLIC HEARING - Resolution R-03-2135 - Approval of a Construction Contract with Municipal Utilities for L.D. Lockett Drainage Project, in the amount of $230,757.00 Mayor Arp opened the public hearing and read Resolution R-03-2135 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. 9 CITY COUNCIL MINUTES APRIL 15, 2003 Councilman Moore moved to approve Resolution R-03-2135. Mayor Pro Tem Tigue seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 17. READING AND PUBLIC HEARING - Resolution R-03-2136 - Approval of an Agreement with Richmond Communications Group for the installation of voice and data cabling in the City Hall and Library, in the amount of $74,800 Mayor Arp opened the public hearing and read Resolution R-03-2136 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Financial Analyst Collin Boothe provided an overview of the voice and data cabling in the City Hall and Library. Councilman Moore moved to approve Resolution R-03-2136. Mayor Pro Tem Tigue seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 18. READING AND PUBLIC HEARING - Resolution R-03-2137 - Approval of a Tax Increment Financing Agreement for Redevelopment Site NO.2 between the City of Colleyville and Melvin & Martindale, L TO., (Town Center Development) Mayor Arp opened the public hearing and read Resolution R-03-2137 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Community Development Director Barry LeBaron provided an overview of the Town Center Development. Finance Director Terry Leake provided an overview of the Tax Increment Financing District Agreement for Redevelopment Site NO.2. and projected property income. 10 CITY COUNCIL MINUTES APRIL 15, 2003 Discussion ensued regarding maintenance and landscaping of Church Street, decorative street lights and maintenance of ponds. Mr. Charles Hodges, 13642 Omega, Dallas, Melvin & Martindale, LTD., provided an overview of the Town Center development. Mr. Jim Sabonis, First Southwest Financial, provided an overview of the financial health of the Town Center development as it relates to the Tax Increment Financing District. Discussion ensued regarding responsibility for injuries sustained on public trails and the first right of refusal. Councilman Rice moved to approve Resolution R-03-2137 with the following amendment: Add Section 2: That this Resolution shall be conditioned on passage and acceptance of Resolution R-03-2138 by Melvin & Martindale, LTD. Mayor Pro Tem Tigue seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 19. READING AND PUBLIC HEARING - Resolution R-03-2138 - Approval of an Agreement between the City of Colleyville and Melvin & Martindale, LTD., (Town Center Development) Mayor Arp opened the public hearing and read Resolution R-03-2138 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Councilman Hocutt moved to approve Resolution R-03-2138. Councilman Rice seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 20. READING AND PUBLIC HEARING - Resolution R-03-2139 - Approval of an Agreement with 3M Company for a Theft Detection and Collection Management System for the Colleyville Public Library, in an amount not to exceed $81,441.00 11 CITY COUNCIL MINUTES APRIL 15, 2003 Council considered this item in Number 19 position. Mayor Arp opened the public hearing and read Resolution R-03-2139 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Mayor Pro Tem Tigue moved to approve Resolution R-03-2139. Councilman Hocutt seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. 21. READING AND PUBLIC HEARING - Resolution R-03-2124 - Reconsideration of City Council action taken on a request for a waiver of perimeter street improvement requirements on Lot 3R, Block 2, Thompson Terraces, located at 5009 Thompson Terrace Council considered this item in Number 18 position. Mayor Arp opened the public hearing and read Resolution R-03-2124 in its entirety. There was no one present wishing to speak concerning this item and Mayor Arp closed the public hearing. Mr. Jonathan Richard, 201 Rochell Court, applicant, was present to answer questions of the Council. Discussion ensued regarding perimeter street fees and the future development of the area. Councilman Hendler moved to approve Resolution R-03-2124 with the amendment to reduce the street perimeter fee to $12,150. The motion died for lack of a second. Discussion continued regarding fees. Mayor Arp recessed the meeting at 10:15 p.m. and reconvened at 10:40 p.m. Discussion continued regarding the street perimeter fees. 12 CITY COUNCIL MINUTES APRIL 15, 2003 Councilman Hocutt moved to deny Resolution R-03-2124. Councilman Moore seconded the motion. Councilpersons Hocutt and Moore withdrew the motion and second. Councilman Hocutt moved to table Resolution R-03-2124. Mayor Pro Tem Tigue seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the motion carried. TABLED ITEMS: 22. CONSIDERATION OF ORDINANCE 0-03-1391 - Approval of a Zoning Change from AG to R20 on Lot 2, Weston Ward Addition located at 6412 Ponderosa Lane, Case Z-03-002 The applicant requested that this item be withdrawn. 23. STAFF REPORTS: MONTHLY FINANCIAL REPORT QUARTERLY INVESTMENT REPORT There was no action taken on this item. CITIZEN COMMENTS: 24. CITIZEN COMMENTS/PRESENTATIONS REGARDING ITEMS NOT ON THE AGENDA There was no one present wishing to speak. ACTION/RESOLUTION: 25. DISCUSSION AND CONSIDERATION OF A RESOLUTION RATIFYING COUNCIL AGENDA ACTION FOR THE MEETING OF APRIL 15, 2003 - Reading and Public Hearing - Resolution R-03-2140 This item was not needed. 13 CITY COUNCIL MINUTES APRIL 15, 2003 ADJOURNMENT: 26. ADJOURNMENT There being no further business before the City Council, Councilman Moore moved to adjourn. Mayor Pro Tem Tigue seconded the motion. Ayes: Councilpersons Hocutt, Rice, Hendler, Moore and Mayor Pro Tem Tigue Nays: None Mayor Arp declared the meeting adjourned at 12:15 a.m. APPROVED THIS AYES, DAY OF NAYS AND 2003, BY A VOTE OF ABSTENTIONS. Minutes taken and prepared by: Cynthia Singleton, TRMC City Secretary 14 MINUTES OF THE COLLEYVILLE CITY COUNCIL WORKSESSION MARCH 26, 2003 The Colleyville City Council Worksession was called to order by Mayor Arp on March 26, 2003, at 4:10p.m. ROLL CALL: Councilpersons Joe Hocutt, and Rich Hendler were present. Mayor Donna Arp, City Manager Bill Lindley, Finance Director Terry Leake and City Secretary Cynthia Singelton were also present. Councilperson Brad Rice arrived at 4:20 p.m. Mayor Pro Tem Ginny Tigue arrived at 4:40 p.m. Other attendees included Mr. Charles Hodges of Melvin and Martindale, Ltd. 2. Discussion and Consideration of Tax Increment Financing Agreement for Redevelopment Site NO.2 with Town Center Development City Manager Bill Lindley provided an overview of the proposed Town Center Tax Increment Financing Incentive Agreement. Discussion ensued regarding commercial development, zoning, entertainment uses and the construction of Church Street. 3. Discussion of Proposed Projects relating to Town Center There was general discussion of proposed projects relating to Town Center 4. Adjournment CITY COUNCIL MINUTES MARCH 26, 2003 There being no further business before the City Council, Mayor Arp adjourned the meeting at 7:05 p.m. APPROVED THIS AYES, DAY OF NAYS AND 2003, BY A VOTE OF ABSTENTIONS. Minutes taken and prepared by: Cynthia Singleton, TRMC City Secretary 2 CITY COUNCIL ca@niB AGENDA BRIEFING Il'X"::; MEETING DATE: 05/06/03 CITY MANAGER ITEM# : RESOLUTION # : 7c R-03-2142 DEPARTMENT HEAD ":reM FINANCE REVIEW, N.A. Previous Action: None DEPARTMENT: COMMUNITY DEVELOPMENT SUBJECT: Approval of the recommendation of the Sign Board of Appeals for a variance to allow a 6' tall by 11' wide by 22" deep sign at the entrance of Good Shepherd Catholic Community on Tinker Road and allow the existing signs to remain, Case G-03-007 - by Consent Reading and Public Hearing Good Shepherd Catholic Community is currently constructing a new 36,000 square foot facility on its 16 acre campus at 1000 Tinker Road. In conjunction with the new building construction, Good Shepherd Catholic Community is requesting a variance from the sign regulations to construct a 66 square foot institutional monument sign and to allow the existing 32 square foot monument sign to remain. On November 12, 2002, the plant manager for Good Shepherd Catholic Community contacted the Colleyville code enforcement officer and was advised that an institutional sign was limited to 90 square feet. The plant manager was also informed by the planning and zoning assistant on the same day that two monument signs were permitted on the property so long as there was a minimum of 60 feet of separation. The plant manager subsequently placed an order for a block of limestone for the sign's construction under the assumption that the 66 square feet was well under the maximum size limit. No permit had been applied for at the time this information was obtained from City staff. However, on April 15, 2003, a sign permit application was submitted and denied due to the sign exceeding the size limit and the existence of a monument sign on the Tinker Road street frontage. The applicant was advised to request a variance from the sign regulations. Current Requlations The maximum size institutional monument sign allowed by the current sign regulations is 32 square feet. The applicant is requesting approval to construct a 66 square foot monument sign. The maximum height of a monument sign under the current regulations is 10 feet. The proposed monument sign is only 6 feet in height. The current regulations only allow one institutional monument sign per street frontage. The proposed monument sign, if approved, would be a second monument sign along the Tinker Road frontage. Agenda Briefing Resolution R-03-2142 Page 2 of 6 Proposed Requlations Over the past year, the City Council has been reviewing a proposal to revise the Colleyville sign regulations. Included in the proposal is a revision to the size regulations for institutional monument signs. The following is an excerpt from the proposed revision to the sign regulations. B. Institutional Siqns - These regulations provide for on-premises and off-premises Institutional Signs to assist the public with the location of these types of uses. 1. On-Premises Institutional Sign: The purpose of an On-Premises Institutional Sign is to identify schools, churches, hospitals or similar public or quasi-public institutions. One On-Premises Institutional Sign per street frontage shall be allowed on the premises where the institution is located and in accordance with Table 7-1. All On-Premises Institutional Signs shall be constructed as a monument sign as defined in this Land Development Code. The maximum area, height, spacing, and setbacks of an On-Premises Institutional Sign shall be in compliance with the specifications contained in Table 7-2, provided that an On-Premises Institutional Sign located within a commercial zoning district may comply with the requirements of a General Business Sign. Max. Area 45 s. f. T Lo Institutional Sign (On-premises) a. Minimum Setback: Eight feet (8') from an abutting street right-of-way and thirty feet (30') from any side or rear property line adjacent to another property. b. Minimum Thickness: No On-Premises Institutional Sign shall be less than four and one-half inches (4- Y;,") between vertical face planes. c. Changeable Reader Board: An On-premises Institutional Sign may include a changeable reader board area, provided the combined gross surface area does not exceed the maximum sign area and provided that no more than fifty (50) percent of the maximum allowable sign area may be used as a changeable reader board area. A permit is not required to change the message on a changeable reader board. For purpose of this regulation, a changeable reader board may include an electronic message area. Analysis The Good Shepherd Catholic Community campus has approximately 410 feet of frontage and three driveways on Tinker Road. There is one driveway on Pleasant Run Road. There is an existing monument sign adjacent to the Pleasant Run Road driveway. There is also an existing monument sign located adjacent to the western most driveway on Tinker Road and situated approximately 60 feet from the southwest corner of the property. The proposed new monument sign will be located approximately 210 feet east from the existing monument sign on Tinker Road and will be generally centered on the new church building. As a part of the process for preparing the proposed revisions to the sign regulations, staff conducted a survey of existing institutional monument signs and compiled a table showing the sizes, heights and other characteristics of these signs. The information obtained from the field survey is shown in the table below, which has been arranged in order of descending size. The largest institutional monument sign in the table contains 98 square feet. It is not clear when Agenda Briefing Resolution R-03-2142 Page 3 of 6 this sign was constructed. Many cities have sign regulations that contain a formula to allow larger signs in proportion to the lot size or the amount of lot frontage. Colleyville's regulation for institutional signs does not contain this type of provision. City of Colleyville -- Institutional Monument Signs Address Business Name 2600 Hall-Johnson Rd. Highland Meadows Christian Ch. 715 Cheek-Sparger Rd Colleyville Presbyterian Church 5800 ColleY\filleBlvd. Colleyville Elementary_~~ool 601 Glade Rd. Bransford Elementary School ~ 3.~8 Glade_~d. Colleyville ChristianFello'^'ship____1 ~901 Pleasant Run Rd. Pleasant Run Baptist ChLJrEb ...1. 3708 Glade Rd. Pleasant Glade Baptist Church ! 5601 Pleasant Run Rd. First United Methodist Church 5300 Pool Road OC. Taylor Elementary School 1110 John McCain Rd. St. Mary's Orthodox Church 5304 Colleyville Blvd. First Baptist Church 2512 Glade Rd. . Pleasant/Glade Assembly of God 1901 Industrial~lvd. F<illgdom Harvest Church_'_ 5312 BransfordRd. I Church of the Latter Day Saints 6300 Pleasant Run Rd. . Good Shepherd Catholic 6605 Pleasant Run Rd. Crown of Life Lutheran Church 1000 Tinker Rd. Good Shepherd Catholic 3801 Glade Rd. St. Mary's Romainian Church 3209 Glade Rd. ! Sonset Baptist Fellowship Church Summary and Conclusion Height 7.0 6.0 8.0 8.5 8.0 7.2 7.0 5.0 5.5 7.0 5.0 5.0 4.9 6.5 4.0 4.0 4.0 4.0 4.0 Size of Sign Width S. F. 14.0 98.0 12.0 72.0 ~l~~~ 8.0 56.0 11.0 55.0 10.0 55.0 7.0 49.0 8.0! 40.0 8.0 j 40.0 8.()j _. 39.0 5.0 35.0 8.0 32.0 8.0 32.0 8.0: 32.0 4.01 16.0 3.0! 12.0 While staff may have erred in providing incorrect verbal information, a permit was never applied for by the applicant for staff to formally review. Staff review of a permit application would have discovered the oversized sign being proposed and that there was an existing sign along that street frontage. However, even had the applicant applied for a sign permit and the permit denied, the applicant could still have applied for a sign variance. Staff notified all the adjacent properties regarding this sign variance. No written comments have been received regarding this variance request. According to Section F (5) of the Sign Code, the recommendation of the Sign Board of Appeals regarding all sign variances is forwarded to the City Council for consideration. At the April 21, 2003 meeting, the Sign Board of Appeals recommended approval of the sign variance request with the following requirements: The lights on the sign will be turned off at 10:00 p.m., and that other, existing signs would not have to be moved. Agenda Briefing Resolution R-03-2142 Page 4 of 6 Recommendation Approval Attachments · Site plan of church property · Photographs of existing signs · Letter from plant manager · Sign permit application . Drawings of proposed monument sign · List of property owners notified Agenda Briefing Resolution R-03-2142 Page 5 of 6 Site Plan of Church Property Agenda Briefing Resolution R-03-2142 Page 6 of 6 View of new church building as seen from Tinker Road Monument sign located on Pleasant Run Road Monument sign located on Tinker Road approximately 60 from the southeast corner of the property . '- -...... -"I 1 'r ~Moore,\' I' \ Siga B8f1I~ of ~p~! , (, ~ ~P.Q.B6x 185_ ) ~~' ,I , .J I- ,'/' , / ' ~/o Community,DevelopmeIlt ' I 0 / r! - ~ t' ~ /' Tom~~di~t ,'/ ( 1_ '''-., '/ , ; ~,\ ~ ' "~ 1/ .colleyville, TX 76034' , ,~,\' .J " - " f' farish Centf] '''- ~ · r / i.lqOOTlnkerROad "" (\ " . i ,(j' I' ,\.;J Colleyv~l~, Te~:is 76034 ( .~., ,\ I ; , , -/8~Jf~1-1387 \..c,. -, '. I I, ;~ ,- -,' .I,. / ,,/'f,. '\ " {' !l17J.421-139;t' , pem:.c~ Moore, _ /., ,';~f " " (>c. /' '- ,J ,I /' 'f'Ax817!'42~-4109 ),' '--'~ ",",- / / -'.\ ," .,,' " ,":'. I (' \, ,- Wheti w~firSt re~an t~ Rre~deSign work f~t ,tl,1e Pqrtetdcher~ at our n~ '- ' Past!or~LAdmi~:~tTato,...' ':WOl;Ship sp~;,.We anticipated the n&d fqr a sign. . BaCk OllNove~r ,12;)2092, ,I J' k ThereSa.1<hiralla.h, S,S~D {ca11td the'<;ityoJCon~e!'Pd,requeStedirifo~ti5>n-i~gfU"Q,ing the ~ocation, ~izc!l~ Sr. Dorothy Bggeriji, S:S.N,D, ",.~; gptPhic~ does it need8IHld~es~ e!,c" ,DD No~ h?t~~, t ~~ the' '; clto/~d SPO~W1th,St~ve P.e~e7; ";110 ,m~ICate~ }?,,~,that ~~~ltutip~)Sl~ ~ould , not exceed 90 squar~ feet per slde. My--descqptiOn of --the ~ ~ that It would.J,e , v. eithei, aboU)der, with ~ven faceS, or a pi~ df quarry funestone ill a stab form..:..." , ~~her 9<>~me~ui~ appfo?ciIrnftt?ly T. bY(ll:(~~s 22'\ _'!~21;). We- wquid theu/ / ;;. CaJiVe OJ sandblaSt the thurcl):'s.name:nMo the. face o/the st.orleJ- GOOD ~'pHERD , \CAta9L}C COMMUNI,~: . St~* said t~ the sign.~ be up ~ 10' qigh..(~" .'" , -( - ~ -.' - - 1\ (, I ' \ - r;th~spoki,Mth Ian Le~,the ~ day, fro~ th~ dty arid ask'ep her'about,the-;ign-- / ( '. requ4'ernents:~. BeCa~ we already~hav~ a: sto~e s~o~ TiDk~ Ro~l'wante~./'- . to. know if this woillQ ~ ~f$robleI1L f w~'-toldthatif.tp.e two\signs!were fit le~t 60' \ apart, ther! wo~\be no froblem to hive ~o~~igns on\~e ~'- ~e~! ftontag~ ;\nG because we are ~ ch~c.h, tl1at s~~ools and-ch'rr.che~,:caIlJx: ~v~ if neces~. J w~ , tol4 ofthef~~ pro~ess retp.l1nng'~e1eyatIon oftIw s~ ~~ smaIl plot of the . (~ ~ lan~ t~t [ fo~ woutd~eed~o h;filled out~~ele'f~cal pennit would be I.~ '; neecled f9f the two lights for;,illlJI11IDatlon: Whenc.QJrr genera1 contraqtor went)o.:the X" " .citf to ask fOr a pe~t Iast~ek, he was told iliB;1; tilt) sign c~'tt~ceed 32,s~feei~ ~, . (\ - , ~ -' - _-../" ,-,...- - (/ \ I{, . ",-' ' ,"-, I \ ""\ I.. --\. >: I l -! ' " ).- -):y We had movhfforward with{)ur design; 16cating and.piircbasingofthe limestone sigD, eng~ermg the, foundat;ion for tHe sign (and haVe exceeded ~ hours b{ t~' and, . , dolladiq p9fSllit ohhis en~U~~vor. FOlloWing-the prone iDfQIll)ation\~badrec~ived from tli~ city"'m November zp02,we moyed ~~d - (,nly to' find out t~ . what ~we "',, ".J' ; '- . \ . ". '. . or ~ .w~eJol9:<woul<tbe o~ay to install IS n9~ something :against th~ code.'. ( ~ . I' ~ ~ \, . , '- -/ I... '.--'( , .J r- '\ ~ ~r- 'I( ) .-: ~~ }<' ) /--' ) j i/' \i ') " ./ "\ '\ \ T , " ..., -~\ '--. \: )- , "- l, ' ....' f- I, "- / - ,,1\ ~ Good Shepherd -Catholic Community _. \ .' - I J --- ):~', . '. , ' ,L J , , ( - ('"I ' c' '- -.., r ,..... , .J. ) "--, \,. r " C J '. \ i ~I I ( j/ y' ~ I , J . I " ~ / .~ r - I \ \ - , Appn 5, ,2003 i " , l i , \ 1\ " ~ ../ .J \ '- J r I r ' " '- f " .-/ . I - / ( I ..J ,__ ! / \ 0...- j ..J / I / ) ~ ,-' " ',-- < .- -~_. '../, I " c , J ( J , " "'- ~ " , J " _ f _,r; /- j ". ,./ (' I ~I ! ~ -1"' /" 0, ,f(" -" ,~ i -' / ,/ c \ (" I>., ,~ 'I -I ). I \ I / I . ~ "'>. I "",' , ~- ", '" , ,- ',r ,--' I" \' - ,', ., l" (,' / " " -f _ ' We' ask that our ~ Thnestone si~PaSicaI1y 6' taU by-\ 1 ~ wide b~ 22''' 'dee~ be ~~epte~_ by the city in ~O()~~fait~' We 'were foJo~ the, diiect~on of~cl~ ~n /' ~I, ,; _ we mOved forward. 9~ ~~h, and I per~,JUlve wo~ed ~/~ ~1ty for some, i 0 years ~ow as a go6~ Iie~hb()~. We request that~e be,.ghuit~ tlili; vanan~e for oUr , ~stone sign. 'We also l:lsk,!hat we,IlQ,tbe obligiited ~o mOve tEe exiSting stone ,si~ onour~er~Ro~'t?ntrY.- ) ;- , \ i j , -f: ~ :: \ ( \.. I ..... ,~ - In gratitu4e~ - ' /; 'IM-, "riJ'-~j P,-~ -\ ,~,'-", _,' I,' \', ) r !)en Bur~ ' ) plat;tt Manager' , / , ,~' -:tJ9Qd Shepherd-CilthoJic ,cOrritnunity ^ " // J .' . ( I' ~ /- , r \. 7' / "'I..... ./ , I I/' .J:: ;, \ 1 - I' /, " r \ '( / ' , /' " 'KB:eI ,,,/ " II \ - '( :: , I '- L '- 1 I :~~ ,J <- ;, ;- , c i' I - \ \ -- ' "- .J " , I 'i' \ ,/ ... ". '. r L, " f - ( " J ~ " , \ \\ " I F { \' :> \. '- , '- I' I /' I( '" /i' v~ /~ / '\ "'" / ^' - ('; 'I -'" \, '\ -l '- \ j ;J \ " , " \ \ , _1:':: / -., '\ "\ J I --." _ /--- Ap~-Utl-U~ U4:~~~ dorothy 1 posey 817-577-7564 P.02 SIGN VARIANCE APPLICATION Oate of submittal: This application must be filled out in its entirety for consideration and review 1- 1S"-tJ3 ........................ ")i......... ....... .......... ......... ............ .11........ ......... ........................ .... A. Applicant: (D()OO ~o -r~L.(f!.. lIJ~.JI.hfl . ,.;f ) Address: (bOO ~lt:.evc.. R.p ((EAl ~~{- ~-IpJT I,(,J~R. ~l.1..1::'1 u,uE ~ 740,4 8f7- 4'2. ( - 1387 Phone: ... .... .... ... .............1.. ............ ........... ..... ... ......... ............111.. '1'1 .... ....... 1..1... .......... II ....." ... ..... B. Owner of property: Name SIfM~ Is ~d€' (~AJ(/) 4hrlf; 6,sijopJoSE'Pl{- P€lJtUe, Utilt>'f~ D(DtS€" 4'F .g tJ~.:rff J ~ Address: Phone: 8r7- ~~ - .3 300 ........ ..... ......."".1.... 1."".1 .., ............ II .........." II.. ........ 1..1.. ..........".1 ... ... ... ... ... '" ... .... ... .... C. Location of the Sign: fOOO number -r; A.I K.~ f!.tJ. street name Address: .. "' ........ .......1........" II ...... ..... ... .........~.. ...~.. ~... ......... ...... ~ ........ ~...~... ....... ~ ........... ..... ....... ... D. Other information that must be submitted with this application: ./ Scaled site plan showing: /1. /2. t/ 3. V' 4. Location of any buildings, structures or tract to which or upon which the sign is to be attached. The position of the sign in relation to nearby buildings, structures, or other related signs. dimension of setbacks, building lines, distance between the proposed sign and street, distance of proposed signs and property lines drawing of proposed sign including height, width, and area. ./ ./' Detail plan of the actual sign. A detailed letter indicating why your sign can not meet the requirements of the sign ordinance as well as a description of what your intentions are in placing GoP~ Citr-r(oLfC- C"",,^J,J,'n7 1-8-03 ( Lu E'D cC-~ 1; M. EO 1O,J1!' - A.." ~8J-r/rt- Si~ N) . f 1S01J je.fF. 3 &OPOSE'D .. .. t 10, 7 f,;,JS (/\J 2/) 370.e4- ) [ 4 n~o I / V (.fiftE of ;5 liP tJ ) 7 71 " -() r : fp,O !ftol15Jf ~ /'--0 ,~D ~11v- . ~ 6{\t s 6cO ~ D 1-1 L-- J,J ,11 ____ ---- c.J\ r Ie D*^'^ ~ /'---- ~ B.~fo;o )r (r- ~c~ ~u~p.. ,I I Y]/O j:f ~ /' /'" j~ (j5jLl- 817- 42-1- /38 7 /' I i r '.L ==~~~"--~~t \j _~_ .------.--- ~JU-b --------- ~- :~~- -- ?G-~. - .T~2_=:J ---~-itt1t=~ ___ . , f;Q/1tvltNI3[Yj ".-- ----.----.---4--~-..____._____..- __ .____._ ..__ _.~. ~---'---------;...-,----...._---_._____ _v___. ..." '_._ .-.-.-.-! _. ..... .-..----.---...... _..-. .----------.-----..j ",-,'--" ..,-~'-~~_.----'_._-._._._~._---_._-- ...... --- ) ... Hr-r<:-LIO-lQ':' ~: ,!~~JJ fttLtW ~t~11 ~ lll'1 ~RMHto~" ~\: I'-.l: tltll~\ f)HlbN h~t\tI"F4f. ~lhl (. ( (<'IN . -v- \: II "~ ;0 o ~ . - IHU 1O~:~6 JIM BRANSFORD ARCHITECT --- - -. --". '''- ---..,.., p.e1 p.a2 817 834 1667 ~1. (" . (o68~ ' 11~\ .._~~~.i~__~, ~_.,..~--. 16 . . " ~ ... . . , 1 ,-.. J"', . .. I ...... . " ~ . J. \ , . ~ o ".. .', I ~\J I'? 3 '- 7'k'. fll-1.. c^,v1rt WI II t(~ H .s r1\tN(,T It .4^DIIT Aft€-" . fL"<=fMt.N r ot: <'t"ONE- Jll-=ltI'.~ 2 &1 ~ 'I" L-J ~ L;. Q.C. ~ '-$ " ,I ~ FOOTIN ~ , !D~ MDN II ~tN~~~" SIGtjJ DE-TAl L . b . &A l.. f,.: ~ II ~ 1'. (J If " ..~~ ~" ~rUl 0'" . N ~ .c. . CD~ N C> " ~ c..l - ~~ .., I .. 8Eti ~. CO t. \ t- t ,., ~ - N QI E;;;; <(€ to Q t::Q~ 0 0 Z G> OUIl 'E~ ~ a~~~~ a. .g =a ,91: ti (5U mO CD ~~V7~~ ~ c:u. "[ CL(j 4J I,S) '0 !! a. ~ ~ '0rD (j en "0 E "- CD :::; .c i .J::. :{ ~. 'f/) (" "0 0 0 .:z I ,C) I I r \ ~ ' ----\ " 1 ,I n___'- ---7 , I \ \ . i; i ! 5' -- II . e ..... : : ;. tj tL i I < .C: Q ~ > 41 ill ;; :3 o en ::1- . i ! I..... I j ~. i . ~. ,;7\ .: I c o 'B ~ . i ! . l '\ i I c: o ij Gl en .., a r C\.G -.& ~ a -J C'Q ~ \ ""t: ~l_ ~! ... - .. - $- I b C') Jf~ \ .... l-v :J \- c ...... ~ III <\: ~ .0:: 0 '"" ~ ~! 0ij] ;-: ~ &-'1/ .'" ----- ~ ;t. ~ .(:' J -J ~~,' ~~ .:s i c..---~ ~~ i ~ ~( o 0 ~ ~ N III * >- . rd 0 ~ <: Q) .~ < .2 co e tlg [L. 3 G> ?:- aa: .~ "So E ~ l! E .~~ ~ ~ :E(i '0 ~ .~~ s= "0 - "0) Ci c: "C 'C: U tV ; 0 _ eo -e.~ 4)5 ~~o liic: -Q.Q.u; '-~Q)a.cu ~i ...~=.~ ~ "C cu 'i _ ~-5-e-g.i . '2C:O'~Nts~. .- Q) '" C') III 0 ft!~g~~~ f<llca....*8.!!! I;:OS=o.., 5 .r::~u-eu"O.... -o"'O'~eIl0 .~-c8.lPe1ijn "C.~ 0 ~~ 2 III 8. Q)tVou:: Q."O 'O's= "'" _ c: ':iliiliU~~8 0"0 lUc::2_ GlNlPlU'i::J~ .855~e2'5 -oE=OQ)'C: :S:"OO~ C:O ~-~I'JJ'Ooc CDIllCU"'C:U;._ i:1C:lP<Iloc: iJj .r:: .c: 0 '8 iii E .gt W UCl 0::1:=.. 0= i!i:u c: lP 5 b u(,ol)~5'c: CD. c: 1:: cu z 1:o<llOtScu):( I- o:;a,uo..CU-gCD U 0.. t:' :!:: cu .~u .... W'CDIUE,c:.ec:o ., .r::~Ol-o..__ o 1-1-.. .n g: "':N"'. "C :0 .S <II E ~ 4'5~~ l ~>:',' ~:. I~. I .... ,T}..{ ..) \ ..... ..." ~ "'~:~':.t'~'" ~ ~ " . '. "'~--J t1. '<.... "T-;> t Q 6;;t~~1)'t ~'" \... '.i.! Q~' J;,.<:'-' I~-,~,,,? ,:-\.;: I ...,. "., . <. ....,. . I dtt"b C' ~ "'rr~ _or ...., "'\"'. . ' . \:~ '''j~l'/>8:. I>~~' ;;:.~ _ r.;~ ~<~ . // ... b." lit .\::J ~ '~:"~.'~V'. S ','"" j,.":--'S./l ( .\ ~, , "..-,,'. ',cO,. ",'9' ",... ~" ~ '\, "'#.,:J:;',; -i':.:j,':> -.. \C~ "oli:c;",,,. ~~,~ ~1 . ~~~ ~~v~ . ~~\~ . ~W!~ t'-- ~ ~~~ \ . ~~ \ . "'1 il) \' \ i J 1Il~:t ~ '2 ~ '= ::JI- 8E..- ~ ~.~ aU= [L.gS o -5 ,IV U ~ ell .r; a. Q) .r; C/) '1J o o C> '~ "-l ~ u:: Q) )(. ... .. .- I- ~~ <5 ~3= .2:5 11)1.1.. c: 10 .... m E :.::; ~. ~ ; ~ ~ ~ ~ rb o G> Z ni U C III '0" 0.: List of Property Owners Notified Burrow, Marian Alice 6405 Pleasant Run Road Colleyville TX 76034 Burrow, Darrel D Etux Marian A 6405 Pleasant Run Road Colleyville TX 76034 Dolan, Thomas D Etux Edna 6317 Pleasant Run Road Colleyville TX 76034 Delaney, Joseph P 800 W Loop 820 S Fort Worth TX 76108 Vencill, Robert Etux Shirley 6215 Pleasant Run Road Colleyville TX 76034 Westbrook, Sandi & Chas Gorena 909 Tinker Road Colleyville TX 76034 Denman, Darin Ja 911 Tinker Road Colleyville TX 76034 Kepp, Nancy J 1005 Tinker Road Colleyville TX 76034 Davis, Gary D Etux Mary Ann 6400 Pleasant Run Road Colleyville TX 76034 Davis, Ullin D & Patricia The Davis Family Trust 6316 Pleasant Run Road Colleyville TX 76034 CITY COUNCIL ca~", AGENDA BRIEFING iC'x~$ MEETING DATE: ITEM # : RESOLUTION # : 05/06/03 7d R-03-2142 CITY MANAGER j DEPARTMENT HEAD j FINANCE REVIEW j Previous Action: None DEPARTMENT: COMMUNITY DEVELOPMENT SUBJECT: Approval of the recommendation of the Sign Board of Appeals for a variance to allow a 5' by 10' changeable letter wall mounted "reader board" sign on the side of the Sunbelt Gymnastics building located at 4701 Bransford Road, Case G-03-008 - by Consent Reading and Public Hearing Sunbelt Gymnastics is located at 4701 Bransford Road at the intersection with Centerpark Drive (see Attachment 1). CGS Signs is requesting a variance from Chapter 7 - Sign Regulations, of the Colleyville Land Development Code to construct a 50 square foot wall mounted "Reader Board" sign (see Attachment 2) with changeable letters to be used by the owner to announce events at their facility. Currently there are no provisions in the sign regulations to incorporate a changeable "reader-board" in to an attached wall sign. The current regulations allow changeable message boards as a portion of a freestanding Multi- Purpose Monument sign. Current Requlations Wall mounted signs are permitted for General Business purposes limited in size to "two times the length of a building fa9ade. This building is 197 feet in width, therefore single or multiple signs as large as 394 square feet are permitted on this wall. The existing "Sunbelt Gymnastics Academy" sign is only 90 square feet and the proposed "reader board" sign is 50 square feet. The combined area of 140 square feet is well within the 394 s.f. allowed by the current regulations. The proposed sign regulations currently being considered by the City Council limits changeable reader boards to fifty percent of the area of a monument sign. There is no provision proposed for changeable reader boards attached to the side of a building. Analvsis The applicant initially requested approval to place the changeable message board toward the northern end of the building (see Attachment 3). However, at the Sign Board of Appeals meeting on April 29, 2003, the initial location of the sign was denied. The Sign Board of Appeals has recommended approval of the sign variance request, provided the sign be situated under the existing wall sign on the east side of the building as shown on Attachment 3. Agenda Briefing Resolution R-03-2142 Page 2 of 2 According to Section F (5) of the Sign Code, the recommendation of the Sign Board of Appeals will be forwarded to the City Council for their consideration. Staff notified all the adjacent properties regarding this sign variance. No comments have been received regarding this variance request. Recommendation Approval as recommended by the Sign Board of Appeals Attachments · Location Map · Drawing of proposed sign · Photograph of building facade · List of property owners notified of variance request _..____u_. ~CF-~ [\!'1D . 5tU \1\ ~s 1 I 2."79 . IEl I AC Hl 2:< 2.9 AC {. fR 21'\ Tn ?Y 1 AC 2 At .J :Lr] .11'.1 '!IO~'U (;1' 23 22 21 ,. ,7 ~ Cf\~G1Z AOON ~V _. J I ~ TRACT A '"' '" TA 20 10.0 AC ~ _ 'ZO~ o p"C. 8.B.e'SuPI/E{ (1.z0G 1R tG 1.'" AC TFl 19 .~19 Ae " '" ~~ Ii.! 1R 182 1."7 N:. TR lC1A 1. 928 AC TA ICI 0.: "' . . 19 : . 4A fR Ie J.l AC 1 .754 AC , ~. ~. g 5& o ,., '" .-1 ,.., f [\DD g 1<ROGGR u 1l!J.B25 . ._u_u_u_~ Tn 28 1.1lI AC TR 2U fR 7....\ IACt.2AC TR 2H I AC Tn 21] 1_3 At TR :2C 1.111 At TR 7'" 1.2 "c d~,l ou~b '~029 . TR 2lL TR 2E 2.14AC I.C!lAC , 6.50 D BLACK DR ~~1~- I [\0 flR~t'lD TR 2V 2.9 At IA 7.59? II .3'l' - · E ~ TR 2/\ 1.\ AC : -"I.. I ~_: '" ., ::; ~~ TA ;?K. 4.3 AC It r p. Fl( .------------ r:t'l'fG 'N '" 1 c:: C [\01> ~/ 8.9'.' . 'Z ,,) ':g:~~o'\)\JD~ ,--- . I ~ _ ,'Iii . ~------'(o-!? I, ""I \ t' ~I ,.'I. '.' l' - -- w~__ ' . ' / /', ----------.: TR 2L ".0 a T" 10 Attachment 1 - Location Map ..a 0 ~ ..., a- CD ~ .... .... u CD en .... .. -- CD - CD .. .. ~ CD CD ...I a - :) CD - IT CD C 0 :) a- U'" E a .. N ~ a ~ >- CD .- I ~ - .- C) ..a E a CD C) - CD . m . 00 ~ c ..a a .c C U ::) '" . - 0 -0 Attachment 2 - Drawing of Proposed Sign Attachment 3 - Photograph of Building Facade Krivsky-Bartusiak Inc. 3220 Clear Fork Drive Hurst, TX 76054 Grand Prairie No Five Inc. Dba Eagle Transmission 2317 Clearview Ct. Lewisville, TX 75057 Richard & Terri Ervin 1155 W. Wall St., Ste 101 Grapevine, TX 76051 Dasta Inc. 3121 Glenmere Court Carrollton, TX 75007 H & R Buckner Enterprises Inc. 4616 Colleyville Blvd. Colleyville, TX 76034 Cindy Boykin GGS Signs 7348 Tower Street Richland Hills, TX 76118 Case G-03-008 (Notices dated: April 22, 2003) According to the last published Tax Record, the above individuals own property in near proximity of the sign variance request. I certify that the parties listed above have been notified of the proposed sign variance request. Jan Levy r;I- Planning ;~Oning Assistant CITY COUNCIL cae<ll AGENDA BRIEFING 'ex",$ MEETING DATE: ITEM # : ORDINANCE # : 05/06/03 8 0-03-1403 CITY MANAGER ! DEPARTMENT HEAD ! FINANCE REVIEW I Previous Action: 04/15/03 DEPARTMENT: COMMUNITY DEVELOPMENT SUBJECT : Approval of Amendments to Chapter 14 of the Land Development Code regarding drainage, fire lane, construction plans and other engineering requirements, Case G-03-006 Second Reading and Public Hearing Standards for concrete streets have been modified from 3,000 p.s.i. specifications to 3,500 p.s.i. concrete in the attached proposed amendments to Chapter 14 of the Land Development Code. First Reading and Public Hearing Chapter 14 of the Land Development Code contains engineering design standards for public improvements, such as water and sewer lines, street projects and drainage facilities. Over the past several months, Community Development and Engineering Department staff has reviewed the regulations in this chapter in response to repeated questions from developers and their engineers for clarification and/or interpretation. Additionally, state and federal requirements that have recently been imposed on municipalities need to be incorporated into the applicable sections within these regulations. Staff solicited and received comments and suggestions from area engineers and developers who responded to our mail-out on December 13, 2002 advising them of the proposed revisions and requesting their input. Many of the comments and suggestions they offered have been incorporated into the proposed text changes. At the March 4, 2003 Pre-Council meeting, the discussion regarding the sewer service line repair policy resulted in a directive to staff to include the appropriate regulations in the Land Development Code to clarify the inspection procedures associated with new sewer line installations. Language has been added in Section 14-165.G to require a video inspection upon sewer tap installation. Also, at the March 4, 2003 Pre-Council meeting, staff was requested to compare the cost and technical differences between concrete with a 3,000 p.s.i. strength and that with a 3,500 p.s.i. strength. Staff contacted a local concrete supplier who indicated that the cost difference amounted to about $1.50 per cubic yard more to go from the 3,000 p.s.i. to 3,500 p.s.i. concrete. This represents a cost differential of approximately 3% more to increase the concrete strength specifications for a typical subdivision street. There is no additional labor or Agenda Briefing Ordinance 0-03-1403 Page 2 of 4 material costs. Charles Jackson of CMJ Engineering recommends our going to 3,500 p.s.i. concrete for roadway construction projects due to the extended life expectancy of an average street. According to the information obtained by the Colleyville Engineering staff, there would be no issue with brittleness of the concrete due to the increased concrete strength. Staff also contacted our neighboring communities to determine their concrete specifications and these are shown in the following table. The specifications contained in the attached draft version of Chapter 14 have not been changed, pending direction from the City Council. RESIDENTIAL STREETS (Concrete) Thickness Strength Rebar lin\ Insi) (size & sDacinD) Colleyville 6 3,000 #3 @ 18" centers NRH 5 3,000 #3 @ 18" centers Hurst 5 3,000 #4 @ 1 8" centers Euless 6 4.200 #4 @ 18" centers Grapevine 8 3,600 #3 @ 24" centers Bedford 6 3,000 #3 @ 1 8" centers South lake 6 3,000 #4 @ 24" centers Keller 6 3,600 #3 @ 1 8" centers A brief summary (Attachment 1) outlining the most significant changes being proposed for Chapter 14 is included with this memo. One of the most visible changes being proposed is the manner in which the chapter is organized and presented in order to make it is easier to find certain topics through better paragraph notation and re-numbering of the various sections. The original system generated numerous complaints regarding the difficulty in navigating through this chapter. Attachment 2 is a copy of Chapter 14-Engineering Design Standards of the Colleyville Land Development Code that has been marked to reflect the proposed changes. Text indicated as "strikethrough" is proposed for deletion and text shown as "bold/italics/underlined" is proposed to reflect new regulation. Recommendation Approval Attachments: . Attachment 1 - Summary of proposed changes to Chapter 14 . Attachment 2 - Copy of Chapter 14 showing proposed revisions · Ordinance 0-03-1403 Agenda Briefing Ordinance 0-03-1403 Page 3 of 4 Attachment 1 Summary of Major Changes to Chapter 14 of the Land Development Code 1. The "section and paragraph notation" is being revised to assist in better organization of the regulations and for ease in making amendments in the future. 2. The term "Director of Public Services" is being changed to "Director of Public Works" to be consistent with the term used in the Colleyville City Charter. 3. Section 14-120 - The changes are proposed to clarify the regulations regarding construction specifications and City-Developer Agreements. 4. Section 14-125 - added language to Paragraph N to reference street sign standards. 5. Section 14-125 - added Paragraph B to address the minimum number of copies of plans a developer is to submit. 6. Section 14-125 - The changes are proposed to clarify the regulations regarding construction plan requirements. New paragraphs are added regarding storm water pollution prevention requirements and to require a street sign plan. 7. Section 14-135 - A change from 3,000 p.s.i. to 3,500 p.s.i is proposed on commercial and industrial driveways. A minimum distance for a driveway from a storm water inlet is included, and the driveway construction standard is changed to match the construction drawing detail. Substantial requirements for fire lanes have also been added. 8. Section 14-137, Paragraph I - the outside turning radius on a fire lane was changed from 54 to 50 feet. 9. Section 14-145 - added Paragraph A to require the installation of street signs by City work crews, but only after the developer has paid for the installation costs. Also, no building permits to be issued until all street name signs have been installed in a new development. 10. Section 14-145 - added Paragraph F to allow the installation of custom street signs with the approval of the Director of Public Works, provided there is a written agreement for maintenance and replacement. 11. Section 14-145 - A change to the street sign regulations will reference the Texas Manual on Uniform Traffic Control Devices. 12. Section 14-150 - Language is added to clarify the applicability of sidewalk and pathway standards. 13. Section 14-160. Language is added (Section E) to provide spacing requirements for fire hydrants. Agenda Briefing Ordinance 0-03-1403 Page 4 of 4 14. Section 14-165 - added Paragraph G.8 to stipulate that all sewer service lines must connect to a public main line and not to a manhole. 15. Section 14-170 - Changes are made to paragraph G regarding culvert design. 16. Section 14-170 - Changes are made to paragraph H regarding bridge pier design. 17. Section 14-170 - Changes are made to paragraph I regarding channel designs. 18. Section 14-170 - Changes are made to paragraph C regarding single-family coefficient of runoff and paragraph J regarding detention design. 19. Section 14-180 - Changes are made to paragraph A regarding preliminary drainage analysis guidelines. Attachment 2 Chapter 14 - Engineering Design Standards Showing proposed changes Colleyville, Texas, Land Development Code Proposed Revision 4/15103 Section 14-100 Purpose of This Chapter The purpose of this Chapter is to establish minimum standards and construction details for all public facility improvements. Section 14-105 Authorization for Idoptlon ofl ili"ls S,haoter The regulations contained in this Chapter have been adopted under the following authority: .:+.A.Chapter 212 - Municipal Regulation of Subdivisions and Property Development of the Texas Local Government Code, which authorizes a municipality to adopt rules governing plats and subdivisions of land within the municipality's jurisdiction. ~.B.Chapter 51 - General Powers of Municipalities of the Texas Local Government Code, which authorizes a municipality to adopt ordinances, rules, or police regulations that are for the good government, peace, or the trade and commerce of the municipality. a.c. The Home Rule Charter of the City of Colleyville, which authorizes the City Council to exercise all powers granted to municipalities by the Constitution or the laws of the State of Texas. Section 14-110 Applicability 01 Ihis Chapter The provisions of this Chapter shall be applicable to all public improvements owned and maintained by the City of Colleyville and to any semi-public improvements owned and maintained by a property owner's association that are intended to serve and function as a public improvement. Section 14-115 Variances and Appeals A. The Director of Public Servi€l9~ Works may consider an alternative proposal of a regulation contained in this Chapter in order to achieve the best overall design. When considering such a proposal, the Director of Public Ser\'i€le~ Works shall determine that the approval, disapproval or modification will not be detrimental to the public safety, health, or welfare or injurious to other property and is consistent with sound engineering practices. The applicant shall provide information to support a claim that the public interest may be better served by an alternative proposal. B. Any person seeking approval of a development may appeal a decision of the Director of Public S8P:i€l8s Works regarding the regulations contained in this Chapter by using the procedures described in Chapter 1 - General Provisions of this Land Development Code. Section 14-120 General Conditions i ,II"~ " H.5.A "COG &. TXDOT" SPECIFIC.~.TIONS A. "COG" and "TXDOT" Specifications - All drawings and details contained in Chapter 15 - Public Works Construction Details which include references to "item numbers", "specs" and "types" shall be governed by the latest version of "Standard Specifications for Public Works Construction, North Central Texas" of the North Central Texas Council of Governments ("COG"), with all amendments thereto, and shall Chapter 14 - Engineering Design Standards Page 14 - 1 Colleyvi/le, Texas, Land Development Code constitute the technical specifications, except as amended by this Land Development Code, and made a part thereof, but not physically bound within this document. Streets shall be designed in accordance with the most current edition of The Texas Department of Transportation's Highway Design Division Operations and Procedures Manual, AASHTO's A Policv on Geometric Desiqn of Hiqhwavs and Streets. and the Transporation Research Board's Hiqhwav Capacity Manual. 14.5.~ ^CCE!PT.~~JCE! OF IMPROVE!ME!~JTS B. Acceptance of Improvements - No public improvements shall be accepted by the City or its representatives, unless and until such improvements conform to this Land Development Code and all other applicable standards as prescribed by the City of Colleyville. All streets, alleys, sidewalks, drainage-ways, siqnaqe. water and sewer lines and all other public improvements shall be designed, placed and constructed in accordance with the design criteria contained in this Land Development Code. H.5.C PL.I\P'j RE)}IE'}'.' AND INSPECTIOP'j FEES C. Plan Review and Inspection Fees - Prior to the acceptance by the City of any public improvements, the developer shall pay the City a plan review fee and an inspection fee as follows: a..1.P\;IQli€J 'P.'@rks Enaineerina Plan Review Fee - 2% of the actual cost of the public improvements 9.2. P\;IQli€J 'fI.'erl(s Enqineerina Inspection Fee - 3% of the actual cost of the public improvements 14.5.D CITY DEt'ELOPER ^GREEME~jTS D. City-Developer Aqreements 1. Requirement amil \(l.<ai\'sr P."'fiJ':isffm - When it is proposed that the City will share in the costs with a developer for the construction of public improvements. no Ne public improvements shall be constructed within a development, unless and until a City-Developer Agreement has been approved by the City Council. Where the public improvements are a requirement of a subdivision plat approval. the +Re City-Developer Agreement shall be submitted to the City Council for approval by the City Council at the same time as the ~ Plat plat submittal, or as soon thereafter as practical. \,\..'l;1e~El Re p\;lQli€J parti€JipatieR ef p\;lQli€l fa€lilities is prepeseel aRel '.'Jl;1er8 tl;18 Qi~e€Jter ef P\;IQli€J Ser\'i€les Ras FRaele re€JeFRFR8RaatieR t@ tl;1e appre'/iR~ Qeay ef a €Ie'.'elepFR8Rt tl;1at Re City Oevelep8r 1'.~reeFReRt is R8€J9ssap/, tRe City Qeveleper ^~reeFReRt FRay Qe waivea. (0-00-1261 /12/19/00) 2. City Participation - The City may share in the costs with a developer for constructing public improvements relating to a development, provided a City-Developer Agreement has been approved QY elR ereliRelR€J9 tl;1at l;1as Qrile:m aaepteel by the City Council in accordance with this Section. The limits of City participation shall be expressly established in the agreement at a level not to exceed thirty (30) percent of the total contract price. Under the agreement, the developer shall construct the public improvements and the City shall participate in the costs. Where a developer is requesting City participation in the construction of a public facility and the total participation cost by the City exceeds fiftS8A tI;1S\;ISBAa ($15,000) twenty-five thousand ($25.000J dollars, the procurement procedures specified in the Texas Local Government Code for public improvements shall be used by the developer. All records to the developer's cost of constructing the public improvements shall be maintained and made available for inspection by the City. (0-00-1261/12/19/00) 3. Construction Plans - It shall be the responsibility of the developer's engineer to prepare all engineering construction plans and contract documents for construction of the project for the use of the City and the contractor. (0-00-1261/12/19/00) 4. Performance Bond - Where a City-Developer Agreement has been authorized, the developer shall execute a performance bond for the construction of the public improvements which shall include any City participation to ensure their completion. (0-00-1261/12/19/00) E. Authorization to Proceed - Chapter 14 - Engineering Design Standards Page 14 - 2 Colleyville, Texas, Land Development Code i. /1.l:IthfJ."''':lstfBf-I tB RI';f)see€/ QR rsr9je€t~ R@t r9€ll;lifiR!1j a City Develerser ^!1jr88~eRt, the The developer may proceed with the construction of the public improvements after the City has issued a letter authorizing the developer to proceed with the construction, provided the engineering construction plans have been approved by the Director of Public ~ervi€es Works. All construction shall be in accordance with the applicable sections of this Land Development Code. The developer may select his own contractor subject to the contractor executing the necessary bonds with the City and payment of the inspection fees required for each portion of the public facilities. (0-00-1261/12/19/00) Section 14.125 Construction Plan Requirements The purpose of this Section is to specifv the minimum construction drawinQ requirements for all public improvement projects. includinQ public improvements associated with a proposed subdivision or commercial development. All construction plans for public water, sanitary sewer, street, drainage and traffic improvements shall be designed, signed, sealed, and dated by a Registered Professional Engineer licensed in the State of Texas. aRE;! aE;!Rsre te tREl re€ll;lire~9Rts sf tRis ~eetisR. All construction plans or drawings must be accompanied by a Geotech Report signed, sealed, and dated by a Registered Professional Engineer licensed in the State of Texas. Plans and drawings shall adhere to the requirements in this Section and be furnished in the fellewiR!1j format GlR8 eeRtaiR tRe 9Ie~eRt~ listed herein: A. General Requirement - No construction of anv public improvement shall commence. unless and until the construction plans for the proposed public improvement has been approved bv the Director of Public Works or desiQnee. B. Number of Copies - The developer. or developer's engineer. shall submit the minimum number of copies required bv the Director of Public Works to distribute to the various Citv departments to adeQuatelv review the proposed improvements. 4.C.Cover Sheet a.1- project title 9.g property legal description, if applicable G.J.. ~ citv name G.~. vicinity map 8.5. owner, engineer, and surveyor name, address and telephone number f. ~. project title in small print placed vertically along the right border ~.Z. sheet index R.~. signature block for City approval 2.D.Copv of Current Plat - When construction plans are related to a new subdivision or a commercial development,arsrslieaele, a copy of the current plat shall be bound with the construction plans. The signed plat shall be bound with the as-built drawings. 