HomeMy WebLinkAboutPlanning and Zoning Commission-Worksession-Agenda Packets-10/26/2026
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING
COMMISSION WORKSESSION
AGENDA
100 Main Street, Colleyville, Texas, 76034
MONDAY, OCTOBER 26, 2026 EXECUTIVE CONFERENCE ROOM - THIRD FLOOR
6:15 P.M.
1. CALL TO ORDER
2. PRESENTATION AND DISCUSSION
2a Presentation and discussion of a replat, with a waiver for lot area, for
proposed Lot 16R, Block 1, Wescoat Place, zoned R-40 Single-Family
Residential, located at 6108 Westcoat Drive, Case PC26-014
2b Presentation and discussion of a replat for proposed Lots 4R and 5R,
Block 1, Glenhope Addition, zoned R-20 Single-Family Residential,
located at 6616 Glenhope Circle North, Case PC26-016
2c Presentation and discussion of a rezoning from R-20 Single-Family
Residential to R-30 Single-Family Residential on Lot 1, Block 4, Western
Trails – Colleyville, located at 504 Bandit Trail, Case ZC26-031
2d Presentation and discussion of a Special Use Permit for an accessory
building on Lot 3, Block 4, Windview Addition, zoned PUD-R Planned
Unit Development – Residential, located at 2204 Woodstock Drive,
Case ZC26-032
2e Presentation and discussion of a rezoning to PUD-C Planned Unit
Development – Commercial on Lot 1R, Block 1, The Gardens and Tract
3G, Abstract 963, Absalom J. Lott Survey, zoned PUD-C Planned Unit
Development – Commercial, located at 7009 and 7015 Colleyville
Boulevard, Case ZC26-029 TABLED FROM THE OCTOBER 12, 2026,
PLANNING AND ZONING COMMISSION MEETING
2f Presentation and discussion of a rezoning from CC-2 Shopping Center
and ML Light Manufacturing to PUD-C Planned Unit Development –
Commercial on Tracts 3A01, 3A, and 4, Abstract 963, Absalom J. Lott
Survey, located at 6930/6900 Colleyville Boulevard and 1701 John
McCain Road, Case ZC26-033
2g Presentation and discussion of a Special Use Permit for a fence on Lots
26 and 27, Block 1, Colleyville Estates, zoned R-10 Single-Family
Residential, located at 812 Colleyville Terrace, Case ZC26-034
Planning and Zoning Commission Worksession
Agenda
October 26, 2026
City of Colleyville Page 2
3. ADJOURNMENT
I hereby certify this agenda was posted on City Hall bulletin boards Tuesday, October 20,
2026, by 5:00 p.m.
Daniel Ponder
Planning Manager
A quorum of any Colleyville board, commission, or committee may be present at this
meeting. Any matter on this agenda may, at the discretion of the governing body, be
opened for public comment and discussion.
If you plan to attend this public meeting and have a disability that requires special
accommodations, please advise the City Secretary at least 48 hours in advance at
817.503.1133, and reasonable accommodations will be made to assist you.
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number - Agenda Date 10/26/2026
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a replat, with a waiver for lot area, for proposed Lot 16R,
Block 1, Wescoat Place, zoned R-40 Single-Family Residential, located at 6108 Westcoat
Drive, Case PC26-014
Explanation
Stephen Zimmerer, the applicant, has submitted a request for a replat, with a waiver for
lot area, for proposed Lot 16R, Block 1, Wescoat Place, being approximately 0.68 acres
and zoned R-40 Single-Family Residential. The request is to create one platted lot that
does not meet the minimum area requirements for the R-40 zoning district.
Attachments
1. Aerial Map
2. Future Land Use Map
3. Zoning Map
4. Plat Exhibit
6008
6004
6000
5908
5904
201
6209
6207
6205
6208
6206
6204
6205
6201
6113 6200
61046105
61086101
6013
5919
5917
5913
6008
6002
6000
5905
5909
5916
6004
6008
209205
201
6001
6109
6105
6101
6015
6009
6003
6108
6100
6100
6114
6112
6108
6120
BETTINGER DRWESTCOAT DRK
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC26-014
6108 Westcoat Drive
Aerial Map
6008
6004
6000
5908
5904
201
6209
6207
6205
6208
6206
6204
6205
6201
6113 6200
61046105
61086101
6013
5919
5917
5913
6008
6002
6000
5905
5909
5916
6004
6008
209205
201
6001
6109
6105
6101
6015
6009
6003
6108
6100
6100
6114
6112
6108
6120
BETTINGER DRWESTCOAT DRK
Residential
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC26-014
6108 Westcoat Drive
Future Land Use Map
6008
6004
6000
5908
5904
201
6209
6207
6205
6208
6206
6204
6205
6201
6113 6200
6104
6105
61086101
6013
5919
5917
5913
6008
6002
6000
5905
5909
5916
6004
6008
209205
201
6001
6109
6105
6101
6015
6009
6003
6108
6100
6100
6114
6112
6108
6120
BETTINGER DRWESTCOAT DRR-20
R-30
AG
R-30 R-20R-40
R-40
R-30
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC26-014
6108 Westcoat Drive
Zoning Map
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number - Agenda Date 10/26/2026
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a replat for proposed Lots 4R and 5R, Block 1, Glenhope
Addition, zoned R-20 Single-Family Residential, located at 6616 Glenhope Circle North,
Case PC26-016
Explanation
Ganiat Mumuney, the applicant, has submitted a request for a replat for proposed Lots
4R and 5R, Block 1, Glenhope Addition, being approximately 1 acre and zoned R-20
Single-Family Residential. The request is to create two lots.
Attachments
1. Aerial Map
2. Future Land Use Map
3. Zoning Map
4. Plat Exhibit
6600
6604 6608 6612 6616
6605 6609 6613
650165056509
6512 6508 6504 6500
26062604260226002508250625042502
26072605260326012509250725052503
69002417
POOL RDG L E N H O P E C I R S
TWELVE OAKS LN
G L E N H O P E C I R N
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC26-016
6616 Glenhope Circle N
Aerial Map
6600
6604 6608 6612 6616
6605 6609 6613
650165056509
6512 6508 6504 6500
26062604260226002508250625042502
26072605260326012509250725052503
69002417
POOL RDG L E N H O P E C I R S
TWELVE OAKS LN
G L E N H O P E C I R N
K
Residential
Institutional
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC26-016
6616 Glenhope Circle N
Future Land Use Map
6600
6604 6608 6612
6616
6605 6609 6613
650165056509
6512 6508 6504 6500
26062604260226002508250625042502
26072605260326012509250725052503
69002417
POOL RDG L E N H O P E C I R S
TWELVE OAKS LN
G L E N H O P E C I R N
AG
R-40
R-20
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC26-016
6616 Glenhope Circle N
Zoning Map
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number - Agenda Date 10/26/2026
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a rezoning from R-20 Single-Family Residential to R-30
Single-Family Residential on Lot 1, Block 4, Western Trails – Colleyville, located at 504
Bandit Trail, Case ZC26-031
Explanation
Wendy and Timothy Kelso, the applicants, have submitted a request for a rezoning from
R-20 Single-Family Residential to R-30 Single-Family Residential on Lot 1, Block 4,
Western Trails – Colleyville, being approximately 0.77 acres.
Attachments
1. Aerial Map
2. Future Land Use Map
3. Zoning Map
4. Statement of Planning Objectives
5. Zoning Exhibit
304
311
313
7401
7208
7300
7304
7308
7312
7209
7213
7217
7205
517
7209
72137212
7208
7209
7213
513 509 505 7216
7212
7208
7208
7416
7212
7216
7300
7304
7400
7404
7408
7412
504
5045085127405
7409 513 509 505 501
508510512
7401 513 509 505 501
500
7300
7304
7312
7400
7416
7301
7409
7303
BANDIT TROVERLAND TRCHISOLM CT
WINDSWEPT TRWINDSWEPT TRK
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-031
504 Bandit Trail
Aerial Map
304
311
313
7401
7208
7300
7304
7308
7312
7209
7213
7217
7205
517
7209
72137212
7208
7209
7213
513 509 505 7216
7212
7208
7208
7416
7212
7216
7300
7304
7400
7404
7408
7412
504
5045085127405
7409 513 509 505 501
508510512
7401 513 509 505 501
500
7300
7304
7312
7400
7416
7301
7409
7303
BANDIT TROVERLAND TRCHISOLM CT
WINDSWEPT TRWINDSWEPT TRK
Residential
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-031
504 Bandit Trail
Future Land Use Map
304
311
313
7401
7208
7300
7304
7308
7312
7209
7213
7217
7205
517
7209
72137212
7208
7209
7213
513 509 505 7216
7212
7208
7208
7416
7212
7216
7300
7304
7400
7404
7408
7412
504
5045085127405
7409 513 509 505 501
508510512
7401 513 509 505 501
500
7300
7304
7312
7400
7416
7301
7409
7303
BANDIT TROVERLAND TRCHISOLM CT
WINDSWEPT TRWINDSWEPT TRR-40
R-20
R-20
R-20
R-20
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-031
504 Bandit Trail
Zoning Map
Kelso – 504 Bandit Trail
Property conforms to requirements to R30. Wendy and I had previously asked “when” our
property was re-platted from R30 to R20 (without response) previously to the planning and
zoning committee. This was also asked in open meeting minutes during Planning and
Zoning when the property at the corner of Bandit and Overland Trail replat occurred.
We request your sincere consideration of our request and as always, will work openly and
collaboratively with the city and our neighbors for any future plans for the property.
Lot size for 504 Bandit is (per TAD): 33,628 square feet
Front/Street ROW Side (feet): 35 feet on Survey
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number - Agenda Date 10/26/2026
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a Special Use Permit for an accessory building on Lot 3,
Block 4, Windview Addition, zoned PUD-R Planned Unit Development – Residential,
located at 2204 Woodstock Drive, Case ZC26-032
Explanation
Michael Hershenberg, the applicant, has submitted a request for a Special Use Permit for
an accessory building on Lot 3, Block 4, Windview Addition, being approximately 0.27
acres, and zoned PUD-R Planned Unit Development – Residential. The request is to
reduce the side setback from 10 feet to 5 feet and the rear setback from 25 feet to 15
feet. Accessory buildings located within 10 feet of the primary structure must comply
with the zoning district setback requirements, per Land Development Code Section
3.27(3)(d).
Attachments
1. Aerial Map
2. Future Land Use Map
3. Zoning Map
4. Site Plan
5. Statement of Planning Objectives
2103 2105 2107 2201 2203 2205 2207 2209
2210
4001
4003
2107
4004
4000
3914
3912
3910
2208
3908 3906 3904
220422022200
3909
3911
3913
3915
3907
3916
3914
3912
3910
3908
3906
3909
3911
3913
4008
4000
3907
3911
3913
4001
4003
4010
4008 4006
3903
3901
3907
3911
4005
2325
TAMBLEWOODDRWOODSTOCK DR
RAMSGATE CT
AMBLESIDEDRWINDVIEW DR
CHEEK SPARGER RDSTONEHAVEN DR
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-032
2204 Woodstock Drive
Aerial Map
2103 2105 2107 2201 2203 2205 2207 2209
2210
4001
4003
2107
4004
4000
3914
3912
3910
2208
3908 3906 3904
220422022200
3909
3911
3913
3915
3907
3916
3914
3912
3910
3908
3906
3909
3911
3913
4008
4000
3907
3911
3913
4001
4003
4010
4008 4006
3903
3901
3907
3911
4005
2325
TAMBLEWOODDRWOODSTOCK DR
RAMSGATE CT
AMBLESIDEDRWINDVIEW DR
CHEEK SPARGER RDSTONEHAVEN DR
K
Residential
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-032
2204 Woodstock Drive
Future Land Use Map
2103 2105 2107 2201 2203 2205 2207 2209
2210
4001
4003
2107
4004
4000
3914
3912
3910
2208
3908 3906 3904
220422022200
3909
3911
3913
3915
3907
3916
3914
3912
3910
3908
3906
3909
3911
3913
4008
4000
3907
3911
3913
4001
4003
4010
4008 4006
3903
3901
3907
3911
4005
2325
TAMBLEWOODDRWOODSTOCK DR
RAMSGATE CT
AMBLESIDEDRWINDVIEW DR
CHEEK SPARGER RDSTONEHAVEN DR
AG
PUD-R
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-032
2204 Woodstock Drive
Zoning Map
LOT SIZE 11,875 SQ FT
LOT COVERAGE 29.3 %
SQUARE FOOTAGE
REFERENCE MAP
EXISTING RESIDENCE COVERAGE 2,570 SQ FT
PROPOSED GARAGE 718 SQ FT
TOTAL COVERAGE 3,474 SQ FT
DOCUMENT INDEX
SHEET 1 A-001 SITE PLAN
SHEET 2 A-101 FLOOR PLAN AND ELEVATIONS
SHEET 3 S-001 ROOF PLAN
SHEET 4 S-002 CEILING FRAME
SHEET 5 S-003 FOUNDATION PLAN
SHEET 6 S-004 WALL BRACING
SHEET 7 E-001 ELECTRICAL PLAN
THE FOLLOWING CODES HAVE BEEN ADOPTED BY THE
CITY OF COLLEYVILLE, TX:
INTERNATIONAL BUILDING CODE 2024
INTERNATIONAL RESIDENTIAL CODE 2024
INTERNATIONAL ENERGY CONSERVATION CODE 2024
INTERNATIONAL MECHANICAL CODE 2024
INTERNATIONAL PLUMBING CODE 2024
NATIONAL ELECTRIC CODE 2023FENCEFENCEFENCEFENCEEXG.
