HomeMy WebLinkAboutOrdinances (O-02-1348)-07/02/2002 ORDINANCE 0-02-1348 AN ORDINANCE OF THE CITY OF COLLEYVILLE, TEXAS, AMENDING CHAPTER 46, ARTICLE 1 - IN GENERAL, ARTICLE 2 - FIRE CODE, OF THE CODE OF ORDINANCES OF THE CITY OF COLLEYVILLE, TEXAS TO ADOPT THE 2000 EDITION OF THE INTERNATIONAL FIRE CODE; PROVIDING FOR THE ADOPTION OF LOCAL AMENDMENTS RECOMMENDED BY THE REGIONAL CODES COMMITTEE OF THE NORTH CENTRAL TEXAS COUNCIL OF GOVERNMENTS; AMENDING CHAPTER 22, ARTICLE 1 - IN GENERAL; PROVIDING FOR THE VIOLATION OF THIS ORDINANCE; PROVIDING FOR AN EFFECTIVE DATE; PROVIDING A PENALTY AND AUTHORIZING PUBLICATION. WHEREAS, the City Council of the City of Colleyville has determined that it is in the best interest of the citizens of Colleyville, Texas to adopt the 2000 Edition of the International Fire Code; and the City Council of the City of Colleyville has determined that it is in the best interest of the citizens of Colleyville, Texas to additionally adopt the local amendments to 2000 Edition of the International Fire Code as recommended by the Regional Codes Committee of the North Central Texas Council of Governments. WHEREAS, NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY COLLEYVILLE, TEXAS: Sec. 1. THAT, the above findings are hereby found to be true and correct and are incorporated herein in their entirety. Sec. 2. THAT, Chapter 46, Fire Prevention and Protection, Article I In General, Section 46-2; Limitations on use of roofing materials in multi-family residences, is amended to read as follows: Roof assemblies shall be divided into the classes defined below. Class A, B, C roof assemblies and roof coverings required to be listed by this section shall be tested in accordance with ASTM E or Ul 790. In addition, fire- retardant-treated wood roof coverings shall be tested in accordance with ASTM D 2898. The minimum roof coverings installed on buildings shall comply with Table 1505.1 listed Section 1505.1 of the International Building Code. Ordinance 0-02-1348 Page 2 of 34 a. (footnote) Unless otherwise required in accordance with the Urban Wildland Interface Code or due to the location of the building within a fire district in accordance with Appendix D of the International Building Code. Section 1505.1; Fire Classification, International Building Code, amend footnote band c to read as follows: a. All individual replacement shingles or shakes shall be in compliance with the rating required by Table 1505.1, International Building Code. b. Non-classified roof coverings shall be permitted on buildings of U occupancies having not more than 120 square foot of projected roof area. When exceeding 120 square foot of Projected roof area, buildings of U occupancies may use non-rated non-combustible roof coverings. Sec. 3. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-31; Uniform Fire Code - Adopted, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46-31. International Fire Code 2000 - Adopted There is adopted by the City Council for the purpose of prescribing regulations governing conditions hazardous to life and property from fire or explosion that certain code and standards known as the International Fire Code 2000 (IFC) including Appendices B, C, E, F, and G. Sec. 4. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-32; Same - Enforcement, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46-32 Enforcement. The fire code shall be administered and enforced by the office of the Fire Marshal, which is hereby established. The Fire Chief shall appoint the Fire Marshal and shall designate members of the fire department as may be necessary to enforce the provisions of this code. Sec. 5. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-33; Same - Definitions remains unchanged. Ordinance 0-02-1348 Page 3 of 34 Sec. 6. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-34; Same - Conflicting Provision, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46.34; - Conflicting provisions: International Fire Code adopted; conflicting provisions: a. Adopted. The International Fire Code, 2000 edition, as recommended by the International Code Council, one copy of which is on file in the Office of the City Secretary, City of Colleyville, Texas, is hereby adopted and incorporated by reference and made a part of this article as the fire code of the City, subject to and including by reference such amendments, deletions, corrections, and additions as shall appear in this article. b. Conflicting provisions. In the event of a conflict between the provisions of the fire code adopted and incorporated in subsection (a) of this section and this Code of Ordinances, City of Colleyville, Texas, the provisions of this article shall prevail. Sec. 7. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-34.1; Same - Amendments is hereby repealed in its entirety and a new section shall be added to read as follows: The following sections of the 2000 edition of the International Fire Code, as adopted in Section 46-31 , are hereby amended as follows: Chapter 1. Administration 1. Section 101.1; is amended to read as follows: 101.1 Title. These regulations shall be known as the Fire Code of the City of Colleyville, hereinafter referred to as "this code". 2. Section 102.4; International Fire Code, amended to read as follows: 102.4; Application of other codes. The design and construction of new structures shall comply with this code, and other codes as applicable, and any Ordinance 0-02-1348 Page 4 of 34 alterations, additions, changes in use or changes in structures required which are within the scope of this and other codes shall be made in accordance therewith. 3. Section 102.6; Referenced codes and standards, International Fire Code, amended to read as follows: 102.6; Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 and such codes, when specifically adopted, and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between the provisions of this code and the referenced standards, the provisions of this code shall apply. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the ICC Electrical Code shall mean the Electrical Code as adopted. 4. Section 103; is amended to read as follows: Section 103.1; General. The Fire Code shall be enforced by the Fire Prevention Division of the Fire Department. The function of this division shall be the implementation, administration, and enforcement of the provisions of this code. Section 103.2; Appointment. The Code Official (Fire Marshal) shall be appointed by the Fire Chief. Section 103.3; Deputies. The Fire Marshal, with the concurrence of the appointing authority, shall have the authority to appoint a deputy Code Official, other related technical officers, inspectors and other employees.. 5. Section 105.1.1; is amended to read as follows: Section 105.1.1; Permits Required. Permits required by this code shall be obtained from the Code Official. Permit fees, if any, shall be paid prior to the issuance of the permit. Permit fees are stipulated in Section 22-1, Code of Ordinances, City of Colleyville, Texas. Issued permits ... {balance unchanged}. Ordinance 0-02-1348 Page 5 of 34 6. Section 105.6.16, 105.6.35, and 105.7.9; are deleted. 