HomeMy WebLinkAboutPlanning and Zoning Commission-Agenda Packets-11/25/2024 (2)City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING
COMMISSION WORKSESSION
AGENDA
100 Main Street, Colleyville, Texas, 76034
MONDAY, NOVEMBER 25, 2024
EXECUTIVE CONFERENCE ROOM - THIRD FLOOR
6:15 P.M.
1.CALL TO ORDER
2.PRESENTATION AND DISCUSSION
2a Presentation and discussion of a Replat for Lot 1, Block A, Alverson
Addition, being located at 605 Beverly Drive, Case PC24-014
2b Presentation and discussion of an amendment to a Planned Unit
Development – Commercial Ordinance to allow for office and medical
office buildings, being Tract 1, Abstract 1154, R H McEwing Survey,
located at 8060 Precinct Line Road, Case ZC24-027
2c Presentation and discussion of a Special Use Permit to allow for a
Daycare Center on a portion of Lot 1, Block 1, Towne Center Animal
Hospital, located at 4313 Colleyville Boulevard, Case ZC24-028
2d Presentation and discussion of a change of zoning from AG
Agricultural to CC-1 Village Retail, being Tract 2P, Abstract 973,
Absalom J Lott Survey, located at 6312 Colleyville Boulevard, Case
ZC24-029
3. ADJOURNMENT
I hereby certify this agenda was posted on City Hall bulletin boards Thursday, November
21, 2024 by 5:00 p.m.
Jacquelyn Reyff
Planning Manager
A quorum of any Colleyville board, commission, or committee may be present at this
meeting. Any matter on this agenda may, at the discretion of the governing body, be
opened for public comment and discussion.
If you plan to attend this public meeting and have a disability that requires special
accommodations, please advise the City Secretary at least 48 hours in advance at
817.503.1133, and reasonable accommodations will be made to assist you.
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number 2a Agenda Date 11/25/2024 Number -
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a Replat for Lot 1, Block A, Alverson Addition, being
located at 605 Beverly Drive, Case PC24-014
Explanation
David Lewis, the applicant, has submitted a Replat for Lot 1, Block A, Alverson Addition,
approximately 0.979 acres, and zoned R-40 Single Family Residential. The request is to
plat the property. The property is currently a remainder of Block B of the Pleasant Oak
Estates and has never been platted individually.
Attachments
1. Aerial Map
2. Zoning Map
3. Plat Exhibit
4. Topographic Survey
704
700 704
800
705701
613
700
5710
5616
5706 5705
5703
5701 5700
5702
5704
5706
807805803801
5700
5702
5704
5812
5816
5820
404400316
56085604
402
5612
516512 6095
6001
5901
500
512
512508
511
600
601 605 609
608 612 708
705701
704
801 805
800
805601717801609705709701605
505
617
609
5705
5701
513509
601
600 604508504 608
513
5712
5808
5904
501
612
405
508 800 804608
608 612
616
500
700
702 704 708 800 804504508512600604
5704
400
6000
504500
BRANSFORD RDHUNTER LNTHERESALNGRANDOAKCTSHELTON DR
SUELLENC IR
O A K L E I G H L N
COLLEYVILLE TERR
LETA LN
BEVERLY DR
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC24-014
605 Beverly Drive
Aerial Map
704
700 704
800
705701
613
700
5710
5616
5706 5705
5703
5701 5700
5702
5704
5706
807805803801
5700
5702
5704
5812
5816
5820
404400316
56085604
402
5612
516512 6095
6001
5901
500
512
512508
511
600
601 605 609
608 612 708
705701
704
801 805
800
805601717801609705709701605
505
617
609
5705
5701
513509
601
600 604508504 608
513
5712
5808
5904
501
612
405
508 800 804608
608 612
616
500
700
702 704 708 800 804504508512600604
5704
400
6000
504500
BRANSFORD RDHUNTER LNTHERESALNGRANDOAKCTSHELTON DR
SUELLENC IR
O A K L E I G H L N
COLLEYVILLE TERR
LETA LN
BEVERLY DRR-40
R-10
R-10
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
PC24-014
605 Beverly Drive
Zoning Map
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number 2b Agenda Date 11/25/2024 Number -
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of an amendment to a Planned Unit Development –
Commercial Ordinance to allow for office and medical office buildings, being Tract 1,
Abstract 1154, R H McEwing Survey, located at 8060 Precinct Line Road, Case ZC24-
027
Explanation
Paul Moss, the applicant, has submitted a request for an amendment to a Planned Unit
Development - Commercial Ordinance, being Tract 1, Abstract 1154, R H McEwing
Survey, approximately 2.98 acres, and zoned PUD-C Planned Unit Development -
Commercial. The purpose of the request is to allow for office and medical office
buildings, rather than retail and restaurant uses.
Attachments
1. Aerial Map
2. Zoning Map
3. Statement of Planning Objectives
4. Site Exhibit
5. Original Ordinance O-18-2065
5920
5832
5916
5912
5908
5904
5900
5844
5840
5836
5924
6032
5935
5931
5927
5923
5919
5915
5911
5907
5903
5928
5849
5845
5841
5837
6000
6004 6028
5917
5921 5922
5918
5914
5910
5906
5835
5902
5846
5842
5838
5834
5800
5839
5843
5847
5901
5909
5913
5802
8090
8080
8070 8074
8078
8086
5908
5904
5900
5808
6218
6212
6208
6100
6204
6200
6112
5812
6108
6104
5912
8060
8060
8050
8000PRECINCT LINE RDSTERLING DRCRESCENT LNEMMASCTK
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC24-027
8060 Precinct Line Road
Aerial Map
5920
5832
5916
5912
5908
5904
5900
5844
5840
5836
5924
6032
5935
5931
5927
5923
5919
5915
5911
5907
5903
5928
5849
5845
5841
5837
6000
6004 6028
5921 5922
5918
5914
5910
5906
5835
5902
5846
5842
5838
5834
5800
5839
5843
5847
5901
5909
5913
5802
8090
8080
8070 8074
8078
8086
5908
5904
5900
5808
6105
6101
6218
6212
6208
6100
6204
6200
6112
5812
6108
6104
5912
6213
6209
6215
8060
8060
8050
8000PRECINCT LINE RDLAVACA TR
STERLING DRCRESCENT LNEMMASCTPUD-R
R-40
R-20
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC24-027
8060 Precinct Line Road
Zoning Map
TAK ENTERPRISES INC
8821 Davis Blvd., #220
Keller, Texas 76248
paul@marinabayhomes.net
817-431-5626
11/8/2024
City of Colleyville
Planning Dept.
100 Main Street
Colleyville, Texas 76034
Re: Proposed PD Amendment and Site Plan for 1.985 Acre Property
Dear Chris Pham
I am writing to provide details regarding the proposed amendment to the PD zoning ordinance
O-18-2065 for the 1.985-acre property located at 8060 Precinct Line Rd. Currently, the PD site
plan includes a restaurant of 3,609 square feet with 31 parking spaces and a professional office
building of approximately 9,512 square feet with 79 parking spaces. Each building is planned to
be situated on its own lot for ownership purposes, with each lot providing the required parking as
specified by the zoning ordinance.
The proposed amendment, as outlined in this application, would modify the site plan to include
three lots. Each lot would be designated for medical or professional office use. The proposed
buildings are as follows:
• Building A: 5,032 square feet
• Building B: 5,368 square feet
• Building C: 5,340 square feet
A shared fire lane and access drive will connect the three lots. Parking will be provided based on
the standard of 1 parking space per 200 square feet for medical or dental use, resulting in a total
of 82 parking spaces. We plan to implement a shared parking agreement between the three lots.
The architectural materials proposed for the buildings will include native stone, cement stucco,
aluminum storefront windows and doors, with pitched fiberglass shingle roofs in a hip style.
Trim will consist of painted cement fiberboard.
Landscaping will meet or exceed the requirements of the current PD site plan. A serpentine city
sidewalk will be installed along Precinct Line Road, and the landscape buffer along the road will
exceed the 20-foot minimum requirement. The parking lot will be landscaped in accordance with
city planning ordinances, and a 10-foot landscape buffer will be provided along the south and
east property lines. Maintenance of the landscaping will be managed by a Property Owners
Association (POA), which will be established by our company.
To ensure aesthetic and functional quality, ground-mounted AC units will be screened with
masonry walls, steel access gates, and landscaped features. Additionally, two monument signs
will be installed along the Precinct Line Road landscape buffer.
Development of the property will occur in phases, starting with the northernmost lot. Once the
first building is fully leased or occupied, development of the second lot will begin, followed by
the third. The buildings may be leased to multiple tenants or sold to a single occupant.
Please do not hesitate to contact me with any questions or for further clarification regarding this
proposal. We look forward to moving forward with this development and appreciate your
consideration.
Sincerely,
Paul Moss
N 03°16'15" E 100.24'N 05°30'54" W 45.28'S 88°08'58" W 255.79'S 03°03'53" E 344.82'N 00°44'00" W 200.00'N 04°44'15"W 8.63'PRECINCT LINE ROAD(R.O.W. VARIES)LOT 3, BLOCK 2
LAVACA TRAIL ADDITION
DOC.NO. D211238019
COMMERCIAL CC-2
LOT 4, BLOCK 2
LAVACA TRAIL ADDITION
DOC.NO. D217053885
D.R.T.C.T.
COMMERCIAL PUD-C
LOT 1, BLOCK 1
PRECINCT LINE RETAIL ADDITION
DOC.NO. D219154801
P.R.T.C.T.
COMMERCIAL CC-2
EMERGENCY, UTILITY,
AND DRAINAGE
EASEMENT
DOC.NO. D219154801
WATER EASEMENT
DOC.NO. D219154801
10' ELECTRIC ESMT.
DOC.NO. D220128638
D.R.T.C.T.
S 89°43'33" E 239.13'
BUILDING GROSS SQFT:
TOTAL APPROXIMATE LAND SIZE:
PARKING PROVIDED:
PARKING CALCULATIONS:
ZONED:CC-2
SITE DATA
86478 SQ.FT. / 1.985 ACRES
82 SPACES
5 SPACES PER 1,000 SQ.FT.79 SPACES
(1) 5,032 SQ.FT. + (1) 5,368 + (1) 5,340 SQ.FT.
BUILDING "A" GROSS AREA:5,032 S.F./5.81% OF TOTAL AREA
BUILDING "B" GROSS AREA:5,368 S.F./6.21% OF TOTAL AREA
BUILDING "C" GROSS AREA:5,340 S.F./6.18% OF TOTAL AREA
DRIVE LANE, PARKING AND FLATWORK AREA:48,915 S.F./56.56% OF TOTAL
AREA
OPEN SPACE:21,823 S.F./25.24% OF TOTAL
AREA
PROPOSED LOT "A" SIZE:28,884 SQ.FT. / 0.663 ACRES
PROPOSED USE:OFFICE
PROPOSED LOT "C" SIZE:32,712 SQ.FT. / 0.751 ACRES
PROPOSED LOT "B" SIZE:24,853 SQ.FT. / 0.571 ACRES
N 1 SITE PLAN
A0.1TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKVICINITY MAP
SITE LOCATION
NOTE:
ZONING EXHIBIT FOR ZONING CHANGE
REQUEST FROM CURRENT PD ZONING
ORDINANCE O-18-2065 TO AMENDED PD
N 03°16'15" E 100.24'N 05°30'54" W 45.28'S 88°08'58" W 255.79'S 03°03'53" E 344.82'N 00°44'00" W 200.00'N 04°44'15"W 8.63'PRECINCT LINE ROAD(R.O.W. VARIES)LOT 3, BLOCK 2
LAVACA TRAIL ADDITION
DOC.NO. D211238019
COMMERCIAL CC-2
LOT 4, BLOCK 2
LAVACA TRAIL ADDITION
DOC.NO. D217053885
D.R.T.C.T.