POOL
EXG.
2 STORY BRICK
RESIDENCE
PROPOSED
DETACHED GARAGE
2201 WOODSTOCK DRIVE
SIDEWALK
CONCRETE
DRIVEWAY
CONCRETE
PAVING
RETAINING WALLRETAINING WALL95.0' PROPERTY LINE
95.0' PROPERTY LINE
125.0' PROPERTY LINE125.0' PROPERTY LINELAWN LAWN
LAWN
10' SIDE SETBACK10' SIDE SETBACK30' B.L.
6.0' UTILITY EASEMENT
15.0' REAR SETBACK
LOT 12
LOT 2
LOT 4
LOT 20
(50.0' ROW)
5'-0"15'-0"3'-0"87'-4"57'-4"LOT 21
SITE PLAN
SCALE: 1 TO 20
18X24 TEMPLATE SCALE:DATE:PROJECT:SCOPE OF WORK:THIS SET OF PLANS HAS BEEN DEVELOPED IN ACCORDANCE WITH THE APPLICABLE CODES AND ZONING REGULATIONS OF THE JURISDICTION IN WHICH THE PROJECT IS SUBMITTED FOR REVIEW.THE DRAWINGS WERE PREPARED BASED ON INFORMATION PROVIDED BY THE OWNER AND WERE MADE AVAILABLE FOR THEIR REVIEW PRIOR TO SUBMISSION. THE OWNER AND/OR THEIR SELECTEDCONTRACTOR HAD SUFFICIENT TIME AND OPPORTUNITY TO REVIEW THE DOCUMENTS AND PROPOSE ANY NECESSARY REVISIONS. THE STRUCTURAL PLANS WERE REVIEWED AND STAMPED BY ALICENSED STRUCTURAL ENGINEER IN THE STATE OF TEXAS. THE PLAN PREPARER IS NOT RESPONSIBLE FOR CURRENT OR FUTURE STRUCTURAL DETAILS. ANY SIGNIFICANT STRUCTURAL CHANGESDURING CONSTRUCTION MUST BE COMMUNICATED AND APPROVED PRIOR TO EXECUTION. THE PLAN PREPARER ASSUMES NO RESPONSIBILITY FOR ERRORS, OMISSIONS, OR DEFICIENCIES THAT MAYOCCUR DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE APPROPRIATE MATERIALS, CONSTRUCTION METHODS, AND LABOR USEDTHROUGHOUT THE EXECUTION OF THE PROJECT. THE PLAN PREPARER IS NOT INVOLVED IN THE CONSTRUCTION PHASE. THE OWNER AND/OR CONTRACTOR MAY MODIFY THE MEP (MECHANICAL,ELECTRICAL, AND PLUMBING) DESIGN AS NEEDED TO ADDRESS ON-SITE CONDITIONS OR PROJECT REQUIREMENTS. THE CLIENT IS GRANTED THE RIGHT TO USE THESE PLANS FOR A ONE-TIMEPROJECT ONLY. REPRODUCTION, REDISTRIBUTION, OR USE OF THESE PLANS FOR MULTIPLE PROJECTS WITHOUT THE PLAN PREPARER'S WRITTEN CONSENT IS STRICTLY PROHIBITED.PAGE:SHEET:DETACHED GARAGE2204 WOODSTOCK DRCOLLEYVILLE, TX 760341 TO 2010/09/2026A-0011 OF 7
21'-2"20'-6"22'-8"
2 CAR GARAGE
9'-0" CLG. H.19'-0"D-1
5 12"9'-0"22'-5"BRICK
COMPOSITION SHINGLES
ROOFING
BRICK
1'-0"2'-0"12
11
12
11
LP SMART SIDING 9'-0"21'-512"FRONT ELEVATION
BRICK 1'-0"2'-0"12
11
REAR ELEVATION 9'-0"21'-512"BRICK 2'-0"1'-0"12
11
9'-0"22'-5"BRICK
BRICK
1'-0"2'-0"COMPOSITION SHINGLES
ROOFING
LP SMART SIDING
FAKE 24x36 IN WINDOW
12
11
12
11
18X24 TEMPLATE SCALE:DATE:PROJECT:SCOPE OF WORK:THIS SET OF PLANS HAS BEEN DEVELOPED IN ACCORDANCE WITH THE APPLICABLE CODES AND ZONING REGULATIONS OF THE JURISDICTION IN WHICH THE PROJECT IS SUBMITTED FOR REVIEW.THE DRAWINGS WERE PREPARED BASED ON INFORMATION PROVIDED BY THE OWNER AND WERE MADE AVAILABLE FOR THEIR REVIEW PRIOR TO SUBMISSION. THE OWNER AND/OR THEIR SELECTEDCONTRACTOR HAD SUFFICIENT TIME AND OPPORTUNITY TO REVIEW THE DOCUMENTS AND PROPOSE ANY NECESSARY REVISIONS. THE STRUCTURAL PLANS WERE REVIEWED AND STAMPED BY ALICENSED STRUCTURAL ENGINEER IN THE STATE OF TEXAS. THE PLAN PREPARER IS NOT RESPONSIBLE FOR CURRENT OR FUTURE STRUCTURAL DETAILS. ANY SIGNIFICANT STRUCTURAL CHANGESDURING CONSTRUCTION MUST BE COMMUNICATED AND APPROVED PRIOR TO EXECUTION. THE PLAN PREPARER ASSUMES NO RESPONSIBILITY FOR ERRORS, OMISSIONS, OR DEFICIENCIES THAT MAYOCCUR DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE APPROPRIATE MATERIALS, CONSTRUCTION METHODS, AND LABOR USEDTHROUGHOUT THE EXECUTION OF THE PROJECT. THE PLAN PREPARER IS NOT INVOLVED IN THE CONSTRUCTION PHASE. THE OWNER AND/OR CONTRACTOR MAY MODIFY THE MEP (MECHANICAL,ELECTRICAL, AND PLUMBING) DESIGN AS NEEDED TO ADDRESS ON-SITE CONDITIONS OR PROJECT REQUIREMENTS. THE CLIENT IS GRANTED THE RIGHT TO USE THESE PLANS FOR A ONE-TIMEPROJECT ONLY. REPRODUCTION, REDISTRIBUTION, OR USE OF THESE PLANS FOR MULTIPLE PROJECTS WITHOUT THE PLAN PREPARER'S WRITTEN CONSENT IS STRICTLY PROHIBITED.PAGE:SHEET:DETACHED GARAGE2204 WOODSTOCK DRCOLLEYVILLE, TX 760341/4" = 1'-0"10/09/2026A-1012 OF 7FLOOR PLAN
SCALE: 1/4" = 1-0"
FRONT ELEVATION
SCALE: 3/16" = 1-0"
REAR ELEVATION
SCALE: 3/16" = 1-0"
RIGHT ELEVATION
SCALE: 3/16" = 1-0"
LEFT ELEVATION
SCALE: 3/16" = 1-0"
11:1211:121'-0" TYP
UNDERLAYMENT
DRIP EDGE
START 3RD COURSE
WITH 10" REMOVED
STARD 2ND COURSE
WITH 5" REMOVED
STARD 1ST COURSE
WITH FULL SHINGLE
SHINGLES OVERHANG
DRIP EDGE 14" - 34"
STARTER STRIP
DRIP EDGE
DECK
SHINGLES ROOFING
not to scale
2x8 #2 RIDGE RAFTER2X6 #2 RAFTER @ 24" O.C.2X6 #2 RAFTER @ 24" O.C.TO RAFTERS
2X- CEILING JOIST PARALLEL
2x6 D.F.#2 RAFTER
2X4 D.F.#2 COLLAR TIE (COLLAR BEAM)
(LOCATED IN UPPER THIRD OF
ATTIC SPACE) (see 3.2.5.1)
2X8 D.F.#2 RIDGE BOARD
TYP RIDGE BOARD AND CEILING JOIST DETAIL
STRONGBACK
BRACE
18X24 TEMPLATE SCALE:DATE:PROJECT:SCOPE OF WORK:THIS SET OF PLANS HAS BEEN DEVELOPED IN ACCORDANCE WITH THE APPLICABLE CODES AND ZONING REGULATIONS OF THE JURISDICTION IN WHICH THE PROJECT IS SUBMITTED FOR REVIEW.THE DRAWINGS WERE PREPARED BASED ON INFORMATION PROVIDED BY THE OWNER AND WERE MADE AVAILABLE FOR THEIR REVIEW PRIOR TO SUBMISSION. THE OWNER AND/OR THEIR SELECTEDCONTRACTOR HAD SUFFICIENT TIME AND OPPORTUNITY TO REVIEW THE DOCUMENTS AND PROPOSE ANY NECESSARY REVISIONS. THE STRUCTURAL PLANS WERE REVIEWED AND STAMPED BY ALICENSED STRUCTURAL ENGINEER IN THE STATE OF TEXAS. THE PLAN PREPARER IS NOT RESPONSIBLE FOR CURRENT OR FUTURE STRUCTURAL DETAILS. ANY SIGNIFICANT STRUCTURAL CHANGESDURING CONSTRUCTION MUST BE COMMUNICATED AND APPROVED PRIOR TO EXECUTION. THE PLAN PREPARER ASSUMES NO RESPONSIBILITY FOR ERRORS, OMISSIONS, OR DEFICIENCIES THAT MAYOCCUR DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE APPROPRIATE MATERIALS, CONSTRUCTION METHODS, AND LABOR USEDTHROUGHOUT THE EXECUTION OF THE PROJECT. THE PLAN PREPARER IS NOT INVOLVED IN THE CONSTRUCTION PHASE. THE OWNER AND/OR CONTRACTOR MAY MODIFY THE MEP (MECHANICAL,ELECTRICAL, AND PLUMBING) DESIGN AS NEEDED TO ADDRESS ON-SITE CONDITIONS OR PROJECT REQUIREMENTS. THE CLIENT IS GRANTED THE RIGHT TO USE THESE PLANS FOR A ONE-TIMEPROJECT ONLY. REPRODUCTION, REDISTRIBUTION, OR USE OF THESE PLANS FOR MULTIPLE PROJECTS WITHOUT THE PLAN PREPARER'S WRITTEN CONSENT IS STRICTLY PROHIBITED.PAGE:SHEET:DETACHED GARAGE2204 WOODSTOCK DRCOLLEYVILLE, TX 760341/4" = 1'-0"10/09/2026S-0013 OF 7ROOF PLAN
SCALE: 1/4" = 1-0"
ROOF FRAME
SCALE: 1/4" = 1-0"
2X12 #2 C.J. @ 16" O.C.
9'-0" CLG. H.19'-7"21'-11"912"912"18'-0"2868
(2) 1.75 x 14 LVL BEAM2'-0 12"
UNINHABITABLE ATTIC, LIVE LOAD 10psf WITHOUT STORAGE
IRC 2024 TABLE R802.5(1)
SPACING
12"
16"
19.2"
24"
SPACING
12"
16"
19.2"
24"
SPECIE AND GRADE
DOUGLAS FIR #2
DOUGLAS FIR #2
DOUGLAS FIR #2
DOUGLAS FIR #2
SPECIE AND GRADE
SOUTHERN PINE
2X6
19-6
17-8
16-8
15-0
2X6
18-8
16-11
15-7
13-11
if douglas fir wood is suplied, same size members may be used.
dead load = 5 psf
CEILING JOISTS
MAX SPANS
2X8
25-8
23-4
21-4
19-1
2X8
24-7
21-7
19-8
17-7
2X10
note a
note a
26-0
23-3
2X10
note a
25-7
23-5
20-11
proposed framing is based on southern pine wood, based on lower resistance than douglas fir
AND IS most commonly use and availability;
SOUTHERN PINE
SOUTHERN PINE
SOUTHERN PINE
TYPICAL WALL FRAME
TRIMMER STUD
16" MAX. BETWEEN
CRIPPLE STUDS
2-2"X8" HEADER
CRIPPLE STUDS
2" X 8" HEADER
2-2"X4"T.P.
2"X4"SILL PLATE
2"X4" STUDS @ 16" O.C.
SEE FRAMING PLAN FOR BEAM / LVL LOCATIONS AND SIZES.