7. Section 109.3; is amended to read as follows: 109.3; Violation Penalties. Any person, firm or corporation who violates a provision of this code..., shall be guilty of a misdemeanor punishable by a fine of not more than Two Thousand Dollars ($2,000.00) or by imprisonment not exceeding twenty (20) days or both such fine and imprisonment. (Remainder unchanged). 8. Section 111.4; is amended to read as follows: Section 111.4; Failure to comply. Any person, firm or corporation ... shall be liable for a fine not to exceed Two Thousand Dollars ($2,000.00). Chapter 2. Definitions. 9. Section 202; International Fire Code, amended, to add: a. Emergency Access Easement. An access road or fire lane located on private property dedicated by the owner(s) of the property to provide fire apparatus access. b. High-Rise Building. Any structure used for human occupancy and/or storage more than 55 feet above the lowest level of fire department vehicle access. c. Self-Service Storage Facility. Real property designated and used for the purpose of renting or leasing individual spaces to customers for the purpose of storing and removing personal property on a self-service basis. d. Standby Personnel. Qualified fire service personnel, approved by the Fire Chief. When utilized, the number required shall be as directed by the Fire Chief. e. Code Official. The Fire Chief, Fire Marshal, or member of the fire department charged with the duties of administration and enforcement of this code, or a duly authorized representative. Ordinance 0-02-1348 Page 6 of 34 f. Reviewed. Reviewed by the office of the Code Official/Fire Marshal office for code compliance. g. Contractor's Board. The Board of Appeals of the City of Colleyville, Texas h. City. Shall mean the City of Colleyville, Texas. Chapter 3. General Precautions Against Fire 10. Section 307.2; Permit required, International Fire Code, delete. 11. Section 307.3; Location, International Fire Code, delete. 12. Section 307.3.1; Bonfires, International Fire Code, delete. 13. Section 307.3.3; Trench Burns, International Fire Code, add to read as follows: 307.3.3; Trench Burns, Shall not be allowed. 14. Section 307.4; Attendance, International Fire Code, amended to read: 307.4; Attendance. Attendance shall be constantly attended until the fire is extinguished. An approved method of extinguishing the fire must be on-site and available at all times during the course of the burn. A permit shall be obtained from the Code Official. 15. Section 307.5; Open-flame cooking devices, International Fire Code, amended to read as follows: 307.5; Open-flame cooking devices. Charcoal burners and other open-flame cooking devices shall not be operated or located on combustible balconies or within ten (10) feet of combustible constructions. Exceptions: 1. One-and-two-family dwellings. 2. Where buildings, balconies, and decks are protected by an approved automatic sprinkler system. Ordinance 0-02-1348 Page 7 of 34 16. Section 307.5.1; Liquefied-petroleum-gas-fueled cooking devices. International Fire Code, amended to read as follows: 307.5.1; Liquefied-petroleum-gas-fueled cooking devices. When permitted as listed in the exceptions of Section 307.5,LP-gas burners having alP-gas container with a water capacity greater than 2.5 pound lP-gas capacity shall not be located on combustible balconies or within 10 feet of combustible construction. Exception: One-and two-family dwellings, and other residential occupancies when those residential occupancies are In compliance with Section 307.5, exception # 2, may have containers with a water capacity not greater than 20 pounds LP-gas capacity. Chapter 5 Fire Service Features. 17. Section 503.1.1; Building and facilities, International Fire Code, add a sentence to first paragraph: 503.1.1; Buildings and facilities. Except for single-or two-family residences, the path of measurement shall be along a minimum of a ten feet (10') wide unobstructed pathway around the external wall of the structure. 18. Section 503.2.1; International Fire Code, amended to read as follows: 503.2.1; Dimensions. Fire apparatus access roads shall have an unobstructed width of not less than 24 feet and an unobstructed vertical clearance of not less than 14 feet. Exception: Amended Section 503.6 Security Gates; add: Security Gates, shall have an unobstructed width of not less than 20 feet and an unobstructed vertical clearance of not less than 14 feet. Approved signage shall be provided on each side of each section of Security Gates. Signs shall be provided by the Fire Marshal as part of the permit process. Signs shall be permanently affixed to the security gate as required by the Fire Marshal. Ordinance 0-02-1348 Page 8 of 34 19. Section 503.2.2; Authority. International Fire Code, amended to read as follows: 503.2.2; Authority. The Code Official shall have the authority to require an increase in the minimum access widths and vertical clearance where they are inadequate for fire or rescue operations. 20. Section 503.3; Marking, International Fire Code, amended to read as follows: 503.3; Fire Apparatus Access Roads. Marking- Approved striping or, when allowed by the Code Official, signs, or both, shall be provided for fire apparatus access roads to identify such roads or prohibit the obstruction thereof. Signs and striping shall be maintained in a clean and legible condition at all times and be replaced or repaired when necessary to provide adequate visibility. Striping - Fire apparatus access roads shall be marked by painted lines of red traffic paint six (6") inches in width to show the boundaries of the lane. The words "NO PARKING FIRE LANE" shall appear in four (4") inch white letters at 15 feet intervals on the red border markings along both sides of the fire lanes. Where a curb is available, the striping shall be on the vertical face of the curb. Signs - Sign shall read "NO PARKING FIRE LANE" and shall be twelve (12") inches wide and eighteen (18") inches high. Signs shall be painted on a white background with letters and borders in red, using not less than two (2") inch lettering. Signs shall be permanently affixed to a stationary post and the bottom of the sign shall be six (6') feet, six (6") inches above finished grade. Signs shall be spaced not more than fifty (50') feet apart. Sign may be installed on permanent buildings or walls or as approved by the Fire Chief. 21. Section 503.4; Obstruction of fire apparatus access roads, International Fire Code, amended to read as follows: 503.4; Obstruction of fire apparatus access roads. Fire apparatus access roads shall not be obstructed in Ordinance 0-02-1348 Page 9 of 34 any manner, including the parking of vehicles. The minimum widths and clearances established in Section 503.2.1 and any area marked as a fire lane as described in Section 503.3 shall be maintained at all times. 22. Section 508; International Fire Code, add Section 508.5.1, to read as follows: 508.5.1; Where required. When a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 300 feet from a fire hydrant on the fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and water mains shall be provided where required by the Fire Marshal. Exception: For Group R-3 and Group U occupancies, the distance requirement shall be 500 feet. Exception 2 is deleted. 