COMMERCIAL PUD-C
LOT 1, BLOCK 1
PRECINCT LINE RETAIL ADDITION
DOC.NO. D219154801
P.R.T.C.T.
COMMERCIAL CC-2
EMERGENCY, UTILITY,
AND DRAINAGE
EASEMENT
DOC.NO. D219154801
WATER EASEMENT
DOC.NO. D219154801
10' ELECTRIC ESMT.
DOC.NO. D220128638
D.R.T.C.T.
S 89°43'33" E 239.13'
N 1 EXISTING TREE PLAN
A0.2TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARK
1 BUILDING A - WEST ELEVATION
A2.0TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING A2 BUILDING A - SOUTH ELEVATION
1 BUILDING A - EAST ELEVATION
A2.1TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING A2 BUILDING A - NORTH ELEVATION
1 BUILDING A - SOUTHWEST PERSPECTIVE
A2.2TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING A2 BUILDING A - NORTHEAST PERSPECTIVE
1 BUILDING B - WEST ELEVATION
A3.0TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING B2 BUILDING B - SOUTH ELEVATION
1 BUILDING B - EAST ELEVATION
A3.1TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING B2 BUILDING B - NORTH ELEVATION
1 BUILDING B - SOUTHWEST PERSPECTIVE
A3.2TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING B2 BUILDING B - NORTHEAST PERSPECTIVE
1 BUILDING C - WEST ELEVATION
A4.0TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING C2 BUILDING C - NORTH ELEVATION
1 BUILDING C - EAST ELEVATION
A4.1TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING C2 BUILDING C - SOUTH ELEVATION
1 BUILDING C - NORTHEAST PERSPECTIVE
A4.2TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPROFESSIONAL OFFICE PARKBUILDING C2 BUILDING C - SOUTHWEST PERSPECTIVE
SITE AND DRIVE THRU PHOTOMETRIC PLAN
Scale: 1/16" = 1'-0"
1 4055 International Plaza Suite 100Fort Worth, Texas 76109(817)737-9922www.Franzarchitects.com796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
CERTIFICATE OF AUTHORITY NO. F-20080 TBD PRECINCT LN RDCOLLEYVILLE, TEXAS 76034PRELIMINARYNOT TO BE USEDFORREGULATORYAPPROVAL,PERMITTING ORCONSTRUCTION7608 Benbrook ParkwayBenbrook, Texas 76126(817)737-9922www.Franzarchitects.comPROFESSIONAL OFFICE PARKPHOTOMETRIC NOTES
POLE MOUNTING NOTES
PH-1.0
ORDINANCE 0-18-2065
AMENDING THE ZONING ORDINANCE AND THE OFFICIAL ZONING
MAP OF THE CITY OF COLLEYVILLE, TEXAS, BY CHANGING THE
ZONING ON 6.378 ACRES ON TRACT 1, ABSTRACT 1154, IN THE R H
MCEWING SURVEY, LOCATED AT 8060 PRECINCT LINE ROAD FROM
THE R-40 SINGLE FAMILY RESIDENTIAL DISTRICT TO THE PUD-C
PLANNED UNIT DEVELOPMENT — COMMERCIAL ZONING DISTRICT;
PROVIDING A PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO
THOUSAND DOLLARS ($2,000.00) AND PROVIDING AN EFFECTIVE
DATE
WHEREAS, the City of Colleyville has received an application for a rezoning
under Case No. ZC18-028; and
WHEREAS, the City of Colleyville deems it necessary, for the purpose of
promoting the health, safety, morals, or general welfare of the
City to enact a new zoning ordinance; and
WHEREAS, the City Council has appointed a Planning and Zoning
Commission to recommend the boundaries of the various
original zoning districts and appropriate regulations be
enforced therein and to recommend a new zoning ordinance;
and
WHEREAS, the Planning and Zoning Commission has divided the City into
districts and has prepared regulations pertaining to such
districts in accordance with a comprehensive plan designed to
lessen congestion in the streets; to secure safety from fire,
panic, and other dangers; to promote health, general welfare;
to provide adequate light and air; to prevent the overcrowding
of land; to avoid undue concentration of population; to
facilitate the adequate provision of transportation, water,
sewerage, schools, parks and other public requirements; and
WHEREAS, the Planning and Zoning Commission, has given reasonable
consideration, among other things, to the character of the
districts and their peculiar suitability for particular uses, with a
view to conserving the value of buildings and encouraging the
most appropriate use of land throughout the City; and
WHEREAS, the Planning and Zoning Commission of the City of Colleyville
and the City of Colleyville City Council, in compliance with the
Charter of the City of Colleyville, and State Law with reference
Ordinance 0-18-2065
Page 2of7
to changes to zoning classifications under the Zoning
Ordinance Regulations and Zoning Map, having given the
requisite notices by publication and otherwise, and after
holding due hearings and affording a full and fair hearing to all
the property owners generally, and to the persons interested
and situated in the affected area and in the vicinity thereof, the
governing body of the City of Colleyville is of the opinion that
said change in zoning should be made.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE
CITY OF COLLEYVILLE, TEXAS:
Sec. 1. THAT all the foregoing premises and findings are found to be
true and correct and are incorporated into the body of this
ordinance as if copied in their entirety.
Sec. 2. THAT the Comprehensive Zoning Ordinance of the City of
Colleyville, Texas, be, and the same is hereby amended by
changing the zoning on 6.378 acres on Tract 1, Abstract 1154,
in the R H McEwing Survey, located at 8060 Precinct Line Road
from the R-40 Single Family Residential zoning district to the
PUD-C Planned Unit Development - Commercial zoning district,
as depicted in the attached Exhibit "A" and Exhibit "C", and as
described in Exhibit "B".
Sec. 3. THAT the Official Zoning Map of the City of Colleyville be
amended to incorporate the zoning change approved herein.
Sec. 4. THAT the above described tract of land shall be subject to the
following conditions:
1. GENERAL
a. The purpose of this PUD-C is to allow for a self -storage
facility totaling approximately 87,375 square feet and to
provide development regulations for the future
development of three (3) retail/restaurant lots on Tract 2.
b. This development shall be generally consistent with the
Statement of Planning Objectives, Exhibit "B".
c. The proposed development is subject to CC-2 Shopping
Center zoning district and all the associated regulations
Ordinance 0-18-2065
Page 3 of 7
contained in the Land Development Code, except as
amended by this Ordinance.
2. DEVELOPMENT PLAN
a. The development shall be generally consistent with the
conceptual site plan and landscaping plan, Exhibit "C", and
the Site Plan and Building Elevations, Exhibit "C".
b. The development of Tract 2 shall be generally consistent
with the requirements of CC-2 Shopping Center zoning
district and all the associated regulations contained in the
Land Development Code, except as amended by this
Ordinance.
3. PERMITTED USES
a. Uses shall be those allowed in the CC-2 Shopping Center
zoning district.
b. The self -storage use as depicted in the attached exhibits
shall be a permitted use on Tract 1.
c. There shall be no outside storage allowed per this PUD to
include RV's, boats, materials, etc.
d. No commercial truck rentals on Tract 1 shall be allowed per
this PUD.
4. Lot Width
a. The minimum lot width allowed for Tract 1 shall be ±38 feet
at the property line.
5. BUILDING DESIGN
a. The storage facility on Tract 1 shall be generally consistent
with the building elevations and specified material depicted
in Exhibit "C".
Ordinance 0-18-2065
Page 4 of 7
b. Development on Tract 2 shall be generally consistent with
the requirements of the Land Development Code of the City
of Colleyville and the following design standards:
At least fifty percent (50) of the exterior wall surface
area shall be natural stone.
6. FENCING AND BUFFER YARDS
a. The buffer yard along the rear (east) property line shall be
a minimum of twenty-five feet.
b. On Tract 1, in lieu of an eight (8) foot masonry wall along
the east and south property lines adjacent to residential
zoning, the rear of the buildings and connecting eight (8)
foot masonry walls shall be permitted per the fence exhibit,
Exhibit "D".
7. Tree Preservation Standards
a. On Tract 1, minimum tree preservation standards will not
be met per this PUD.
b. Tree Preservation for Tract 2 shall be reviewed per Chapter
5 of the Land Development Code prior to development of
this tract. This conceptual site plan and associated civil
plans are not an approval of the layout as it pertains to
tree preservation on Tract 2.
8. LANDSCAPING
a. Tract 1: The requirement for fifty (50) percent of the
required landscaping to be located in the street yard(s) as
described in chapter 4.6 of the Land Development Code
for the City of Colleyville shall be waived for Tract 1. On
Tract 1, the landscape area shall be provided as
generally depicted in Exhibit "D".
b. Tract 2: Landscaping on Tract 2 shall conform to the CC-
2 Shopping Center zoning district and all the associated
regulations contained in the Land Development Code,
except as amended as follows:
Ordinance 0-18-2065
Page 5 of 7
There shall be a minimum twenty (20) foot wide
green belt of "live plant material of the evergreen
variety" along Precinct Line Road, exclusive of
access drives. This area may be planted with trees
shrubs required at the front of the site. Landscape
planting shall not be erected or installed in such a
manner as to interfere with traffic view or impose a
safety hazard. When Tract 1 develops, full
landscaping along the north one -hundred feet
100') of Precinct Line Road shall be installed.
ii. In addition to the requirements of locating 50% of
required landscaping in the street yard(s) as
described in Section 4.6 of the Land Development
Code for the City of Colleyville, developments on
Tract 2 shall be required to provide landscaped
areas immediately adjacent to each building equal to
ten (10) percent of the footprint area of the
building, with fifty (50) percent of that amount
being located in the street yard.
iii. Parking lots shall contain a minimum of one hundred
forty (140) square feet of landscaped island per each
nine (9) contiguous parking spaces required. This
landscape island is to include one (1) three (3) inch
caliper tree.
9. PARKING
a. A total of nine (9) parking spaces shall be required for the
storage facility on Tract 1.
b. Parking requirements for Tract 2 shall conform to the CC-
2 Shopping Center zoning district and all the associated
regulations contained in the Land Development Code.
c. No commercial truck rentals on Tract 1 shall be allowed
per this PUD.
d. Any vehicle associated with the operation of the self -
storage use on Tract 1 shall be parked/stored interior of
Ordinance 0-18-2065
Page 6of7
the development and shall not be utilized for any additional
advertising.
10. MONUMENT SIGN
a. All monument signs will conform to Exhibit "C" except for
the copy on the face of the sign which will be customized
for each user on Tract 2. The face of all signs will be the
same material and color or anodized aluminum, and sign
copy will be uniformly white Lexan.
11. OTHER
a. The applicant shall obtain an agreement with the adjacent
property owner to the east for off -site drainage
improvements to handle the discharge from the site.