18X24 TEMPLATE SCALE:DATE:PROJECT:SCOPE OF WORK:THIS SET OF PLANS HAS BEEN DEVELOPED IN ACCORDANCE WITH THE APPLICABLE CODES AND ZONING REGULATIONS OF THE JURISDICTION IN WHICH THE PROJECT IS SUBMITTED FOR REVIEW.THE DRAWINGS WERE PREPARED BASED ON INFORMATION PROVIDED BY THE OWNER AND WERE MADE AVAILABLE FOR THEIR REVIEW PRIOR TO SUBMISSION. THE OWNER AND/OR THEIR SELECTEDCONTRACTOR HAD SUFFICIENT TIME AND OPPORTUNITY TO REVIEW THE DOCUMENTS AND PROPOSE ANY NECESSARY REVISIONS. THE STRUCTURAL PLANS WERE REVIEWED AND STAMPED BY ALICENSED STRUCTURAL ENGINEER IN THE STATE OF TEXAS. THE PLAN PREPARER IS NOT RESPONSIBLE FOR CURRENT OR FUTURE STRUCTURAL DETAILS. ANY SIGNIFICANT STRUCTURAL CHANGESDURING CONSTRUCTION MUST BE COMMUNICATED AND APPROVED PRIOR TO EXECUTION. THE PLAN PREPARER ASSUMES NO RESPONSIBILITY FOR ERRORS, OMISSIONS, OR DEFICIENCIES THAT MAYOCCUR DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE APPROPRIATE MATERIALS, CONSTRUCTION METHODS, AND LABOR USEDTHROUGHOUT THE EXECUTION OF THE PROJECT. THE PLAN PREPARER IS NOT INVOLVED IN THE CONSTRUCTION PHASE. THE OWNER AND/OR CONTRACTOR MAY MODIFY THE MEP (MECHANICAL,ELECTRICAL, AND PLUMBING) DESIGN AS NEEDED TO ADDRESS ON-SITE CONDITIONS OR PROJECT REQUIREMENTS. THE CLIENT IS GRANTED THE RIGHT TO USE THESE PLANS FOR A ONE-TIMEPROJECT ONLY. REPRODUCTION, REDISTRIBUTION, OR USE OF THESE PLANS FOR MULTIPLE PROJECTS WITHOUT THE PLAN PREPARER'S WRITTEN CONSENT IS STRICTLY PROHIBITED.PAGE:SHEET:DETACHED GARAGE2204 WOODSTOCK DRCOLLEYVILLE, TX 760343/16" = 1'-0"10/09/2026S-0024 OF 7CEILING FRAME
SCALE: 3/16" = 1-0"
11'-4"11'-4"
22'-8"1'-3"0"1'-3"S-1 S-1
S-1 S-1S-2S-2S-2 S-2
5" 3000 PSI CONC. SLAB/W
#3 BAR'S AT 16" O.C.E.W.
OVER 6 MIL
POLYVAPOR BARRIER
S-3
20'-6"10'-3"10'-3"18'-0"S-1S-11'-6"10"
GRANULLAR FILL
#3 REBAR @ 16" O.C.E.W.
COMPACTED GROUND
3500 PSI CONCRETE
#3 STIRRUPS @ 36" O.C.
#5 REBAR @ TOP
#5 REBAR @ BOTTOM5"3"3"1 12"
S-2 INTERMEDIATE BEAM
SCALE: 3/4" = 1'-0"
6 MIL VAPOR BARRIER 2'-0"6"3"2"5"GRANULLAR FILL
#3 REBAR @ 16" O.C.E.W.
COMPACTED GROUND
3500 PSI CONCRETE
#3 STIRRUPS @ 36" O.C.
6 MIL VAPOR BARRIER
#5 REBAR @ TOP
#5 REBAR @ BOTTOM
F.F.L.
S-1 EXTERIOR BEAM
SCALE: 3/4" = 1'-0"6"6"1'-0"
1 12"
12" ANCHOR BOLTS @ 6' O.C. MAX
2X4 WALL STUDS
BRICK FINISH
WALL BRACING
2'-0"6"3"2"5"GRANULLAR FILL
#3 REBAR @ 16" O.C.E.W.
COMPACTED GROUND
3500 PSI CONCRETE
#3 STIRRUPS @ 36" O.C.
6 MIL VAPOR BARRIER
#5 REBAR @ TOP
#5 REBAR @ BOTTOM
S-3 EXTERIOR BEAM
SCALE: 3/4" = 1'-0"6"1'-0"
1 12"
12" ANCHOR BOLTS @ 6' O.C. MAX
2X4 WALL STUDS
BRICK FINISH
WALL BRACING
S-1
S-2
ID
12 X 24
10 X 18
SECTION
2 #5
REINF @ TOP
-
REINF @ MIDDLE
2 #5
REINF @ BOTTOM
2 #5 2 #5
#3 @ 36" O.C.
STIRRUPS
#3 @ 36" O.C.
EXTERIOR
DESCRIPTION
INTERMEDIATE-
S-3 12 X 24 2 #5 -2 #5 #3 @ 36" O.C.EXTERIOR
CONCRETE NOTES:
1. Concrete Specifications:
- Concrete for slab and beams to be 3500 psi at 28 days.
- All concrete to be free of voids, honeycombs, or other
imperfections.
2. Reinforcement Details:
- Slab reinforcement: #3 rebars spaced at 16" O.C. (On
Center) E.W. (Each Way).
- Beams reinforcement: 2 #5 rebars at the top and 2 #5
rebars at the bottom of each beam.
- All rebar to be ASTM A615 Grade 60 or approved
equivalent.
- Reinforcement must have a minimum of 2" concrete cover,
unless otherwise specified.
3. Slab on Grade:
- Slab thickness to be as specified on the plans.
- Provide control joints as per the structural design or
as indicated on the drawings.
- Ensure subgrade is properly compacted to avoid
settlement.
4. Beams:
- Beams dimensions as indicated on the plans.
- Provide adequate support and alignment for rebar
during the pour.
5. Formwork and Placement:
- All formwork to be installed true to line and level,
securely anchored to avoid displacement during concrete
placement.
- Concrete to be placed continuously and vibrated to
avoid voids.
6. Curing:
- Cure concrete as per standard practice or as specified
in the project specifications to ensure strength development
and minimize shrinkage cracking.
7. Inspection:
- All reinforcement and formwork must be inspected and
approved by the structural engineer or designated inspector
before concrete placement.
8. Quality Control:
- Concrete samples to be taken during placement to
confirm compliance with specified strength.
- Any deviations from the plan must be approved by the
engineer.
9. Coordination:
- Coordinate with other trades to ensure no conflicts
with plumbing, electrical, or other embedded items within the
Reinforcement Notes:
1. Rebar Strength:
- All reinforcing steel shall be ASTM A615
Grade 60 with a yield strength of 60,000 psi.
2. Rebar Splices:
- Splicing of rebar shall only be permitted at
locations shown on the structural drawings.
- Lap splices for #3 rebars: 12 inches minimum or
as specified on the plans.
- Lap splices for #5 rebars: 24 inches minimum or
as specified on the plans.
- All splices to be staggered and not located at
points of maximum stress unless specifically
detailed on the plans.
3. Rebar Bends:
- All rebar bends must conform to ACI 318
standards.
- Minimum bend diameter for #3 rebar: 6x bar
diameter.
- Minimum bend diameter for #5 rebar: 8x bar
diameter.
- Field bending of rebar is not permitted unless
approved by the structural engineer.
4. Concrete Coverage:
- Minimum concrete cover for rebar in slabs
exposed to weather or in contact with the ground: 3
inches.
- Minimum concrete cover for rebar in beams:
- 2 inches for top and bottom rebar.
- 1.5 inches for rebar at sides of beams unless
otherwise specified.
- Concrete cover to be verified and maintained
during placement to ensure durability and
protection of the rebar from corrosion.
5. Rebar Placement:
- Rebars shall be placed accurately according to
the plan dimensions and securely fastened to
prevent displacement during concrete placement.
- Use approved chairs, spacers, and ties to
maintain required cover and spacing.
6. Inspection and Approval:
- All rebar splices, bends, and cover shall be
inspected by the structural engineer or designated
inspector before concrete placement.
- Any deviation from the specified rebar layout,
splicing, or bending must be reviewed and approved
by the structural engineer.
18X24 TEMPLATE SCALE:DATE:PROJECT:SCOPE OF WORK:THIS SET OF PLANS HAS BEEN DEVELOPED IN ACCORDANCE WITH THE APPLICABLE CODES AND ZONING REGULATIONS OF THE JURISDICTION IN WHICH THE PROJECT IS SUBMITTED FOR REVIEW.THE DRAWINGS WERE PREPARED BASED ON INFORMATION PROVIDED BY THE OWNER AND WERE MADE AVAILABLE FOR THEIR REVIEW PRIOR TO SUBMISSION. THE OWNER AND/OR THEIR SELECTEDCONTRACTOR HAD SUFFICIENT TIME AND OPPORTUNITY TO REVIEW THE DOCUMENTS AND PROPOSE ANY NECESSARY REVISIONS. THE STRUCTURAL PLANS WERE REVIEWED AND STAMPED BY ALICENSED STRUCTURAL ENGINEER IN THE STATE OF TEXAS. THE PLAN PREPARER IS NOT RESPONSIBLE FOR CURRENT OR FUTURE STRUCTURAL DETAILS. ANY SIGNIFICANT STRUCTURAL CHANGESDURING CONSTRUCTION MUST BE COMMUNICATED AND APPROVED PRIOR TO EXECUTION. THE PLAN PREPARER ASSUMES NO RESPONSIBILITY FOR ERRORS, OMISSIONS, OR DEFICIENCIES THAT MAYOCCUR DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE APPROPRIATE MATERIALS, CONSTRUCTION METHODS, AND LABOR USEDTHROUGHOUT THE EXECUTION OF THE PROJECT. THE PLAN PREPARER IS NOT INVOLVED IN THE CONSTRUCTION PHASE. THE OWNER AND/OR CONTRACTOR MAY MODIFY THE MEP (MECHANICAL,ELECTRICAL, AND PLUMBING) DESIGN AS NEEDED TO ADDRESS ON-SITE CONDITIONS OR PROJECT REQUIREMENTS. THE CLIENT IS GRANTED THE RIGHT TO USE THESE PLANS FOR A ONE-TIMEPROJECT ONLY. REPRODUCTION, REDISTRIBUTION, OR USE OF THESE PLANS FOR MULTIPLE PROJECTS WITHOUT THE PLAN PREPARER'S WRITTEN CONSENT IS STRICTLY PROHIBITED.PAGE:SHEET:DETACHED GARAGE2204 WOODSTOCK DRCOLLEYVILLE, TX 760341/4" = 1'-0"10/09/2026S-0035 OF 7FOUNDATION
SCALE: 1/4" = 1-0"
B.W.L. BB.W.L. AB.W.L. 1 B.W.L. 2
EXT 100% DECKING OSB
EXT 100% DECKING OSBA
A
EXT 100% DECKING OSBA EXT 100% DECKING OSBA
TENSION TIE BOLTED
HOLDOWNS (TYP)
21'-9"19'-7"WALL BRACING NOTES
1.All wall bracing to comply with SECTION R602.10.3(1) & R602.10.4
2024 IRC adopted by COLLEYVILLE, TX.
2.Install bracing panels as noted on attached sketch according to
details shown on this page.
3.Nail roof decking with 1-1/4" galvanized roofing nails or 16 guage 7/16"
min. crown staples spaced 3" o.c. on all panel edges and 6" o.c. in the
field.
CONTINUOUS DECKING OSB
MATERIAL MINIMUM
THICKNESS
WOOD
STRUCTURAL
PANEL
CONNECTION
CRITERIA
COVERED ALL AREA EXTERIOR WALLS
W/ DECKING OSB
3/8"AT 6" SPACING (PANEL EDGES) AND
AT 12" SPACING (INTERMEDIATE SUPPORTS)
SHEATHING METHOD CS-WSP
DESIGN LOADS:
EXPOSURE CATEGORY B
WIND SPEED NOT EXCEED 115 MPH
ATTACH TO
BOTTOM PLATE W/
8D NAILS, 6" O.C.
ATTACH TO
TOP PLATE W/
8D NAILS, 6" O.C.
A BRACING PANEL DETAIL
48" WIDE 716"
O.S.B. PANEL.
8D NAILS, 6"
O.C. ON EDGES.
8D NAILS, 12"
O.C. IN FIELD.
not to scale
ALTERNATE CORNER BRACING
Alternate location
for the second
TENSION TIE BOLTED HOLDOWN
TENSION TIE BOLTED HOLDOWN
These anchors can
be installed on
either side of
panel.
2x4 Studs, Typ.
OSB Bracing Panel.
Nail according to
"A" Bracing Panel detail.
OSB Bracing Panel.
Nail according to
"A" Bracing Panel detail.
