HomeMy WebLinkAboutPlanning and Zoning Commission-Agenda Packets-2/10/2025
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING
COMMISSION AGENDA
100 Main Street Colleyville, Texas 76034
MONDAY, FEBRUARY 10, 2025
PRE COMMISSION MEETING
6:15 P.M.
EXECUTIVE CONFERENCE ROOM
THIRD FLOOR
LEGAL BRIEFING BY CITY ATTORNEY REGARDING PLANNING, ZONING,
PLATTING, AND LAND USE
REVIEW OF REGULAR AGENDA ITEMS AND DISCUSSION OF PREVIOUS
MEETING MINUTES
DISCUSSION OF ITEMS TO BE PLACED ON FUTURE AGENDAS AND UPDATES
ON DEVELOPMENT TRENDS, PROGRESS AND CITY COUNCIL ACTIONS ON
PAST AGENDA ITEMS
EXECUTIVE SESSION – In accordance with Texas Government Code Chapter
551, Subchapter D, Section 551.071 – Legal – Consultation with attorney
on legal issues raised by public hearing or action items on the agenda
7:00 P.M. - REGULAR MEETING
CALL TO ORDER AND ROLL
INVOCATION: Brandon Arnold
PLEDGE OF ALLEGIANCE
1. APPROVAL OF MINUTES
1a January 13, 2025 Planning and Zoning Commission Minutes
January 27, 2025 Planning and Zoning Worksession Minutes
2. PUBLIC HEARING AGENDA ITEMS
2a Consideration of a Special Use Permit to allow for a Warehouse and
Distribution Facilities use on Tracts 2G, 2H, and 2J, Abstract 963,
Absalom J Lott Survey, and Lot 1, Block 1, Konyha Addition, being
located at 6600, 6602, 6604, and 6526 Colleyville Boulevard, Case
ZC24-025 THE ITEM HAS BEEN WITHDRAWN BY THE APPLICANT
Planning and Zoning Commission Agenda February 10, 2025
City of Colleyville Page 2
2b Consideration of a replat for Lot 1R-1-A, Block 1, First Baptist Church
of Colleyville Addition, being Lots 1 and 2, Block 1, Garden Addition;
Lot 1, Block 1, H.E.C. Addition; Lots 1R-1 and 2, Block 1, First Baptist
Church of Colleyville Addition; and Tracts 1C and 1C03, Abstract 936,
Joseph M. Looney Survey, located at 5300 Colleyville Boulevard, 1007
Church Street, and 5312, 5313, 5405, and 5505 Pleasant Run
Road, Case PC25-002
2c Consideration of a rezoning from AG Agricultural to R-30 Single Family
Residential and R-40 Single Family Residential districts on Tracts 4A2
and 4B2, 4A3 and 4B3, Abstract 295, William E. Crooks Survey, being
located at 7316 and 116 John McCain Road, Case ZC25-001
2d Consideration of a change to the Land Development Code, Chapter 3,
Section 3.27, Accessory Building Regulations and Residential Carport
Regulations
3. CITIZEN COMMENTS
4. ADJOURNMENT
I hereby certify this agenda was posted on City Hall bulletin boards Thursday, February 6,
2025, by 5:00 p.m.
Jacquelyn Reyff
Planning Manager
A quorum of any Colleyville board, commission, or committee may be present at this
meeting. Any matter on this agenda may, at the discretion of the governing body, be
opened for public comment and discussion.
If you plan to attend this public meeting and have a disability that requires special
accommodations, please advise the City Secretary at least 48 hours in advance at
817.503.1133, and reasonable accommodations will be made to assist you.
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
BRIEFING
Agenda Number 1a Agenda Date 2/10/2025 Number -
Type Approval of Minutes
Department Community Development
Title
January 13, 2025 Planning and Zoning Commission Minutes
January 27, 2025 Planning and Zoning Worksession Minutes
Explanation
This item provides for the approval of the minutes from the January 12, 2025 Planning
and Zoning Commission meeting and the January 27, 2025 Planning and Zoning
Commission Worksession meeting.
Recommendation
Approve
Attachments
1. January 13, 2025 Planning and Zoning Commisison Meeting Minutes
2. January 27, 2025 Planning and Zoning Commission Worksession Minutes
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING
COMMISSION MINUTES
100 Main Street, Colleyville, Texas, 76034
MONDAY, JANUARY 13, 2025
CALL MEETING TO ORDER
EXECUTIVE CONFERENCE ROOM
The City of Colleyville Planning and Zoning Commission Worksession Meeting was
called to order by Chair Bevill on January 13, 2025 at 6:15 p.m.
Roll Call
Present: Richard Remley, David Ebert, Jerome Obinabo, Brandon Arnold, Jerry
Savoie, and Claudia Bevill
Absent: David Groves
Staff Present: Ben Bryner, Jacquelyn Reyff, Kristopher Potts, and Christopher Pham
Also Present: Attorney, Sarah Ross, Fire Marshal, Rob Mckeown
City staff briefed the Commission on the items that would be presented on tonight’s
agenda. There was general discussion amongst the updates to the case the
Commission would be voting on.
The Commission had questions about case ZC24-006, specifically regarding
language in the ordinance that would prevent residential uses and whether the units
would be rented or sold.
Chair Bevill adjourned the Planning and Zoning Commission Wor ksession Meeting at
6:41 p.m.
CALL MEETING TO ORDER
EXECUTIVE CONFERENCE ROOM
The City of Colleyville Planning and Zoning Commission Meeting was called to order
by Chair Bevill on January 13, 2025, at 7:08 p.m.
Planning and Zoning Commission Minutes January 13, 2025
City of Colleyville Page 2
Roll Call
Present: Richard Remley, David Ebert, Jerome Obinabo, Brandon Arnold, Jerry
Savoie, and Claudia Bevill
Absent: David Groves
Staff Present: Ben Bryner, Jacquelyn Reyff, Kristopher Potts, and Christopher Pham
Also Present: Attorney, Sarah Ross, Fire Marshal, Rob Mckeown
1. ELECTION OF OFFICERS
1a Election of Chair and Vice-Chair of the Planning and Zoning Commission
Commissioner Savoie made a motion to elect Commissioner Bevill as Chair
of the Planning and Zoning Commission.
Commissioner Remley seconded the motion.
The motion was carried by the following vote:
Aye: 5 – Remley, Ebert, Obinabo, Arnold, and Savoie
Nay: 0
Abstain: 1 – Bevill
Commissioner Remley made a motion to elect Commissioner Groves as
Vice-Chair of the Planning and Zoning Commission.
Commissioner Obinabo seconded the motion.
Aye: 6 – Remley, Ebert, Obinabo, Arnold, Savoie, and Bevill
Nay: 0
2. APPROVAL OF MINUTES
2a December 9, 2024 Planning and Zoning Commission Meeting Minutes
December 23, 2024 Planning and Zoning Commission Worksession
Planning and Zoning Commission Minutes January 13, 2025
City of Colleyville Page 3
Meeting Minutes
Commissioner Remley made a motion to approve the December 9, 2024
Planning and Zoning Commission Meeting Minutes and the December 23,
2024 Planning and Zoning Worksession meeting minutes with corrections.
Commissioner Arnold seconded the motion.
The motion was carried by the following vote:
Aye: 6 – Remley, Ebert, Obinabo, Arnold, Savoie, and Bevill
Nay: 0
3. PUBLIC HEARING AGENDA ITEMS
3a Consideration of a rezoning from CC-1 Village Retail and PUD-C Planned
Unit Development – Commercial to PUD-C Planned Unit Development –
Commercial on Lot 1, Block 1, Tinker Crossing Addition, Lot 1A, Block 1,
Kathleen’s Art Café Addition, and Lot R14-3, Block 1, Colleyville Industrial
Park, located at 1801 Industrial Boulevard and 6255 and 6301 Colleyville
Boulevard, ZC24-006
Christopher Pham presented case ZC24-006 and briefed the Commission. The
request is to allow for a new PUD to be created which would allow for a ‘luxury
garage’ development to be built.
The applicant, Skye Thibodeaux, came forward to address concerns the Commission
had in their worksession discussion. He stated that there would be a Property
Owners Association for garage unit owners and that the garages would be
personalized, which would allow for owners to add features such as bathrooms if
they saw fit. He also let the Commission know that with adjustments to the site plan,
the open space percentage would be between 20%-22% and that underground
detention would be provided.
The public hearing was opened at 7:43 p.m.
The following citizens did not wish to speak, but did wish to record their opposition:
Karen Gahan, 1905 Fountain Pass Drive
Planning and Zoning Commission Minutes January 13, 2025
City of Colleyville Page 4
Norma Tacconi, 1617 Fountain Pass Drive
Eugenio Tacconi, 1617 Fountain Pass Drive
Cathy Mielke, 1901 Fountain Pass Drive, spoke in opposition, specifically regarding
concerns with the development’s effects on property value, quality of landscaping
and buffer zones, the height of masonry screening, noise control measures, building
height, privacy concerns due to the placement of high windows on the exterior of
the buildings, and whether the property would be sold as units or rented.
Mary Dede, 1717 Rock Dove Circle, spoke in opposition, specifically regarding the
number of luxury garages in nearby communities, traffic impact on their subdivision
entrance, the desirability of garage and storage units adjacent to Colleyville
Boulevard, and concerns whether the units would be sold or leased.
Barbara Shea, 6108 Brazos Court, spoke in support, stating that luxury garages are
more desirable than additional self-storage. She did have concerns regarding traffic
impact and the impact of the development on Oak Pointe Drive.
Robert Brown, 1407 Savoy Ct, spoke neutrally, specifically regarding concerns of
increased drainage impact on the Monterra Subdivision from this development.
With no one wishing to speak, the public hearing was closed at 8:08 p.m.
The applicant, Skye Thibodeaux, came forward to address resident concerns. He
stated that drainage would be accounted for as part of the development and that
the neighborhood privacy would be respected as the high windows would be for light
and would not be usable for garage owners to look out of. He stated that the number
of entrances to the development was controlled by TXDOT.
The Commissioners discussed amongst themselves regarding their concerns.
Commissioners Obinabo and Remley made the recommendation that the case should
be tabled to provide updated exhibits that addressed neighbor concerns. Chair Bevill
made recommendations that the units should be sold, rather than leased, and that
the reflection of the glass garage doors could cause nuisances to nearby neighbors.
She recommended that frosted film be added to the glass and that the overall
building height should be reduced.
Commissioner Obinabo made a motion to table case ZC24-006 to the March
10, 2025 Planning & Zoning Commission Meeting.
Commissioner Remley seconded the motion.
Planning and Zoning Commission Minutes January 13, 2025
City of Colleyville Page 5
The motion was carried by the following vote:
Aye: 6 –Remley, Ebert, Obinabo, Arnold, Savoie, and Bevill
Nay: 0
3b Consideration of a Special Use Permit to allow for a Warehouse and Distribution Facilities use on Tracts 2G, 2H, and 2J, Abstract 963, Absalom J Lott Survey, and Lot 1, Block 1, Konyha Addition, being located at 6600, 6602, 6604, and 6526 Colleyville Boulevard, Case ZC24-025
REQUEST TO TABLE BY APPLICANT TO FEBRUARY 10, 2025 PLANNING
Commissioner Obinabo made a motion to table Case ZC24-024 to the
February 10, 2025 Planning and Zoning Commission Meeting.
Commissioner Ebert seconded the motion.
The motion was carried by the following vote:
Aye: 6 –Remley, Ebert, Obinabo, Arnold, Savoie, and Bevill Nay: 0
3c Consideration of a Special Use Permit to allow for a Veterinarian Clinic to
operate out of an existing dog grooming and boarding center on Lot 5,
Block 1, Colleyville Industrial Park, being located at 1808 Industrial
Boulevard, Case ZC24-030
Kris Potts presented case ZC24-030 and briefed the Commission on the request. The
request is to allow a veterinarian clinic, Vetted, to operate out of an existing pet
grooming and boarding facility.
The applicant, Melissa Preston, 1802 Baylia Lane, Spring Hill, TN, 37174 came
forward to let the Commission know she was available for any questions.
The public hearing was opened at 8:38 p.m.
With no one wishing to speak, the public hearing was closed at 8:38 p.m.
Commissioner Bevill made a motion to approve case ZC24-030.
Commissioner Obinabo seconded the motion.
Planning and Zoning Commission Minutes January 13, 2025
City of Colleyville Page 6
The motion was carried by the following vote:
Aye: 6 –Remley, Ebert, Obinabo, Arnold, Savoie, and Bevill Nay: 0
3d Consideration of a rezoning from PUD-C Planned Unit Development –
Commercial to PUD-C Planned Unit Development – Commercial on Tract 2A
and a portion of an abandoned street, Abstract 963, Absalom J. Lott Survey,
being located at 6521 Colleyville Boulevard, Case ZC24-031
Jacquelyn Reyff presented case ZC24-031 and briefed the Commission on the
rezoning request. The request is for a new office-warehouse development.
Girish Narayn, 4721 Memphis St, Dallas, TX, 75207, the applicant, presented the
request and read a letter he received in support from Ken Green, 7205 Vanguard
Court.
The public hearing was opened at 8:52 p.m.
Greg Flowers, 6614 McMakin Court, spoke in support of the development, specifically
regarding the aesthetics of the development and drainage improvements. He did
have a concern regarding traffic increasing as a result of the development.
Scott Knepper, 2009 Tarrant Lane, spoke neutrally on the development, stating that
traffic would increase as a result of the development and that Tarrant Lane would
see increasing usage as a thoroughfare.
Dave Dudziak, 2301 Wilkes Court, spoke in support of the item, stating that the
improvements to the site and maintenance were improvements from the current
state, however he did have concerns regarding traffic impact.
With no one wishing to speak, the public hearing was closed at 9:05 p.m.
The applicant, Girish Narayan, spoke in regards to traffic concerns. He stated that a
full traffic study was requested and that a median break was proposed to TXDOT,
who would have to approve the median break. Wilson Bauer spoke on the existing
use as Hodges Automotive and the number of trips generated from that business.
The Commission had discussion amongst themselves on whether a traffic study
could be added as a condition of an approval and how traffic on Colleyville Boulevard
would increase regardless of the approval of this development.
Planning and Zoning Commission Minutes January 13, 2025
City of Colleyville Page 7
Commissioner Savoie made a motion to approve case ZC24-031.
Commissioner Ebert seconded the motion.
The motion was carried by the following vote:
Aye: 6 – Remley, Ebert, Obinabo, Arnold, Savoie, and Bevill
Nay: 0
4. CITIZEN COMMENTS
The public forum opened at 9:20 p.m.
With no one wishing to speak, the public forum closed at 9:20 p.m.
5. ADJOURNMENT
The meeting adjourned at 9:21 p.m.
The minutes were written and prepared by:
Christopher Pham
Christopher Pham
Planner
The meeting minutes were approved on February 10, 2025 by a vote of X-X.
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING
COMMISSION WORKSESSION
MINUTES
100 Main Street, Colleyville, Texas, 76034
JANUARY 27, 2025
CALL MEETING TO ORDER
EXECUTIVE CONFERENCE ROOM
The City of Colleyville Planning and Zoning Commission Worksession Meeting was
called to order by Chair Bevill on January 27, 2025, at 6:16 p.m.
Roll Call
Present: Claudia Bevill, Jerry Savoie, David Ebert, Richard Remley, Jerome
Obinabo, and Brandon Arnold
Absent: David Groves
Staff Present: Ben Bryner, Jacquelyn Reyff, Chris Pham, and Kris Potts
Also Present: Fire Marshal, Rob Mckeown, and Attorney, Sarah Ross
2. WORKSESSION AGENDA ITMES
2a Presentation and discussion of a replat for Lot 1R-1-A, Block 1, First
Baptist Church of Colleyville Addition, being Lots 1 and 2, Block 1, Garden
Addition; Lot 1, Block 1, H.E.C. Addition; Lots 1R-1 and 2, Block 1, First
Baptist Church of Colleyville Addition; and Tracts 1C and 1C03, Abstract
936, Joseph M. Looney Survey, located at 5300 Colleyville Boulevard,
1007 Church Street, and 5312, 5313, 5405, and 5505 Pleasant Run Road,
Case PC25-002
Chris Pham presented the case and briefed the Commission on the replat request.