Sec. 5. THAT the above described tract of land shall be used only in
the manner and for the purposes provided by the
Comprehensive Zoning Ordinance of the City of Colleyville as
heretofore amended, and as amended herein.
Sec. 6. THAT any person, firm or corporation violating any of the
provisions or terms of this ordinance shall be subject to the
same penalty as provided for in the Comprehensive Zoning
Ordinance of the City of Colleyville, and upon conviction shall
be punishable by a fine not to exceed the sum of Two Thousand
Dollars ($2,000.00) for each offense.
Sec. 7. THAT if any section, paragraph, subdivision, clause, phrase or
provision of this ordinance shall be judged invalid or
unconstitutional, the same shall not affect the validity of this
ordinance as a whole or any portion thereof other than that
portion so decided to be invalid or unconstitutional.
Sec. 8. THAT in addition to and accumulative of all other penalties, the
City shall have the right to seek injunctive relief for any and all
violations of this ordinance.
Sec. 9. THAT it has been found that there has been a change in
conditions in the above described property, it is now necessary
that it be given the above zoning classification in order to
permit its proper development and in order to protect the public
Ordinance 0-18-2065
Page 7 of 7
interest, comfort and general welfare, and requires that this
ordinance shall take effect immediately from and after its
passage.
AND IT IS SO ORDERED.
The first reading and public hearing being conducted on the 5th day of
November 2018.
The second reading and public hearing being conducted on the 20th day of
November 2018.
PASSED AND APPROVED by the City Council of the City of Colleyville, Texas,
on this the 20th day of November 2018.
Mayor Richard Newton Aye Mayor Pro Tern Bobby Lindamood Aye
Place 1, Tammy Nakamura Aye Place 3, Kathy Wheat Aye
Place 4, George Dodson Aye Place 5, Chuck Kelley Aye
Place 6, Callie Rigney Aye
ATTEST:
Christine Loven, TRMC
City Secretary
APPROVED AS TO
Atto rn ey
CITY OF COLLEYVILLE
I
Richard Newton
Mayor
Exhibit "'A" - Location and Zoning Map
COLLEYVILLE
1
11TExA6
DISCLAIMER:
This map and Informallon contained In It were
developed exclusively for use by the City of Colleyvllle.
Any use or reliance on this map by anyone else is
at that partys risk and without liability to the
City of Colleyville, Its officials or employees for any
discrepancies, errors, or variances which may ebsl.
8096
8100
8098 U®-C8092b
8090 8086
8080 8078
1
8074
102
8060 1 R-40
5920 IW
8050 5916
5912 C3
5908 Z
PU®'C 5904 it
5900 uJ
5644
5840
Me
5832
8000
5828
5824
5820
ZC18-028
8060 Precinct Line Road
6217 6206 6209
6213
O— g10
6209 6204
6205
6216 6213 812
H
6212 6209 6200
C
6208 6205 6116
6204 6201 6312
1013
6200 C LLV
6112 6113 6108
6108 6109 6104
6104
6105 6100
6100 6101 913
6032
5917
931 5912 5913D
5927
5922 5923 5908 5909
5800
OSubject Property
Properties Outside the City Limit
5918 5919
5914 W 5915 f
5910 Z 5911 5904 5905
5900 5901
5812
5813
5808
5809
5804 5805
Exhibit "B" - Statement of Planning Objectives
Statement of Planning Objectives
Advantage Storage
U1is 1102600EldoradoKineyTTexas aP`
Poe
972-547-0236
rjones@AdvantageStorage.nel STORAGE
7 September 2018
Mr. Ben Bryner, AICP
Director of Community Development
City of Colleyville
100 Main Street
Colleyville, Texas 76034
Re: Zoning Application
Proposed Self Storage Development
8060 North Precinct Line Road
Dear Mr. Bryner,
Please accept this letter in fulfilment of the zoning application provision for Statement of Planning Objectives,
Development Schedule, Proposed Ownership and Economic Information.
STATEMENT OF PLANNING OBJECTIVES:
The project consists of 6.378 acres located along North Precinct Line Road and is configured in two tracts.
Tract One contains 148,047 square feet (3,399 acres) and Tract Two contains 129,781 square feet (2.979
acres).
TRACT ONE:
The planning objective for Tract One is to develop a high quality self -storage facility. Storage facilities have
changed significantly over the past 20 years reflecting the evolution of the asset type from a low -quality light
industrial use to very high -quality retail service business. Whereas many early self -storage customers used
storage for short term, transitory reasons, the majority of contemporary storage customers secure storage
space for ongoing, space making reasons. These customers as well as others desire well located facilities
near where they work and live. Storage use is much higher per capita today than twenty years ago.
Storage development has changed to meet this market demand by providing higher quality facilities with
architecture compatible with the high -end retail locations in which they reside. Advantage has since 1996
been on the leading edge of this evolution, developing state-of-the-art facilities in very high profile, retail
locations.
The characteristics of the storage project are proposed to be:
The project will be situated on a 3.399 acre site with 38' of North Precinct Line Road frontage.
The project consists of two, two-story building and four single story buildings containing
approximately 87,225 gross SF configured to provide approximately 71,175 net rentable square feet
of storage consisting of approximately 625 individual storage units containing between 25 and 300
square feel.
Approximately 65% of the net rentable area will be climate controlled, appealing to the higher
household income in which the project resides.
Statement of Planning Objectives
The buildings fronting North Precinct Line Road will be two-story with maximum 29.5' height. This
allows the architecture of the building to replicate typical retail scale and incorporate interesting
architectural features.
All remaining buildings will be single story and will be oriented toward interior drives and will not
exceed 15' in height. Drive visibility from North Precinct Line Road will be minimal, and no door
openings will be oriented toward the perimeter of the project.
The rental office for the facility will be in the front building.
There will be no resident manager living on site
The project will include state-of-the-art security features including CCV cameras and tenant only
access via digital gate and building controls.
Project signage will be a combination of masonry monument sign and building signage conforming to
ordinance.
Landscaping will conform to or exceed ordinance requirements, and will be concentrated on the
project perimeters, most visible to the neighboring properties and the public.
Adequate space has been provided for engineered storm water detention and public utility
extensions as may be required.
TRACT TWO:
Tract Two contains 2.979 acres and will be zoned to provide for CC-2 Shopping Center uses. The tract is
approximately 250' deep which is ideal for small commercial and retail users. Although the actual users
have not yet been identified and therefore the precise building layout cannot be determined, the Conceptual
Development Plan depicts the likely configuration of three pad sites for retail and restaurant users. The
planning objective for Tract Two is to provide ideal lot depth to promote retail development and to provide an
access and utility plan to fully develop the tract. Additionally, the planning objective is to provide
construction standards to insure uniform, high quality development. Standards include the following:
Requirement for increased use of natural stone in building facades.
Enhanced requirement for landscape buffer along North Precinct Line Road.
Enhanced requirement for landscaping adjacent to retail buildings.
Enhanced requirement for landscaping in parking areas.
Enhanced requirement for uniform monument signs.
DEVELOPMENT SCHEDULE:
Platting and Site Plan Approval will commence immediately upon zoning approval.
Storage building permit will occur approximately 120 days following zoning approval.
Storage completion will occur approximately 14 months following zoning approval.
Markel demand will determine retail pad site development.
PROPOSED OWNERSHIP:
The storage project will be owned by a single asset limited liability company managed and controlled by
Advantage Self Storage Advisors, LLC, a Texas limited liability company owned by Rick Jones and Davis
Deadman.
ECONOMIC INFORMATION:
The prosed project will provide the following positive economic impact:
Property tax valuation will likely increase from the current level of $357,550 to approximately
7,500,000 upon completion of the facility. The increase in property value will provide
approximately $167,000 in additional tax revenue, most of which stays in the local community via
the city, school system and county.
Statement of Planning Objectives
The configuration of the proposed site is strategically conceived to promote retail and commercial
development on the pad -depth property remaining in front of the facility. The current 6-acre parcel
of which the storage facility is a portion is 545' deep. This is a size and depth that is awkward for
small to mid -size business who would typically locate on this mid -block commercial corridor and
does not promote development. The site plan provides remaining retail parcels with +/- 250' depth,
near ideal for small business and pad -site development. The property owner is understandably
very hesitant to sell front parcels currently because of the limited use and marketability of the back
portion of the land. With the storage development taking mainly the back portion, front parcels will
likely be quickly developed placing the entire six acres into economic production.
The storage facility will provide limited sales tax revenue via the sale of packing and moving
supplies.
The storage facility will have approximately 2-3 employees.
Kindest /Bards,
L
Rick Jones
Attachment: Draft PD Ordinance
Exhibit "C" -Site Plan and Building Elevations
Stl%3L 'ALNnOO LNVr vi '3aIVJ3noO do ul
yOSOS[m,y',yyewrll Q! sa£ SA31Nf15 NwM3N J'M ONV OxW,30n 'H 'tl M 53tlaY 8C'8F gA; q QQ
arz •va'wc..ax xomx A a@ °9
oxe,w g OtlON 3N0 1AMO3tld
LLd1uelsaOsnlnwn0 ! A Ntlld IONdOl3A30 ltlfiLd30N00 3
e
g $
41
3 ..;.;.;. ':.:..:..:.:.:....:.:'
it
q4q
i _z,_' _ •
gad= I t II _.e=
34k3 p9rg2 p(
a
me \q1'— — — — — — — — — — — Gc595 a
I;YI
Ir. ; _y„':• ::- ..........
Im
H.
o ff
E $
i
e __=
6=_e• Wizx aa.,raWWe====-. S yyl"'i6s'sliti:gl
rl lull „
Ig sx s g0 a 3,y$ yR.! .I o!!53Y ! g i
9s$spyppnf( es. a%yF isp I
4 36
iYXw d$Y 9YS`4 & 4r E '3fps 3a 4 ,
ta Y gg Sgay 5% li 1I i€1 1, n5 9e
g 9q ? gi-11ai3COY55gglipaIj 4 i 5 '$Ce pg'$ lE
l 1i! '1 51 !o y! 5 g @ ; ° e I WI ! @b g4e y$y7YaaA! $gypp pp ,gg yCqp p @@ 57§§gyp 1. 1. 41 Aj Y A ! S N Yi gi .I Ya11 Y4 50A Yx @ gg2gg
d
S a t o e(AAA 9111AAGI]OO-068101Se6elueAPy
OV9Z'60 Q3SIA39:suopeAGj0JGualxa
0111AA81100 - 068JOIS 0681UEAPV
S1d30NOO NOIIVA313 ONIOlIng 311S Otld
fill- z
M
HIM _ M
Exhibit "D" - Landscape Plan
NVId 3dVOSONVI ivnid3ONOO
gggggg
I'
n
ell- 9y e
s
t9 INH
Q!Q! )MI]li M/J IYd
HIM
HEm
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number 2c Agenda Date 11/25/2024 Number -
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a Special Use Permit to allow for a Daycare Center on a
portion of Lot 1, Block 1, Towne Center Animal Hospital, located at 4313 Colleyville
Boulevard, Case ZC24-028
Explanation
Isha Adhikari, the applicant, has submitted a request for a Special Use Permit for Lot 1,
Block 1, Towne Center Animal Hospital, approximately 4.747 acres, and zoned CC-2
Shopping Center. The request is to allow the construction of a new daycare center
known as Kiddie Academy.