23. Section 508.5.2; International Fire Code, add to read as follows: 508.5.2; Fire hydrants. All fire hydrants located on publiC or private property, shall be in accordance with the Code of Ordinance, City of Colleyville, Texas. Appendix A, Water and Sewer Policy and Procedure Manual, Section 7, sub-section c. 24. Section 508.5.2.1; International Fire Code, add to read as follows: 508.5.2.1; Fire hydrant location. The location of fire hydrants on private property or along a fire access roads shall be approved by the Fire Marshal. 25. Section 508.5.2.3; International Fire Code, add to read as follows: 508.5.2.3; Fire hydrants not installed on public streets. Fire hydrants that are not on public streets shall be looped to provide a water supply from two directions. Ordinance 0-02-1348 Page 10 of 34 26. Section 508.5.2.4; International Fire Code, add to read as follows: 508.5.2.4, Fire hydrant markings: All fire hydrants shall be identified by the painting of the body a Kem- lustral Vermillion Red or an equivalent coating. Equivalent must be approved by the Fire Marshal. The Fire Marshal may approve an alternative markings of existing hydrants. 27. Section 508.5.2.5; International Fire Code, add to read as follows: 508.5.2.5; Hydra-Storz connections, All fire hydrants whether on private property, public or a private street shall be equipped with a five inch (5") Hydra-Storz connector on the four and one half inch (4-1/2") steamer outlet. Chapter 7. Fire-Resistance-Rated Construction 28. Section 704.1; Enclosure, International Fire Code, amended to read as follows: 704.1; Enclosure. Interior vertical shafts, including but not limited to stairways, elevator hoist-ways, service and utility shafts, that connect two or more stories of a building shall be enclosed or protected in accordance with the codes in effect at the time of construction, but regardless of when constructed, not less than as specified in table 704.1. When openings are required to be (remainder of section unchanged). Chapter 8. Interior Finish, Decorative Materials and Furnishings 29. Section 804.1.1; Restricted occupancies. International Fire Code, add a second exception to read as follows: 804.1.1, Restricted occupancies. Exceptions: 1. Existing exception unchanged. 2. Trees shall not be prohibited inside private dwelling units of Group R-2 Occupancies. Ordinance 0-02-1348 Page 11 of 34 Chapter 9. Fire Protection Systems 30. Section 901.4; Installation, International Fire Code, amended to read as follows: 901.4; Installation. Fire protections systems shall be maintained in accordance with the original installation standards for that system. Required fire protection systems shall be extended, altered, or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Any alteration to the fire protection system must be approved and a permit issued by the Fire Marshal. Hydrostatic testing of the system may be required prior to the acceptance of any system alteration. 31. Section 901.7; System out of service, International Fire Code, amended to read as follows: 901.7; System out of service. Where a required fire protection system is out of service or in the event of an excessive number of accidental activation's, the fire department and the Code Official shall be notified immediately and , where required by the Code Official, the building shall either be evacuated or standby personnel shall be provided for all occupants left unprotected by the shut down until the fire protection system has been returned to service. Where utilized, standby personnel shall be provided with at least one approved means for notification of the fire department and their only duty shall be to perform constant patrols of the protected premises and keep fire watch. 32. Section 902.1; Definition of "Fire Area", International Fire Code, amended to read as follows: 902.1, Fire Areas. The aggregate floor area of a building regardless of the installation of fire walls, fire barriers, fire partitions, or demising walls. For the purpose of square footage requirements for a fire sprinkler system, the total building will be considered one structure. Buildings must be separated by a least twenty (20') feet to be considered separate buildings. 33. 902.1; Standpipes, Types of, International Fire Code, amend "wet dry" by adding a sentence to read as follows: Ordinance 0-02-1348 Page 12 of 34 The system must be supervised as specified in Section 905.2 34. Section 903.1.2; Residential systems. International Fire Code, amended to read as follows: 903.1.2; Residential systems. Unless specifically allowed by this code or the International Building Code, residential sprinkler systems installed in accordance with NFPA 13D or NFPA 13R shall not be recognized for the purposes of exceptions or reductions, commonly referred to a "trade-off' permitted by other requirements of this code. In addition, residential sprinkler systems installed in accordance with NFPA 13R must include attic sprinkler protection to be recognized for the purposes of such trade-off permitted by other requirements of this code. 35. Sections 903.2.1.1; Group A-1, International Fire Code, amended to read as follows: 903.2.1.1; Group A-1. An automatic sprinkler system shall be provided for Group A-1 where one of the following conditions exists: 1. The fire area exceeds 6,000 square feet. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than the level of exit discharge. 4. The fire area contains a multi-theater complex. 36. Section 903.2.1.2; Group A-2, International Fire Code, amended to read as follows: 903.2.1.2; Group A-2. An automatic sprinkler system shall be provided for Group A-2 occupancies where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than the level of exit discharge. 37. Section 903.2.1.3; Group A-3, International Fire Code, amended to read as follows: Ordinance 0-02-1348 Page 13 of 34 903.2.1.3; Group A-3. An automatic sprinkler system shall be provided for Group A-3 Occupancies where one of the following conditions exists: 1. The fire area exceeds 6,000 square feet. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than the level of exit discharge. Exception: Areas used exclusively as participant sports areas where the main floor area is located at the same level as the level of exit discharge of the main entrance and exit discharge. 38. Section 903.2.1.4; Group A-4, International Fire Code, amended to read as follows: 903.2.1.4; Group A-4. An automatic sprinkler system shall be provided for Group A-4 Occupancies where one of the following conditions exists: 1. The fire area exceeds 6,000 square feet. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than the level of exit discharge. Exception: Areas used exclusively as participant sports areas where the main floor area is located at the same level as the level of exit discharge of the main entrance and exit. 39. Section 903.2.7; Group R-1, International Fire Code, amended to read as follows: 903.2.7; Group R-1. An automatic sprinkler system shall be provided though-out buildings with a Group R-1 fire area. Exception: 1. Where guest rooms are not located more than one story in height and the building contains less than 20 guest rooms. Ordinance 0-02-1348 Page 14 of 34 2. A residential sprinkler system installed in accordance with Section 903.3.1.2 shall be allowed in buildings, or portions thereof, of Group R-1. 40. Section 903.2.8; Group R-2, International Fire Code, amended to read as follows: 903.2.8; Group R-2. An automatic sprinkler system shall be provided throughout all buildings with a Group R-2 fire area where any of the following conditions apply: 1. The R-2 is located more than two- story in height, including basements; or 2. The building contains more than three (3) dwelling units; or 3. The building contains fraternities and sororities with an occupant load of more than 10. 41. Section 903.2.8.1; Group R-2 Heights, International Fire Code, add to read as follows: 903.2.8.1; Group R-2 Heights. An R-2 Occupancy three or more stories in height shall be required to have a sprinkler system meeting the requirements of NFPA 13. 42. Section 903.2.10.2; Bulk storage of tires, International Fire Code, add to read as follows: 903.2.10.2; Bulk storage of tires. Buildings and structures where the area for the storage of tires exceeds 10,000 cubic feet, shall be equipped through- out with an automatic fire sprinkler system meeting the requirements of NFPA 13. 43. Section 903.2.10.3; Self-service storage facilities, International Fire Code, add to read as follows: 903.2.10.2; Self-service storage facilities. An automatic sprinkler system shall be installed throughout all self- service storage facilities. Ordinance 0-02-1348 Page 15 of 34 Exception: One-story self-service storage facilities that have no interior corridors, with a one-hour fire barrier separation wall installed between every storage compartment. 44. Section 903.2.12.3; Buildings over 35 feet in height, International Fire Code, amended to read as follows: 903.2.12.3; Buildings over 35 feet in height. An automatic sprinkler system shall be installed throughout buildings with a floor lever other than penthouses in compliance with Section 1509 of the International Building Codes that is located 35 feet or more above the lowest level of fire department vehicle access. Exception: Open parking garages in compliance with Section 406.3 of the International Building Code, provided fire department stand pipes and connections are installed in such a way that no portion of the garage is more than a 100 foot unobstructed hose lay from the connection. 45. Section 903.2.12.4; High-Piled Combustible Storage, International Fire Code, amended to read as follows: 903.2.12.4; High-Piled Combustible Storage. For any building with a clear height exceeding 12 feet shall be equipped throughout with an automatic fire sprinkler system meeting the requirements of NFPA 13. 46. Section 903.2.12.5; Spray Booths and Rooms, International Fire Code, amended to read as follows: 903.2.12.5; Spray Booths and Rooms. New and existing spray booths and spraying rooms shall be protected by an approved automatic fire extinguishing system. 47. Section 903.2.12.6; Buildings Over 6,000 square feet, International Fire Code, amended to read as follows: 903.2.12.6; Buildings Over 6,000 square feet. An automatic sprinkler system shall be installed throughout all buildings over 6,000 square feet. For the purpose of this provision, fire walls shall not define separate buildings. Ordinance 0-02-1348 Page 16 of 34 48. Section 903.3.1.1.1; Exempt locations, International Fire Code, amended to read as follows: 903.3.1.1.1; Exempt locations. When approved by the Code Official, automatic sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected with an approved automatic fire detection system in accordance with Section 907.2 that will respond to visible or invisible particles of combustion. Sprinklers shall not be omitted from any room merely because it is damp, or fire-resistance-rated construction or contains electrical equipment. 1. Any room where the application of water, or flame and water, constitutes a serious life or fire hazard. 2. Any room or space where sprinklers are considered undesirable because of the nature of the contents, when approved by the Code Official. 3. Generator and transformer rooms under the direct control of a public utility, separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire-resistance rating of not less than 2 hours. 49. Section 903.3.5; Water Supplies, International Fire Code, add a second paragraph to read as follows: 903.3.5; Water Supplies. Water supply as required for such systems shall be provided in conformance with the supply requirements of the respective standards; however, every fire protection system shall be designed with a 10 psi safety factor. 50. Section 903.4; Sprinkler system monitoring and alarms, International Fire Code, add a second paragraph after the exceptions to read as follows: 903.4; Sprinkler system monitoring and alarms. Sprinkler and standpipe system water-flow detectors shall be provided for each floor tap to the sprinkler system and shall cause an alarm upon detection of water flow for more than 45 seconds. All control valves in the sprinkler and standpipe systems except for the fire department hose connection valves shall be electrically supervised to initiate a supervisor signal at the central station upon tampering. Ordinance 0-02-1348 Page 17 of 34 51. Section 903.4; Sprinkler system monitoring and alarms, International Fire Code, delete exception 2. 52. Section 903.6.2; Spray booths and rooms, International Fire Code, amended to read as follows: 903.6.2; Spray booths and rooms. New and existing spray booths and spray rooms shall be protected by an approved automatic fire-extinguishing system in accordance with Section 1504. 53. Section 905.2; Installation standards, International Fire Code, amended read as follows: 905.2; Installation standards. Standpipe system shall be installed in accordance with this section and NFPA Manual dry standpipe systems shall be supervised with a minimum of 10 psig and a maximum of 40 psig air pressure with a highllow alarm. 54. Section 905.3.2; Building area, International Fire Code, Delete exception #1 and exception #2. 55. Section 905.4; Location of Class 1 standpipe hose connection, International Fire Code, item #5; amended to read as follows: 905.4; Location of Class I standpipe hose connection. Where the roof has a slope less than four units vertical in 12 units horizontal (33.3-percent slope), each standpipe shall be provided with a two-way hose connection located either on the roof or at the highest landing of stairways with stair access to the roof. An additional hose connection shall be provided at the top of the most hydraulically remote standpipe for testing purposes. 