B
18X24 TEMPLATE SCALE:DATE:PROJECT:SCOPE OF WORK:THIS SET OF PLANS HAS BEEN DEVELOPED IN ACCORDANCE WITH THE APPLICABLE CODES AND ZONING REGULATIONS OF THE JURISDICTION IN WHICH THE PROJECT IS SUBMITTED FOR REVIEW.THE DRAWINGS WERE PREPARED BASED ON INFORMATION PROVIDED BY THE OWNER AND WERE MADE AVAILABLE FOR THEIR REVIEW PRIOR TO SUBMISSION. THE OWNER AND/OR THEIR SELECTEDCONTRACTOR HAD SUFFICIENT TIME AND OPPORTUNITY TO REVIEW THE DOCUMENTS AND PROPOSE ANY NECESSARY REVISIONS. THE STRUCTURAL PLANS WERE REVIEWED AND STAMPED BY ALICENSED STRUCTURAL ENGINEER IN THE STATE OF TEXAS. THE PLAN PREPARER IS NOT RESPONSIBLE FOR CURRENT OR FUTURE STRUCTURAL DETAILS. ANY SIGNIFICANT STRUCTURAL CHANGESDURING CONSTRUCTION MUST BE COMMUNICATED AND APPROVED PRIOR TO EXECUTION. THE PLAN PREPARER ASSUMES NO RESPONSIBILITY FOR ERRORS, OMISSIONS, OR DEFICIENCIES THAT MAYOCCUR DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE APPROPRIATE MATERIALS, CONSTRUCTION METHODS, AND LABOR USEDTHROUGHOUT THE EXECUTION OF THE PROJECT. THE PLAN PREPARER IS NOT INVOLVED IN THE CONSTRUCTION PHASE. THE OWNER AND/OR CONTRACTOR MAY MODIFY THE MEP (MECHANICAL,ELECTRICAL, AND PLUMBING) DESIGN AS NEEDED TO ADDRESS ON-SITE CONDITIONS OR PROJECT REQUIREMENTS. THE CLIENT IS GRANTED THE RIGHT TO USE THESE PLANS FOR A ONE-TIMEPROJECT ONLY. REPRODUCTION, REDISTRIBUTION, OR USE OF THESE PLANS FOR MULTIPLE PROJECTS WITHOUT THE PLAN PREPARER'S WRITTEN CONSENT IS STRICTLY PROHIBITED.PAGE:SHEET:DETACHED GARAGE2204 WOODSTOCK DRCOLLEYVILLE, TX 760341/4" = 1'-0"10/09/2026S-0045 OF 7WALL BRACING
SCALE: 1/4" = 1-0"
DOGDMRR
R R
RREPR
CONNECT TO
EXISTING HOUSE
WPWPELECTRIC FIXTURE HEIGHTS
(UNLESS NOTED OTHERWISE)42"STANDARD
OUTLET
TYP. WALL
SWITCH48"WPR
DESCRIPTIONSYMBOL
ELECTRICAL - DATA - AUDIO LEGEND
CEILING FAN
25 CFM EXHAUST FAN
SINGLE POLE SWITCH
ELECTRICAL BREAKER PANELEP
GARAGE DOOR MOTORGDM
RECESSED LED LIGHT
WALL SCONCE
GFCI110V GFCI RECEPTACLE
110V RECEPTACLE
110V WATER PROOF RECEPTACLE
3 3 WAY SWITCH
CMD CARBON MONOXIDE DETECTOR
18X24 TEMPLATE SCALE:DATE:PROJECT:SCOPE OF WORK:THIS SET OF PLANS HAS BEEN DEVELOPED IN ACCORDANCE WITH THE APPLICABLE CODES AND ZONING REGULATIONS OF THE JURISDICTION IN WHICH THE PROJECT IS SUBMITTED FOR REVIEW.THE DRAWINGS WERE PREPARED BASED ON INFORMATION PROVIDED BY THE OWNER AND WERE MADE AVAILABLE FOR THEIR REVIEW PRIOR TO SUBMISSION. THE OWNER AND/OR THEIR SELECTEDCONTRACTOR HAD SUFFICIENT TIME AND OPPORTUNITY TO REVIEW THE DOCUMENTS AND PROPOSE ANY NECESSARY REVISIONS. THE STRUCTURAL PLANS WERE REVIEWED AND STAMPED BY ALICENSED STRUCTURAL ENGINEER IN THE STATE OF TEXAS. THE PLAN PREPARER IS NOT RESPONSIBLE FOR CURRENT OR FUTURE STRUCTURAL DETAILS. ANY SIGNIFICANT STRUCTURAL CHANGESDURING CONSTRUCTION MUST BE COMMUNICATED AND APPROVED PRIOR TO EXECUTION. THE PLAN PREPARER ASSUMES NO RESPONSIBILITY FOR ERRORS, OMISSIONS, OR DEFICIENCIES THAT MAYOCCUR DURING THE CONSTRUCTION PROCESS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING THE APPROPRIATE MATERIALS, CONSTRUCTION METHODS, AND LABOR USEDTHROUGHOUT THE EXECUTION OF THE PROJECT. THE PLAN PREPARER IS NOT INVOLVED IN THE CONSTRUCTION PHASE. THE OWNER AND/OR CONTRACTOR MAY MODIFY THE MEP (MECHANICAL,ELECTRICAL, AND PLUMBING) DESIGN AS NEEDED TO ADDRESS ON-SITE CONDITIONS OR PROJECT REQUIREMENTS. THE CLIENT IS GRANTED THE RIGHT TO USE THESE PLANS FOR A ONE-TIMEPROJECT ONLY. REPRODUCTION, REDISTRIBUTION, OR USE OF THESE PLANS FOR MULTIPLE PROJECTS WITHOUT THE PLAN PREPARER'S WRITTEN CONSENT IS STRICTLY PROHIBITED.PAGE:SHEET:DETACHED GARAGE2204 WOODSTOCK DRCOLLEYVILLE, TX 760341/4" = 1'-0"10/09/2026E-0017 OF 7ELECTRICAL PLAN
SCALE: 1/4" = 1-0"
STATEMENT OF PLANNING OBJECTIVES
Variance Request – Detached Two-Car Garage
Property Address: 2204 Woodstock Drive, Colleyville, TX 76034
Applicant: Michael Hershenberg
Requested Variance: Reduction of the required 10-foot side setback to 5 feet.
PROJECT DESCRIPTION & JUSTIFICATION
I am requesting approval of a setback variance to construct a detached two-car garage on my
residential property at 2204 Woodstock Drive.
The proposed garage falls within the allowable accessory structure square footage and lot coverage
requirements under the property's current zoning. However, due to the existing layout of the
residence, driveway, and available building area, I am requesting a reduction of the required 10-foot
side setback to 5 feet to accommodate a properly sized and functional two-car garage.
The proposed structure has been professionally designed to complement the existing residence and
maintain the overall architectural character and appearance of the property. The requested variance
would allow for practical use of the available space while maintaining an appropriate separation from
neighboring properties.
Prior to the November Planning and Zoning presentation, I intend to obtain written acknowledgments
of support from the neighboring property owners located directly beside and behind my residence,
confirming their acceptance of the proposed design and placement.
My objective is to make a thoughtful improvement to my property that enhances its
functionality and long-term value while respecting the surrounding neighborhood and
adjacent homeowners.
I respectfully request the City's consideration and approval of this limited 5-foot setback variance as
illustrated in the attached architectural and site plans.
Thank you for your time and consideration.
Michael Hershenberg
Property Owner
2204 Woodstock Drive
Colleyville, TX 76034
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number 2e Agenda Date 10/26/2026 Number -
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a rezoning to PUD-C Planned Unit Development –
Commercial on Lot 1R, Block 1, The Gardens and Tract 3G, Abstract 963, Absalom J.
Lott Survey, zoned PUD-C Planned Unit Development – Commercial, located at 7009 and
7015 Colleyville Boulevard, Case ZC26-029 TABLED FROM THE OCTOBER 12, 2026,
PLANNING AND ZONING COMMISSION MEETING
Explanation
Fred Gans, the applicant, has submitted a request for a rezoning to PUD-C Planned Unit
Development - Commercial on Lot 1R, Block 1, The Gardens and Tract 3G, Abstract 963,
Absalom J. Lott Survey, being approximately 3.4 acres, and zoned PUD-C Planned Unit
Development – Commercial.
Attachments
1. Aerial Map
2. Future Land Use Map
3. Zoning Map
4. Site Plan
5. Concept Renderings
6. Ordinance O-26-2369
7. Notification Map
8. Notification Letter
7015
7015
7001
7005
7009
6808
6916
6918
2300
7171
2302
2304
2306
2308 2310
6900
6902
6904
6906
6908
6910
6912
6914
6901
2305
6903
2300
6903
6905
6907
69096910
6908
6906
6904
6905
6902
2204
2202
6907
6909
6911
6913
6915
2301
2505
2205
2201
7004
7000
2200
7171
7205
1901
6805 6805 68076804
6806
6808
6810 6812
6812
6814 6805
6803 6804
2201
7204
7200
2000
7205
7201
2100
72007204
7200
7203
7109
7101
7111
1908 7100
2050
7398
6901
6900
6930
6950
70017001
7009
7009
7001
2050
J
O
H
N
M
C
C
A
I
N
R
D
MEADEDRBROADOAKW AYDANIELLE DR COLEMANCTTHAMES TRK E N N E D Y DR GLENVIEWLNSTILL POINT
L
N
COLLEYVILLE BLVDK
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-009
7015 Colleyville Boulevard
Aerial Map
7015
7015
7001
7005
7009
6808
6916
6918
2300
7171
2302
2304
2306
2308 2310
6900
6902
6904
6906
6908
6910
6912
6914
6901
2305
6903
2300
6903
6905
6907
69096910
6908
6906
6904
6905
6902
2204
2202
6907
6909
6911
6913
6915
2301
2505
2205
2201
7004
7000
2200
7171
7205
1901
6805 6805 68076804
6806
6808
6810 6812
6812
6814 6805
6803 6804
2201
7204
7200
2000
7205
7201
2100
72007204
7200
7203
7109
7101
7111
1908
7100
2050
7398
6901
6900
6930
6950
7001 7001
7009
7009
7001
2050
J O H N M C C A I N RD
BROADOAKW AYMEADEDRDANIELLE DRCOLEMANCTTHAMES TRK E N N E D Y DR GLENVIEWLNSTILL POINT
L
N
COLLEYVILLE BLVDK
Residential
Colleyville Blvd Corridor
Open Space; Parks
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-009
7015 Colleyville Boulevard
Future Land Use Map
7015
7015
7001
7005
7009
6808
6916
6918
2300
7171
2302
2304
2306
2308 2310
6900
6902
6904
6906
6908
6910
6912
6914
6901
2305
6903
2300
6903
6905
6907
69096910
6908
6906
6904
6905
6902
2204
2202
6907
6909
6911
6913
6915
2301
2505
2205
2201
7004
7000
2200
7171
1901
6805 6805 68076804
6806
6808
6810 6812
6812
6814 6805
6803 6804
2201
7204
7200
2000
7205
7201
2100
72007204
7200
7203
7109
7101
7111
1908
7100
2050
7398
6901
6900
6930
6950
7001 7001
7009
7009
7001
2050
J O H N M C C A I N R D
BROADOAKW AYMEADEDRDANIELLE DRCOLEMANCTTHAMES TRK E N N E D Y DR GLENVIEWLNSTILL POINT
L
N
COLLEYVILLE BLVDAG
CC-2
PUD-R
ML
R-20
CC-2
CC-1
PUD-C
PUD-C
PUD-C
PUD-R
AG
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-009
7015 Colleyville Boulevard
Zoning Map
MIN 20' LANDSCAPE BUFFERMIN 10' LANDSCAPE BUFFERMIN 10' LANDSCAPE BUFFERCOLLEYVILLE BLVD8'x8'
RR
8'x8'
RR
BALCONY BALCONYBALCONY
BALCONYBALCONY BALCONYBALCONY
GARAGES
BLDG 3
24,000 SF
GARAGES
BLDG 4
24,000 SF
T
CIRS
1/2" IRF 5/8" IRF
CIRS
1/2" IRF
CIRFCIRF
5/8" IRF
X-CUT
5' LANDSCAPE BUFFER
9
CLUBHOUSE
13
14
16
5
A
D
A
-
B
F
R
A
D
A
-
B
F
R
A
D
A
-
B
F
R EXISTING SIDEWALK ALONG COLLEYVILLE BLVD
RETAIL
BLDG 1
13,500 SF
10
6
14
12
12
12 EXISTING TREES & NEWLY PROPOSED TREESADA-BFRADA-BFRADA-BFR7
EXT. DINING
PATIO
900 SF
12
MINIMUM 50' LANDSCAPE & DETENTION AREA.REFERENCE LANDSCAPE PLAN10
11
2
SIDEWALK AND OVERHEAD DOOR PAVING SLOPED(@ <1:12) TOWARDS EDGE OF BUILDING SLABLOADING
ZONE
8'x8'
RR
8'
x
8
'
R
R
EXISTING TREES & NEWLY PROPOSED TREESEXISTING TREES & NEWLY PROPOSED TREESRETAIL
2,500 SF
BALCONY
BALCONY
RETAIL
2,000 SF
RETAIL
2,000 SF
RETAIL
2,000 SF
RETAIL
2,000 SF
RETAIL
3,000 SF
ADA-BFRFLEX GARAGES
BLDG 2
24,000 SF
MIN 20' LANDSCAPE BUFFER
MIN 10' LANDSCAPE BUFFERMIN 10' LANDSCAPE BUFFERCOLLEYVILLE BLVD8'x8'
RR
8'x8'
RR
BALCONY BALCONYBALCONY
BALCONYBALCONY BALCONYBALCONY
GARAGES
BLDG 3
24,000 SF
GARAGES
BLDG 4
24,000 SF
T
CIRS
1/2" IRF 5/8" IRF
CIRS
1/2" IRF
CIRFCIRF
5/8" IRF
X-CUT
5' LANDSCAPE BUFFER
9
CLUBHOUSE
13
14
16
5
A
D
A
-
B
F
R
A
D
A
-
B
F
R
A
D
A
-
B
F
R EXISTING SIDEWALK ALON
G C
OLLEYVILLE BLVD
RETAIL
BLDG 1
13,500 SF
10
6
14
12
12
12 EXISTING TREES & NEWLY PROPOSED TREESADA-BFRADA-BFRADA-BFR7
EXT. DINING
PATIO
900 SF
12
MINIMUM 50' LANDSCAPE & DETENTION AREA.REFERENCE LANDSCAPE PLAN10
11
2
SIDEWALK AND OVERHEAD DOOR PAVING SLOPED(@ <1:12) TOWARDS EDGE OF BUILDING SLABLOADING
ZONE
8'x8'
RR
8'
x
8
'
R
R
EXISTING TREES & NEWLY PROPOSED TREESEXISTING TREES & NEWLY PROPOSED TREESRETAIL
2,500 SF
BALCONY
BALCONY
RETAIL
2,000 SF
RETAIL
2,000 SF
RETAIL
2,000 SF
RETAIL
2,000 SF
RETAIL
3,000 SF
ADA-BFRFLEX GARAGES
BLDG 2
24,000 SF
VICINITY MAP - N.T.S.