The request is to combine the lots of the Crosscreek Church Campus into one lot for
future development efforts.
2b Presentation and discussion of a rezoning from AG Agricultural to R-30
Single-Family Residential and R-40 Single-Family Residential districts on
Planning and Zoning Commission Worksession
Minutes January 27, 2025
City of Colleyville Page 2
Tracts 4A2 and 4B2, 4A3 and 4B3, Abstract 295, William E. Crooks Survey,
being located at 7316 and 116 John McCain Road, Case ZC25-001
Kris Potts briefed the Commission on the rezoning request. There was discussion
regarding the number of lots that were allowed on a single access point cul-de-sac,
and whether an emergency access easement on the southeast most lots would be
beneficial for the development and neighbors or not. Staff informed the Commission
that a second point of ingress and egress was required when a development
proposes over 12 lots, but that the Land Development Code sets a maximum of 10
lots on a cul-de-sac. The Commission inquired about the reason the Land
Development Code establishes a limit on the number of lots.
2c Presentation and discussion of a change to the Land Development Code,
Chapter 3, Section 3.27, Accessory Building Regulations and Residential
Carport Regulations
Ben Bryner briefed the Commission on the Land Development Code Amendment.
The Commission inquired if a checklist or application with all the information
presented might be beneficial to carport applicants. Staff stated that applicants
normally talk to the city prior to applying for a carport, and that staff would provide
that information.
3. ADJOURMENT
The meeting adjourned at 6:39 p.m.
The minutes were written and prepared by:
Christopher Pham
Planner
The meeting minutes were approved on February 10th, 2025 by a vote of x-x.
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
BRIEFING
Agenda Number 2a Agenda Date 2/10/2025 Number -
Type Public Hearing Agenda Items
Department Community Development
Title
Consideration of a Special Use Permit to allow for a Warehouse and Distribution
Facilities use on Tracts 2G, 2H, and 2J, Abstract 963, Absalom J Lott Survey, and Lot 1,
Block 1, Konyha Addition, being located at 6600, 6602, 6604, and 6526 Colleyville
Boulevard, Case ZC24-025 THE ITEM HAS BEEN WITHDRAWN BY THE APPLICANT
Explanation
THE ITEM HAS BEEN WITHDRAWN BY THE APPLICANT
Sarah Politiski, the applicant, has submitted a request for a Special Use Permit (SUP) for
a Warehouse and Distribution Facility on Tracts 2G, 2H, and 2J, Abstract 963, Absalom J
Lott Survey, and Lot 1, Block 1, Konyha Addition, being approximately 8.60 acres, and
zoned ML Light Manufacturing. Warehouse and Distribution Facilities are only allowed in
the ML Light Manufacturing zoning district with the approval of a Special Use Permit
(SUP). The request is to allow for the development of a new 149,600 square foot
distribution warehouse to be built.
Existing Conditions/Background: The subject properties, 6600, 6602, 6604, and
6526 Colleyville Boulevard, are zoned ML Light Manufacturing and located southwest of
the intersection of Colleyville Boulevard and Tennison Parkway. The property at 6604
Colleyville Boulevard is currently undeveloped. The properties at 6600, 6602, and 6526
Colleyville Boulevard are developed with contractor offices with storage yards.
SUP Request: The applicant is requesting approval of an SUP to allow for a Warehouse
and Distribution Facility. The property is zoned ML Light Manufacturing which allows for
a warehouse and distribution facility with approval of an SUP.
Special Use Permit Provision: Any request for Warehouse and Distribution Facilities
shall only be authorized after approval of an SUP by the City Council using the
procedures contained elsewhere in this Land Development Code.
Analysis: Per the attached Site Plan Exhibit, the proposed development will offer a new
149,600 square foot warehouse and distribution facility. The warehouse will be 1-story
and is 32-feet in height. Including the parapet walls, the total height proposed is
approximately 45 feet. As per the building elevations, the warehouse facility will have
43 loading doors on the south side of the building. As part of the SUP request, the
applicant is requesting a reduction in masonry materials from 90% to 22%. A 26-foot
fire lane will extend around the entire facility. 150 parking spaces will be provided.
City of Colleyville Page 2
Planning and Zoning
Commission
Agenda Briefing 2a
The development will offer 20% of landscaped open space area, totaling 77,491 s.f. A
50-foot landscape buffer will be provided from Colleyville Boulevard, and an 8-foot wall
will be provided to screen the loading dock bay adjacent to Colleyville Boulevard. A 20-
foot landscape buffer and an 8-foot masonry screening wall will also be provided
adjacent to residential development on the north and west sides of the site.
Plat Status: A portion of the property is unplatted as Tracts 2G, 2H, and 2J, Abstract
963, Absalom J Lott Survey. A portion of the property is platted as Lot 1, Block 1,
Konyha Addition.
DRC Review: The DRC reviewed the request and offered the following comments.
1. The building needs to meet the design requirements of Chapter 6 of the Land
Development Code. Vertical articulation does not appear to be met.
2. How tall will the masonry screening wall be? The minimum height required by the
Land Development Code is 8 feet.
3. The building is too tall for the zoning district. Maximum building height cannot go
beyond 35 feet.
4. Provide traffic generation calculations to determine if traffic impact analysis is
required.
5. Informational note: Please provide information on whether high-pile storage will
occur at this site.
6. TXDOT permit is required for work in the R.O.W. of Colleyville Boulevard.
7. Engineering Comments: Refer to marked PDF attached for Engineering
comments.
Drainage: As per the applicant’s drainage plan, this development is proposing to
enclose the existing Pecan Creek that crosses through the property within a proposed 3-
10’x 8’ reinforced concrete box storm system that wraps around the proposed building.
Stormwater modeling will be required downstream and upstream of the property under
pre- and post- development conditions to prove there is no increase in drainage flow or
water surface elevation under multiple storm events up to the 100-year storm event.
Wetlands delineation and/or mitigation is also required for the existing Pecan Creek that
is proposed to be removed. There will be City, FEMA and Army Corps of Engineering
reviews and approvals required for this proposed drainage design.
Surrounding Development: The properties to the north and west are zoned PUD-R
Planned Unit Development – Residential and are improved with single-family homes.
The properties to the east are Colleyville Boulevard and a lot that is zoned CC-1 Village
Retail and improved with a commercial retail and medical office building. The property
City of Colleyville Page 3
Planning and Zoning
Commission
Agenda Briefing 2a
to the south is zoned ML Light Industrial and improved with a contractor office with
storage buildings.
Comprehensive Plan: The City’s comprehensive plan, Destination Colleyville, identifies
the subject property for commercial development and as part of the Colleyville
Boulevard Corridor. The proposed development does not conflict with the
Comprehensive Plan.
Public Notification: Staff mailed notices to all property owners within 500 feet as well
as any Homeowners Associations within 1000 feet of the subject property regarding this
request. Grapevine-Colleyville ISD, where the subject property is located, was notified
per State law. Notice was published in the Fort Worth Star-Telegram as required by
State law and the Land Development Code.
Staff Recommendation: Staff is neutral on this request.
Recommendation
None
Attachments
1. Withdrawal Letter
From:James Yu
To:Jackie Reyff
Cc:Bennett See; Chris Gilbert
Subject:Zoning Case ZC24-025 Colleyville
Date:Tuesday, January 28, 2025 1:45:56 PM
Jackie:
I wanted to let you know that we have decided not to pursue the zoning change on this
site. Appreciate working with you and the city staff on this project. Thank you.
James Yu, P.E.
Development Manager
LOVETT
INDUSTRIAL
3811 Turtle Creek Blvd
Suite #1050
Dallas, TX 75219
972-489-5570 (m)
www.lovettindustrial.com
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
BRIEFING
Agenda Number 2b Agenda Date 2/10/2025 Number -
Type Public Hearing Agenda Items
Department Community Development
Title
Consideration of a replat for Lot 1R-1-A, Block 1, First Baptist Church of Colleyville
Addition, being Lots 1 and 2, Block 1, Garden Addition; Lot 1, Block 1, H.E.C. Addition;
Lots 1R-1 and 2, Block 1, First Baptist Church of Colleyville Addition; and Tracts 1C and
1C03, Abstract 936, Joseph M. Looney Survey, located at 5300 Colleyville Boulevard,
1007 Church Street, and 5312, 5313, 5405, and 5505 Pleasant Run Road, Case PC25-
002
Explanation
Zach Towery, the applicant, has submitted a request for a Replat for Lot 1R-1-A, Block
1, First Baptist Church of Colleyville Addition, being Lots 1 and 2, Block 1, Garden
Addition; Lot 1, Block 1, H.E.C. Addition; Lots 1R-1 and 2, Block 1, First Baptist Church
of Colleyville Addition; and Tracts 1C and Tract 1C03, Abstract 936, Joseph M. Looney
Survey; being approximately 20.09 acres; and zoned CC-1 Village Retail. The purpose is
to allow for the Crosscreek Church Campus to be platted together as one lot.
Existing Conditions/Background: The subject properties, 5300 Colleyville Boulevard,
1007 Church Street, and 5312, 5313, 5405, and 5505 Pleasant Run Road, are generally
located southwest of the intersection of Colleyville Boulevard and Church Street. The
properties in their current configuration are broken up into seven individual lots located
along Pleasant Run Road, Church Street, and Colleyville Boulevard. 5300 Colleyville
Boulevard, 1007 Church Street, and 5312, 5313, and 5405 Pleasant Run Road are
improved with the Crosscreek Church Campus and related parking. 5505 Pleasant Run
Road is undeveloped.
Lot Dimensions and Setbacks: The applicant requests to replat the properties into
one lot within the CC-1 Village Retail district. The minimum standards for the CC-1
zoning district are as follows:
Minimum Lot Size 15,000 sf.
Minimum Lot Width 150 feet
Minimum Lot Depth 120 feet
Front Building Line 40 feet
Side Building Line 15 feet
Rear Building Line 10 feet
Max. Lot Coverage 50%
Max. Impervious Coverage 80%
City of Colleyville Page 2
Planning and Zoning
Commission
Agenda Briefing 2b
Surrounding Development: The properties to the north are zoned AG Agricultural and
improved with religious institutional buildings. The properties located to the west are
zoned R-10 Single-Family Residential, R-30 Single-Family Residential, and PUD-R
Planned Unit Development – Residential and improved with single-family homes. There
is also a CN Neighborhood Commercial lot that is improved with an office building. The
properties to the south are zoned PUD-C Planned Unit Development – Commercial and
AG Agricultural. The PUD-C property is located in The Village and improved with
commercial and residential uses in a mixed-use setting. The AG lots are improved with
single-family homes.
Analysis: The purpose of the replat is to combine the Crosscreek Church Campus into
one lot. The replat will allow for future development efforts to occur, as open space and
impervious coverage will be calculated using the entire land area owned by the church
rather than individual lots. The lot will comply with the CC-1 Village Retail regulations. A
variable amount of right-of-way will be dedicated to the city along Pleasant Run Road. A
floodplain easement will be notated on the plat to indicate the portions of the property
located in floodplain.
Plat Status: Sections of the property are platted and sections are unplatted. The
platted lots are Lots 1 and 2, Block 1, Garden Addition; Lot 1, Block 1, H.E.C. Addition;
and Lots 1R-1 and 2, Block 1, First Baptist Church of Colleyville Addition. The unplatted
lots are Tracts 1C and Tract 1C03, Abstract 963, Joseph M. Looney Survey.
DRC Review: The Development Review Committee (DRC) reviewed this request during
their January 20, 2025 meeting and offered the following comments to the applicant:
1. Provide a 7.5’ drainage and utility easement along the southern most property line
running to the East to the creek and along the property located at 1009 Church
Street.
2. Provide a flood plain easement.
3. Indicate on the plat for the edge of parking along Pleasant Run Road a straight
line showing the number of feet where the church property line ends and the city
sidewalk begins.
Tree Preservation: Any subdivision of the subject property must comply with Chapter
5 (Tree Preservation) of the Land Development Code. Where any tree is slated for
removal, no site grading, dirt disturbance or new construction may occur on the
property until a Tree Removal Permit has been issued that is associated with an
approved Tree Preservation Plan.
In addition to the requirements for submittal of a Tree Removal Permit and Tree
Preservation Plan, future development on the site must maintain the minimum existing
City of Colleyville Page 3
Planning and Zoning
Commission
Agenda Briefing 2b
protected tree canopy coverage as required in Chapter 5.
Public Notification: Staff mailed notices to all property owners within 500 feet as well
as any Homeowners Associations within 1,000 feet of the subject property regarding this
request. Grapevine-Colleyville ISD, where the subject property is located, was notified
per State law. Notice was published in the Fort Worth Star-Telegram as required by
State law and the Land Development Code.
Staff Recommendation: Staff recommends approval of the replat.
Recommendation
Approve
Attachments
1. Aerial Map
2. Zoning Map
3. Future Land Use Map
4. Plat Exhibit
5. Notification Map
6. Notification Letter
7. Notification List
8. Draft Resolution
H
A
L
LJOHNSON RD
PLEASANT RUN RDMAIN ST COLLEYVILLE BLVDCH
U
R
C
H
S
T
COTTAGE LNVILLAGELNC A S A LN
PIAZZA LNSOUTHDR RIVERWALKDRLAUREL OAKS LN
COLLEYVILLE TERR
FIELD ST
HILLSIDE RD
NUECES CT
V E R A N D A LN
MISSIONLNREGINA CT
HID DE N OA K S CT
DOGWOOD CT
THOMAS ST
C E N T R A L DR
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC24-010
5300 Colleyville Blvd
Aerial Map
H
A
L
LJOHNSON RD
PLEASANT RUN RDCOLLEYVILLE BLVDCH
U
R
C
H
S
T
COTTAGE LNVILLAGE LNC A S A LN
PIAZZA LNSOUTHDRMAINST RIVERWALKDRLAUREL OAKS LN
COLLEYVILLE TERR
FIELD ST
HILLSIDE RD
NUECES CT
V E R A N D A LN
MISSIONLNREGINA CT
HID DE N OA K S CT
DOGWOOD CT
THOMAS ST
C E N T R A L DR
R-20
CN
AG
CC-1CC-1
CPO
R-10
R-10
R-10
CC-1
CC-1
PUD-C
PUD-C
AG
CNR-20 CC-1
PUD-R
PUD-R
CN PUD-C
R-20
CC-2
RE
CC-1
PUD-C
AG
R-20
R-30
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC24-010
5300 Colleyville Blvd
Zoning Map
H
A
L
LJOHNSON RD
PLEASANT RUN RDMAIN ST COLLEYVILLE BLVDCH
U
R
C
H
S
T
COTTAGE LNVILLAGELNC A S A LN
PIAZZA LNSOUTHDR RIVERWALKDRLAUREL OAKS LN
COLLEYVILLE TERR
FIELD ST
HILLSIDE RD
NUECES CT
V E R A N D A LN
MISSIONLNREGINA CT
HID DE N OA K S CT
DOGWOOD CT
THOMAS ST
C E N T R A L DR
K
Residential
Institutional
Colleyville Blvd Corridor
Open Space; Parks
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC24-010
5300 Colleyville Blvd
Future Land Use Map
LOT 1, BLOCK 1
GARDEN ADDITION
CAB. A, SLIDE 3587
P.R.T.C.T.
LOT 2, BLOCK 1
GARDEN ADDITION
CAB. A, SLIDE 3587
P.R.T.C.T.
LOT 1, BLOCK 1
H.E.C. ADDITION
VOL. 388-200, PG. 30
P.R.T.C.T.
LOT 1R-1, BLOCK 1
FIRST BAPTIST CHURCH OF COLLEYVILLE
DOC.# D214100097
O.P.R.T.C.T.
LOT 2, BLOCK 1
FIRST BAPTIST CHURCH OF COLLEYVILLE
DOC.# D214100097
O.P.R.T.C.T.S00°08'35"E 232.41'S00°16'32"E 144.17'S88°48'50"W
49.57'
S00°27'38"E
97.90'
S6
1
°
0
8
'
1
7
"
E
2
7
0
.
0
4
'S28°41'12"W 161.35'S28°57'40"W 316.62'S28°41'12"W 164.13'N6
6
°
5
2
'
2
3
"
W
2
7
3
.