Attachments
1. Aerial Map
2. Zoning Map
3. Site Plan
4. Statement of Planning Objectives
5. Building Elevations and Plans
6. Landscape Plan
7. Utility Plan
8. Tree Protection Plan
BROWN
TR
BRIDLEW
O
O
D
C
TCOLLEYVILLEBLVDBROOKHOLLOWD RMILL WOODDR
WATERFORD L N GREENMEADOWWBRIDLEWOOD N
G R E E N M E A D O W N
MILL VALLEY DR
STEEPLECHASE DRWELLINGTON DRPADDINGTON LNCOACHMAN LNFELPSDRK
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC24-028
4313 Colleyville Blvd
Aerial Map
BROWN
TR
BRIDLEW
O
O
D
C
TCOLLEYVILLEBLVDBROOKHOLLOWD RMILL WOODDR
WATERFORD L N GREENMEADOWWBRIDLEWOOD N
G R E E N M E A D O W N
MILL VALLEY DR
STEEPLECHASE DRWELLINGTON DRPADDINGTON LNCOACHMAN LNFELPSDRCC-1
RDCC-2
CC-1
R-MF
R-20
PUD-R
CC-2
PUD-R
PUD-R
R-40
CC-3
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC24-028
4313 Colleyville Blvd
Zoning Map
DD
SS///
///
///
///
///////////////
COLLEYVILLE BOULEVARD
(VARIABLE WIDTH PUBLIC RIGHT-OF-WAY)
ASPHALT ROAD
KIDDIE ACADEMY
(10,490 S.F.)
F.F.E=605.32
PLAY AREA
(11,983 S.F.)
PROP MASONRY DUMPSTER ENCLOSURE
WITH 8' HIGH WALLS AND METAL GATES.
REFER TO ARCHITECTURAL PLANS FOR
DETAILS.
ADA SIGN.
B.F.R.B.F.R.B.F.R.
6B.F.R.9'9'9'9'9'18'
18'
24'
F.A.U.E.
18'
24'
F.A.U.E.
18'9'6'10'18'5'
76.92'81.66'178.4'
42.16'140.33'75.74'EX.SHAREDACCESS30.36'11.38'
11.46'5'11.46'
11.38'6'12.1
4'15' B.S.15' B.S.10' B.S.
40' B.S.
20' LANDSCAPE
GREENBELT
10
11
924'FIRELANER30'R30'
R30'
R30'
R30'
R30'
R30'R30'
R5'
5'5'
10'5'5'5'5'5'6'
4' TALL WROUGHT
IRON INTERIOR
FENCE
5' TALL FENCE &
5' TALL AND 3.5' GATE
5' TALL WROUGHT
IRON PERIMETER
FENCE
4' TALL WROUGHT
IRON INTERIOR
FENCE
4' ALARMED PANIC
DEVICE GATE
4' ALARMED PANIC
DEVICE GATE
4' TALL WROUGHT IRON
INTERIOR FENCE
5' TALL WROUGHT
IRON PERIMETER
FENCE
5' TALL WROUGHT
IRON PERIMETER
FENCE 5'INFANT/TODDLER
PLAY EQUIPMENT
(196 SF TURF)
PRE-K PLAY
PLAY HOUSE
(25 SF TURF)
PRE-K PLAY
RIDING TRACK
(1000 SF HARD
SURFACE)
4' ALARMED PANIC
DEVICE GATE
4' TALL WROUGHT
IRON INTERIOR
FENCE
4' ALARMED PANIC
DEVICE GATE
5' TALL WROUGHT
IRON PERIMETER
FENCE
8
SOD
SOD
INFANT/
TODDLER
PLAY AREA
1,535 S.F.
PRE-K PLAY
AREA
3,389 S.F.
PROP. ILLUMINATED
MONUMENT SIGN
BY SEPARATE
PERMIT
CONNECT TO EX.
PAVEMENT
3.5' ACCESS GATE
3.5' ACCESS GATE
9'
10'
EX.
DRIVEWAY
ACCESS
EX. DRIVEWAYACCESSCONNECT TO EX.
PAVEMENT
5'14.84
'
SOD
SOD 7'5'APPROX. 86.95'PRE-K PLAY
EQUIPMENT (980
SF TURF)
PROP.
BOLLARDS
6" BOLLARDS @ 5'
C/C
3.5' ACCESS GATE
PROP 6' SIDEWALK CONNECTION
TO EX. 6' SIDEWALK.
4' ALARMED PANIC
DEVICE GATE
ADA RAMP.
5'
EX. FIRE HYDRANT
SITE LEGEND
CONCRETE CURB
SAW-CUT LINE
MONUMENT/PYLON SIGN
WHEEL STOPS
HANDICAP SIGN
HANDICAP LOGO
STRIPING
BOLLARD
FENCE
FIRE HYDRANT
RAMP
FIRE LANE
PARKING SPACES
TRAFFIC ARROW
DUMPSTER
X
SANITARY SEWER MANHOLE
SANITARY SEWER CLEANOUT
SANITARY SEWER DOUBLE CLEANOUT
SANITARY SEWER SAMPLE PORT
GREASE TRAP
DOMESTIC WATER METER
IRRIGATION METER
GAS METER
TRANSFORMER
LIGHT POLE
POWER POLE
SOD AREA
EXISTING LEGEND
BUILDING LINE
EASEMENT
BOUNDARY
CONCRETE
BRICK
STONE
WOOD DECK
GRAVEL
HIGHBANK LINE
PARKING STRIPE
BUILDING WALL
TILE
FIRE LANE STRIPE
PIPE RAIL FENCE
NO PARKING
CON. RET. WALL
HANDICAP SPACETELE. BOX
CABLE BOX
1/2" IR FOUND
1/2" IR SET
WATER METER
GAS METER
OHU OVERHEAD UTILITY LINE
BARBED WIRE FENCE
IRON FENCE
CHAINLINK FENCE
WOOD FENCE
X
A.C. PAD
UTILITY POLE
5/8" IR FOUND
ASPHALT
TRANS. BOX
60-D NAIL FOUND
ELECTRIC BOX
3/8" IR FOUND
SAN. SEW. CO.
PK NAIL SET
STONE RET. WALL
BRICK RET. WALL
IR. VALVE
STORM DRAIN MH.
SAN. SEW. MH.
IRRIGATION VALVE
WATER VALVE
FIRE HYDRANT
BRICK COLUMN
STONE COLUMN
GUY WIRE ANCHOR
1/2" IP FOUND
BOLLARD POST
LIGHT POLE
COVERED AREA
GAS MARKER1" IR FOUND
1" IP FOUND
POINT FOR CORNER
3/4" IP FOUND
CON. MONUMENT
X-FOUND
X-SET
SITE
VICINITY MAP
N.T.S.
N
SITE GENERAL NOTES
1.ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH THE
CITY OR LOCAL JURISDICTION STANDARDS.
2.THE LOCATION OF UNDERGROUND UTILITIES INDICATED ON THE
PLANS IS TAKEN FROM AS-BUILTS, UTILITY PLANS OR SURVEY. IT IS
THE CONTRACTOR'S RESPONSIBILITY TO MAKE ARRANGEMENTS
WITH THE OWNERS OF SUCH UNDERGROUND UTILITIES PRIOR TO
WORKING IN THE AREA TO CONFIRM THEIR EXACT LOCATION AND TO
DETERMINE WHETHER ANY ADDITIONAL UTILITIES OTHER THAN
THOSE SHOWN ON THE PLANS MAY BE PRESENT. THE CONTRACTOR
SHALL PRESERVE AND PROTECT ALL UNDERGROUND UTILITIES. IF
EXISTING UNDERGROUND UTILITIES ARE DAMAGED, THE
CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF REPAIRING
THE UTILITY.
3.WHERE EXISTING UTILITIES OR SERVICE LINES ARE CUT, BROKEN OR
DAMAGED, THE CONTRACTOR SHALL REPLACE OR REPAIR THE
UTILITIES OR SERVICE LINES WITH THE SAME TYPE OF ORIGINAL
MATERIAL AND CONSTRUCTION, OR BETTER, UNLESS OTHERWISE
SHOWN OR NOTED ON THE PLANS, AT HIS OWN COST AND EXPENSE.
THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER AT
ONCE OF ANY CONFLICTS WITH UTILITIES.
4.ALL EXCAVATIONS, TRENCHING AND SHORING OPERATIONS SHALL
COMPLY WITH THE REQUIREMENTS OF THE U. S. DEPARTMENT OF
LABOR, OSHA, CONSTRUCTION SAFETY AND HEALTH REGULATIONS
AND ANY AMENDMENTS THERETO.
5.THE CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED BY
CONSTRUCTION TO ORIGINAL CONDITION OR BETTER. RESTORED
AREAS INCLUDE, BUT ARE NOT LIMITED TO TRENCH BACKFILL, SIDE
SLOPES, FENCES, DRAINAGE DITCHES, DRIVEWAYS, PRIVATE YARDS
AND ROADWAYS.
6.ANY CHANGES NEEDED AFTER CONSTRUCTION PLANS HAVE BEEN
RELEASED, SHALL BE APPROVED BY THE CITY ENGINEER. THESE
CHANGES MUST BE RECEIVED IN WRITING.
7.THE CONTRACTOR SHALL PROVIDE "RED LINED" MARKED PRINTS TO
THE ENGINEER PRIOR TO FINAL INSPECTION INDICATING ALL
CONSTRUCTION WHICH DEVIATED FROM THE PLANS OR WAS
CONSTRUCTED IN ADDITION TO THAT INDICATED ON THE PLANS.
8.ALL CURB RADIUS TO BE 10' OR 2' UNLESS OTHERWISE NOTED ON
THE SITE PLAN.
TOTAL PARKING PROVIDED:
PROPOSED USE:
ZONING:
SITE ACREAGE:
BUILDING AREA:
HANDICAP PARKING PROVIDED:
IMPERVIOUS AREA:
BUILDING HEIGHT:
PERVIOUS/LANDSCAPE AREA:
REGULAR PARKING REQUIRED:
SITE DATA SUMMARY TABLE
NUMBER OF STORIES:
HANDICAP PARKING REQUIRED:
REGULAR PARKING PROVIDED:
BUILDING COVERAGE:
FLOOR AREA RATIO:
1.487 ACRES (64,773 S.F.)
CC-2
DAYCARE
10,490 S.F.
1
30'-0"
16.19%
0.16
1 SPACE PER 5 PUPILS
39 SPACES
42 SPACES
02 SPACES (1 VAN ACCESSIBLE)
02 SPACES (1 VAN ACCESSIBLE)
44 SPACES
49,696 S.F. (76.73%)
15,077 S.F. (23.27%)
NO. OF PUPILS 191
Know what's below.
Call before you dig.
TX. P.E. FIRM #11525
T: 469.331.8566 F: 469.213.7145 E: info@triangle-engr.com
W: triangle-engr.com O: 1782 W. McDermott Drive, Allen, TX 75013
Planning Civil Engineering Construction Management
KIDDIE ACADEMY
4401 COLLEYVILLE BLVD.
CITY OF COLLEYVILLE
TARRANT COUNTY, TEXAS 76034
TOWNE CENTER ANIMAL HOSPITAL, BLOCK 1, LOT 1
Scale: 1" = 'Feet
0
20
40
C-3.0
SUP SITE PLAN
PROJECT CONTACT LIST
ENGINEER
TRIANGLE ENGINEERING LLC
1782 W. McDERMOTT DRIVE
ALLEN, TEXAS 75013
CONTACT: KARTAVYA PATEL, P.E.