NORTH
Oak Alley
Shepherds GlenOrchard Hills CourtOak Alley DrivePebble Hill DriveCaldw
ell
C
r
e
e
k
D
ri
v
e
Milton
Drive
Armstr
o
n
g
C
o
u
r
t Balmoral DriveHol
ly LanePrimrose LaneJohn McCain Road
TEXR
ail
Tenni
s
o
n
P
ar
k
w
a
y
Dougl
a
s
A
v
e
n
u
eArmstrong CourtTEXR
ail
Cotton
b
elt
T
r
ail
Cotton
b
elt
T
r
ail
Majestic ManorDanielle Driv
e
T
h
am
e
s
T
r
a
i
l
Braemar TerraceBrooke DriveLongwood DriveBroa
d
o
a
k
W
a
y
John McCain Road
COLL
E
Y
VILL
E
BL
V
D
TEXR
ail
Kimzey ParkCommunity Trail
Charleston DriveMela
ni
e
Driv
e
Kennedy DriveCarriage DriveBeddo CourtAtlanta DriveCOLLEYVILLE BLVDArgos - Southlake
Plant
Cross Timbers
Middle School
Grapevine High
School
GHS Mustang
Softball Stadium
Bea r
C
r
e
e
k
T
r
a
i
l
Old Mill Run
Creek
vi
e
w
D
ri
v
e
Lon
gw
ood
D
r
i
ve Valley View DriveRidgebend DriveWilkes Drive
Ridg
e
v
i
e
w
D
r
i
v
eUpland
LanePool RoadPool RoadCOLLE
Y
V
I
L
L
E
B
L
V
D
TEXR
ail
Glenhope
Carriage Glen
Glenhope
Elementary
School
Twelv
e
O
aks
L
ane
Boxwood Drive
Horseshoe Drive
Pool RoadParr Park Butterfly
Habitat
Boxwood
D
r
i
v
e
SITE
LOCATION
ZONING:
PD: PLANNED DEVELOPMENT
PROPOSED USE: COMMERCIAL/RETAIL + GARAGES
AREA REQUIREMENTS:
MAX HEIGHT: 35' MAX
MIN. LOT SIZE: N/A
FRONT YARD SETBACK: 20'
SIDE YARD SETBACK: 10'
REAR YARD SETBACK: 10', 20' (RESIDENTIAL)
MAX BLDG. COVERAGE:< 50%
GARAGES OF AMERICA - COLLEYVILLE
CONCEPTUAL PLAN 19
7015 COLLEYVILLE BLVD | COLLEYVILLE, TX 76034
NOTE:
SITE PLAN IS FOR OWNER REVIEW ONLY. NOT FOR CONSTRUCTION, PERMITTING,
OR CITY APPROVAL PURPOSES. FINAL DESIGN TO BE COMPLETED BY REGISTERED
ARCHITECT / CIVIL ENGINEER.
-S I T E P L A N F O R R E V I E W O N L Y -
GENERAL NOTES:
CITY OF COLLEYVILLE FIRE DEPARTMENT SHALL HAVE 24 HOUR ACCESS TO THE
FACILITY THROUGH KNOX BOX OPERATED SLIDING GATES.
SIGNAGE: REQUIRES SEPARATE APPROVAL.
SANITATION CONTAINER: SHALL HAVE SCREENING WALLS OF BRICK, MASONRY,
STONE, CMU, OR OTHER ARCHITECTURAL FINISH. METAL GATE WILL BE PRIMED
AND PAINTED AND CONSTRUCTED IN ACCORDANCE WITH CITY DESIGN
SPECIFICATIONS.
MECHANICAL AND AIR CONDITIONING EQUIPMENT IN NON-RESIDENTIAL USES
SHALL BE SCREENED FROM VIEW OF PUBLIC RIGHT OF WAY AND FROM
ADJACENT RESIDENTIAL PROPERTIES.
SITE DATA:
LOT - AREA APPROX: 311,196 SF / 7.14 AC
SF TABLE
BUILDING AREA
(SF)TYPE
1 13,500 RETAIL SHELL
2 24,000 FLEX OFFICE / GARAGES
3 24,000 GARAGES
4 24,000 GARAGES
TOTAL W/ ALL
BUILDINGS 85,500 SF
REQUIRED ADA SPACES: 5 | PROVIDED ADA SPACES: 5
PARKING CALCULATIONS
SITE CONCEPTUAL PLAN | 10.14.26
NORTH GRAPHIC SCALE IN FT.
0'20'40'80'120'160'
1" = 40 FT
1 PROPOSED CONCEPTUAL PLAN
1" = 40'-0"
PROPOSED 8' MASONRY
SCREENING WALL
8' WROUGHT
IRON FENCING
2 CONCEPTUAL SITE PLAN - AERIAL OF EXISTING AREA
1" = 100'-0"
PROPOSED DRIVE WAY TO CONNECT TO PRE-EXISTING
DRIVEWAY, AND TO BE RECONFIGURED AND PROFILED AS
SHOWN HEREIN (REFER TO VIEW #2 ON THIS PLAN)
30' SLIDING
GATE
26' SWING
GATE
PROPOSED 8' MASONRY
SCREENING WALL
30" MASONRY VENEER
SCREENING WALL FOR
PARKING FACING
COLLEYVILLE BLVD
30' EXIT
ONLY
SLIDING
GATE
THIS PLAN, AND OTHER PROPOSED PLANS SHOWN IN THIS EXHIBIT SET, IS INTENDED
TO ILLUSTRATE THE GENERAL LAYOUT AND DESIGN INTENT OF THE DEVELOPMENT.
MINOR ADJUSTMENTS TO BUILDING LOCATIONS, PARKING AREAS, DRIVE AISLES,
LANDSCAPING, UTILITIES, AND OTHER SITE ELEMENTS MAY BE MADE DURING FINAL
DESIGN AND CONSTRUCTION, PROVIDED SUCH CHANGES DO NOT MATERIALLY ALTER
THE OVERALL CHARACTER OF THE DEVELOPMENT OR REDUCE COMPLIANCE WITH
APPLICABLE ZONING REGULATIONS.
DUMPSTER
ENCLOSURE
SITE DATA CALCULATIONS
CATEGORY DESCRIPTION AREA (SF)% OF SITE
BUILDING GROSS AREA PER BUILDING FOOTPINT 85,500 27%
PROPOSED
PAVING
SITE PAVING, DRIVE-APPROACH, & PARKING
(PROPOSED ONLY)151,524 49%
LANDSCAPING ALL LAWN, FOLIAGE, AND TREE ADDITIONS; OR THE RE-UTILIZATION OF
EXISTING PROTECTED TREES 74,172 24%
TOTALS 311,196 100%
SITE LEGEND
SYMBOL DESCRIPTION
PROPOSED LANDSCAPING AREA.
PROPOSED SIDEWALK AREA
PROPOSED PAVING AREA AND/OR STRIPING
ALL PROPOSED INSTALLATIONS ARE TO BE VERIFIED W/ ANY
APPLICABLE EASEMENT DEVELOPMENT AS REQUIRED. OWNER TO
VERIFY ALL PROPOSED INSTALLATIONS WITH THE PLANNING OFFICE
OF THE CITY OF COLLEYVILLE, THE RESPECTIVE ZONING,
DEVELOPMENT CODES, AND CITY ORDINANCES
DUMPSTER
ENCLOSURERETAIL/RESTAURANTTENANT SPACING SHOWN
FOR GRAPHICALPURPOSES ONLY, TBDPER FUTURE LEASING26' CRASH GATE
(EMERGENCY EXIT
ONLY)
8' WROUGHT
IRON FENCING
ORDINANCE 0-26-2369
AMENDING THE ZONING ORDINANCE AND THE OFFICIAL ZONING
MAP BY CHANGING THE ZONING ON 7.16 ACRES, BEING LOT 1R,
BLOCK 1, THE GARDENS, AND TRACT 3G, ABSTRACT 963, ABSALOM
J. LOTT SURVEY, LOCATED AT 7009 AND 7015 COLLEYVILLE
BOULEVARD, BY AUTHORIZING A REZONING FROM CC-1 VILLAGE
RETAIL, PUD-C PLANNED UNIT DEVELOPMENT COMMERCIAL, AND
AG AGRICULTURAL TO PUD-C PLANNED UNIT DEVELOPMENT
COMMERCIAL; PROVIDING A PENALTY OF FINE NOT TO EXCEED THE
SUM OF TWO THOUSAND DOLLARS ($2,000.00); AND PROVIDING
AN EFFECTIVE DATE
WHEREAS, the City of Colleyville has received an application for a rezoning
from CC-1 Village Retail, PUD-C Planned Unit Development
Commercial, and AG Agricultural to PUD-C Planned Unit
Development Commercial (Case ZC26-009); and
WHEREAS, the City of Colleyville deems it necessary, for the purpose of
promoting the health, safety, morals, or general welfare of the
City to enact a new zoning ordinance; and
WHEREAS, the Planning and Zoning Commission of the City of Colleyville,
has considered and made recommendations on the request,
having given the requisite notices, and having held due
hearings and affording a full and fair opportunity for all persons
interested in the matter to be heard; and
WHEREAS, after due deliberations and consideration of the
recommendation of the Planning and Zoning Commission, the
information received at a public hearing, and other relevant
information and materials, the City Council finds that this
amendment is in conformance with the Comprehensive Plan
for the City of Colleyville and promotes the general health,
safety, and welfare of this community.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE
CITY OF COLLEYVILLE, TEXAS:
Sec. 1. THAT the Comprehensive Zoning Ordinance of the City of
Colleyville, Texas, be, and the same is hereby amended by
authorizing a rezoning from CC-1 Village Retail, PUD-C Planned
Unit Development - Commercial, and AG Agricultural to PUD-
C Planned Unit Development - Commercial on 7.16 acres,
Ordinance 0-26-23(
Page 2 of
being Lot 1R, Block 1, The Gardens, and Tract 3G, Abstract
963, Absalom J. Lott Survey, located at 7009 & 7015 Colleyville
Boulevard, as depicted on the attached as Exhibit "A".
Sec. 2. THAT the above described tract of land shall be used only in
the manner and for the purposes provided by the Land
Development Code of the City of Colleyville as heretofore
amended, and as amended herein.
Sec. 3. THAT the above described tract of land shall be subject to the
following conditions:
1.GENERAL
a. Change the zoning to PUD-C Planned Unit Development -
Commercial.
b. The development shall be generally consistent with the
exhibits attached herein.