0
9
'N15°44'10"E 118.91'N88°36'33"W 273.87'
N89°27'50"W
36.89'
N88°42'38"W 189.57'N00°36'43"W 548.72'N89°14'48"E
14.57'N00°52'11"W 389.28'N88°32'34"E 483.03'S01°02'58"E 147.00'N88°57'46"E
116.01'N01°03'14"W 146.65'N88°23'38"E 130.28'
L=109.00', R=258.00'
D=24°12'23"
S79°30'11"E~108.19'
N61°20'02"W
1.33'
S62°39'41"E
2.85'
REMAINDER
LOT 1, JOHN W.
WRIGHT SUBDIVISION
VOL. 388-131, PG. 26,
P.R.T.C.T.
FIRST BAPTIST CHURCH OF COLLEYVILLE
VOL. 5543, PG. 860, D.R.T.C.T.
FIRST BAPTIST CHURCH OF COLLEYVILLE
DOC.# D212294671, O.P.R.T.C.T.
HATCHED AREA INCLUDED IN "TRACT II" OF RESOLUTION
MEETING OF FIRST BAPTIST CHURCH OF COLLEYVILLE
VOL. 5543, PG. 857, D.R.T.C.T., BUT EXCLUDED FROM
DEED DOC.# D212294671. DEVELOPER HAS NOT
PROVIDED A VESTING DEED OR TITLE SEARCH DATA.
101.19'
LOT J, BLOCK 1, E.M.
THOMPSON SUBDIVISION
VOL. 388-K, PG. 197, P.R.T.C..T
DENNIS JOHN FEGAN, II
DOC.# D214167151
O.P.R.T.C.T
LOT I & PART OF LOT F, BLOCK 1,
E.M. THOMPSON SUBDIVISION
VOL. 388-K, PG. 197, P.R.T.C..T
KAY LYNN FOSTER HART
VOL. 11546, PG. 2304
D.R.T.C.T.
LOT B-R
E.M. THOMPSON SUBDIVISION
CAB. A, SLIDE 3399
P.R.T.C.T.
LOT 1, BLOCK 1
BAYLOR-EMERUS ADDITION
DOC.# D214055477
P.R.T.C.T.
LOT 1, BLOCK 1
LINTON ADDITION
DOC.# D208110450
P.R.T.C.T.
CHURCH STREET
(VARIABLE WIDTH R.O.W. AS SHOWN ON DOC.# D214100097, O.
P
.
R
.
T
.
C
.
T
.
)PLEASANT RUN ROAD(VARIABLE WIDTH R.O.W. AS SHOWN ON CAB. A, SLIDE 3587, P.R.T.C.T.)COLLEYVILLE BOULEVARD(STATE HIGHWAY 26)(VARIABLE WIDTH R.O.W. AS SHOWN ONDOC.# D214100097, O.P.R.T.C.T.)N89°48'38"E
86.50'
N61°0
8'
0
5
"
E
9
4.
0
6'
L=98.43', R=341.00'
D=016°32'19"
S45°06'39"E~98.09'S01°10'29"E 131.21'LOT 1R-1-A, BLOCK 1
20.085 ACRES | 874,916 SQ. FT.
LOT 1
BLOCK 1
RATLIFF ADDITION
VOL. 388-132
PG. 82
P.R.T.C.T.
D & V WALKER PROPERTIES, LLC
DOC.# D213034059
D.R.T.C.T.
LOT 1
BLOCK 1
GLORY HOUSE
COLLEYVILLE
ADDITION
DOC.# D217154151,
P.R.T.C.T.
LOT 1, BLOCK 1
FIRST UNITED METHODIST
CHURCH ADDITION
VOL. 388-180, PG. 36
P.R.T.C.T.
THE DIOCESE OF NEWTON FOR
THE MELKITES IN THE UNITED
STATES OF AMERICA, INC.
DOC.# D223190463
O.P.R.T.C.T.
CHURCH OF CHRIST AT
COLLEYVILLE
VOL. 3518, PG. 105
D.R.T.C.T.
LOT 1, BLOCK 1
N3 DEVELOPMENT ADDITION
CAB. A, SLIDE 12775
P.R.T.C.T.
LOT 1R, BLOCK 1
STARBUCKS ADDITION
CAB. A, SLIDE 11259
P.R.T.C.T.
LOT 2-R,
BLOCK 1
B.D. SMITH
ADDITION
VOL. 388-157,
PG. 18
P.R.T.C.T.
LOT 1, BLOCK 2
COLLEYVILLE
ESTATES
VOL. 388-16,
PG. 113
P.R.T.C.T.
THOMAS
STREET
(60' R.O.W. PER VOL. 388-17,
PG. 303, P.R.T.C.T.)
LOT 1, BLOCK 1
B.D. SMITH
ADDITION
VOL. 388-17,
PG. 303
P.R.T.C.T.
LOT 2
BLOCK 1
HARRELSON
ADDITION
VOL. 388-180,
PG. 35
P.R.T.C.T.
LOT 2, BLOCK 1
BROWN
ADDITION
CAB. A, SLIDE
7693
P.R.T.C.T.
LOT 1, BLOCK 1
COLLEYVILLE
HEIGHTS
CAB. A, SLIDE
11395
P.R.T.C.T.
LOT 16,
BLOCK 1
COLLEYVILLE
HEIGHTS
OPEN SPACE,
DRAINAGE &
UTILITY EASEMENT
CAB. A, SLIDE
11395
P.R.T.C.T.
REGINA COURT
(50' R.O.W. PER CAB. A, SLIDE
11395, P.R.T.C.T.)
LOT 1R, BLOCK 2
RATLIFF
ADDITION
DOC.#
D211195550
P.R.T.C.T.
LOT 1, BLOCK 1
CORLEY SUBDIVISION
VOL. 388-207, PG. 6
P.R.T.C.T.
LOT 1, BLOCK 1
GREEN ACRES
CAB. B, SLIDE 202
P.R.T.C.T.
LOT 1, BLOCK 1
TUTUN ADDITION
VOL. 388-179, PG. 50
P.R.T.C.T.
LOT 1, BLOCK 1
BOJKU FAMILY ADDITION
CAB. A, SLIDE 4675
P.R.T.C.T.
LOT 1, BLOCK 1
SKY BLUE PLACE
DOC.# D218067966
P.R.T.C.T.
LOT 4, BLOCK 1, NORTHEAST
PROFESSIONAL PARK
VOL. 388-184, PG. 36
P.R.T.C.T.
CENTRAL DRIVE
(50' R.O.W. PER VOL.
388-132, PG. 82, P.R.T.C.T.)
HIDDEN
OAKS DRIVE
(VARIABLE WIDTH
R.O.W. PER DOC.#
D206397059,
O.P.R.T.C.T.)
POINT OF
BEGINNING
VICINITY MAP - NOT TO SCALE
SITE
LEGEND OF ABBREVIATIONS
·D.R.T.C.T. DEED RECORDS, TARRANT COUNTY, TEXAS
·P.R.T.C.T.PLAT RECORDS, TARRANT COUNTY, TEXAS
·O.P.R.T.C.T.OFFICIAL PUBLIC RECORDS, TARRANT COUNTY, TEXAS
·DOC.#DOCUMENT NUMBER
·C.M.CONTROLLING MONUMENT
·SQ. FT.SQUARE FEET
·R.O.W.RIGHT OF WAY
·CRS CAPPED REBAR SET
SURVEYOR'S NOTES:
1.Bearings are based on the State Plane Coordinate System, Texas North Central
Zone (4202) North American Datum of 1983 (NAD '83), distances are surface with
a combined scale factor of 1.00012.
2.This property lies within Zone "X" and "X-Shaded" of the Flood Insurance Rate
Map for Tarrant County, Texas and Incorporated Areas, map no. 48439C0095K,
with an effective date of September 25, 2009, via scaled map location and graphic
plotting.
3.Monuments are found unless specifically designated as set.
4.The purpose of this plat is to combine 5 existing platted lots and two tracts of land
into a single lot for future development.
5.This plat was prepared without the benefit of a commitment for title insurance
covering all tracts shown hereon. The surveyor has not abstracted the property,
or performed an independent title search. Therefore, there may exist easements,
encumbrances, or other title matters, either recorded or unrecorded, which affect
the subject property and are not shown hereon.
THIS PLAT RECORDED ON (DATE) ______________, IN INSTRUMENT NO. __________________________.
5200 State Highway 121
Colleyville, TX 76034
Phone: 817-488-4960
DRAWN:BCS
CHECKED:JHB
TABLE OF REVISIONS
COLLEYVILLE,
TEXAS SHEET 1 OF 2
FIRST BAPTIST
CHURCH OF
COLLEYVILLE
JOB NO.2024.001.352
SCALE: 1" = 60'
60'0 30'60'120'
FINAL PLAT
LOT 1R-1-A, BLOCK 1
FIRST BAPTIST CHURCH OF COLLEYVILLE
BEING A REPLAT OF LOTS 1 & 2, BLOCK 1 OF GARDEN ADDITION; LOT
1, BLOCK 1 OF H.E.C. ADDITION; & LOTS 1R-1 & 2, BLOCK 1 OF FIRST
BAPTIST CHURCH OF COLLEYVILLE, TOGETHER WITH TWO TRACTS OF
LAND OUT OF THE J.M. LOONEY SURVEY, ABSTRACT #936
20.085 ACRES IN THE CITY COLLEYVILLE, TARRANT COUNTY, TEXAS
DECEMBER 2024
OWNER
FIRST BAPTIST CHURCH OF COLLEYVILLE
5405 PLEASANT RUN ROAD
COLLEVILLE, TX 76034
817.281.4158
ENGINEER
KIRKMAN ENGINEERING
5200 STATE HIGHWAY 121
COLLEVILLE, TX 76034
SYDNEY FOSTER
817.488.4960
SURVEYOR
JOHN H. BARTON III, RPLS #6737
BARTON CHAPA SURVEYING, LLC
3601 NE. LOOP 820
FORT WORTH, TX 76137
INFO@BCSDFW.COM
817.864.1957
STATE OF TEXAS §
COUNTY OF TARRANT §
WHEREAS FIRST BAPTIST CHURCH OF COLLEYVILLE is the owner of a tract situated in the J.M. Looney survey, abstract
number 936, City of Colleyville, Tarrant County, Texas, being the tracts described by deed to First Baptist Church of
Colleyville, recorded in volume 5543, page 860, Deed Records, Tarrant County, Texas, (D.R.T.C.T.) and document number
D212294671, Official Public Records, Tarrant County, Texas, (O.P.R.T.C.T.), together with the following lots:
·all of Lot 1 and part of Lot 2, Block 1, Garden Addition, an addition in the City of Colleyville, Tarrant County, Texas,
recorded in cabinet A, slide 3587, Plat Records, Tarrant County, Texas, (P.R.T.C.T.)
·all of Lot 1, Block 1, H.E.C. Addition, an addition in the City of Colleyville, Tarrant County, Texas, recorded in volume
388-200, page 30, (P.R.T.C.T.)
·all of Lot 1R-1 and Lot 2, Block 1, First Baptist Church of Colleyville, an addition in the City of Colleyville, Tarrant
County, Texas, recorded in document number D214100097, (P.R.T.C.T.)
the subject tract being more particularly described as follows:
BEGINNING at a 2 inch iron pipe found for the westernmost northwest corner of Lot 2 of said First Baptist Church of
Colleyville (D214100097), same being in the east line of Lot 2 of said Garden Addition;
THENCE with the perimeter and to the corners of Lot 2 of said First Baptist Church of Colleyville (D214100097), the
following calls:
1.North 88 degrees 57 minutes 46 seconds East, a distance of 116.01 feet to a 3/8 inch rebar found;
2.North 01 degrees 03 minutes 14 seconds West, a distance of 146.65 feet to a 1/2 inch rebar with cap stamped,
“SPRY” found;
3.North 88 degrees 23 minutes 38 seconds East, a distance of 130.28 feet to a 5/8 inch rebar with cap stamped, “BHB”
found at the beginning of a tangent curve to the right, having a radius of 258.00 feet, with a delta angle of 24
degrees 12 minutes 23 seconds, whose chord bears South 79 degrees 30 minutes 11 seconds East, a distance of
108.19 feet;
4.Along said tangent curve to the right, an arc length of 109.00 feet to a 5/8 inch rebar with an illegible cap found,
from which a 5/8 inch rebar with an illegible cap found bears North 53 degrees West, a distance of 0.78 feet;
5.South 00 degrees 08 minutes 35 seconds East, a distance of 232.41 feet to a 5/8 inch rebar with an illegible cap
found;
6.South 00 degrees 16 minutes 32 seconds East, a distance of 144.17 feet to a 1/2 inch rebar with cap stamped, “JPH”
found;
7.South 88 degrees 48 minutes 40 seconds West, a distance of 49.57 feet to a 5/8 inch rebar with cap stamped, “SAM”
found for a re-entrant corner of Lot 2 of said First Baptist Church of Colleyville (D214100097), same being the
northernmost northeast corner of Lot 1R-1 of said First Baptist Church of Colleyville (D214100097);
THENCE with the perimeter and to the corners of Lot 1R-1 of said First Baptist Church of Colleyville (D214100097), the
following calls:
1.South 00 degrees 27 minutes 38 seconds East, a distance of 97.90 feet to an “X” cut found;
2.South 61 degrees 08 minutes 17 seconds East, a distance of 270.04 feet to a 1/2 inch rebar with pink cap stamped,
“BARTON CHAPA” set (hereinafter called “capped rebar set”);
3.South 28 degrees 41 minutes 12 seconds West, a distance of 161.35 feet to an aluminum monument stamped
“TEXAS DEPARTMENT OF TRANSPORTATION” found;
4.South 62 degrees 39 minutes 41 seconds East, a distance of 2.85 feet to a point from which a disturbed aluminum
monument stamped “TEXAS DEPARTMENT OF TRANSPORTATION” found bears South 38 degrees East, a distance of
0.35 feet;
5.South 28 degrees 57 minutes 40 seconds West, a distance of 316.62 feet to point from which an aluminum
monument stamped “TEXAS DEPARTMENT OF TRANSPORTATION” found bears North 76 degrees East, a distance of
0.34 feet;
6.North 61 degrees 20 minutes 02 seconds West, a distance of 1.33 feet to a 5/8 inch rebar found;
7.South 28 degrees 41 minutes 12 seconds West, a distance of 164.13 feet to a point from which an aluminum
monument stamped “TEXAS DEPARTMENT OF TRANSPORTATION” found bears South 01 degrees East, a distance of
0.31 feet and from which a 1/2 inch rebar with cap stamped, “MOAK” found bears South 01 degrees East, a distance
of 1.09 feet;
8.North 66 degrees 52 minutes 23 seconds West, a distance of 273.09 feet to a 3/4 inch rebar found in concrete;
9.North 15 degrees 44 minutes 10 seconds East, a distance of 118.91 feet to a bent 1/2 inch rebar found in concrete;
10.North 88 degrees 36 minutes 33 seconds West, passing the southwest corner of Lot 1R-1 of said First Baptist
Church of Colleyville at a distance of 101.19 feet (from which a 1/2 inch rebar with an illegible cap found bears 0.30
feet south), continuing with the southernmost line of said First Baptist Church of Colleyville tract (5543/860), for a
total distance of 273.87 feet to a 3 inch metal fence corner post found for the southernmost southwest corner of
said First Baptist Church of Colleyville tract (5543/860), from which an “X” cut found on concrete post base bears
North 01 degrees West, 0.26 feet, also from which a 3/8 inch rebar found bears North 28 degrees East, 3.86 feet;
THENCE North 89 degrees 27 minutes 50 seconds West, a distance of 36.89 feet to a 1/2 inch rebar found for the
southeast corner of said First Baptist Church of Colleyville tract (D212294671), lying in the north line of Lot J, Block 1,
E.M. Thompson Subdivision, an addition in the City of Colleyville, Tarrant County, Texas, recorded in volume 388-K, page
197, (P.R.T.C.T.),;
THENCE North 88 degrees 42 minutes 38 seconds West, with the north line of said Lot J and the south line of said First
Baptist Church of Colleyville tract (D212294671), a distance of 189.57 feet to a capped rebar set for the southwest corner
of said First Baptist Church of Colleyville tract;
THENCE North 00 degrees 36 minutes 43 seconds West, with the west line of said First Baptist Church of Colleyville tract
(D212294671), passing the northwest corner thereof, same being the westernmost southwest corner of said First Baptist
Church of Colleyville tract (5543/860), continuing and passing the northwest corner thereof, same being the southwest
corner of Lot 1 of said H.E.C. Addition, and continuing for a total distance of 548.72 feet to a 1 inch rebar found for the
northwest corner of said H.E.C. Addition;
THENCE North 89 degrees 14 minutes 48 seconds East, with the north line of said H.E.C. Addition, a distance of 14.57
feet to an “X” set in concrete for the southwest corner of Lot 1 of said Garden Addition;
THENCE North 00 degrees 52 minutes 11 seconds West, with the west line of said Garden Addition, a distance of 389.28
feet to an “X” set in concrete for the southwest corner of the permanent right-of-way to the City of Colleyville, recorded
in document number D209039551 (O.P.R.T.C.T.);
THENCE North 88 degrees 32 minutes 34 seconds East, with the south line of said permanent right-of-way, a distance of
483.03 feet to its southeast corner, from which a 1/2 inch rebar with cap stamped “PREMIER” found on the west line of
Lot 1, John W, Wright Subdivision, an addition in the City of Colleyville, recorded in volume 388-131, page 26 (P.R.T.C.T.),
same being the southwest corner of a right-of-way dedication to the City of Colleyville recorded in document number
D207293690 (O.P.R.T.C.T) bears South 01 degree East, 1.68 feet;
THENCE South 01 degrees 02 minutes 58 seconds East, with the east line of Lot 2 of said Garden Addition and the west
line of said John W. Wright Subdivision, a distance of 147.00 feet, returning to the POINT OF BEGINNING and enclosing
20.085 acres (874,916 square feet) of land, more or less.