PHONE: 469-331-8566
OWNER/DEVELOPER
TRIANGLE DEVELOPMENT AND
MANAGEMENT SERVICES LLC
1782 W. MCDERMOTT DR.
ALLEN, TEXAS 75013
KEVIN PATEL
469-331-8566
SURVEYOR
TRAVERSE LAND SURVEYING LLC
14200 MIDWAY ROAD, SUITE 130
DALLAS, TEXAS 75224
CONTACT: GRAYSON CEBALLOS
PHONE: 469-784-9321
ARCHITECT
SOHO CONSTRUCTION
17774 PRESTON ROAD
DALLAS, TEXAS 75252
DAVID HOFF
EMAIL:david.hoff@soho-construction.com
City of Colleyville Community Development Department
100 Main Street
Colleyville, TX 76034
Subject: Kiddie Academy Daycare Development Proposal
The intent of this development proposal is to create a high-quality, purpose-built childcare facility
that will serve the local community and provide an exceptional early learning environment for young
children. The proposed Kiddie Academy daycare center will occupy a 1.487-acre parcel of land and
be designed to accommodate up to 191 children ranging from infants to school-age.
The key objectives guiding the planning and design of this facility are:
1. Providing a safe, nurturing, and stimulating learning environment for children:
o The building and outdoor spaces will be designed with age-appropriate play
equipment, educational resources, and activity zones to foster cognitive, social, and
physical development.
o Abundant natural light, ventilation, and connections to the outdoors will create a
bright, healthy, and engaging atmosphere.
o Secure access controls, age-segregated classrooms, and comprehensive
safety/security measures will ensure the wellbeing of all children.
2. Supporting working families with high-quality, accessible childcare services:
o Convenient location near major residential areas and transportation hubs will make
the daycare easily accessible for families.
o Flexible schedules, competitive tuition rates, and need-based financial assistance
will help accommodate the diverse childcare needs of the community.
3. Delivering a sustainable, community-integrated facility design:
o Generous outdoor play spaces, common gathering areas, and community event
hosting capabilities will transform the daycare into a neighborhood hub.
o Thoughtful landscaping and site planning will preserve and enhance natural
features, promoting biodiversity and stormwater management.
4. Establishing a trusted, high-quality childcare operator:
o Kiddie Academy is an established, nationally accredited childcare provider with a
track record of excellence.
o The center will be led by experienced, credentialed early childhood educators who
uphold rigorous teaching standards and foster a nurturing, stimulating learning
environment.
o Ongoing staƯ training, family engagement initiatives, and community outreach will
ensure the daycare remains responsive to local needs.
By considering the needs of young children, working families, and the broader community, this
Kiddie Academy daycare development will become a valuable asset that enriches the lives of local
residents for years to come.
Thank you for your consideration of our Special Use Permit request.
Kartavya Patel
Triangle Development and Management Services LLC
469-331-8566
COPYRIGHT C 2024 SOHO CONSTRUCTIONTHESE DRAWINGS, OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM, BY ANY METHOD, FOR ANY PURPOSE, WITHOUT PRIOR WRITTEN CONSENT FROM SOHO CONSTRUCTION.JOB#:ISSUE DATE:SCALE: DATE:APPROVED BY:24044KIDDIE ACADEMY AT COLLEYVILLE, TXwww.SOHO-CONSTRUCTION.com11/04/20241/16"=1-0"ELEVATIONS 01CSTANDARD NOTES
OLD TODDLERS18 CHILDREN540 REQ.. SQ.FT.590 ACTUAL SQ.FT.+52 YEAR OLDS22 CHILDREN660 REQ.. SQ.FT.661 ACTAUL SQ.FT.+52 YEAR OLDS22 CHILDREN660 REQ.. SQ.FT.663 ACTUAL SQ.FT.+53 YEAR OLDS30 CHILDREN900 REQ.. SQ.FT.904 ACTUAL SQ.FT.+53 YEAR OLDS30 CHILDREN900 REQ.. SQ.FT.902 ACTUAL SQ.FT.+54 YEAR OLDS18 CHILDREN540 REQ.. SQ.FT.547 ACTUAL SQ.FT.+54 YEAR OLDS18 CHILDREN540 REQ.. SQ.FT.545 ACTUAL SQ.FT.+5INFANT10 CHILDREN500 REQ. SQ.FT.505 ACTUAL SQ.FT.+5YOUNG TODDLERS13 CHILDREN390 REQ.. SQ.FT.440 ACTUAL SQ.FT.+5CAR SEAT STORAGEBUGGY
665 SF2 YEAR OLDS5505 SFINFANT1913 SF3 YEAR OLDS7913 SF3 YEAR OLDS8545 SF4 YEAR OLDS9395 SFYOUNGTODDLERS3545 SF4 YEAR OLDS10DIRECTOR'SOFFICEOWNER'SOFFICEVESTIBULECLOSETSERVERCLOSETRECEPTIONCOPIERLOBBYKITCHENJAN. CLOSET STAFFTOILET ROOM 9SPRINKLER
ELEC. CLOSET CAR SEAT STORAGE505 SFINFANTS2INFANT10 CHILDREN500 REQ. SQ.FT.505 ACTUAL SQ.FT.+5665 SF2 YEAR OLDS6BUGGY
545 SFOLD TODDLERS4LOUNGECOT CLOSET
COT CLOSET COT CLOSETCOT CLOSET
COT CLOSET
COT CLOSET
COT CLOSETGENERALSTORAGELOW HALF WALL & DOORLOW HALF WALL & DOORLOW HALF WALL & DOORLOW HALF WALL & DOORTOILET ROOMS ARE SET UPFOR 3 YRS & FUTURESCHOOL AGE TOILET ROOMSSIGNAGEZONOTACK BOARD4X3TACK BOARD4X3TACK BOARD4X3TACK BOARD4X3TACK BOARD4X3TACK BOARD4X3TACK BOARD4X3TACK BOARD5X3TACK BOARD4X3TACK BOARD4X3TACK BOARD3X3COMMUNITY CABINET
STAFFTOILET ROOM 1CHILDTOILET ROOM 2CHILDTOILET ROOM 3CHILDTOILET ROOM 4CHILDTOILET ROOM 5CHILDTOILET ROOM 6CHILDTOILET ROOM 7CHILDTOILET ROOM 8CHILDTOILET ROOM 10DWWIRE SHELFCAN RACKWORK TABLEMICROWAVEMICROWAVE SHELFRANGE/HOODFRIDGEFREEZERISLAND WORK TABLEDW3 BAY SINK 1 BAY SINK HANDSINK
COT CLOSET DRINKINGFOUNTAINDRINKINGFOUNTAINCOPYRIGHT C 2024 SOHO CONSTRUCTIONTHESE DRAWINGS, OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM, BY ANY METHOD, FOR ANY PURPOSE, WITHOUT PRIOR WRITTEN CONSENT FROM SOHO CONSTRUCTION.JOB#:ISSUE DATE:SCALE: DATE:APPROVED BY:24044KIDDIE ACADEMY AT COLLEYVILLE, TXwww.SOHO-CONSTRUCTION.com11/04/20243/16"=1-0"FLOOR PLAN 01
SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>
D
D
S
S
XXXXXXXXX X X
///
///
///
///
///////////////OHEOHEOHEOHEOHEOHEOHECOLLEYVILLE BOULEVARD
(VARIABLE WIDTH PUBLIC RIGHT-OF-WAY)
ASPHALT ROAD
SAN>SAN>KIDDIE ACADEMY
(10,490 S.F.)
F.F.E=605.32
PLAY AREA
(12,286 S.F.)
PROP MASONRY DUMPSTER ENCLOSURE
WITH 8' HIGH WALLS AND METAL GATES.
REFER TO ARCHITECTURAL PLANS FOR
DETAILS.
ADA SIGN.
B.F.R.B.F.R.B.F.R.
6B.F.R.15' B.S.15' B.S.10' B.S.
40' B.S.
20' LANDSCAPE
GREENBELT
10
11
9
4' TALL WROUGHT
IRON INTERIOR
FENCE
5' TALL FENCE &
5' TALL AND 3.5' GATE
5' TALL WROUGHT
IRON PERIMETER
FENCE
4' TALL WROUGHT
IRON INTERIOR
FENCE
4' ALARMED PANIC
DEVICE GATE
4' ALARMED PANIC
DEVICE GATE
4' TALL WROUGHT IRON
INTERIOR FENCE
5' TALL WROUGHT
IRON PERIMETER
FENCE
5' TALL WROUGHT
IRON PERIMETER
FENCE
INFANT/TODDLER
PLAY EQUIPMENT
(196 SF TURF)
PRE-K PLAY
PLAY HOUSE
(25 SF TURF)
PRE-K PLAY
RIDING TRACK
(1000 SF HARD
SURFACE)
4' ALARMED PANIC
DEVICE GATE
4' TALL WROUGHT
IRON INTERIOR
FENCE
4' ALARMED PANIC
DEVICE GATE
5' TALL WROUGHT
IRON PERIMETER
FENCE
8
SOD
SOD
INFANT/
TODDLER
PLAY AREA
1,535 S.F.
PRE-K PLAY
AREA
3,389 S.F.
PROP. ILLUMINATED
MONUMENT SIGN
BY SEPARATE
PERMIT
CONNECT TO EX.
PAVEMENT
3.5' ACCESS GATE
3.5' ACCESS GATE
CONNECT TO EX.
PAVEMENT
SOD
SOD
PRE-K PLAY
EQUIPMENT (980
SF TURF)
PROP.
BOLLARDS
6" BOLLARDS @ 5'
C/C
3.5' ACCESS GATE
PROP 6' SIDEWALK CONNECTION
TO EX. 6' SIDEWALK.
4' ALARMED PANIC
DEVICE GATE
ADA RAMP.
PROP. 5' CURB CUT
W/ROCK RIP RAP
PROP. 5' CURB CUT
W/ROCK RIP RAP
605
605605605605 605
605605 605604604604604
604
604
6046046046036036
0
3 603603
603
603
60360260160059960
1 601
604603
600
600
601
599
599
598
5
9
9
600
6
0
2
CE
1
SC
190
CE
1
CE
1
CE
1
LOR
14
CE
1
CE
1
CE
1
DWM
97
LO
4
ISSUE:
DATE:
SHEET NAME:
SHEET NUMBER:CHRIS TRON
Z
ANOSTA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT2204
11.07.2024
100 20 40
01 LANDSCAPE PLAN
SCALE 1"=20'-0"
11.07.2024
LANDSCAPE PLAN
L.2
LANDSCAPE ARCHITECT
STUDIO GREEN SPOT, INC.
1782 W. McDERMOTT DR.
ALLEN, TEXAS 75013
(469) 369-4448
CHRIS@STUDIOGREENSPOT.COM
BOTANICAL NAME
Ulmus crassifolia
Quercus virginiana
COMMON NAME
Cedar Elm
Live Oak
SIZE
4" cal.
4" cal.