3.g.Drainaqe Area Map - The drainaQe area map is critical to all drainage desiQns. since the ultimate lavout. sizing and hvdraulic analvsis is dependent upon a thorouQh review of the proposed development. This map should be accompanied with all drainage calculations. The Drainage Area Map must show the phvsical features of the site that either exist or are proposed. including aU the existing and proposed contours, existing and proposed storm sewers, and/or other drainage facilities. Commercial projects should include the locations of buildinQs. flatwork and pavement. 4.E.Site Plan - The developer of a commercial project shall submit a site plan indicating the location and width of all proposed and existing street and driveway approaches noting the back-of-curb radii. i.G.Utilitv Plan - This drawinQ shall indicate iR8ieatiR!1j the location and size of all existing and proposed water and sanitary sewer lines with adjacent existing or proposed top of curb grades. A*;e s~how the location of all existing and proposed fire hydrants adjacent to the site including the maximum coverage radius of each as outlined in later sections of this manual. i.H.Plan and Profile Sheets - Plan and profile drawinQs shall be required for roads, sewers, storm sewers, Chapter 14 - Engineering Design Standards Page 14 - 3 Colleyville, Texas, wnd Development Code channels, flumes, and water lines twelve (12") inches in diameter and larger. Stationing shall be generally left to right and with stationing beginning at the downstream end for all sewers, storm sewers, and channels. Stationing shall be included on the plan view as well as the profile for all roads, water, sewer, storm sewer and channel sheets. Elevations shall be calculated and provided iA on all profiles as indicated below. a.1- Straight grade - provide elevations at a maximum interval of 50 feet. 9.~. Vertical curve - provide elevations at the beginning and ending points and at a maximum interval of 25 feet in between. +:.I.Plan & Profile Sheet Size - Plan and profile sheets shall not exceed twenty-four (24") inches wide by thirty- six (36") inches long. Horizontal scale shall be one (1") inch equals fifty (50') feet or larger, i.e. 1" = 40'. Vertical scale shall be one (1") inch equals five (5') feet or larger. i.J.Details - Drawina details shall be included with all construction olans to clarifv orooosed construction soecifications and said details shall be consistent with Chaoter 15 of this Land Deve/ooment Code. fer im~FevemEH:Jt~ ~re~e~e€! fer €!e€!iQati@A te tRe City. 9.K.Plottinq Drainaqe Features - Appropriate hydraulic grade line or water surface profile shall be plotted with all drainage designs. Capacity, design discharge, velocity, and velocity head shall be noted on each segment of a drainage facility in the profile whenever one or more of these parameters changes. 4G.L.Erosion Control Plan - The developer of a subdivision or a commercial project shall submit an erosion control plan in accordance with the requirements of Chapter 12 - Erosion Control. M. Storm Water Pollution Prevention Plan - The deve/ooer of a subdivision or a commercial oroiect shall submit a storm water oollution orevention olan in accordance with the requirements of the Texas Commission on Environmental Qualitv. ~.N.Street Sian Plan - showina the location of all prooosed street name sians and traffic control sians. The street sian olan shall include an elevation view of each street sian indicatina the tvoe and color of each siqn. All sians shall complv with the requirements of the latest edition of the Texas Manual on Uniform Traffic Control Devices. Refer to street sian standards. located elsewhere in this Land Development Code (Section 14-145). ~.O.Citv Review and Approval Process - CemitnH.tieA ~1:;Jj:J~ ~!:lall ee reviewe€! BY t!:l9 City GlR€!, after all €lemFFleRts Ra'/e BeeR Fla~@I\'e€!, &i~Re€! B} tRe gireQter ef P~Bli€l Sep{i€le~. CeR&tr~€ltieR m~st staR v:it!:liR eRe (1) year fellevJiR~ t!:le City'~ a~~re'/al. PlaRs fer I'lF@jQQt~ '/JRiQR !:la'le Ret starte€! QeR&tr~€ltieR witRiR tRi~ time ~erie€! m~st Be s~Bmitte€! te tRe City fer aRe....: revis'I:. All construction plans for public improvements shall be reviewed bv city staff for compliance with this Section and with any aoplicable Quidelines of other aaencies. City staff shall provide written comments to the develooer and the developer shall resoond to all city comments. The Director of Public Works. or desiQnee. shall not aporove any construction olans until all comments have been resolved and the construction plans determined to be acceptable to the city. All aoproved construction plans shall be sianed bv the Director of Public Works. or desianee. and no construction work shall commence until a ore-construction meetinQ has been held and a letter of authorization to proceed has been issued bv the Director of Public Works. or desianee. Development oroiects which have not started within one year from the date of approval of the construction plans shall require a new review. Section 14.130 Street Design Criteria 14.S.A RIGHT OF '_~_(AY 'A'IDTHS A. Riqht-of-Wav Widths - The right-of-way widths for any proposed street shall be designed for the intended use and anticipated traffic volume at optimum development of the area served. Additional right-of-way may be required at street intersections and to provide for left and right turn lanes at high-volume intersections. The following table shall be used as a guide in determining right-of-way widths. Chapter 14 - Engineering Design Standards Page 14 - 4 Colleyville, Texas, Land Development Code Local R2U 50 (2) 15 30 2 Cul-de-sac R2U 50 (3) 18 36 (3) 2 Minor Collector C2U 75 12 42 2 wI 9' parking or 3 wlo arkin Major Collector (two lane) C3U 75 12 42 2 wI 9' parking or 3 wlo arkin Major Collector (four lane) C4U 80 12 48 4 undivided Minor Arterial M4D 95 13 52 4 divided P4D 120 13 52 4 divided P6D 120 12 76 6 divided (1) Street classification refers to the functional classification shown on the Master Thoroughfare Plan. (2) A local street having a total length in excess of one thousand two hundred (1,200) feet or serving more than thirty (30) dwelling units may be required to provide a right-of-way width of not less than sixty (60) feet. (3) A cul-de-sac street exceeding 600 feet in length shall have a 56' right-of-way and 36' of pavement. H.&.B DESIGN SPEED .A.ND M.~.XIMUM GR~.DE B. Desiqn Speed and Maximum Grade - All streets shall be designed to conform to the following parameters: mm~.Q....._.__m.m..._ 30 One lane or center 12' .............................~.... .................................................. .............................,...................... ......................................................................H ...................................._.H. Arterial 40 j 4 0.5 lOne lane in each direction (1) The Director of Public ~ Works may approve an alternate design. Section 14-135 Driveway Spacing and Design Standards C. Drh'e.t:ay Spaeing and Design Standards A. Residential Construction - Residential driveway approaches shall be constructed of six (6") inch thick three thousand (2,000) five hundred (3.500) psi compressive strength concrete reinforced with #3 steel bars on eighteen (18") inch centers each way, with #4 bars doweled into the existinq concrete pavinQ. Residential driveways shall be constructed with the return curbs having a rolled face disappearing at the sidewalk and joining the street curb. B. Commercial and Industrial Construction - Commercial and industrial driveway approaches shall be constructed of six (6") inch thick three thousand (2,000) five hundred (3.500) psi compressive strength concrete reinforced with #do #4 steel bars on eighteen (18") inch centers each way, with #4 bars doweled Chapter 14 - Engineering Design Standards Page 14 - 5 CoJ/eyvilfe, Texas, Land Development Code into the existinq concrete pavinq. Commercial and industrial driveways shall be constructed with the return curbs having a rolled face disappearing at the sidewalk and joining the street curb. C. Driveway Approach Depth - The driveway shall begin at the street curb and extend to the property line or to a point nine and one-half (9.5') feet from the back of the curb, whichever is greater. The drive approach shall be constructed such that the height of the drive approach at the property ROW, with a ~ tvpical nine and one-half (9.5') foot parkway, shall be two and one-half (2-1/2") inches higher than the top of the curb. The tanqencv point of a driveway curb shall be a minimum of ten (10) feet from a storm water inlet. D. Driveway Approach Widths and Spacinq - The criteria contained in the following table shall be the minimum and/or maximum standards to be applied in spacing and designing driveways on public streets. For the purpose of this regulation, driveway width GlF-l61 s~GlsiF-lg shall be measured at the property line. The Director of Public Ser:vises Works may modify these standards based on anticipated traffic flow and in accordance with sound traffic engineering practices. To implement the standards contained in the followinq table. subdivision plats for new commercial developments shall be required to provide cross-access easements. Driveway Spacing (centerline) Local 25' ..................................................... ........~. m.. ..... ...............j...... Minor Call. 25' 35' ............................... ........... .....................~ ......................M....r ........ .................. .............................. ........................... !I\11Cij()r(:;()II, .......,.....,..,..'..'mmmmmm;m'm' ",.,,??:,; 35' i Arterialmmmmm??,:"",}5' ~()c;CiI,., .,..,..,..,..".,..,..,..,'.".'m' ".'..'.mm. m'."..'m.'.'..,..,....,.!9..,. ,. 20' inor CoI1.1Q'm.+ 20' 1 O'mJ?Q'.m .. ..mm .,mm ."'."m?Q:'m}Q.'.. 100' 100' Driveway Curb Radius Minimum Distance from Driveway to Intersection (0; to oi) E. Provision for Joint Approaches - Driveway approaches shall be located entirely within the frontage of the premises they serve except that joint, or cooperative, driveways with adjoining property holders may be permitted by the Director of Public Sevvises Works. When a joint drive approach is proposed by a developer, the request must be made by all interested parties and/or all property owners involved. F. Circular Drivewav Approaches at Street Intersections - The Director of Public 5ervi"8~ Works may approve a circular drive on a corner lot where both streets are residentially classified. G. Anqle of Driveway Approach - The angle of the driveway approach with the curb line shall be ninety (90) degrees. H. Sidewalk to be Removed - Where a driveway approach is to be built, any existing sidewalk located within the proposed driveway location shall be removed and the entire area replaced as a driveway. The drive approach shall extend to the property line. ~.I. Driveways Crossinq Bar Ditches Chapter 14 - Engineering Design Standards Page 14 - 6 Colleyville, Texas, Land Development Code a..1", The minimum culvert pipe size shall be 18" diameter. However, an engineered design that provides for a larger culvert pipe size may be required by the developer where the Director of Public S8~i@8S Works determines that additional drainage capacity may be required. The ends of all culvert pipes shall be cut at a 6: 1 slope. 9. 2.Radius: Driveways shall be constructed with the return curbs joining the edge of pavement at the street with a minimum ten-foot (10') radius. @.LThe maximum slope from the edge of driveway to the top of the culvert pipe shall be 6: 1. The sloped area around the end of the culvert pipe shall be sodded or hydro-mulched to resist erosion. G.4. The minimum cross slope on the drive shall be 1/8 inch per foot. the minimum longitudinal slope between the edge of pavement at the street and the valley over the culvert pipe shall be 1/4 inch per foot. Q.~Future maintenance of the drive approach and culvert pipe is the responsibility of the property owner. f. 6.During the drive approach installation, all ditch grading upstream and downstream of the proposed driveway culvert is the responsibility of the property owner. a.J. General a..1",Driveway Approaches at Pedestrian Crossings: Driveway approaches shall not be located in street intersections or at established pedestrian crossings. 9.2. Driveway Approaches at Obstructions: Driveways shall be kept at a minimum of five (5') feet away from obstructions such as street light posts, fire hydrants, traffic signals, etc. G..l:,Accumulative Width of Approaches: Driveway approaches shall not occupy more than forty (40%) percent of the frontage of a lot or tract. Section 14-137 Fire Lane Requirements (2000 IFe Section 503) A. Plan Approval- Plans for fire lanes shall be submitted to the Fire Marshal Division for review and approval prior to construction. RepaintinQ of existinq markinQs does not require plan review unless chanQes are to be made. B. Obstructions Prohibited - Fire lanes shall be kept clear and unobstructed at all times. MarkinQ shall be repainted as necessary to maintain readabilitv. C. SionaQe - Where required bv the Fire Marshal. approved siQns or other approved notices shall be provided and maintained to identify fire lanes and prohibit obstructions. D. Where Required - Fire lanes shall be provided when any portion of the facilitv or any portion of an exterior wall of the first stOry of the buildinQ is located more than 150 feet from fire apparatus access as measured bv an approved route around the exterior of the buildinQ or facilitv. E. Certain Roadways Not Considered Access - Heavily traveled public roadways are not considered for fire apparatus access due to the danQers involved with operatinQ fire apparatus in close proximity to movinQ traffic. F. Access To Serve All BuildinQs - Fire lanes shall be provided to serve all buildinQs throuQh parkino areas to service entrances. loadinq areas. trash collection areas. and other areas deemed necessary to be available to fire and emerQencv vehicles. G. Drivewavs Included - Fire lanes shall include driveways leadinq onto a public street. Chapter 14 - Engineering Design Standards Page 14 - 7 Colleyvil/e, Texas, Land Development Code H. Fire Lane Width - Fire lanes shall have an unobstructed width of not less than 24 feet and an unobstructed vertical clearance of not less than 14 feet. I. Turning Radius - Fire lanes shall have a minimum inside turnina radius of thirty (30) feet and a minimum outside turnina radius of fifty (50) feet. J. All-weather Surface ReQuired - Fire lanes shall be desianed and maintained to support the imposed loads of fire apparatus and shall be provided with an asphalt or concrete surface so as to provide all-weather drivina capabilities. K. Construction Specifications - Fire lanes shall be constructed of seven (7) inch concrete with #3 rebar on eiahteen (18) inch centers on chairs over a modified subarade as per the Geotechnical Soils Report: or seven (7) inch asphalt over a modified subarade as per the Geotechnical Soils Report. The construction shall be capable of supportinQ a minimum of 65.000 pounds gross vehicle weight. L. Maximum Dead-end Lenath - Dead end fire lanes in excess of 150 feet in lenath shall be provided with an approved area for turnina around fire apparatus. Dead end fire lanes more than 150 feet in lenQth but less than 700 feet in lenath shall provide one of the followinQ turn-around confiaurations. Dead end fire lanes in excess of 700 feet in lenath shall be submitted to the Fire Marshal for review and approval. 30'R TYP. 24' --. .- ~ +-24' 100' DIAMETER CUL-DE-SAC ACCEPTABLE ALTERNATIVE TO 120' HAMMERHEAD .. 24' ~~R\ "70'. . 70' t I~I~I 24~ .. "24' 120' HAMMERHEAD ACCEPTABLE ALTERNATIVE TO 120' HAMMERHEAD M. Fire Lane Striping - Fire lanes shall be marked with a six (6) inch wide continuous briaht red stripe on both sides. Striping shall be on the curb face where curbina is located at the edae of fire lanes. White 4 inch hiah letterina with a one (1) inch stroke centered on red stripe shall read: NO PARKING - FIRE LANE. This letterinQ shall be painted every (15) feet measured from the end of one letterina aroup to the beainnina of the next aroup with a one (1) foot space between "No Parkina" and "Fire Lane". Red paint shall not be used for any parking lot markina other than fire lanes. Fire lane markinas are subiect to the field inspection of the Fire Marshal. Chapter 14 - Engineering Design Standards Page 14 - 8 Colleyville, Texas, Lmd Development Code Section 14-140 Street Improvement Specifications A. General - Streets shall be constructed or reconstructed using either hot-mixed asphaltic concrete pavement sections or reinforced portland cement concrete pavement sections that meet or exceed the minimum specifications of this Land Development Code. The developer requiring street construction shall provide a geotechnical report, sealed by a Registered Professional Engineer licensed in the State of Texas, containing recommendations for subgrade thickness and content. The minimum subgrade and pavement thickness shall be in accordance with the specifications contained in this Section. For the purpose of this Section, a collector street shall be defined as all those collector streets shown on the Master Thoroughfare Plan and those streets internal to a subdivision which provide connection between local residential streets and the major collector network and which are designed to accommodate more than 500 vehicles per day. AS. Hot-Mixed Asphaltic Concrete Pavement Sections 1. Local Streets (including cul-de-sac) a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Five (5") inches Type "A" or "B" hot-mixed asphaltic concrete placed in three (3) lifts. The bottom lift shall extend to one (1 ') foot beyond the back of curb line. d. Two (2") inches Type "0" hot-mixed asphaltic concrete placed in one (1) lift. 2. Collector Streets a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Six (6") inches Type "A" or "B" hot-mixed asphaltic concrete placed in three (3) lifts. The bottom lift shall extend to one (1 ') foot beyond the back of curb line. d. Two (2") inches Type "0" hot-mixed asphaltic concrete placed in one (1) lift. 3. Arterial Streets a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Eight (8") inches Type "A" or "B" hot-mixed asphaltic concrete placed in four (4) lifts. The bottom two lifts shall extend to one (1 ') foot beyond the back of curb line. d. Two (2") inches Type "0" hot-mixed asphaltic concrete placed in one (1) lift. 4. Stabilized Subgrade for Hot-Mixed Asphaltic Concrete Pavements The basic design of the asphaltic pavement sections for streets and roads assumes average subgrade conditions which in all cases shall be stabilized to not less than the thickness shown herein with lime or cement at a minimum rate of 6% of the necessary volume or that recommended by an approved and acceptable geotechnical report submitted to the City by iaFl Glssre€lite€l a licensed Geotech Engineer. Classification of the subgrade for evaluating the supporting qualities shall generally apply to the top twelve (12") inch layer of soil measured down from subgrade surface. Where combinations of conditions indicate special problems, such as springs or seepage, drastic material changes from point to point, etc., that reduce the existing subgrade below average, appropriate remedies designed by a Registered Professional Engineer based upon actual onsite observations and tests shall be included to correct the particular condition involved. In all cases, the requirements set forth in this criteria are minimum and the City reserves the right to require further additional testing (such as California Bearing Ratio), precautions or treatments consistent with sound engineering practice when necessary to provide for other conditions not specifically covered by this criteria. Compaction of stabilized subgrade shall be 95% standard proctor density. Chapter 14 - Engineering Design Standards Page 14 - 9 Col/eyville, Texas, Land Development Code 14.S.Q .C.Reinforced Portland Cement Concrete Pavement Sections 1. Local Streets (including cul-de-sac)~ a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Six (6") inch thick portland cement concrete, reinforced with #3 reinforcing bars having a spacing of eighteen (18") inches center to center both ways. 2. Collector Streets;. a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Seven (7") inch thick portland cement concrete, reinforced with #4 reinforcing bars having a spacing of eighteen (18") inches center to center both ways. 3. Arlerial Streets~ a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Eight (8") inch thick portland cement concrete, reinforced with #4 reinforcing bars having a spacing of eighteen (18") inches center to center both ways. 4. Basic Requirements For All Reinforced Concrete Pavement - The basic design of reinforced concrete pavement sections for streets and roads assumes poor subgrade conditions which shall be stabilized with lime or cement at a minimum rate of 6% of the necessary volume or that recommended by an approved and acceptable geotechnical report submitted to the City by 3R 6lGGreaitea a licensed Geotech Engineer. In all cases, the requirements set forth in this criteria are minimum and the City reserves the right to require further additional testing (such as California Searing Ratio), precautions or treatments, when necessary, consistent with sound engineering practice to provide for other conditions not specifically covered by this criteria. 5. Concrete for Pavement - Concrete for pavements shall be Class "A" and consist of five (5) sacks (minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural strength of five hundred pounds per square inch (500 PSI) and a twenty-eight (28) day compressive strength of three thousand five hundred pounds per square inch ~ 3.500 PSI). Composition and placement of reinforced concrete pavements shall be in accordance with the applicable requirements of Item 364 of the Texas State Deparlment of Transporlation Standard Specifications. Coarse aggregate shall be either number 2 or 3. Cement for the mixture shall be Type I portland cement. All hand pours are to be six (6) sacks minimum of portland cement for each cubic yard of concrete mix with a compressive strength of three thousand five hundred pounds per square inch (3,500 PSI). ~.D.Curb and Gutter Specifications All streets shall be provided with reinforced portland cement concrete curbs and gutters in accordance with the following specifications. 1 . Curbs and gutters~ a. Curb rolls shall be six (6") inches wide and not less than six (6") inches high nor more than seven (7") inches high,: b. Curb and gutter bases shall not be less than twenty-four (24") inches wide and provide a minimum gutter width of eighteen (18") inches (see detail P-4A and P-4B)~ c. Gutter depths for hot-mixed asphaltic concrete pavement shall be five (5") inches for local streets and six (6") inches for collector and arterial streets. Gutter depths for reinforced portland cement concrete pavement shall be the same as the pavement thickness. Chapter 14 - Engineering Design Standards Page 14 -10 COlleyvi/le, Texas, Land Development Code 2. Reinforcement Steel - Reinforcement shall be provided by three (3) number three (#3) steel reinforcing bars by placing one (1) bar in the curb roll and two (2) bars in the curb and gutter base. This reinforcement is in addition to reinforcement in portland cement concrete pavements. 3. Concrete Classification - Concrete for curbs and gutters shall be Class "A" and consist of five (5) sacks (minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural strength of five hundred pounds per square inch (500 PSI) and a twenty-eight (28) day compressive strength of three thousand five hundred pounds per square inch (~ 3.500 PSI). 4. Installation Procedure - Curb and gutter for hot-mixed asphaltic concrete pavements shall be placed on the first two (2") inch lift of asphaltic paving. For reinforced portland cement concrete pavements, the curb and gutter base shall be placed monolithically with the pavement. The curb roll shall be placed monolithically with the pavement or added separately. Curb rolls added separately shall be provided with number three (#3) reinforcing bar stirrups spaced twenty-four (24") inches center to center which extend to within three (3") inches of the bottom of the pavement. 5. Driveway Cuts - All driveway entrances constructed in existing curb and gutters shall be saw-cut at the curb return on both sides of the driveway and eighteen (18") inches into the street. After work is completed, the street sidewalk shall be repaired and it shall be the responsibility of the party installing the driveway. 44,.gQ.F. Street Drainaqe - The following drainage conditions shall be observed: 1. All roads shall be a crowned or roof top section so as to provide proper drainage. 2. All plats shall depict the flow of drainage with arrows sufficient to show predicted path. 3. An explanation and depiction shall be attached to show outflow and inflow availability on high flow areas. Adjoining property where inflow originates or outflow exists must be attached to insure compliance with drainage or excessive run-off factors. 4. No plat shall be considered for approval unless accompanied by a complete set of construction drawings that show the drainage areas and flow calculations. 5. The contractor/developer will assume all responsibility to disperse excess run-off so as not to exceed previous disbursements to the satisfaction of the city. ~.G.Street Construction 1. The street portion of the plat must be approved by the Planning and Zoning Commission or the Approving Body, Fire Chief, Police Chief and Director of Public Works SePliG8s. 2. The street type code must be plainly visible on the plat and marked so that no misunderstanding can result. 3. A performance bond must be presented to the City Secretary or duly appointed representative for an amount equal to the contract by the contractor doing the project. A maintenance bond equal to 10% of the contract price will be in effect for two (2) years after acceptance by the City. 4. No work shall commence without the issuance of an authorization of construction letter. 5. When Perimeter Street Escrows are required the following items shall be included in the fee calculations. a. Paving b. Subgrade stabilization c. Curb and gutter Chapter 14 - Engineering Design Standards Page 14 - 11 Colleyville, Texas, Land Development Code d. Sidewalk (or pathways where applicable) e. Excavation f. Utility relocation (20% of paving) g. Storm sewer improvements (20% of paving) h. Engineering (12% of the total of items a - g) i. Contingency (15% of the total of items a - h) 11.8.F STREETS T8 DE TRENCHED H. Streets to be Trenched - When a G+ty public street is cut or trenched, the street wiU shall be repaired according to this paragraph. A three (3) sack per cubic yard concrete mixture wiU shall be filled-in beginning one (1 ') foot above the object the street was cut for and continue until one (1 ') foot from the top of the street or reaching the plane of the sub-base compacted to 95% MeG;jifiee Standard Proctor. The base and topping wiU shall be the minimum required for that type of street. 11.S.C Y8RFEITURE C1..'.{"JSE I. Forfeiture Clause - Iff in the opinion of the Director of Public SePliQ9& Works'i' or his duly appointed representative, the street project does not comply with the type code applied to the street(s), the performance bond wiU shall be forfeited to the amount necessary to correct the substandard section if that section(s) is not corrected by the contractor. 1. All areas in question by the City that cannot be reconciled by the contractor will be examined by an independent testing firm, agreed upon by both parties, and its findings will prevail. 2. The cost of this testing will be borne by the incorrect party. 3. The City of colleyville reserves the right to make tests or checks at any place or any time there is a question of ordinance compliance. 4. Any developer or contractor found to willfully and knowingly misrepresent or disregard the regulations herein stated shall forfeit all rights and permits in the City of Colleyville, Texas, with a majority vote of the City Council. 11.B.II TEKUJ l}EV:.RnfENT OF IImuv::.Y S"ECIFIC.'i.-'fI8NS J. Texas Department of Transportation HiClhwav Specifications - All specifications not specifically provided for elsewhere in this Chapter are referenced to the Texas State Department of Transportation Standard Specifications For Construction of Highways, Streets and Bridges, 1993, AASHTO's A Policv on Geometric DesiCln of HiClhwavs and Streets. and the Transporation Research Board's Hiqhwav Capacity Manual. 1. Item 260 Lime Treated Subgrade - Lime used shall be Type "A" hydrated lime. The placement and construction of the subgrade shall be done in accordance with the applicable requirements described in Item 260 of the Texas State Department of Transportation Standard Specifications. 2. Item 270 Cement Treated Subgrade - Cement used shall be Type 1 portland cement. The placement and construction of cement treated subgrade shall be done in accordance with the applicable requirements described in Item 270 of the Texas State Department of Transportation Standard Specifications. An asphaltic membrane of RC-250 asphalt shall be applied as a cure coat. An alternate method of wet curing is also acceptable. 3. Item 310 Prime Coat - Asphalt material for prime coat shall be EA-HVMS. The placement of prime coat shall be described in Item 310 of the Texas State Department of Transportation Standard Specifications. Prime coat shall be placed on all lime treated subgrade at a rate of not less than 0.15 nor more than 0.25 gallons per square yard. Chapter 14 - Engineering Design Standards Page 14 - 12 ColleyviJ/e, Texas, Land Development Code 4. Item 340 Hot-Mixed Asphaltic Concrete Pavement - The composition and placement of hot-mixed asphaltic concrete pavement shall be in accordance with the applicable requirements of Item 340 of the Texas State Department of Transportation Standard Specifications. The asphalt for paving mixture shall be AC-20 forming from 4.5 to 6.0 percent of the mixture by weight. The asphalt for use as a tack coat under Item 340 shall be either RC-250 or EA-HVRS. 1 UtI CQl>)CRETE PIPE K. Concrete Pipe - All concrete pipe used for drainage purpose on City streets shall be reinforced. 11.8.J l.IME TRE!.-TEQ SlJD€;R,\.QE L. Lime Treated Subqrade - Lime treatment shall extend ten (10') feet, if feasible, beyond the completed street when a future street is proposed to be built to assure proper conformity. Section 14-145 Street Signs and Traffic Control Signs A. General Reauirement - Street name siqns and traffic control sians shall be reauired for all street intersections. Installation of siqns shall be performed bv City work crews after payment to the City has been received from the developer for the installation costs. The Director of Public Works shall provide the developer with a cost estimate for all siqns associated with a development. The cost estimate shall include material and labor costs. 1. The Director of Public Works may reauire the installation of temporary street name siqns bv the developer. 44.9A.B.Location - Street si~Rs &R;II ge &ix (9") iFl€R8& extrl;lGleGl, Ra'/s wRits lett8riR~ eR ; 911;113 9a€ik~reI;lFlGl, 138 8R~iFlser ~raGl9 refle€iterizeGl, aRGl iR€illolGle tRe ele€l{ Fllol~eer& aleFl~ witR tR9 street Fla~8. Street &i~R& ~Rallee flolrRisRsGl aRGl iFl€talleGl 9)' tRe &1;I9Gli';iGler fer all iFltsr&s€tieFls \.:itRiFl er a9101ttiFl~ tI;Je sl;Ie;i:.icj~Fl. All signs shall be located in accordance with the Texas Manual on Uniform Traffic Control Devices. 14.Q.S SigR& C.Standards - All signs shall conform to the standards as set forth in the Texas Manual on Uniform Traffic Control Devices. All road identification signs are to have a blue background with tf;:Jree (J) +ooR white reflective lettering. 44.Q...G.D.lnstallation - The sign pole shall be buried to a minimum depth of two (2') feet and placed in a twelve (12") inch diameter concrete filled posthole. The pole shall be tall enough to accommodate all applicable signs. The bottom of tR8 ste~ all sign~ shall be located seven (7') feet above the finished grade of the €loIfrsl;IFlGliFlg ~relolFlGl travel surface. ~.E.Approval - The developer shall submit a list of signs to be placed and a graphical representation of the signs for review by City E:F1giFleer Director of Public Works prior to installation. F. Custom Siqns - The Director of Public Works may approve custom-made street sians and custom-made sian poles. provided the Director of Public Works has executed a written aareement with a party responsible for the maintenance and replacement of such siqns or siqn poles. Section 14-150 Sidewalk & Pathways Specifications H.I0.A SIQEV,'!.U( SPECIFIC}. TIQl>)S 4-.~.Permit Reauired - No person shall construct, reconstruct, alter, repair, remove or replace any sidewalk Q! pathway on any public property within the City Limits without first obtaining a permit from the building permit office, unless the sidewalk or pathway is included on the construction plans of an existinq approved permit. Chapter 14 - Engineering Design Standards Page 14 - 13 COlIeyvilIe, Texas, Land Development Code ~.B.Maintenance Bond - No such permit shall be approved until proof of bonding coverage has been submitted to the City and a two (2) year maintenance bond in the amount of 10% of the total cost of construction covering the sidewalk or pathway is in full force and effect at the time of the permit approval. Such bond shall not be valid unless persons doing the work are covered by the bond. Such bond may cover other work done by the applicant. The Director of Public Works Citj IiR!ijiREler may waive the maintenance bond requirement for repair to an existing sidewalk or pathway. ~.C.lnsDection Required - All work done in construction, reconstruction, alteration, repair, or removal or replacement of sidewalks or pathways shall be inspected by the city inspector to assure compliance with these regulations. When other public improvements are required, final acceptance of all other improvements shall not be made until sidewalks or path wa VS are approved. Ii.IO.R SIBE'N.\hl( SPECIFIC:. TI91'1S 4.Q.Minimum Sidewalk or Pathway Width - All sidewalks shall be a minimum of four (4') feet in width, except a sidewalk located within or abutting a collector street, or larger, as shown on the Master Thoroughfare Plan, which shall not be less than five (5) feet in width. All sidewalks and pathways shall be constructed in the area between the curb or grade line of the public street and the abutting property line unless the pathway is situated within a dedicated pathway easement or riQht-of-wav. The edge of the sidewalk or pathway shall generally be parallel with the curb line and be situated no more than one (1') foot from the abutting property line. The Director of Public Works Ser/is8s may approve a plan to alter the location of a sidewalk to preseNe a tree or for aesthetic purposes. One additional foot of width shall be added to a sidewalk that abuts a street curb. The widths of all sidewalks and tf;aHs pathways shall be in accordance with the following table, which are further referenced in Chapter 15 - Public Works Construction Details. m.Ty'p~"~.~m.. ...m..Ty.PE:l...::.!3..':............ ....Typ~..'.'9~....... ....Typ!:l..'g:'...... .............................................._m T e"E" 4.0 fl. .............................................. 5.0 fl. "'ii:'(j""ff'" .........................N....... ................................................... 10.0 fl. m...12:ifft....-.. ~.E.Construction Materials - Sidewalks shall be constructed of portland cement concrete (minimum thickness four (4") inches). #a# Pathway system sidewalks shall be a minimum thickness of five (5") inches. Concrete for sidewalks and pathways shall be Class "A" and consist of five (5) sacks (minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural strength of 500 pounds per square inch (500 PSI) and twenty-eight (28) day compressive strength of 3,000 pounds per square inch (3,000 PSI). Reinforcement shall be in accordance with the construction detail contained in Chapter 15 - Public Works Construction Details. In such cases, reinforcements shall be #3 steel deformed reinforcing bars on eighteen (18") centers. a..F. Architectural Barriers Act - All sidewalk/street intersections shall be constructed so as to provide a ramp - that complies with the Architectural Barriers Act. Barrier free ramps shall be provided for access to the street. The following specifications shall apply: eLRamp to be minimum four (4') feet in width. 9.2. Ramp to be constructed with Class "A" concrete. G.3. Ramp concrete thickness shall be the same as the street (six (6") inch normal residential). €1.4. #3 bars shall be used for reinforcement (twenty-four (24") inch on centers). 8.S.curb return shall match existing curb height of the street and taper to the connecting walk with a 1- foot radius. f.6. Street shall be blocked out (max. twelve (12") inches) and dowels installed. r;;z. Saw joints shall be made one and a half (1 1/2") inch minimum depth and sealed with silicone joint sealant material. A.B. Subgrade shall be prepared to a minimum depth of six (6") inches. +'9. At no time shall the walk running parallel to the street be altered. j.10Surface of walk shall be coarse and ribbed to provide extra traction (see detail P-8). Chapter 14 - Engineering Design Standards Page 14 - 14 Colfeyville, Texas, Land Development Code Where the above specifications do not apply or have jurisdiction, refer to the specifications from the American Disabilities Act. Section 14~155 Street Lighting 11.11.A CENER.U. REBlHREl\1EI'IT 4-. A. General Reauirement - Street lights shall be installed at all intersections, at the end of all cul-de-sac streets, and at additional locations in accordance with the following table: At intervals of not more than three hundred 300 feet Wood or metal 1 00 watt high pressure sodium 30 feet ~B.Spacina - The number of required street lights shall be equal to the total linear footage between street intersections divided by the required spacing. Fractions of street lights shall be rounded to the next whole number. 3.C.lntervals - Street lights shall be placed at approximately equal intervals between intersections and shall be subject to the approval of the Director of Public Works €lily eR~iREl8r. 4.D.Desian - Cobra head lamps shall be provided on standard street lighting fixtures, except that other lamp types may be permitted where custom lighting is approved by the Director of Public Works ~ 8R~iRe9r. 11.11.B. CHSTQU 1.1GIITll'lfJ 4-. E. Custom Liahtina - The subdivider may elect to provide custom lighting lieu of the required standard street lighting, subject to the approval of the city engineer. ~F. Custom Liahtina Maintenance - If a subdivider elects to provide and install custom lighting, a homeowner's association (or some other such private entity) shall be created which will be perpetually liable for all costs associated with the maintenance of the lighting fixtures. Where the city is not liable for the costs of electrical energy from the custom lighting as provided in this subsection, the homeowner's association shall also be liable for the electrical energy costs of the custom lighting. Section 14-160 Water System Improvements 11.12.1. CE!\IER.\1> A. General - This section pertains to general design requirements for water distribution system construction in the City of COlleyville. All water lines shall be sized and designed in accordance with the City of Colleyville Water Distribution System Master Plan or as determined by the Director of Public Works SePiliG8s. In the absence of specific standards, all water supply, distribution, pumping, and storage improvements shall be designed in accordance with the most current standards of the American Water Works Association or the Standard Specifications for Public Works Construction of the North Central Texas Council of Governments or criteria adopted by the Texas Administrative Code, Chapter 290, "Water Hygiene". 44.42.8. Line Sizes & Locations 1. Standard water line sizes are, 8 inch, 10 inch, 12 inch, 16 inch, 20 inch, and 24 inch diameter. Other sizes may be approved by the Director of Public Works SElP/i€l8S. Chapter 14 - Engineering Design Standards Page 14 - 15 Colfeyville, Texas, Land Development Code 2. All water lines shall be looped. Dead end lines shall not exceed 600 feet, unless approved by the Director of Public Works Servi€les. No services shall be allowed on a dead end line. 3. Water lines shall be located within the parkway. Along State Highways, water lines are required on both sides of the roadway. New water lines crossing existing streets shall be placed by boring. A casing shall be required under major and minor collector roadways, arterial roadways and Highway 26 (Colleyville Blvd.). Open cut excavation will not be allowed to cross existing streets, unless approved by the Director of Public Works Servi€lEls. 4. Easements for water line construction shall meet the following requirements: a. The easement width shall be a minimum of 15 feet. b. In areas where multiple easements exist the easement may need to be wider as specified by the City. 5. All piping with mechanical couplings, push-on, or similar joints subject to internal pressure shall be designed with blocking, anchors, and restraining harnesses to preclude separation of joints. 6. Water lines for multi-family, commercial and industrial fire protection lines shall be dedicated to the public, unless the system is isolated from the public system by a detector check. All water lines shall be a minimum of eight (8") inches in diameter and looped when possible. Dead end lines shall not exceed 50 feet on multi-family, commercial, or industrial sites. All public water lines located on private property shall be centered in a 15-foot minimum easement. Larger easements may be required by the Director of Public Works SerVi€l9S to provide adequate space for maintenance. Water lines shall not be located under paved surfaces where possible. ~C. Line and FittinQ Materials- All water lines and fittings shall be new materials and comply with the following: 1. Water Lines - All water lines shall be Polyvinyl Chloride (PVC) material and be designed, manufactured, and tested in accordance with the applicable requirements of AWVl/A c-900 (eight (8") inch through twelve (12") inch water pipe) AWVl/A c-905 (sixteen (16") inches and larger water pipe), and AWVl/A M-23. 2. Other Pipe Material - All other materials must be submitted for approval by the Director of Public Works Sewi€lEls. Ductile Iron pipe is an acceptable substitution. a. All PVC water pipe shall be blue in color. b. Eight (8") inch through twelve (12") inch water pipe shall be pressure class 150, DR 18. Pressure class 200, DR 14 pipe may be required by the Director of Public Works Sewi€les in areas of high distribution system pressure, under roadways or other unusual circumstances. 3. Fittings - FittiFl~S All fittinQs shall be ductile iron in accordance with AWVl/A C11 0 or AWVl/A C153. a. Fittings: ANSI/AWVl/A c111/A21.11, except gaskets shall be neoprene or other synthetic rubber and factory installed. Natural rubber will not be acceptable. b. All buried metal shall be wrapped in polyethylene Tube Wrap: ANSI/AWVl/A C1 05/A21.5. c. All waterline pipe and fittings shall be new materials and produced in the USA 11.11.>>. Il"IST.\I;.L\TI8~! D. Installation - All installations shall conform to the latest NcTCOG, TCEQ HJRCC, and AWVl/A Specifications, as amended by these standards. 1. All eight (8") inch and ten (10") inch pipe shall be installed with a minimum of forty-eight (48") inches of cover over top of pipe, and pipe twelve (12") inches and larger shall be installed with a minimum of sixty (60") inches of cover over top of pipe. 2. The amount of trench excavation shall not exceed two hundred (200') feet from the end of the pipe Chapter 14 - Engineering Design Standards Page 14 -16 Colleyville, Texas, Land Development Code laying operations, and no more than three hundred (300') feet of total open trench will be allowed. At the end of each work day, all trench excavation shall be backfilled and compacted to the end of the pipe laying operation. Barricades and lights will be required around any open trench or equipment and cover plates are required in traffic areas. 3. All connections to existing water mains shall be made under pressure unless dry connections will not cause any loss of service. Under special conditions connections that cause an interruption of service may be performed with approval of the Director of Public Works Servi@9s. 4. Coated tracer tape or wire shall be installed in the embedment material twelve (12") inches above the PVC pipe with the tracer wire terminating in in-line gate valve boxes accessible by City Staff. 5. Density tests shall be taken at a minimum of every one hundred (100') feet for every lift. A maximum thickness of twelve (12") inches per loose lift is required for all trench backfill. The compaction of backfill shall meet or exceed 95% Standard Proctor density. A geotechnical report should be submitted for all trenches. The density reports shall be submitted daily to the City Inspector. The City has the right to require additional tests if they are deemed necessary. 6. All density reports and bacteria test reports shall be completed, delivered to the Director of Public Works City I!!Fl!!liFleer and Inspector, and approved before paving is allowed to begin. 7. PVC water pipe and appurtenances shall be installed as specified in AWNA M-23 and in accordance with the pipe manufacturer's recommendations. 8. Fittings shall be installed in accordance with AWNA C-600. a. All mechanical joint bends, tees, and reducers which require blocking shall be additionally restrained with EBAA megalug retainer gland or approved equal. b. All fittings must be polyethylene wrapped. 11.11.E FIRE IIYDn!.l'ITS E. Fire Hydrants 1. Hydrant Location and Spacing - Fire hydrants shall be provided alona fire apparatus access roads and adiacent public roads. iFl @sfflffler@ial aFl€l iFl€lIol~trial areas &Rall seFlerally Iae Is@ate€l at street iFlterSeGtieFls aFl€l &I'laee€l &8 a& t8 I'lrsvi€le fire Ry€lraFlt Gsverase \.Jitl;! a ff1a)(iffllolffl ra€lilol& sf tl;!ree I;!IoIR€lre€l (Jgg') feet aR€l a ff1aXiffllolffl I;!S~9 lay sf five I;!IoIR€lre€l (599') feet. Fir;e Ry€lraRt& iR a resi€leRtial area sRall seFlerally Iae Is@ats€l at ~tr99t iFlter~e@tisFlS aR€l Sl'la@e€l &S as ts I'lre\'i€l9 fir;e Ry€lraFlt @evera!!l9 witR a ff1aXiffllolffl ra€lilols sf five RIoIFl€lrs€l (599') feet aFl€l a ff1axiffllolffl Rese lay sf six RIoIFl€lre€l (099') feet. (0-00-1261 12/19/00) a. The minimum number of fire hydrants available to a buildinQ shall not be less than that listed in Appendix B of the 2000 International Fire Code. as amended. b. The number of fire hydrants available to a complex or subdivision shall not be less than that determined by the spacina reQuirements in the followina table. when applied to fire apparatus access roads and perimeter public streets from which fire operations could be conducted. Chapter 14 - Engineering Design Standards Page 14 -17 Colleyville, Texas, Land Development Code 1 750 0 1 2000- 2 2500 3 3000 3 3500- 4 mm..........4.500 - 5.000mmm ......mmmm. mm2 mmmm 5.500 ........ ..mmm ....... ..m~ m ..m...... ..m.... . ... ., .mm 6.000....... ..... ................ .....~....... mm.. 6.500 - 7.000.mmmmmmmmmmmZm m.. ........ .... 7 500 or more 8 or more 500 450 450 400 ...m..!JM ... ... . . . . m..............!J.QQ . . . . . .mm!J.QQ ......................Wl .....................Wl 200 m .....mmm~ .....mll2m m '.mm ..Zl2 .....mmm.. mmmZl2 ........................................m.llimm..........m...mm...m. ............... ..mmmm........mm..Wl ............ ..mm ......mm...............Wl .. m.. m.... . mmm ..mmm12!lm .... .......... ........................... ..mm ..m12!l 120 2. Materials - Fire hydrants shall be manufactured in accordance with AWWA c-502, Dry-Barrel Fire Hydrants. Hydrants shall be manufactured such that all maintenance and adjustments can be performed without excavation and such that hydrants may be faced in any direction in relation to base. 6.3. Installation depth - The standard fire hydrant bury length from ground to bottom of the connecting pipe shall be three (3') feet six (6') inches. The hydrant shall be of a design that will permit extensions without disturbing the bottom section of the hydrant. G4. Gate valve - A gate valve shall be installed with each fire hydrant. ~5. Manufacturers - Approved fire hydrants manufacturers are as follows: a. Mueller Centerion A-423 b. Watrous Pacer - 100 c. Clow 3.6. Locations - Fire hydrants are to be located a minimum of three (3') feet and a maximum of six (6') feet behind the back of curb. l~.U.F ~7L'''l. "ES F. Valves - Valves of approved design shall be installed at the intersections of all water mains so as to provide for proper maintenance and operation of the system and to provide a means of shutting off the supply to portions of the system for repairs. 1. Valve Spacing - Valves shall be spaced such that only one fire hydrant is out of service at any one time. Three (3) valves shall be used on a four-way water line intersection and a minimum of two (2) valves shall be used on a three-way intersection. 2. Valve Types - Resilient seated gate valves shall be used for six (6") inch through twelve (12") inch water lines. Butterfly valves shall be allowed for twelve (12") inches and larger water lines when approved by the Director of Public Works SeP-liees. 3. Valve Materials a. Resilient Seated Gate Valves (1) Resilient seated gate valves six (6") inches through sixteen (16") inches shall meet or exceed the latest revisions of AWWA C509 and shall meet or exceed the requirements of these standards. (2) Resilient seated gate valves for buried service shall be furnished with a square two (2") inch operating nut. The valve box shall be Tyler Pipe 6850 series or approved equal. Chapter 14 - Engineering Design Standards Page 14 -18 Colleyville, Texas, Lmd Development Code The valve box lid shall be painted safety blue. The paint shall be Glidden or approved equal. (3) All valves must open left and close right. b. Butterfly Valves - Butterfly valves shall meet or exceed the latest revision of AWWA Standard C504 for Class 150B butterfly valves and shall meet or exceed the requirements of this specification. All valve components shall conform to Underwriters Laboratories classification in accordance with ANSI/NSF Standard 61. 4. Valve Installation a. Valves shall be furnished with extensions, such that the working nut is a maximum of thirty- six (36") inches below grade. b. Adjustable valve boxes shall be furnished and set on each valve in accordance with these standards. Valves that are deeper than forty-eight (48") inches, AWWA c900 PVC pipe shall be used for stacks, as long as the adjustable valve box is used at the top. c. After the final clean-up and alignment has been complete, the contractor shall cast in place a concrete block, twenty-four (24") inches by twenty-four (24") inches around all valve box tops at the finish grade. See detail W-3. d. Valves located within a right-of-way shall be indicated on the face of the curb, or where curbs do not exist, on a conspicuous location adjacent to the valve location. Markings are to be the stamping of a four (4") inch high letter "v" with a three-eighths (3/8") inch stroke with the point of the "V' pointing towards the valve location. e. Valve markers shall be provided in rural areas. 5. Valve Manufacturers a. Approved manufacturers of six (6") inch through twelve (12") inch resilient seated gate valves are as follows: (1) Mueller, Claw and Waterous b. Approved manufacturers of sixteen (16") inches resilient seated gate valves are as follows: (1) Mueller c. Approved manufacturers of sixteen (16") inch and larger butterfly valves are as follows: (1) Mueller and Clow 11.1J.C AIR REhKHJE :.1"ID Fhl,'Smrl(;j Y+.hYES G. Air Release and Flushina Valves - Adequate air relief, and flushing valves shall be provided for flushing, disinfecting, daily operation requirements, and repairs when required by the Director of Public Works Ssp:is9s. Air release valves shall be required on twelve (12") inches and larger water lines. Water lines shall be designed so that each section of the water line can be flushed at its lowest and highest points. ~1.AII dead end lines shall have a fire hydrant installed for flushing purposes. If installation of a fire hydrant is not possible, a flushing valve is required. a..2.A fire hydrant shall be required at high points on water lines smaller than twelve (12") inches for air relief and flushing. 4.3. Materials - Air release valves and air/vacuum valves shall meet or exceed the latest revision of Chapter 14 - Engineering Design Standards Page 14 -19 Colleyville, Texas, Land Development Code AWWA C512. 11.12.11 T:.PPU'I€J ShEE\'E H. TaDlJina Sleeves - A tapping sleeve and valve shall be used when connecting a new water line to an existing line. A resilient seated gate valve shall be flanged to the tapping sleeve. The tapping sleeve shall be a Smith-Blair Spec. 664-665 stainless steel tapping sleeve, or approved equal. 11.12.1 'lV.HER SER'/ICE I. Water Services 1. Meter Box Locations - The water meter box shall be placed a minimum of two (2') feet behind the back of curb unless sidewalks are adjacent to the curb, then they are to be set seven (7') feet behind the back of curb, and the water service shall be a minimum of twelve (12") inches deep, covered with a meter box in place at grade. If no curb is present, the water service shall be located at the property line, a minimum of twelve (12") inches deep, covered with a meter box in place at grade. Along roadways without a curb the water service line shall be constructed at a minimum of twelve (12") inches below the ditch flow line. All water services crossing beneath streets may be encased in four (4") inches diameter PVC casing. 2. Meter Size - Meter and service sizes will be determined by the developer prior to requesting service from Colleyville. The minimum water service size between the water main and the meter shall be one (1") inch. Water services on undeveloped lots shall be located at the property line and shall be a minimum of one (1") inch in diameter. 3. Materials a. Service Saddle - Service saddle shall be double strap bronze with brass body or nylon I epoxy coated stainless steel double bolt wide straps. Minimum size tap shall be 1 inch diameter. (1) Approved manufacturers for bronze saddles are Ford, Mueller, Jones or Smith-Blair. (2) Approved manufacturers for nylon stainless steel saddles are Ford, Mueller, JcM or Romac. b. Service Line - Service lines shall be one (1") inch minimum diameter, Type K copper as specified in ASTM B88. c. Corporation Stop - Corporation stop shall be ball type with a diameter equal to the pipe size with compression outlet fitting, designed for a minimum working pressure of two hundred pounds per square inch (200 psi) and threaded counter clockwise. Approved manufacturers are Ford or Mueller. d. Angle Stop - Angle stop shall be set with compression inlet fitting and locking wings. Approved manufacturers are Ford, Mueller or Smith Blair. e. Meter Boxes - Meter box for one (1") inch meters are to be East Jordan Iron Works brand and are to be #37-S Plastic Box with Cast Iron Lid. Meter box for one and one-half (1 Yz") inch and two (2") inch meters shall be East Jordan Iron Works brand and are to be a 15x27 plastic box with 2 65T dual lids. 4. Installation a. All water service! shall be installed in accordance with these standards. b. Each individual service location shall be saw cut into the face of the curb with a four (4") inch high 'W" painted blue by the Contractor. If no curb exist a similar mark should be placed in the pavement near the edge of the roadway. 5. Acceptable Manufacturers for Corporation Stops. Curb Stops. and Service Saddles Chapter 14 - Engineering Design Standards Page 14 - 20 Colleyville, Texas, Land Development Code a. Ford b. Mueller c. Smith-Blair 11.1J.J FU:fSIIIN€J 'lz, '1.1:, '.'ES J. FlushinCl Valves 1. Materials a.L..Corporation stop shall be two (2") inch ball type with compression outlet fitting, designed for a minimum working pressure of two hundred pounds per square inch (200"). 9.2. Two (2") inch curb stop shall be ball type with compression inlet fitting with tee head shut off. G.3. Pipe shall be two (2") inches diameter, Type K copper as specified in ASTM B88. 9.4. All flushing valves shall be installed within a twenty-four (24") inch round metal meter box. 11.l2.K W".rER 1.1l'JE R9RE 1. Casir:H~s K. Water Line Borings - Casings shall be required under collectors and thoroughfares, highway crossings, and railroad crossings. Casings may also be required where deemed necessary by the Director of Public Works ServiGes. Minimum casing thickness shall be a quarter (1/4") inch. The construction bore pit shall be located a minimum distance of four (4') feet behind the back of curb or edge of pavement where no curb is present. 2-.1. Casinq Desiqn - The design engineer shall design the water line pipe casing for the following loading conditions and applicable combinations thereof: a. Cooper's E-80 Railway loading or AASHTO HS20 loading as applicable. b. Earth loading with the height of fill above the casing as shown on the plans. c. Loads applied during jacking, including axial load from jacking. d. All other applicable loading conditions, including loads applied during transportation and handling. ...2. Casing Materials a. Steel Casing Pipe - Steel casing pipe shall be new (or used if approved by the Director of Public Works ServiG8s) and suitable for the purpose intended and shall have a minimum yield strength of 35,000 psi. Casing shall meet ASTM A-36, ASTM A-570, ASTM A-135, ASTM A-139, or approved equal. Pipe shall be coated with coal tar epoxy (15 mils min.) in accordance with AWWA C-210. Pipe joints shall be welded in accordance with AWWA C- 206. After pipe is welded, coating shall be repaired. b. Cement Mortar - Cement mortar shall consist of one (1) part cement to two (2) parts clean sand with sufficient water to make a thick, workable mix. c. Pressure Grout Mix - Grout shall be comprised of one (1) cubic foot of cement and three and a half (3.5) cubic feet of clean fine sand with sufficient water added to provide a free flowing thick slurry. If desired to maintain solids in the mixture in suspension, one cubic foot of commercial grade bentonite may be added to each twelve (12) to fifteen (15) cubic feet of the slurry. d. Casing Insulators (Spacers) - Use casing insulators for any type of carrier pipe. Insulators shall be high density polyethylene. Insulators shall fit snug over the carrier pipe and position the carrier pipe approximately in the center of the casing pipe to provide adequate clearance between the carrier pipe bell and the casing pipe. Insulators shall be manufactured by "Recon" and be Racci Type or approved equal. Chapter 14 - Engineering Design Standards Page 14 - 21 Colleyville, Texas, Land Development Code 4.3. CasinCllnstallation a. Excavation and Backfill of Access Pits (1) Do not allow excavation over the limits of the bore or tunnel as specified. Trench walls of access pits adjacent to the bore or tunnel face shall be truly vertical. Shore the trench walls as necessary to protect workmen, the public, structures, roadways, and other improvements. (2) Excavations within the right-of-way and not under surfacing shall be backfilled and consolidated by mechanical methods as specified in these standards for compaction of trenches under roadways. Surplus material shall be removed from the right-of-way and the excavation finished to original grades. Backfill pits immediately after the installation of the carrier pipe is completed. If carrier pipe is not installed immediately after casing pipe installation, the City may require the access pits be temporarily backfilled until installation of carrier pipe. (3) Where seeding or sodding is disturbed by excavation or backfilling operations, such areas shall be restored to the existing or better conditions. Section 14-165 Wastewater System Improvements 1 ~ ,1 J.j'..A.General - This section pertains to general design requirements for wastewater collection system construction in the City of Colleyville. All sewer lines shall be sized and designed in accordance with the City of Colleyville Waste Water System Master Plan or as determined by the Director of Public Works SePJiG8s. In the absence of or in conflict with a specific standard contained in this Chapter, all collection, treatment, and disposal systems shall be designed in accordance with the most current criteria adopted by the Texas Administrative Code, Chapter 317, "Design Criteria for Sewerage Systems", NCTCOG, TCEQ HJRCC and ASTM. H.IJ.B SE',YER LUIE SIZES .HID DESIQrl B. Sewer Line Sizes and Deskm 1. Standard sewer line sizes are six (6") inches, eight (8") inches, twelve (12") inches, fifteen (15") inches, and eighteen (18") inches in diameter. Other sizes may be approved by the Director of Public Works SePJiGe~. 2. Sewer lines shall be constructed at a minimum depth of four (4') feet and be located within the parkway or an approved utility easement. A sewer line is required to be constructed on both sides of a State Highway. 3. Easements for sewer line construction shall meet the following requirements: a. The easement width shall be a minimum of fifteen (15') feet. Greater easement width may be required for deep lines. b. If the sewer line is less than twelve (12') feet deep, the outside diameter of the sewer line shall be located a minimum distance of six (6') feet from the edge of the easement, and if other utilities are located in the same easement, the outside diameter of the sewer line shall be located a minimum distance of three (3') feet from the outside diameter of the other utilities. c. If the sewer line is greater than twelve (12') feet deep, the outside diameter of the sewer line shall be located a minimum distance of nine (9') feet from the edge of the easement, and if other utilities are located in the same easement, the outside diameter of the sewer line shall be located a minimum distance of six (6') feet from the outside diameter of the other utilities. d. Proper separation of utilities must be maintained per TCEQ HJRCC regulations. Chapter 14 - Engineering Design Standards Page 14 - 22 Cofleyville, Texas, Land Development Code 4. All sewers shall be designed with consideration for serving the full drainage area subject to collection by the sewer in question; the drainage area may be modified with the concurrence of the Director of Public Works Sewis8& because of the projected rate of development or the financial feasibility of the proposed extension. 5. Sewers should be designed with straight alignment whenever possible. When horizontal curvatures must be used, radial pipe must be used in accordance with the pipe manufacturer's recommendations. No joint deflection is allowed without the approval of the Director of Public Works SSWiS8&. 6. All sewers shall be designed with hydraulic slopes sufficient to give mean velocities, when flowing full or half full, of no less than two (2') feet per second. 7. When a one hundred fifty pounds per square inch (150 psi) rated sewer line is required due to its proximity to a water line, the one hundred fifty pounds per square inch (150 psi) rated pipe shall terminate at a manhole on each end. The pipe shall be extended to the interior wall of the manhole. No external boot connection will be allowed. 11.U.C SE'\'.'ER LIl'lE M:.TERL'.b~ C. Sewer Line Materials - All sewer lines and fittings shall be new materials and comply with the following: 1. All sanitary sewer pipes shall be Polyvinyl Chloride (PVC) pipe type SDR-35 for sewer lines constructed less than fifteen (15') feet deep. SDR-26 shall be provided where sewer lines exceed fifteen (15') feet. PVC pipe will not be allowed for depths greater than twenty four (24') feet unless approved by Director of Public Works Servisss. 2. All PVC sanitary sewer pipe shall be green in color. Developer to provide a manufacturers statement for pipe color other than green. 3. PVC sewer pipe and fittings shall conform to the current ASTM Designation D 3034 for four (4") inches through fifteen (15") inches and ASTM Designation F 679 for greater than fifteen (15") inches. 11.lJ.ll SE'.'.'ER LII'IE II"I~Fr.\bb:<,'fI91'1 D. Sewer Line Installations 1. General a. All installations shall conform to ASTM Designation D2321, and the latest NCTCOG Specifications as amended by these standards. b. Sewer lines shall not be installed within nine (9') feet horizontally of any water main or fire hydrant. Where this is not possible, separation shall be in accordance with TCEQ nlRCC standards. c. Construction shall begin at the downstream end of project and continue upstream with the bell facing upstream. No upstream piping shall be installed before downstream piping unless approved by the Director of Public Works Serviss€:. 2. Excavation and Backfill a. Filter fabric shall be installed separating the backfill material from the rock embedment no more than twelve (12") inches above the top of the pipe. b. The amount of trench excavation shall not exceed two hundred (200') feet from the end of the pipe laying operations, and no more than three hundred (300') feet of total open trench will be allowed. At the end of each workday, all trench excavation shall be backfilled to the end of the pipe laying operation. Barricades and lights will be required around any open trench left overnight. Chapter 14 - Engineering Design Standards Page 14 - 23 Colfeyville, Texas, Land Development Code c. Density tests shall be taken everyone hundred (100') feet for every lift. A maximum thickness of twelve (12") inches per loose lift is required for all trench backfill. A geotechnical report should be submitted for all trenches. The compaction of backfill shall meet or exceed 95% Standard Proctor density. The density reports shall be submitted daily to the City Inspector. The City has the right to require additional tests if they are deemed necessary. d. A City inspector will be on site at all times when testing is being performed. The City Inspector shall be present during the placement of trench backfill lifts. e. All density reports shall be completed, delivered to the Director of Public Works City's 1iF1!JiR99r and Inspector, and approved before paving is allowed to begin. 3. Inspection and Testing All sanitary sewer lines shall be inspected using standard television inspection methods prior to acceptance by the City. The developer is responsible for television testing. a. The Contractor is responsible for cleaning the sewer pipe. If the inspection shows debris or evidence that the line has not been properly cleaned, the review will cease and the tape will be returned to the Contractor. b. A City representative will be present during the television inspection and all other testing procedures, unless otherwise authorized in writing. c. The televised inspection shall commence only after the line has passed both air and mandrel test. d. The sanitary sewer system must pass all air, mandrel and television tests prior to paving. e. The air and mandrel test must meet the required specifications set forth by the NCTCOG and TCEQ nIRCC. f. All sanitary sewer mains must be flushed clean with water just prior to televised inspection. All debris must be captured and prevented from blocking the system. Water is to be provided at the Contractor's expense. A City representative is to be present during the flushing of the main. g. All television equipment used shall have a minimum of two hundred twenty (220) lines of horizontal resolution. The picture shall be in color. h. All video information on tape must have good picture quality. i. As a title heading on the tape and during the televising, the operator must not! the following: (1) project name and Contractor name. (2) name of the company and the operator performing the video inspection. (3) line size and material, joint type and length. (4) line segment to be televised including beginning and ending station numbers. (5) page of plans used and year plans were stamped. (6) date and time of inspection. (7) A footage counter must be displayed on the tape during the filming. (8) Show the above title block before and after each line segment. Show the title block at one hundred (100') foot intervals while filming the line segment. (9) All defects should be shown on film for a minimum of ten (10) seconds before proceeding with the televising. j. The Contractor shall supply a log sheet used in conjunction with the video tape for written documentation. All written information gathered must be legible and clearly understandable. (1) Note the project name, Contractor name and contract number. (2) Note the name of the company and the operator performing the video inspection. (3) Note pipe size and material, joint type and length between joints. (4) Note the VCR tape footage counter, start to end. (5) Note line segment to be televised, station numbers from and station numbers to length of line segment as indicated on plans. (6) Note page of plans used and year plans were stamped. (7) Note date and time of inspection. (8) Indicate by sketch the line segment to be televised in relation to surrounding road intersections and street addresses. Identify manhole station numbers. Show direction of flow with arrows and direction the camera is going. Indicate direction of north on the sketch. Chapter 14 - Engineering Design Standards Page 14 - 24 Colleyville, Texas, Lmd Development Code (9) Note the water depth at the beginning, every fifty (50') foot station, every change in grade, and at the end of the line segment. (1 O)ldentify the clock location, direction, size and type of laterals entering main. Indicate laterals as saddles, punched, or glued fittings. (11) Indicate final footage televised at end of the log sheet. k. One tape per visual televised inspection project shall be furnished to the Project Inspector. I. Tapes must be VHS format, one (1") inch wide T-120, high quality tape. Tapes are to be recorded on SP (2 hours) play. m. All tapes and run sheets shall be submitted to the City. All tapes and log sheets shall become the property of the City. 4. Criteria for Repair The Contractor shall make repairs if the inspection reveals any deficiency in the sewer line. If repairs are required, another television inspection shall be made after the repairs are complete on a new tape from manhole to manhole at the Contractor's expense. Any water discovered with a depth of more than one-quarter (1/4") inch will require removal and replacement of the portion of the line not within specification. Repairs shall be made to the satisfaction of the Director of Public Works Sep/iees. 11.U.C M:"J'!II8bE~ E. Manholes 1. Manholes shall be located at all intersections of sewer lines and at intermediate spacing along the line. Generally the maximum spacing should not exceed five hundred (500') feet. Manholes should be located at all changes in grade and at the ends of all sewer lines that will be extended. 2. A manhole is required at the junction of sewer lines with different inside pipe diameters. 3. A drop of at least one tenth of a foot (0.1 ') is required through the manhole when a change in flow direction occurs. 4. A drop manhole is required when the flow line in is two (2') feet or more greater than the flow line out. 5. Minimum manhole inside diameter is four (4') feet. 6. Drop-connection manholes shall have a minimum inside diameter of four (4') feet, with an exterior drop. 7. Minimum cast-in-place manholes must be installed to the North Central Texas COG standards. 8. Minimum pre-cast wall thickness is five (5") inches. 9. A manhole is required where a sanitary sewer line enters and exits private property. 10. All manholes shall be concrete. 11. IFlstallati@F1 a. Sanitary sewer manhole sizes shall be in accordance with the following table: Chapter 14 - Engineering Design Standards Page 14 - 25 Colleyville, Texas, Land Development Code Under 12" ...................~.................... Under 12" ........................................................... 12" to 18" <12' ................................................ > 12' - 20' <12' >12' - 20' 4' .................................................................... 5' 5' 6' 3 ........................................................................................... 3 3 4 Note: If the proposed design requires the sewer line to be placed at depths greater than shown above, the design will require approval by the Director of Public Works esp-iess. 9=. 12. Cast-in-place Manholes t4t!!:. The manhole foundation shall be poured on undisturbed soil and shall have a minimum thickness of eight (8") inches. ~~ The inlet and outlet pipes shall be poured into the foundation of the manhole. When straight through flow occurs, the pipe shall be laid continuously through the manhole. f3t....f:. The invert shall be shaped and smoothed so that no projections will exist and the invert shall be self cleaning. f4t d. When a cast-in-place manhole is used to connect to an existing sewer line the manhole should be poured, tested and approved before the top of the existing line is cut out. fit !:. Concrete work shall conform to all requirements of ACI 301, Standard Specification for Structural Concrete, published by the American Concrete Institute, except as modified herein. ~...t. Detailing of concrete reinforcement and accessories shall be in accordance with ACI Publication 315. fA 9.:. Portland cement shall be Type II, low-alkali and conform to ASTM Designation C-150. ~) h. The manhole shall not be backfilled within twelve (12) hours after the concrete placement. Backfill shall be compacted and reports submitted to the City. f'#) !.:. The face of curb shall be stamped with a three (3") inch "MH" to mark the location of all manholes. The location of the stamp shall be a line that intersects the center of the manhole cover and the curb perpendicular to the centerline of the street. For manholes located in intersections, the curb shall be stamped at the closest location to the manhole. If no curb exist a similar mark should be placed in the pavement near the edge of the roadway. 6.13. Precast Manhole! t4t!!:. Precast manholes shall be constructed in accordance to ASTM Designation C-478. ~b. Manhole base shall have a spread footing and be placed on a minimum of twelve (12) inches of crushed rock. ~.14. Manufacturers - Approved precast manhole manufacturers are as follows: a. Hydro-conduit b. Gifford Hill American l~.U.Q M.\nIISl,E FR.\I'lIE .\1'18 CSYER F. Manhole Frames and Covers 1. Cover a. Materials - All manhole covers shall conform to the Standard Specifications for Domestic Grey Iron Castings, ASTM A-48, Class 30 B. b. Installation (1) All manhole covers shall be twenty four (24") inches in diameter. Chapter 14 - Engineering Design Standards Page 14 - 26 Col/eyville, Texas, Land Development Code (2) All manhole covers shall have two (2) integrally cast pick bars. c. Manufacturers (Traffic rated where necessary) (1) Bass and Hays (2) Vulcan 2. Frames a. Materials - All manhole frames shall conform to the Standard Specifications for Grey Iron Castings, ASTM A-48, Class 30 B. b. Installation - All manhole frames shall provide a twenty four (24") inch by one quarter (1/4") inch opening to assure proper fit of the manhole cover. c. Manufacturers (1) Bass and Hays (2) Vulcan d. Manholes located within the floodplain are to be sealed cover and frame. 3. Extension Ring~ a. Materials - All precast reinforced concrete extension rings shall conform to ASTM C-478. b. Installation 1) The number of extension ring sections shall be kept to a minimum (i.e. use 1-12 inch extension ring instead of 2-6 inch extension rings). 2) A one (1 ") inch by three and a half (3 1/2") inch bitumastic gasket shall be used to seal the extension ring at both joints. 4. Rain Pan a. Materials - Rain pans shall be high density polyethylene plastic. b. Manufacturers - Knutson or approved equal. H.U.E SE\VER SER-"ICE G. Sewer Services 1. No sewer service line (lateral) shall be less than four (4") inches in nominal diameter. 2. Sewer laterals shall be located at the center of the lot and extended to the property line and be a minimum of ten (10') feet downstream of the water service. Services will be identified in the field by a three (3") inch "S" cut into the curb, on the As-Built Plans and with a stake in the field for location purposes. 3. Sewer service laterals shall have a minimum of four (4') feet of cover at the property line. 4. A cleanout shall be located on the service lateral at the time of connection to the home. 5. Materials a. All lateral sewer service lines shall be gasketed PVC pipe type SDR-35. b. All PVC sanitary sewer pipe used for lateral services shall be green in color. (ASTM SPEC) Chapter 14 - Engineering Design Standards Page 14 - 27 CoJleyville, Texas, Land Development Code 6. Installation - All service laterals shall be installed in accordance with the sanitary sewer embedment and backfill standards of the City of Colleyville. 7. Video Insoection Reauired - All sewer service lines that are connected to a section of sewer service oioinQ located within the riQht-of-wav must have a clean-out installed where the orooertv line abuts the riQht-of-wav. After the new sewer service line has been connected and the excavated area is backfilled. the oortion of the sewer service line located within the riQht- of-way includina the tao into the sewer main must be televised. The video taoe must be submitted to and aooroved bv the City of Collevville Public Works Deoartment. 8. Point of Connection - The ooint of connection for all sanitary sewer service lines shall be made to an aooroved oublic sewer main line. No sanitary sewer service line shall directlv connect to a manhole. M:.m l.INE Cl:.K'.tI8tlT8 11.U.F H. Main Line Cleanouts - Cleanouts may be installed on lines that are permanent dead ends. The line may not exceed two hundred fifty (250') feet. Any line exceeding that length must end with a manhole. SE\','ER l.Il'lE B8RINb 11.U.C I. Sewer Line Borinas 1. The design engineer shall design the sewer line pipe casing for the following loading conditions and applicable combinations thereof: a. Cooper's E-80 Railway loading or AASHTO HS20 loading as applicable. b. Earth loading with the height of fill above the casing as shown on the plans. c. Loads applied during jacking, including axial load from jacking. d. All other applicable loading conditions, including loads applied during transportation and handling. 2. Materials - fMaterials must meet jurisdictional requirements in all areas, Railroad, TCEQ nJRCC, TXDOT, etc...t a. Steel Casing Pipe - Steel casing pipe shall be new (or used if approved by the Director of Public Works 5e~\'iGe&) and suitable for the purpose intended and shall have a minimum yield strength of 35,000 psi. Casing shall meet ASTM A-36, ASTM A-570, ASTM A-135, ASTM A-139, or approved equal. Pipe shall be coated with coal tar epoxy (15 mils min.) in accordance with AWWA C-210. Pipe joints shall be welded in accordance with AWWA C-206. After pipe is welded, coating shall be repaired. b. Cement Mortar - Cement mortar shall consist of one (1) part cement to two (2) parts clean sand with sufficient water to make a thick, workable mix. c. Pressure Grout Mix - Grout shall be comprised of one (1) cubic foot of cement and three and a half (3.5) cubic feet of clean fine sand with sufficient water added to provide a free flowing thick slurry. If desired to maintain solids in the mixture in suspension, one cubic foot of commercial grade bentonite may be added to each twelve to fifteen cubic feet of the slurry. d. Casing Insulators (Spacers) - Use casing insulators for any type of carrier pipe. Insulators shall be high density polyethylene. Insulators shall fit snug over the carrier pipe and position the carrier pipe approximately in the center of the casing pipe to provide adequate clearance between the carrier pipe bell and the casing pipe. Insulators shall be manufactured by "Recon" and be Racci Type or approved equal. 3. Installation Chapter 14 - Engineering Design Standards Page 14 - 28 Col/eyville, Texas, Land Development Code a. Tolerances (1) All bores shall be installed at a grade no less that the minimum indicated by TAC, Chapter 317 for the desired pipe size. (2) All bores shall maintain grade enough to ensure desired clearance distances between existing utilities and bore. b. Excavation and Backfill of Access Pits (1) Bore pits must be a minimum of four (4') feet from the back of curb when located for boring under roadways. (2) Do not allow excavation over the limits of the bore or tunnel as specified. Trench walls of access pits adjacent to the bore or tunnel face shall be truly vertical. Shore the trench walls as necessary to protect workmen, the public, structures, roadways, and other improvements. (3) Excavations within the right-of-way and not under surfacing shall be backfilled and consolidated by mechanical methods as specified in these standards for compaction of trenches under roadways. Surplus material shall be removed from the right-of-way and the excavation finished to original grades. Backfill pits immediately after the installation of the carrier pipe is completed. If carrier pipe is not installed immediately after casing pipe installation, the right-of-way Owner may require the access pits be temporarily backfilled until installation of carrier pipe. Plug ends of sleeves to prevent soil migration. (4) Where seeding or sodding is disturbed by excavation or backfilling operations, such areas shall be replaced to meet existing or better conditions. Section 14-170 Drainage and Storm Sewer Improvements 11.11.1. CEI"JER\h A. General - This section pertains to general design requirements for drainage and storm sewer construction in the City of Colleyville. All drainage facilities shall be sized and designed in accordance with the City of Colleyville Drainage Master Plan or as determined by the Director of Public Works SePlliees. 11.11.B R19nQFf C!.hB19h!. TIml~ 4.!1..Runoff Calculations - The selection of which method to use for calculating runoff depends upon the size of the contributing drainage area at the most downstream point of the project. The "Rational Method" is acceptable for designing projects in which the drainage area is less than one-hundred (100) acres. A unit hydrograph method is required for projects with larger drainage areas. 1. No matter which method is used to calculate runoff, a developer or builder of residential property greater than one (1) acre in size, or any property that was platted as a part of an overall tract which was greater than one (1) acre in size (including churches and schools), shall develop the property so that the rate of runoff created by the development as it leaves the property does not exceed the rate of runoff that is currently occurring in the existing conditions. A developer or builder of commercial property greater than one-half (1/2) acre must follow the above guidelines. ~.2. Runoff computations shall be based upon fully developed watershed conditions in accordance with the land use projections in the latest comprehensive land use plan for the City of Colleyville. The design engineer shall size drainage facilities by disregarding the detention effects of upstream property and calculating the runoff as if the off-site property was developed without any detention. If an approved regional detention/retention facility is in operation, the design engineer may size downstream drainage facilities based on consideration of the detention effects of the regional facility. 4.C.Pn~eea~re fer araiRa~e Drainaqe areas less than one-hundred (100) acres Chapter 14 - Engineering Design Standards Page 14 - 29 Colleyville, Texas, Land Development Code aL Computation of Storm water Runoff for drainage areas less than one-hundred (100) acres shall be by the "Rational Method," which is based on the principle that the maximum rate of runoff from a given drainage area for an assumed rainfall intensity occurs when all parts of the area are contributing to the flow at the point of discharge. J::'.llrl<llT~ll~~.!'!()cJ.~y.f:!I()p~cJ.llll1cJ.m Developed Park sites ...:$.i~9i.~:!::~iT.iily~~~:i~~ht.illlmm . .qLlP'I~'.:'m.. .mlll!L1lt.ip'I~I".ll~iIYm .. Schools . ..............~...._....~............................ Churches .................................................................................................................................... ..t.'!~!9.h.!?<?Th..<?9.cJ..gg.~'!l~r(;illl. .. Office Commercial Co'mmerciiif m ... ............................................. .. Industrial . 0 0.70 O:iO 0.85 0.85 Tl::1e ferFJllolla fer QalebllatieR sf rYReff BY tl::1e "Ratisr;lal Metl::1ea" i~: Q - CII'. \NR9re: Q - tl::1e FJlaHiFJlIolFJl rate ef ai~eRar!je, eXfilressea iR QYBie feet filer seesRa. C - CeElffiQiElRt sf RYRSff. Parl~ areas ~Is aevelsfilsa laml Oevslsfilea Parl< sites SiR!jIEl FaFJlily RElsiaeRtial OYJilIElx Mblltifille FaFJlily Sel::1eels Cl::1l;1rGiI::1Els ~Jei!jI::1Berl::1eea CeFJlFJlElreial Offie8 CeFJlFJlereial CeFJlFJler€ial IRaystrial Q.AQ Q.<10 0.59 Q.GQ 9.60 9.79 0.70 0.:0 0.70 0.70 O.Sii 9.Sii - IRteRsity ef RIoIRSff iR iRGl::1es filer I::1syr (RefereRGe Ql::1art frsFJl tRe Ft. 'JI.'ertl=l OraiRa!js MaRyal). A - OraiRa!jEl.'\rEla iR aQre~. 9.2. Time of concentration is the longest time, without interruption of flow by detention devices that a drop of water takes to flow from the farthest point of the drainage area to the point of concentration (i.e. the point of design). The time of concentration is composed of the inlet time and the flow time in a conduit or channel to the point of design. The inlet time shall be 10 minutes for property zoned multiple family, churches, schools, local business, central business, commercial, or industrial. An inlet time of 15 minutes shall be used for property zoned for parks, cemeteries, agricultural, and single family residential. When designing inlets and laterals, the time of concentration is equal to the inlet time. The design engineer will compare the above specified inlet times to the actual calculated inlet time by computing Chapter 14 - Engineering Design Standards Page 14 - 30 ColleyvilIe, TexJs, Land Development Code the flow time overland and along the gutter to the first inlet. Manning's Equation shall be used to determine flow time to the inlet. The design engineer may use the actual calculated or specified inlet time. In no case shall a longer inlet time be used than 10 minutes for multiple family, commercial, churches, schools, industrial and business areas and 15 minutes for parks, cemeteries, agricultural, and single-family areas. @.D.PFe@e€hm~s Wf; Drainaqe Areas €lrsGlter tFlGlf! of one-hundred (100) acres or more ae.1.For drainage areas if! en(@e~~ of one-hundred (100) acres or more where the use of the "Rational Method" does not provide reliable results, the use of a unit hydrograph method shall be made. The use of a unit hydrograph calculation will be based upon standard and accepted engineering principles subject to the approval of the Director of Public Works SSPli@Qs. Acceptable methods include the Soil Conservation Service (SCS) Technical Release Number 55 or the Corps of Engineers HEC-1 models for drainage areas one-hundred (100) acres or more. &.2. The unit hydrograph method shall be based upon fully developed watershed conditions assuming no effects from the small on-site detention facilities for maintaining the rate of runoff as if the property was undeveloped. The detention effects of large regional detention facilities can be taken into account in unit hydrograph methods. 9.3. Circumstances that may require the use of a unit hydrograph method include sizing open channels, reclaiming floodplains, creating lakes, or building other types of drainage-related facilities on major drainage courses. Design engineers of these types of facilities should be aware that the requirement of designing for fully developed watershed conditions will mean that they will have to calculate these fully developed flows instead of using the flows calculated in the Federal Emergency Management Agency's (FEMA) flood insurance studies for Colleyville or Tarrant County or from studies performed for or approved by the City of Colleyville. H.H.C 9EsmN ~T8RI\I FRE€H:TEr'JCIES E. Deskin Storm Freauencies - All developments submitted must provide data for the following design storm frequencies: 2-Year 15-Year 110-Year I 25-Year I 50-Year 1100-Year. 1. Drainaae facilities shall be desif:Ined in accordance with the followina table: Closed Storm Sewer Systems : 5-year with 1 DO-year positive overflow in streets , such that the depth of flow in the street does not , exceed the right-of-way or drainage easement m...mmmm....mmm...Lc;l:iPClC;i!y:mm...m Closed Storm Sewer Systems 1 DO-year with positive overflow and Inlets at Street Low Point ...~.r....~.~.9...................................... .....g.1:l..ly~~~...l:J.r:'~..~.r.i.~.g.~.~..................... Concrete-lined Channels .......................R................................................................. Earthen Channels 100- ear ...!99~y~?.r. 1 00- ear 2. The approved drainage system shall provide for positive overflow at all low points and these areas must be denoted on the plans as such. The term "positive overflow" means that when the inlets do not function properly or when the design capacity of the conduit is exceeded, the excess flow can be conveyed overland along a grassed or paved course. Normally, this would mean along a street or alley, or shall require the dedications of special drainage easements on private property. 11.11.9 STREET .\rID fabl.E'.' C.W.'.CITY F. Street and Allev Capacity Chapter 14 - Engineering Design Standards Page 14 - 31 Colleyville, Texas, Land Development Code 1. Streets - Streets and storm drains within new developments shall be designed so that storm water runoff resulting from a design storm of a one-hundred (100) year frequency is contained within the available right-of-way and/or drainage easement. The capacity of the street and right-of-way and/or easement and the storm sewer pipe working in combination must be designed for a capacity to safely contain a storm water from a design storm of one-hundred (100) year frequency. 2. Alleys - The flows created by the one-hundred (100) year storm shall be contained within the capacity of all paved alleys. 11.11.E Il'll,ET Pl,.'.CEUENT .\ND C\PJ..CIT'..' 4..G. Inlet Placement and Capacity - The storm sewer system is to begin at the point where the storm water from a five (5) year frequency storm reaches curb depth, with the exception of collector streets on which storm sewer facilities must be designed to prevent one-twelve (12') foot wide lane from ponding and on major streets on which storm sewer facilities must be designed to prevent one-twelve (12') foot wide lane in each direction from ponding. At such point where the combined capacity of the street and storm drain system satisfies the five (5) year street capacity criteria (as previously described) but the one- hundred (100) year frequency storm runoff can not be contained within the right-of-way additional pick-up points (inlet capacity) shall be provided along with an increase in storm sewer capacity so that the one- hundred (100) year frequency storm runoff will be contained within the right-of-way. ~..1.lnlets shall be placed upstream from an intersection whenever possible. At any intersection, only one street shall be crossed with surface drainage and this street shall be the lower classified street. When an alley intersects a street, inlets shall be placed in the alley whenever flow down that alley would cause the capacity of the intersecting street to be exceeded. 3.2. The minimum inlet size shall be ten (10') feet. No more than twenty (20') feet of inlet shall be placed along one gutter at any given location. Minimum sizes of laterals shall be twenty-one (21") inches for use with ten (10') foot inlets, and twenty-four (24") inch laterals with fourteen (14') foot, twenty (20') foot inlets, and drop inlets. Where laterals tie into trunk lines, place the laterals on a minimum angle forty-five (450) degrees and a maximum angle of sixty (600) degrees with the trunk line and connect them so that the longitudinal centers intersect. 4.~Manholes are required every three hundred feet (300'). Junction boxes are required at every change in flow line direction, change in pipe size, and where a convergence of more than two pipes occurs. Manholes are to be five feet (5') square and can be precast or cast in place. 11.11.F PIPE J)ESI€irl ~T.'.1'18".R8S H. Pipe Deskin Standards 1. Storm sewer conduit shall be sized to flow full. Manning's Equation shall be used to determine the conduit size. 2. MiRiR:l~FR aRa Ma)(iFR~R:I Desian Velocities iR Pi~E1s a. +Re minimum '/eleGities iR GeRa~it sRall ee - two and a half feet (2.5') per second. b. Maximum velsGity iFl tR8 ~i~El st;!all FIst 8HG8El€l- twelve feet (12') per second. c. The maximum discharge velocities in the pipe shall also not exceed the permitted velocity of the receiving channel or conduit at the outfall to prevent erosive conditions. The maximum outfall velocity of a conduit in partial flow shall be computed for partial depth and shall not exceed the maximum permissible velocity of the receiving channel unless controlled by an appropriate energy dissipater (e.g. stilling basins, impact basins, riprap protection). 3. In general, storm water shall be carried in concrete pipe conduit within the right-of-way but other types of conduit can be used to carry stormwater in areas other than the right-of-way. However, prior permission to use other conduit materials must be obtained from the Director of Public Works Chapter 14 - Engineering Design Standards Page 14 - 32 Colleyville, Texas, Land Development Code SePliGe~. 4. Hydraulic Gradient (also refer to the Ft. Worth Drainage Manual) a. Conduits must be sized, and slopes must be set, such that runoff flows smoothly down the drainage system. To insure this smooth passage, the hydraulic gradient must be at the proper elevations. The hydraulic grade line shall be established and shown on the plans for all storm sewer design. b. The hydraulic grade line shall in no case be closer to the surface of the ground or street than one foot (1 '). The HGL must not exceed the neck into the inlet. c. Hydraulic gradient calculations shall account for all head losses that may occur in the storm sewer line. Friction head loss shall be determined by direct application of Manning's Equation. Minor losses due to turbulence at structures shall be determined using Appendix A of this section. 