NOW THEREFORE, KNOW ALL PERSONS BY THESE PRESENTS:
That FIRST BAPTIST CHURCH OF COLLEYVILLE, does hereby adopt this plat designating the hereinbefore described
property as LOT 1R-1-A, BLOCK 1, FIRST BAPTIST CHURCH OF COLLEYVILLE, an addition to the City of Colleyville, Tarrant
County, Texas, and do hereby dedicate fee simple to the public use forever all streets, rights-of-way, and alleys shown
thereon, and do hereby reserve the easements shown on this plat for the mutual use and accommodation of all public
utilities desiring to use or using the same. Any public utility shall have the right to remove and keep removed all or part
of any buildings, fences, trees, shrubs or other improvements or growths in which any way endanger or interfere with
the construction , maintenance or efficiency of its respective systems on any of these easements, and any public utility
shall at all times have the right of ingress and egress to and from and upon the said easement for the purpose of
constructing, reconstructing, inspecting, and patrolling, without the necessity at any time of procuring the permission of
anyone. This plat approved subject to all platting ordinances, rules, regulations, and resolutions of the City of Colleyville,
Texas.
Witness my hand this _________________________ day of _________________, 20_____.
_________________________________________________
First Baptist Church of Colleyville (authorized agent)
STATE OF TEXAS §
COUNTY OF _________ §
BEFORE ME, the undersigned, a Notary Public in and for the State of Texas, on this day personally appeared
_______________________, known to me to be the person whose name is subscribed to the foregoing instrument and
acknowledged to me that he/she executed the same as for the purpose and consideration therein expressed, and in the
capacity therein stated.
_____________________
Notary Public in and for
the State of Texas
SURVEYOR'S CERTIFICATE
This is to certify that I, John H. Barton III, a Registered Professional Land Surveyor of the State of Texas, do hereby certify
that this Plat is true and correct and was prepared from an actual survey made under my supervision on the ground.
Further, this survey conforms to the general rules of procedures and practices of the most current Professional Land
Surveying Practices Act. Fieldwork was completed on 11/25/2024.
______________________________________________________
John H. Barton III, RPLS# 6737 Date
Planning and Zoning Commission Approval
WHEREAS The Planning and Zoning Commission of the
City of Colleyville, Texas voted affirmatively on
this______________________________ day of
_____________________________, 20_______, to
approve this Plat.
___________________________________________
Chairman, Planning and Zoning Commission
____________________________________________
Attest: Secretary, Planning and Zoning Commission
City Council Approval
WHEREAS The City Council of the City of Colleyville,
Texas voted affirmatively on this__________ day of
_____________________________, 20_______, to
approve this Plat.
___________________________________________
Mayor, City of Colleyville
____________________________________________
Attest: City Secretary
FINAL PLAT
LOT 1R-1-A, BLOCK 1
FIRST BAPTIST CHURCH OF COLLEYVILLE
BEING A REPLAT OF LOTS 1 & 2, BLOCK 1 OF GARDEN ADDITION; LOT
1, BLOCK 1 OF H.E.C. ADDITION; & LOTS 1R-1 & 2, BLOCK 1 OF FIRST
BAPTIST CHURCH OF COLLEYVILLE, TOGETHER WITH TWO TRACTS OF
LAND OUT OF THE J.M. LOONEY SURVEY, ABSTRACT #936
20.085 ACRES IN THE CITY COLLEYVILLE, TARRANT COUNTY, TEXAS
DECEMBER 2024
THIS PLAT RECORDED ON (DATE) ______________, IN INSTRUMENT NO. __________________________.
SHEET 2 OF 2
DRAWN:BCS
CHECKED:JHB
TABLE OF REVISIONS
JOB NO.2024.001.352
OWNER
FIRST BAPTIST CHURCH OF COLLEYVILLE
5405 PLEASANT RUN ROAD
COLLEVILLE, TX 76034
817.281.4158
ENGINEER
KIRKMAN ENGINEERING
5200 STATE HIGHWAY 121
COLLEVILLE, TX 76034
SYDNEY FOSTER
817.488.4960
SURVEYOR
JOHN H. BARTON III, RPLS #6737
BARTON CHAPA SURVEYING, LLC
3601 NE. LOOP 820
FORT WORTH, TX 76137
INFO@BCSDFW.COM
817.864.1957 5200 State Highway 121
Colleyville, TX 76034
Phone: 817-488-4960
COLLEYVILLE,
TEXAS
FIRST BAPTIST
CHURCH OF
COLLEYVILLE
PRELIMINARY
THIS DOCUMENT SHALL NOT BE RECORDED FOR ANY PURPOSE AND
SHALL NOT BE USED, VIEWED, OR RELIED UPON AS A FINAL SURVEY
DOCUMENT. RELEASED FOR INTERIM REVIEW December 10, 2024
5232
5300
1007
1000
5200
5405
5505
5300
5401
700 704
800
705701
803 805
5405
1003
1000
908
909 1001 1005 5606
910
908
909 1001
5801
5709
5707
5705
5703
5701
5609
5605
5603
5601
5709
5707
5705
5703
5611
5609
5607
5500
811
5700
5702
5704 5705
809
5703
5701
807805803
801
5700
5702
1109
5520
5105
5108
5309
5301
1105
1104
5112 5113
713 717
5712617
5310817
815811713
711
816814712
1200
1300
5307
5508
5504
5412
5510
5301
5309
5121
5201
5615
5605
5501
5601
5609
5505
5509
5695
1205
1221
1201
5199
5600
57081213
1211
5311
90
77
100
84
5217
5201
520416
5209
5201
5201
704 708 800 804 808 812
5513
5509
805801709705
5412
701
704700
701 705
704
701 705
704700
825
828
5150
5109
5226
5312
5313
5109
5104
1008
H
A
L
LJOHNSON RD
PLEASANT RUN RDMAIN ST COLLEYVILLE BLVDCH
U
R
C
H
S
T
COTTAGE LNVILLAGELNC A S A LN
PIAZZA LNSOUTHDR RIVERWALKDRLAUREL OAKS LN
COLLEYVILLE TERR
FIELD ST
HILLSIDE RD
NUECES CT
V E R A N D A LN
MISSIONLNREGINA CT
HID DE N OA K S CT
DOGWOOD CT
THOMAS ST
C E N T R A L DR
K
Parcels to be notified
Buffer
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC24-010
5300 Colleyville Blvd
Notification Map
NOTICE OF PUBLIC HEARING
«Owner_Name»
«Owner_Address»
«Owner_City» «Owner_Zip»
The City of Colleyville has scheduled public hearings concerning the below referenced request on the
following dates and location:
Planning and Zoning Commission Meeting: Monday, February 10, 2025 at 7:00 p.m.
City Council Meeting: Tuesday, March 4, 2025
3rd floor of City Hall, 100 Main Street, Colleyville, Texas
Request: Consideration of a Replat for Lot 1R-1-A, Block 1, First Baptist Church
of Colleyville Addition, being Lots 1 & 2, Block 1, Garden Addition; Lot
1, Block 1, H.E.C. Addition; Lots 1R-1 & 2, Block 1, First Baptist Church
of Colleyville Addition; & Tracts 1C & Tract 1C03, Abstract 936, Joseph
M. Looney Survey, located at 5300 Colleyville Boulevard, 1007 Church
Street, & 5312, 5313, 5405, & 5505 Pleasant Run Road. The request is to
allow for the Cross Creek Church Campus to be platted together as one
lot.
Zoning Case: PC25-002 Applicant: Zach Towery
Owner: First Baptist Church Colleyville Location: 5300 Colleyville B, 1007 Church Street, & 5312, 5313, 5405, & 5505 Pleasant Run Road.
Property Description:Lots 1 & 2, Block 1, Garden Addition; Lot 1, Block 1, H.E.C. Addition;
Lots 1R-1-1 & 2, Block 1, First Baptist Church of Colleyville Addition; & Tracts 1C & Tract 1C03, Abstract 936, Joseph M. Looney Survey Present Zoning: CC-1, Village Retail
This notice has been sent to all owners of real property within 500 feet of the request as such ownership appears on the last approved tax roll and all homeowners associations within 1000 feet. Approval by the Planning and Zoning Commission serves as a recommendation to the City Council and is not a final action on the request. Denial of the proposal by the Commission is final, unless the applicant submits a written notice of appeal within 10 days from the date of action by the Commission. If appealed, the request will
be placed on the next available City Council agenda as listed above. Rezoning requests, zoning
amendments and conditions recommended by the Commission for approval by the City Council may be more restrictive than those described in this notice.
All interested persons are encouraged to attend the public hearing and express their opinions on the zoning
change request. If you are unable to attend, but wish to have your opinions made a part of the public record,
please submit written comments prior to the public hearing, to the address or email below:
Community Development Department
City of Colleyville
100 Main Street
Colleyville, TX 76034
Citizenletters@Colleyville.com
The application is on file for public examination in the Community Development Department at 100 Main
Street, Colleyville, Texas 76034. A brief project description can be found online on the Agenda Packet and
Active Development Case map (please use your phone’s camera to scan QR code below):
For additional information, please contact the Community Development Department at 817.503.1050.
Please reference the case number when requesting information.
Kristopher Potts
Planner
1
Notification List
Owner_Name Situs_Addr
COLLEYVILLE LOFTS VENTURE LLC 5232 COLLEYVILLE BLVD
FIRST UNITED METH COLLEYVILLE 1000 CHURCH ST
REDEEMED CHRISTIAN CHURCH OF GOD GLORY HOUSE 5300 PLEASANT RUN RD
BRADY, BLAKE 5401 COLLEYVILLE BLVD
GRACIA, MACEDONIO 803 THOMAS ST
ROEMING, BRANTON F 805 THOMAS ST
CORE-FULMER, SARAH ELIZABETH 5604 HIDDEN OAKS DR
LYKINS, DEBBIE S 5609 PLEASANT RUN RD
LEACH, TERRY 5605 HIDDEN OAKS DR
CORGAN, KYLE D 5603 HIDDEN OAKS DR
CHIVAKULA, LAKSHMI 5601 HIDDEN OAKS DR
GII SHP EBSW DFW LLC 5500 COLLEYVILLE BLVD
JD JUDD REALTY HOLDINGS LLC 1109 CHURCH ST
2727 PN SPE LLC 5520 COLLEYVILLE BLVD
BAJRAM & RUZDI INVESTMENTS LLC 5309 COLLEYVILLE BLVD
BARNARD PARTNERS XVIII LTD 1104 PROFESSIONAL CT
KIPTON ANDERSON INVESTMENTS LL 5303 COLLEYVILLE BLVD
BETHEL METHODIST CHURCH OF NORTH TEXAS 5310 PLEASANT RUN RD
FIGUEROA FAMILY REVOCABLE TRUST 817 CENTRAL DR
GROFFMAN, STEVEN 815 CENTRAL DR
DS & RS PROPERTIES LLC 5320 Pleasant Run RD
EARTH TO MOON REALTY LLC 820 CENTRAL DR
LALA FAMILY TRUST 816 CENTRAL DR
MCDONALD, CEACY SAMANTHA 814 CENTRAL DR
C & S SKY BLUE CORPORATION 5307 COLLEYVILLE BLVD
HOFFMAN, ROBERT 5504 PLEASANT RUN RD
MOFFETT, JESSE 806 THOMAS ST
SHRESTHA, NEENA 804 THOMAS ST
FAZAL, JASIM 802 THOMAS ST
MITCHELL, JEWELL O 800 THOMAS ST
CRANDALL, BRUCE 5412 PLEASANT RUN RD
DEDIEGO FAMILY TRUST 5510 COLLEYVILLE BLVD
HART, KAY LYNN FOSTER 5301 PLEASANT RUN RD
FEGAN, DENNIS JOHN 5309 PLEASANT RUN RD
CAVALIER INVESTMENT COMPANY INC 5501 COLLEYVILLE BLVD
MDC COAST 7 LLC 1221 CHURCH ST
BRANCH BANKING & TRUST CO 1201 CHURCH ST
EAGLE-COLLEYVILLE TOWNE SQUARE 5600 COLLEYVILLE BLVD
SHEMAKER, SIMON 32 VERANDA LN
SHEWMAKER, SIMON 32 VERANDA LN
JOHN MCNEEL & SYLVIE MCNEEL REVOCABLE LIVING TR34 VERANDA LN
SPICER, TAMARA 5201 PLEASANT RUN RD
DDK REAL ESTATE INV LLC 5204 COLLEYVILLE BLVD
VILLAGE OWNERS ASSOCIATION INC 16 MAIN ST
LAHODA, BARTON G 1009 CHURCH ST
HENDRICKSON, JACK H 808 COLLEYVILLE TERR
CASLER, LINDA 812 COLLEYVILLE TERR
JENNINGS, ALLISON 805 COLLEYVILLE TERR
MILLER, JEFFREY D 801 COLLEYVILLE TERR
SHIMONEK, NICOLAS 801 THOMAS ST
FLORY, BRETT 5412 SOUTH DR
ALAN AND CINDY MITZEL REVOCABLE TRUST 800 REGINA CT
CARDINI, CHRISTOPHER 821 REGINA CT
CHACKO, RAIBU 817 REGINA CT
KIM & DEBORAH SHELTON TRUST 813 REGINA CT
TUMPAK, SCOTT 809 REGINA CT
LONG, MATTHEW 805 REGINA CT
2
Notification List
COLLEYVILLE HEIGHTS LLC 801 REGINA CT
GREENBERG, MICHELLE 804 REGINA CT
TERESA SCHEMMEL INGRAM REVOCABLE TRUST 808 REGINA CT
BARNES, MICHAEL 812 REGINA CT
BELL, MICHAEL W 816 REGINA CT
WANDER, CHRIS 820 REGINA CT
R P GANTOS VENTURES LLC 5413 COLLEYVILLE BLVD
D & V WALKER PROPERTIES LLC 5226 PLEASANT RUN RD
FIRST BAPTIST CH COLLEYVILLE 5313 PLEASANT RUN RD
DIOCESE OF NEWTON FOR THE MELKITES IN THE UNITE 1008 CHURCH ST
COLLEYVILLE CHURCH OF CHRIST 1008 CHURCH ST
RIVERWALK AT COLLEYVILLE COURTESY NOTICE
LAUREL OAKS ESTATES COURTESY NOTICE
COLLEYVILLE HEIGHTS COURTESY NOTICE
GRAPEVINE COLLEYVILLE ISD STATE REQUIRED
Towery, Zach 5300 Colleyville Blvd
RESOLUTION R-25-
A RESOLUTION APPROVING A REPLAT FOR LOT WITH FOR LOT 1R-1-
A, BLOCK 1, FIRST BAPTIST CHURCH OF COLLEYVILLE ADDITION
WHEREAS, the Planning and Zoning Commission recommended approval of
the Replat for Lot 1R-1-A, Block 1, First Baptist Church of
Colleyville Addition on February 10, 2025.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE
CITY OF COLLEYVILLE, TEXAS:
Sec. 1. THAT the Replat for Lot 1R-1-A, Block 1, First Baptist Church of
Colleyville Addition, being approximately 20.09 acres, attached
as Exhibit “A" - Plat Exhibit, is hereby approved.