PLANT MATERIAL SCHEDULE:
REMARKS
B&B, 12' ht., 4' spread min., 5' clear trunk
container, 13' ht., 4' spread min., 5' clear trunk
QTY
7
4
TREES
SHRUBS
GROUNDCOVERS
BOTANICAL NAME
Cynodon dactylon '419'
COMMON NAME
Seasonal Color
'419' Bermudagrass
SIZE
4" pots
REMARKS
selection by owner, 12" o.c.
Solid Sod refer to notes
TYPE
CE
LO
QTY
190
TYPE
SC
BOTANICAL NAME
Myrica cerifera
Loropetalum chinesis
COMMON NAME
Dwarf Wax Myrtle
Loropetalum
SIZE
24" ht. / 5 gal. min.
24" ht. / 5 gal. min.
REMARKS
conatiner, 24" ht., 20" spread. 24" o.c.
container, 24" ht., 24" spread, 30" o.c.
QTY
97
14
TYPE
DWM
LOR
NOTE: Plant list is an aid to bidders only. Contractor shall verify all quantities on plan. All heights and spreads are minimums. All plant material
shall meet or exceed remarks as indicated. All trees to have straight trunks and be matching within varieties.
FOR APPROVAL 11.07.2024
ALL LANDSCAPE WILL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM DESIGNED BY A STATE OF TEXAS
LICENSED IRRIGATOR TO THE STANDARDS OF THE CITY OF MCKINNEY AND TECQ. THE SYSTEM WILL INCLUDE AN
ET BASED CONTROLLER WITH A RAIN AND FREEZE SENSOR.
SOLID SOD NOTES
LANDSCAPE NOTES
1 FINE GRADE AREAS TO ACHIEVE FINAL CONTOURS INDICATED.
LEAVE AREAS TO RECEIVE TOPSOIL 3" BELOW FINAL DESIRED
GRADE IN PLANTING AREAS AND 1" BELOW FINAL GRADE IN TURF
AREAS.
2.ADJUST CONTOURS TO ACHIEVE POSITIVE DRAINAGE AWAY FROM
BUILDINGS. PROVIDE UNIFORM ROUNDING AT TOP AND BOTTOM
OF SLOPES AND OTHER BREAKS IN GRADE. CORRECT
IRREGULARITIES AND AREAS WHERE WATER MAY STAND.
3.ALL LAWN AREAS TO RECEIVE SOLID SOD SHALL BE LEFT IN A
MAXIMUM OF 1" BELOW FINAL FINISH GRADE. CONTRACTOR TO
COORDINATE OPERATIONS WITH ON-SITE CONSTRUCTION
MANAGER.
4.CONTRACTOR TO COORDINATE WITH ON-SITE CONSTRUCTION
MANAGER FOR AVAILABILITY OF EXISTING TOPSOIL.
5.PLANT SOD BY HAND TO COVER INDICATED AREA COMPLETELY.
INSURE EDGES OF SOD ARE TOUCHING. TOP DRESS JOINTS BY
HAND WITH TOPSOIL TO FILL VOIDS.
6.ROLL GRASS AREAS TO ACHIEVE A SMOOTH, EVEN SURFACE, FREE
FROM UNNATURAL UNDULATIONS.
7.WATER SOD THOROUGHLY AS SOD OPERATION PROGRESSES.
8.CONTRACTOR SHALL MAINTAIN ALL LAWN AREAS UNTIL FINAL
ACCEPTANCE. THIS SHALL INCLUDE, BUT NOT LIMITED TO:
MOWING, WATERING, WEEDING, CULTIVATING, CLEANING AND
REPLACING DEAD OR BARE AREAS TO KEEP PLANTS IN A
VIGOROUS, HEALTHY CONDITION.
9.CONTRACTOR SHALL GUARANTEE ESTABLISHMENT OF AN
ACCEPTABLE TURF AREA AND SHALL PROVIDE REPLACEMENT
FROM LOCAL SUPPLY IF NECESSARY.
10.IF INSTALLATION OCCURS BETWEEN SEPTEMBER 1 AND MARCH 1,
ALL SOD AREAS TO BE OVER-SEEDED WITH WINTER RYEGRASS, AT
A RATE OF (4) POUNDS PER ONE THOUSAND (1000) SQUARE FEET.
1.CONTRACTOR SHALL VERIFY ALL EXISTING AND PROPOSED SITE
ELEMENTS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES.
SURVEY DATA OF EXISTING CONDITIONS WAS SUPPLIED BY OTHERS.
2.CONTRACTOR SHALL LOCATE ALL EXISTING UNDERGROUND
UTILITIES AND NOTIFY ARCHITECT OF ANY CONFLICTS.
CONTRACTOR SHALL EXERCISE CAUTION WHEN WORKING IN THE
VICINITY OF UNDERGROUND UTILITIES.
3.CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED
LANDSCAPE AND IRRIGATION PERMITS.
4.CONTRACTOR TO PROVIDE A MINIMUM 2% SLOPE AWAY FROM ALL
STRUCTURES.
5.ALL PLANTING BEDS AND LAWN AREAS TO BE SEPARATED BY STEEL
EDGING. NO STEEL TO BE INSTALLED ADJACENT TO SIDEWALKS OR
CURBS.
6.ALL LANDSCAPE AREAS TO BE 100% IRRIGATED WITH AN
UNDERGROUND AUTOMATIC IRRIGATION SYSTEM AND SHALL
INCLUDE RAIN AND FREEZE SENSORS.
7.ALL LAWN AREAS TO BE SOLID SOD BERMUDAGRASS, UNLESS
OTHERWISE NOTED ON THE DRAWINGS.
1.FINE GRADE AREAS TO ACHIEVE FINAL CONTOURS INDICATED ON CIVIL
PLANS.
2.ADJUST CONTOURS TO ACHIEVE POSITIVE DRAINAGE AWAY FROM
BUILDINGS. PROVIDE UNIFORM ROUNDING AT TOP AND BOTTOM OF
SLOPES AND OTHER BREAKS IN GRADE. CORRECT IRREGULARITIES
AND AREAS WHERE WATER MAY STAND.
3.ALL LAWN AREAS TO RECEIVE SOLID SOD SHALL BE LEFT IN A MAXIMUM
OF 1" BELOW FINAL FINISH GRADE. CONTRACTOR TO COORDINATE
OPERATIONS WITH ON-SITE CONSTRUCTION MANAGER.
4.IMPORTED TOPSOIL SHALL BE NATURAL, FRIABLE SOIL FROM THE
REGION, KNOWN AS BOTTOM AND SOIL, FREE FROM LUMPS, CLAY,
TOXIC SUBSTANCES, ROOTS, DEBRIS, VEGETATION, STONES,
CONTAINING NO SALT AND BLACK TO BROWN IN COLOR.
5.ALL LAWN AREAS TO BE FINE GRADED, IRRIGATION TRENCHES
COMPLETELY SETTLED, AND FINISH GRADE APPROVED BY THE OWNER'S
CONSTRUCTION MANAGER OR ARCHITECT PRIOR TO INSTALLATION.
6.ALL ROCKS 3/4" DIAMETER AND LARGER, DIRT CLODS, STICKS,
CONCRETE SPOILS, ETC. SHALL BE REMOVED PRIOR TO PLACING
TOPSOIL AND ANY LAWN INSTALLATION
7.CONTRACTOR SHALL PROVIDE (1") ONE INCH OF IMPORTED TOPSOIL ON
ALL AREAS TO RECEIVE LAWN.
GENERAL LAWN NOTES
KIDDIE ACADEMYCOLLEYVILLE BLVD.COLLEYVILLE, TEXASLANDSCAPE TABULATIONS
LANDSCAPED AREA
Requirements: At least 20% of the site to be landscaped shall be landscape.
While 50% of the required landscaped area located in the street yard
Total Lot Area: 64,778 s.f.
Required Provided
Site:
12,956 s.f. (20%) 24,720 s.f. (38%)
Front Yard:
6,478 s.f. (50%) 7,043 s.f. (55%)
LANDSCAPE TREES/SHRUBS
Requirements: One (1) canopy tree per 40 L.F. of the street frontage. Along with
one (1) shrub per 5 L.F. of street frontage.
Colleyville Blvd.: 201 L.F.
Required Provided
(5) canopy trees (4) canopy trees + (2) existing trees to remain
(41) shrubs (99) shrubs
PARKING LOT LANDSCAPE
Requirement: (1) Tree per Island (One Island per 18 spots), 140 s.f. of landscape
per island.
Total Parking Lot Islands: 5 islands
Required Provided
(5) Trees, 4" cal. (7) Trees, 4" cal.
700 S.F. 1,530 S.F.
ISSUE:
DATE:
SHEET NAME:
SHEET NUMBER:CHRIS TRON
Z
ANOSTA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT2204
11.07.2024
11.07.2024
LANDSCAPE SPECIFICATIONS
L.3
6"
2X DIAMETER
OF ROOTBALL
01 TREE PLANTING DETAIL
NOT TO SCALE4'-5' MTG. HT.6"(3) METAL T-POST PAINTED
GREEN TRIANGULAR SPACING.
NOTE: LOCATE STAKES OUTSIDE
OF TREE WELL. POSITION STAKES
TO SECURE TREE AGAINST SEASONAL
PREVAILING WINDS.
NATIVE SOIL, REF. SPECIFICATIONS
6"
FINISH GRADE SCARIFY SIDES
CRUSHED ROCK
2" LAYER MULCH, REF. SPECIFICATIONS
REFERENCE PLAN FOR TREE TYPE
DO NOT CUT CENTRAL LEADER
2 STRANDS NO. 12 GAUGE
GALVANIZED WIRE, TWISTED
RUBBER HOSE
2" HIGH WATERING RING
4" DIA. PERFORATED
PVC PIPE W/ CAP
PAINTED BLACK ROOTBALL, DO NOT DISTURB. TOP
OF ROOTBALL TO BE SET 1" ABOVE
EXISTING GRADE. REMOVE TOP 1/3 BURLAP.
1/2" MINIMUM BETWEEN TOP OF MULCH
AND TOP OF CONCRETE
1/2" MAXIMUM
SIDEWALK
PREPARED SOIL MIX
PER SPECIFICATIONS
SHRUBS AND GROUNDCOVER
REFER TO PLANS FOR PLANT TYPES
MULCH PER SPECIFICATIONS
PREPARED SOIL MIX
PER SPECIFICATIONS
1/8" X 4" GREEN STEEL EDGING
WITH STAKES
03 SIDEWALK / MULCH DETAIL
NOT TO SCALE
04 STEEL EDGING DETAIL
NOT TO SCALE
no steel along sidewalks
NOTE: NO STEEL EDGING TO BE INSTALLED
ALONG SIDEWALKS
LAWN
SHRUBS AND GROUNDCOVER
REFER TO PLANS FOR PLANT TYPES
PREPARED SOIL MIX PER SPECS.
6" MIN. OF PREPARED SOIL MIX
TILLED INTO EXISTING SOIL TO
A DEPTH OF 6"
2" LAYER OF SPECIFIED BARK MULCH
ROOTBALL, DO NOT DISTURB
NOTE: POCKET PLANTING NOT
ALLOWED
FINISH GRADE
REF. PLAN FOR SHRUB TYPE
05 SHRUB PLANTING DETAIL
NOT TO SCALE
SPACING PER
PLANT LIST6"
NATIVE SOIL
PREPARE GROUNDCOVER
BED BY TILLING ENTIRE BED
AREA. PROVIDE SOIL MIX
AS DEFINED IN THE LANDSCAPE
SPECIFICATIONS
2" MULCH DOUBLE SHREDDED HARDWOOD
MULCH IN BED PRIOR TO
PLANTING GROUNDCOVER/ANNUALS.