5. Inspection / Testing !!:. The compaction of backfill shall meet or exceed 95% Standard Proctor density. a,. b. All storm sewer conduits shall be inspected prior to acceptance by the City. All conduit forty-two inch (42") or less shall be inspected using television inspection. Conduits larger than forty-two inch (42") may be inspected visually. Do ~ A City representative shall be present during the television inspection. G. d. Televised Inspection Criteria (1) All television equipment used shall have a minimum of two-hundred-twenty (220) lines of horizontal resolution. The picture shall be in color. (2) All video information on tape must have good picture quality. (3) As a title heading on the tape and during the televising, the operator must: k!.:. Note the project name and Contractor name. "'" ii. Note the name of the company and the operator performing the video inspection. Uk iii. Note line size and material, joint type and length. M iv. Line segment to be televised including beginning and ending station numbers. ).k v. Note page of plans used and year plans were stamped. VJ.. vi. Note date and time of inspection. vu.. vii. A footage counter must be displayed on the tape during the filming. vu. viii. Show the above title block before and after each line segment. Show the title block at one-hundred (100') foot intervals while filming the line segment. IX. ix. All defects should be shown on film for a minimum of ten (10) seconds before proceeding with the televising. (4) The Contractor shall supply a log sheet used in conjunction with the video tape for written documentation. All written information gathered must be legible and clearly understandable. k !.:. "'" ii. inspection. tU,. iii. Note pipe size and material, joint type and length between joints. AI,. iv. Note the VCR tape footage counter, start to end. ~ y:. Note line segment to be televised, station numbers from and station numbers to length of line segment as indicated on plans. ~ vi. Note page of plans used and year plans were stamped. ~ vii. Note date and time of inspection. VUkviii. Indicate by sketch the line segment to be televised in relation to surrounding road intersections and street addresses. Identify manhole station numbers. Show Note the project name, Contractor name and contract number. Note the name of the company and the operator performing the video Chapter 14 - Engineering Design Standards Page 14 - 33 Colleyville, Texas, Land Development Code direction of flow with arrows and direction the camera is going. Indicate direction of north on the sketch. ~ ix. Note the water depth at the beginning, every fifty (50') foot station, every change in grade, and at the end of the line segment. X. & Identify the clock location, direction, size and type of laterals entering main. Indicate laterals as saddles, punched, or glued fittings. XJ.. xi. Indicate final footage televised at end of the log sheet. 9.5. One tape per visual televised inspection project shall be furnished to the Project Inspector. .7.~Tapes must be VHS format, one (1") inch wide T-120, high quality tape. Tapes are to be recorded on SP (2 hours) play. i.7. All tapes and run sheets shall be submitted to the City. All tapes and log sheets shall become the property of the City. 11.11.C Cl:Tl:. ':ERT DE~u;J~1 I. Culvert Desian 1. One (1 ') foot of freeboard is required between the one-hundred (100) year water surface elevation and the top of curb elevation. Exceptions must be approved in writing by the Director of Public SBPli€ieG Works. 2. Culverts must be designed using standard engineering practices and engineering judgement. Culverts shall be designed in accordance with the latest edition of the City of Fort Worth Drainage Manual. If the City of Fort Worth Drainage Manual does not incorporate the necessary standards please refer to the Texas Department of Transportation (TxDOT) Hydraulic Design Manual. 3. Culvert hydraulic grade line calculations shall consider both inlet and outlet control. 4. Culverts shall be eke'uB€! eWGR tRat iml'laGt~ €!WQ te tRe flee€! aR€! Rermal fie'!: aR~lee sf attaGI( SF! tRe GtrwEltwre are miRimize€! aliQned to provide the minimum resistance to the flow of water durina the 10. 50. 100 and 500 year events. 5. The maximum velocity through a culvert shall be fifteen (15') feet per second. 6. Stream stability shall be assessed when determining the number of barrels, height and width and culvert skew. Potential for scour shall be accounted for in the design. 7. Hydraulic jumps shall not be allowed from face of culvert to fifty (50') ten (10') feet from the culvert, subiect to the approval of the Director of Public Works. 11.11.11 BRIBfJES !. J. BridQes - Two (2') feet of freeboard is required between the one-hundred (100) year water surface elevation and the low chord of the bridge. Exceptions to this requirement must be approved by the Director of Public Works SepjiGe~ in writing. ~.1.:. The skew of the bridge piers and abutments shall be oriented as close to the normal or flood direction of flow resulting in an angle of attack as close to zero (0) degrees as possible. 2. BridQe piers shall be aliQned to provide the minimum resistance to the flow of water durina the 10. 50, 100 and 500 year events. 3. Computer modeling programs used for the hydraulic analysis of bridges shall be HEC-RAS, Version 2.2. or HEC2. Chapter 14 - Engineering Design Standards Page 14 - 34 Colleyville, Texas, Land Development Code 4. Stream stability shall be assessed when designing the abutments and interior bents of the bridge. Scour shall be accounted for in the design. 5. Fie',,' sl:lall Ret B9 Where flows are supercritical, erosion control measures shall be used in an area from one-hundred (100') feet upstream from a bridge to twenty-five (25') feet downstream from a bridge. CILHIr'IEJ,$ 11.11.1 t. K. Channels - Open channels may be used instead of an enclosed system when a pipe greater than an eighty-four (84") inch diameter (or other shape equivalent to more than thirty-eight and a half (38.5) square feet) is required to carry the design storm event. ~..1..o~8R Cl:laRRel Design Criteria: a. All open channel design must follow the Corp of Engineers Guidelines. b. Channels may be left in their natural state provided that the channel velocities are six (6.0') feet per second or less and that one (1') foot of freeboard is available during the design storm event. c. If the natural channel is to be replaced by an improved channel, the flow from the one-hundred (100') year design flood must be contained within the improved channel while allowing for one (1') foot of freeboard. d. Improved channels shall be trapezoidal shaped and include a lined section if the design velocity is greater than six feet per second. Lining types such as concrete, rock walls and gabions may be used upon approval of the Director of Public Works ~9rviQ9~. The maximum velocity allowed in concrete lined channels is fifteen (15') feet per second. e. Unless shown to be feasible in a soils report sealed by a licensed professional engineer in the State of Texas, and approved by the Director of Public Works ~erVi€l9S, improved channels shall have minimum side slopes of: ill 4 feet horizontal to 1 foot vertical for earthen, grassed-lined side slopes. m 2 feet horizontal to 1 foot vertical for concrete-lined side slopes iR ~9€l1~. f. Where practicable, all unpaved channels should have sufficient grade to avoid ponding. A minimum slope of ~ 1.00% is required for earthen channels and swales, except those used as part of a wetlands area. In areas where ~ 1.00% cannot be obtained a pilot channel approved by the City may be used. All lined channels are to have a minimum slope of 0.50% and ~ earthen channels a minimum slope of 1.00%. g. The developer or owner shall use low maintenance vegetation for vegetative cover, as approved by the Director of Public Works ~9rviQe~ prior to planting. The selection of materials shall comply with eitAef; the current ground cover listing for North Central Texas furnished through the Texas Agricultural Extension Service. a..2. Manning's Equation can be used to design channels and determine water surface elevations and velocities when backwater effects are negligible, subiect to approval bv the Director of Public Works. Channels where backwater effects occur must be designed using models accepted by FEMA. 4.3. All channel sections must consider and account for channel stabilization in their design. This requirement pertains to all sections whether they are left in their natural condition or are modified in any manner. The design of all drainage channels and swales shall assure adequate capacity and minimum maintenance to overcome the result of erosion, silting, sloughing of bends or similar occurrences. fF.4. When performing hydraulic analyses for channel or drainageway design, the one-hundred year (100) Chapter 14 - Engineering Design Standards Page 14 - 35 Colleyville, Texas, Land Development Code year starting water surface shall be based on the following: a. Known water surface elevations should be used where possible. Known elevations are available for some creeks and channels from previous studies approved by the City. b. When known water surface elevations are not available the slope-area method or a rating curve may be used. (1) A rating curve approximates the starting water surface elevation for a given flow by using the relationship between known flows and water surface elevations for the creek. This is an excellent method for determining starting conditions if good data is available to develop the rating curve. (2) The slope-area method approximates the starting water surface elevation by calculating the normal depth for the channel. To calculate normal depth the slope of energy gradient for the channel is required. The energy slope can be approximated using the average slope of the channel or the average slope of the water surface. 9.5. The design of the channel lining shall take into account the super-elevation of the water surface around curves and other changes in direction. In general a radius that is three (3) times the top width of the water surface during the design storm event is recommended for channel bends. +'6. A chain link fence six (6') feet in height, or other improvements as approved on a case by case basis by the Director of Public Works SerVi€BS, shall be constructed on each side of the lined channel. 3.7. Gabion or other forms of channel lining a~El ~ref9rrBel may be used in lieu of reinforced concrete lining with the approval of the Director of Public ~er.ti€ie& Works. 11.11.J DEl'EI'ITI€1rl :DE~mr>1 L. Detention DesiQn - Runoff rates for all land uses shall be limited to the rates that would be produced from single family residential areas. This requirement also applies to the development of sites as churches, schools, and other institutional uses. Detention/retention facilities shall be designed for the fully developed one-hundred (100) year design flood according to the following criteria: 1. The minimum amount of storage volume of the detention basin shall be that volume required to reduce runoff rate durinQ the 100 year event to the undeveloped rate. The outflow structure shall be sized to reduce the 2. 5. 10. 25. 50. and 100 year discharQes to the undeveloped rate. Dedicated detention/retention basins shall also include an additional one foot of freeboard and two feet of sediment storage. The volume of runoff storage for drainage areas greater than one-hundred (100) acres shall be computed using unit hydrograph procedures. Acceptable unit hydrograph procedures are provided in Section 14-170.D.114.S.~.5 of this document. For drainage areas less than one-hundred (100) acres, the above methods are recommended; however, an approximate routing method based on the modified rational method fGrmlolla is allowable. 2. All detention facilities designed shall consider the timing of the flood peak in the main channel into which the detention facility drains. Delaying the peak from a site in lower portions of a watershed may result in a higher peak on the main channel. The Director of Public Works may reauire that upstream and downstream ponds be included in the detention desiQn model. 3. A detention facility shall have enough gradient to ensure positive drainage to the outlet structures so as to avoid nuisance conditions such as standing water, odors, insects, and weeds. A minimum slope of 0.50% towards the outlet structure is required for all grass lined detention facilities. 4. Detention areas in parking lots shall not be: a. In required parking spaces. b. Behind speed bumps unless the speed bumps are made with reinforced concrete. Chapter 14 - Engineering Design Standards Page 14 - 36 Colleyville, Texas, Land Development Code c. Deeper than six (6") inches unless otherwise approved by the Director of Public Works Servises. 5. Drainage easements shall be provided for all regional detention/retention facilities and for other detention/retention facilities where two or more owners are involved. 6. Individual Qgetention facilities shall be designed to empty in less than three (3) tv/aRty fe~r ~24) hours, unless it is also serving as an erosion control facility. 7. Detention facilities used as a sediment control facility ~ shall meet the following requirements; a. The sediment control facility shall be designed with minimal velocities such that sediment is dropped and not picked up by flows at any time during the storm event. b. The basin shall be designed with i3€le~~G1te two (2) feet of sediment storage area so that sediment removal is not required more than twice a year. Expected removal periods greater than twice a year must be specified in the maintenance plan and approved by the Director of Public Works S8r;\'ise~. c. Sediment control facilities cannot be used to meet detention requirements unless the volume of sediment is included in the calculations for the detention basin design. 8. The owner shall maintain detention/retention facilities unless the facilities are dedicated to the City of Colleyville. Detention facilities must be properly maintained if they are to function as intended over a long period of time. The following measures are required to ensure the facility functions properly. a. Facilities should be mowed at least twice a year to control weeds and discourage woody growth. b. Debris, litter and accumulated sediment should be removed from detention facilities at least twice a year. Particular attention should be given to removal of debris, litter and sediment around outlet structures. The Director of Public Works may reauire that the property owner remove said debris when in the Director's determination that property damage or a flood hazard may exist. c. Detention basins designed for sediment removal shall be maintained as specified in the maintenance plan and approved by the City with construction plan submittal. 1 ~.1 i.K Fh\:Jl'\fES 4.. M. Flumes - The use of flumes is not recommended for widespread use. Flumes shall not be permitted when the purpose of a permanent flume is to carry runoff down the sides of earthen channels. ;;!.1:,A flume may be used to direct overflow runoff along property lines until the runoff can be intercepted by streets or conduits. A flume shall not carry more than ten (10) cubic feet per second during the one-hundred (100) year storm event with a slope of 1.00%. a.2. All flumes crossing sidewalks shall be covered or bridged such as to minimize danger to pedestrians. 4.3. All edges are to be protected with rock rip-rap or other form of protection for erosion control and scour purposes. 1 i.l ~.l. l..\H.ES N. Lakes - Approval to develop in any area subject to inundation by a lake must be obtained from the appropriate agency responsible for that particular lake before the city grants its approval. Agencies that should be contacted include U.S. Army Corps of Engineers, Tarrant County Water Control Board, TCEQ nIRCC, the Trinity River Authority, and FEMA. Regardless of approvals obtained from those agencies listed above, no filling, development or construction in any area subject to inundation by a lake shall occur without the approval of the City Chapter 14 - Engineering Design Standards Page 14 - 37 Colleyville, Texas, Land Development Code Manager. The City Manager may require any studies necessary to determine that filling, development or construction will not have a detrimental effect on adjacent, upstream or downstream properties and buildings. This subsection in no way diminishes other requirements of this section. 1 ~.1 O\f l.QT Iln':.I]\J.\€lE ,HID CI1.\DII'I€l 4.. O. Lot DrainaQe and Grading - Grading and drainage of all residential lots shall be designed in a manner which will allow one lot to drain across an adjacent lot and into a permanent structure, such as a concrete flume, lined channel, or proper inlet to an adequate drainage facility, or to a street right-of-way. If an approved drainage structure is not present, it will be required of the developer to construct the necessary facilities. (0-00-1261/12/19/00) ;;!.1:, Sheet flow techniques shall be used for lot to lot drainage where possible. (0-00-1261/12/19/00) a.2. Single lots shall accommodate their own drainage into an approved structure where topographic elevations allow this to occur. (0-00-1261/12/19/00) Section 14-175 Miscellaneous 1 i.U.I_ TREl"ICII K\fETY A. Trench Safety - In conformance with House Bills 662 and 665 as passed by the Seventieth Legislature Regular Session of the State of Texas, all construction projects within the City of Colleyville or its extraterritorial jurisdiction as provided by the Municipal Annexation Act (Article 970a, Vernon's Texas Civil Statutes) shall contain provisions for trench safety. On construction projects in which trench excavation will exceed a depth of five (5) feet, the uniform set of general conditions must require that the bid documents and the contract include detailed plans and specifications for adequate safety systems that meet Occupational Safety and Health Administration standards and that these plans and specifications include a pay item for these same safety systems. li.U.B UI'IDER€lRQ~]\)D lJTIUTIES B. UnderQround Utilities - All distribution lines, cables, etc. for utilities other than those listed above shall be installed below ground within the subdivision. Transmission lines or major cables to provide utilities such as electric, telephone, and cable television to the area as a whole may be located above ground on the perimeter of the subdivision being served. The installation of these utilities shall conform to commonly accepted construction standards and be subject to review by the Director of Public Works Ser;\.'i€le~. Section 14-180 Drainage Studies and Engineering Certification 1 i.l'.).. PREUl\UN:.R'.' :DR\IN:.€lE Ann. YSIS CUlDEUI'IES A. Preliminary Drainage Analysis Guidelines - The purpose of a Preliminary Drainage Analysis is to determine the need for drainage facilities and/or drainage easements either within the proposed development or offsite. A Preliminary Drainage Analysis is required for every subdivision plat or a development requesting a building permit on a parcel which does not have a previously approved drainage analysis, unless the sit:! 8R~iReElr Director of Public Works has waived this requirement due to existing conditions. The Preliminary Drainage Analysis shall consist of the following information: 1. A topographical map drawn at a scale of I" = 200' which depicts the watershed that drains to and across the subdivision or development. The map must include the subdivision and an area extending a minimum of 200' in all directions from the proposed subdivision. Sheets shall be either 18" X 24" or 24" X 36" in size and may contain sheet to sheet match lines. The map must include contour lines at five (5') foot vertical intervals in terrain with a slope of two (2%) percent or more, or two (2') foot vertical intervals in terrain with a slope of less than two (2%) percent. Data from the City topographic Chapter 14 - Engineering Design Standards Page 14 - 38 Colleyville, Texas, Land Development Code maps will be acceptable where available. Data from USGS Quad sheets may be acceptable only where City topographic maps are not available. The datum for "0" topography shall be that of the United States Coast and Geodetic Surveyor the City of Colleyville GIS datum. The map shall indicate any offsite or adjoining areas outside the limits of the area being developed which are relevant to onsite drainage. Show all significant physical features such as proposed or existing drainage and utility easements, water bodies, streams, railroads, parks, and drainage ditches. Show location of existing utilities including gas and petroleum lines, electric, telephone and TV cable. Also, the location of any existing structures located within the area being proposed for development. The plan shall include the building footprint and parking areas when the Preliminary Drainage Analysis is prepared for a building permit. 2. Calculation of the drainage areas, time of concentration, and storm water runoff rate for the 2. 5. 10. 25. 50 and 100 year frequency storms. The design calculations shall include preliminary locations of drainage facilities. (0-00-1261/12/19/00) 3. Identification of special flood hazard areas as defined by the Flood Hazard Area Regulations Ordinance and as located by the current Flood Insurance Rate Map. 4. The Preliminary Drainage Analysis shall be sealed by a Registered professional Engineer licensed by the State of Texas. :DR'.In\GE STYDY ClHDEUI'JES 1 ~.lti.B B. DrainaQe Study Guidelines - A Drainage Study is required when it has been determined by the 6ity eFl~iReE:H Director of Public Works that the area being developed will require storm water drainage facilities or drainage easements either within the development or offsite. The following criteria shall be used for the developer's engineer to prepare a Drainage Study. 1. The study shall analyze the effect of the subdivision or the development on existing downstream drainage facilities. The study shall be sufficient to verify compliance with the drainage design criteria contained in this chapter. 2. The study shall include a topographical map as defined above in "Preliminary Drainage Analysis Guidelines." 3. Delineation and calculation of drainage areas together with proposed flow arrows shall represent flow patterns from runoff after all proposed improvements have been installed. Surface water drainage patterns shall be shown for each and every lot in the proposed subdivision and for each lot adjacent to the proposed subdivision. 4. In addition to those calculations required by the Preliminary Drainage Analysis, this study shall also include: a. Hydraulic calculations to each lateral, manhole, inlet and outlet structure on the pipe. Head losses shall be calculated as described elsewhere in this chapter. b. Inlet calculations utilizing the minimum time of concentration for the zoning type which is contributing the largest "CA" to the inlet. 5. If any portion of the proposed subdivision or its offsite improvements (including pipes or ditches) fall within the limits of a Federal Emergency Management Agency (FEMA) floodplain, additional backwater calculations may be required. Additional calculations in the form of a Conditional Letter of Map Revision will be required if: a. Any portion of the proposed subdivision is determined to be located within a FEMA Zone "A" floodplain; or b. Any portion of the proposed subdivision is determined to be located within a FEMA Zone "AE" Chapter 14 - Engineering Design Standards Page 14 - 39 Colleyville, Texas, Land Development Code floodplain and the overall subdivision (including all phases) is 5 acres or larger; or c. Any portion of the proposed improvements from a subdivision include dredging or filling within a FEMA designated floodway. 6. Backwater calculations shall comply with normally accepted standards as required by FEMA for application for a Letter of Map Revision (LOMR). In addition, the calculations must begin with a previously defined Base Flood Elevation (BFE). The calculations shall continue upstream through the project until the proposed BFE is within .01 feet of the existing BFE or the limits of the existing Zone 'A' have been reached. A LOMR will be required prior to issuing building permits. 1 ~.lti.C CERTIFIC!. TIS!'l C. Certification - All drainage studies and/or plans including those which are part of a standard construction plan submittal shall be sealed and signed by an engineer proficient in civil engineering and registered in the State of Texas. All drainage submittals shall include the following certifying statement by the "Engineer of Record". I a Professional Engineer r8!!jistere& licensed in the State of Texas have prepared this drainage study and/or plan in compliance with the latest published requirements and criteria of the . City of Colleyville, and have verified that the topographic information used in this study and/or plan is in i compliance with said requirements and is otherwise suitable for developing this workable plan of drainage which : can be implemented through proper subsequent detailed construction planning. I Signature .........................m......................... . P.E., (S~~I) :DI~Cl:..\.Il\IER QF l.UBIUTY 1 ~.I'.:D D. Disclaimer of Liability - The degree of flood protection required by this policy is considered reasonable for regulatory purposes and is based on scientific and engineering considerations. On rare occasions greater floods can and will occur and flood heights may be increased by man-made or natural causes. This policy does not imply that land outside the areas of street rights-of-way, drainage or flood plain easements will be free from flooding or flood damages. This policy shall not create liability on the part of the City of Colleyville, Texas or any official or employee thereof for any flood damages that result from reliance on this policy or any administrative decision lawfully made thereunder. Section 14-185 Amendments to This Chapter Reserved for listing of amendments to this Chapter. Ord. Number 0-00-1261 Date 12/19/00 0-01-1280 01/08/01 Chapter 14 - Engineering Design Standards Page 14 - 40 ORDINANCE 0-03-1403 AN ORDINANCE OF THE CITY OF COLLEYVILLE, TEXAS, AMENDING CHAPTER 14 - ENGINEERING DESIGN STANDARDS, OF THE LAND DEVELOPMENT CODE; PROVIDING A SAVINGS CLAUSE; PROVIDING A SEVERABILITY CLAUSE; PROVIDING A PENALTY CLAUSE; AND AUTHORIZING PUBLICATION. WHEREAS, the City Council of the City of Colleyville approved Ordinance 0-00- 1214 on April 18, 2000, to adopt the Land Development Code; and WHEREAS, the City Council of the City of Colleyville desires to amend certain portions of the Land Development Code; and WHEREAS, notice of a public hearing before the City Council was published in a newspaper of general circulation in Colleyville at least 15 days before such hearing. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec 1. Sec2. Sec3. Sec4. THAT Chapter 14 - Engineering Design Standards, of the Land Development Code, as amended, is hereby amended in its entirety to read as shown on the attached Exhibit "A". THAT Ordinance 0-00-1214, the Land Development Code, as amended, shall remain in effect, except where amended by this ordinance. THAT it is hereby declared to be the intention of the City Council that the phrases, clauses, sentences, paragraphs, and sections of this ordinance are severable, and if any phrase, clause, sentence, paragraph or section of this ordinance shall be declared unconstitutional by the valid judgement or decree of any court of competent jurisdiction, such unconstitutionality shall not affect any of the remaining phrases, clauses, sentences, paragraphs and sections of this ordinance, since the same would have been enacted by the City Council without the incorporation in this ordinance of any such unconstitutional phrase, clause, sentence, paragraph or section. THAT any person, firm or corporation violating any of the provisions of this ordinance shall be guilty of a misdemeanor and upon conviction thereof shall be fined a sum not to exceed Two Thousand Dollars ($2,000.00). Each and every day such violation continues Ordinance 0-03-1403 Page 2 of 2 shall constitute a separate offense and shall be punishable as such. Sec 5. THAT the City Secretary is hereby authorized and directed to cause publication of the descriptive caption and penalty clause hereof as an alternate method of publication provided by law. AND IT IS SO ORDERED. The first reading and public hearing being conducted on the 2003. day of The second reading and public hearing being conducted on the 2003. day of ATTEST: CITY OF COLLEYVILLE: Cynthia Singleton, TRMC City Secretary Mayor APPROVED AS TO FORM AND LEGALITY: Ross 1. Foster City Attorney Exhibit "A" Chapter 14 - Engineering Design Standards Colleyville Land Development Code Colleyville, Texas, Land Development Code Section 14-100 Purpose of Ihis Chapter The purpose of this Chapter is to establish minimum standards and construction details for all public facility improvements. Section 14-105 Authorization for Adoption of This Chapter The regulations contained in this Chapter have been adopted under the following authority: A. Chapter 212 - Municipal Regulation of Subdivisions and Property Development of the Texas Local Government Code, which authorizes a municipality to adopt rules governing plats and subdivisions of land within the municipality's jurisdiction. B. Chapter 51 - General Powers of Municipalities of the Texas Local Government Code, which authorizes a municipality to adopt ordinances, rules, or police regulations that are for the good government, peace, or the trade and commerce of the municipality. C. The Home Rule Charter of the City of Co/leyville, which authorizes the City Council to exercise all powers granted to municipalities by the Constitution or the laws of the State of Texas. Section 14-110 Applicability of This Chapter The provisions of this Chapter shall be applicable to all public improvements owned and maintained by the City of Colleyville and to any semi-public improvements owned and maintained by a property owner's association that are intended to serve and function as a public improvement. Section 14-115 Variances and Appeals A. The Director of Public Works may consider an alternative proposal of a regulation contained in this Chapter in order to achieve the best overall design. When considering such a proposal, the Director of Public Works shall determine that the approval, disapproval or modification will not be detrimental to the public safety, health, or welfare or injurious to other property and is consistent with sound engineering practices. The applicant shall provide information to support a claim that the public interest may be better served by an alternative proposal. B. Any person seeking approval of a development may appeal a decision of the Director of Public Works regarding the regulations contained in this Chapter by using the procedures described in Chapter 1 - General Provisions of this Land Development Code. Section 14-120 General Conditions A. "COG" and "TXDOT" Specifications - All drawings and details contained in Chapter 15 - Public Works Construction Details which include references to "item numbers", "specs" and "types" shall be governed by the latest version of "Standard Specifications for Public Works Construction, North Central Texas" of the North Central Texas Council of Governments ("COG"), with all amendments thereto, and shall constitute the technical specifications, except as amended by this Land Development Code, and made a part thereof, but not physically bound within this document. Streets shall be designed in accordance with Chapter 14 - Engineering Design Standards Page 14 - 1 Colleyville, Texas, Land Development Code the most current edition of The Texas Department of Transportation's Highway Design Division Operations and Procedures Manual, AASHTO's A Policy on Geometric Design of Highways and Streets, and the Transportation Research Board's Highway Capacity Manual. B. Acceptance of Improvements - No public improvements shall be accepted by the City or its representatives, unless and until such improvements conform to this Land Development Code and all other applicable standards as prescribed by the City of Colleyville. All streets, alleys, sidewalks, drainage-ways, signage, water and sewer lines and all other public improvements shall be designed, placed and constructed in accordance with the design criteria contained in this Land Development Code. C. Plan Review and Inspection Fees - Prior to the acceptance by the City of any public improvements, the developer shall pay the City a plan review fee and an inspection fee as follows: 1. Engineering Plan Review Fee - 2% of the actual cost of the public improvements 2. Engineering Inspection Fee - 3% of the actual cost of the public improvements D. Citv-Developer Aqreements 1. Requirement - When it is proposed that the City will share in the costs with a developer for the construction of public improvements, no public improvements shall be constructed within a development, unless and until a City-Developer Agreement has been approved by the City Council. Where the public improvements are a requirement of a subdivision plat approval, the City-Developer Agreement shall be submitted to the City Council for approval at the same time as the plat submittal, or as soon thereafter as practical. (0-00-1261/12/19/00) 2. City Participation - The City may share in the costs with a developer for constructing public improvements relating to a development, provided a City-Developer Agreement has been approved by the City Council in accordance with this Section. The limits of City participation shall be expressly established in the agreement at a level not to exceed thirty (30) percent of the total contract price. Under the agreement, the developer shall construct the public improvements and the City shall participate in the costs. Where a developer is requesting City participation in the construction of a public facility and the total participation cost by the City exceeds twenty-five thousand ($25,000) dollars, the procurement procedures specified in the Texas Local Government Code for public improvements shall be used by the developer. All records to the developer's cost of constructing the public improvements shall be maintained and made available for inspection by the City. (0-00-1261/ 12/19/00) 3. Construction Plans - It shall be the responsibility of the developer's engineer to prepare all engineering construction plans and contract documents for construction of the project for the use of the City and the contractor. (0-00-1261/12/19/00) 4. Performance Bond - Where a City-Developer Agreement has been authorized, the developer shall execute a performance bond for the construction of the public improvements which shall include any City participation to ensure their completion. (0-00-1261/12/19/00) 5. Authorization to Proceed - On projects not requiring a City-Developer Agreement, the developer may proceed with the construction of the public improvements after the City has issued a letter authorizing the developer to proceed with the construction, provided the engineering construction plans have been approved by the Director of Public Works. All construction shall be in accordance with the applicable sections of this Land Development Code. The developer may select his own contractor subject to the contractor executing the necessary bonds with the City and payment of the inspection fees required for each portion of the public facilities. (0-00-1261/12/19/00) Section 14-125 Construction Plan Requirements The purpose of this Section is to specify the minimum construction drawing requirements for all public improvement projects, including public improvements associated with a proposed subdivision or commercial development. All construction plans for public water, sanitary sewer, street, drainage and traffic improvements Chapter 14 - Engineering Design Standards Page 14 - 2 Colleyville, Texas, Land Development Code shall be designed, signed, sealed, and dated by a Registered Professional Engineer licensed in the State of Texas. All construction plans or drawings must be accompanied by a Geotech Report signed, sealed, and dated by a Registered Professional Engineer licensed in the State of Texas. Plans and drawings shall adhere to the requirements in this Section and be furnished in the format listed herein: A. General Requirement - No construction of any public improvement shall commence, unless and until the construction plans for the proposed public improvement has been approved by the Director of Public Works or designee. B. Number of Copies - No construction of any public improvement shall commence, unless and until the construction plans for the proposed public improvement has been approved by the Director of Public Works or designee. C. Cover Sheet 1 . project title 2. property legal description, if applicable 3. city name 4. vicinity map 5. owner, engineer, and surveyor name, address and telephone number 6. project title in small print placed vertically along the right border 7. sheet index 8. signature block for City approval D. Copv of Current Plat - When construction plans are related to a new subdivision or a commercial development, a copy of the current plat shall be bound with the construction plans. The signed plat shall be bound with the as-built drawings. E. Drainaqe Area Map - The drainage area map is critical to all drainage designs, since the ultimate layout, sizing and hydraulic analysis is dependent upon a thorough review of the proposed development. This map should be accompanied with all drainage calculations. The Drainage Area Map must show the physical features of the site that either exist or are proposed, including the existing and proposed contours, existing and proposed storm sewers, and/or other drainage facilities. Commercial projects should include the locations of buildings, flatwork and pavement. F. Site Plan - The developer of a commercial project shall submit a site plan indicating the location and width of all proposed and existing street and driveway approaches noting the back-of-curb radii. G. Utilitv Plan - This drawing shall indicate the location and size of all existing and proposed water and sanitary sewer lines with adjacent existing or proposed top of curb grades. Show the location of all existing and proposed fire hydrants adjacent to the site including the maximum coverage radius of each as outlined in later sections of this manual. H. Plan and Profile Sheets - Plan and profile drawings shall be required for roads, sewers, storm sewers, channels, flumes, and water lines twelve (12") inches in diameter and larger. Stationing shall be generally left to right and with stationing beginning at the downstream end for all sewers, storm sewers, and channels. Stationing shall be included on the plan view as well as the profile for all roads, water, sewer, storm sewer and channel sheets. Elevations shall be calculated and provided on all profiles as indicated below. 1. Straight grade - provide elevations at a maximum interval of 50 feet. 2. Vertical curve - provide elevations at the beginning and ending points and at a maximum interval of 25 feet in between. I. Plan & Profile Sheet Size - Plan and profile sheets shall not exceed twenty-four (24") inches wide by thirty-six (36") inches long. Horizontal scale shall be one (1") inch equals fifty (50') feet or larger, i.e. 1" = 40'. Vertical scale shall be one (1") inch equals five (5') feet or larger. J. Details - Drawing details shall be included with all construction plans to clarify proposed construction Chapter 14 - Engineering Design Standards Page 14 - 3 Colleyville, Texas, Land Development Code specifications and said details shall be consistent with Chapter 15 of this Land Development Code. K. Plottino Drainaqe Features - Appropriate hydraulic grade line or water surface profile shall be plotted with all drainage designs. Capacity, design discharge, velocity, and velocity head shall be noted on each segment of a drainage facility in the profile whenever one or more of these parameters changes. L. Erosion Control Plan - The developer of a subdivision or a commercial project shall submit an erosion control plan in accordance with the requirements of Chapter 12 - Erosion Control. M. Storm Water Pollution Prevention Plan - The developer of a subdivision or a commercial project shall submit a storm water pollution prevention plan in accordance with the requirements of the Texas Commission on Environmental Quality. N. Street Sion Plan - showing the location of all proposed street name signs and traffic control signs. The street sign plan shall include an elevation view of each street sign indicating the type and color of each sign. All signs shall comply with the requirements of the latest edition of the Texas Manual on Uniform Traffic Control Devices. Refer to street sign standards, located elsewhere in this Land Development Code (Section 14-145). O. City Review and Approval Process - All construction plans for public improvements shall be reviewed by city staff for compliance with this Section and with any applicable guidelines of other agencies. City staff shall provide written comments to the developer and the developer shall respond to all city comments. The Director of Public Works, or designee, shall not approve any construction plans until all comments have been resolved and the construction plans determined to be acceptable to the city. All approved construction plans shall be signed by the Director of Public Works, or designee, and no construction work shall commence until a pre-construction meeting has been held and a letter of authorization to proceed has been issued by the Director of Public Works. Development projects which have not started within one year from the date of approval of the construction plans shall require a new review. Section 14-130 Street Design Criteria A. Rioht-of-Wav Widths - The right-of-way widths for any proposed street shall be designed for the intended use and anticipated traffic volume at optimum development of the area served. Additional right-of-way may be required at street intersections and to provide for left and right turn lanes at high-volume intersections. The following table shall be used as a guide in determining right-of-way widths. Local R2U 50 (2) 15 30 2 Cul-de-sac R2U 50 (3) 18 36 (3) 2 Minor Collector C2U 75 12 42 2 wI 9' parking or 3 wlo arkin Major Collector (two lane) C3U 75 12 42 2 wI 9' parking or 3 wlo arkin Major Collector (four lane) C4U 80 12 48 4 undivided Minor Arterial M4D 95 13 52 4 divided P4D 120 13 52 4 divided Prima Arterial \ S. H. 26 P6D 120 12 76 6 divided (1 ) Street classification refers to the functional classification shown on the Master Thoroughfare Plan. Chapter 14 - Engineering Design Standards Page 14 - 4 Colleyville, Texas, Land Development Code (2) A local street having a total length in excess ot one thousand two hundred (1,200) teet or serving more than thirty (30) dwelling units may be required to provide a right-ot-way width ot not less than sixty (60) teet. (3) A cul-de-sac street exceeding 600 teet in length shall have a 56' right-ot-way and 36' ot pavement. B. Desion Speed and Maximum Grade - All streets shall be designed to conform to the following parameters: Local 30 8 0.5 ...."1" ................................. i......................................... C2.1.1.~~2.~..m.mm.: 30 6 0.5____Q':l_~.!~I.1_e or center 12' Arterial 40 4 0.5! One lane in each direction (1) The Director ot Public Works may approve an alternate design. Section 14-135 Driveway Spacing and Design Standards A. Residential Construction - Residential driveway approaches shall be constructed of six (6") inch thick three thousand five hundred (3,500) psi compressive strength concrete reinforced with #3 steel bars on eighteen (18") inch centers each way, with #4 bars doweled into the existing concrete paving.. Residential driveways shall be constructed with the return curbs having a rolled face disappearing at the sidewalk and joining the street curb. B. Commercial and Industrial Construction - Commercial and industrial driveway approaches shall be constructed of six (6") inch thick three thousand five hundred (3,500) psi compressive strength concrete reinforced with #4 steel bars on eighteen (18") inch centers each way, with #4 bars doweled into the existing concrete paving. Commercial and industrial driveways shall be constructed with the return curbs having a rolled face disappearing at the sidewalk and joining the street curb. C. Drivewav Approach Depth - The driveway shall begin at the street curb and extend to the property line or to a point nine and one-half (9.5') feet from the back of the curb, whichever is greater. The drive approach shall be constructed such that the height of the drive approach at the property ROW, with a typical nine and one-half (9.5') foot parkway, shall be two and one-half (2-1/2") inches higher than the top of the curb. The tangency point of a driveway curb shall be a minimum of ten (10) feet from a storm water inlet. D. Drivewav Approach Widths and 5pacino - The criteria contained in the following table shall be the minimum and/or maximum standards to be applied in spacing and designing driveways on public streets. For the purpose of this regulation, driveway width shall be measured at the property line. The Director of Public Works may modify these standards based on anticipated traffic flow and in accordance with sound traffic engineering practices. To implement the standards contained in the following table, subdivision plats for new commercial developments shall be required to provide cross-access easements. (See table on next page) Chapter 14 - Engineering Design Standards Page 14 - 5 Colleyville, Texas, Land Development Code Driveway Curb Radius 35' 35' 35' 35' 20' 20' ......................................... 20' 30' Driveway Spacing (centerline) Minimum Distance from Driveway to Intersection (pi to pi) Arteria I Local Minor Coil. I\t1tlj()rggll. Arterial nl n/a n/a ................-........... n/a n/a n/a E. Provision for Joint Approaches - Driveway approaches shall be located entirely within the frontage of the premises they serve except that joint, or cooperative, driveways with adjoining property holders may be permitted by the Director of Public Works. When a joint drive approach is proposed by a developer, the request must be made by all interested parties and/or all property owners involved. F. Circular Driveway Approaches at Street Intersections - The Director of Public Works may approve a circular drive on a corner lot where both streets are residentially classified. G. Anqle of Driveway Approach - The angle of the driveway approach with the curb line shall be ninety (90) degrees. H. Sidewalk to be Removed - Where a driveway approach is to be built, any existing sidewalk located within the proposed driveway location shall be removed and the entire area replaced as a driveway. The drive approach shall extend to the property line. I. Driveways Crossinq Bar Ditches 1. Culvert Size - The minimum culvert pipe size shall be 18" diameter. However, an engineered design that provides for a larger culvert pipe size may be required by the developer where the Director of Public Works determines that additional drainage capacity may be required. The ends of all culvert pipes shall be cut at a 6: 1 slope. 2. Radius - Driveways shall be constructed with the return curbs joining the edge of pavement at the street with a minimum ten-foot (10') radius. 3. Slope - The maximum slope from the edge of driveway to the top of the culvert pipe shall be 6: 1. The sloped area around the end of the culvert pipe shall be sodded or hydro-mulched to resist erosion. 4. Cross Slope - The minimum cross slope on the drive shall be 1/8 inch per foot. The minimum longitudinal slope between the edge of pavement at the street and the valley over the culvert pipe shall be 1/4 inch per foot. Chapter 14 - Engineering Design Standards Page 14 - 6 Colleyville, Texas, Land Development Code 5. Maintenance - Future maintenance of the drive approach and culvert pipe is the responsibility of the property owner. 6. Grading - During the drive approach installation, all ditch grading upstream and downstream of the proposed driveway culvert is the responsibility of the property owner. J. General 1. Driveway Approaches at Pedestrian Crossings - Driveway approaches shall not be located in street intersections or at established pedestrian crossings. 