AND IT IS SO RESOLVED.
APPROVED BY A VOTE OF ___ AYES, ___ NAYS, AND ___ ABSTENTIONS ON THIS
THE 4TH DAY OF MARCH 2025.
Mayor Bobby Lindamood Mayor Pro Tem Brandi Elder
Place 2, Mark Alphonso Place 5, Kimberly Holt Gunderson
Place 3, Scotty Richardson Place 6, Tim Raine
Place 4, Ben Graves
ATTEST: CITY OF COLLEYVILLE
Christine Loven, TRMC Bobby Lindamood
Assistant City Secretary Mayor
Exhibit “A” - Plat Exhibit
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
BRIEFING
Agenda Number 2c Agenda Date 2/10/2025 Number -
Type Public Hearing Agenda Items
Department Community Development
Title
Consideration of a rezoning from AG Agricultural to R-30 Single Family Residential and
R-40 Single Family Residential districts on Tracts 4A2 and 4B2, 4A3 and 4B3, Abstract
295, William E. Crooks Survey, being located at 7316 and 116 John McCain Road, Case
ZC25-001
Explanation
Curtis Young, the applicant, has submitted a request for a Rezoning from AG Agricultural
to R-40 and R-30 Single Family Residential on Tracts 4A2 and 4B2, 4A3 and 4B3, and
4E, Abstract 295, William E. Crooks Survey, being approximately 11.81 acres, and
zoned AG Agricultural. The purpose of the rezoning is to allow for the development of a
12 home subdivision.
Existing Conditions/Background: The subject property, 7316 and 116 John McCain
Rd, is zoned AG Agricultural. It is located southeast of the intersection of Bandit Trail
and John McCain Road. There are currently two homes that sit on the respective
properties that are intended to be removed.
Proposed Zoning Change: The request is to rezone from the AG Agricultural district to
the R-40 and R-30 Single Family Residential District.
Analysis: Per the proposed, the applicant is requesting to rezone the property to allow
for a new 12 lot subdivision with 7 of the lots being R-30 Single Family Residential and 5
of the lots being R-40 Single Family Residential. The development will derive its access
from one cul-de-sac off of John McCain Road. The applicant is proposing to improve and
utilize an existing private access easement to the south, which would provide a second
point of access for emergency services. The proposed development will require a waiver
from the provisions of Section 9.17 of the Land Development Code, Street Design
Criteria if the emergency access easement is not desired. The maximum number of lots
served on a single cul-de-sac with R-40 or R-30 zoning per Section 9.17 is 10 lots,
whereas this is proposing 12 lots.
Plat Status: The subject property is unplatted as Tracts 4A2 and 4B2, 4A3 and 4B3,
and 4E, Abstract 295, William E. Crooks Survey.
DRC Review: The DRC reviewed the request during their January 21, 2025 meeting and
provided the following comments.
City of Colleyville Page 2
Planning and Zoning
Commission
Agenda Briefing 2c
1. Informational Comment – Due to the concept showing 12 lots, and not 10 in a cul-
de-sac, this configuration is required to obtain a waiver from City Council.
2. See attached pdf for Engineering Comments in red font.
Drainage: A drainage analysis will be required at the time of a Preliminary/Final plat.
Surrounding Development: The property to the east is zoned PUD-R and improved
with single-family homes in the Monticello neighborhood. The properties to the west are
zoned R-40 and R-20 Single Family Residential and improved with single-family homes.
The properties to the north are zoned R-30 and R-20 Single Family Residential and
improved with single-family homes. The property to the south is zoned R-40 Single
Family Residential and improved with a single family home.
Comprehensive Plan: The City’s Comprehensive Plan, Destination Colleyville, identifies
the subject property for residential development. The proposed request complies with
the future land use designation.
Tree Preservation: The development must comply with Chapter 5 (Urban Forestry) of
the Land Development Code. Where any tree is slated for removal, no site grading, dirt
disturbance or new construction may occur on the property until a Tree Removal Permit
has been issued that is associated with an approved Tree Preservation Plan.
In addition to the requirements for submittal of a Tree Removal Permit and Tree
Preservation Plan, future development on the site must maintain the minimum existing
protected tree canopy coverage as required in Chapter 5.
Public Notification: Staff mailed notices to all property owners within 500 feet as well
as any Homeowners Associations within 1000 feet of the subject property regarding this
request. Grapevine-Colleyville ISD, where the subject property is located, was notified
per State law. Notice was published in the Fort Worth Star-Telegram as required by
State law and the Land Development Code.
Staff Recommendation: Staff is neutral on this request.
Recommendation
None
Attachments
1. Aerial Map
2. Zoning Map
3. Future Land Use Map
4. Statement of Planning Objectives
5. Zoning Exhibit
City of Colleyville Page 3
Planning and Zoning
Commission
Agenda Briefing 2c
6. Drainage and Grading Plans
7. Utility Plan
8. Tree Survey Exhibit
9. Response to DRC Comments
10. Land Development Code Section 9.17 - Street Design Criteria
11. Notification Map
12. Notification Letter
13. Notification List
14. Opposition Map
15. Opposition Report
16. Draft Ordinance
MONTICELLOPKWYWESTMONTDRTILLMAN HILL RDJEFFERSONCIRC H A R L O T T E S V I L L E A V E
BANDIT TR
C H A R L O T T E S V I L L E AVE W
MADIS
O
N S
Q
JOHNMCCAI
NRDS T I L L W A T E R CIRCHANELCT ADAMS C T
HARDY LN
K
Subject Property
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC25-001
7316 John McCain Road
Aerial Map
MONTICELLOPKWYWESTMONTDRTILLMAN HILL RDJEFFERSONCIRC H A R L O T T E S V I L L E A V E
BANDIT TR
C H A R L O T T E S V I L L E AVE W
MADIS
O
N S
Q
JOHNMCCAI
NRDSTILLWATER CIRCHANELCT ADAMS C T
HARDY LN
AG
R-30
R-20
RE
AG
AG
PUD-R
AG
AG
PUD-R
PUD-R
R-40
R-20
PUD-R R-40
AG
AG
AG
R-40
R-40
R-20
R-20 R-20
R-20
AG
K
Subject Property
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC25-001
7316 John McCain Road
Zoning Map
MONTICELLOPKWYWESTMONTDRTILLMAN HILL RDJEFFERSONCIRC H A R L O T T E S V I L L E A V E
BANDIT TR
C H A R L O T T E S V I L L E AVE W
MADIS
O
N S
Q
JOHNMCCAI
NRDS T I L L W A T E R CIRCHANELCT ADAMS C T
HARDY LN
K
Residential
Open Space; Parks
Subject Property
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC25-001
7316 John McCain Road
Future Land Use Map
Holt Farms
Colleyville, Texas Zoning Narrative –10 January 2025
Calais Custom Homes- Owner/Developer Sage Group, Inc., Land Planner
Statement of Planning Objectives
Holt Farms is a proposed residential neighborhood of twelve ¾ acre and acre lots, to be
developed in the City of Colleyville. The approximately 11.7 acre property is located on
the east side of John McCain Road, near the intersection with Bandit Trail.
Adjacencies: The property is adjacent to,
On the north: Residential lots zoned R-30, and the Monticello Neighborhood-
zoned PUD-R with lots of 15,000+ sf.
On the west: the Monticello Neighborhood.
On the south: Residential lots zoned R-40 & RE.
On the west, across John McCain Road: Multiple lots zoned AG, R-20 & R-40.
The property has never been zoned for development and is still designated AG. This
proposal is a reflection of the above adjacencies, with proposed R-30 lots (1-7) adjacent to
the R-30 and smaller lots to the north and west, and proposed R-40 lots (8-12) adjacent to
the mostly R-40 zoning to the south. The total number of lots is 12, on almost 12 acres, for
a density of 1.02 lots/ acre. There is currently one occupied and another unoccupied
single-family home on the property, which will both be replaced with new structures.
Another home was recently removed, in anticipation of development.
We believe the proposed plan and resulting homes will at least equal and exceed most of
the lot sizes, and the quality and values of the neighborhoods and properties we are
adjacent to.
Quality and compatibility with the adjacent residential, in this portion of Colleyville is
essential, and we have designed this proposal with those goals in mind.
Access: The property currently only has one point of street access, from John McCain
Road, from which a cul-de-sac will be built, accessing the lots. We are also planning to
improve and utilize an existing private access easement to the south, which will provide a
second point of access for emergency services, and will not be open for daily use.
The residences planned for Holt Farms will be upscale, with selling prices estimated to
start at around $2.5 million plus. Holt Farms will be developed with the normal Colleyville
public street section of 31’ (back of curb to back of curb), in a 50’ R.O.W
There is an existing drainage and a small amount of flood plain affecting the southeast
corner of the property, and the fully developed storm drainage has been carefully
analyzed, and will be designed to meet all city regulations and not adversely affect any
neighboring properties. The property generally drains to the east, into this drainage.
To encourage pedestrian activity in the neighborhood, sidewalks will be built along the
front of each lot. The scale and orientation of the development has been designed to have
an inviting visual flow with the existing neighborhoods and surrounding uses, and the
location of the streets has been specifically adjusted to allow for the preservation of many
of the large Post Oak and Live Oak trees on the property. The design criteria of the homes
will create high quality designed homes in keeping with both the immediate
neighborhood and Colleyville as a whole.
Development Schedule
Holt Farms will be developed in one phase, with development commencing upon the
successful completion of the zoning and platting and the subsequent approval of the final
plat and engineering plans. Construction of homes is anticipated to start immediately
upon completion of the subdivision’s infrastructure.
1
30,025 S.F.
2
4
5
6
8
9
101112
40' FRONT SETBACK 40' FRONT SETBACK
25' REAR SETBACK 25' REAR SETBACK15' SIDE SETBACK40' FRONT SETBACK15' SIDE SETBACK25' REAR SETBACK40' FRONT SETBACK3
7
35' FRONT SETBACK 35' FRONT SETBACK
35' FRONT SETBACK10' SIDE SETBACK10' SIDE SETBACK10'
S
I
D
E
S
E
T
B
A
C
K
15'
S
I
D
E
S
E
T
B
A
C
K
25' REAR SETBACK 25' REAR SETBACK
25' REAR SETBACK
25' REAR SETBACK
25' REAR SETBACK10' SIDE SETBACK10' SIDE SETBACK154.1694.0886.54
116.
6
150.0030.0050.
0
0
30.
0
0
R50.
0
0
R40
.
0
0
R50.00
R40.00Emergency Access Easement30,013 S.F.30,007 S.F.
34,109 S.F.
37,621 S.F.
30,293 S.F.
30,207 S.F.
61,667 S.F.
40,543 S.F.
40,019 S.F.40,047 S.F.40,017 S.F.
Colleyville, Tarrant County, Texas
10 JAN 25
0 50'100'150'
1" = 50'
Concept Plan Holt Farms
Site Data
Gross Acreage
Gross Density
87.18 %
11.79 %
1.03 %
100.00%
Site Data Summary Chart
Single Family Residential Lots
Residential Lots
R.O.W.
R.O.W. Dedication
Gross Acreage
12
30,007 s.f.
37,047 s.f.
12
10.20 ac.
1.38 ac.
0.12 ac.
11.70 ac.
Zoning & Current Use
Existing Zoning:
Proposed Zoning:
Current Use:
Proposed Use:
AG
R -30 & R - 40
Residential
Single-family Residential
11.70 ac.
1.02/units
per ac.Lot Summary
Residential Lots
Minimum Lot Size
Average Lot Size
Planner:SAGE GROUP, INC.
Master Planning
Urban Design
Architecture
Landscape Architecture
1130 N. Carroll Ave., Ste. 200
Southlake, Texas 76092
817-424-2626
TBM MAG NAILN:7017269.1E:2377884.9ELEV:616.8'P R E L I M I N A R Y
FOR REVIEW ONLY
Not for Construction or Permit Purposes
P.E. No.
Engineer
Date
CLAYTON T. REDINGER
97497 2/04/2025
PREPARED FOR:CALAIS CUSTOM HOMES
1206 N CARROLL AVE
SOUTHLAKE, TEXAS 76092
(817) 481-6426
REDINGER GROUP, LLC
P.O. BOX 93206
SOUTHLAKE, TEXAS 76092
PHONE: (817) 253-5727
ENGINEERING FIRM REGISTRATION NUMBER F-23328
NORTH
EXISTING DRAINAGE PLAN
HOLT FARMS
COLLEYVILLE, TEXAS
NORTH
P R E L I M I N A R Y
FOR REVIEW ONLY
Not for Construction or Permit Purposes
P.E. No.
Engineer
Date
CLAYTON T. REDINGER
97497 2/04/2025
PREPARED FOR:CALAIS CUSTOM HOMES
1206 N CARROLL AVE
SOUTHLAKE, TEXAS 76092
(817) 481-6426
REDINGER GROUP, LLC
P.O. BOX 93206
SOUTHLAKE, TEXAS 76092
PHONE: (817) 253-5727
ENGINEERING FIRM REGISTRATION NUMBER F-23328
PRELIMINARY GRADING & DRAINAGE PLAN
HOLT FARMS
COLLEYVILLE, TEXAS
NORTH
P R E L I M I N A R Y
FOR REVIEW ONLY
Not for Construction or Permit Purposes
P.E. No.
Engineer
Date
CLAYTON T. REDINGER
97497 2/04/2025
PREPARED FOR:CALAIS CUSTOM HOMES
1206 N CARROLL AVE
SOUTHLAKE, TEXAS 76092
(817) 481-6426
REDINGER GROUP, LLC
P.O. BOX 93206
SOUTHLAKE, TEXAS 76092
PHONE: (817) 253-5727
ENGINEERING FIRM REGISTRATION NUMBER F-23328
NORTH
PRELIMINARY UTILITY PLAN
HOLT FARMS
COLLEYVILLE, TEXAS
6401
6402
6403
6404
6405
6406
6407
6408
6409
6410
6412
6413
6414
6415
6416
6417
6418
6419
6420
6421
6422
6423
6424 6425
6426
6427
6428
6429
6901
6902
6903
6904
6905
6906
6907
6908
6909
69106911
6912
6913
6914
6915
6916
6917
6918
6919
6920
6921
6922 6923
6924
6925
6926
6927
6928
6929
6930
6931
6932
6933
6934
6935
6936
6937
69386939
6940
6941
6942
6943
6944
6945
6946
6947
6948
6411
Trees
Protected Trees
Borderline Trees
Trees to be Altered
Total
Trees
53
14
6
73
Less
R.O.W.
-
-
5
5
Trees Net
of R.O.W.