56. Section 905.9; Valve supervision, International Fire Code, add a second paragraph after the exceptions reads as follow: 905.9; Valve supervision. Sprinklers and standpipe system water-flow detectors shall be provided for each floor tap to the sprinkler system and shall cause an alarm upon detection of water flow for more than 45 seconds. All control valves in the sprinkler and Ordinance 0-02-1348 Page 18 of 34 standpipe systems except for fire department hose connection valves shall be electrically supervised to initiate a supervisory signal at the central station upon tampering. 57. Section 907.1.0; Fire Alarm Permit, International Fire Code, add to read as follows: 907.1.0; Fire Alarm Permit. A permit shall be required for any new, remodel or expansion of a fire alarm system. See Section 22-1 (b) Permit Fee Schedule listed in the Code of Ordinance, City of Colleyville, Texas. 58. Section 907.1.3; Design Standards, International Fire Code, add to read as follows: 907.1.3; Design Standards. All alarm systems new or replacement serving 50 or more alarm actuating devices shall be addressable fire detection systems. All alarm systems serving more than 75 smoke detectors or more than 200 total alarm activating devices shall be analog intelligent addressable fire detection systems. Exception: Existing systems need not comply unless the total building remodel or expansion initiated after the effective date of this code, as adopted, exceeds 30% of the building. When cumulative building remodel or expansion exceeds 50% of the building must comply within 18 months of permit application. 59. Section 907.2.3; Group E, International Fire Code, amended to read as follows: 907.2.3; Group E. A manual fire alarm system shall be installed in Group E educational occupancies. When automatic sprinkler systems or smoke detectors are installed, such systems or detectors shall be connected to the building fire alarm system. An approved smoke detection system shall be installed in Group E day care occupancies. Unless separated by a minimum of 100 feet open space, all buildings whether portable buildings or the main building, will be considered one building for alarm occupant load consideration and interconnection of alarm systems. Ordinance 0-02-1348 Page 19 of 34 60. Section 907.2.3; Group E, International Fire Code, amend exception # 1 and add exception # 1.1, to read as follows: Exception: 1. Group E educational and day care occupancies with an occupant load of less than 50 when provided with an approved automatic sprinkler system. 1.1 Residential In-Home day care with not more than twelve (12) children may use interconnected single station detectors in all habitable rooms. (For care of more than five children 2 % or less years of age, see Section 907.2.6.) 61. Section 907.2.12; High-rise buildings, International Fire Code, amended to read as follows: 907.2.12; High-rise buildings. Buildings having floors used for human occupancy located more than 55 feet above the lowest level of fire department vehicle access shall be provided with an automatic fire alarm system and an emergency voice/alarm communications system in accordance with Section 907.2.12.2. 62. Section 907.2.12; High-rise building, International Fire Code, exception # 3; amended to read as follows: 907.2.12; High-rise buildings exception #3. Buildings with an occupancy in Group A-5 in accordance with Section 303.1 of the International Building Code, when used for open air seating; however, this exception does not apply to accessory uses including but not limited to sky boxes, restaurants and similarly enclosed areas. 63. Section 907.2.12.2; International Fire Code, amend the beginning paragraph to read as follows: 907.2.12.2; Emergency voice/alarm communication system. The operation of any automatic fire detector, sprinkler water-flow device or manual fire alarm box shall automatically sound an alert tone followed by Ordinance 0-02-1348 Page 20 of 34 voice instructions giving approved information and directions on a general or selective basis to the following terminal areas on a minimum of the alarming floor, the floor above, and the floor below in accordance with the building's fire safety and evacuation plans required by Section 404. 64. Section 907.4; Manual fire alarm boxes, International Fire Code, add a second paragraph to read as follows: 907.4; Manual fire alarm boxes. Paragraph 2, Manual alarm actuating devices shall be an approved double action type. 65. Section 907.6.1; Installation, International Fire Code, add to read as follows: 907.6.1; Installation. All fire alarm systems shall be installed in a manner that the failure of any single alarm-actuating or alarm-indicating device will not interfere with the normal operation of any other such devices. All systems shall be Class "A" wired with a minimum of six feet separation between supply and return loops. IDe - Class "A" style - D - SlC Class "A" Style 6 - notification Class "B" Style Y. 66. Section 907.9.2; High-rise buildings, International Fire Code, amend to read as follows: 907.9.2; High-rise buildings. In buildings that have floors located more than 55 feet above the lowest level of fire department access that are occupied for human occupancy, a separate zone by floor shall be provide for all of the following types of alarm-initiating devices where provided: (Remainder of section unchanged). 67. Section 912.2; International Fire Code, add to read as follows: 912.2; Fire system connections. All fire department connections shall be located within fifty (50) foot hose lay of a fire hydrant. Fire department connections shall have a 42" by 42" concrete pad below each connection. The Fire Marshal shall approve the location of the fire department connection. Ordinance 0-02-1348 Page 21 of 34 68. Section 913.4; Valve supervision, International Fire Code, add a second paragraph to read as follows: 913.4; Valve supervision. The fire-pump system shall also be supervised for "loss of power", "phase reversal" and "pump running" conditions by supervisor signal on distinct circuits. Chapter 10. Means of Egress 69. Section 1003.2.12.2; Opening limitations, International Fire Code, exception # 3; amend to read as follows: 1003.2.12.2; Opening limitations. Exception: In occupancies in Group 1-3, F, H or in non-public portions of S, balusters, horizontal intermediate rails or other construction shall not permit a sphere with a diameter of 21 inches to pass through and opening. 70. Section 1004.3.2.1; Construction, International Fire Code, add exception #5 to read as follows: 1004.3.2.1; Construction. Exception: Group B office buildings, corridor walls and ceilings need not be of fire-resistive construction within office spaces of a single tenant when the space is equipped with an approved automatic smoke- detection system within the corridor. The actuation of any detector shall activate alarms audible in all areas served by the corridor. The smoke-detection system shall be connected to the building's fire alarm system where such a system is provided. 