12" MIN
EDGE OF BED
DD
D
A
A
PLANT ROW SPACING 'D' ROW SPACING 'A' PLANTS/10SF
8" O.C.
12" O.C.
15" O.C.
18" O.C.
6.9"
10.4"
13.0"
15.7"
26
12
7
5
A = ROW SPACING
B = ON CENTER SPACING
SPACE PLANTS IN A TRIANGULAR
PATTERNAS SHOWN, SPACED EQUALLY
FROM EACHOTHER AT SPACING
INDICATED ON PLANT LIST.
02 GROUNDCOVER PLANTING DETAIL
NOT TO SCALE
LANDSCAPE ARCHITECT
STUDIO GREEN SPOT, INC.
1782 W. McDERMOTT DR.
ALLEN, TEXAS 75013
(469) 369-4448
CHRIS@STUDIOGREENSPOT.COM
FOR APPROVAL 11.07.2024KIDDIE ACADEMYCOLLEYVILLE BLVD.COLLEYVILLE, TEXAS
W W W
WWWWWWWWWWWWWWWWW W W W W W W W W W W
SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>
DD
S
S
///
///
///
///
///////////////OHEOHEOHEOHEOHEOHEOHECOLLEYVILLE BOULEVARD
(VARIABLE WIDTH PUBLIC RIGHT-OF-WAY)
ASPHALT ROAD
KIDDIE ACADEMY
(10,490 S.F.)
F.F.E=605.32
PLAY AREA
(11,983 S.F.)15' B.S.15' B.S.10' B.S.
40' B.S.
20' LANDSCAPE
GREENBELT
E-1
INSTALL:
1 - 8" X 1" TAPPING SADDLE
1- IRRIGATION METER
1-RPZ BACKFLOW PREVENTER
±12 LF OF 1" IRRIGATION WATER LINE
1-1" PLUG.
CONNECT TO EX. SANITARY SEWER
MANHOLE . INSTALL DROP CONNECTION
PER CITY STANDARD.
EX. 12" PVC FL(OUT)=584.39
EX. 12" PVC FL(IN)=584.52
PROP. 6" PVC FL(IN)=594.52
PROP. RIM=598.50
SEWER LINE POINT OF
ENTRY
±102 LF OF 6" SANITARY
SEWER LINE
INSTALL:
1 - 8" X 2" TAPPING SADDLE
1- DOMESTIC WATER METER
1-RPZ BACKFLOW PREVENTER
±125 LF OF 2" DOMESTIC WATER LINE
WATER LIE POINT OF
ENTRY
PROP. GREASE TRAP
6" FL (OUT)=599.31
6" FL (IN)=599.57
RIM=603.91
PROP. SAMPLE WELL
6" FL(IN/OUT)=598.95
RIM=603.56
±74 LF OF 6" SANITARY
SEWER LINE
T-1
G-1
DBL CLEANOUT
6" FL=601.32
PROP. 6"X6" WYE
6" FL =596.57
PROP. CLEANOUT
6" FL=597.08
EX. FIRE HYDRANT
INSTALL:
1 - 8" X 6" TEE
1- 6" VALVE
±129 LF OF 6" FIRE LINE TO BUILDING
INSTALL:
1 - 8" X 6" TEE
1- 6" VALVE
1-CITY STD FIRE HYDRANT ASSEMBLY
PROP. FDC
UTILITY LEGEND
GAS LINE
UNDERGROUND TELEPHONE LINE
SANITARY SEWER LINE
WATER MAIN
STORM LINE
STORM SEWER MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER CLEANOUT
SANITARY SEWER DOUBLE CLEANOUT
SANITARY SEWER SAMPLE PORT
UNDERGROUND ELECTRIC LINE
GREASE TRAP
FIRE HYDRANT
DOMESTIC WATER METER
IRRIGATION METER
GAS METER
TRANSFORMER
DOMESTIC WATER LINE
STORM SEWER CLEANOUT
FIRE DEPARTMENT CONNECTION-FDC
LIGHT POLE
POWER POLE
EXISTING LEGEND
BUILDING LINE
EASEMENT
BOUNDARY
CONCRETE
BRICK
STONE
WOOD DECK
GRAVEL
HIGHBANK LINE
PARKING STRIPE
BUILDING WALL
TILE
FIRE LANE STRIPE
PIPE RAIL FENCE
NO PARKING
CON. RET. WALL
HANDICAP SPACETELE. BOX
CABLE BOX
1/2" IR FOUND
1/2" IR SET
WATER METER
GAS METER
OHU OVERHEAD UTILITY LINE
BARBED WIRE FENCE
IRON FENCE
CHAINLINK FENCE
WOOD FENCE
X
A.C. PAD
UTILITY POLE
5/8" IR FOUND
ASPHALT
TRANS. BOX
60-D NAIL FOUND
ELECTRIC BOX
3/8" IR FOUND
SAN. SEW. CO.
PK NAIL SET
STONE RET. WALL
BRICK RET. WALL
IR. VALVE
STORM DRAIN MH.
SAN. SEW. MH.
IRRIGATION VALVE
WATER VALVE
FIRE HYDRANT
BRICK COLUMN
STONE COLUMN
GUY WIRE ANCHOR
1/2" IP FOUND
BOLLARD POST
LIGHT POLE
COVERED AREA
GAS MARKER1" IR FOUND
1" IP FOUND
POINT FOR CORNER
3/4" IP FOUND
CON. MONUMENT
X-FOUND
X-SET
SITE
VICINITY MAP
N.T.S.
N
UTILITY GENERAL NOTES
1.ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH THE
CITY/UTILITY COMPANY STANDARDS.
2.FIELD VERIFY LOCATION OF EXISTING WATER MAIN , SEWER MAIN, GAS,
TELEPHONE AND ELECTRICAL LINE. POT HOLE RECOMMENDED PRIOR TO
CONSTRUCTION BEGIN. CONTRACTOR SHALL BE RESPONSIBLE TO
COORDINATE WITH UTILITY SERVICE PROVIDERS.
3.THE LOCATION OF UNDERGROUND UTILITIES INDICATED ON THE PLANS IS
TAKEN FROM AS-BUILTS, UTILITY PLANS OR SURVEY. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO MAKE ARRANGEMENTS WITH THE
OWNERS OF SUCH UNDERGROUND UTILITIES PRIOR TO WORKING IN THE
AREA TO CONFIRM THEIR EXACT LOCATION AND TO DETERMINE WHETHER
ANY ADDITIONAL UTILITIES OTHER THAN THOSE SHOWN ON THE PLANS MAY
BE PRESENT. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL
UNDERGROUND UTILITIES. IF EXISTING UNDERGROUND UTILITIES ARE
DAMAGED, THE CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF
REPAIRING THE UTILITY.
4.WHERE EXISTING UTILITIES OR SERVICE LINES ARE CUT, BROKEN OR
DAMAGED, THE CONTRACTOR SHALL REPLACE OR REPAIR THE UTILITIES OR
SERVICE LINES WITH THE SAME TYPE OF ORIGINAL MATERIAL AND
CONSTRUCTION, OR BETTER, UNLESS OTHERWISE SHOWN OR NOTED ON
THE PLANS, AT HIS OWN COST AND EXPENSE. THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE ENGINEER AT ONCE OF ANY CONFLICTS WITH
UTILITIES.
5.ALL EXCAVATIONS, TRENCHING AND SHORING OPERATIONS SHALL COMPLY
WITH THE REQUIREMENTS OF THE U. S. DEPARTMENT OF LABOR, OSHA,
CONSTRUCTION SAFETY AND HEALTH REGULATIONS AND ANY AMENDMENTS
THERETO.
6.THE CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED BY
CONSTRUCTION TO ORIGINAL CONDITION OR BETTER. RESTORED AREAS
INCLUDE, BUT ARE NOT LIMITED TO TRENCH BACKFILL, SIDE SLOPES,
FENCES, CULVERT PIPES, DRAINAGE DITCHES, DRIVEWAYS, PRIVATE YARDS
AND ROADWAYS.
7.ANY CHANGES NEEDED AFTER CONSTRUCTION PLANS HAVE BEEN
RELEASED, SHALL BE APPROVED BY THE CITY ENGINEER. THESE CHANGES
MUST BE RECEIVED IN WRITING.
8.THE CONTRACTOR SHALL PROVIDE "RED LINED" MARKED PRINTS TO THE
ENGINEER PRIOR TO FINAL INSPECTION INDICATING ALL CONSTRUCTION
WHICH DEVIATED FROM THE PLANS OR WAS CONSTRUCTED IN ADDITION TO
THAT INDICATED ON THE PLANS.
ID
D
I
WATER METER & SANITARY SEWER SCHEDULE
TYPE SIZE NO.
DOMESTIC 2"1
IRRIGATION 1"1
SANITARY SEWER 6"
Know what's below.
Call before you dig.
TX. P.E. FIRM #11525
T: 469.331.8566 F: 469.213.7145 E: info@triangle-engr.com
W: triangle-engr.com O: 1782 W. McDermott Drive, Allen, TX 75013
Planning Civil Engineering Construction Management
KIDDIE ACADEMY
4401 COLLEYVILLE BLVD.
CITY OF COLLEYVILLE
TARRANT COUNTY, TEXAS 76034
TOWNE CENTER ANIMAL HOSPITAL, BLOCK 1, LOT 1
Scale: 1" = 'Feet
0
20
40
PRELIMINARY UTILITY PLAN
C-9.0
PROPOSED DRY UTILITY CALLOUTS
LABEL CALLOUT
E1
POLE MOUNTED TRANSFORMER & PRIMARY ELECTRIC SERVICE BY
SERVICE PROVIDER. GC TO INSTALL (1)-4" CONDUIT AND SECONDARY
WIRE FROM TRANSFORMER TO THE BUILDING. GC TO COORDINATE
WITH LOCAL SERVICE PROVIDER FOR EXACT LOCATION.
T1
PRIMARY UNDERGROUND TELEPHONE SERVICE BY SERVICE
PROVIDER. GC TO INSTALL 2-4" CONDUITS FROM BUILDING TO
PROPERTY LINE & COORDINATE WITH LOCAL TELEPHONE SERVICE
PROVIDER FOR EXACT LOCATION.
G1
PROP. PRIMARY GAS SERVICE LINE EXTENSION TO GAS METER BY
FRANCHISE UTILITY COMPANY. GC TO COORDINATE WITH SERVICE
PROVIDER FOR PRIMARY GAS SERVICE LINE & GAS METER
LOCATION.GC TO REFER TO MEP PLANS FOR GAS LINE SIZE.
SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>SAN>
D
D
S
S
XXXXXXXXX X X
///
///
///
///
///////////////OHEOHEOHEOHEOHEOHEOHECOLLEYVILLE BOULEVARD
(VARIABLE WIDTH PUBLIC RIGHT-OF-WAY)
ASPHALT ROAD
SAN>SAN>KIDDIE ACADEMY
(10,490 S.F.)
F.F.E=605.32
PLAY AREA
(12,286 S.F.)