53
14
1
68
Trees
%
77.94
20.59
1.47
100.00
PROTECTED TREES
Tree #
6405
6406
6407
6408
6409
6410
6411
6412
6413
6414
6415
Size & Species
24" OAK
16" PECAN
28" MULBERRY
28" MULBERRY
50" MULBERRY
10" ELM
60" ELM
30" MESQUITE
26" ELM
22" ELM
10" HACKBERRY
6416
6417
6418
6419
6420
6421
6422
6423
6424
6425
6426
6427
6428
6429
6901
10" OAK
24" WALNUT
12" CREPE MYRTLE
40" WALNUT
22" MULBERRY
16" OAK
28" BALD CYPRESS
28" OAK
24" MESQUITE
24" CEDAR ELM
36" ELM
20" ELM
14" ELM
36" OAK
26" OAK
6902
6903
6904
6905
6906
6907
6908
6909
6910
6911
6912
6913
6914
6915
6916
24" OAK
30" OAK
42" OAK
38" OAK
36" OAK
36" ELM
14" WILLOW
16" CEDAR
18" HACK
14" BRADFORD PEAR
14" CEDAR
6" ASH
10" CEDAR
9" CEDAR
20" LIVE OAK
6917
6918
6919
6920
6921
6922
6923
6924
6925
6926
6927
6928
6929
6930
6931
26" LIVE OAK
38" ELM
10" BRADFORD PEAR
14" OAK
14" OAK
18" PINE
20" PINE
30" LIVE OAK
36" OAK
42" OAK
20" OAK
6" BRADFORD PEAR
8" LIVE OAK
16" PINE
16" PINE
6932
6933
6934
6935
6936
6937
6938
6939
6940
6941
6942
6943
6944
6945
6946
18" PINE
18" PINE
16" PINE
14" PINE
16" PINE
20" PINE
20" PINE
24" PINE
20" PINE
16" PINE
14" PINE
28" OAK
32" OAK
18" LIVE OAK
20" LIVE OAK
6947
6948
36" LIVE OAK
8" BRADFORD PEAR
BORDERLINE TREES
Tree #Size & Species
TREES TO BE ALTERED
Tree #Size & Species
PROTECTED TREES
Tree #Size & Species
Colleyville, Tarrant County, Texas
10 JAN 25
0 50'100'150'
1" = 50'
Development Tree Conservation Plan Holt Farms
Planner:SAGE GROUP, INC.
Master Planning
Urban Design
Architecture
Landscape Architecture
1130 N. Carroll Ave., Ste. 200
Southlake, Texas 76092
817-424-2626
509,754 s.f.
≈113,227 s.f. -->22.21%
≈97,424 s.f. --> 86.04%
≈ 8,774 s.f. --> 7.75%
≈ 7,029 s.f. --> 6.21%
≈113,227 s.f. -->100.00%
Tree Canopy Coverage
Total site area
Total existing canopy
Preserved tree canopy
Protected tree canopy (green)
Borderline Trees (yellow)
Trees to be altered (red)
P.O. Box 93206 - Southlake, Tx 76092 - Phone: (817) 253-5727
January 24, 2025
TO: City of Colleyville
RE: ZC25-001 Holt Farms Zoning – 1st Review Response Letter
This letter is in response to comments received January 21, 2025 for the 1st review of the Zoning
Case for Holt Farms by our office. We offer the following responses to your comments:
ENGINEERING REVIEW
Existing Drainage Plan
1) Study showing pre and post developed conditions to support this statement required.
RESPONSE: To be provided under separate report.
Preliminary Grading & Drainage Plan
1) Optional storm drain along rear of southwestern lots.
RESPONSE: In discussions with the neighbor in question, he has requested
that his pond continue to receive runoff from Holt Farms. He has also requested
that we keep the runoff on our property (carrying it east) past a point where he
intends to construct a new pool. We believe the proposed plan to divert the
surface drainage with a berm to a point before allowing it to continue to run
onto the neighbor’s property is the best solution to the neighbor’s wishes.
2) Adjacent property has landscape bed here; point discharge will create issues.
RESPONSE: We will have to work closely with the neighbor to coordinate a
detailed solution, however we believe the intent shown on the plans is the most
desirable solution for both the developer and adjacent neighbor.
3) Verify where pond spillway goes and confirm development doesn’t impede flow.
RESPONSE: The pond discharges due south and I believe then runs along Holt
Farms’ west property line in a small swale to the south and does not enter the
development boundary.
4) Add drop inlet.
RESPONSE: Drop inlet added to lot 4.
5) Add storm drainage line & inlets along rear of easternmost lots.
RESPONSE: The elevation of the cul-de-sac will be pushed down to allow the
entirety of lot 5 to drain to the propose ROW. Lots 6, 7 and 8 all have access to
drain to the adjacent open space lot/drainage easement of Monticello. This
reflects the existing drainage pattern.
Preliminary Utility Plan
1) Move SS line to centerline of street.
RESPONSE: SS line moved to center of street.
2) Any way to eliminate two dead end waterlines?
City of Colleyville
January 24, 2025
Page 2
RESPONSE: After discussion with staff, the drawing has been adjusted
accordingly.
Please feel free to call us at 817-253-5727 to discuss any questions you may have.
Sincerely,
Clayton Redinger, P.E.
Redinger Group, LLC
817-253-5727
Colleyville, Texas, Land Development Code
Chapter 9 – Subdivision Design & Public Facilities Page 9 -7
the development until appropriate provisions have been made. These provisions shall include any
drainage design or construction plans necessary to accommodate the off-site drainage problem.
Section 9.16 Street Improvement Requirements
A. General Requirement – The developer shall construct, at his expense, street facilities necessary for the
proper development of the subdivision. The street system shall provide access to every lot in the
subdivision and be designed and constructed in accordance with the criteria contained in this Land
Development Code.
B. Improvements to Existing Unimproved Streets and Utilities – This section is applicable to a proposed
development situated adjacent to an existing street or municipal utility, which does not meet the standards
contained in the Land Development Code.(O-06-1562 / 02-07-06)
1.Improvements Required – If a proposed subdivision is situated adjacent to an existing street or
municipal utility, which does not meet the standards contained in this Land Development Code, the
developer shall bear the cost for constructing the infrastructure improvements required by this Land
Development Code in accordance with the General Infrastructure Policy contained elsewhere in the
Land Development Code.
For the purpose of this regulation, the calculation used for estimating the reconstruction costs for an
unimproved street shall include all street paving, curb and gutter, sidewalks, hike and bike trails, water
and sewer utilities, and drainage improvements. The improvements shall be sized in accordance with
the most recently approved Master Thoroughfare Plan or Capital Improvements Plan, which is
applicable.
2. Escrow – The Administrative Official may recommend approval of a subdivision plat to the Approving
Body conditioned upon the deposit in escrow, via Letter of Credit or cash, of the estimated costs of the
adjacent unimproved street and utility improvements in-lieu of the actual construction of said facilities.
Any escrow, without interest, shall be applied against any assessment for improvements levied on such
property, but shall not be deemed to release such property from liability for any future costs assessed
which exceed the escrow.
3. One and Two Lot Residential Subdivisions – If a proposed residential subdivision contains only one or
two lots and the developer does not own any contiguous property, in lieu of actual construction, the
developer shall pay the applicable perimeter street costs in accordance with the General Infrastructure
Policy contained elsewhere in this Land Development Code for the initial one hundred feet of street
frontage. The applicable perimeter street costs shall be reduced 0.2% per linear foot of frontage in
excess of one hundred feet, not to exceed fifty percent of the applicable additional street frontage.
Exemption: A lot platted under this Section that contains an existing single-family dwelling at the time
a subdivision plat application is filed with the City and the lot is situated within a zoning district that
allows single-family residential uses, said lot shall have an automatic exemption from the perimeter
street costs, provided that existing perimeter street facilities are sufficient to assure the safe, effective
and orderly movement of traffic in and about the subdivision and utility services are adequate to serve
the development. The following notation shall be placed on the plat: “Any future divisions of these lots
will require full compliance with the unimproved street requirements applicable at the time of any
subsequent re-platting.”
Section 9.17 Street Design Criteria
A. Street Functional Classification – All streets shall be designed in accordance with the functional
classification shown on the most recent version of the Master Thoroughfare Plan and the following:
Colleyville, Texas, Land Development Code
Chapter 9 – Subdivision Design & Public Facilities Page 9 -8
Functional Classification of Streets
Street
Classification Functions - Uses
Local
Carries traffic from residential and commercial areas to collector streets and
interconnects individual sites. Local streets carry light traffic volumes and trips are of a
short duration.
Collector
Major
Minor
Carries traffic from local streets to arterial streets. Uses served would include medium
and high density residential, limited commercial facilities, elementary schools, some
small offices and as direct access within industrial parks. Collector streets also carry
heavy traffic to major commercial and industrial facilities from arterial streets. Uses
would include office parks, industrial parks, and community level commercial facilities.
Arterial
Major
Minor
The main function of an arterial is to carry traffic from on urban area to another. The
arterial streets serve the major activity centers of urbanized areas. An arterial street is
used for longer urban trips and carries a high portion of the total traffic with a minimum
of mileage.
B. Street Design
1.In-General – Streets shall be designed with due regard to topography, with due consideration of the
abutting uses, and the anticipated destination of traffic and traffic volumes at full development of the
neighborhood. Where necessary to prevent traffic congestion and to ease the movement of vehicles
to and from principal traffic generators, additional right-of-way width or other special design shall be
provided. Where topographical conditions make other treatment necessary to secure the best overall
design, these standards may be modified by the Director of Public Works or designee..
2.Street Continuity – The street layout shall provide for the continuation of the collector street system as
shown on the Master Thoroughfare Plan. Streets shall provide connection to streets in adjacent
subdivisions, but local streets shall be designed so as to discourage use by through traffic and to require
the minimum number of streets necessary for convenient and safe access to property.
3.Curvilinear Streets Encouraged - The developer is encouraged to consider curvilinear, cul-de-sac, and
loop street designs where such use would result in a more functional layout and not necessarily adhere
to a rigid rectangular street pattern.
4.Right-of-way Widths – Every subdivision plat shall dedicate sufficient right-of-way to comply with the
requirements of the Master Thoroughfare Plan. The right-of-way widths shall be designed for the
intended use and anticipated traffic volume at optimum development of the area served. Additional
right-of-way may be required at street intersections and to provide for left and right turn lanes at high-
volume intersections.
5.Cul-de-sac Lengths – No street shall be designed as a permanent dead-end street, but shall be
designed to incorporate a cul-de-sac which complies with this Section. (O-00-1261 / 12-19-00)
a.Diameter – A cul-de-sac street shall be provided at the closed end with a minimum property line
right-of-way diameter of one hundred feet, and a pavement turn-around with a minimum outside
diameter of eighty feet (80’). (O-00-1261 / 12-19-00)
b.Length – No cul-de-sac street shall exceed six hundred feet (600’) in length, unless additional right-
of-way width and additional pavement width are provided as required in this Section. Furthermore,
no cul-de-sac street shall exceed the maximum length of one-thousand two hundred feet (1,200’).
For purpose of this regulation, cul-de-sac length shall be measured along the centerline of the cul-
de-sac from the intersecting street right-of-way line to the center point of the cul-de-sac. (O-00-1261
/ 12-19-00)
c.Width – A cul-de-sac street shall have a minimum right-of-way width of fifty feet (50’) and a minimum
pavement width of thirty-one feet (31’), back-to-back of curb. However, a cul-de-sac street which
exceeds six-hundred feet (600’) in length shall have a minimum right-of-way width of fifty-six feet
(56’) and minimum pavement width of thirty-six feet (36’), back-to-back of curb. (O-00-1261 / 12-19-00)
Colleyville, Texas, Land Development Code
Chapter 9 – Subdivision Design & Public Facilities Page 9 -9
d.Maximum Number of Lots – The maximum number of single-family lots served on a cul-de-sac
street shall be as shown in the following table: (O-00-1261 / 12-19-00)
Maximum SF Residences Served on Cul-de-sac
District Max. Number of Lots Served
AG 5
RE 5
R-40 10
R-30 10
R-20 12
R-15 12
PUD-R 12
e.Temporary Turn-Around – A temporary turn-around is required when a street is temporarily dead-
ended and is longer than one-hundred and fifty (150) feet, as measured from the intersecting street
right-of-way line. The temporary turn-around shall be within a temporary easement and constructed
of asphalt or concrete. (O-00-1261 / 12-19-00)
6. Temporary Dead-End Streets - Temporary dead-end streets shall have provision for future extension
of the street and utilities and, if a temporary cul-de-sac is utilized, a reversionary right to the land
abutting the turnaround for excess right-of-way shall be provided.
7.Stub-outs for Future Extensions - Permanent dead-end roads shall not be allowed. The street layout
shall be extended to the tract boundary to provide for future access into adjoining tracts to assure
adequate neighborhood circulation unless: 1) prevented by topography or other physical conditions; or
2) the City Council determines that the extension is not necessary for future development of adjacent
tracts. In general, these extensions should be not more than one thousand (1,000) feet apart.
8.Pavement Required - All street surfaces within or abutting the proposed subdivision shall be paved,
with curbs and gutters installed, and constructed in accordance with the standards and specifications
contained elsewhere in this Land Development Code.
9.Frontage Access Road - Where a subdivision abuts or contains an existing or proposed collector street
or railroad right-of-way or abuts a commercial or industrial land use, the City may require a frontage
street approximately parallel to and on each side of such right-of-way to separate through and local
traffic, or reverse frontage with screen planting contained in a non-access reservation along the rear
property line, deep lots with rear service alleys, or equivalent treatment as may be necessary for
adequate protection of residential properties.
10.Half Streets - Half streets shall be prohibited, except where essential to the reasonable development
of the subdivision in conformity with the other requirements of these regulations, and where the City
Council finds it will be practicable to require the dedication of the other half when the adjoining land is
subdivided, the other half of the street shall be platted within such tract.
11.Number of Subdivision Entryways – Every subdivision shall be designed to provide sufficient access
into the development to accommodate anticipated traffic demands and to provide for emergency public
services using the criteria contained in this Section. (O-01-1280 / 08-08-01)
a. Where a proposed subdivision, or cul-de-sac street, contains more than twelve (12) lots, the
development shall provide for two entryways as follows:
Colleyville, Texas, Land Development Code
Chapter 9 – Subdivision Design & Public Facilities Page 9 -10
i.The development shall provide one street entryway and one emergency access easement.
The emergency access easement shall be located on an adjacent or opposite side of the
subdivision from the main entryway. The widths of the right-of-way and driving surfaces of the
street entryway and the emergency access easement shall be in accordance with the standards
contained elsewhere in this Land Development Code, or
ii.The development shall provide two street entryways separated not less than one-hundred
feet between the centerlines of the driving surfaces. The widths of the right-of-way and
driving surfaces of the two entryways shall be in accordance with the standards contained
elsewhere in this Land Development Code, or
iii. The development shall provide a divided entryway and one emergency access easement. The
driving surfaces of the divided entryway shall be separated by a median not less than ten (10)
feet in width and provide for one-way traffic. The widths of the right-of-way and driving surfaces
of the divided entryway shall be in accordance with the standards contained elsewhere in this
Land Development Code. The emergency access easement shall be located on an adjacent
or opposite side of the subdivision from the main entryway and be constructed in accordance
with the standards contained elsewhere in this Land Development Code.
b. If it is physically impractical or otherwise impossible to provide two entryways or to incorporate an
emergency access easement into the development in accordance with the above stated
requirements, the following alternative may be considered by the approving body:
i.A single pavement width of forty-one (41) feet shall be constructed. Said pavement shall
extend back from the intersecting street right-of-way a minimum distance of one-hundred (100’)
feet. All residences within the subdivision shall contain automatic fire-sprinkler systems.
c. If it is physically impractical or otherwise impossible to comply with the above-stated requirements,
an alternative design may be submitted to the City Council for consideration. The approving body
may approve the alternate design if it finds that the above-stated requirements can not be satisfied
and that all efforts have been made by the developer to comply with said requirements.
12.Reverse Curves - Between reverse curves there shall be a tangent section of centerline not less than
one hundred feet (100’) long.
C. Intersections
1. Streets shall be laid out so as to intersect as nearly as possible at right angles. A proposed intersection
of two (2) new streets at an angle of less than seventy-five (75) degrees shall not be acceptable.
2. Proposed new intersections along one side of an existing street shall, wherever practicable, coincide
with any existing intersections on the opposite side of such street Not more than two (2) streets shall
intersect at any one point unless specifically approved by the City.
3. Street jogs with centerline offsets of less than one hundred thirty-five (135) feet shall not be permitted.
4. Local streets intersecting a collector street or larger shall have a tangent section of centerline at least
fifty (50) feet in length measured from the right-of-way line of the collector street; however, no such
tangent is required when the minor street curve has a centerline radius greater than four hundred (400)
feet with the center located on the collector street right-of-way line.
5. At local street intersections, the property line corner shall be rounded by an arc having a radius of
twelve (12) feet. This radius shall be increased when the smallest angle of intersection is less than
eighty (80) degrees. At intersections of streets with major and collector streets the property line corners
shall be rounded by an arc having a radius of twenty-five (25) feet. The Director of Public Works or
designee may approve comparable cut-offs or cords in place of rounded corners.