71. Section 1005.2.1; Minimum number of exits, International Fire Code, amended to read as follows: 1005.2.1; Minimum number of exits. Every floor area shall be provided with the minimum number of approved independent exits as required by Table 1005.2.1, based on the occupant load, except as modified in Section 1005.2.2. For the purposes of this chapter, occupied roofs shall be provided with exits as required for floors. The required number of exits from Ordinance 0-02-1348 Page 22 of 34 any story, basement or individual space shall be maintained until arrival at grade or the public way. 72. Section 1005.3.2.5; Smokeproof enclosures, International Fire Code, amended to read as follows: 1005.3.2.5; Smokeproof enclosures. In buildings required to comply with the high-rise provisions of the International Building Code or the provisions for underground buildings in the International Building Code, each of the exits of a building that serves stories where the floor surface is located more than 55 feet above the lowest level of fire department vehicles access or more than 30 feet below the level of exit discharge serving such floor levels shall be a smokeproof enclosure or pressurized stairway in accordance with International Building Code. Chapter 15. Flammable Finishes 73. Section 1504.6; Fire Protection, International Fire Code, amended to read as follows: 1504.6; Fire Protection. New and existing spray booths and spray rooms shall be protected by an approved automatic fire-extinguishing system complying with Chapter 9 which shall also protect exhaust plenums, exhaust ducts and both sides of dry filters when such filters are used. Chapter 23. High-Piles Combustible Storage 74. Section 2302; High-Piled Combustible Storage, International Fire Code, add a second paragraph to the definition of "High-Piled Combustible Storage" reads as follows: 2302; High-Piled Combustible Storage. Any building exceeding 6,000 square feet that has a clear height in excess of 12 feet, making it possible to be used for storage in excess of 12 feet, shall be considered to be high-piled storage and shall comply with the provisions of this section. When a specific product cannot be identified, a fire protection system shall be installed as for Class IV commodities, to the maximum pile height. Chapter 24. Tents and Other Membrane Structures Ordinance 0-02-1348 Page 23 of 34 75. Section 2416.1; Standby personnel/Crowd managers, International Fire Code, amended to read as follows: 2416.1; Standby personnel/Crowd managers. When, in the opinion of the Code Official, it is essential for public safety in a place of assembly or any other place where people congregate, because of the number of persons, or the nature of the performance, exhibition, display, contest or activity, the owner, agent or lessee shall employ standby personnel to remain on duty during the times such places are open to the public, or when such activity is being conducted. Before each performance or the start of such activity, standby personnel shall keep diligent watch for fires during the time such place is open to the public or such activity is being conducted and take prompt measures as directed by the Fire Chief. Such duties may include, but not limited to extinguishment of fires that occur and assist in the evacuation of the public from the structure. There shall be trained crowd managers or crowd manager supervisors at a ratio of one crowd manager/supervisor for every 250 occupants, as approved. Chapter 33. Explosives and Fireworks 76. Section 3301.1.3; Fireworks, International Fire Code, amended to read as follows: 3301.1.3; Fireworks. The possession, manufacture, storage, sale, handling of fireworks are prohibited. Exception: 1. Only when approved for fireworks displays, storage and handling of fireworks as provide in Section 3304 and Section 3308. 2. The use of fireworks for approved display as permitted in Section 3308. Chapter 34. Flammable and Combustible liquids 77. Section 3402; International Fire Code, add to read as follows: Ordinance 0-02-1348 Page 24 of 34 Fuel Limit Switch. A mechanism, located on a tank vehicle. which limits the quantity of product dispensed at one time. Mobile Fueling. The operation of dispensing liquid fuels from tank vehicles into the fuel tanks of motor vehicles. Mobil fueling may also be known by the terms Mobile Fleet Fueling; Wet Fueling; and Wet Hosing. Remote emergency Shut-Off Device. The combination of an operator carried signaling device and a mechanism on the tank vehicle. Activation of the remote emergency shut-off device sends a signal to the tanker mounted mechanism and causes fuel flow to cease. 78. Section 3403.6; Piping systems, International Fire Code, add a sentence to read as follows: 3403.6; Piping systems. An approved method of secondary containment shall be provided for underground tank and piping systems. 79. Section 3403.2.9.1.2; Foam fire protection system, installation page 281 of the International Fire Code is a misprint. Amend to read as follows: Section 3404.2.9.1.2; Foam fire protection system installations. 80. Section 3404.2.11.5; Leak Detection, International Fire Code, add a sentence to read as follows: 3404.2.11.5.2; Leak Detection. An approved method of secondary containment shall be provided for underground tank and piping systems. 81. Section 3404.2.11.5.3; Dump Sumps, International Fire Code, add to read as follows: 3404.2.11.5.3; Dry Sumps. Approved sampling tubes of a minimum 6 inches in diameter shall be installed in the backfill material of each underground flammable or combustible liquid storage tank. The tubes shall extend from a point 12 inches below the average grade of the excavation to ground level and shall be provided with suitable surface access caps. Each tank site shall Ordinance 0-02-1348 Page 25 of 34 provide a sampling sump at the corners of the excavation with a minimum of 4 sumps. Sampling tubes shall be placed in the product line excavation within 10 feet of the tank excavation and one every 50 feet routed along product lines towards the dispensers, a minimum of two are required. 82. Section 3406.5.4.1; Commercial, industrial, governmental or manufacturing, International Fire Code, add to read as follows: 3406.5.4.1; Site requirements. 1. Dispensing may occur at sites that have been permitted to conduct mobile fueling. 2. A detailed site plan shall be submitted with each application for a permit. The site plan must indicate: all buildings, structures, and appurtenances on site and their use or function; 3. All uses adjacent to the property lines of the site; 4. The locations of all storm drain openings, adjacent waterways or wetlands; 5. Information regarding slop, natural drainage, curbing, impounding and how a spill will be retained upon the site property; and 6. The Code Official is authorized to impose limits upon: the times and/or days during which mobile fueling operations are allowed to take place, and specific locations on a site where fueling is permitted. 7. Mobile fueling operations shall be conducted in areas not generally accessible to the public. 8. Mobil fueling shall not take place within 15 feet of buildings, property lines, or combustible storage. 83. Section 3406.5.4.2; International Fire Code, add to read as follows: 3406.5.4.2.1; Refueling Operator Requirements. 