2. Driveway Approaches at Obstructions - Driveways shall be kept at a minimum of five (5') feet away from obstructions such as street light posts, fire hydrants, traffic signals, etc. 3. Accumulative Width of Approaches - Driveway approaches shall not occupy more than forty (40%) percent of the frontage of a lot or tract. Section 14-137 Fire lane Requirements (2000 IFC Section 503) A. Plan Approval - Plans for fire lanes shall be submitted to the Fire Marshal Division for review and approval prior to construction. Repainting of existing markings does not require plan review unless changes are to be made. B. Obstructions Prohibited - Fire lanes shall be kept clear and unobstructed at all times. Marking shall be repainted as necessary to maintain readability. C. SiQnaqe - Where required by the Fire Marshal, approved signs or other approved notices shall be provided and maintained to identify fire lanes and prohibit obstructions. D. Where Required - Fire lanes shall be provided when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. E. Certain Roadwavs Not Considered Access - Heavily traveled public roadways are not considered for fire apparatus access due to the dangers involved with operating fire apparatus in close proximity to moving traffic. F. Access to Serve All BuildinQs - Fire lanes shall be provided to serve all buildings through parking areas to service entrances, loading areas, trash collection areas, and other areas deemed necessary to be available to fire and emergency vehicles. G. Drivewavs Included - Fire lanes shall include driveways leading onto a public street. H. Fire Lane Width - Fire lanes shall have an unobstructed width of not less than 24 feet and an unobstructed vertical clearance of not less than 14 feet. I. Turninq Radius - Fire lanes shall have a minimum inside turning radius of thirty (30) feet and a minimum outside turning radius of fifty (50) feet. J. All-weather Surface Required - Fire lanes shall be designed and maintained to support the imposed loads of fire apparatus and shall be provided with an asphalt or concrete surface so as to provide all- weather driving capabilities. K. Construction Specifications - Fire lanes shall be constructed of seven (7) inch concrete with #3 rebar on eighteen (18) inch centers on chairs over a modified subgrade as per the Geotechnical Soils Report; or seven (7) inch asphalt over a modified subgrade as per the Geotechnical Soils Report. The construction shall be capable of supporting a minimum of 65,000 pounds gross vehicle weight. Chapter 14 - Engineering Design Standards Page 14 - 7 Colleyville, Texas, Land Development Code L. Maximum Dead-end Lenqth - Dead end fire lanes in excess of 150 feet in length shall be provided with an approved area for turning around fire apparatus. Dead end fire lanes more than 150 feet in length but less than 700 feet in length shall provide one of the following turn-around configurations. Dead end fire lanes in excess of 700 feet in length shall be submitted to the Fire Marshal for review and approval. 30' R TYP. 24' -. ..- ---. ..... 24' 100' DIAMETER CUL-DE-SAC ACCEPTABLE ALTERNATIVE TO 120' HAMMERHEAD -+ 24' :~R\ + 70'. ... 70' .. I~I~I 24~ . +24' 120' HAMMERHEAD ACCEPTABLE ALTERNATIVE TO 120' HAMMERHEAD M. Fire Lane Stripinq - Fire lanes shall be marked with a six (6) inch wide continuous bright red stripe on both sides. Striping shall be on the curb face where curbing is located at the edge of fire lanes. White 4 inch high lettering with a one (1) inch stroke centered on red stripe shall read: NO PARKING - FIRE LANE. This lettering shall be painted every (15) feet measured from the end of one lettering group to the beginning of the next group with a one (1) foot space between "No Parking" and "Fire Lane". Red paint shall not be used for any parking lot marking other than fire lanes. Fire lane markings are subject to the field inspection of the Fire Marshal. Section 14-140 Street Improvement Specifications A. General - Streets shall be constructed or reconstructed using either hot-mixed asphaltic concrete pavement sections or reinforced portland cement concrete pavement sections that meet or exceed the minimum specifications of this Land Development Code. The developer requiring street construction shall provide a geotechnical report, sealed by a Registered Professional Engineer licensed in the State of Texas, containing recommendations for subgrade thickness and content. The minimum subgrade and pavement thickness shall be in accordance with the specifications contained in this Section. For the purpose of this Section, a collector street shall be defined as all those collector streets shown on the Master Thoroughfare Plan and those streets internal to a subdivision which provide connection between local residential streets and the major collector network and which are designed to accommodate more than 500 vehicles per day. B. Hot-Mixed Asphaltic Concrete Pavement Sections 1. Local Streets (including cul-de-sac) Chapter 14 - Engineering Design Standards Page 14 - 8 Colleyville, Texas, Land Development Code a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Five (5") inches Type "A" or "B" hot-mixed asphaltic concrete placed in three (3) lifts. The bottom lift shall extend to one (1') foot beyond the back of curb line. d. Two (2") inches Type "D" hot-mixed asphaltic concrete placed in one (1) lift. 2. Collector Streets a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Six (6") inches Type "A" or "B" hot-mixed asphaltic concrete placed in three (3) lifts. The bottom lift shall extend to one (1 ') foot beyond the back of curb line. d. Two (2") inches Type "D" hot-mixed asphaltic concrete placed in one (1) lift. 3. Arterial Streets a. Eight (8") inches thick (minimum) stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Eight (8") inches Type "A" or "B" hot-mixed asphaltic concrete placed in four (4) lifts. The bottom two lifts shall extend to one (1 ') foot beyond the back of curb line. d. Two (2") inches Type "D" hot-mixed asphaltic concrete placed in one (1) lift. 4. Stabilized Subgrade for Hot-Mixed Asphaltic Concrete Pavements - The basic design of the asphaltic pavement sections for streets and roads assumes average subgrade conditions which in all cases shall be stabilized to not less than the thickness shown herein with lime or cement at a minimum rate of 6% of the necessary volume or that recommended by an approved and acceptable geotechnical report submitted to the City by a licensed Geotech Engineer. Classification of the subgrade for evaluating the supporting qualities shall generally apply to the top twelve (12") inch layer of soil measured down from subgrade surface. Where combinations of conditions indicate special problems, such as springs or seepage, drastic material changes from point to point, etc., that reduce the existing subgrade below average, appropriate remedies designed by a Registered Professional Engineer based upon actual onsite observations and tests shall be included to correct the particular condition involved. In all cases, the requirements set forth in this criteria are minimum and the City reserves the right to require further additional testing (such as California Bearing Ratio), precautions or treatments consistent with sound engineering practice when necessary to provide for other conditions not specifically covered by this criteria. Compaction of stabilized subgrade shall be 95% standard proctor density. C. Reinforced Portland Cement Concrete Pavement Sections 1. Local Streets (including cul-de-sac) a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Six (6") inch thick portland cement concrete, reinforced with #3 reinforcing bars having a spacing of eighteen (18") inches center to center both ways. 2. Collector Streets a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Seven (7") inch thick portland cement concrete, reinforced with #4 reinforcing bars having a spacing of eighteen (18") inches center to center both ways. 3. Arterial Streets Chapter 14 - Engineering Design Standards Page 14 - 9 Colleyville, Texas, Land Development Code a. Six (6") inch thick stabilized subgrade, twelve (12") inches past the back of curb line. b. Prime (or cure) coat. c. Eight (8") inch thick portland cement concrete, reinforced with #4 reinforcing bars having a spacing of eighteen (18") inches center to center both ways. 4. Basic Requirements For All Reinforced Concrete Pavement - The basic design of reinforced concrete pavement sections for streets and roads assumes poor subgrade conditions which shall be stabilized with lime or cement at a minimum rate of 6% of the necessary volume or that recommended by an approved and acceptable geotechnical report submitted to the City by a licensed Geotech Engineer. In all cases, the requirements set forth in this criteria are minimum and the City reserves the right to require further additional testing (such as California Bearing Ratio), precautions or treatments, when necessary, consistent with sound engineering practice to provide for other conditions not specifically covered by this criteria. 5. Concrete for Pavement - Concrete for pavements shall be Class "A" and consist of five (5) sacks (minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural strength of five hundred pounds per square inch (500 PSI) and a twenty-eight (28) day compressive strength of three thousand five hundred pounds per square inch (3,500 PSI). Composition and placement of reinforced concrete pavements shall be in accordance with the applicable requirements of Item 360 of the Texas State Department of Transportation Standard Specifications. Coarse aggregate shall be either number 2 or 3. Cement for the mixture shall be Type I portland cement. All hand pours are to be six (6) sacks minimum of portland cement for each cubic yard of concrete mix with a compressive strength of three thousand five hundred pounds per square inch (3,500 PSI). D. Curb and Gutter Specifications All streets shall be provided with reinforced portland cement concrete curbs and gutters in accordance with the following specifications. 1. Curbs and gutters a. Curb rolls shall be six (6") inches wide and not less than six (6") inches high nor more than seven (7") inches high. b. Curb and gutter bases shall not be less than twenty-four (24") inches wide and provide a minimum gutter width of eighteen (18") inches (see detail P-4A and P-4B). c. Gutter depths for hot-mixed asphaltic concrete pavement shall be five (5") inches for local streets and six (6") inches for collector and arterial streets. Gutter depths for reinforced portland cement concrete pavement shall be the same as the pavement thickness. 2. Reinforcement Steel - Reinforcement shall be provided by three (3) number three (#3) steel reinforcing bars by placing one (1) bar in the curb roll and two (2) bars in the curb and gutter base. This reinforcement is in addition to reinforcement in portland cement concrete pavements. 3. Concrete Classification - Concrete for curbs and gutters shall be Class "A" and consist of five (5) sacks (minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural strength of five hundred pounds per square inch (500 PSI) and a twenty-eight (28) day compressive strength of three thousand five hundred pounds per square inch (3,500 PSI). 4. Installation Procedure - Curb and gutter for hot-mixed asphaltic concrete pavements shall be placed on the first two (2") inch lift of asphaltic paving. For reinforced portland cement concrete pavements, the curb and gutter base shall be placed monolithically with the pavement. The curb roll shall be placed monolithically with the pavement or added separately. Curb rolls added separately shall be provided with number three (#3) reinforcing bar stirrups spaced twenty-four (24") inches center to center which extend to within three (3") inches of the bottom of the pavement. 5. Driveway Cuts - All driveway entrances constructed in existing curb and gutters shall be saw-cut at the curb return on both sides of the driveway and eighteen (18") inches into the street. After work is Chapter 14 - Engineering Design Standards Page 14 - 10 Colleyville, Texas, Land Development Code completed, the street sidewalk shall be repaired and it shall be the responsibility of the party installing the driveway. F. Street Drainaqe - The following drainage conditions shall be observed: 1. All roads shall be a crowned or roof top section so as to provide proper drainage. 2. All plats shall depict the flow of drainage with arrows sufficient to show predicted path. 3. An explanation and depiction shall be attached to show outflow and inflow availability on high flow areas. Adjoining property where inflow originates or outflow exists must be attached to insure compliance with drainage or excessive run-off factors. 4. No plat shall be considered for approval unless accompanied by a complete set of construction drawings that show the drainage areas and flow calculations. 5. The contractor/developer will assume all responsibility to disperse excess run-off so as not to exceed previous disbursements to the satisfaction of the city. G. Street Construction 1. The street portion of the plat must be approved by the Planning and Zoning Commission or the Approving Body, Fire Chief, Police Chief and Director of Public Works. 2. The street type code must be plainly visible on the plat and marked so that no misunderstanding can result. 3. A performance bond must be presented to the City Secretary or duly appointed representative for an amount equal to the contract by the contractor doing the project. A maintenance bond equal to 10% of the contract price will be in effect for two (2) years after acceptance by the City. 4. No work shall commence without the issuance of an authorization of construction letter. 5. When Perimeter Street Escrows are required the following items shall be included in the fee calculations. a. Paving b. Subgrade stabilization c. Curb and gutter d. Sidewalk (or pathways where applicable) e. Excavation f. Utility relocation (20% of paving) g. Storm sewer improvements (20% of paving) h. Engineering (12% of the total of items a - g) i. Contingency (15% of the total of items a - h) H. Streets to be Trenched - When a public street is cut or trenched, the street shall be repaired according to this paragraph. A three (3) sack per cubic yard concrete mixture shall be filled-in beginning one (1') foot above the object the street was cut for and continue until one (1') foot from the top of the street or reaching the plane of the sub-base compacted to 95% Standard Proctor. The base and topping shall be the minimum required for that type of street. I. Forfeiture Clause - If in the opinion of the Director of Public Works or his duly appointed representative, the street project does not comply with the type code applied to the street(s), the performance bond shall be forfeited to the amount necessary to correct the substandard section if that section(s) is not corrected by the contractor. 1. All areas in question by the City that cannot be reconciled by the contractor will be examined by an independent testing firm, agreed upon by both parties, and its findings will prevail. Chapter 14 - Engineering Design Standards Page 14 - 11 Colleyville, Texas, Land Development Code 2. The cost of this testing will be borne by the incorrect party. 3. The City of Colleyville reserves the right to make tests or checks at any place or any time there is a question of ordinance compliance. 4. Any developer or contractor found to willfully and knowingly misrepresent or disregard the regulations herein stated shall forfeit all rights and permits in the City of Colleyville, Texas, with a majority vote of the City Council. J. Texas Department of Transportation Hiqhwav Specifications - All specifications not specifically provided for elsewhere in this Chapter are referenced to the Texas Department of Transportation Standard Specifications For Construction of Highways, Streets and Bridges, 1993, AASHTO's A Policy on Geometric Design of Highways and Streets, and the Transportation Research Board's Highway Capacity Manual. 1. Item 260 Lime Treated Subgrade - Lime used shall be Type "A" hydrated lime. The placement and construction of the subgrade shall be done in accordance with the applicable requirements described in Item 260 of the Texas State Department of Transportation Standard Specifications. 2. Item 270 Cement Treated Subgrade - Cement used shall be Type 1 portland cement. The placement and construction of cement treated subgrade shall be done in accordance with the applicable requirements described in Item 270 of the Texas State Department of Transportation Standard Specifications. An asphaltic membrane of RC-250 asphalt shall be applied as a cure coat. An alternate method of wet curing is also acceptable. 3. Item 310 Prime Coat - Asphalt material for prime coat shall be EA-HVMS. The placement of prime coat shall be described in Item 310 of the Texas State Department of Transportation Standard Specifications. Prime coat shall be placed on all lime treated subgrade at a rate of not less than 0.15 nor more than 0.25 gallons per square yard. 4. Item 340 Hot-Mixed Asphaltic Concrete Pavement - The composition and placement of hot-mixed asphaltic concrete pavement shall be in accordance with the applicable requirements of Item 340 of the Texas State Department of Transportation Standard Specifications. The asphalt for paving mixture shall be AC-20 forming from 4.5 to 6.0 percent of the mixture by weight. The asphalt for use as a tack coat under Item 340 shall be either RC-250 or EA-HVRS. K. Concrete Pipe - All concrete pipe used for drainage purpose on City streets shall be reinforced. L. Lime Treated Subqrade - Lime treatment shall extend ten (10') feet, if feasible, beyond the completed street when a future street is proposed to be built to assure proper conformity. Section 14-145 Street Signs and Traffic Control Signs A. General Requirement - Street name signs and traffic control signs shall be required for all street intersections. Installation of signs shall be performed by City work crews after payment to the City has been received from the developer for the installation costs. The Director of Public Works shall provide the developer with a cost estimate for all street signs associated with a development. The cost estimate shall include material and labor costs. 1. The Director of Public Works may require the installation of temporary street signs by the developer. B. Location - All signs shall be located in accordance with the Texas Manual on Uniform Traffic Control Devices. Street signs shall be furnished and installed by the subdivider for all intersections within or abutting the subdivision. C. Standards - All signs shall conform to the standards as set forth in the Texas Manual on Uniform Traffic Chapter 14 - Engineering Design Standards Page 14 -12 Colleyville, Texas, Land Development Code Control Devices. All road identification signs are to have a blue background with white reflective lettering. D. Installation - The sign pole shall be buried to a minimum depth of two (2') feet and placed in a twelve (12") inch diameter concrete filled posthole. The pole shall be tall enough to accommodate all applicable signs. The bottom of all signs shall be located seven (7') feet above the finished grade of the travel surface. E. Approval - The developer shall submit a list of signs to be placed and a graphical representation of the signs for review by Director of Public Works prior to installation. F. Custom Siqns - The Director of Public Works may approve custom-made street signs and custom-made sign poles, provided the Director of Public Works has executed a written agreement with a party responsible for the maintenance and replacement of such signs or sign poles. Section 14-150 Sidewalk & Pathways Specifications A. Permit Required - No person shall construct, reconstruct, alter, repair, remove or replace any sidewalk or pathway on any public property within the City Limits without first obtaining a permit from the building permit office, unless the sidewalk or pathway is included on the construction plans of an existing approved permit. B. Maintenance Bond - No such permit shall be approved until proof of bonding coverage has been submitted to the City and a two (2) year maintenance bond in the amount of 10% of the total cost of construction covering the sidewalk or pathway is in full force and effect at the time of the permit approval. Such bond shall not be valid unless persons doing the work are covered by the bond. Such bond may cover other work done by the applicant. The Director of Public Works may waive the maintenance bond requirement for repair to an existing sidewalk or pathway. C. Inspection Required - All work done in construction, reconstruction, alteration, repair, or removal or replacement of sidewalks or pathways shall be inspected by the city inspector to assure compliance with these regulations. When other public improvements are required, final acceptance of all other improvements shall not be made until sidewalks or pathways are approved. D. Minimum Sidewalk or Pathway Width - All sidewalks shall be a minimum of four (4') feet in width, except a sidewalk located within or abutting a collector street, or larger, as shown on the Master Thoroughfare Plan, which shall not be less than five (5) feet in width. All sidewalks and pathways shall be constructed in the area between the curb or grade line of the public street and the abutting property line unless the pathway is situated within a dedicated pathway easement or right-of-way. The edge of the sidewalk or pathway shall generally be parallel with the curb line and be situated no more than one (1 ') foot from the abutting property line. The Director of Public Works may approve a plan to alter the location of a sidewalk to preserve a tree or for aesthetic purposes. One additional foot of width shall be added to a sidewalk that abuts a street curb. The widths of all sidewalks and pathways shall be in accordance with the following table, which are further referenced in Chapter 15 - Public Works Construction Details. ...!YP~..."~"..... .m.....!YP~...::.Eln ..... .. . mmm.!YPE.l':g':mm .m.!YPE.l::P"m .. T pe "E" 4.0 ft. . .... ...........~........... . ...................................... 5.0 ft. . ..................................................... 8.0 ft. .......................................... 10.0 ft. 12.5 ft. E. Construction Materials - Sidewalks shall be constructed of portland cement concrete (minimum thickness four (4") inches). Pathway system sidewalks shall be a minimum thickness of five (5") inches. Concrete for sidewalks and pathways shall be Class "A" and consist of five (5) sacks (minimum) of portland cement for each cubic yard of concrete mix and have a seven (7) day flexural strength of 500 pounds per square inch (500 PSI) and twenty-eight (28) day compressive strength of 3,000 pounds per square inch (3,000 Chapter 14 - Engineering Design Standards Page 14 - 13 Colleyville, Texas, Land Development Code PSI). Reinforcement shall be in accordance with the construction detail contained in Chapter 15 - Public Works Construction Details. In such cases, reinforcements shall be #3 steel deformed reinforcing bars on eighteen (18") centers. F. Architectural Barriers Act - All sidewalk/street intersections shall be constructed so as to provide a ramp that complies with the Architectural Barriers Act. Barrier free ramps shall be provided for access to the street. The following specifications shall apply: 1. Ramp to be minimum four (4') feet in width. 2. Ramp to be constructed with Class "A" concrete. 3. Ramp concrete thickness shall be the same as the street (six (6") inch normal residential). 4. #3 bars shall be used for reinforcement (twenty-four (24") inch on centers). 5. Curb return shall match existing curb height of the street and taper to the connecting walk with a 1- foot radius. 6. Street shall be blocked out (max. twelve (12") inches) and dowels installed. 7. Saw joints shall be made one and a half (1 1/2") inch minimum depth and sealed with silicone joint sealant material. 8. Subgrade shall be prepared to a minimum depth of six (6") inches. 9. At no time shall the walk running parallel to the street be altered. 10. Surface of walk shall be coarse and ribbed to provide extra traction (see detail P-8). Where the above specifications do not apply or have jurisdiction, refer to the specifications from the American Disabilities Act. Section 14-155 Street lighting A. General Reauirement - Street lights shall be installed at all intersections, at the end of all cul-de-sac streets, and at additional locations in accordance with the following table: Wood or metal 30 feet B. Spacina - The number of required street lights shall be equal to the total linear footage between street intersections divided by the required spacing. Fractions of street lights shall be rounded to the next whole number. C. Intervals - Street lights shall be placed at approximately equal intervals between intersections and shall be subject to the approval of the Director of Public Works. D. Desian - Cobra head lamps shall be provided on standard street lighting fixtures, except that other lamp types may be permitted where custom lighting is approved by the Director of Public Works. E. Custom liahtina - The subdivider may elect to provide custom lighting lieu of the required standard street lighting, subject to the approval of the city engineer. F. Custom liahtina Maintenance - If a subdivider elects to provide and install custom lighting, a homeowner's association (or some other such private entity) shall be created which will be perpetually liable for all costs associated with the maintenance of the lighting fixtures. Where the city is not liable for the costs of electrical energy from the custom lighting as provided in this subsection, the homeowner's association shall also be liable for the electrical energy costs of the custom lighting. Chapter 14 - Engineering Design Standards Page 14 - 14 Colleyville, Texas, Land Development Code Section 14~160 Water System Improvements A. General - This section pertains to general design requirements for water distribution system construction in the City of Colleyville. All water lines shall be sized and designed in accordance with the City of Colleyville Water Distribution System Master Plan or as determined by the Director of Public Works. In the absence of specific standards, all water supply, distribution, pumping, and storage improvements shall be designed in accordance with the most current standards of the American Water Works Association or the Standard Specifications for Public Works Construction of the North Central Texas Council of Governments or criteria adopted by the Texas Administrative Code, Chapter 290, "Water Hygiene". B. Line Sizes & Locations 1. Standard water line sizes are, S inch, 10 inch, 12 inch, 16 inch, 20 inch, and 24 inch diameter. Other sizes may be approved by the Director of Public Works. 2. All water lines shall be looped. Dead end lines shall not exceed 600 feet, unless approved by the Director of Public Works. No services shall be allowed on a dead end line. 3. Water lines shall be located within the parkway. Along State Highways, water lines are required on both sides of the roadway. New water lines crossing existing streets shall be placed by boring. A casing shall be required under major and minor collector roadways, arterial roadways and Highway 26 (Colleyville Blvd.). Open cut excavation will not be allowed to cross existing streets, unless approved by the Director of Public Works. 4. Easements for water line construction shall meet the following requirements: a. The easement width shall be a minimum of 15 feet. b. In areas where multiple easements exist the easement may need to be wider as specified by the City. 5. All piping with mechanical couplings, push-on, or similar joints subject to internal pressure shall be designed with blocking, anchors, and restraining harnesses to preclude separation of joints. 6. Water lines for multi-family, commercial and industrial fire protection lines shall be dedicated to the public, unless the system is isolated from the public system by a detector check. All water lines shall be a minimum of eight (S") inches in diameter and looped when possible. Dead end lines shall not exceed 50 feet on multi-family, commercial, or industrial sites. All public water lines located on private property shall be centered in a 15-foot minimum easement. Larger easements may be required by the Director of Public Works to provide adequate space for maintenance. Water lines shall not be located under paved surfaces where possible. C. Line and Fittinq Materials - All water lines and fittings shall be new materials and comply with the following: 1. Water Lines - All water lines shall be Polyvinyl Chloride (PVC) material and be designed, manufactured, and tested in accordance with the applicable requirements of AWWA C-900 (eight (S") inch through twelve (12") inch water pipe) AWWA C-905 (sixteen (16") inches and larger water pipe), and AWWA M-23. 2. Other Pipe Material - All other materials must be submitted for approval by the Director of Public Works. Ductile Iron pipe is an acceptable substitution. a. All PVC water pipe shall be blue in color. b. Eight (S") inch through twelve (12") inch water pipe shall be pressure class 150, DR 1S. Pressure class 200, DR 14 pipe may be required by the Director of Public Works in areas of high distribution system pressure, under roadways or other unusual circumstances. 3. Fittings - All fittings shall be ductile iron in accordance with AWWA C110 or AWWA C153. Chapter 14 - Engineering Design Standards Page 14 - 15 Colleyville, Texas, Land Development Code a. Fittings: ANSI/AWWA C111/A21.11, except gaskets shall be neoprene or other synthetic rubber and factory installed. Natural rubber will not be acceptable. b. All buried metal shall be wrapped in polyethylene Tube Wrap: ANSI/AWWA C1 05/A21.5. c. All waterline pipe and fittings shall be new materials and produced in the USA. D. Installation - All installations shall conform to the latest NCTCOG, TCEQ and AWWA Specifications, as amended by these standards. 1. All eight (8") inch and ten (10") inch pipe shall be installed with a minimum of forty-eight (48") inches of cover over top of pipe, and pipe twelve (12") inches and larger shall be installed with a minimum of sixty (60") inches of cover over top of pipe. 2. The amount of trench excavation shall not exceed two hundred (200') feet from the end of the pipe laying operations, and no more than three hundred (300') feet of total open trench will be allowed. At the end of each work day, all trench excavation shall be backfilled and compacted to the end of the pipe laying operation. Barricades and lights will be required around any open trench or equipment and cover plates are required in traffic areas. 3. All connections to existing water mains shall be made under pressure unless dry connections will not cause any loss of service. Under special conditions connections that cause an interruption of service may be performed with approval of the Director of Public Works. 4. Coated tracer tape or wire shall be installed in the embedment material twelve (12") inches above the PVC pipe with the tracer wire terminating in in-line gate valve boxes accessible by City Staff. 5. Density tests shall be taken at a minimum of everyone hundred (100') feet for every lift. A maximum thickness of twelve (12") inches per loose lift is required for all trench backfill. The compaction of backfill shall meet or exceed 95% Standard Proctor density. A geotechnical report should be submitted for all trenches. The density reports shall be submitted daily to the City Inspector. The City has the right to require additional tests if they are deemed necessary. 6. All density reports and bacteria test reports shall be completed, delivered to the Director of Public Works and Inspector, and approved before paving is allowed to begin. 7. PVC water pipe and appurtenances shall be installed as specified in AWWA M-23 and in accordance with the pipe manufacturer's recommendations. 8. Fittings shall be installed in accordance with AWWA C-600. a. All mechanical joint bends, tees, and reducers which require blocking shall be additionally restrained with EBAA megalug retainer gland or approved equal. b. All fittings must be polyethylene wrapped. E. Fire Hvdrants 1. Hydrant Location and Spacing - Fire hydrants shall be provided along fire apparatus access roads and adjacent public roads. (0-00-126112/19/00) a. The minimum number of fire hydrants available to a building shall not be less than that listed in Appendix B of the 2000 International Fire Code, as amended. b. The number of fire hydrants available to a complex or subdivision shall not be less than that determined by the spacing requirements in the following table, when applied to fire apparatus access roads and perimeter public streets from which fire operations could be conducted. Chapter 14 - Engineering Design Standards Page 14 -16 Colleyville, Texas, Land Development Code 1 750 or less .m..m...........m. .. ......?..Q9.Q:::.?.!.?.?.9.................. ? ,?9.9.m m m},QQQmm m..~,?9.Q.=.~.!Q9.9...... 4,500 - 5,000 .mm~,~()Q::m . m;m m..t?,Q9.9.m ~,?QQ:::?!QQQ..... .m,m .. 7,500 or more 1 2 3 3 , ,............................ 4 5 6 6 7 ............................................. 8 or more ....".,.....................,............. ..................................... . ...j........... ... 500 450 450 400 350 300 300 250 250 .......................................... . 200 .................~... 250 225 225 .................................... 225 .mm216 ........................................ .............._..........H."............ 180 180 150 150 120 2. Materials - Fire hydrants shall be manufactured in accordance with AWWA C-502, Dry-Barrel Fire Hydrants. Hydrants shall be manufactured such that all maintenance and adjustments can be performed without excavation and such that hydrants may be faced in any direction in relation to base. 3. Installation depth - The standard fire hydrant bury length from ground to bottom of the connecting pipe shall be three (3') feet six (6') inches. The hydrant shall be of a design that will permit extensions without disturbing the bottom section of the hydrant. 4. Gate valve - A gate valve shall be installed with each fire hydrant. 5. Manufacturers - Approved fire hydrants manufacturers are as follows: a. Mueller Centerion A-423 b. Watrous Pacer - 100 c. Clow 6. Locations - Fire hydrants are to be located a minimum of three (3') feet and a maximum of six (6') feet behind the back of curb. F. Valves - Valves of approved design shall be installed at the intersections of all water mains so as to provide for proper maintenance and operation of the system and to provide a means of shutting off the supply to portions of the system for repairs. 1. Valve Spacing - Valves shall be spaced such that only one fire hydrant is out of service at any one time. Three (3) valves shall be used on a four-way water line intersection and a minimum of two (2) valves shall be used on a three-way intersection. 2. Valve Types - Resilient seated gate valves shall be used for six (6") inch through twelve (12") inch water lines. Butterfly valves shall be allowed for twelve (12") inches and larger water lines when approved by the Director of Public Works. 3. Valve Materials a. Resilient Seated Gate Valves (1) Resilient seated gate valves six (6") inches through sixteen (16") inches shall meet or exceed the latest revisions of AWWA C509 and shall meet or exceed the requirements of these standards. (2) Resilient seated gate valves for buried service shall be furnished with a square two (2") inch operating nut. The valve box shall be Tyler Pipe 6850 series or approved equal. The valve box lid shall be painted safety blue. The paint shall be Glidden or approved equal. (3) All valves must open left and close right. Chapter 14 - Engineering Design Standards Page 14 - 17 Colleyville, Texas, Land Development Code b. Butterfly Valves - Butterfly valves shall meet or exceed the latest revision of AWWA Standard C504 for Class 150B butterfly valves and shall meet or exceed the requirements of this specification. All valve components shall conform to Underwriters Laboratories classification in accordance with ANSIINSF Standard 61. 4. Valve Installation a. Valves shall be furnished with extensions, such that the working nut is a maximum of thirty- six (36") inches below grade. b. Adjustable valve boxes shall be furnished and set on each valve in accordance with these standards. Valves that are deeper than forty-eight (4S") inches, AWWA C900 PVC pipe shall be used for stacks, as long as the adjustable valve box is used at the top. c. After the final clean-up and alignment has been complete, the contractor shall cast in place a concrete block, twenty-four (24") inches by twenty-four (24") inches around all valve box tops at the finish grade. See detail W-3. d. Valves located within a right-of-way shall be indicated on the face of the curb, or where curbs do not exist, on a conspicuous location adjacent to the valve location. Markings are to be the stamping of a four (4") inch high letter "V" with a three-eighths (3/S") inch stroke with the point of the "V" pointing towards the valve location. e. Valve markers shall be provided in rural areas. 5. Valve Manufacturers a. Approved manufacturers of six (6") inch through twelve (12") inch resilient seated gate valves are as follows: (1) Mueller, Clow and Waterous b. Approved manufacturers of sixteen (16") inches resilient seated gate valves are as follows: (1) Mueller c. Approved manufacturers of sixteen (16") inch and larger butterfly valves are as follows: (1) Mueller and Clow G. Air Release and Flushinq Valves - Adequate air relief, and flushing valves shall be provided for flushing, disinfecting, daily operation requirements, and repairs when required by the Director of Public Works. Air release valves shall be required on twelve (12") inches and larger water lines. Water lines shall be designed so that each section of the water line can be flushed at its lowest and highest points. 1. All dead end lines shall have a fire hydrant installed for flushing purposes. If installation of a fire hydrant is not possible, a flushing valve is required. 2. A fire hydrant shall be required at high points on water lines smaller than twelve (12") inches for air relief and flushing. 3. Materials - Air release valves and air/vacuum valves shall meet or exceed the latest revision of AWWA C512. H. Tappinq Sleeves - A tapping sleeve and valve shall be used when connecting a new water line to an existing line. A resilient seated gate valve shall be flanged to the tapping sleeve. The tapping sleeve shall be a Smith-Blair Spec. 664-665 stainless steel tapping sleeve, or approved equal. Chapter 14 - Engineering Design Standards Page 14 - 18 Colleyville, Texas, Land Development Code I. Water Services 1. Meter Box Locations - The water meter box shall be placed a minimum of two (2') feet behind the back of curb unless sidewalks are adjacent to the curb, then they are to be set seven (7') feet behind the back of curb, and the water service shall be a minimum of twelve (12") inches deep, covered with a meter box in place at grade. If no curb is present, the water service shall be located at the property line, a minimum of twelve (12") inches deep, covered with a meter box in place at grade. Along roadways without a curb the water service line shall be constructed at a minimum of twelve (12") inches below the ditch flow line. All water services crossing beneath streets may be encased in four (4") inches diameter PVC casing. 2. Meter Size - Meter and service sizes will be determined by the developer prior to requesting service from Colleyville. The minimum water service size between the water main and the meter shall be one (1") inch. Water services on undeveloped lots shall be located at the property line and shall be a minimum of one (1") inch in diameter. 3. Materials a. Service Saddle - Service saddle shall be double strap bronze with brass body or nylon / epoxy coated stainless steel double bolt wide straps. Minimum size tap shall be 1 inch diameter. (1) Approved manufacturers for bronze saddles are Ford, Mueller, Jones or Smith-Blair. (2) Approved manufacturers for nylon stainless steel saddles are Ford, Mueller, JCM or Romac. b. Service Line - Service lines shall be one (1") inch minimum diameter, Type K copper as specified in ASTM B88. c. Corporation Stop - Corporation stop shall be ball type with a diameter equal to the pipe size with compression outlet fitting, designed for a minimum working pressure of two hundred pounds per square inch (200 psi) and threaded counter clockwise. Approved manufacturers are Ford or Mueller. d. Angle Stop - Angle stop shall be set with compression inlet fitting and locking wings. Approved manufacturers are Ford, Mueller or Smith Blair. e. Meter Boxes - Meter box for one (1") inch meters are to be East Jordan Iron Works brand and are to be #37-S Plastic Box with Cast Iron Lid. Meter box for one and one-half (1 %") inch and two (2") inch meters shall be East Jordan Iron Works brand and are to be a 15x27 plastic box with 2 65T dual lids. 4. Installation a. All water services shall be installed in accordance with these standards. b. Each individual service location shall be saw cut into the face of the curb with a four (4") inch high "W" painted blue by the Contractor. If no curb exists a similar mark should be placed in the pavement near the edge of the roadway. 5. Acceptable Manufacturers for Corporation Stops, Curb Stops, and Service Saddles a. Ford b. Mueller c. Smith-Blair J. Flushinq Valves 1. Corporation stop shall be two (2") inch ball type with compression outlet fitting, designed for a minimum working pressure of two hundred pounds per square inch (200"). 2. Two (2") inch curb stop shall be ball type with compression inlet fitting with tee head shut off. Chapter 14 - Engineering Design Standards Page 14 -19 Colleyville, Texas, Land Development Code 3. Pipe shall be two (2") inches diameter, Type K copper as specified in ASTM BSS. 4. All flushing valves shall be installed within a twenty-four (24") inch round metal meter box. K. Water Line Borinqs - Casings shall be required under collectors and thoroughfares, highway crossings, and railroad crossings. Casings may also be required where deemed necessary by the Director of Public Works. Minimum casing thickness shall be a quarter (1/4") inch. The construction bore pit shall be located a minimum distance of four (4') feet behind the back of curb or edge of pavement where no curb is present. 1. Casing Design - The design engineer shall design the water line pipe casing for the following loading conditions and applicable combinations thereof: a. Cooper's E-SO Railway loading or AASHTO HS20 loading as applicable. b. Earth loading with the height of fill above the casing as shown on the plans. c. Loads applied during jacking, including axial load from jacking. d. All other applicable loading conditions, including loads applied during transportation and handling. 2. Casing Materials a. Steel Casing Pipe - Steel casing pipe shall be new (or used if approved by the Director of Public Works) and suitable for the purpose intended and shall have a minimum yield strength of 35,000 psi. Casing shall meet ASTM A-36, ASTM A-570, ASTM A-135, ASTM A-139, or approved equal. Pipe shall be coated with coal tar epoxy (15 mils min.) in accordance with AWWA C-210. Pipe joints shall be welded in accordance with AWWA C-206. After pipe is welded, coating shall be repaired. b. Cement Mortar - Cement mortar shall consist of one (1) part cement to two (2) parts clean sand with sufficient water to make a thick, workable mix. c. Pressure Grout Mix - Grout shall be comprised of one (1) cubic foot of cement and three and a half (3.5) cubic feet of clean fine sand with sufficient water added to provide a free flowing thick slurry. If desired to maintain solids in the mixture in suspension, one cubic foot of commercial grade bentonite may be added to each twelve (12) to fifteen (15) cubic feet of the slurry. d. Casing Insulators (Spacers) - Use casing insulators for any type of carrier pipe. Insulators shall be high density polyethylene. Insulators shall fit snug over the carrier pipe and position the carrier pipe approximately in the center of the casing pipe to provide adequate clearance between the carrier pipe bell and the casing pipe. Insulators shall be manufactured by "Recon" and be Racci Type or approved equal. 3. Casing Installation a. Excavation and Backfill of Access Pits (1) Do not allow excavation over the limits of the bore or tunnel as specified. Trench walls of access pits adjacent to the bore or tunnel face shall be truly vertical. Shore the trench walls as necessary to protect workmen, the public, structures, roadways, and other improvements. (2) Excavations within the right-of-way and not under surfacing shall be backfilled and consolidated by mechanical methods as specified in these standards for compaction of trenches under roadways. Surplus material shall be removed from the right-of-way and the excavation finished to original grades. Backfill pits immediately after the installation of the carrier pipe is completed. If carrier pipe is not installed immediately after casing pipe installation, the City may require the access pits be temporarily backfilled until installation of carrier pipe. (3) Where seeding or sodding is disturbed by excavation or backfilling operations, such areas shall be restored to the existing or better conditions. Chapter 14 - Engineering Design Standards Page 14 - 20 Co/leyvi/le, Texas, Land Development Code Section 14-165 Wastewater System Improvements A. General - This section pertains to general design requirements for wastewater collection system construction in the City of Colleyville. All sewer lines shall be sized and designed in accordance with the City of Colleyville Waste Water System Master Plan or as determined by the Director of Public Works. In the absence of or in conflict with a specific standard contained in this Chapter, all collection, treatment, and disposal systems shall be designed in accordance with the most current criteria adopted by the Texas Administrative Code, Chapter 317, "Design Criteria for Sewerage Systems", NCTCOG, TCEQ and ASTM. B. Sewer Line Sizes and Desiqn 1. Standard sewer line sizes are six (6") inches, eight (S") inches, twelve (12") inches, fifteen (15") inches, and eighteen (1S") inches in diameter. Other sizes may be approved by the Director of Public Works. 2. Sewer lines shall be constructed at a minimum depth of four (4') feet and be located within the parkway or an approved utility easement. A sewer line is required to be constructed on both sides of a State Highway. 3. Easements for sewer line construction shall meet the following requirements: a. The easement width shall be a minimum of fifteen (15') feet. Greater easement width may be required for deep lines. b. If the sewer line is less than twelve (12') feet deep, the outside diameter of the sewer line shall be located a minimum distance of six (6') feet from the edge of the easement, and if other utilities are located in the same easement, the outside diameter of the sewer line shall be located a minimum distance of three (3') feet from the outside diameter of the other utilities. c. If the sewer line is greater than twelve (12') feet deep, the outside diameter of the sewer line shall be located a minimum distance of nine (9') feet from the edge of the easement, and if other utilities are located in the same easement, the outside diameter of the sewer line shall be located a minimum distance of six (6') feet from the outside diameter of the other utilities. d. Proper separation of utilities must be maintained per TCEQ regulations. 4. All sewers shall be designed with consideration for serving the full drainage area subject to collection by the sewer in question; the drainage area may be modified with the concurrence of the Director of Public Works because of the projected rate of development or the financial feasibility of the proposed extension. 5. Sewers should be designed with straight alignment whenever possible. When horizontal curvatures must be used, radial pipe must be used in accordance with the pipe manufacturer's recommendations. No joint deflection is allowed without the approval of the Director of Public Works. 6. All sewers shall be designed with hydraulic slopes sufficient to give mean velocities, when flowing full or half full, of no less than two (2') feet per second. 