Colleyville, Texas, Land Development Code
Chapter 9 – Subdivision Design & Public Facilities Page 9 -11
6. Where practical, spacing of intersections along collector streets shall be at least 500 feet apart.
D. Alleys – Alleys shall be provided in commercial and industrial districts and at the rear of multifamily
residential building sites for adequate circulation. Where approved by the Fire Marshal, an emergency
access easement not less than twenty-four feet (24’) in width shall be provided for emergency vehicle
access in lieu of any alley. Alleys should intersect streets at right angles or radially to curved streets where
sharp changes in alignment cannot be avoided. Property line corners shall be cut off fifteen feet (15’) on
each side to permit safe vehicular movement. Dead-end alleys shall be prohibited except where prior
development of land adjoining the subdivision permits no other reasonable design; under such
circumstances alleys shall be provided with turnaround or back-around facilities at the dead-end adequate
to permit clear maneuvering of sanitation trucks, utility service vehicles and emergency vehicles. Alleys
shall be not less than the following widths:
1. Twenty feet (20’) where residential building sites are provided on both sides;
2. Twenty-two feet (22’) wherever residential development abuts commercial or industrial areas;
3. Twenty-four feet (24’) where commercial or industrial development abuts on both sides.
Section 9.18 Easements
A. Easements – Easements for drainage and utility construction, service, and maintenance shall be provided
in locations approved by the City and affected utilities according to the following standards:
1. Easement for the use of public utilities of not less than seven and one-half (7.5') feet in width shall be
provided on each lot and extend along the entire length of the rear property line. Easements shall
connect with easements already established on adjoining properties or extend to connect with a public
right-of-way. No lot shall be shown with an easement which prevents proper development and full
utilization of the lot as a suitable building site for the intended zoning district.
2. For lots of more than two hundred (200) feet deep, the utility easement shall be not less than sixteen
(16) feet wide.
3. The width of any drainage easement shall be determined by the Director of Public Works or designee
or in accordance with the need for drainage improvements established by any drainage study.
4. All utility easements shall be dedicated as utility and/or drainage easements.
5. When an easement is granted for public purposes as a separate instrument, the following statement of
restrictions shall be placed in dedication instrument:
Utility Easements
Any public utility, including the City of Colleyville, shall have the right to move and keep moved all or part of any
building, fences, shrubs, other growths or improvements which in any way endanger or interfere with the
construction, maintenance, or efficiency of its respective systems on any of the easements shown on the plat;
and any public utility, including the City of Colleyville, shall have the right at all times of ingress and egress to and
from and upon said easements for the purpose of construction, reconstruction, inspection, patrolling, maintaining
and adding to or removing all or part of its respective systems without the necessity at any time of procuring the
permission of anyone.
B. Easements Adjacent to State Highways – When a proposed water or sewer line or drainage facility will be
placed adjacent to a public road maintained by the Texas Department of Transportation, a separate specific
use easement shall be provided for each utility or drainage facility.
C. Emergency Access Easements – Emergency access easements shall have a clear unobstructed width to
accommodate a pavement section of not less than twenty-four (24) feet in width. The emergency access
easement shall connect at each end to a dedicated public street or shall have a suitable size turnaround at
the dead-end, and appropriate turning space at inside corners to permit free movement of emergency
7501
200202204
7315
7309
7207
7404
7101
7307
7309
7401
7403
7405
7407
7409
201 203
205
7103
204202
200
7503
7603
7503
7501 7500
7201
7203
7205
7207
7209
7301
7303
7100
205203201103
101
7600
7602
7603
76017600
7102
7602101
7601
100 102 104 106
107
105103
7200
101
7202
7204
7302
7308
7310
7400
7600
7602201203205
301
302
301
101
200
108
7204
401117113
109
105 101
7109
7125
317
7600
760176007604
205
406
7506
75047503
7505
7209
202 206 210 7017 70127099
7301
7305
7309
7313
7317
7212
7300
304
304
7204
204
116
7400
104
7301
7215
210
315JOHN MCCA
IN
RDTILLMAN HILL RDMADIS
O
N S
Q
MONTICELLO PKWYS T I L L W A T E R CIR JEFFERSON CIRWILLIAMSBURG CT
ADAMS C T
BANDIT TR
HARDY LN
K
Parcels to be notified
Buffer
Subject Property
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC25-001
7316 John McCain Road
Notification Map
NOTICE OF PUBLIC HEARING
«Owner_Name»
«Owner_Address»
«Owner_City» «Owner_Zip»
The City of Colleyville has scheduled public hearings concerning the below referenced request on the
following dates and location:
Planning and Zoning Commission Meeting: Monday, February 10, 2025 at 7:00 p.m.
City Council Meetings: Tuesday, March 4, 2025 & Tuesday, March 11, 2025 at 7:00 p.m.
3rd floor of City Hall, 100 Main Street, Colleyville, Texas
Request: Consideration of a Rezoning from AG Agricultural to R-30 Single-
Family Residential and R-40 Single-Family Residential districts on
Tracts 4A2 & 4B2, 4A3 & 4B3, Abstract 295, William E. Crooks
Survey, being located at 7316 & 116 John McCain Road. The request is
to rezone the property for a new 12 lot single-family subdivision zoned
R-30 and R-40 Single Family Residential.
Zoning Case:ZC25-001
Applicant:Curtis Young, Sagegroup
Owner: Dale M. Holt
Location:7316 & 116 John McCain Rd
Property Description:Tracts 4A2 & 4B2, 4A3 & 4B3, & 4E, Abstract 295, William E. Crooks Survey
Present Zoning:AG Agricultural
This notice has been sent to all owners of real property within 500 feet of the request as such ownership appears on the last approved tax roll and all homeowners associations within 1000 feet. Approval by the Planning and Zoning Commission serves as a recommendation to the City Council and is not a final action on the request. Denial of the proposal by the Commission is final, unless the applicant submits a written notice of appeal within 10 days from the date of action by the Commission. If appealed, the request will
be placed on the next available City Council agenda as listed above. Rezoning requests, zoning
amendments and conditions recommended by the Commission for approval by the City Council may be more restrictive than those described in this notice.
All interested persons are encouraged to attend the public hearing and express their opinions on the zoning
change request. If you are unable to attend, but wish to have your opinions made a part of the public record,
please submit written comments prior to the public hearing, to the address or email below:
Community Development Department
City of Colleyville
100 Main Street
Colleyville, TX 76034
Citizenletters@colleyville.com
NOTICE OF PUBLIC HEARING
If the property owners of 20% or more of the land within the 200 foot notification area file a written protest
prior to the public hearing, State law provides that the approval of the zoning change request shall require
the approval of a super majority vote by City Council.
The application is on file for public examination in the Community Development Department at 100 Main
Street, Colleyville, Texas 76034. A brief project description can be found online on the Agenda Packet and
Active Development Case map (please use your phone’s camera to scan QR code below):
For additional information, please contact the Community Development Department at 817.503.1050.
Please reference the zoning case number when requesting information.
Kris Potts
Planner
1
Notification List
Owner_Name Situs_Addr
COLGAN, GREGORY D 7501 TILLMAN HILL RD
REAKA, PETER U 200 BANDIT TR
KOOP, MITCHELL 202 BANDIT TR
RAGAN, THERON A 204 BANDIT TR
KENT, ROBERT 7315 JOHN MCCAIN RD
WALKER, GRADY M 7309 JOHN MCCAIN RD
ATHERTON, JAY W 7207 JOHN MCCAIN RD
KOONCE, TIMOTHY J 7404 JOHN MCCAIN RD
STEHLING, TRENT 7307 MONTICELLO PKWY
HINTON, SHARON 7309 MONTICELLO PKWY
OSBORNE, DONALD 7401 MONTICELLO PKWY
HUNTER, MARK E 7403 MONTICELLO PKWY
WEASNER, JOHN 7405 MONTICELLO PKWY
FRANCIS, BOBBY 7407 MONTICELLO PKWY
SORRELL, ANDREW 7409 MONTICELLO PKWY
SALSBURY, BRUCE 201 MADISON SQ
CHANG, WESLEY EN-TSE 203 MADISON SQ
SCHEFFE, SCOTT A 7103 MONTICELLO PKWY
ANDRE, TERRI 200 MADISON SQ
ALAWY, AHMED 7201 MONTICELLO PKWY
DAVIS, JOHN ROGER 7203 MONTICELLO PKWY
KNOX, LARRY 7205 MONTICELLO PKWY
GALLEGOS, ELVIS 7207 MONTICELLO PKWY
ROBERTS, ROBERT 7209 MONTICELLO PKWY
SATTLER, DAVID 7301 MONTICELLO PKWY
ONEILL, LIAM 7100 MONTICELLO PKWY
LEWIS, LARRY 205 ADAMS CT
LAMB, CHARLES A 203 ADAMS CT
WILLSON, JOSHUA A 201 ADAMS CT
MARKLE, MITCHELL C 103 ADAMS CT
AIRIS, MARK 101 ADAMS CT
SHOMPER, JASON 7102 MONTICELLO PKWY
VENTURA, PAOLA MELO 104 WILLIAMSBURG CT
BRASWELL, JAMES L 106 WILLIAMSBURG CT
AWALT, TIFFANY 107 WILLIAMSBURG CT
MERRIFIELD, WILLIAM 105 WILLIAMSBURG CT
CHAPMAN, MARK NOEL 103 WILLIAMSBURG CT
BEAMAN, TED A 7200 MONTICELLO PKWY
COMPTON, SINA 101 WILLIAMSBURG CT
FLETCHER, CRISTI 7202 MONTICELLO PKWY
HUANG, SHU-MING 7204 MONTICELLO PKWY
MONTICELLO HOMEOWNERS ASSN 7302 MONTICELLO PKWY
SHIELDS, LARRY D 7308 MONTICELLO PKWY
BOLIVAR, JOSE 7310 MONTICELLO PKWY
COOPER, JERRY R 7400 MONTICELLO PKWY
DENNY AND JUDY NEWGREN REVOCABLE TRUST 200 JOHN MCCAIN RD
VAN HORNE, EDWARD 108 JOHN MCCAIN RD
BELL, APRIL 7204 JOHN MCCAIN RD
PELTIER, ANGELA 205 BANDIT TR
DAWSON FARMS LLC 7209 JOHN MCCAIN RD
WAGNER, FREDERICK V 7305 CHANEL CT
CROWE REVOCABLE TRUST 7309 CHANEL CT
REDDY, BIBAS 7313 CHANEL CT
O'NEAL, BRIAN 7317 CHANEL CT
VISIONS SOUTHWEST 10 LP 7321 CHANEL CT
JUDON, MATTHEW 7212 JOHN MCCAIN RD
MARTINEZ GRULLON, JUAN 7300 JOHN MCCAIN RD
2
Notification List
TRINITY CHRISTIAN CENTER OF SANTA ANA INC 304 JOHN MCCAIN RD
NEFF, T BRENT 204 JOHN MCCAIN RD
HOLT, DALE M 116 JOHN MCCAIN RD
JONES, MARK 7316 JOHN MCCAIN RD
ESSEX MANOR TRUST 7400 JOHN MCCAIN RD
HIGHTOWER, ROXANNE S 104 JOHN MCCAIN RD
BILLINGS, FLORENCE L 7301 JOHN MCCAIN RD
OLD GROVE ADDITION COURTESY NOTICE
WESTMONT ADDITION COURTESY NOTICE
CHANEL COURT COURTESY NOTICE
VANGUARD ESTATES ADDITION COURTESY NOTICE
MONTICELLO ADDITION-COLLEYVLLE COURTESY NOTICE
GRAPEVINE COLLEYVILLE ISD STATE REQUIRED
CURTIS YOUNG APPLICANT
7501
200202204
7315
7309
7207
7404
7101
7307
7309
7401
7403
7405
7407
7409
201
203
205
7103
200
7201
7203
7205
7207
7209
7301
7303
7100
205203201103
101
7600
7102
100 102 104 106
107
105103
7200
101
7202
7204
7302
7308
7310
7400
200
108
7204
7109
205
75047503
7209
7212
7300
304
304204
116
7400
104
7301
7215 JOHN MCCAIN RDMADIS
O
N S
Q
MONTICELLO PKWYWILLIAMSBURG CT
ADAMS C T
BANDIT TR
HARDY LN
K
Subject Property
Opposing
Buffer_Protest
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC25-001
7316 John McCain Road
Opposition Map
List of Opposing Properties
Owner's NameAddress Percentage
VAN HORNE, EDWARD108 JOHN MCCAIN RD 4.42%
Address Count : 1 Total Percentage: 4.42%
Page 1 of 1 Date : 2/3/2025 3:43 PM
ORDINANCE O-25-XXXX
AMENDING THE ZONING ORDINANCE AND THE OFFICIAL
ZONING MAP OF THE CITY OF COLLEYVILLE, TEXAS, BY
CHANGING THE ZONING ON 11.81 ACRES, BEING TRACTS 4A2 &
4B2, 4A3 & 4B3, & 4E, ABSTRACT 295, WILLIAM E. CROOKS
SURVEY, BY AUTHORIZING A REZONING FROM AG
AGRICULTURAL TO R-40 SINGLE-FAMILY RESIDENTIAL AND R-
30 SINGLE-FAMILY RESIDENTIAL DISTRICTS; PROVIDING A
PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO THOUSAND
DOLLARS ($2,000.00) AND PROVIDING AN EFFECTIVE DATE
WHEREAS, the City of Colleyville has received an application for a
rezoning from AG Agricultural to R-40 Single-Family
Residential and R-30 Single Family Residential districts
under Case No. ZC25-001; and
WHEREAS, the City of Colleyville deems it necessary, for the purpose
of promoting the health, safety, morals, or general welfare
of the City to amend the City’s zoning ordinance; and
WHEREAS, the Planning and Zoning Commission, has given
reasonable consideration to, among other things, the
character of the City’s zoning districts and their peculiar
suitability for particular uses, with a view to conserving the
value of buildings and encouraging the most appropriate
use of land throughout the City; and
WHEREAS, the City Council is of the opinion that the change in zoning
provided for herein should be made, in compliance with
the City Charter, and state law with reference to changes
to zoning classifications under the City’s zoning ordinance
and zoning map, having given the requisite notices
required by law and having held public hearings affording
all interested persons and property owners a full and fair
opportunity to be heard.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF
THE CITY OF COLLEYVILLE, TEXAS:
Sec. 1. THAT the Comprehensive Zoning Ordinance of the City of
Colleyville, Texas, be, and the same is hereby amended by
authorizing a rezoning from AG Agricultural to R-40 Single-Family
Ordinance O-25-xxxx
Page 2 of 3
Residential and R-30 Single-Family Residential on 11.81 acres,
being Tracts 4A2 & 4B2, 4A3 & 4B3, & 4E, Abstract 295, William E.
Crooks Survey, located at 7316 and 116 John McCain Rd, as
depicted on the attached as Exhibit “A”.
Sec. 2. THAT the above described tract of land shall be used only in the
manner and for the purposes provided by the Comprehensive
Zoning Ordinance of the City of Colleyville as heretofore amended,
and as amended herein.
Sec. 3. THAT the above described tract of land shall be subject to the
following conditions:
1. GENERAL
a. As depicted in the attached Exhibit “A” and Exhibit “B”
Sec. 4. THAT any person, firm or corporation violating any of the provisions
or terms of this ordinance shall be subject to the same penalty as
provided for in the Comprehensive Zoning Ordinance of the City of
Colleyville, and upon conviction shall be punishable by a fine not to
exceed the sum of Two Thousand Dollars ($2,000.00) for each
offense.
Sec. 5. THAT if any section, paragraph, subdivision, clause, phrase or
provision of this ordinance shall be judged invalid or
unconstitutional, the same shall not affect the validity of this
ordinance as a whole or any portion thereof other than that portion
so decided to be invalid or unconstitutional.
Sec. 6. THAT in addition to and accumulative of all other penalties, the City
shall have the right to seek injunctive relief for any and all violations
of this ordinance.
Sec. 7. THAT this ordinance shall take effect immediately from and after
its passage subject to the publication of the caption, as the law or
charter in such cases may provide.
AND IT IS SO ORDERED.
The first reading and public hearing being conducted on the 4th day of
March 2025.