2. PERMITTED LAND USES
a. The following land uses will be permitted within this PUD-C,
provided the layout of the buildings and uses are consistent
with the site plan shown on Exhibit "C":
i. Garage Condominiums.
ii. Flex-Office/Warehouse Space.
iii. Automotive Repair/Paint and Body/Automotive
Upholstery/Automotive Customization.
i. Located minimum 100 feet away from residential
use/zoning district.
2. All repairs and servicing shall be conducted within
an enclosed building.
iv. All uses allowed in the CC-1 Village Retail and CC-2
Shopping Center zoning districts shall be permitted.
b. The following land uses are prohibited within this PUD-C:
i. Outdoor storage of vehicles or materials, including
overnight storage.
ii. Outdoor mechanical work (all work shall be conducted
indoors).
Ordinance 0-26-2369
Page 3 of 6
iii. Hotels/motels/short-term rentals.
iv. All residential uses.
3. CONCEPTUAL SITE PLANS AND PLATTING
a. The arrangement, location, and footprint of buildings within
this PUD-C shall be generally as shown on the attached
Exhibit "C".
b. The buildings and materials shall be generally consistent
with elevations depicted on the attached as Exhibit "D".
c. Prior to the issuance of any development permits within
this PUD-C and as a condition to the development of the
subject property, the developer shall obtain approval of a
final plat of the property in accordance with the procedures
and requirements of the Colleyville Land Development
Code.
4.LANDSCAPING /SCREENING
a. Landscaping and screening shall be generally consistent
with the landscape plan as depicted on the attached as
Exhibit "E".
b. A landscape buffer between 25 and 40 feet shall be
provided from the east property line. The buffer area shall
be a continuous, unimproved area, adjacent to residential
zoning/use reserved for landscaping and screening only.
c. The detention area shall be landscaped (trees around the
perimeter).
d. An eight -foot -tall masonry wall shall be constructed
adjacent to existing residential uses in accordance with the
Land Development Code. An eight -foot -tall wrought -iron
fence, with masonry columns to match the primary
materials used on the building, shall be constructed along
the south side of the proposed Buildings 3 and 4.
e. It shall be the property owners' responsibility to maintain
all landscaped areas, including areas between the
Ordinance 0-26-2369
Page 4 of 6
screening wall and adjacent fencing on any neighboring
property.
f. Screening, buffering, and landscaping shall meet the
minimum requirements of the Land Development Code,
except where amended herein.
5.SIGNAGE
a. The maximum area for wall signs shall only be calculated
using lineal width from non -garage tenant space.
b. No signage shall be permitted on building fagades facing
residential uses.
c. One wall sign shall be permitted for buildings 3 and 4.
d. All signage shall be generally consistent within the
development.
e. This development is permitted one monument sign.
f. All signs shall meet the minimum requirements of the Land
Development Code, except where amended herein.
6. PARKING AND ACCESS
a. Sufficient parking shall be provided to sustain each use, as
depicted on the attached Exhibit "C".
b. No off -site parking shall count towards the required
parking, unless authorized by the City Manager, or his/her
designee.
7. LIGHTING
a. All lighting shall be directed away from adjacent residential
properties. Illumination from outdoor lighting shall not
exceed one -quarter (1/4) foot-candles, as measured from
any portion of the property line.
b. Wall fixtures cannot be placed higher than eight feet from
grade.
Ordinance 0-26-2369
Page 5 of 6
c. The applicant shall be required to submit a photometric
plan to meet all minimum requirements of the Land
Development Code, or all other requirements as amended
herein.
d. All outdoor lighting shall use fully shielded fixtures to
prevent light pollution.
S. ARCHITECTURAL DESIGN
a. The architectural design and uniform sign plan shall be
generally consistent with the elevation drawings as
depicted on the attached as Exhibit "D".
Sec. 4. THAT any person, firm or corporation violating any of the
provisions or terms of this ordinance shall be subject to the
same penalty as provided for in the Comprehensive Zoning
Ordinance of the City of Colleyville, and upon conviction shall
be punishable by a fine not to exceed the sum of Two Thousand
Dollars ($2,000.00) for each offense.
Sec. 5. THAT it has been found that there has been a change in
conditions in the above described property, it is now necessary
that it be given the above zoning classification in order to
permit its proper development and in order to protect the
public interest, comfort and general welfare, and requires that
this ordinance shall take effect immediately from and after its
passage.
Sec. 6. THAT in addition to and accumulative of all other penalties, the
City shall have the right to seek injunctive relief for any and all
violations of this ordinance.
Sec. 7. THAT if any section, paragraph, subdivision, clause, phrase or
provision of this ordinance shall be judged invalid or
unconstitutional, the same shall not affect the validity of this
ordinance as a whole or any portion thereof other than that
portion so decided to be invalid or unconstitutional.
Sec. 8. THAT this ordinance shall take effect immediately from and
after its passage subject to the publication of the caption, as
the law or charter in such cases may provide.
AND IT IS SO ORDERED.
Ordinance 0-26-2369
Page 6 of 6
The first reading and public hearing being conducted on the 2nd day of June
2026.
The second reading and public hearing being conducted on the 16tn day of
June 2026.
APPROVED BY A VOTE OF 6 AYES, AND 0 NAYS, ON THIS THE 16TH DAY OF
JUNE 2026.
Mayor Bobby Lindamood Aye Mark Alphonso, Place 2 Aye
Mayor Pro Tern Brandi Elder Aye Ben Graves, Place 4 Aye
Deputy Mayor Pro Tern Scotty Richardson Aye Tim Raine, Place 6 Absent
Kimberly Holt Gunderson, Place 5 Aye
Christine Loven, TRMC
City Secretary
APPROVED AS TO FORM:
Whitt att
City Attorney
CITY OF YVILLE
LLLLLL `
L _ b I 1.. C
Bobby Lihd od
Mayor
Exhibit "A" - Aerial Map
Exhibit "B" - Statement of Planning Objectives
GARAGES OF AMERICA/TEXAS
What is a Garage Condo Facility?
Garage Condos are the latest concept in personal storage. It's a first-class garage
condominium project. These are unique facilities where the customer actually owns the
oversized garage / warehouse unit as opposed to renting it. Area residents can build equity
while enjoying the privacy and convenience of their own garage.
Every Garage Condo unit features a 14-foot high overhead door with commercial -grade
electric opener and two remotes, 22 to 24-foot-high ceilings, a 3-foot walk-in door,
mezzanine, air conditioning, an overhead heater, insulated walls and ceilings, individually -
metered electrical service with 125-amp panels, a dedicated RV power outlet, R-38 roof
insulation, fluorescent lighting, fire sprinklers, and pre -wiring for phone/cable/broadband
access.
Site and common area amenities shared by Garage Condo unit owners will include restroom
facilities, a spacious, private clubhouse for exclusive use by unit owners, 50 to 60-foot wide
drive aisles, trash and recycling service, access to potable water as well as an RV dump
station.
Design Strategy
The proposed Colleyville location will provide convenience and efficiency in site layout by
providing wide drive aisles and easy -to -access units. It is anticipated that screening of the
overhead doors will be important. Toward that end, we are attempting to screen the view to
the exterior of the site with mature trees and fencing. By providing landscape screening
with species as appropriate to best fit into this area of Colleyville, Texas.
A Garage Condo facility typically fits very well at the edges of commercial/industrial areas
and in transitional zones. We are an exceptional transitional development both in terms of
architecture and use. Our buildings can be designed with materials and scales reflective of
surrounding residential structures, while still conveying a commercial vernacular. The use is
low impact in frequency of traffic generation, noise, odor, vibration, glare, etc. Furthermore,
the typical Garage Condo unit owner is a nearby homeowner - so, even though it is a
commercial development, there is a noticeable residential `feel" to the facilities and in the
mind -set of the end users.
Individual unit sizes range from about 700 square feet up to 1,250 square feet, with most
units around 1,000 square feet. This size range has proven to be the most popular at our
other Garage Condo locations.
How Are Garage Condos Units Utilized?
1. Typically, 98% of units are purchased by car enthusiasts/collectors and the other 2%
are small businesses that comply with the condo docs as acceptable non -retail uses.
2. Historically, approximately 98% of units are owned by car collectors, hobbyists,
investors, and owners of similar 'toys'. Again, equipped with our market research, we
believe the proposed Garage Condos in Colleyville will see the higher end of this range as
automotive users.
3. About 2% to 5% of previous Garage Condo facilities have been purchased or
occupied by small businesses for storage of equipment and/or inventory. We anticipate
sales to such users to be within this range as well. These businesses primarily include
smaller trade contractors, light assembly, and 'Mom and Pop' type incubator businesses.
Retail businesses, signage, and business customers are not allowed in these units.
Employees are allowed only for short visits for loading and unloading. However, we are
planning to incorporate two flex buildings on the property for office/showroom/warehouse/
spaces as
part of this project designed specifically for such business users. Again, however, our
market projection indicates the buyers of the Garage Condos units will be primarily
automobile storage users.
The Benefits of Garage Condos for the community.
With more and more residential communities having stringent neighborhood covenants
restricting the size of garages, these 24/7 accessible, secured, covered, heated and
convenient spaces to store valuable belongings are in increasingly high demand.
There is a pride of ownership' component that the owners enjoy. The financial barrier of
entry' to acquire these units keeps the facilities somewhat exclusive, and the owners tend to
take great pride in ensuring that the facility is kept in good condition and adheres to the
published condominium declarations. Appreciation of their investment also plays an
important role.
The benefits for the community are also evident. A Garage Condos facility provides an
excellent property tax base with minimal infrastructure and service needs. The facility also
provides an attractive, useful alternative to the ongoing concern of storage enforcement.
Automobiles that were once stored in outdoor parking areas are now inside, protected, and
out of view.
City and County governments love Garage Condos. Garage Condos in Colleyville will:
Provide a $15,000,000 (+) property tax base - on a small (3.3 Acre) site
Provide an In -Community solution to outdoor vehicle storage.
Increase in sales tax revenue - when Garage Condos unit owners residing in
surrounding jurisdictions buy big ticket items and have them delivered to their unit, The City
and County receive sales tax that would otherwise flow to surrounding jurisdictions.
In addition, as unit buyers build out the interiors of their spaces, they will be shopping at
local Home Depot, Lowes and other supply houses for shelving, work benches, air
compressors, hose reels, and all manner of tools and equipment.
Generate very little traffic - much less than traditional mini -storage and considerably
less than commercial or industrial uses. Nonetheless, the project will pay the standard fees
required by all development projects.
Require minimal domestic water and sanitary sewer service - with only a couple of
restrooms, a kitchen sink, and a bunch of minimally utilized service sinks.
Demand almost no law enforcement and fire protection services
No impact on County School District resources.
Successful Track Record.
GOA helped create the very first Garages of America/Texas Condo project in DFW and Texas
in 2016. Since then, I have immersed myself and my team into the innovation, growth and
continuous improvement of this unique real estate product. To date I have built 12 Garage
Condo
projects and sold over 800 units. Currently there are 2 Garage Condo projects in various
stages of construction. Measured in terms of design, quality, amenities, sales velocity, land
planning, and a clear understanding of our customer's needs and priorities, the success of
these projects has been unparalleled by competitors. Thanks to a talented team of
professionals, and a commitment to satisfying the needs of all project stakeholders, we
have built on our successes and even raised unit prices throughout the development
process.
Flex Warehouse: The Garage Condominiums attracts several types of automotive related
businesses that are a perfect fit for Flex -Warehouse space with mezzanines. The spaces
vary in size per building for specific tenants.
The proposed use for building 1 is a 25,300 square foot flex building of which Innovative
Auto Sports will occupy 4,000 square feet, which services high end luxury and exotic
vehicles.
The proposed uses for building 2 include 4,000 square foot space for GoodGuys Club and
Grill, which is a sit-down restaurant serving beer and burgers, and will include an outdoor
patio. National headquarters for GoodGuys Rod and Custom Association, will occupy 10,000
square feet of office/warehouse. Also, PI Motor Lounge will occupy 21,300 square feet for a
car gallery and exotic car storage, where individuals store exotic cars, either on the floor
area or on lifts. Individual automotive storage/parking within a clear span building with
parking spaces for month -to -month storage.
Exhibit "C" - Site Plan
gg
1fillll
3f9 9- Y Z
fu
g4y
a rl, 'sal E
E $995I
P
f'
I 1— I r l 1 l T I I I -
j
u t l
6l A I F
r
Jill
I
e -
gEg
ggg
E
g
W
big
9jSS!$
a gg ®®gg99 '
p AikeSg ! •. I Gi i' P 8% c §$
Ifi 3 d di FF y @ 3!• 49!! O p ' Y z " '
i '4epWg s ,
4
44 WI Q2 pqI I EAM3 a p ,Id6§ q. $$§ Wg9 4tl F yR
GQjpZ9fl H 91 EIE GAY 6Y5 9 3 1 54 Q
Cli U R
GARAGES of --
A ` %TENLN t v .uMrA
J ' •
1
arc y" tjT
SH26 Facing Architecture and sign design
Car Club rfchEti
S1126 Facing Architecture and sign design
GARAG ES ot
j'+
a fe71
0
8
Exhibit "E" - Landscape Plan
w,eaiiw LV—OIU tlj0S3°Jtl21tlJ
i i I
e
1
R
e !1 ,
li }1 tj it !ia111!1 !a
v F . >p ss se 0
E1Y
L NN
E U
e
m
ti
d E
e
gib€gg
Aq
a._
E P
j ' `"• ':: , ` E E
1 Il I!+' !' !!e''!
i`
e!ell I; I I,'f!I jiI!!