7. When a one hundred fifty pounds per square inch (150 psi) rated sewer line is required due to its proximity to a water line, the one hundred fifty pounds per square inch (150 psi) rated pipe shall terminate at a manhole on each end. The pipe shall be extended to the interior wall of the manhole. No external boot connection will be allowed. C. Sewer Line Materials - All sewer lines and fittings shall be new materials and comply with the following: 1. All sanitary sewer pipes shall be Polyvinyl Chloride (PVC) pipe type SDR-35 for sewer lines constructed less than fifteen (15') feet deep. SDR-26 shall be provided where sewer lines exceed Chapter 14 - Engineering Design Standards Page 14 - 21 Colleyville, Texas, Land Development Code fifteen (15') feet. PVC pipe will not be allowed for depths greater than twenty four (24') feet unless approved by Director of Public Works. 2. All PVC sanitary sewer pipe shall be green in color. Developer to provide a manufacturers statement for pipe color other than green. 3. PVC sewer pipe and fittings shall conform to the current ASTM Designation D 3034 for four (4") inches through fifteen (15") inches and ASTM Designation F 679 for greater than fifteen (15") inches. D. Sewer Line Installations 1. General a. All installations shall conform to ASTM Designation D2321, and the latest NCTCOG Specifications as amended by these standards. b. Sewer lines shall not be installed within nine (9') feet horizontally of any water main or fire hydrant. Where this is not possible, separation shall be in accordance with TCEQ standards. c. Construction shall begin at the downstream end of project and continue upstream with the bell facing upstream. No upstream piping shall be installed before downstream piping unless approved by the Director of Public Works. 2. Excavation and Backfill a. Filter fabric shall be installed separating the backfill material from the rock embedment no more than twelve (12") inches above the top of the pipe. b. The amount of trench excavation shall not exceed two hundred (200') feet from the end of the pipe laying operations, and no more than three hundred (300') feet of total open trench will be allowed. At the end of each workday, all trench excavation shall be backfilled to the end of the pipe laying operation. Barricades and lights will be required around any open trench left overnight. c. Density tests shall be taken every one hundred (100') feet for every lift. A maximum thickness of twelve (12") inches per loose lift is required for all trench backfill. A geotechnical report should be submitted for all trenches. The compaction of backfill shall meet or exceed 95% Standard Proctor density. The density reports shall be submitted daily to the City Inspector. The City has the right to require additional tests if they are deemed necessary. d. A City inspector will be on site at all times when testing is being performed. The City Inspector shall be present during the placement of trench backfill lifts. e. All density reports shall be completed, delivered to the Director of Public Works and Inspector, and approved before paving is allowed to begin. 3. Inspection and Testing All sanitary sewer lines shall be inspected using standard television inspection methods prior to acceptance by the City. The developer is responsible for television testing. a. The Contractor is responsible for cleaning the sewer pipe. If the inspection shows debris or evidence that the line has not been properly cleaned, the review will cease and the tape will be returned to the Contractor. b. A City representative will be present during the television inspection and all other testing procedures, unless otherwise authorized in writing. c. The televised inspection shall commence only after the line has passed both air and mandrel test. d. The sanitary sewer system must pass all air, mandrel and television tests prior to paving. e. The air and mandrel test must meet the required specifications set forth by the NCTCOG and TCEQ. f. All sanitary sewer mains must be flushed clean with water just prior to televised inspection. All debris must be captured and prevented from blocking the system. Water is to be provided at the Contractor's expense. A City representative is to be present during the flushing of the main. g. All television equipment used shall have a minimum of two hundred twenty (220) lines of horizontal resolution. The picture shall be in color. Chapter 14 - Engineering Design Standards Page 14 - 22 Colleyville, Texas, Land Development Code h. All video information on tape must have good picture quality. i. As a title heading on the tape and during the televising, the operator must note the following: (1) project name and Contractor name. (2) name of the company and the operator performing the video inspection. (3) line size and material, joint type and length. (4) line segment to be televised including beginning and ending station numbers. (5) page of plans used and year plans were stamped. (6) date and time of inspection. (7) A footage counter must be displayed on the tape during the filming. (S) Show the above title block before and after each line segment. Show the title block at one hundred (100') foot intervals while filming the line segment. (9) All defects should be shown on film for a minimum of ten (10) seconds before proceeding with the televising. j. The Contractor shall supply a log sheet used in conjunction with the video tape for written documentation. All written information gathered must be legible and clearly understandable. (1) Note the project name, Contractor name and contract number. (2) Note the name of the company and the operator performing the video inspection. (3) Note pipe size and material, joint type and length between joints. (4) Note the VCR tape footage counter, start to end. (5) Note line segment to be televised, station numbers from and station numbers to length of line segment as indicated on plans. (6) Note page of plans used and year plans were stamped. (7) Note date and time of inspection. (S) Indicate by sketch the line segment to be televised in relation to surrounding road intersections and street addresses. Identify manhole station numbers. Show direction of flow with arrows and direction the camera is going. Indicate direction of north on the sketch. (9) Note the water depth at the beginning, every fifty (50') foot station, every change in grade, and at the end of the line segment. (1 O)ldentify the clock location, direction, size and type of laterals entering main. Indicate laterals as saddles, punched, or glued fittings. (11) Indicate final footage televised at end of the log sheet. k. One tape per visual televised inspection project shall be furnished to the Project Inspector. I. Tapes must be VHS format, one (1") inch wide T-120, high quality tape. Tapes are to be recorded on SP (2 hours) play. m. All tapes and run sheets shall be submitted to the City. All tapes and log sheets shall become the property of the City. 4. Criteria for Repair The Contractor shall make repairs if the inspection reveals any deficiency in the sewer line. If repairs are required, another television inspection shall be made after the repairs are complete on a new tape from manhole to manhole at the Contractor's expense. Any water discovered with a depth of more than one-quarter (1/4") inch will require removal and replacement of the portion of the line not within specification. Repairs shall be made to the satisfaction of the Director of Public Works. E. Manholes 1. Manholes shall be located at all intersections of sewer lines and at intermediate spacing along the line. Generally the maximum spacing should not exceed five hundred (500') feet. Manholes should be located at all changes in grade and at the ends of all sewer lines that will be extended. 2. A manhole is required at the junction of sewer lines with different inside pipe diameters. 3. A drop of at least one tenth of a foot (0.1') is required through the manhole when a change in flow direction occurs. Chapter 14 - Engineering Design Standards Page 14 - 23 Colleyville, Texas, Land Development Code 4. A drop manhole is required when the flow line in is two (2') feet or more greater than the flow line out. 5. Minimum manhole inside diameter is four (4') feet. 6. Drop-connection manholes shall have a minimum inside diameter of four (4') feet, with an exterior drop. 7. Minimum cast-in-place manholes must be installed to the North Central Texas COG standards. 8. Minimum pre-cast wall thickness is five (5") inches. 9. A manhole is required where a sanitary sewer line enters and exits private property. 10. All manholes shall be concrete. 11. Sanitary sewer manhole sizes shall be in accordance with the following table: ................................... ..............,.................... 5' 5' 6' Note: If the proposed design requires the sewer line to be placed at depths greater than shown above, the design will require approval by the Director of Public Works. 12. Cast-in-place Manholes a. The manhole foundation shall be poured on undisturbed soil and shall have a minimum thickness of eight (8") inches. b. The inlet and outlet pipes shall be poured into the foundation of the manhole. When straight through flow occurs, the pipe shall be laid continuously through the manhole. c. The invert shall be shaped and smoothed so that no projections will exist and the invert shall be self cleaning. d. When a cast-in-place manhole is used to connect to an existing sewer line the manhole should be poured, tested and approved before the top of the existing line is cut out. e. Concrete work shall conform to all requirements of ACI 301, Standard Specification for Structural Concrete, published by the American Concrete Institute, except as modified herein. f. Detailing of concrete reinforcement and accessories shall be in accordance with ACI Publication 315. g. Portland cement shall be Type II, low-alkali and conform to ASTM Designation C-150. h. The manhole shall not be backfilled within twelve (12) hours after the concrete placement. Backfill shall be compacted and reports submitted to the City. i. The face of curb shall be stamped with a three (3") inch "MH" to mark the location of all manholes. The location of the stamp shall be a line that intersects the center of the manhole cover and the curb perpendicular to the centerline of the street. For manholes located in intersections, the curb shall be stamped at the closest location to the manhole. If no curb exist a similar mark should be placed in the pavement near the edge of the roadway. 13. Precast Manholes a. Precast manholes shall be constructed in accordance to ASTM Designation C-478. b. Manhole base shall have a spread footing and be placed on a minimum of twelve (12) inches of crushed rock. Chapter 14 - Engineering Design Standards Page 14 - 24 Colleyville, Texas, Land Development Code 14. Manufacturers - Approved precast manhole manufacturers are as follows: a. Hydro-conduit b. Gifford Hill American F. Manhole Frames and Covers 1. Cover a. Materials - All manhole covers shall conform to the Standard Specifications for Domestic Grey Iron Castings, ASTM A-48, Class 30 B. b. Installation (1) All manhole covers shall be twenty four (24") inches in diameter. (2) All manhole covers shall have two (2) integrally cast pick bars. c. Manufacturers (Traffic rated where necessary) (1) Bass and Hays (2) Vulcan 2. Frames a. Materials - All manhole frames shall conform to the Standard Specifications for Grey Iron Castings, ASTM A-48, Class 30 B. b. Installation - All manhole frames shall provide a twenty four (24") inch by one quarter (1/4") inch opening to assure proper fit of the manhole cover. c. Manufacturers (1) Bass and Hays (2) Vulcan d. Manholes located within the floodplain are to be sealed cover and frame. 3. Extension Rings a. Materials - All precast reinforced concrete extension rings shall conform to ASTM C-478. b. Installation (1) The number of extension ring sections shall be kept to a minimum (Le. use 1-12 inch extension ring instead of 2-6 inch extension rings). (2) A one (1") inch by three and a half (3 1/2") inch bitumastic gasket shall be used to seal the extension ring at both joints. 4. Rain Pan a. Materials - Rain pans shall be high density polyethylene plastic. b. Manufacturers - Knutson or approved equal. G. Sewer Services 1. No sewer service line (lateral) shall be less than four (4") inches in nominal diameter. 2. Sewer laterals shall be located at the center of the lot and extended to the property line and be a Chapter 14 - Engineering Design Standards Page 14 - 25 Colleyville, Texas, Land Development Code minimum of ten (10') feet downstream of the water service. Services will be identified in the field by a three (3") inch "S" cut into the curb, on the As-Built Plans and with a stake in the field for location purposes. 3. Sewer service laterals shall have a minimum of four (4') feet of cover at the property line. 4. A c1eanout shall be located on the service lateral at the time of connection to the home. 5. Materials a. All lateral sewer service lines shall be gasketed PVC pipe type SDR-35. b. All PVC sanitary sewer pipe used for lateral services shall be green in color. (ASTM SPEC) 6. Installation - All service laterals shall be installed in accordance with the sanitary sewer embedment and backfill standards of the City of Colleyville. 7. Video Inspection Required - All sewer service lines that are connected to a section of sewer service piping located within the right-of-way must have a clean-out installed where the property line abuts the right-of-way. After the new sewer service line has been connected and the excavated area is backfilled, the portion of the sewer service line located within the right-of-way including the tap into the sewer main must be televised. The video tape must be submitted to and approved by the City of Colleyville Public Works Department. 8. Point of Connection - The point of connection for all sanitary sewer service lines shall be made to an approved public sewer main line. No sanitary sewer service line shall directly connect to a manhole. H. Main Line Cleanouts - Cleanouts may be installed on lines that are permanent dead ends. The line may not exceed two hundred fifty (250') feet. Any line exceeding that length must end with a manhole. I. Sewer Line Borinqs 1. The design engineer shall design the sewer line pipe casing for the following loading conditions and applicable combinations thereof. a. Cooper's E-80 Railway loading or AASHTO HS20 loading as applicable. b. Earth loading with the height of fill above the casing as shown on the plans. c. Loads applied during jacking, including axial load from jacking. d. All other applicable loading conditions, including loads applied during transportation and handling. 2. Materials - Materials must meet jurisdictional requirements in all areas, Railroad, TCEQ, TXDOT, etc. a. Steel Casing Pipe - Steel casing pipe shall be new (or used if approved by the Director of Public Works) and suitable for the purpose intended and shall have a minimum yield strength of 35,000 psi. Casing shall meet ASTM A-36, ASTM A-570, ASTM A-135, ASTM A-139, or approved equal. Pipe shall be coated with coal tar epoxy (15 mils min.) in accordance with AWWA C-210. Pipe joints shall be welded in accordance with AWWA C-206. After pipe is welded, coating shall be repaired. b. Cement Mortar - Cement mortar shall consist of one (1) part cement to two (2) parts clean sand with sufficient water to make a thick, workable mix. c. Pressure Grout Mix - Grout shall be comprised of one (1) cubic foot of cement and three and a half (3.5) cubic feet of clean fine sand with sufficient water added to provide a free flowing thick slurry. If desired to maintain solids in the mixture in suspension, one (1) cubic foot of commercial grade bentonite may be added to each twelve (12) to fifteen (15) cubic feet of the slurry. d. Casing Insulators (Spacers) - Use casing insulators for any type of carrier pipe. Insulators shall be high density polyethylene. Insulators shall fit snug over the carrier pipe and position the carrier pipe approximately in the center of the casing pipe to provide adequate clearance between Chapter 14 - Engineering Design Standards Page 14 - 26 Colleyville, Texas, Land Development Code the carrier pipe bell and the casing pipe. Insulators shall be manufactured by "Recon" and be Racci Type or approved equal. 3. Installation a. Tolerances (1) All bores shall be installed at a grade no less that the minimum indicated by TAC, Chapter 317 for the desired pipe size. (2) All bores shall maintain grade enough to ensure desired clearance distances between existing utilities and bore. b. Excavation and Backfill of Access Pits (1) Bore pits must be a minimum of four (4') feet from the back of curb when located for boring under roadways. (2) Do not allow excavation over the limits of the bore or tunnel as specified. Trench walls of access pits adjacent to the bore or tunnel face shall be truly vertical. Shore the trench walls as necessary to protect workmen, the public, structures, roadways, and other improvements. (3) Excavations within the right-of-way and not under surfacing shall be backfilled and consolidated by mechanical methods as specified in these standards for compaction of trenches under roadways. Surplus material shall be removed from the right-of-way and the excavation finished to original grades. Backfill pits immediately after the installation of the carrier pipe is completed. If carrier pipe is not installed immediately after casing pipe installation, the right-of-way Owner may require the access pits be temporarily backfilled until installation of carrier pipe. Plug ends of sleeves to prevent soil migration. (4) Where seeding or sodding is disturbed by excavation or backfilling operations, such areas shall be replaced to meet existing or better conditions. Section 14-170 Drainage and Storm Sewer Improvements A. General - This section pertains to general design requirements for drainage and storm sewer construction in the City of Colleyville. All drainage facilities shall be sized and designed in accordance with the City of Colleyville Drainage Master Plan or as determined by the Director of Public Works. B. Runoff Calculations - The selection of which method to use for calculating runoff depends upon the size of the contributing drainage area at the most downstream point of the project. The "Rational Method" is acceptable for designing projects in which the drainage area is less than one-hundred (100) acres. A unit hydrograph method is required for projects with larger drainage areas. 1. No matter which method is used to calculate runoff, a developer or builder of residential property greater than one (1) acre in size, or any property that was platted as a part of an overall tract which was greater than one (1) acre in size (including churches and schools), shall develop the property so that the rate of runoff created by the development as it leaves the property does not exceed the rate of runoff that is currently occurring in the existing conditions. A developer or builder of commercial property greater than one-half (1/2) acre must follow the above guidelines. 2. Runoff computations shall be based upon fully developed watershed conditions in accordance with the land use projections in the latest comprehensive land use plan for the City of Colleyville. The design engineer shall size drainage facilities by disregarding the detention effects of upstream property and calculating the runoff as if the off-site property was developed without any detention. If an approved regional detention/retention facility is in operation, the design engineer may size downstream drainage facilities based on consideration of the detention effects of the regional facility. C. Drainaoe Areas Less Than one-hundred acres 1. Computation of Storm water Runoff for drainage areas less than one-hundred (100) acres shall be by the "Rational Method," which is based on the principle that the maximum rate of runoff from a given Chapter 14 - Engineering Design Standards Page 14 - 27 Colleyville, Texas, Land Development Code drainage area for an assumed rainfall intensity occurs when all parts of the area are contributing to the flow at the point of discharge. ...... ...P~.~.~...~.~~~.!:l...~....1'l9...~.~\I.~I()p~~...I~.~.~...... [?~\I~I()PEl<lP~r.~!:litEl!:lmmmmmm..... m . .~!1.l9IElI"~'!liIYf3E!!:li<lE!I.l!i~lm ... . [?l,lpIEl)(m... ... ...........Ml,lI!ipl~.~.C1'!li.l.y....... Schools .................................... . Churches ......................................................................................................................... . .mNE!i9~b.gr~()l?<l~<:l'!l'!lEl~~.i!3.lm Office Commercial ................................................................... Commercial ................................................. . Industrial 0.60 0.70 0.70 0.70 0.70 0.70 0.85 2. Time of concentration is the longest time, without interruption of flow by detention devices that a drop of water takes to flow from the farthest point of the drainage area to the point of concentration (i.e. the point of design). The time of concentration is composed of the inlet time and the flow time in a conduit or channel to the point of design. The inlet time shall be 10 minutes for property zoned multiple family, churches, schools, local business, central business, commercial, or industrial. An inlet time of 15 minutes shall be used for property zoned for parks, cemeteries, agricultural, and single family residential. When designing inlets and laterals, the time of concentration is equal to the inlet time. The design engineer will compare the above specified inlet times to the actual calculated inlet time by computing the flow time overland and along the gutter to the first inlet. Manning's Equation shall be used to determine flow time to the inlet. The design engineer may use the actual calculated or specified inlet time. In no case shall a longer inlet time be used than 10 minutes for multiple family, commercial, churches, schools, industrial and business areas and 15 minutes for parks, cemeteries, agricultural, and single-family areas. D. Drainaqe Areas of one-hundred (100) acres or More 1. For drainage areas of one-hundred (100) acres or more where the use of the "Rational Method" does not provide reliable results, the use of a unit hydrograph method shall be made. The use of a unit hydrograph calculation will be based upon standard and accepted engineering principles subject to the approval of the Director of Public Works. Acceptable methods include the Soil Conservation Service (SCS) Technical Release Number 55 or the Corps of Engineers HEC-1 models for drainage areas one-hundred (100) acres or more. 2. The unit hydrograph method shall be based upon fully developed watershed conditions assuming no effects from the small on-site detention facilities for maintaining the rate of runoff as if the property was undeveloped. The detention effects of large regional detention facilities can be taken into account in unit hydrograph methods. 3. Circumstances that may require the use of a unit hydrograph method include sizing open channels, reclaiming floodplains, creating lakes, or building other types of drainage-related facilities on major drainage courses. Design engineers of these types of facilities should be aware that the requirement of designing for fully developed watershed conditions will mean that they will have to calculate these Chapter 14 - Engineering Design Standards Page 14 - 28 Colleyville, Texas, Land Development Code fully developed flows instead of using the flows calculated in the Federal Emergency Management Agency's (FEMA) flood insurance studies for Colleyville or Tarrant County or from studies performed for or approved by the City of Colleyville. E. Desiqn Storm Frequencies - All developments submitted must provide data for the following design storm frequencies: 2-Year /5-Year /10-Year /25-Year /50-Year /100-Year. 1. Drainage facilities shall be designed in accordance with the following table: Closed Storm Sewer Systems ! 5-year with 1 DO-year positive overflow in streets i such that the depth of flow in the street does not , exceed the right-of-way or drainage easement ....Cios.edSlormSewerSystems \....{m~~2~iwith.positFveoveffiov:;m and Inlets at Street Low Point : g~_~_~9m.__.mm__m _.gl!ly~r,t~.'l.Il<:l...!=l..r..i.<:l9.~~.............. Concrete-lined Channels .................................H.H.H.......H.H......................... Earthen Channels 2. The approved drainage system shall provide for positive overflow at all low points and these areas must be denoted on the plans as such. The term "positive overflow" means that when the inlets do not function properly or when the design capacity of the conduit is exceeded, the excess flow can be conveyed overland along a grassed or paved course. Normally, this would mean along a street or alley, or shall require the dedications of special drainage easements on private property. F. Street and Alley Capacity 1. Streets - Streets and storm drains within new developments shall be designed so that storm water runoff resulting from a design storm of a one-hundred (100) year frequency is contained within the available right-of-way and/or drainage easement. The capacity of the street and right-of-way and/or easement and the storm sewer pipe working in combination must be designed for a capacity to safely contain a storm water from a design storm of one-hundred (100) year frequency. 2. Alleys - The flows created by the one-hundred (100) year storm shall be contained within the capacity of all paved alleys. G. Inlet Placement and Capacity - The storm sewer system is to begin at the point where the storm water from a five (5) year frequency storm reaches curb depth, with the exception of collector streets on which storm sewer facilities must be designed to prevent one-twelve (12') foot wide lane from ponding and on major streets on which storm sewer facilities must be designed to prevent one-twelve (12') foot wide lane in each direction from ponding. At such point where the combined capacity of the street and storm drain system satisfies the five (5) year street capacity criteria (as previously described) but the one-hundred (100) year frequency storm runoff can not be contained within the right-of-way additional pick-up points (inlet capacity) shall be provided along with an increase in storm sewer capacity so that the one-hundred (100) year frequency storm runoff will be contained within the right-of-way. 1. Inlets shall be placed upstream from an intersection whenever possible. At any intersection, only one street shall be crossed with surface drainage and this street shall be the lower classified street. When an alley intersects a street, inlets shall be placed in the alley whenever flow down that alley would cause the capacity of the intersecting street to be exceeded. 2. The minimum inlet size shall be ten (10') feet. No more than twenty (20') feet of inlet shall be placed along one gutter at any given location. Minimum sizes of laterals shall be twenty-one (21") inches for use with ten (10') foot inlets, and twenty-four (24") inch laterals with fourteen (14') foot, twenty (20') foot inlets, and drop inlets. Where laterals tie into trunk lines, place the laterals on a minimum angle forty-five (450) degrees and a maximum angle of sixty (600) degrees with the trunk line and connect them so that the longitudinal centers intersect. Chapter 14 - Engineering Design Standards Page 14 - 29 Colleyville, Texas, Land Development Code 3. Manholes are required every three hundred feet (300'). Junction boxes are required at every change in flow line direction, change in pipe size, and where a convergence of more than two pipes occurs. Manholes are to be five feet (5') square and can be precast or cast in place. H. Pipe Desiqn Standards 1. Storm sewer conduit shall be sized to flow full. Manning's Equation shall be used to determine the conduit size. 2. Design Velocities a. Minimum - two and a half feet (2.5') per second. b. Maximum - twelve feet (12') per second. c. The maximum discharge velocities in the pipe shall also not exceed the permitted velocity of the receiving channel or conduit at the outfall to prevent erosive conditions. The maximum outfall velocity of a conduit in partial flow shall be computed for partial depth and shall not exceed the maximum permissible velocity of the receiving channel unless controlled by an appropriate energy dissipater (e.g. stilling basins, impact basins, riprap protection). 3. In general, storm water shall be carried in concrete pipe conduit within the right-of-way but other types of conduit can be used to carry stormwater in areas other than the right-of-way. However, prior permission to use other conduit materials must be obtained from the Director of Public Works. 4. Hydraulic Gradient (also refer to the Ft. Worth Drainage Manual) a. Conduits must be sized, and slopes must be set, such that runoff flows smoothly down the drainage system. To insure this smooth passage, the hydraulic gradient must be at the proper elevations. The hydraulic grade line shall be established and shown on the plans for all storm sewer design. b. The hydraulic grade line shall in no case be closer to the surface of the ground or street than one foot (1'). The HGL must not exceed the neck into the inlet. c. Hydraulic gradient calculations shall account for all head losses that may occur in the storm sewer line. Friction head loss shall be determined by direct application of Manning's Equation. Minor losses due to turbulence at structures shall be determined using Appendix A of this section. 5. Inspection / Testing a. The compaction of backfill shall meet or exceed 95% Standard Proctor density. b. All storm sewer conduits shall be inspected prior to acceptance by the City. All conduit forty-two inch (42") or less shall be inspected using television inspection. Conduits larger than forty-two inch (42") may be inspected visually. c. A City representative shall be present during the television inspection. d. Televised Inspection Criteria (1) All television equipment used shall have a minimum of two-hundred-twenty (220) lines of horizontal resolution. The picture shall be in color. (2) All video information on tape must have good picture quality. (3) As a title heading on the tape and during the televising, the operator must: i. Note the project name and Contractor name. ii. Note the name of the company and the operator performing the video inspection. iii. Note line size and material, joint type and length. Chapter 14 - Engineering Design Standards Page 14 - 30 ColleyvWe, Texas, Land Development Code iv. Line segment to be televised including beginning and ending station numbers. v. Note page of plans used and year plans were stamped. vi. Note date and time of inspection. vii. A footage counter must be displayed on the tape during the filming. viii. Show the above title block before and after each line segment. Show the title block at one-hundred (100') foot intervals while filming the line segment. ix. All defects should be shown on film for a minimum of 10 seconds before proceeding with the televising. (4) The Contractor shall supply a log sheet used in conjunction with the video tape for written documentation. All written information gathered must be legible and clearly understandable. i. Note the project name, Contractor name and contract number. ii. Note the name of the company and the operator performing the video inspection. iii. Note pipe size and material, joint type and length between joints. iv. Note the VCR tape footage counter, start to end. v. Note line segment to be televised, station numbers from and station numbers to length of line segment as indicated on plans. vi. Note page of plans used and year plans were stamped. vii. Note date and time of inspection. viii. Indicate by sketch the line segment to be televised in relation to surrounding road intersections and street addresses. Identify manhole station numbers. Show direction of flow with arrows and direction the camera is going. Indicate direction of north on the sketch. ix. Note the water depth at the beginning, every fifty (50') foot station, every change in grade, and at the end of the line segment. x. Identify the clock location, direction, size and type of laterals entering main. Indicate laterals as saddles, punched, or glued fittings. xi. Indicate final footage televised at end of the log sheet. (5) One tape per visual televised inspection project shall be furnished to the Project Inspector. (6) Tapes must be VHS format, one (1") inch wide T-120, high quality tape. Tapes are to be recorded on SP (2 hours) play. (7) All tapes and run sheets shall be submitted to the City. All tapes and log sheets shall become the property of the City. I. Culvert Desiqn - Culverts must be designed using standard engineering practices and engineering judgment. Culverts shall be designed in accordance with the latest edition of the City of Fort Worth Drainage Manual. If the City of Fort Worth Drainage Manual does not incorporate the necessary standards please refer to the Texas Department of Transportation (TxDOT) Hydraulic Design Manual. 1. One (1') foot of freeboard is required between the one-hundred (100) year water surface elevation and the top of curb elevation. Exceptions must be approved in writing by the Director of Public Works. 2. Culvert hydraulic grade line calculations shall consider both inlet and outlet control. 3. Culverts shall be aligned to provide the minimum resistance to the flow of water during the 10, 50, 100 and 500 year events. 4. The maximum velocity through a culvert shall be fifteen (15') feet per second. 5. Stream stability shall be assessed when determining the number of barrels, height and width and culvert skew. Potential for scour shall be accounted for in the design. 6. Hydraulic jumps shall not be allowed from face of culvert to ten (10') feet from the culvert, subject to the approval of the Director of Public Works. Chapter 14 - Engineering Design Standards Page 14 - 31 Colleyville, Texas, Land Development Code J. BridQes - Two (2') feet of freeboard is required between the one-hundred (100) year water surface elevation and the low chord of the bridge. Exceptions to this requirement must be approved by the Director of Public Works in writing. 1. The skew of the bridge piers and abutments shall be oriented as close to the normal or flood direction of flow resulting in an angle of attack as close to zero (0) degrees as possible. 2. Bridge piers shall be aligned to provide the minimum resistance to the flow of water during the 10, 50, 100 and 500 year events. 3. Computer modeling programs used for the hydraulic analysis of bridges shall be HEC-RAS, Version 2.2, or HEC2. 4. Stream stability shall be assessed when designing the abutments and interior bents of the bridge. Scour shall be accounted for in the design. 5. Where flows are supercritical, erosion control measures shall be used in an area from one-hundred (100') feet upstream from a bridge to twenty-five (25') feet downstream from a bridge. K. Channels - Open channels may be used instead of an enclosed system when a pipe greater than an eighty-four (84") inch diameter (or other shape equivalent to more than thirty-eight and a half (38.5) square feet) is required to carry the design storm event. 1. Design Criteria: a. All open channel design must follow the Corp of Engineers Guidelines. b. Channels may be left in their natural state provided that the channel velocities are six (6.0') feet per second or less and that one (1') foot of freeboard is available during the design storm event. c. If the natural channel is to be replaced by an improved channel, the flow from the one-hundred (100') year design flood must be contained within the improved channel while allowing for one (1') foot of freeboard. d. Improved channels shall be trapezoidal shaped and include a lined section if the design velocity is greater than six feet per second. Lining types such as concrete, rock walls and gabions may be used upon approval of the Director of Public Works. The maximum velocity allowed in concrete lined channels is fifteen (15') feet per second. e. Unless shown to be feasible in a soils report sealed by a licensed professional engineer in the State of Texas, and approved by the Director of Public Works, improved channels shall have minimum side slopes of: (1) 4 feet horizontal to 1 foot vertical for earthen, grassed-lined side slopes. (2) 2 feet horizontal to 1 foot vertical for concrete-lined side slopes. f. Where practicable, all unpaved channels should have sufficient grade to avoid ponding. A minimum slope of 1.00% is required for earthen channels and swales, except those used as part of a wetlands area. In areas where 1.00% cannot be obtained a pilot channel approved by the City may be used. All lined channels are to have a minimum slope of 0.50% and earthen channels a minimum slope of 1.00%. g. The developer or owner shall use low maintenance vegetation for vegetative cover, as approved by the Director of Public Works prior to planting. The selection of materials shall comply with the current ground cover listing for North Central Texas furnished through the Texas Agricultural Extension Service. 2. Manning's Equation can be used to design channels and determine water surface elevations and Chapter 14 - Engineering Design Standards Page 14 - 32 Colleyville, Texas, Land Development Code velocities when backwater effects are negligible, subject to approval by the Director of Public Works. Channels where backwater effects occur must be designed using models accepted by FEMA. 3. All channel sections must consider and account for channel stabilization in their design. This requirement pertains to all sections whether they are left in their natural condition or are modified in any manner. The design of all drainage channels and swales shall assure adequate capacity and minimum maintenance to overcome the result of erosion, silting, sloughing of bends or similar occurrences. 4. When performing hydraulic analyses for channel or drainageway design, the one-hundred year (100) year starting water surface shall be based on the following: a. Known water surface elevations should be used where possible. Known elevations are available for some creeks and channels from previous studies approved by the City. b. When known water surface elevations are not available the slope-area method or a rating curve may be used. (1) A rating curve approximates the starting water surface elevation for a given flow by using the relationship between known flows and water surface elevations for the creek. This is an excellent method for determining starting conditions if good data is available to develop the rating curve. (2) The slope-area method approximates the starting water surface elevation by calculating the normal depth for the channel. To calculate normal depth the slope of energy gradient for the channel is required. The energy slope can be approximated using the average slope of the channel or the average slope of the water surface. 5. The design of the channel lining shall take into account the super-elevation of the water surface around curves and other changes in direction. In general a radius that is three (3) times the top width of the water surface during the design storm event is recommended for channel bends. 6. A chain link fence six (6') feet in height, or other improvements as approved on a case by case basis by the Director of Public Works, shall be constructed on each side of the lined channel. 7. Gabion or other forms of channel lining may be used in lieu of reinforced concrete lining with the approval of the Director of Public Works. L. Detention Desiqn - Runoff rates for all land uses shall be limited to the rates that would be produced from single family residential areas. This requirement also applies to the development of sites as churches, schools, and other institutional uses. Detention/retention facilities shall be designed for the fully developed one-hundred (100) year design flood according to the following criteria: 1. The minimum amount of storage volume of the detention basin shall be that volume required to reduce runoff rate during the one-hundred (100) year event to the undeveloped rate. The outflow structure shall be sized to reduce the 2, 5, 10, 25, 50, and 100 year discharges to the undeveloped rate. Dedicated detention/retention basins shall also include an additional one (1) foot of freeboard and two (2) feet of sediment storage. The volume of runoff storage for drainage areas greater than one-hundred (100) acres shall be computed using unit hydrograph procedures. Acceptable unit hydrograph procedures are provided in Section 14-170.D.1 of this document. For drainage areas less than one-hundred (100) acres, the above methods are recommended; however, an approximate routing method based on the modified rational method is allowable. 2. All detention facilities designed shall consider the timing of the flood peak in the main channel into which the detention facility drains. Delaying the peak from a site in lower portions of a watershed may result in a higher peak on the main channel. The Director of Public Works may require that upstream and downstream ponds be included in the detention design model. 3. A detention facility shall have enough gradient to ensure positive drainage to the outlet structures so Chapter 14 - Engineering Design Standards Page 14 - 33 Colleyville, Texas, Land Development Code as to avoid nuisance conditions such as standing water, odors, insects, and weeds. A minimum slope of 0.50% towards the outlet structure is required for all grass lined detention facilities. 4. Detention areas in parking lots shall not be: a. In required parking spaces. b. Behind speed bumps unless the speed bumps are made with reinforced concrete. c. Deeper than six (6") inches unless otherwise approved by the Director of Public Works. 5. Drainage easements shall be provided for all regional detention/retention facilities and for other detention/retention facilities where two or more owners are involved. 6. Individual detention facilities shall be designed to empty in less than three (3) hours, unless it is also serving as an erosion control facility. 7. Detention facilities used as a sediment control facility shall meet the following requirements: a. The sediment control facility shall be designed with minimal velocities such that sediment is dropped and not picked up by flows at any time during the storm event. b. The basin shall be designed with two (2) feet of sediment storage area so that sediment removal is not required more than twice a year. Expected removal periods greater than twice a year must be specified in the maintenance plan and approved by the Director of Public Works. c. Sediment control facilities cannot be used to meet detention requirements unless the volume of sediment is included in the calculations for the detention basin design. 8. The owner shall maintain detention/retention facilities unless the facilities are dedicated to the City of Colleyville. Detention facilities must be properly maintained if they are to function as intended over a long period of time. The following measures are required to ensure the facility functions properly. a. Facilities should be mowed at least twice a year to control weeds and discourage woody growth. b. Debris, litter and accumulated sediment should be removed from detention facilities at least twice a year. Particular attention should be given to removal of debris, litter and sediment around outlet structures. The Director of Public Works may require that the property owner remove said debris when in the Director's determination that property damage or a flood hazard may exist. c. Detention basins designed for sediment removal shall be maintained as specified in the maintenance plan and approved by the City with construction plan submittal. M. Flumes - The use of flumes is not recommended for widespread use. Flumes shall not be permitted when the purpose of a permanent flume is to carry runoff down the sides of earthen channels. 1. A flume may be used to direct overflow runoff along property lines until the runoff can be intercepted by streets or conduits. A flume shall not carry more than ten (10) cubic feet per second during the one-hundred (100) year storm event with a slope of 1.00%. 2. All flumes crossing sidewalks shall be covered or bridged such as to minimize danger to pedestrians. 3. All edges are to be protected with rock rip-rap or other form of protection for erosion control and scour purposes. N. Lakes - Approval to develop in any area subject to inundation by a lake must be obtained from the appropriate agency responsible for that particular lake before the city grants its approval. Agencies that should be contacted include U.S. Army Corps of Engineers, Tarrant County Water Control Board, TCEQ, the Trinity River Authority, and FEMA. Regardless of approvals obtained from those agencies listed above, no filling, development or Chapter 14 - Engineering Design Standards Page 14 - 34 Co/leyville, Texas, Land Development Code construction in any area subject to inundation by a lake shall occur without the approval of the City Manager. The City Manager may require any studies necessary to determine that filling, development or construction will not have a detrimental effect on adjacent, upstream or downstream properties and buildings. This subsection in no way diminishes other requirements of this section. O. Lot Drainaoe and Gradinq - Grading and drainage of all residential lots shall be designed in a manner which will allow one lot to drain across an adjacent lot and into a permanent structure, such as a concrete flume, lined channel, or proper inlet to an adequate drainage facility, or to a street right-of-way. If an approved drainage structure is not present, it will be required of the developer to construct the necessary facilities. (0-00-1261/12/19/00) 1. Sheet flow techniques shall be used for lot to lot drainage where possible. (0-00-1261/12/19/00) 2. Single lots shall accommodate their own drainage into an approved structure where topographic elevations allow this to occur. (0-00-1261112/19/00) Section 14-175 Miscellaneous A. Trench Safety - In conformance with House Bills 662 and 665 as passed by the Seventieth Legislature Regular Session of the State of Texas, all construction projects within the City of Colleyville or its extraterritorial jurisdiction as provided by the Municipal Annexation Act (Article 970a, Vernon's Texas Civil Statutes) shall contain provisions for trench safety. On construction projects in which trench excavation will exceed a depth of five (5) feet, the uniform set of general conditions must require that the bid documents and the contract include detailed plans and specifications for adequate safety systems that meet Occupational Safety and Health Administration standards and that these plans and specifications include a pay item for these same safety systems. B. Underoround Utilities - All distribution lines, cables, etc. for utilities other than those listed above shall be installed below ground within the subdivision. Transmission lines or major cables to provide utilities such as electric, telephone, and cable television to the area as a whole may be located above ground on the perimeter of the subdivision being served. The installation of these utilities shall conform to commonly accepted construction standards and be subject to review by the Director of Public Works. Section 14-180 Drainage Studies and Engineering Certification A. Preliminary Drainaoe Analysis Guidelines - The purpose of a Preliminary Drainage Analysis is to determine the need for drainage facilities and/or drainage easements either within the proposed development or offsite. A Preliminary Drainage Analysis is required for every subdivision plat or a development requesting a building permit on a parcel which does not have a previously approved drainage analysis, unless the Director of Public Works has waived this requirement due to existing conditions. The Preliminary Drainage Analysis shall consist of the following information: 1. A topographical map drawn at a scale of I" = 200' which depicts the watershed that drains to and across the subdivision or development. The map must include the subdivision and an area extending a minimum of 200' in all directions from the proposed subdivision. Sheets shall be either 18" X 24" or 24" X 36" in size and may contain sheet to sheet match lines. The map must include contour lines at five (5') foot vertical intervals in terrain with a slope of two (2%) percent or more, or two (2') foot vertical intervals in terrain with a slope of less than two (2%) percent. Data from the City topographic maps will be acceptable where available. Data from USGS Quad sheets may be acceptable only where City topographic maps are not available. The datum for "0" topography shall be that of the United States Coast and Geodetic Surveyor the City of Colleyville GIS datum. The map shall indicate any offsite or adjoining areas outside the limits of the area being developed which are relevant to onsite drainage. Show all significant physical features such as proposed or existing drainage and utility easements, water bodies, streams, railroads, parks, and drainage ditches. Show location of existing utilities including gas and petroleum lines, electric, telephone and Chapter 14 - Engineering Design Standards Page 14 - 35 Colleyville, Texas, Land Development Code TV cable. Also, the location of any existing structures located within the area being proposed for development. The plan shall include the building footprint and parking areas when the Preliminary Drainage Analysis is prepared for a building permit. 