Ordinance O-25-xxxx
Page 3 of 3
The second reading and public hearing being conducted on the 11th day
of March 2025.
PASSED AND APPROVED BY A VOTE OF _ AYES, _ NAYS, AND _
ABSTENTIONS ON THIS THE 11TH DAY OF MARCH 2025.
Mayor Bobby Lindamood Mayor Pro Tem Brandi Elder
Place 2, Mark Alphonso Place 5, Kimberly Holt Gunderson
Place 3, Scotty Richardson Place 6, Tim Raine
Place 4, Ben Graves
ATTEST: CITY OF COLLEYVILLE
Christine Loven, TRMC Bobby Lindamood
City Secretary Mayor
APPROVED AS TO FORM:
Whitt Wyatt
City Attorney
Exhibit “A” - Location and Zoning Map
Exhibit “B” – Site Plan
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
BRIEFING
Agenda Number 2d Agenda Date 2/10/2025 Number -
Type Public Hearing Agenda Items
Department Community Development
Title
Consideration of a change to the Land Development Code, Chapter 3, Section 3.27,
Accessory Building Regulations and Residential Carport Regulations
Explanation
The City Council has directed staff to prepare an amendment to the Land Development
Code Chapter 3, Section 3.27, Accessory Building Regulations and Residential Carport
Regulations. The amendment will remove the requirement of a Special Use Permit (SUP)
for carports which meet all the section requirements and are located completely to the
rear of the house or not visible from the street. Carports proposed on corner lots will
still require an SUP approval.
Staff Recommendation: Staff recommends approval of the proposed amendment.
Recommendation
Approve
Attachments
1. Draft Ordinance Language
2. Draft Ordinance
Section 3.27 Accessory Buildings and Residential Carport Regulations
The following regulations shall govern the location, size and use of accessory buildings:
A. Accessory Buildings Located in Residential Zoning Districts (O-00-1223 / 07/18/00)
1.Permit Required:
a. A building permit shall be required for any accessory building which exceeds one hundred and twenty
(120) square feet. However, all accessory buildings containing 120 square feet or less shall comply
with the height and setback requirements of this Section. An accessory building shall only be allowed
as an incidental structure to a principle building unless the accessory building is located in the
Agricultural District.
b. For the purpose of this Section, the term accessory building shall include detached residential garages,
pool houses, accessory dwellings, gazebos, cabanas, or other shade structures. Exception: structures
for specific use as playground assemblies and/or playhouses shall be exempt provided that minimum
five (5) feet setbacks from property lines are maintained.
2.Maximum Size and Number of Buildings:
a. The maximum number of accessory buildings allowed per lot shall be three (3) buildings. In addition,
the combined square footage of all accessory buildings shall not exceed four percent (4%) of the
aggregate area of the lot. Exemption: Lots containing a minimum of 80,000 square feet shall be exempt
from the requirement for the maximum number of accessory buildings.
b. Accessory dwellings allowed by the Land Development Code shall be limited in size to be no more than
the most restrictive of the following:
1. Fifty percent (50%) of the primary structure;
2. The maximum allowed square footage for accessory buildings on the lot; or
3. No more than twelve hundred (1,200) square feet
c. For the purpose of this Section, the size of an accessory building shall be the square footage of each
floor, mezzanine, covered porch, or shade structure.
d. An application to exceed the total square footage authorized above may be approved as a Special Use
Permit (SUP).
e. An existing accessory building may be remodeled or expanded provided the combined square footage
of all accessory buildings does not exceed the maximum square footage allowed. However, a legally-
existing accessory building which exceeds the maximum square footage allowed may be remodeled or
replaced with a new accessory building, but not expanded or increased in height.
f. There shall be no physical connection between accessory buildings and a minimum separation of three
(3) feet between accessory buildings.
3.Setbacks:
a. No accessory building shall be allowed, erected, or located forward of the front façade of the primary
dwelling. Exemption: Lots containing a minimum of 80,000 square feet shall be exempt from this
requirement.
b. No accessory building shall be erected in any required yard, as defined in Chapter 2 – Definitions,
except as set forth herein.
c. Attached accessory buildings – Accessory buildings erected ten (10) feet or closer to the principal
building shall be considered attached, and shall comply with the setback lines established for the
applicable zoning district. For the purpose of this regulation, the distance between buildings shall be
measured between the nearest wall surfaces. Exception: Open structures (open on at least 2 ¾ sides),
such as patio covers, shall be allowed to extend into the required rear yard setback a maximum of 10
feet.
d. Detached accessory buildings – A detached accessory building shall comply with the setback lines
established for the applicable zoning district, unless the accessory building is located totally behind the
rear of the principal building, then it shall not be placed closer than five (5) feet to any side or rear lot
line.
4.Maximum Height: No accessory building shall penetrate a vertical height envelope defined as being a point
five feet from a side or rear lot line and extending vertically 8 feet to a point, then extending at a 45o angle
to the allowed height of the zoning district. For clarification, structures shall be measured at grade and shall
not exceed the maximum height of the zoning district.
5. Permitted Uses: The use of an accessory building shall be consistent with the permitted uses of the
applicable zoning district. No accessory building shall be used for dwelling purposes (the act of occupying
a structure – with or without a kitchen) other than for an accessory dwelling, where permitted by the district
regulations or Special Use Permit. No accessory building or accessory dwelling shall be rented.
6. Special Use Permit Provision: Any request for a building permit for an accessory building which does not
meet the criteria in this Section shall only be authorized after approval of a Special Use Permit by the City
Council using the procedures contained elsewhere in this Land Development Code.
B. For Accessory Buildings Located in Non-residential Zoning Districts
1. No accessory building shall be erected in any required yard area except as set forth by this section.
2. No accessory building shall be erected within ten (10) feet of any other building unless such accessory
building is used as a commercial kiosk, in which case such commercial kiosk cannot be located within fifty
(50) feet of another building.
3. Commercial kiosks as accessory uses and/or buildings may be located within approved nonresidential
districts subject to the following conditions:
a. Maximum size of two hundred-fifty (250) square feet.
b. No inside sales or service or drive in sales or service; walk-up and/or drive-up service permitted.
c. Exterior walls shall be of at least seventy-five percent (75%) masonry, glass, or other equivalent
material, provided metal material does not exceed twenty-five percent (25%) of the exterior walls.
d. Located within required setbacks and in conformance with this section.
e. Located in such a manner as to not impede, impair or endanger vehicular traffic on the property where
the kiosk is located and for vehicular traffic ingressing from and egressing to public rights-of-way.
f. Submission of an acceptable site plan shall be required for consideration of the issuance of a building
permit unless a current valid Certificate of Occupancy exists.
g. Limited to one (1) kiosk per platted plot.
C. Residential Carport Regulations – Carports located in zoning districts which permit single family residential
dwellings shall comply with the regulations contained in this section.
1.Approval by Special Use Permit Only: In accordance with the Special Use Permit procedures contained in
this Chapter of these zoning regulations, no carport shall be built in the City of Colleyville without approval
by the City Council for a Special Use Permit to construct a carport in a zoning district that permits single
family residential dwellings. Special Use Permit Provision: Any request for a building permit for a carport
which does not meet the criteria in this Section shall only be authorized after approval of a Special Use
Permit by the City Council using the procedures contained elsewhere in this Land Development Code. If all
criteria is met then a Special Use Permit is not required. EXCEPTION: All carports on a corner lot shall
require approval of a Special Use Permit.
2.Carport Standards: A carport shall comply with the following regulations, unless the City Council in
approving a Special Use Permit for a carport has imposed other requirements necessary in the particular
case to protect the public interests.
a.Size: A carport shall not exceed 480 square feet in area. The longest dimension on a carport shall not
exceed 24 feet.
b.Height: A carport shall not exceed a maximum height of 15 feet and no taller than the primary structure.
The height shall be measured from the finished grade to the highest point of the roof.
c.Setbacks:
i. A carport located within ten (10) feet of the principal building shall comply with the front, side and
rear yard setbacks of the zoning district provided all of the following conditions are satisfied:
(1) The carport is located completely to the rear of the house OR is not visible from the street;
(2) Is not proposed on a corner lot; and
(3) The distance shall be measured between the two closest points of the carport and principal
building.
ii. A carport located 10 feet or more from a principal building may extend into a required side or rear
yard, provided all of the following conditions are satisfied:
(1) every part of such carport is unenclosed except for necessary structural supports;
(2) no part of the carport is less than five (5) feet from a side or rear lot line; and
(3) the carport is located completely within the rear yard area as defined in these zoning
regulations; and
(4) the carport shall not be visible from the street.
d.Maximum Number Per Lot: one
e.Paving and Street Access:
The parking area of a carport shall be paved not less than nine feet (9’) by eighteen feet (18’) and
provide access to a public street right-of-way. Said access shall be a minimum of nine feet (9’) in width
and paved. All paved surfaces shall be either concrete, asphalt or pave-stone.
f.Design Criteria:
i. Roof - Carports shall have a pitched roof of at least 2:12. Flat roofs shall be prohibited.
ii. Posts - Posts shall be clad or finished of brick, stone, cedar or decorative metal, such as metal
lattice. For purpose of this requirement, decorative metal shall consist of twenty-five (25) percent
opaque surfaces. The dimension of each post as viewed from each primary elevation shall not
be less than eight inches (8”) or more than forty-eight inches (48”). Any carport with two or more
elevations that exceed the 48-inch criteria shall be considered an accessory building and be
regulated as such. Cedar posts shall be wrapped using masonry stone or brick from the base to
at least 50% of the post height. The exposed portion of the cedar post shall be a minimum of 8
inches.
g.Adequacy of Plans and Specifications:
The applicant requesting a Special Use Permit to construct a carport shall submit plans and
specifications of the proposed carport for review. Said plans and specifications shall contain sufficient
information to allow the City Council to determine that the proposed carport complies with these
regulations and the City Council may require additional information when necessary to clarify the
applicant’s request. At a minimum, the drawings shall contain a plot plan, elevation views and a
description of the construction materials.
ORDINANCE O-25-
AN ORDINANCE OF THE CITY OF COLLEYVILLE, TEXAS, AMENDING
CHAPTER 3, SECTION 3.27 ACCESSORY BUILDINGS AND RESIDENTIAL
CARPORT REGULATIONS OF THE LAND DEVELOPMENT CODE;
PROVIDING A SAVINGS CLAUSE; PROVIDING A SEVERABILITY
CLAUSE; PROVIDING FOR INJUNCTIVE RELIEF; PROVIDING FOR A
PENALTY OF FINE NOT TO EXCEED TWO THOUSAND DOLLARS
($2,000.00) FOR EACH OFFENSE; AND PROVIDING AN EFFECTIVE
DATE
WHEREAS, the City Council of the City of Colleyville approved Ordinance O-
00-1214 on April 18, 2000, adopting the Land Development
Code; and
WHEREAS, the City of Colleyville desires to amend Chapter 3, Section 3.27
Accessory Building and Residential Carport Regulations of the
Land Development Code; and
WHEREAS, notice of a public hearing before the City Council was published
in a newspaper of general circulation in Colleyville at least 15
days before such hearing.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE
CITY OF COLLEYVILLE, TEXAS:
Sec. 1. THAT Chapter 3, Section 3.27 Accessory Building and Residential
Carport Regulations of the Land Development Code is hereby
amended to read as depicted in the attached Exhibit “A”.
Sec. 2. THAT any person, firm or corporation violating any of the provisions
or terms of this ordinance shall be subject to the same penalty as
provided for in the Comprehensive Zoning Ordinance of the City of
Colleyville, and upon conviction shall be punishable by a fine not to
exceed the sum of Two Thousand Dollars ($2,000.00) for each
offense.
Sec. 3. THAT if any section, paragraph, subdivision, clause, phrase or
provision of this ordinance shall be judged invalid or
unconstitutional, the same shall not affect the validity of this
ordinance as a whole or any portion thereof other than that portion
so decided to be invalid or unconstitutional.
Ordinance O-25-
Page 2 of 2
Sec. 4. THAT in addition to and accumulative of all other penalties, the City
shall have the right to seek injunctive relief for any and all violations
of this ordinance.
Sec. 5. THAT this ordinance shall take effect immediately from and after
its passage subject to the publication of the caption, as the law or
charter in such cases may provide.
AND IT IS SO ORDERED.
The first reading and public hearing being conducted on the 4th day of March
2025.
The second reading and public hearing being conducted on the 11th day of
March 2025.
PASSED AND APPROVED BY A VOTE OF ___ AYES, ___ NAYS, AND ___
ABSTENTIONS ON THIS THE 11TH DAY OF MARCH 2024.
Mayor Bobby Lindamood Mayor Pro Tem Brandi Elder
Place 2, Mark Alphonso Place 5, Kimberly Holt Gunderson
Place 3, Scotty Richardson Place 6, Tim Raine
Place 4, Ben Graves
ATTEST: CITY OF COLLEYVILLE
Christine Loven, TRMC Bobby Lindamood
City Secretary Mayor
APPROVED AS TO FORM:
Whitt L. Wyatt
City Attorney
Exhibit “A”
Chapter 3 – Land Use
Section 3.27 Accessory Buildings and Residential Carport Regulations
The following regulations shall govern the location, size and use of accessory buildings:
C. Residential Carport Regulations – Carports located in zoning districts which permit single family
residential dwellings shall comply with the regulations contained in this section.
1. Approval by Special Use Permit Only: In accordance with the Special Use Permit procedures
contained in this Chapter of these zoning regulations, no carport shall be built in the City of
Colleyville without approval by the City Council for a Special Use Permit to construct a carport in a
zoning district that permits single family residential dwellings. Special Use Permit Provision: Any
request for a building permit for a carport which does not meet the criteria in this Section shall only
be authorized after approval of a Special Use Permit by the City Council using the procedures
contained elsewhere in this Land Development Code. If all criteria is met then a Special Use Permit
is not required.
2. Carport Standards: A carport shall comply with the following regulations, unless the City Council
in approving a Special Use Permit for a carport has imposed other requirements necessary in the
particular case to protect the public interests.
a. Size: A carport shall not exceed 480 square feet in area. The longest dimension on a carport
shall not exceed 24 feet.
b. Height: A carport shall not exceed a maximum height of 15 feet. The height shall be measured
from the finished grade to the highest point of the roof.
c. Setbacks:
i. A carport located within ten (10) feet of the principal building shall comply with the front,
side and rear yard setbacks of the zoning district, be located completely to the rear of the
house, and not visible from the street. The distance shall be measured between the two
closest points of the carport and principal building.
ii. A carport located 10 feet or more from a principal building may extend into a required
side yard, provided all of the following conditions are satisfied:
(1) every part of such carport is unenclosed except for necessary structural supports;
(2) no part of the carport is less than five (5) feet from a side or rear lot line;
(3) the carport is located completely within the rear yard area as defined in these zoning
regulations; and
(4) the carport shall not be visible from the street.
d. Maximum Number Per Lot: one
e. Paving and Street Access:
The parking area of a carport shall be paved not less than nine feet (9’) by eighteen feet (18’)
and provide access to a public street right-of-way. Said access shall be a minimum of nine feet
(9’) in width and paved. All paved surfaces shall be either concrete, asphalt or pave-stone.
f. Design Criteria:
i. Roof - Carports shall have a pitched roof of at least 2:12. Flat roofs shall be prohibited.
ii. Posts - Posts shall be clad or finished of brick, stone, cedar or decorative metal, such as
metal lattice. For purpose of this requirement, decorative metal shall consist of twenty-
five (25) percent opaque surfaces. The dimension of each post as viewed from each
primary elevation shall not be less than eight inches (8”) or more than forty-eight inches
(48”). Any carport with two or more elevations that exceed the 48-inch criteria shall be
considered an accessory building and be regulated as such. Cedar posts shall be
wrapped using masonry stone or brick from the base to at least 50% of the post height.
The exposed portion of the cedar post shall be a minimum of 8 inches.
g. Adequacy of Plans and Specifications:
The applicant requesting a Special Use Permit to construct a carport shall submit plans and
specifications of the proposed carport for review. Said plans and specifications shall contain
sufficient information to allow the City Council to determine that the proposed carport complies
with these regulations and the City Council may require additional information when necessary
to clarify the applicant’s request. At a minimum, the drawings shall contain a plot plan, elevation
views and a description of the construction materials.