O t a 1 •ii °u y!i lI 11 ll l•!f' 9! ! !i I!Ill!I'IIEaza!!II!119!!!IIJI1991191AI!!!E lil tn!ii!!191!i;
0
9
Q
aisa vomu a
VOR13WVd0S30VUVD
6if
Y d Y Y d duo ux>as la.asaad Y d YE '
p }
µ •` yyl E(dXdTtJ. G 5
lit ,
lit
Ae i
a J J J ?I?f?f ?M
1?
f
i
r le f}! S 11 JI ;!i!iiik
q
7015
7015
7001
7005
7009
6808
6916
6918
2300
7171
2302
2304
2306
2308 2310
6900
6902
6904
6906
6908
6910
6912
6914
6901
2305
6903
2300
6903
6905
6907
69096910
6908
6906
6904
6905
6902
2204
2202
6907
6909
6911
6913
6915
2301
2505
2205
2201
7004
7000
2200
7171
7205
1901
6805 6805 68076804
6806
6808
6810 6812
6812
6814 6805
6803 6804
2201
7204
7200
2000
7205
7201
2100
72007204
7200
7203
7109
7101
7111
1908
7100
2050
7398
6901
6900
6930
6950
7001 7001
7009
7009
7001
2050
J OHN MCCAIN RD
BROADOAKW AYMEADEDRDANIELLE
D
RCOLEMANCTTHAMES TRK E NN E D Y DR GLENVIEWLNSTILL POINT
L
N
COLLEYVILLE BLVDK
Subject Property
Notification Buffer
Parcels to be notified
Protest Buffer
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-029
7015 Colleyville Boulevard
Notification Map
NOTICE OF PUBLIC HEARING
«Owner_Name»
«Owner_Address»
«Owner_City» «Owner_Zip»
The City of Colleyville has scheduled a public hearing concerning the below referenced request on the
following date and location:
Planning & Zoning Commission Meeting: Monday, October 12, 2026, at 7:00 p.m.
City Council Meetings: Wednesday, November 4, and Tuesday, November 17, 2026, at 7:00 p.m.
3rd floor of City Hall, 100 Main Street, Colleyville, Texas
Request: Consideration of a rezoning to PUD-C Planned Unit Development -
Commercial, on Lot 1R, Block 1, The Gardens and Tract 3G, Abstract
963, Absalom J. Lott Survey, zoned PUD-C Planned Unit Development –
Commercial, located at 7009 & 7015 Colleyville Boulevard, Case ZC26-
029. The request is to amend the existing Planned Unit Development.
Zoning Case: ZC26-029 Applicant: Fred Gans
Location: 7009 & 7015 Colleyville Boulevard
Property Description: Lot 1R, Block 1, The Gardens and Tract 3G, Abstract 963, Absalom J. Lott Survey Present Zoning: PUD-C Planned Unit Development – Commercial
All interested citizens will be given the opportunity to speak and be heard. If you are unable to attend, but
wish to have your opinions made a part of the public record, please submit written comments prior to the
public hearing, to the address or email below:
Community Development Department
City of Colleyville
100 Main Street
Colleyville, TX 76034
CitizenLetters@colleyville.com
NOTICE OF PUBLIC HEARING
This notice was sent to all real property owners within 500 feet of the request (shown in blue on the map).
State law requires a City Council supermajority vote to approve the zoning change if written protests are
submitted by owners of 20% or more of the property within the 200-foot notification area (shown in black).
Scan the QR code below to view the project description on the Active Development Map:
For additional information, please contact the Community Development Department at 817-503-1050.
Please reference the zoning case number when requesting information.
Daniel Ponder
Daniel Ponder
Planning Manager
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number - Agenda Date 10/26/2026
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a rezoning from CC-2 Shopping Center and ML Light
Manufacturing to PUD-C Planned Unit Development – Commercial on Tracts 3A01, 3A,
and 4, Abstract 963, Absalom J. Lott Survey, located at 6930/6900 Colleyville Boulevard
and 1701 John McCain Road, Case ZC26-033
Explanation
Wes Hoblit, the applicant, has submitted a request for a rezoning from CC-2 Shopping
Center and ML Light Manufacturing to PUD-C Planned Unit Development – Commercial
on Tracts 3A01, 3A, and 4, Abstract 963, Absalom J. Lott Survey, being approximately
37.2 acres. The request is to rezone for a commercial development to include a golf
range, restaurant, retail, and office uses.
Attachments
1. Aerial Map
2. Future Land Use Map
3. Zoning Map
4. Concept Plan
5. Elevations
6. Phasing Plan
7. Tree Preservation Plan
JOHN MCCAIN RD
TENN ISON PKWY
CASPIAN
L N
MEADE DRCALDWELLCREEKDRKENNEDY DRBRAEMARTERRPEBBLE HILL DRHEATH
E
R
M
O
R
EBELLE MEADEDRMAJESTIC MNRMEL
A
N
I
E
DR
COL L I NS P A TH
THAMES TRMILTONDRSTILTONCTPRINCE MEADOW DR
MARANATHA CTD OU GL AS AVE BROOKEDRPRIMROSE LNROSEBROOKCOLLEYVILLE BLVDBALMORAL DRCARRIAGE LN
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-033
6930/6900 Colleyville Boulevard &
1701 John McCain Road
Aerial Map
JOHN MCCAIN RD
TENN ISON PKWY
CASPIAN
L N
MEADE DRCALDWELLCREEKDRKENNEDY DRBRAEMARTERRPEBBLE HILL DRHEATH
E
R
M
O
R
EBELLE MEADEDRMAJESTIC MNRMEL
A
N
I
E
DR
COL L I NS P A TH
THAMES TRMILTONDRSTILTONCTPRINCE MEADOW DR
MARANATHA CTD OU GL AS AVE BROOKEDRPRIMROSE LNROSEBROOKCOLLEYVILLE BLVDBALMORAL DRCARRIAGE LN
K
Residential
Colleyville Blvd Corridor
Open Space; Parks
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-033
6930/6900 Colleyville Boulevard &
1701 John McCain Road
Future Land Use Map
JOHN MCCAIN RD
MEADEDRTENN
ISONPKWYCALDWELLCREEKDR BRAEMARTERRKENNEDY DRMAJESTIC MNRMELANIEDRPEBBLE HILL DRHEATH
E
R
M
O
R
EBELLEMEADEDR THAMES TRCOLLI
N
S
P
A
T
H
MILTONDRSTILTONCTPRINCE MEADOW DR
DOU GLA S AVE MARANATHA CTBROOKEDRPRIMROSE LNCOLLEYVILLE BLVDBALMORAL DRROSEBROOKCARRIAGELNAG
PUD-R CC-2
PUD-R
PUD-R
R-20
ML
R-20
PUD-R
CC-2
ML
ML
PUD-C
PUD-R
AG
PUD-C
R-20
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-033
6930/6900 Colleyville Boulevard &
1701 John McCain Road
Zoning Map
GATEWAY GROVE
COLLEYVILLE, TEXAS1 | 2026.10.12
CONCEPT SKETCH
SCALE: 1" = 150’-0”
GATEWAY GROVE
COLLEYVILLE, TEXAS2 | 2026.10.12
RESTAURANTS
& RETAIL
STREETSCAPE
& ARRIVALCREEKSIDE
DINNING
PAR 3
PITCH & PUTT
DRIVING
RANGE
OFFICE COMPLEX
TRAINING &
WELLNESS
RETAIL
CONCEPT SKETCH
SCALE: 1" = 150’-0”
GATEWAY GROVE
COLLEYVILLE, TEXAS3 | 2026.10.12
CONCEPT IMAGES | ENTRY & APPROACH
GATEWAY GROVE
COLLEYVILLE, TEXAS4 | 2026.10.12
CONCEPT IMAGES | RESTAURANT & RETAIL
GATEWAY GROVE
COLLEYVILLE, TEXAS5 | 2026.10.12
CONCEPT IMAGES | CREEKSIDE DINING
GATEWAY GROVE
COLLEYVILLE, TEXAS6 | 2026.10.12
CONCEPT IMAGES | GOLF & PITCH PUTT
GATEWAY GROVE
COLLEYVILLE, TEXAS7 | 2026.10.12
CONCEPT IMAGES | PLANTING & MATERIALS
GATEWAY GROVE
COLLEYVILLE, TEXAS8 | 2026.10.12
CONCEPT IMAGES | PLANTING & MATERIALS
GATEWAY GROVE6930 COLLEYVILLE BLVD, COLLEYVILLE, TX 7603410.12.2026PUD SUBMITTALRETAIL / TRAINING CENTER
BUILDING ELEVATIONS
A201
1 FRONT ELEVATION
SCALE: N.T.S.
2 SIDE ELEVATION
SCALE: N.T.S.
3 PERSPECTIVE RENDERING
SCALE: N.T.S.
GATEWAY GROVE6930 COLLEYVILLE BLVD, COLLEYVILLE, TX 7603410.12.2026PUD SUBMITTALOFFICE BUILDING
ELEVATION
A202
1 REAR ELEVATION (DRIVING RANGE SIDE)
SCALE: N.T.S.
2 PERSPECTIVE RENDERING
SCALE: N.T.S.