1. The owner of a mobile fueling operations shall provide to the jurisdiction a written response plan which demonstrates readiness to respond to a fuel spill, carry out appropriate mitigation measures, and to indicate its process to properly dispose of contaminated materials when circumstances require. Ordinance 0-02-1348 Page 26 of 34 2. The tank vehicle shall comply with the requirements of NFPA 385 and local, State and Federal requirements. The tank vehicle's specific functions shall include that of supplying fuel to motor vehicle fuel tanks. The vehicle and all its equipment shall be maintained in good repair. 3. Signs prohibiting smoking or open flames within 25 feet of the tank vehicle or the point of fueling shall be prominently posted on 3 sides of the vehicle including the back and both sides. 4. A fire extinguisher with a minimum rating of 40:BC shall be provided on the vehicle with signage clearly indicating its location. 5. The dispensing nozzles and hoses shall be of an approved and listed type. 6. The dispensing hose shall not be extended from the reel more than 100 feet in length. 7. Absorbent materials, non-water absorbent pads, a 10-foot long containment boom, an approved container with lid, and a non-metallic shovel shall be provided to mitigate a minimum 5-gallon fuel spill. 8. Tanker vehicles shall be equipped with a fuel limit switch such as a count-back switch, limiting the amount of a single fueling operation to a maximum of 500 gallons between resetting of the limit switch. Exception: Tankers utilizing remote emergency shut-off device capability where the operator constantly carries the shut-off device which, when activated, immediately causes flow of fuel from the tanker to cease. 9. Persons responsible for dispensing operations shall be trained in the appropriate mitigating actions in the event of a fire, leak, or spill. Training records shall be maintained by the dispensing company and shall be made available to the Code Official upon request. Ordinance 0-02-1348 Page 27 of 34 10. Operators of tank vehicles used for mobile fueling operations shall have in their procession at all times an emergency communications device to notify the proper authorities in the event of an emergency. 84. Section 3406.5.4.2; International Fire Code, amended to read as follows: 3406.5.4.2.3; Operational Requirements. 1. The tank dispensing equipment shall be constantly attended and operated only by designated personnel who are trained to handle and dispense motor fuels. 2. Prior to beginning dispensing operations, precautions shall be taken to assure ignition sources are not present. 3. The engines of vehicles being fueled shall be shut off during dispensing operations. 4. Night-time fueling operations shall only take place in adequately lighted areas. 5. The tank vehicle shall be positioned with respect to vehicles being fueled so as to preclude traffic from driving over the delivery hose and between the tank vehicle and the motor vehicle being fueled. 6. During fueling operations, tank vehicle brakes shall be set, chock blocks shall be in place and warning lights shall be in operation. 7. Motor vehicle fuel tanks shall not be topped off. 8. The dispensing hose shall be properly placed on an approved reel or in an approved compartment prior to moving the tank vehicle. 9. The Code Official and other appropriate authorities shall be notified when a reportable spill or unauthorized discharge occurs. Chapter 38, Liquefied petroleum Gases 85. Section 3803.2.1.8; International Fire Code, add to read as follows: 3803.2.1.8; Jewelry repair, Dental Labs and Similar Occupancies. Where natural gas service is not available, portable lP-Gas containers are allowed to be used to supply approved torch assemblies or similar Ordinance 0-02-1348 Page 28 of 34 appliances. Such containers shall not exceed 20- pounds water capacity. Aggregate capacity shall not exceed 60-pound water capacity. Each device shall be separated from other container by a distance of not less than 20 feet. 86. Section 3804.2; Maximum capacity within established limits, International Fire Code, amended to read as follows: 3804.2; Maximum capacity within established limits. The limits referred to in Section 3804.2; International Fire Code, amended to read as follows: Bulk storage of liquefied Petroleum Gas (LPG), is restricted in all heavily populated and congested commercial areas of the City. 87. Section 3804.3.2; Maximum capacity within established limits, International Fire Code, The limits referred to in added Section 3804.3.2, Spas and Pool Heaters, is established and reads: Where natural gas service is not available within 300 feet of the site, LP-Gas containers are allowed to be used to supply spa and pool heaters. Such containers shall not exceed 250-gallon water capacity. Sec. 8. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-35; Uniform Fire Code - Appeals, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46-35; Appeals. Whenever the Code Official disapproves or refuses to grant a permit applied for, or when it is claimed that the provision of the code adopted in Section 46.31, International Fire Code, does not apply or that the true intent and meaning of the code adopted in Section 46.31, International Fire Code, have been misconstrued or wrongly interpreted, the person that applied for the permit may appeal from the decision of the Code Official to the City of Colleyville Contractor's Board within 30 days from the date of the Code Official decision. Ordinance 0-02-1348 Page 29 of 34 Sec. 9. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-36; Uniform Fire Code - Establishment of limits of districts in which storage of flammable or combustible liquids is prohibited, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46-36; Establishment of limits of districts in which storage of flammable or combustible liquids is prohibited. The storage of flammable or combustible liquids in an outside above ground storage is prohibited. Exceptions: a. An exception may be granted by the Fire Marshal during an emergency operation, at construction sites, and other locations where underground installations cannot be utilized. At no time will the sale or distribution of flammable or combustible liquids be allowed from above ground storage tanks by gravity, portable pump powered by vehicle batteries or pneumatic pressure. b. Above ground fuel tanks that comply with International Fire Code, Chapter 34, may be allowed for commercial and retail purposes when permitted by the Fire Marshal. c. The storage of flammable or combustible liquids at construction sites shall require a permit from the Fire Marshal's office. All fuel tanks shall be at least ten (10) feet off the roadway. Sec. 10. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-37; Uniform Fire Code - Establishment of limits of districts in which storage of explosives and blasting agents is prohibited, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46-37; Establishment of limits of districts in which storage of explosives and blasting agents is prohibited: a. The storage of explosives or blasting agents within the city limits is prohibited without a permit from the Fire Marshal. b. No motor vehicle designed or utilized to transport explosives or blasting agents, or required a Department of Transportation (DOT) warning placards, shall be Ordinance 0-02-1348 Page 30 of 34 parked within the city limits without a Fire Marshals' permit. Exception: Vehicles may be parked for one (1) hour for the purpose of loading or off loading cargo or eating a meal. Sec. 11. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-38; Uniform Fire Code - Establishment of limits in which bulk storage of liquefied petroleum gases is restricted, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46-38; Establishment of limits in which bulk storage of liquefied petroleum gases is restricted. a. The storage, sale, and distribution of Liquefied Petroleum Gas (LPG) prohibited in all heavily populated and congested commercial areas of the city. b. The storage, sale, and distribution or installation of liquefied Petroleum Gas (LPG) systems on vehicles shall meet the regulations and guidelines of the Texas Railroad Commission, Chapter 38 of the International Fire Code, NFPA 58, and the International Fuel Gas Code. c. The storage, sale, and distribution of Liquefied Petroleum Gas (LPG) must have a permit from the Fire Marshal. d. A permit shall be required for the installation, alteration and/or removal of a Liquefied Petroleum Gas (LPG) tank. The permit shall be obtained before the start of any work and the cost of the permit shall be by the Fee Schedule of the Code of Ordinance, City of Colleyville, Texas. e. Where portable liquefied Petroleum gas (LPG) containers are required for jewelry repair, dental labs, portable cookers and other services, individual containers shall not exceed 20-pound water capacity and the aggregate capaCity on premises shall not exceed 60 pounds water capacity (3 containers). Each container shall be separated from other containers by a distance of not less than twenty (20) feet. Exception: Such events where commercial outdoor cooking is required, provided a permit is issued by the Fire Marshals' office and the site is inspected by the Code Official. 46-38.1; establishing a standard and limits for Compressed Natural Gas (CNG). Ordinance 0-02-1348 Page 31 of 34 a. The storage of Compressed Natural Gas (CNG) is prohibited in all heavily populated and congested commercial areas of the city. b. The storage, sale, distribution or installation of vehicular fuel systems on vehicles shall be in accordance with the International Fuel Gas Code, NFPA 52, and related standard and regulation of the International Fire Code, and the International Fuel Gas Code. c. The storage, sale, distribution, removal, alteration or modification of a Compressed Natural Gas (CNG) must have a site inspection before the work begins d. A permit is required from the Fire Marshals' office. Section 46.38.2; Liquefied Natural Gas (LNG), Establishing a standard and limits for Liquefied Natural Gas (LNG) a. The storage of liquefied Natural Gas (LNG) is prohibited in all heavily populated and congested commercial areas of the city. b. The storage, sale, distribution, or installation of a vehicular fuel system shall be in accordance with the International Fuel Gas Code, Texas Railroad Commission, NFPA 55, NFPA 57, and related Chapters of the International Fire Code. c. Any storage, sale, distribution, shall require a permit from the Fire Marshal's office. Sec. 12. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-39; New Materials, processes or occupancies which may require permits, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46-39; New materials, processes or occupancies which may require permits. The Fire Chief, Fire Marshal and the Building Official shall act as a committee to determine and specify, after giving affected persons an opportunity to be heard, and new materials, processes or occupancies for which permits are required. The committee shall review codes adopted to determine if the product meets or exceeds the code standards. The Fire Marshal shall post such materials listing in a conspicuous place at the office of the Fire Administration and distribute copies thereof to interested persons. Ordinance 0-02-1348 Page 32 of 34 Sec. 13. THAT, Chapter 46, Fire Prevention and Protection, Article II Fire Code, Section 46-40; Penalties, is hereby repealed in its entirety and a new section shall be added to read as follows: Section 46-40; Penalties, Any person, firm or corporation violating any of the provisions of this code shall be fined as provided for in Section 1-6 of the Code of Ordinance, City of Colleyville, Texas. Now, be it known that Section 46 of the Code of Ordinance, City of Colleyville, Texas, shall remain in full force and effect, except where amended by this ordinance, and That any person, firm, or corporation violating any of the provisions of this ordinance shall be guilty of a misdemeanor and upon conviction thereof shall be fined a sum not to exceed Two Thousand Dollars ($2,000.00). Each and every day such violation continues shall constitute a separate offense and shall be punishable as such. Sec. 14. That the City Secretary is hereby authorized and directed to cause publication of the descriptive caption and penalty clause hereof as an alternative method of publication provided by law. THAT, Chapter 22, Business, Section 22-1; Fire protection equipment services and contractors (b) Fee Schedule is hereby repealed in its entirety and a new section shall be added to read as follows: (b) Fee Schedule: Permit Description Fee Hazardous Materials Vehicle (Required to have DOT $ 50.00 Placard) Security Gates (Required 3 set of detail plans) $ 50.00 Plus $25.00 oer reauired sian. Storage of Flammable or Combustible Liquids at $ 50.00 Construction Sites Installation of Compressed Natural Gas (CNG) Container $ 50.00 or Stations Removal, relocation of Compressed Natural Gas (CNG) $ 50.00 Container or Station Ordinance 0-02-1348 Page 33 of 34 Installation of li uid Petroleum Gas LPG Container Removal, relocation of Liquid Petroleum Gas (LPG) Container Installation of liquefied Natural Gas (LNG) Container or Station Removal, relocation of liquefied Natural Gas (LNG) Container or Station Fire Alarm New 3 sets of detailed lans Fire Alarm Alteration or relocation 3 sets of detailed lans Fixed Fire Protection System (New) 3 sets of detailed lans Fixed Fire Protection System (Alteration or relocation) 3 sets of detailed lans Fire Sprinkler System (New) 3 sets of detailed plans - Above round 1 to 50 heads 51 to 500 Heads 500 Heads and over Fire Sprinkler System (Relocation or modification) 3 sets of detailed lans - Under round a. Inspection is required before ditch is $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 100.00 $ 150.00 $ 200.00 covered $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 100.00 $ 100.00 $ 50.00 Storage $ 50.00 $ 50.00 $ 50.00 $ 100.00 $ 50.00 $ 25.00 AND IT IS SO ORDERED. Ordinance 0-02-1348 Page 34 of 34 The first reading and public hearing being conducted on the /8/1 day of r 2002. the second reading and public hearing being conducted on the c;2.:(,~day of ~ 2002. ATTEST: cf1~~ Cynthia Singleton, TRMC City Secretary AS TO FORM AND LEGALITY: CITY OF COLLEYVILLE ~~ Mayor