2. Calculation of the drainage areas, time of concentration, and storm water runoff rate for the 2, 5, 10, 25, 50 and 100-year frequency storms. The design calculations shall include preliminary locations of drainage facilities. (0-00-1261/12/19/00) 3. Identification of special flood hazard areas as defined by the Flood Hazard Area Regulations Ordinance and as located by the current Flood Insurance Rate Map. 4. The Preliminary Drainage Analysis shall be sealed by a Registered professional Engineer licensed by the State of Texas. B. Drainaqe Study Guidelines - A Drainage Study is required when it has been determined by the Director of Public Works that the area being developed will require storm water drainage facilities or drainage easements either within the development or offsite. The following criteria shall be used for the developer's engineer to prepare a Drainage Study. 1. The study shall analyze the effect of the subdivision or the development on existing downstream drainage facilities. The study shall be sufficient to verify compliance with the drainage design criteria contained in this chapter. 2. The study shall include a topographical map as defined above in "Preliminary Drainage Analysis Guidelines." 3. Delineation and calculation of drainage areas together with proposed flow arrows shall represent flow patterns from runoff after all proposed improvements have been installed. Surface water drainage patterns shall be shown for each and every lot in the proposed subdivision and for each lot adjacent to the proposed subdivision. 4. In addition to those calculations required by the Preliminary Drainage Analysis, this study shall also include: a. Hydraulic calculations to each lateral, manhole, inlet and outlet structure on the pipe. Head losses shall be calculated as described elsewhere in this chapter. b. Inlet calculations utilizing the minimum time of concentration for the zoning type which is contributing the largest "CA" to the inlet. 5. If any portion of the proposed subdivision or its offsite improvements (including pipes or ditches) falls within the limits of a Federal Emergency Management Agency (FEMA) floodplain, additional backwater calculations may be required. Additional calculations in the form of a Conditional Letter of Map Revision will be required if: a. Any portion of the proposed subdivision is determined to be located within a FEMA Zone "A" floodplain; or b. Any portion of the proposed subdivision is determined to be located within a FEMA Zone "AE" floodplain and the overall subdivision (including all phases) is 5 acres or larger; or c. Any portion of the proposed improvements from a subdivision include dredging or filling within a FEMA designated floodway. 6. Backwater calculations shall comply with normally accepted standards as required by FEMA for application for a Letter of Map Revision (LOMR). In addition, the calculations must begin with a previously defined Base Flood Elevation (BFE). The calculations shall continue upstream through the project until the proposed BFE is within .01 feet of the existing BFE or the limits of the existing Zone 'A' have been reached. A LOMR will be required prior to issuing building permits. Chapter 14 - Engineering Design Standards Page 14 - 36 Colleyville, Texas, Land Development Code C. Certification - All drainage studies and/or plans including those which are part of a standard construction plan submittal shall be sealed and signed by an engineer proficient in civil engineering and registered in the State of Texas. All drainage submittals shall include the following certifying statement by the "Engineer of Record". I a Professional Engineer licensed in the State of Texas have prepared this drainage study and/or plan in compliance with the latest published requirements and criteria of the City of Colleyville, and have verified that the topographic information used in this study and/or plan is in compliance with said requirements and is otherwise suitable for developing this workable plan of drainage which can be implemented through proper subsequent detailed construction planning. Signature D. Disclaimer of Liabilitv - The degree of flood protection required by this policy is considered reasonable for regulatory purposes and is based on scientific and engineering considerations. On rare occasions greater floods can and will occur and flood heights may be increased by man-made or natural causes. This policy does not imply that land outside the areas of street rights-of-way, drainage or flood plain easements will be free from flooding or flood damages. This policy shall not create liability on the part of the City of Colleyville, Texas or any official or employee thereof for any flood damages that result from reliance on this policy or any administrative decision lawfully made thereunder. Section 14-185 Amendments to This Chapter Reserved for listing of amendments to this Chapter. Ord. Number 0-00-1261 Date 12/19/00 0-01-1280 0-03-1403 01/08/01 05/06/03 Chapter 14 - Engineering Design Standards Page 14 - 37 CITY COUNCIL cc6@ 7" L~:X" So AGENDA BRIEFING MEETING DATE: ITEM # : ORDINANCE #: 05/06/03 9 0-03-1404 CITY MANAGER I DEPARTMENT HEAD! ~~ FINANCE REVIEW! N/A Previous Action: N/A DEPARTMENT: FINANCE SUBJECT : Approval to amend Ordinance 0-92-880 establishing the fee structure for the circulation of materials and replacement and processing fees for materials for the Colleyville Public Library First Reading and Public Hearing As per the attached memorandum, the Colleyville Library Board recently approved the Circulation Policies for the Colleyville Public Library including the fee structure for the books and materials collection and the replacement and processing fees. (See attached). The proposed fees are comparable to other area public libraries. Upon approval, staff will work with The Library Corporation (TLC) to assist in programming the fee structure into the integrated library system. Financial Impact The fees will be included as a source of revenue in the proposed FY 2003 -2004 budget. Recommendation Approval Attachments . Area Public Library Research and Analysis . Colleyville Public Library - Staff Memorandum . Ordinance 0-03-1404 :E enW ..JI- <(-en -o::W o::W- Wa..o:: 1--<( <(>-0:: :E<(m c- Wo::..J ::JW<( ca..W 0:: 0:: Wen<( >W QZ u. W 0::: :::l I- W <C 0 0 ~ 0 0 0 0 0 w C! N .... N C! C! C! u. ci u. ci ci .... .... .... .... I/) w w 0 w w w w w 0 Z > 0 z 0 i= () w u. 0 0 z 0 0 0 0 0 z C! N u: .... ~ C! C! C! 0 .... ci 0 0 .... .... .... z w w 0 w w w w w I/) Z 0 > 0 UJ () 5Q w 0 I- 0 0 z 0 0 0 It) 0 ..-; ~ u. .... N .... N C! () 0 0 ci ci ci ci .... <C w w 0 w w w w w Il. Z :! 0 () UJ W ~ 0 0 ~ 0 0 0 It) It) .... ~ .... ~ .... ~ ~ 0 ci u. 0 0 0 0 0 0 0 0 w w w w w w w !Xl Z UJ ..J ..J J: 0 >- C Z Z <C !:: :::l ..J () 0 W J: W :! () ~ e z ii: <C 0::: (J) r:x: :> 0::: ..J 0 UJ W W I- W J: J: u. w 3: c.. UJ ..J l- I- e ..J 0 ~ 0::: ..J 0::: :::l W :::l ..J :::l W 0 0 !Xl W u. C) J: ~ Z UJ z o - ..... <C :E ~ o LL Z wC/) ~w <cO:: ~~ ><m w- ........J -<C Ww ~~ .....<C z w C C/) w 0:: I Z o Z I- Z c( 0- U i= 0::: c( 0- :1: ~ C) en en en 0 en 0 en en 0 w w w w w w 0::: >- >- >- Z >- Z >- >- 0- Cl 0::: c( U w 0::: c( J: en >< w l- I- e e e e en c( C! c( c( e c( e c( e 0 - I.t) - - an - an - an z N Z Z N Z N Z N U ~ ~ ~ ~ e 0 Z W Z I W I ~ LL 11l C Cl CI) en 0 0::: E w e .l!l e c( U >- Z Z U . . C I - 11l CI) 11l C 11l :2 I- CI) CI) IV en 0 en IV en z E :E >< 11l W W >< W W U CI) ~ >- z >- CI) >- Cl CI) l- I- CI) - ... C - ~ - en Cl CI) 0 0 W c( E - c - 0::: c ~ C I ni CI) CI) 0 CI) z (.) CI) :2 u :2 ... 0 0 Cl 11l C 11l Z ... c( CI) CI) c.. ... 0 ... '(3 I - C >. c >. CI) 0 C CI) c 0::: Z c( Cl c( en ..J == J: Cl >- Cl Z Z c( !::: ::::> ..J U 0 W :I: W :1: u ::s::: Cl z ~ c( 0::: en 0::: :> 0::: ..J 0 en w w I- W J: J: LL W 3: 0.. en ..J l- I- Cl ..J 0 c( 0::: ..J 0::: ::::> w ::::> ..J 0::: ::::> w 0 0 CC W LL C) J: ::s::: Z en MEMORANDUM TO: Dianne McWethy, Deputy City Manager FROM: Mary E. Rodne, Library Director DATE: April 14, 2003 SUBJECT: Proposed Colleyville Public Library Circulation Policy In preparation of the Circulation Policy, staff reviewed comparable policies of local libraries. General basic guidelines included in most policies of libraries in this area were included in this policy. For this policy, several decisions have to be made. These include: loan periods for materials, item check out limits and fee charges. In consideration of the above, staff developed two charts: Circulation Materials Restrictions and Replacement and Processing Fees. In developing contents of these charts staff considered the following: 'jr Fees and circulation loan periods of area libraries 'jr Proposed collection size of the Colleyville Public Library On the basis of the above, staff proposed the attached Circulation Policy for consideration. COLLEYVILLE PUBLIC LIBRARY CIRCULATION POLICIES o BORROWING PRIVILEGES . ELIGIBILITY TO BORROW Individuals presenting valid Colleyville Public Library cards are eligible to borrow materials from the Colleyville Public Library when the following conditions are met: 1 . No materials which are more than one circulation period overdue on their card. 2. No outstanding fines in excess of the set threshold (Appendix A). The library staff may not waive these regulations without the specific permission of the Library Director or his/her designee; however, the patron may request and receive a 24-hour hold on the item(s) he or she wishes to check out to allow the patron to correct the situation, which has resulted in loss of eligibility to borrow. Waiver of these regulations will be granted only if proof of mitigating circumstances and proof of attempts to correct the situation are presented to the Circulation Supervisor or his/her designee. o LOAN PERIODS The library's basic loan period is 14 days. Materials excepted from the basic loan period may have loan periods of 3, and 7 days (Appendix A). Upon a patron's request, extended loan periods for vacations may be made at the discretion of a circulation staff member. Materials secured for a patron on Interlibrary Loan are governed by the circulation policies of the home library and must be returned to the home library on time. o LIMITS ON BORROWING The library reserves the right to limit the number of items in anyone subject area of anyone medium that may be checked out to an individual patron, on the basis of perceived demand for materials on that particular subject or in that particular medium (Appendix A). o RENEWALS Circulation Policy Revised 4/30/03 Page I of3 Most materials may be renewed, in person, by calling the Circulation Department or online by using the patron's library card number and Personal Identification Number (PIN). Library materials not reserved by another patron may be renewed for additional loan periods (Appendix B). Materials that are on reserve for another patron may not be renewed. Overdue materials will not be renewed without payment of any overdue fines. Interlibrary Loan materials that are overdue cannot be renewed. o DRIVE - UP WINDOW SERVICE The library has a drive-up window through which materials may be picked up during library operational hours. For this service, patrons need to call ahead and request staff to retrieve materials for window pick-up. o MATERIAL RETURNS The library has walk-up material returns inside the library and drive-up material returns outside the library. Patrons will be credited with the return of the item on the day it is put in the return. Items returned on a day the library is closed will be checked in the next day that the library is open. o OVERDUES Materials returned after their due date will be assessed an overdue fine (Appendix A) for each day the library was open between the due date and date of return. A fine will not exceed the replacement cost of an overdue item. Overdue notices will be sent out on the following schedule: 1st notice: 2nd notice: 3rd notice: after materials are 7 days overdue. after materials are 14 days overdue. after materials are 21 days overdue. If the materials are not returned one week after the 3rd notice is mailed, the patron will receive a letter revoking their borrowing privileges. o DELINQUENT PATRONS All borrowing privileges will be suspended if a patron accumulates fines in excess of the Library's threshold (Appendix A), or has unreturned materials for a period exceeding 21 days. Borrowing privileges shall be reinstated upon return of the materials and payment of the accumulated fees, or the payment of the replacement cost of the material and the accumulated fees. CIrculation Policy Revised 4/30103 Page 2 of 3 o LOST AND DAMAGED MATERIAL Borrowers are liable for the replacement cost of any library material lost, damaged or not returned. The charge for replacement shall be the cost of the material as noted in the item record of the Colleyville Public Library Online Catalog. A processing charge (Appendix B) will be added to all items. Borrowers who replace lost or damaged material with an exact copy will be charged a re-cataloging fee (Appendix B). Library staff will determine if the replaced material is an acceptable match. When material is returned with parts missing, the patron is responsible for the cost of the part (Appendix B). If the part is unavailable, the patron is liable for the replacement cost of the original material, plus a processing fee. o LOST AND PAID If a patron recovers library material that has been lost and paid for within one (1) month, the library will refund the cost of the material minus the processing fee. The returned material and the dated receipt of payment must be presented at the time of refund. CIrculation Policy Revised 4/30/03 Page 3 of 3 MATERIALS Fiction Books Non-Fiction Books Best Sellers Ma azines Pam hlets Feature Length DVDs (60 min+ Educational/DVDs Children's DVDs under 60 min. Com act Discs J Kits Books on Compact Disc J Holiday books APPENDIX A COLLEYVILLE PUBLIC LIBRARY CIRCULATING MATERIALS REST LOAN PERIOD LIMITS FEES/FINES* .25 per da .25 per day .25 per day *Overdue fines threshold is $5.00. ** Renewals are allowed when materials are not on reserve for another patron. 3 3 14 da s 7 days 3 3 5 3 3 7 days varies by Holida Appendix A Circulating Materials Restrictions Revised 4/30/03 RENEWAL L1MITS** 1 1 1 1 1 1 1 1 1 1 1 o during Holida APPENDIX B COLLEYVILLE PUBLIC LIBRARY ITEM COST PROCESSING FEE* Library Card $2.00 $0.00 Book Cost of item $5.00 Trade paperback book Cost of item $5.00 Paperback book Cost of item $2.00 Magazine Cost of item $2.00 Compact Disc Cost of item $5.00 Lost Insert Cost of item $1.00 Book on CD Cost of item $5.00 Lost/damaged CD Cost of sinQle CD $1.00 DVD Current cost of item $5.00 Audio-visual material containers Current cost of item $5.00 Bar Codes/RFID tags $1.00 $0.00 *If a replacement is purchased by the patron, the processing cost is $10.00 Appendix B: Replacement and Processing fees Revised 4/25/03 Page I of2 ORDINANCE 0-03-1404 AN ORDINANCE AMENDING ORDINANCE 0-92-880 SETTING FEES AND CHARGES FOR CITY SERVICES, ESTABLISHING SECTIONS OF THE CITY OF COLLEYVILLE CODE OF ORDINANCES, TO BECOME EFFECTIVE UPON PASSAGE WHEREAS, the City of Colleyville charges fees for miscellaneous services and materials as authorized by Ordinance 0-92-880 and it is desirous to add to those fees for the opening of the Colleyville Public Library. NOW, THEREFORE BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. THAT from and after the effective date of this Ordinance, Chapter 2 Section 2-26 (k) of the City of Colleyville Code of Ordinances shall be established with the following additions: (k) The following schedule of fees shall be administered by the Library Director: Colleyville Public Library Circulating Materials Restrictions (see attached Exhibit "A") Colleyville Public Library Replacement and Processing Fees Materials (see attached Exhibit "8") Sec. 2. THAT this ordinance is effective upon passage. AND IT IS SO ORDERED. The first reading and public hearing being conducted on the of 2003. day The second reading and public hearing being conducted on the of 2003. day ATTEST: CITY OF COLLEYVILLE: Cynthia Singleton, TRMC City Secretary Mayor Ordinance 0-03-1304 Page 2 of 2 APPROVED AS TO FORM AND LEGALITY: Ross T. Foster City Attorney EXHIBIT "A" COLLEYVILLE PUBLIC LIBRARY MATERIALS LOAN PERIOD LIMITS FEES/FINES* RENEWAL L1MITS** Fiction Books 1 Non-Fiction Books 3 1 __ __ ____m___H____~~._.~___.~____ Best Sellers 1 Ma azines 3 1 Pam hlets 1 Feature Length 1 DVDs 60 min+ Educational/DVDs 14 da s 3 1 Children's DVDs 7 days 3 1 under 60 min. Com act Discs 5 1 J Kits 3 1 Books on Compact 3 1 Disc J Holiday books 7 days varies by .25 per day o during Holida Holida *Overdue fines threshold is $5.00. ** Renewals are allowed when materials are not on reserve for another patron. EXHIBIT "A": Circulating Materials Restrictions Revlsed4/30/03 EXHIBIT "B" COLLEYVILLE PUBLIC LIBRARY REP ITEM COST PROCESSING FEE* Library Card $2.00 $0.00 Book Cost of item $5.00 Trade paperback book Cost of item $5.00 i Paperback book Cost of item $2.00 Magazine Cost of item $2.00 Compact Disc Cost of item $5.00 Lost Insert Cost of item $1.00 Book on CD Cost of item $5.00 LosUdamaged CD Cost of sinQle CD $1.00 DVD Current cost of item $5.00 Audio-visual material containers Current cost of item $5.00 Bar Codes/RFID tags $1.00 $0.00 *If a replacement is purchased by the patron, the processing cost is $10.00 FX:IIII~IT .. H" Rcpl8ccment and Processing lees RevIsed 4/25/U3 P8g.e I of 2 CITY COUNCIL cur Of CCe'" AGENDA BRIEFING 1(,-.'\:.,$ MEETING DATE: ITEM # : RESOLUTION # : 05/06/03 10 R-03-2143 CITY MANAGER I DEPARTMENT HEAD I FINANCE REVIEW ! · Previous Action: None DEPARTMENT: ENGINEERING SUBJECT: Approval to amend Resolution R-02-1925 Authorizing the Approval of the 2001 Drainage Bond Project List Reading and Public Hearing In January 2001, the City Council approved the 2001 Drainage Bonds and in March 2002 approved the Drainage Bond Priority List for the utilization of these bond funds. (See attached). To date, several of the projects have been completed. The Jackson Road and Cheek Sparger Road project is on hold. City resources will be used to complete the Cheek Sparger and San Bar drainage improvements. The Bedford Road and Saddlebrook Entrance project was funding with available MDUS funds for FY2002-03. Two of the projects (Jewell Estates and Stonecrest) required less funding than the estimates. Staff is proposing that the Drainage Bond Project List be amended to include funding for the Welsh Circle drainage and related paving improvements in the amount of $102,763. (See attached). Recommendation Approval Attachments · Resolution R-02-1925 · Resolution R-03-2143 RESOLUTION R-02-1925 A RESOLUTION AUTHORIZING THE APPROVAL OF THE 2001 DRAINAGE BOND PROJECT LIST WHEREAS, In January 2001, City Council approved the 2001 Drainage Bonds; and WHEREAS, In February 2001, a worksession was held with City Council to discuss drainage problems and total construction cost estimates with the intent of generating a project list; and WHEREAS, In February 2002, a worksession was held with City Council to present a project list with estimates and construction schedules for ten (10) drainage projects identified from the Master Drainage Priority List; and NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. THAT the Drainage Bond Priority List, hereby referred to as Exhibit" A" for the 2001 Drainage Bonds. is hereby approved. AND IT IS SO RESOLVED. PASSED BY A VOTE OF 5 AYES, 0 NAYS, AND 0 ABSTENTIONS ON THIS THE /9~ DAY OF ~..., 2002. ATTEST: t2 Sin9~lon, City Secretary .~ CITY OF COllEYVlllE ~;Np Mayor Exhibit "A" Drainage Bond Project Priority List Projects Estimates > John McCain Road @ Hwy 26 Realignment $450,000.00 > Jewel Estates Drainage Improvements 380,000.00 > Little Bear Creek Restudy and Letter of Map Revision 50,000.00 > Jackson Road Drainage Improvements (Cheek Sparger and 200,000.00 Jackson Road Intersection Improvements) > L.D. Lockett Drainage (Hunter Trail to Quality Hill) 100,000.00 > Felps Drive (flooding of private residence) 75,000.00 > Cheek-Sparger and Sanbar Drainage Improvements 100,000.00 > Stonecrest Estates Drainage (private property damage) 75,000.00 > Bedford Road @ Saddlebrook Entrance (groundwater) 25,000.00 > John McCain Road Channel Improvements 20,000.00 (adjacent to Coptic Church) Total $1,475,000.00 RESOLUTION R-03-2143 A RESOLUTION AMENDING RESOLUTION R-02-1925 AUTHORIZING THE APPROVAL OF THE 2001 DRAINAGE BOND PROJECT LIST WHEREAS, the City Council desires to amend the Drainage Bond Project List to address drainage problems within the City. NOW, THEREFORE, BE IT RESOLVED BY CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. THAT the 2001 Drainage Bond Project List, hereby referred to as Exhibit "A" for the 2001 Drainage Bonds, is hereby approved. AND IT IS SO RESOLVED. PASSED BY A VOTE OF THIS THE DAY OF AYES, NAYS AND 2003. ABSTENTIONS ON ATTEST: CITY OF COLLEYVILLE: Cynthia Singleton, TRMC City Secretary Mayor Exhibit A Drainage Bond Project Priority List The following drainage project list has been revised to show actual costs or project status: Total Bond Monev Available: Projects: >- John McCain Road @ Hwy 26 Realignment >- Jewel Estates Drainage Improvements );> Little Bear Creek Restudy and Letter of Map Revision );> Jackson Road Drainage Improvements (Cheek-Sparger and Jackson Road Intersection Improvements) );> L.D. Lockett Drainage (Hunter Trail to Quality Hill) >- Felps Drive (flooding of private residence) >- Cheek-Sparger and Sanbar Drainage Improvements >- Stonecrest Estates Drainage (private property damage) );> Bedford Road @ Saddlebrook Entrance (groundwater) );> John McCain Road Channel Improvements (adjacent to Coptic Church) New Project: );> Welsch Circle & Montford Drive Drainage Improvements Projects Estimate Money Available Actual Project Costs Balance $1~600~OOO Estimate (Actual) $650,000 (pending) $380,000 ($215,000) $50,000 <$52,000> $200,000 (on hold) $75,000 <$230,000> $50,000 (pending) $75,000 (City crews) $50,000 ($23,000) $25,000 (other $$) $20,000 (pending) $102,763 (Pending) $1.575.000 (estimate) $1.600.000 $1.240.763 (actual) $359,237 CITY COUNCIL cc@n~ AGENDA BRIEFING 1C";(:tS MEETING DATE: ITEM # : RESOLUTION# : 05/06/03 11 R-03-2144 ! CITY MANAGER i I DEPARTMENT HEAD I I FINANCE REVIEW I ; Previous Action: None DEPARTMENT : ENGINEERING SUBJECT: Approval of a Construction Contract for the Welsh Circle Paving Improvement Project with J. L. Bertram Construction and Engineering, Inc., in the amount of $102,763 Reading and Public Hearing In February 2002, City Council approved a list of ten projects to utilize the $1.6 million in drainage bond funds. Over the past year some of the projects included in the original list have been constructed and completed below the engineer's estimates. This has allowed some additional projects to be considered for construction with the remaining funds. Staff met with citizens in the fall of 2002 at Welsh Circle and Montford Drive regarding standing water and improper drainage within the roadway. The current roadway has developed a sag in the gutter line and holds rainwater for weeks at a time until it evaporates. During the rainy season it will not dry up. The streets are asphalt and water has continued to undermine the road at this location causing deterioration of the subgrade, resulting in a greater problem. Construction will consist of removing and replacing the existing pavement with concrete and adjusting the grade to create positive drainage. All driveways, irrigation systems and mailboxes adjacent to the improvements will also be adjusted. Staff has met with the citizens and discussed the proposed improvements. Comments were received and addressed and the project was advertised in March 2003. Three bids were received and opened on March 25, 2003, with Boatner Construction Services being the low bid. However, numerous attempts to collect necessary background information and references from Boatner failed. Also, their bonding company is not listed with the U.S. Treasury; therefore, Boatner Construction Services was deemed non-responsive and the second low bidder, J.L. Bertram Construction and Engineering, Inc. was selected for consideration. The contract amount is $85,635.56 with a 20% contingency of $17,127 for a total of $102,763. A 20% contingency is needed due to the work being performed in a residential area. The City Attorney has reviewed and approved this contract. Agenda Briefing Resolution R-03-2144 Page 2 of 2 Financial Impact Funding is available from the 2001 Drainage Bonds Recommendation Approval Attachments . Bid Tabulation . Resolution R-03-2144 BID TAB Owner: City of Colleyville Engineer: Teague, Nail, & Perkins Project: Welsh Circle Paving Improvements Bid Date: Tuesday, March 25, 2003 No. Bidder Bid Bond Bid Amount 1 Boatner Construction Services $66,126.00 2 J.L. Bertram Construction & Engineering, Inc. $85,635.56 3 Humphrey & Morton Construction Co., Inc. $94,841.60 4 5 6 7 8 RESOLUTION R-03-2144 A RESOLUTION AUTHORIZING THE APPROVAL OF THE CONSTRUCTION CONTRACT WITH J.L. BERTRAM CONSTRUCTION & ENGINEERING, INC., FOR THE WELSH CIRCLE PAVING IMPROVEMENT PROJECT WHEREAS, the construction bids for the Welsh Circle Paving Improvements were received on March 25,2003; and WHEREAS, three bids were submitted; and WHEREAS, J.L. Bertram Construction & Engineering, Inc., is the selected bid. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. THAT the construction contract with J. L. Bertram Construction & Engineering, Inc., for the Welsh Circle Paving Improvement Project, in the amount of $102,763, is hereby approved. AND IT IS SO RESOLVED. NAYS, AND 2003. PASSED BY A VOTE OF ABSTENTIONS ON THIS THE AYES, DAY OF ATTEST: CITY OF COLLEYVILLE Cynthia Singleton, TRMC City Secretary Mayor CITY COUNCIL ccecel AGENDA BRIEFING 'C':ens I MEETING DATE: I I 05/06/03 12 R-03-2145 CITY MANAGER I I ITEM # : i i RESOLUTION # : ! DEPARTMENT HEAD I I FINANCE REVIEW i Previous Action: None DEPARTMENT: PUBLIC WORKS SUBJECT: Approval of an Interlocal Agreement with Tarrant County for Glade Road, Rose Street, Cherry Avenue, Lowrie Road and Reagan Road improvements, in an amount not to exceed $65,000 Reading and Public Hearing The City of Colleyville has entered into several interlocal agreements with Tarrant County in recent years regarding road improvements. Bransford Road south of L.D. Lockett (1999), Bandit Trail (2002) and including John McCain Road (2003). Each project was completed at a considerable cost savings to the City. The County provides all of the labor and equipment to conduct the improvements and the City is responsible for traffic control and material testing. Tarrant County is in the process of setting their summer construction schedule. The City has submitted to the County a list of roads that include: 1) the west end of Glade Road; 2) Rose Street; 3) Cherry Avenue; 4) Lowrie Road; 5) Reagan Road. The repair work will include the removal and haul off of the existing top course of asphalt, stabilizing, re-grading and re- compacting the subgrade and applying a 2-inch HMAC overlay. This type of project is a new addition to the City's annual street rehabilitation program and is consistent with the Colleyville Public Works Department procedures. The remaining street rehabilitation fund balance will be used this summer for repairs in other locations in which Tarrant County cannot participate due to workload issues. Financial Impact Funding is available from the Street Department Resurfacing Budget (001-33-6319). Recommendation Approval Attachments . Interlocal Agreement . Cost Estimate . Resolution R-03-2145 THE STATE OF TEXAS KNOW ALL MEN BY THESE PRESENTS COUNTY OF TARRANT CONTRACT This Agreement made and entered into this the day of , 2003, by and between the County of Tarrant, acting herein by and through its governing body the Commissioners Court, hereinafter referred to as TARRANT COUNTY, and the CITY OF COLLEYVILLE acting herein by and through its governing body, hereinafter referred to as THE CITY, both of Tarrant County, State of Texas, witnesseth: WHEREAS, this Agreement is made under the authority granted by and pursuant to Chapter 791 ofthe Texas Government Code; and WHEREAS, the party or parties paying for the performance of governmental functions or services shall make payments therefore from current revenues available to the paying party; and, WHEREAS, the governmg bodies of the two parties find that the project or undertaking is necessary for the benefit of the public and that each party has the legal authority to build or maintain the project or to provide such service, and the construction and improvement thereof is in the common interest of both parties hereto; and that the division of costs provided for constitutes adequate consideration to each party; set project being more particularly described as: . Construction of a HMAC overlay on Glade Road, west of the Mill Creek Sub- Division (approximately 350 linear ft.). . Rehabilitation of Lowrie Road, from L.D. Lockett Road to the Tarrant County maintenance line (approximately 1228 linear ft.). . Rehabilitation of Reagan Road, from L.D. Lockett Road to the Tarrant County maintenance line (approximately 1228 linear ft.). . Rehabilitation of Cherry Avenue, from Bluebonnet Road to the end of street (approximately 1273 If.). . Rehabilitation of Rose Street, from Glade Road to Cherry Avenue (approximately 1025 linear ft.). WHEREAS, the parties hereto, in order to facilitate the financing and construction of the needed facility, and in order to share the costs of having said work to be done have agreed to share in the financing of said construction as hereinafter stated in detail. The CITY hereby agrees that the CITY will pay for any engineering, survey, and laboratory testing necessary for these projects, and that the COUNTY will not be responsible for any payment for such services. The CITY must notify the COUNTY within thirty days of completion of this project of any complaint the CITY has with the project. For and in consideration of the mutual undertaking hereinafter set forth and for adequate consideration given, the parties agree as follows: 1. TARRANT COUNTY agrees to provide the work for the following projects: A. Glade Road. Remove the existing HMAC surface and place a two-inch HMAC overlay surface. R Lowrie Road: Reclaim the existing roadbed materials, incorporate and stabilize the recycled base material with cement, re-grade and place a two-inch HMAC surface. C. Reagan Road: Reclaim the existing roadbed materials, incorporate and stabilize the recycled base material with cement, re-grade and place a two-inch HMAC surface. D. Cherry Avenue: Reclaim the existing roadbed materials, incorporate and stabilize the recycled base material with cement, re-grade and place a two-inch HMAC surface. E. Rose Street: Reclaim the existing roadbed materials, incorporate and stabilize the recycled base material with cement, re-grade and place a two-inch HMAC surface. 2. TARRANT COUNTY agrees to provide the labor and equipment necessary for the rehabilitation work of above projects. 3. The CITY agrees to pay for the actual cost of the materials, including any delivery or freight costs. The CITY will provide a purchase order and will be billed directly by the material supplier. The County may accumulate and bill the City for incidental material cost. 4. The CITY agrees it will be responsible for traffic control on these projects. This responsibility includes all signage, barricades and flagmen necessary to control traffic in and around the construction site. The CITY will also be responsible for all striping (both temporary and permanent) for the project. 5. The CITY will provide the county with a hydrant meter and all the water necessary for the projects at no cost to the county. 6. The CITY will be responsible for all storm water pollution documentation and for installation, maintenance and removal of all storm water pollution prevention devices as required. By entering into this Agreement the parties do not create any obligations express or implied other than those set forth herein and this Contract shall not create any rights in parties not signatories hereto. The parties to this Agreement do not intend by this Agreement that any specific third party may obtain a right by virtue of the execution or performance of this Agreement. CITY agrees that the COUNTY is relying on the CITY for notice of when to proceed with these projects, but this Agreement does not require the County to do these projects with any particular time frame. This Agreement shall terminate automatically upon happening of any ofthe following events: 1. The completion of the improvement provided for herein or; 2. At the end of one (1) year from date herein, unless renewed by both parties in writing. CITY: Authorized City Official ATTEST: CITY TARRANT COUNTY: TOM VANDERGRIFF, County Judge ATTEST: COUNTY B. GLEN WHITLEY, County Commissioner Precinct Three * APPROV AL AS TO FORM: District Attorney's Office * By law, the District Attorney's Office may only advise or approve contracts or legal documents on behalf of its clients. It may not advise or approve a contract or legal document on behalf of other parties. Our review of this document was conducted solely from the legal perspective of our client. Our approval of this document was offered solely for the benefit of our client. Other parties should not rely on this approval, and should seek review and approval by their own respective attorneys. 2003 Overlay Project w I Tarrant County Cost Summary .1II1..Il~II.IIII~t1ml~:...um Glade Rd Cher Avenue Rose St Lowrie Rd Rea an Rd subtotal 10% contingencies $2,810 $16,201 $12,187 $14,209 $13,119 $58,526 $5,853 $64,379 Total The Cit The Cit The Cit 350 1273 1025 1228 1228 5104 RESOLUTION R-03-2145 A RESOLUTION AUTHORIZING THE APPROVAL OF AN INTERLOCAL AGREEMENT WITH TARRANT COUNTY FOR GLADE ROAD, ROSE STREET, CHERRY AVENUE, LOWRIE ROAD AND REAGAN ROAD STREET REPAIR IMPROVEMENTS WHEREAS, Tarrant County will perform repair work at the west end of Glade Road, Rose Street, Cherry Avenue, Lowrie Road and Reagan Road; and WHEREAS, Tarrant County will provide the labor and equipment required to construct the planned improvements; and WHEREAS, the City will provide the materials testing, traffic control during the construction; and WHEREAS, the City will issue a notice to proceed for the County to begin after approval of the interlocal agreement; and WHEREAS, the work will be completed by the end of September 2003. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. THAT the Interlocal Agreement with Tarrant County for street repair improvements, in the amount not to exceed $65,000, is hereby approved. AND IT IS SO RESOLVED. PASSED BY A VOTE OF THIS THE DAY OF AYES, NAYS AND 2003. ABSTENTIONS ON ATTEST: CITY OF COLLEYVILLE: Cynthia Singleton, TRMC City Secretary Mayor CITY COUNCIL c\tYor CC~~ll AGENDA BRIEFING IL'X~S MEETING DATE: ' ITEM # : RESOLUTION # : 05106/03 13 R-03-2124 CITY MANAGER I DEPARTMENT HEAD FINANCE REVIEW I DEPARTMENT: COMMUNITY DEVELOPMENT SUBJECT: Reconsideration of the City Council action taken on a request for waiver of perimeter street improvement requirements on Lot 3R, Block 2, Thompson Terraces, located at 5009 Thompson Terrace Previous Action: Tabled 04/15/03 Update The City Council tabled action on this request when the applicant was called away from the meeting unexpectedly and was not available to finalize the discussion regarding his request for a waiver of the perimeter street improvement costs. Additionally, there was misunderstanding regarding the method for applying perimeter street improvement costs to reduce roadway impact fees. The property contains approximately 180 linear feet of street frontage, which after applying the per-front costs of $134.98, requires a perimeter street improvement cost of $24,295.50. Since Thompson Terrace is a collector street shown on the Master Thoroughfare Plan, the actual perimeter street improvement costs are used to reduce any applicable roadway impact fees collected at time of building permit. The applicant proposes to construct a new office building on the property containing 4,689 square feet, which would require the collection of a $12,107 roadway impact fee ($2,582 per 1,000 s. f. of floor area). State laws pertaining to roadway impact fees require developers be given credit against roadway impact fees for any perimeter street improvement costs. Thus, the roadway impact fee is reduced to zero, and the developer would pay the perimeter street improvement costs. The developer is requesting a waiver or reduction of the $24,295.50 perimeter street improvement costs. Reading and Public Hearing At the April 1, 2003, meeting, the City Council denied a request for a waiver of perimeter street improvement requirements for property located at 5009 Thompson Terrace. The applicant, Dr. Jonathan Richard, was not able to attend the April 1 meeting due to family medical reasons. He has submitted a letter asking that the City Council reconsider the request so he may present his case and discuss the issue with the Council. A copy of the letter is attached. Dr. Michael Richard is the owner of a lot located on the east side of Thompson Terrace, between Glade Road and Colleyville Boulevard. The owner submitted a minor plat of the property that created one non-residential lot for the construction of a medical office. The Planning and Zoning Commission approved the minor plat at the December 2, 2002 meeting. Agenda Briefing Resolution R-03-2124 Page 2 of 2 The owner is seeking a waiver of perimeter street improvement requirements for this property. Dr. Richard does not own any contiguous property, and a letter from the owner is attached that describes this request in further detail. The owner dedicated 1,350 square feet of right-of-way for Thompson Terrace on the plat. Thompson Terrace is identified for future widening on the Master Thoroughfare Plan, though no plans for improvement have been authorized. The future right-of-way for Thompson Terrace is 75 feet. Thompson Terrace is an asphalt street without curb or gutter. The future street would be constructed of concrete. The following tables show the pertinent data relative to this request. Perimeter Street Improvement Cost Estimate STREET FRONTAGE TOTAL ESTIMATE ACTUAL COST PER LINEAR FOOT Thompson Terrace 180.0 feet $ 24,295.50 $134.98 One of the responsibilities of a property owner when property is proposed for platting is to make improvements to adjacent streets if the streets are not currently constructed to City codes. Generally, streets are considered unimproved if the street is not concrete and does not have curb and gutter. Instead of improving the streets, the owner may escrow an equivalent amount of money with the City to meet this requirement. The escrow amount, which is based on the City's costs to construct a similar type of roadway, includes both construction and engineering design costs. Dr. Richard has appealed this requirement as allowed by the Land Development Code. The Land Development Code gives the City Council the authority to consider a waiver from this regulation, as the Council is the appeals body for Chapter 9 of the Code, in which this regulation is contained. The City Council's options in this case are the following: 1. Approve the waiver as requested - This action would waive the perimeter street fee requirement for this property in the amount of $24,295.50. 2. Approve the waiver in part - The Council may waive a portion or percentage of the fee. 3. Denv the waiver - The property owner must escrow $24,295.50 with the City before building permits could be issued on the property. Recommendation Denial Attachments · Location Map · Letter from Applicant · Property Map · Resolution R-03-2124 10 ~I ' ~. CO I,\.. @ - '2'\; ~ I\.. l3?t "el ~\3' . S~~20G . . TR 4Al : .58 .., AC : II{; , . TR U I. IS At TR ]t .61 At ) ~Ot8>O\.. 'l SC 1 I 8._ . :P 1l\?J .J 0\..501'1 p (1 SiJF\l2~B ~.. (-I' 1 ~ ..... of\R1< 'f~Fr Cf.~ r.. VVt'l_ t" .....-;:;"f) on 8,QI)"4 . _ cz, '( ~otJ _...,1. l\. Location Map CASE # P-02-045 - Amended Plat - Thompson Terraces April 7, 2003 To Whom it May Concern: We would respectfully request the city council to reconsider ourrequest for waiver for the assessment of street improvements as outlined in our letter of March 6, 2003. Due to medical reasons, we were unable to attend the city Council meeting of last Tuesday, April 1st. We would like to be able to present our position in person and discuss any alternatives that might be in both of our interests. ;~C;rlY, \.. ...' / ,/ 'It a~ an & Marietta Richard R' EC.E'ED' I r~~ 8Z~ l ' \ ~ _______ - -. J ! u IY OF COlLEYVILL- '>,)MIVlUNiTi DEVELOt)..,,\HH March 5, 2003 City of Colleyville 5400 Bransford Rd. P.O. Box 185 Colleyville, Texas 76034 RE: Richard property on Thompson Terrace I am a long time resident of Colleyville and the current owner of the property at 5009 Thompson Terrace. At considerable time and expense I have endeavored to develop this property to better meet the needs of my patients and keep my practice within the city of Colleyville. As I have 3000 active patients coming to my office from over 12 nearby cities, the development of this property will be convenient for my patients and greatly enhance the visibility of other small business in downtown Colleyville and the nearby Villages of Colleyville. I submitted a minor plat to the City of Colleyville to combine two lots into one in order to build a small professional office building. The Planning and Zoning committee approved the plat at the October 12, 2002 meeting. After completing the platting process and donating the right of way to the City for future street improvements, I was surprised to find that I was still required to pay a $25,000 fee for additional improvements. As a solo practioner with a small medical practice, which requires over 80 hours per week of my time, this is a huge financial burden. Due to the increasing time and financial pressures of running a medical practice, had I known about this additional expense from the beginning, I probably would not have pursued the development of this property in Colleyville. I am concerned that further delay and additional expense may adversely impact my ability to meet the needs of my patients, therefore, I am requesting that the City Counsel grant a waiver of the perimeter street improvement requirement for this plat as allowed by the Land Development Code. . ~,erel~ J6nathan Richard, M.D. IR ErE' '''0' '. ,>-" . ~ : -".. r~m 12003 T I I... c ...< .-..... ... .': j 'l (I f rOll l (VIt,I ~,1~! INri DE'IF! ',;i I '/2. I I I /J!F. I I I I. 60.08' I I I; I I ~I. t;jl w :1 '" I!! I z ---I ~I I w I u <( I 0:::: I 0:::: W l- I Z I 0 if) I 0.... I ~ ___---l 0 I J: I l- I I I I I. I 60.04' I I --~/~ I I I I I I I I I I I I I : 1~ ~~NAOC ~~~T I VOL 388-11, PG. !!It ~~.~:_-~~;--+-J~~~~~~~~j~~;~~~~~~~~~~~~," ~ -- --~-109~----- 1/2"'RF- - -----i--------~------------------l P.D.B. 1 T I I I I : I ~I I~ I i I~ CO ~ I I -I I I I · , : i I I~ I : 1 I; I i ~ I I'i : ! I Q I I - I ~ I .. I 1 ai I I rl 1 I~ so C) C) I i II! I .:1'1; . . LOT 3R eo ~,,,,:i:,: !! 15 0.4504 AC. (19.620 sa. FT.) I! I I I : I ~ : ! I : ! I ~ I I : ~ I I 1 ~ I I " I I ill' : i 1 I 1 j!:1 I I : L- -- ~I I~ : i 18 ':~ I I I I lei I I : 1!1 '/2' I""j 1_ 109.00' ---.L-=:l · ~O~ - +- - - ---P"CPE"~ ~ - - - - 'WEST'"II'/2. I,.,. I I : I I I I I I : I : I LOT 2 : I : I BLOCK 2 : THOMPSON TERRACES I VOL. 388-1', PG. 81 : P.R. T.C. T. I : I : LOT 5 I ',\ L i --j 37.50' I f ~ ,~ 1;: :~~ '>1 ~ * i ~ ~' t.' \'< :~ i' ~. ~ f '* 1f~ ~ '~ If 1fi *" ~. ~' '\ ~ ~: .~ l j j,i; %. ~ ;iti' ~ .~ i I ,~ -it . RESOLUTION R-03-2124 A RESOLUTION APPROVING A WAIVER OF PERIMETER STREET IMPROVEMENT REQUIREMENTS FOR LOT 3R, BLOCK 2, THOMPSON TERRACES NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. THAT the City Council has reconsidered the action taken on the denial of the waiver of perimeter street improvement requirements at the April 1, 2003 meeting; and Sec. 2. THAT the perimeter street improvement requirements for Lot 3R, Block 2, Thompson Terraces, are hereby waived. AND IT IS SO RESOLVED. NAYS AND 2003. ABSTENTIONS ON PASSED BY A VOTE OF THIS THE DAY OF AYES, ATTEST: CITY OF COLLEYVILLE: Cynthia Singleton, TRMC City Secretary Mayor .