GATEWAY GROVE
COLLEYVILLE, TEXAS2 | 2026.10.12
RESTAURANTS
& RETAIL
STREETSCAPE
& ARRIVAL COLLEYVILLE BLVD.COTTO
N
B
E
L
T
T
R
AI
L
CREEKSIDE
DINNING
PAR 3
PITCH & PUTT
DRIVING
RANGE
OFFICE COMPLEX
TRAINING &
WELLNESS
J
O
H
N
M
C
C
A
I
N
R
D
RETAIL
CONCEPT SKETCH
SCALE: 1" = 150’-0”
PHASING PLAN
DEVELOPMENT PHASING
PHASE 1 DRIVING RANGE & PAR 3 COURSE
PHASE 2 RETAIL / TRAINING BUILDING
PHASE 3 OFFICE BUILDING
PHASE 4 RESTAURANTS
1
2
3
4
BScale: 3/8" = 1' - 0"Tree Protection FencingEXISTING TREES REFER TOSURVEY FOR EXACT LOCATION.DRIPLINE-CANOPY EDGE OFTREE; VERIFY ON SITE.TRUNK PROTECTION(VERTICAL WOOD PLANKING &STRAPPING) TO FULLYSURROUND TRUNK6' STEEL T-POST; 6' O.C.4' CHAIN LINK FENCINGEXISTING GRADESDO NOT DISTURB AREA BENEATH TREE CANOPY. IFBARE SOIL EXISTS APPLY 2" DEPTH/LAYER OFSHREDDED HARDWOOD MULCH.ATREE PRESERVATION PLAN1" = 80'-0"0080'160'NORTHLEGENDTREE TO BE PRESERVEDTREE TO BE REMOVEDDBHSPECIESIDTREE PROTECTION NOTES:1.PRIOR TO COMMENCEMENT OF HARDSCAPE CONSTRUCTION, CONTRACTOR MUST HAVE ANLICENSED ARBORIST REVIEW ALL CONDITIONS WHERE EXISTING TREES ARE SUBJECT TODAMAGE DURING CONSTRUCTION.2.PROTECT EXISTING TREES AND PLANTS AT SITE THAT ARE DESIGNATED TO REMAIN WHEREINDICATED ON DRAWINGS AND AT OTHER LOCATIONS WHERE TREES ARE SUBJECT TO DAMAGEDURING CONSTRUCTION.3.PROVIDE CHAIN-LINK FENCE BARRIERS TO HEIGHT OF 4 FEET AROUND INDIVIDUAL AND/ORGROUPS OF TREES AND PLANTS AS SHOWN ON PLANS. REFER TO DETAILS & SPECIFICATIONS4.POST "KEEP OUT" SIGNS ON TREE PROTECTION ZONE (TPZ) FENCING.5.SUPERVISE EARTHWORK OPERATIONS TO PREVENT DAMAGE TO CRITICAL ROOT ZONES.6.ASSIGN A MONITOR TO MAINTAIN TPZ FENCING AND TO KEEP IN GOOD CONDITION FOR DURATIONOF CONSTRUCTION.7.HIRE A PROFESSIONAL ARBORIST TO COMPLETE REGULAR TREE MAINTENANCE TASK, INCLUDINGWATERING, FERTILIZATION, AND MULCHING TO PROTECT TREE ROOTS.8.PROTECT ROOT SYSTEM FROM DAMAGE CAUSED BY RUNOFF OR SPILLAGE OF NOXIOUSMATERIAL WHILE MIXING, PLACING, OR STORING CONSTRUCTION MATERIALS.9.MINIMIZE ALL TRENCHING FOR NEW UNDERGROUND UTILITIES IN AREAS WITH EXISTING TREES.10.PROTECT ROOT SYSTEM FROM PONDING, ERODING, OR EXCESSIVE WETTING CAUSED BYWATERING OPERATIONS.11.DO NOT STORE CONSTRUCTION MATERIALS, DEBRIS, OR EXCAVATED MATERIAL INSIDE TPZ.12.DO NOT PERMIT VEHICLES OR FOOT TRAFFIC WITHIN TREE PROTECTION ZONES; PREVENT SOILCOMPACTION OVER ROOT SYSTEM.13.MAINTAIN TPZ FREE OF WEEDS AND TRASH.14.MULCH AREAS INSIDE TPZ WITH 4" THICK LAYER OF ORGANIC MULCH. DO NOT PLACE MULCHWITHIN 6" OF TRUNK OF TREE.15.DO NOT EXCAVATE WITHIN TPZ, UNLESS OTHERWISE INDICATED OR APPROVED. TREE SHALL BEROOT PRUNED 1' OUTSIDE LIMIT OF REQUIRED EXCAVATION.16.WHERE EXCAVATION FOR NEW CONSTRUCTION IS REQUIRED WITHIN THE TPZ AND IS APPROVED,HAND PRUNE OR UTILIZE APPROVED ROOT PRUNING TECHNIQUES PRIOR TO USE OF EXCAVATIONEQUIPMENT.17.DO NOT ALLOW EXPOSED ROOTS TO DRY OUT BEFORE PLACING PERMANENT BACKFILL. PROVIDETEMPORARY EARTH COVER OR PACK ORGANIC MATERIAL AND WRAP WITH BURLAP. WATER ANDMAINTAIN IN MOIST CONDITION. TEMPORARY SUPPORT AND PROTECT ROOTS FROM DAMAGEUNTIL THEY ARE PERMANENTLY COVERED WITH SOIL.18.ROOT PRUNING SHALL BE DONE BY HAND WITH SHARP TOOLS OR IF DONE MECHANICALLY SHALLBE DONE WITH ROOT PRUNING MACHINERY, VIBRATORY PLOW, OR WITH A NARROW TRENCHERWITH SHARP BLADES. ONCE A TRENCH IS OPENED UP, ALL EXPOSED ROOTS WILL BE HANDPRUNED TO PROVIDE A CLEAN-CUT ENDS.19.DO NOT BREAK OR PULL ROOTS WITH A BACKHOE OR SIMILAR EQUIPMENT.Gateway GroveSHEET TITLE:SHEET NO:DATE
ISSUE LOG
DESCRIPTION
Colleyville, TexasPROJECT NO:26017TreePreservationPlanL100
AKEY PLAN1" = 80'-0"L502L501L503/AL503/BGateway GroveSHEET TITLE:SHEET NO:DATE
ISSUE LOG
DESCRIPTION
Colleyville, TexasPROJECT NO:26017KeyPlanL5000080'160'NORTH
Gateway GroveSHEET TITLE:SHEET NO:DATE
ISSUE LOG
DESCRIPTION
Colleyville, TexasPROJECT NO:26017MATCHLINE B/L503MATCHLINE L502MEDIUM/SMALL TREEPROPERTY LINEPROPERTY LINE
PROPERTY L
INELARGE TREEEX. TREE TO REMAINPARKING AREA;REF. CIVILFENCINGALANDSCAPE PLAN1" = 40'-0"0040'80'NORTHLandscapePlanL501
Gateway GroveSHEET TITLE:SHEET NO:DATE
ISSUE LOG
DESCRIPTION
Colleyville, TexasPROJECT NO:26017MATCHLINE A/L503MATCHLINE L502
MEDIUM/SMALL TREEPROPERTY LINEPR
O
P
E
R
T
Y
L
I
N
ELARGE TREEEX. TREE TO REMAINDRIVE & PARKING;REF. CIVILSITE FEATURE WALLSIDEWALKEX. SIDEWALKFENCINGBUILDING REF. ARCH.SCREENIG SHRUBPROPERTY LINEALANDSCAPE PLAN1" = 40'-0"0040'80'NORTHLandscapePlanL502
Gateway GroveSHEET TITLE:SHEET NO:DATE
ISSUE LOG
DESCRIPTION
Colleyville, TexasPROJECT NO:26017MATCHLINE L502MATCHLINE B/L503 BLANDSCAPE PLAN1" = 40'-0"MATCHLINE L501MATCHLINE A/L503
SCREENING SHRUBSPROPERTY L
INE
PROP
E
R
T
Y
L
I
N
E
LARGE TREEEX. TREE TO REMAINDRIVE & PARKING;REF. CIVILSITE FEATURE WALLSIDEWALKEX. SIDEWALKFENCINGBUILDING REF. ARCH.PROPERTY LINE
MEDIUM/SMALL TREEPROPERTY LINEALANDSCAPE PLAN1" = 40'-0"0040'80'NORTHLandscapePlanL503
BScale: 1/2" = 1' - 0"Shrubs & GroundcoverGROUNDCOVER- SEE PLANTINGSCHEDULE FOR SIZE AND SPACING.VARIESSEE PLANSDScale: 1/2" = 1'-0"Shrubs & Groundcovers @ Edge ConditionX/2 HARDWOOD MULCH, UNLESS OTHERWISESHOWN ON PLANSXX REF. PLANS FOR PLANT TYPEX/2X X
TRIANGULAR SPACINGSQUARE SPACINGAScale: 1/2" = 1' - 0"Container - 4" Caliper or SmallerPIT = 2X WIDTH OF ROOTBALLNOTE:PERFORM PERCOLATION TEST FOREACH TREE PIT. PROVIDE GRAVELSUMP, FILTER FABRIC, & STANDPIPE IF DRAINAGE DOES NOTOCCUR WITH IN 24 HRS.CScale: 1/2" = 1' - 0"Container - OrnamentalPIT = 2X WIDTH OF ROOTBALLTOP OF ROOT BALL TO BE 3"ABOVE ADJACENT SOIL.REMOVE EXCESS SOIL ATOPROOTBALL AND EXPOSE TREEROOT FLARETREE STAKING. ARBORSTAKEUNDERGROUND TREE STAKESPER MANUFACTURERSINSTRUCTIONS2" MULCH TO OUTSIDE EDGE OFWATERING RING. MULCH TYPE PERSPECS.TOP 1/3 OF BACKFILL TO BE 20%COMPOST MIX AND 80& NATIVE SOILBOTTOM 2/3 OF BACKFILL TO BE100% NATIVE SOILSCARIFY SIDES & BOTTOM OF PITUNDISTURBED SUBGRADETOP OF ROOT BALL TO BE 3"ABOVE ADJACENT SOIL.REMOVE EXCESS SOIL ATOPROOTBALL AND EXPOSE TREEROOT FLARETREE STAKING. ARBORSTAKEUNDERGROUND TREE STAKESPER MANUFACTURERSINSTRUCTIONS2" MULCH TO OUTSIDE EDGE OFWATERING RING. MULCH TYPE PERSPECS.TOP 1/3 OF BACKFILL TO BE 20%COMPOST MIX AND 80& NATIVE SOILBOTTOM 2/3 OF BACKFILL TO BE100% NATIVE SOILSCARIFY SIDES & BOTTOM OF PITUNDISTURBED SUBGRADENOTE:PERFORM PERCOLATION TEST FOREACH TREE PIT. PROVIDE GRAVELSUMP, FILTER FABRIC, & STANDPIPE IF DRAINAGE DOES NOTOCCUR WITH IN 24 HRS.HARDSCAPE AREA, REF. PLANSX = PLANT SPACING PER PLANT LEGENDX/2 = HALF OF PLANT SPACINGPREPARE SHRUB BED PERSPECIFICATIONS. PREPARED SOILTILLED INTO EXISTING. FINISHGRADE TO BE 1" BELOW ADJACENTEDGE. BED TO BE GRADED FORPOSITIVE DRAINAGE AND MOUNDEDWHERE APPLICABLESTEEL EDGING2" LAYER MULCH,REFER TO SPECS.UNDISTURBED SUBGRADEPLANT LEGEND:BOTANICAL NAMECOMMON NAMEPLANTABBR.MINIMUMHEIGHTMINIMUMSPREADMINIMUMSPACINGCOMMENTSMINIMUMSIZELRGLARGE TREE3"CAL.12'-13'4'-5'A.S.NURSERY GROWN, STANDARD, MATCHED, FULL, WELL BRANCHEDTREESPAPLANTING AREAIRRIGATED PLANTING AREA W/ TURF, NATIVE GRASSES, SHRUBS, AND GROUNDCOVERMEDMEDIUM/SMALL TREE2"CAL.8'-9'3'-4'A.S.NURSERY GROWN, MULTI-TRUNK, MATCHED, FULL, WELL BRANCHEDGateway GroveSHEET TITLE:SHEET NO:DATE
ISSUE LOG
DESCRIPTION
Colleyville, TexasPROJECT NO:26017COLLEYVILLE CODE OF ORDINANCES - CHAPTER 4STREET FRONTAGEREQUIRED = (1) 3" CAL. TREE @ 40'-0" O.C. SPACING FOR ALONG PUBLIC ROWPROVIDED = (1) 3" CAL. TREE @ 40'-0" O.C. MAX SPACING FOR ALONG PUBLIC ROWREQUIRED = (1) 5 GAL./18" HT SHRUB PER 5/LFPROVIDED = (1) 5 GAL./18" HT SHRUB PER 5/LFPARKING LOT TREEREQUIREMENTS –(1) TREE/140 SF ISLAND PER 18 PARKING SPACES (APPROX. 325 TOTAL SPACES)TOTAL TREES REQUIRED = 20TOTAL TREE PROVIDED = 32LANDSCAPE OPEN SPACE (PERVIOUS AREA)REQUIRED = 20% (310,883 SF)PROVIDED = 72% (1,118,816 SF)PLANTING CALCULATIONS:LandscapePlanL503
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number - Agenda Date 10/26/2026
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a Special Use Permit for a fence on Lots 26 and 27, Block
1, Colleyville Estates, zoned R-10 Single-Family Residential, located at 812 Colleyville
Terrace, Case ZC26-034
Explanation
Eddie Rollins, the applicant, has submitted a request for a Special Use Permit (SUP) for a
fence on Lots 26 and 27, Block 1, Colleyville Estates, being approximately 0.77 acres,
and zoned R-10 Single-Family Residential. The applicant is requesting a SUP to allow an
opaque wood fence approximately 15 feet from the east property line within the required
street side yard. Opaque wood fencing cannot be placed within the required street side
yard without the approval of a SUP, per Land Development Code Section 3.26(E)(2).
Attachments
1. Aerial Map
2. Future Land Use Map
3. Zoning Map
4. Site Plan
1000
5505
5505
5505
704
800
705
1000
908
909
1001
1000910
908
909 1001
5801
5709
5707
5705
5703
5701
5609
811
5706 5705
5703
5701 5700
5702
5704
5706 5707
5705
809
5703
5701
807805803
801
5700
5702
5704617
5508
5504
806804802800708
708 800 804 808 812
813
5513
5509
809805801709
705
705 709 713 801 PLEASANT RUN RDLAUREL OAKS LNGRAND OAK CTBENT TREE CTCHURCH ST
COLLEYVILLE TERR
THOMAS ST
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-034
812 Colleyville Terrace
Aerial Map
1000
5505
5505
5505
704
800
705
1000
908
909
1001
1000910
908
909 1001
5801
5709
5707
5705
5703
5701
5609
811
5706 5705
5703
5701 5700
5702
5704
5706 5707
5705
809
5703
5701
807805803
801
5700
5702
5704617
5508
5504
806804802800708
708 800 804 808 812
813
5513
5509
809805801709
705
705 709 713 801 PLEASANT RUN RDLAUREL OAKS LNGRAND OAK CTBENT TREE CTCHURCH ST
COLLEYVILLE TERR
THOMAS ST
K
Residential
Colleyville Blvd Corridor
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-034
812 Colleyville Terrace
Future Land Use Map
1000
5505 5505
5505
704
800
705
1000
908
909
1001
1000910
908
909 1001
5801
5709
5707
5705
5703
5701
5609
811
5706 5705
5703
5701 5700
5702
5704
5706 5707
5705
809
5703
5701
807805803
801
5700
5702
5704617
5508
5504
806804802800708
708 800 804 808 812
813
5513
5509
809805801709
705
705 709 713 801 PLEASANT RUN RDLAUREL OAKS LNGRAND OAK CTBENT TREE CTCHURCH ST
COLLEYVILLE TERR
THOMAS ST
R-20
AG
CC-1
R-10
R-10
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC26-034
812 Colleyville Terrace
Zoning Map