~ Texas PLANNING AND ZONING COMMISSION MEETING MINUTES - MARCH 24, 2003 CALL TO ORDER Chairman Wall called the meeting to order at 7:00 p.m. ROLL CALL Commissioners Bruce Kelly, Earl Swift, Jeff Byerly, Bud Seller, Mark Jones, and Jeff Wall were present. Barry LeBaron, Clayton Husband, Jeff Jones, and Jan Levy from staff were present. INVOCATION The invocation was given by Commissioner Swift PLEDGE OF ALLEGIANCE APPROVAL OF MINUTES March 10,2003 Commissioner Swift moved to approve the minutes as amended to add a statement to the motion on item #4. Commissioner Byerly seconded the motion. The motion passed by unanimous acclamation. CITIZEN COMMENTS There was none. AGENDA ITEMS Chairman Wall announced that the applicant for agenda item 4 has requested that the Planning and Zoning Commission not take action on the case, but table the case do to the fact that the architect for the project would not be able to attend the meeting. He said it would not be fair to the people who came to speak about the case nor to the applicant to hold the public hearing since the applicant could not respond to the speakers. Chairman Wall moved to table item #4, Case Z-03-008, until the April 14, 2003 meeting. Commissioner Jones seconded the motion. The vote being: Ayes: Kelly, Swift, Byerly, Sellers, Jones, Wall Noes: None Chairman Wall advised staff to resend the notice of public hearing to the surrounding property owners. Planning & Zoning Commission Minutes - March 24, 2003 Page 1 of 8 Approved on Apri/14, 2003 1. Case P-03-008 - Minor Plat of Mockingbird Hill Addition, 10.6898 acres located on the west side of Pool Road in the 3400 block Clayton Husband presented the case to the commissioners and reviewed the staff briefing. There were no questions by the commissioners. Commissioner Kelly moved to approve the minor plat. Commissioner Swift seconded the motion. The vote being: Ayes: Kelly, Swift, Byerly, Sellers, Jones, Wall Noes: None 2. Case Z-03-006 - PUBLIC HEARING - Zoning Change from CN to PUD-R, 2.05 acres located at the northeast corner of Cheek Sparger Road and Steeplechase Drive Clayton Husband presented the case to the commissioners and reviewed the staff briefing. Commissioner Sellers asked Fire Marshal Jones if he was satisfied with the one entrance into the subdivision and about the turning radius. The Fire Marshal said the Land Development Code does not require more than one entrance for only ten lots and the houses are not required to have interior fire sprinkler systems. He said the street is not long enough to require a full turning radius in the cul-de-sac. Commissioner Jones said there are unique parcels in the city yet to be developed and he is in favor of bending a few rules in order to develop those properties; however, this proposal appears to be fracturing the rules. Staff responded there are other approved developments that have similar lot sizes. They mentioned the Villas at Caldwell's Creek and Westgate Villas; however, these subdivisions have open space and the proposed subdivision does not. Chairman Wall opened the public hearing. Those present wishing to speak were: Jimmy Schnurr, applicant. Commissioner Jones asked if it was possible to have open space in the subdivision. Mr. Schnurr said it was not economically viable. He explained that Boardwalk Homes is purchasing the property under commercial rates, yet they believe strongly the area is a residential area and not designed for commercial development. He said it is not a good commercial site as it has residential development on three sides. He explained there would be ten custom-built single family homes, with no two story structures, in the $300,000 range. Mr. Schnurr said the only access to the property is from Cheek Sparger Road since Bridlewood Estates owns the brick wall that runs along the western property line. He said that a commercial development on the property would generate more traffic than ten residential lots. He said he spoke with Bridlewood Estates, The Woods of Colleyville, Wood briar Estates and Saddlebrook Estates Home Owner Association representatives and the developer plans to mirror the Bridlewood HOA deed restrictions. He said this would be a high quality project that will benefit the area. Planning & Zoning Commission Minutes - March 24, 2003 Page 2 of 8 Approved on Apri/14, 2003 Commissioner Sellers asked about the positioning of garages. Monty Thomason, Vice President of Boardwalk Homes, explained this would not be a gated community and the average home would be approximately 2,400 square feet and start at $290,000. He said there would be no front entry garages, but they would probably have a front swing garage entry. Jo Ann Gasper, 4103 Paddington Way, said she would like the property to develop residential; however, there may be a line of sight problem when existing off Steeplechase. She expressed concerns about density and she encouraged the Commission to include the deed restrictions within the approving ordinance. Steve Knight, 3917 Felps Court, expressed concerns about commercial zoning in the area and said he believed that residential would be the highest and best use of the property. He said he has concerns about the density and said the developer commented that fewer lots were not viable because of the commercial rates. He said the developer should not pay commercial rates and he advised the Bridlewood homeowners to hold out for a better proposal for a residential subdivision on the property with fewer lots. He said they should not feel as if this is the only thing that could be developed on the property. Tom Caunitz, 4006 Steeplechase Drive, said his house would face the back corner of the development and he would be looking at the rear of houses. He said when he saw the pictures of proposed home designs, he thought there would be nice looking houses, but he is concerned about the number of houses. Pam Brandon, 3608 Briarbrook Court, said she is the president of the Woodbriar Homeowners Association and they discussed the proposal at a Board meeting. She said there are concerns about the speed of cars on Cheek Sparger and the number of accidents due to the curve in the roadway. She said something needs to be addressed about the road alignment for safety reasons. Steve Lingard, 301 Bridlewood South, said he lives on the corner on Lot 1. He asked questions about the distance from the fence to the rear of the houses, and about the proposal for a 112 story house on the rear lots within the subdivision. He said he did not want someone to have full view into his property. Mr. Lingard also expressed concerns about traffic and speeding on Cheek Sparger. Robert Peters, 4000 Steeplechase Drive, said he would also be facing the back yards of the proposed homes. He said he sent a letter to the commissioners proposing a different layout for the subdivision that will create a horseshoe drive around the houses. There being no one else present wishing to speak, the public hearing was closed. Commissioner Swift said he thinks that single family homes should be built in this area; however, he has issues about density, lack of open space, and the precedent it will set by creating such a high density with the adjoining property that still has the potential for being developed. He said this would be a big mistake. Planning & Zoning Commission Minutes - March 24, 2003 Page 3 of 8 Approved on Apri/14, 2003 There was discussion about the vacant lots in the area and the plans for development in the area. Commissioner Kelly said the Master Plan is currently being updated and they have no way of knowing what that plan will look like. He said the concerns about traffic are valid and if this property is developed, the traffic may turn out into an area of Cheek Sparger that needs to be aligned as required by a new Master Plan. Commissioner Jones moved to deny the zoning change. He said the area may be appropriate for residential development, but there are too many other issues with the request. Commissioner Swift seconded the motion. The applicant addressed the Commission and asked that the request be tabled so that they may continue to work with the surrounding neighbors and address their concerns. Commissioner Jones withdrew his motion. Commissioner Swift said he would not remove his second. It was determined that Commissioner Jones' withdrawal did not require Commissioner Swift to withdraw his motion to be valid. Commissioner Byerly moved to deny the zoning change. Commissioner Swift seconded the motion. The vote being: Ayes: Swift, Byerly Noes: Kelly, Sellers, Jones, Wall [Note: The motion to deny was not approved.] Commissioner Sellers moved to table the case until the April 14, 2003, meeting. Commissioner Jones seconded the motion. The vote being: Ayes: Kelly, Sellers, Jones, Wall Noes: Swift, Byerly 3. Case Z-03-007 - PUBLIC HEARING - Special Use Permit for an accessory building on 10.272 acres located at 816 L.D. Lockett Road Clayton Husband presented the case to the commissioners and reviewed the staff briefing. Chairman Wall asked staff how often a building that requires a special use permit is built without a permit. Staff responded that a building this size being built without a permit is unusual. He said the City's recourse is to require the owner to apply for a special use permit and go through the process of public hearings and if the special use permit is not granted, they would have to comply with the size regulations in the Land Development Code. Chairman Wall opened the public hearing. Those present wishing to speak were: Planning & Zoning Commission Minutes - March 24, 2003 Page 4 of 8 Approved on Apri/14, 2003 Marty Stajduhar, 101 Williamsburg Court, the applicant. He said he bought the land for the sole purpose of having horses and growing coastal hay so that he could get an agricultural tax exemption. Mr. Stajduhar said he used a contractor from Alvarado to build a covered area so that the horses could be ridden in all types of weather. He said the contractor informed him that a permit was not needed because the land was agricultural and used for agricultural purposes. Mr. Stajduhar apologized that he never talked to staff to confirm the information provided by the contractor. He said the information provided by the contractor made sense to him because of the lay of the land and the adjoining properties. He said there was a dilapidated house on the property that they tore down, but they left the pump room and have considered building a house on the property and living on the land in the future. He said there was no malicious intent, only misunderstanding. Commissioner Sellers asked Mr. Stajduhar about the covered arena. He responded that they now have loafing shed stalls and they want a closed area for the tractor and equipment. He said there is a 10' x 10' stone building that may be removed, and the structure that was built was not prefabricated. Lorraine Gohr, 809 Lavaca Trail, spoke in favor of the special use permit. She said since the Stajduhar's have purchased the property, they have cleaned up the property, have put in very safe fencing, and take excellent care of the property. She said they provide a facility that handicapped riders can use, and neighbors help with that endeavor. She said the Stajduhar's and the riding arena are an asset to the community and she wants the rural look to be maintained in the immediate area. She spoke about the enclave of rural uses that currently exist on Lavaca Trail and in the immediate area. Chairman Wall asked Ms. Gohr about the resale potential of her property because of the impact the size of this building has on her property. She responded that the area is clean and provides a wonderful service to the community and has no negative impact on her property, but only enhances the value of the neighborhood. Commissioner Kelly shared appreciation of the rural area of the neighborhood. Marty Gohr, 809 Lavaca Trail, spoke in favor of the special use permit. He said he is concerned about the higher density residential that is encroaching into this very special area of Coileyville. He said there are several nice properties in the area and they are diminishing because of the approval of recent higher density subdivisions like Westgate Villas. Mr. Gohr said the current use and the future intent by the Stajduhar's fit with the neighborhood. Andrew Mittag, 901 W. Lavaca Trail, spoke in favor of the special use permit. He said he has spoken before the commissioners on several occasions and they may have heard before how he moved from New York to Kansas and has now found the oasis in Colleyville on Lavaca Trail. He expressed the need to keep the area rural and how the frontage on Precinct Line will be developed as commercial, but the interior of the area needs to be maintained as rural. Mr. Mittag said he has three horses on his property and this structure does not bother him one bit. He said the Stajduhar's are an asset to the community. Planning & Zoning Commission Minutes - March 24, 2003 Page 5 of 8 Approved on Apri/14, 2003 Chairman Wall asked the Stajduhar's if the property is being used as a commercial venture. Mr. Stajduhar said no. He stated he operates a physical therapy clinic in Bedford, and his wife Lisa is certified to use horses as vehicles to help disabled people gain mobility. He said their family and the neighbors ride horses on the property and they have gate openings to the neighbor's property. There being no one else present wishing to speak, the public hearing was closed. Commissioner Swift told Mr. Stajduhar that he made a very good presentation and he now understands the request. He said the accessory building conforms to the area. Commissioner Sellers moved to approve the special use permit with a condition that the 10' x 10' rock building be removed in order to reduce the number of accessory buildings on the property. Commissioner Kelly seconded the motion. Commissioner Byerly said he does not have a problem with the motion but asked staff if they could put a provision in the ordinance that the removal of the building be given a deadline such as 45 days. Fire Marshal Jeff Jones said that technically a building of this size should have a fire sprinkler system. He said if the building is ever enclosed it would create a problem. Chairman Wall asked what other safety concerns the Fire Marshall had, especially if there were physically impaired people on the property. Jeff Jones responded that the building is all right if it is used as intended and as stated in the ordinance. He said if a building permit were ever applied for, they would reassess the use at that time. Chairman Wall expressed concerns about potential commercial uses on the property. Staff told the commissioners that commercial uses are not allowed unless authorized by the Land Development Code. Staff advised the use of the property is for riding horses, and the only issue the commissioners are considering is for the building proposed in the special use permit. Chairman Wall called for the vote. The vote being: Ayes: Kelly, Swift, Byerly, Sellers, Jones, Wall Noes: None 4. Case Z-03-008 - PUBLIC HEARING - Zoning Change from CC2 to PUD-R, 9.285 acres located on the south side of Centerpark, east of Colleyville Boulevard This item was tabled by the Commission earlier in the meeting. Planning & Zoning Commission Minutes - March 24, 2003 Page 6 of 8 Approved on Apri/14, 2003 5. Case Z-03-009 - PUBLIC HEARING - Amendment to the Land Development Code regarding notification requirements for Special Use Permits for alcoholic beverages Barry LeBaron presented the case to the commissioners and reviewed the staff briefing. There were questions by the commissioners regarding the current notice procedure and the proposed change. Commissioner Kelly said that if the 500-foot notification area was used, it might impede upscale restaurants from coming to Colleyville. He said there might be a red flag raised since no other communities in the area have this requirement. Chairman Wall opened the public hearing, and those present wishing to speak were: Jo Ann Gasper, 4103 Paddington Lane, spoke in opposition of the change in notification area. She said city staff does an excellent job of notification with the use of signs, notice to property owners, newspaper articles, and notice to homeowner associations. She said if they start with this exception, there might be other exceptions to follow. She said Colleyville needs to be on a level playing field with other communities in the area in order to attract businesses. She explained how the distance requirement was changed to comply with the State law in order to attract restaurants to Colleyville. Ms. Gasper encouraged the commissioners to recommend denial of the change. There being no one else present wishing to speak, the public hearing was closed. Commissioner Kelly moved to recommend denial of the change to the notification requirements for special use permits for alcoholic beverages. Commissioner Sellers seconded the motion. The vote being: Ayes: Kelly, Swift, Byerly, Sellers, Jones, Wall Noes: None 6. Discussion of the Master Plan Update. Appreciation to Barry LeBaron was expressed by the commissioners for all of his work that has been done. 7. Staff Comments, Reports and Discussion Items: None. 8. Commissioners' Comments and Reports: The commissioners asked for an update on the status of Bob Culley's request to be reinstated to the Planning and Zoning Commission. Staff informed them that Mr. Culley was asked to submit his application for appointment along with the others that would be considered by the City Council at the April 1 ,2003 meeting. He said advertisements for the opening had already taken place before Mr. Culley requested to be reinstated. Planning & Zoning Commission Minutes - March 24, 2003 Page 7 of 8 Approved on Apri/14, 2003 ADJOURNMENT The Commission moved to adjourn the meeting at 8:50 p.m. The motion was seconded and passed by acclamation. Respectfully Submitted, ~~ ~n~ing & Zoning Assistant Approved on: Note: As a matter of public record, an audio recording of this Planning and Zoning Commission meeting is available upon request. Planning & Zoning Commission Minutes - March 24, 2003 Page 8 of 8 Approved on Apri/14, 2003 cc.~ Texas PLANNING AND ZONING COMMISSION MEETING MINUTES - April 14, 2003 CALL TO ORDER Chairman Wall called the meeting to order at 7:00 p.m. ROLL CALL Commissioners Bruce Kelly, Earl Swift, Jeff Byerly, Mark Jones, and Jeff Wall were present. Commissioner Bud Sellers was absent. Barry LeBaron, Clayton Husband, Jeff Jones, and Jan Levy from staff were present. INVOCATION The invocation was given by Commissioner Swift PLEDGE OF ALLEGIANCE APPROVAL OF MINUTES March 24, 2003 Commissioner Byerly moved to approve the minutes as written. Commissioner Kelly seconded the motion. The motion passed by unanimous acclamation. SWEARING IN Bob Culley was sworn in at Place 5 CITIZEN COMMENTS There was none. AGENDA ITEMS 1. Case P-03-009 - Replat of Colleyville Shopping Village Addition, Lots 4R-2-1, 4R-2-2, 4R-2-3, and 4R-2-4 located at 6201 Colleyville Boulevard Clayton Husband presented the case to the commissioners. Barry LeBaron explained how commercial lots are not required to have frontage on a public street but are required to provide access from a dedicated access easement. He said these lots are accessible from a dedicated easement, which connects to both Colleyville Boulevard and Sanders Lane. Commissioner Culley moved to approve the minor plat. Commissioner Jones seconded the motion. The vote being: Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall Noes: None Planning & Zoning Commission Minutes - April 14, 2003 Page 1 of 8 Approved on April 28, 2003 2. Case Z-03-006 - TABLED ITEM - Zoning Change from CN to PUD-R, 2.05 acres located at the northeast corner of Cheek Sparger Road and Steeplechase Drive Commissioner Jones moved to remove the item from the table for discussion. Commissioner Swift seconded the motion. The vote being: Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall Noes: None Clayton Husband presented the case to the commissioners and reviewed the staff briefing. There was discussion by staff and the commissioners about the changes in the number of lots, the size of the lots, the density of the subdivision, and the plans to offer open space that will help in the realignment of Cheek Sparger Road. Mr. Husband distributed a larger size of the revised zoning exhibit that reflected the changes. He told the commissioners that a ten foot (10') wide trail is required along Cheek Sparger Road and the applicant has not asked for a waiver from the requirement. Chairman Wall moved to reopen the public hearing. Commissioner Swift seconded the motion. The motion passed by acclamation. Those present wishing to speak were: Jimmy Schnurr, applicant, told about how they took the issues that were problematic to the surrounding homeowners and redesigned the subdivision by reducing the number of lots, and adding some open space. He introduced the developer, Monte Thomason. Monte Thomason, developer, said he met with the Bridlewood Estates Homeowners Association and addressed the line of sight issue by placing open space along the southwestern portion of the subdivision. He said the proposed subdivision will have an entry feature that is compatible with Bridlewood Estates, they reduced the number of lots 20% from 10 lots to 8 and now offer approximately four dwelling units per acre. He said they redesigned the subdivision so that the smaller lots would abut the commercially zoned property to the east and the largest lots would abut the residential lots to the north. He said they now have a 45% reduction in paved area and they will limit the houses along Steeplechase and the two northern lots to one story and there will be three lots along the eastern side of the subdivision that will be allowed to have 1 % story homes. Mr. Thomason said they will exceed the Bridlewood deed restrictions and they will require 95% masonry coverage and no front-entry garages. He said there will be a HOA that will maintain all grass and landscaping and he plans on planting 15' to 17' live oak trees along Steeplechase to the west of the subdivision and they agree to the construction of a ten foot trail that is required along Cheek Sparger Road. He said they contacted Woodbriar Estates, The Woods of Colleyville, and the Saddlebrook homeowners associations to inform them of the proposed changes. Planning & Zoning Commission Minutes - April 14, 2003 Page 2 of 8 Approved on April 28, 2003 Commissioner Swift asked staff about the zoning and use of the lots to the east. There was discussion about the use of the property along Cheek Sparger. Commissioner Swift asked the fire marshal if he was all right with the reduction of paved area in the subdivision and Fire Marshal Jones responded that he did not have any problems with it and it is adequate for that length of street. Tom Caunitz, 4006 Steeplechase Drive, represented the Homeowners Association for Bridlewood Estates and said they met with the developer at the annual HOA meeting. He said they liked the changes and there are tremendous selling points. He said everyone at the meeting is in favor of a residential use for the property and the developer has worked with them to provide landscaping along Steeplechase. Pam Brandon, 3608 Briarwick Court, said she is president of the Woodbriar HOA and is in favor of the changes made by the developer. She said she spoke to four out of the six residents who live along Cheek Sparger Road as they would be most impacted by the development. She said they were in favor. D. J. Garmon, 3720 Oakbriar, said he was very concerned about traffic. He reported that people use Woodbriar Estates as a cut-through and they don't obey the speed limits or stop signs. He said he doesn't agree there would be more traffic generated by a commercial use than a residential development on the property. He said the density is still too high and Bridlewood Estates and the Woods at Colleyville were required to provide 20% open space. Steve Knight, 3917 Felps Court, spoke in opposition. He explained where he lived in relationship to the zoning change request. He said that density is a problem and sited the Sparger/Felps Addition as setting a trend in the area. He told the commissioners that Bridlewood's higher density was a result of the land being originally zoned multi-family and the desire of the citizens to have single family homes on the property rather than multi-family. He encouraged the commissioners to not keep scaling down the size of lots in Colleyville. He agreed that residential is the best use of the land, but still believes there is crunch room and the lots could be larger and fewer. There was no one else present to speak, and Chairman Wall closed the public hearing. Commissioner Jones moved to deny the zoning change as proposed. Commissioner Swift seconded the motion. There was discussion by the commissioners following the motion. Commissioner Culley said he agrees with the denial and the development needs more green belt and also density is an issue because the lots are significantly smaller than Bridlewood. Commissioner Byerly spoke about the need to jealously guard the adjoining commercial space and take a wait and see position in case commercial can develop in the area. Commissioner Kelly said even the representatives from Bridlewood supported reducing the density in order to have residential development on that property. Planning & Zoning Commission Minutes - April 14, 2003 Page 3 of 8 Approved on April 28, 2003 Chairman Wall called for the vote. The vote to deny being: Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall Noes: None Chairman Wall explained that the case can go to City Council for consideration; however it will require a super majority approval vote to grant the zoning change request. 3. Case Z-03-008 - PUBLIC HEARING & TABLED ITEM - Zoning Change from CC2 to PUD-R, 9.285 acres located on the south side of Centerpark, east of Colleyville Boulevard Clayton Husband presented the case to the commissioners and reviewed the staff briefing. He told the commissioners that the applicant and representative are in attendance to make a presentation. Clayton said staff received two letters of opposition and they are in the commissioners' packets. Commissioner Jones moved to remove the item from the table. Commissioner Kelly seconded the motion. The vote being: Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall Noes: None Kennis Ketchum, Portfolio Development, was present to represent the case. She spoke about the need for senior housing and presented statistics supporting her position. She said the buildings would have direct access garages and when they designed the architectural style, they were sensitive to what Colleyville is about and they didn't want to insult the community. Kennis said they will limit the buildings to one story where the buildings abut current residential and will and can legally restrict the rentals to seniors. She said the rents will be between $800 to $1,500 per month. Greg Faulkner, architect, also representing the land owner, showed slides of other similar projects that were developed in Dallas and other parts of the country. He explained the concept and how they try to keep the scale and luxury of single family homes and told about other amenities. Mr. Faulkner said there will be kitchen islands in some units and walk in closets. He said the streets will have names to give a sense of a single family development. He said there will be approximately 142 units and there will be entries off Centerpark and Colleyville Boulevard. He said that all cars will be required to be parked in garages; however they will provide guest parking. Commissioner Swift asked questions about the comparison of the proposed Colleyville project to the Hilton Head project that Mr. Faulkner's company designed. Mr. Faulkner said that the project was built in 1997 to 1998 and the projects would be similar in construction costs, but Planning & Zoning Commission Minutes - April 14, 2003 Page 4 of 8 Approved on April 28, 2003 the Hilton Head project would demand a higher rental cost, and the Hilton Head project was exclusively rentals. Commissioner Culley commented that the fronts of the buildings in the Colleyville design lack brick and masonry. Commissioner Jones questioned the marketing and research study that was performed and asked what brought the developer to Colleyville. Mr. Faulkner and Kennis Ketchum said that the owner has had no good commercial offers on the property and they felt there was a need to propose something different so that the property could be developed. There was discussion about why the developer is proposing rentals vs. sales. Mark Hiller, 6615 Brookshire, Dallas, Texas, owner of the property, said that Colleyville has a situation where parents are living with children and he felt there is a definite need for this kind of project for Colleyville residents. He said that he is not married to an apartment concept and would take the comments offered by the commissioners and consider condominiums. Commissioner Jones asked if the market study indicated that rents are more desirable than condominium ownership. Mr. Hiller responded that according to the economic part of the issue, rentals would be the first choice, but condominiums would not prohibit his interest in the development of the land. Andrew Wayne, 1009 Lakeridge, commented that the developer made a good presentation and said he is 57 years old and there is a need in Colleyville for senior citizen housing; however, the commissioners denial of the previous case because of density issues, negates approval of this item because it has an even higher density. He said there is a need for housing for seniors in Colleyville, but not a need for this type of living quarters. He said that this is not a marketing study provided by the applicant, but a professional study. He said there is very little greenbelt associated with the development and adding a minimum of 100 cars to Centerpark will affect all who live in the area. He said he is opposed to the zoning change. Dr. Susan Hess, 4609 Westbury Drive, said she lives in the Lakes of Somerset subdivision and has concerns that this development does not fit the ambiance of the area. She said density, and traffic concerns are a huge issue and there are better uses for the property. Don Shaver, 1001 Edgewater, said reports by City Council have stated that there are 57 seniors in Colleyville and he supposed those 57 seniors would not downsize to a two story apartment. He said nice garden homes with a lower density should be considered for the property. Ken Wallace, 4205 Green Meadow East, said he is in total opposition of the proposed zoning change. He said there should be no two story structures and has fears that in the future the property would not be maintained and it's value would decline. He said this may be a good concept, but not for where it is proposed. Larry Henry, 4104 Inwood Lane, said he is a 15 year Colleyville resident, and there is a need for more commercial tax producing businesses. He said this proposal is too disparate from the Planning & Zoning Commission Minutes - April 14, 2003 Page 5 of 8 Approved on April 28, 2003 Master Plan and the commissioners need to take time and understand the impact this proposal will have on the area. Margaret Sherlock, 905 Briar Ridge, said the City already has an apartment/town home project that was built by a Dallas developer who built two story buildings with the master bedroom upstairs and that was not a successful project. She spoke in opposition. Phil Charon, 4604 Clearwater Court, said his property abuts the east property line of the proposed project. He said that two story apartments are not designed for seniors. He said the developer has stated he proposes luxury apartments and when he compared rates along Highway 121, the average rental is $1.00 per square foot average. He said this proposed project is not a luxury apartment, but compares with average apartment rentals. He said that even though one story apartments are being proposed along the eastern property line, the finish floor elevations will rise to the west toward the flood plain and those buildings will overlook his property. He spoke about density and traffic problems and said this proposal is not suitable for Colleyville. Steve Ewing, 700 Green Meadow North, said he was on the Board of Directors of Saddlebrook HOA. He spoke in opposition due to density and the negative impact it would have on home values in the area. Ron Grove, 4708 Lakeshore Court, said there are so many boarded up businesses along Highway 26 and the addition of this type of project will degrade property values. Alan Jackson, 4801 Lakeshore Court, said most elderly people do not live in apartments. He said he pays three times the amount of taxes as in Keller, but does so willingly in order to live in a community that does not have these kinds of projects. He spoke about the negative impact the additional traffic and high density have and stated there is a place for this kind of product, but not here. Jim Gormley, 502 Green Meadow North, spoke in opposition sighting high density, lack of open areas and lack of green belts. He said Centerpark access is an issue as is the risk of seniors accessing off Colleyville Blvd. He said patio homes would be a great alternative with fewer units and one story buildings. Brad Trow, 4605 Colleyville Boulevard, said he owns the property where Riceland is located. He said although he relishes the idea of having so many hungry people nearby to support the restaurant trade, the property will become more desirable for commercial development when Highway 26 is widened. Kennis Ketchum, applicant, said that they appreciate all of the comments, and they are trying to come up with the highest and best use of the property. She said the owner has not been able to sell as commercial and they are proposing an alternative use. Chairman Wall closed the public hearing. Commissioner Culley commented that it appears the developer is here to make changes and work with the neighbors and he has never heard such productive comments at a public hearing Planning & Zoning Commission Minutes - April 14, 2003 Page 6 of 8 Approved on April 28, 2003 before. He said that Centerpark can handle more traffic and it can be regulated as the outgoing traffic from the day care center is regulated. He said that density is an important issue and apartments are not needed at this time in Colleyville. Commissioner Swift said that he is qualified to speak as a senior citizen. He spoke about current problems with a similar project, Spring Garden. He said that apartments don't fit the long term image of Colleyville and are counterproductive. He said he was very impressed with the image of Lakewood Estates and is sensitive to their comments. He said he did not believe it was legal to restrict rentals by age. Commissioner Kelly said that the comments by the citizens are not against development and growth in the area, but are against this type of proposal. He said it seemed as if the citizens and developer still want something to happen on the property. Commissioner Jones moved to deny the zoning change request. Commissioner Culley seconded the motion. The vote being: Ayes: Kelly, Culley, Swift, Byerly, Jones, Wall Noes: None Chairman Wall encouraged citizens to get involved with the Master Plan Update process. He said it seems as if the developer is willing to work with the community. [NOTE: The Planning and Zoning Commission took a 5 minute break and then resumed the meeting.] 4. Discussion of the Master Plan Update: Barry LeBaron said he is pleased with the positive feedback he has received regarding the meetings. He went over the upcoming schedule and outlined the process once the neighborhood meetings are concluded. Chairman Wall asked the commissioners to check their June and July schedules and notify staff so that meetings can be scheduled when most members can be present. There was discussion about comments raised in a Master Plan neighborhood meeting about the City pooling resources with the GCISD. Chairman Wall requested that staff meet with the new City Council and Mayor to update them on the Master Plan process with the Planning and Zoning Commission present. 5. Staff Comments, Reports and Discussion Items: There were none. Planning & Zoning Commission Minutes - April 14, 2003 Page 7 of 8 Approved on April 28, 2003 6. Commissioners' Comments and Reports: There were none. ADJOURNMENT The Commission moved to adjourn the meeting at 8:55 p.m. The motion was seconded and passed by acclamation. Respectfully Submitted, an Levy Planning & Zoning Assistant Approved on: April 28, 2003 as written. Note: As a matter of public record, an audio recording of this Planning and Zoning Commission meeting is available upon request. Planning & Zoning Commission Minutes - April 14, 2003 Page 8 of 8 Approved on April 28, 2003 COLLEYVILLE LIBRARY BOARD MINUTES March 10, 2003 I. CALL TO ORDER - The meeting of the Colleyville Library Board was called to order at 7:07 p.m. ROLL CALL - Members present: Chair Gary Taraba, Vice Chair Carol Wollin, Pat Jones, Richard Roxburgh, Susan Barzelay, Mary Alice Rippe, Mary Ann Nicholson and Nancy Eytcheson Ex-Officio Members present: Mayor Donna Arp Ex-Officio Members absent: Dr. Kevin Singer, Dr. Larry Darlage, Steve Jacobs, Ret Stansberger and Steve Banta. Council Liaisons present: Mayor Pro Tem Ginny Tigue. Staff present: Dianne McWethy, Mary Rodne and Cindy Martin. II. ANNOUNCEMENTS Chair Gary Taraba read Caren Handleman's letter of resignation into the record. Staff gave an overview of the process of filling the vacant position. III. INTRODUCTION OF LIBRARY DIRECTOR MARY RODNE Chair Gary Taraba welcomed Library Director Mary Rodne on behalf of the Board. IV. APPROVAL OF THE FEBRUARY 10, 2003 MINUTES - A motion was made by Pat Jones, seconded by Susan Barzelay to approve the February 10, 2003 minutes, as corrected. V. Development of Policies and Procedures a. Exhibits and Displays b. Confidentiality c. Bulletin Boards & Handouts d. Study Room Use e. Computer Use f. Other There was a general discussion regarding these policies. Director Mary Rodne will present policies at the next Board meeting. VI. DISCUSSION AND CONSIDERATION OF THE COLLEYVILLE ROTARY CLUB ANNUAL EVENT There was a general discussion regarding the event. The Board decided to refer the Rotary Club to the Friends of the Library and the Library Foundation for further discussion. VII. CITY HALL AND LIBRARY CONUSTRUCTION UPDATE Staff gave an overview of the City Hall and Library construction project. VIII. FRIENDS OF THE COLLEYVILLE PUBLIC LIBRARY UPDATE Carol Wollin President of the Friends of the Colleyville Public Library gave an update of the Friends of Library scheduled events and a grant the Friends received from Verizon. IX. COLLEYVILLE PUBLIC LIBRARY FOUNDATION UPDATE Mayor Pro Tem Ginny Tigue gave an overview of the Colleyville Public Library Foundation's activities. X. SUGGESTED ITEMS FOR FUTURE MEETINGS The Board requested that a tour of the Library construction site be added to the next agenda. XI. ADJOURN: A motion was made by Mary Ann Nicholson, seconded by Nancy Eytcheson to adjourn the meeting. Motion approved. The meeting of the Colleyville Library Board was adjourned at 8:25 p.m. COLLEYVILLE HISTORICAL PRESERVATION COMMITTEE Minutes - March 11,2003 I. Call To Order - The meeting of the Colleyville Historical Preservation Committee was called to order at 7:05 pm. Roll Call- Members present: Chairman Joe Deupree, Sammie Bolling, Lila Coley, Nicky Fettig, Ed Havran, and Shirley Schollmeyer. Members absent: Gerald Hartman, Jr., Molly Munson, Mike Patterson, and Betty Jean Willbanks. Also present were Deputy City Manager Dianne McWethy, Parks and Recreation Manager Monica Walsh, Mayor Pro Tern Ginny Tigue and Mayor Donna Arp. II. Approval of Minutes of February 11, 2003 - Ed Havran made a motion, second by Lila Coley, to approve the minutes of the meeting of February 11,2003. Motion approved. III. Presentation By Larry Crowder for Historical Public Art - Mr. Crowder, known for his bronze sculptures, presented to the Committee the following proposal for a bronze bust of Dr. Colley to be placed in front of City Hall: BUST - $8500.00 (113 WHEN COMMISSION IS GRANTED, 1/3 WHEN CLAY IS APPROVED, 1/3 ON DELIVERY) Price does not include pedestal. IV. Presentation by Brenda Mohle, Signet Art, Owner/Art Consultant, for Texas Bank Historical Photographs - Ms. Mohle discussed the Texas Bank project currently under construction on Colleyville Blvd. She stated that Texas Bank is the oldest, Texas owned bank and specializes in banks in small communities. She is requesting that the Committee help with the project of locating historical photographs that she can use for decorating the new Texas Bank. V. Discussion of Webb House National and State Historical Marker - Colleyville Parks and Recreation Manager Monica Walsh presented the Committee with information and guidelines required to apply for County, National and State Historical markers for the Webb House. Joe Deupree reported that the Grapevine Historical Society requested permission to have an outdoor meeting in the park at the Webb House in September. VI. Discussion and Consideration of Approval of Local Historical Marker Application for the Fire Station/City Hall - A motion was made by Lila Coley, second by Ed Havran, to approve and send to the City Council the application for a local historical marker to be placed at Texas Bank. Motion approved. VII. Update of Local Historical Marker Applications - Ed Havran reported that he has completed the research and is working on the application for a marker to be placed at the Bogart Dairy site located at Colleyville Blvd. and Hall Johnson Rd., currently the Town Center site. VIII. Update of Historical Preservation Foundation - Shirley Schollmeyer reported that she has been working with Administrative Assistant Cindy Martin and plans to have the required paperwork to present at the next meeting. IX. Discussion and Consideration of Historical Information for the Colleyville Website - No report XI. Discussion of City of Colleyville 50th Year Anniversary Event - No report Due to the lack of a quorum, the meeting was recessed at 9: 15 pm. XI. Adjourn - Meeting adjourned at 9: 15 pm. The next regular scheduled meeting will be April 8, 2003, at 7:00 pm. ZONING BOARD OF ADJUSTMENT MINUTES OF MEETING - MARCH 25, 2003 REGULAR MEETING: Chairman McNosky called the regularly scheduled meeting to order at 7:00 p.m. on March 25, 2003. Roll Call Present: Rich Munson, Skip Reynolds, Butch Bercher, Larry Henry, Dee McNosky, Ron Sturgeon, Pat Davis Staff: Tom Niederauer, Jan Levy, Eddie Edwards Approval of Minutes March 11, 2003 Butch Bercher moved to approve the minutes. Larry Henry seconded the motion. The motion was passed by a unanimous vote. Chairman McNosky explained the procedures of the Zoning Board of Adjustment and outlined the meeting format for the audience. She explained that approval of a variance requires four (out of five) affirmative votes by members of the Board. The five voting members were: Rich Munson, Skip Reynolds, Butch Bercher, Dee McNosky, and Larry Henry; however, the alternate members may enter into the full discussion of the case. AQenda Items Case A-03-003 - PUBLIC HEARING. Request by Larry Cole, Foxcreek Residential Development, I nc. for a variance from the fence setback regulations of the Colleyville Land Development Code at 401 Vintage Court, Lot 17, Block 5, Remington Park Addition, Phase III Tom Niederauer presented the case to the Board and reviewed the staff briefing. He displayed overheads of the location of the property, the site plan, and pictures of the property and surrounding areas. He said there was one letter of opposition included in their packets; however, three additional letters of opposition were received the afternoon of the meeting and copies of those letters have been made and distributed to the Board members and the applicant. There was a question about the location of the driveway on the adjacent lot at 6104 Remington Parkway. Staff informed the Board and showed a picture to indicate the driveway was located at the far end of the lot and was not immediately adjacent to the lot at 401 Vintage Court. Chairman McNosky opened the public hearing portion of the meeting. Those present wishing to speak were: Larry Cole, applicant, presented the case to the Board. He said he is the developer of Remington Park and also acts as the Chairman of the Architectural Control Board for the subdivision. He Zoning Board of Adjustment Minutes - March 25, 2003 Page 1 of 3 Approved on April 8, 2003 explained how this was a very unusually shaped lot that is impacted by having street setbacks on three sides and the owner, Peter Dibella, wanted to achieve some privacy in the back yard. He said seven of the eight board members on the Architectural Control Board viewed the plans and had no objections. He said they determined there would be no obstruction of view on the street and the aesthetics of the proposal was very important to the subdivision as a whole. He said the good side of the fence will face out and the Architectural Control Board agreed that they didn't want to look into the Dibellas' back yard. He said that Peter Dibella is a landscaper and what he will provide for landscaping will be very attractive and well maintained. Mr. Cole told the Zoning Board of Adjustment members that no neighbors spoke with him, as the developer of Remington Park, or the home owner, so they were surprised by the opposition and have not had time to talk with the neighbors who expressed opposition in writing, and did not attend the meeting to openly discuss their concerns. Pete Dibella, 401 Vintage Court, said there is a beautiful mature live oak tree on the lot closer to Vintage Court and they wanted to preserve the tree for the neighborhood. He said that is why they positioned their home as they did on the lot and they needed to build a home that is in the same style and size for the subdivision. He said they would like to build a pool off the patio as others have done in the neighborhood. Mr. Dibella said he will provide landscaping that benefits the neighborhood and he is open to adjusting the setback a little to provide for the landscaping. He said maintenance will not be a problem since he is in the business. Ron Sturgeon asked Mr. Dibella if he met with his neighbors, could a compromise be reached? Butch Bercher said there was a compromise offered in the packet with the possibility of using a wrought iron fence. Mr. Dibella said that privacy is an issue and the growth ofthe landscaping will not mature until three to four years to provide privacy. He said he has three children and it is very important to him that they have a fenced area to play in that is not visible from the street. Ron Sturgeon asked the applicant if he could split the difference from the setback he is asking for and the required setback and build the fence in that location. Larry Henry said there is possibility of the Board not granting a variance and before they get into negotiating a different setback for the fence, the Board needs to discuss the merits of the case. Larry Cole stated that originally he felt the less ground to be maintained outside the fence, the better it will be maintained. There was no one else present wishing to speak, and Chairman McNosky closed the public hearing portion of the meeting. Rich Munson said he drove around Remington Park and thought this was the only site where a solid fence would be adjacent to the sidewalk. He said the elevation of the street across from the fence, Chestnut Bend, would allow people coming off that street to have a clear view into the Dibellas' back yard. He said he saw another lot with a wrought iron fence around the pool, and he is not inclined to agree with a solid fence built in that area. Larry Henry said the Board needs to deal with the ordinances and constraints they are to work within. He said a wrought iron fence with shrubs as proposed by the letter writer does not present Zoning Board of Adjustment Minutes - March 25, 2003 Page 2 of 3 Approved on April 8, 2003 a good argument for the safety issue. He said when the shrubs fill in, there will be a solid barrier and that will be no difference than a wooden fence. Butch Bercher said the applicant did not receive the letters of opposition until just prior to the meeting and that puts the applicant and the board at a disadvantage because the neighbors did not appear at the meeting. Skip Reynolds said it is significant that the applicant has requested the Board to table the case, but the next time they appear before the Board he wants more information. He said he is troubled with the fencing issues because facing the house the way the applicant has, it disturbs the neighbors. He said there are three issues that are of importance and they are the safety issues, the aesthetics and property values of the neighborhood. He said there have been occasions and it is helpful if an applicant proposes a compromise plan such as a Plan A and a Plan B to the Board. He encouraged the applicant to look at other types of fences that would be appealing to the neighbors. Skip Reynolds moved to table the case until the April 8, 2003 meeting. Butch Bercher seconded the motion. Skip Reynolds amended his motion to include that the case may be tabled up to thirty days if necessary and the applicant will contact the City staff and advise them of the status of the request. Rich Munson seconded the amendment. The vote being: Ayes: Munson, Reynolds, Bercher, Henry, McNosky Noes: None ADJOURNMENT The meeting was adjourned by acclamation. They're being no further business, the meeting adjourned at 8:00 p.m. Respectfully Submitted, Jan Levy, Planning & Zoning Assistant Approved on: April 8, 2003 as written. Zoning Board of Adjustment Minutes - March 25, 2003 Page 3 of 3 Approved on April 8, 2003 RESOLUTION R-03-2146 A RESOLUTION APPROVING COUNCIL ACTION UNDER BUSINESS AT THE REGULAR COUNCIL MEETING OF MAY 6, 2003 WHEREAS, Council has taken action on certain items on the agenda under Business. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF COLLEYVILLE, TEXAS: Sec. 1. THAT the agenda decisions approved by Council action under Business this date and not otherwise adopted by Ordinance and/or separate Resolution as follows are hereby adopted: a. THAT AND IT IS SO RESOLVED. APPROVED THIS DAY OF _ AYES, NAYS AND ABSTENTIONS. 2003, BY A VOTE OF ATTEST: CITY OF COLLEYVILLE: Cynthia Singleton, TRMC City Secretary Mayor