PROP MASONRY DUMPSTER ENCLOSURE
WITH 8' HIGH WALLS AND METAL GATES.
REFER TO ARCHITECTURAL PLANS FOR
DETAILS.
ADA SIGN.
B.F.R.B.F.R.B.F.R.
6B.F.R.15' B.S.15' B.S.10' B.S.
40' B.S.
20' LANDSCAPE
GREENBELT
10
11
9
4' TALL WROUGHT
IRON INTERIOR
FENCE
5' TALL FENCE &
5' TALL AND 3.5' GATE
5' TALL WROUGHT
IRON PERIMETER
FENCE
4' TALL WROUGHT
IRON INTERIOR
FENCE
4' ALARMED PANIC
DEVICE GATE
4' ALARMED PANIC
DEVICE GATE
4' TALL WROUGHT IRON
INTERIOR FENCE
5' TALL WROUGHT
IRON PERIMETER
FENCE
5' TALL WROUGHT
IRON PERIMETER
FENCE
INFANT/TODDLER
PLAY EQUIPMENT
(196 SF TURF)
PRE-K PLAY
PLAY HOUSE
(25 SF TURF)
PRE-K PLAY
RIDING TRACK
(1000 SF HARD
SURFACE)
4' ALARMED PANIC
DEVICE GATE
4' TALL WROUGHT
IRON INTERIOR
FENCE
4' ALARMED PANIC
DEVICE GATE
5' TALL WROUGHT
IRON PERIMETER
FENCE
8
SOD
SOD
INFANT/
TODDLER
PLAY AREA
1,535 S.F.
PRE-K PLAY
AREA
3,389 S.F.
PROP. ILLUMINATED
MONUMENT SIGN
BY SEPARATE
PERMIT
CONNECT TO EX.
PAVEMENT
3.5' ACCESS GATE
3.5' ACCESS GATE
CONNECT TO EX.
PAVEMENT
SOD
SOD
PRE-K PLAY
EQUIPMENT (980
SF TURF)
PROP.
BOLLARDS
6" BOLLARDS @ 5'
C/C
3.5' ACCESS GATE
PROP 6' SIDEWALK CONNECTION
TO EX. 6' SIDEWALK.
4' ALARMED PANIC
DEVICE GATE
ADA RAMP.
PROP. 5' CURB CUT
W/ROCK RIP RAP
PROP. 5' CURB CUT
W/ROCK RIP RAP
605
605605605605 605
605605 605604604604604
604
604
6046046046036036
0
3 603603
603
603
60360260160059960
1 601
604603
600
600
601
599
599
598
5
9
9
600
6
0
2
3684
3685
3686 3687
ISSUE:
DATE:
SHEET NAME:
SHEET NUMBER:CHRIS TRON
Z
ANOSTA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT2204
11.07.2024
100 20 40
01 TREE PRESERVATION PLAN
SCALE 1"=20'-0"
11.07.2024
TREE PRESERVATION PLAN
L.1
LANDSCAPE ARCHITECT
STUDIO GREEN SPOT, INC.
1782 W. McDERMOTT DR.
ALLEN, TEXAS 75013
(469) 369-4448
CHRIS@STUDIOGREENSPOT.COM
FOR APPROVAL 11.07.2024
1.Existing trees to remain shall be protected during construction from tree
structure damage and compaction of soil under and around dripline (canopy)
of tree.
2.If any root structure is damaged during adjacent excavation/construction,
notify the Architect immediately. It is recommended that a licensed Arborist
be secured for the treatment of any possible tree wounds.
3.No disturbance of the soil greater than 4" shall be located closer to the tree
trunk than 1/2 the distance of the drip line to the tree trunk. A minimum of
75% of the drip line and root zone shall be preserved at natural grade.
4.Any fine grading done within the critical root zones of the protected trees must
be done with light machinery such as a bobcat or light tractor. No earth
moving equipment with tracks is allowed within the critical root zone of the
trees.
5.Material Storage: No materials intended for use in construction or waste
materials accumulated due to excavation or demolition shall be placed within
the limits of the dripline of any tree.
6.Equipment Cleaning/Liquid Disposal: No equipment may be cleaned, toxic
solutions, or other liquid chemicals shall be deposited within the limits of the
dripline of a tree. This would include but not be limited to paint, oil, solvents,
asphalt, concrete, mortar, primers, etc.
7.Tree Attachments: No signs, wires or other attachments, other than those of
a protective nature shall be attached to any tree.
8.Vehicular Traffic: No vehicular and construction equipment traffic or parking is
allowed within the limits of the dripline of trees.
9.Boring of Utilities: May be permitted under protected trees in certain
circumstances. The minimum length of the bore shall be the width of the
tree's canopy and shall be a minimum depth of forty-eight (48") inches.
10.Trenching: Any irrigation trenching which must be done within the critical root
zone of a tree shall be dug by hand and enter the area in a radial manner.
11.Tree Flagging: All trees to be removed from the site shall be flagged by the
Contractor with bright red vinyl tape (3" width) wrapped around the main trunk
at a height of four (4') feet above grade. Flagging shall be approved by
Landscape Architect prior to any tree removal. Contractor shall contact
Landscape Architect with 72 hour notice to schedule on-site meeting.
12.Protective Fencing: All trees to remain, as noted on drawings, shall have
protective fencing located at the tree's dripline. The protective fencing may be
comprised of snow fencing, orange vinyl construction fencing, chain link fence
or other similar fencing with a four (4') foot approximate height. The protective
fencing will be located as indicated on the Tree Protection Detail(s).
13.Bark Protection: In situations where a tree remains in the immediate area of
intended construction, the tree shall be protected by enclosing the entire
circumference of the tree's trunk with lumber encircled with wire or other
means that does not damage the tree. Refer to Tree Protection Detail(s).
14.Construction Pruning: In a case where a low hanging limb is broken during
the course of construction, the Contractor shall notify the Landscape Architect
immediately. In no instance shall the Contractor prune any portion of the
damaged tree without the prior approval by the Landscape Architect.
EXISTING TREE
TO BE REMOVED
TREE PROTECTION FENCING
TO REMAIN DURING CONSTRUCTION
REFER TO 01/L1.00
EXISTING TREE
TO REMAIN
EXISTING TREE NOTES
EXISTING TREE LEGEND
OF
F
LIM
I
T
S
ROOT PROTECTION
(RPZ)
LIMITS
OFF
ZONE
OFF
LIMITS
6" MULCH INSIDE RPZ
4'
SEE NOTES
TREE CANOPY
ROOT PROTECTION
ZONE (RPZ)
TREE
TRUNK
01 TREE PROTECTION FENCE A
NOT TO SCALE
NOTE:
FENCING SHOWN ABOVE IS DIAGRAMMATIC ONLY
AND WILL CONFORM TO THE DRIP LINE AND LIMITED
TO PROJECT BOUNDARY
KIDDIE ACADEMYCOLLEYVILLE BLVD.COLLEYVILLE, TEXAS
City of Colleyville Page 1
CITY OF COLLEYVILLE
PLANNING AND ZONING COMMISSION
WORKSESSION BRIEFING
Agenda Number 2d Agenda Date 11/25/2024 Number -
Type Presentation and Discussion
Department Community Development
Title
Presentation and discussion of a change of zoning from AG Agricultural to CC-1 Village
Retail, being Tract 2P, Abstract 973, Absalom J Lott Survey, located at 6312 Colleyville
Boulevard, Case ZC24-029
Explanation
Artuan McGee, the applicant, has submitted a request for a rezoning from AG
Agricultural to CC-1 Village Retail for Tract 2P, Abstract 963, Absalom J Lott Survey,
being approximately 2.798 acres, and zoned AG Agricultural. The request is to rezone
the property to allow development of a two building retail center.
Attachments
1. Aerial Map
2. Zoning Map
3. Statement of Planning Objectives
4. Site Plan
5. Building Elevations
6. Drainage Plan
7. Renderings Provided by Applicant
8. Development Schedule
6125
6255
6301
6505
6509
6513
6517 6516
6512
6508
6504
6500
6416
6305
6412
6408
6404
6400
6308
6304
6300
6309
6401
6405
6409
6413
6417
6501
6301
6505
6509
6513
6517
6305
6309
6401
6405
6409
6413
6417
6501
1800
1802
6113
6118
61146110
6230
6220
6210
6208
6206
6204
6200
6112
6108
6511
6509 1801
1704
6208
1800 1804 1808 1812 1816 1820 1900
6301
1731
1619
6300
6304
6308
6309
1632
6124
6120
6116
6112
6108
6104
6100 1729
6207
6211
6215
6219 6216
6212
6208
6204
6108
6104
6100 6101
6105
6109
6203
6207
6211
6215
6301
6305
6125 6220
6121
6117
6113
6109 6204
6208
6212
6216
1601 1732
6420
6420
6420
6420 6420
6420
6420
6420
6420
64006412
65086504
6416
6500
6515
6513
1901181318091709
6407
6407
6413
6409
1804 1808 1812 1900
62216225
6201
6209 6213 6215
6207
6219
1509
1516
6516
6312
TINKER RD
INDUSTRIAL BLVD
TARRANT LN
OAK POINTE DRCOLLEYVILLE BLVDBRAZOS CTROCK DOVE CIRMCCAIN LN
PONDEROSASTFOUNTAIN PASS DRKINGSTON DRPONDEROSA LNK
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC24-029
6312 Colleyville Blvd
Aerial Map
TINKER RD
INDUSTRIAL BLVD
TARRANT LN
COLLEYVILLE BLVDOAK POINTE DR
BRAZOS CTR O C K DOVECIRWYATT DRHA
R
D
A
G
E
L
N
MCCAIN LN
FOUNTAIN PASS DR
PONDEROSASTKINGSTON DRPONDEROSA LNML
AG
CC-1
R-15
AG
CPO
PUD-C
R-20
PUD-C
PUD-C
PUD-R
R-20
PUD-C
ML
CN
AG
CC-1
CC-2CPO
AG
PUD-C
PUD-R
ML
CC-1
PUD-C
K
Subject Property
DISCLAIMER:
This map and information contained in it were
developed exclusively for use by the City of Colleyville.
Any use or reliance on this map by anyone else is
at that party's risk and without liability to the
City of Colleyville, its officials or employees for any
discrepancies, errors, or variances which may exist.
ZC24-029
6312 Colleyville Blvd
Zoning Map
STATEMENT OF PLANNING OBJECTIVES
The intent of this project is to develop a retail center on a 2.8 acre site located at 6312
Colleyville Boulevard, Colleyville, Texas. The existing zoning of the site is AG. The site is
currently developed but not in use. The proposed zoning change would designate the land
as CC-1 or CC-2.
1322
26 13 15
5
4
19
5
3
2 PARKING: 127 SPACES
LOADING
60'
61'
27'
8'
42'
47'
30'
30'
30'
43'
31'
31'
42'
12'
60'
25'
16'
11'
69'
22'
61'4'4'30'
4'
31'24'
4'
47'4'4'61'
31'
4'
CANOPY
BUILDING B
15,118 SFBUILDING A
9,268 SF
SCREENING
WALL
KNEE
WALL KNEE
WALL
DUMPSTER
AREAPLEASE RECYCLESITE PLAN
----AM
SR
AM
-
-
-
-
-
-
-
-
LEGEND
PROPOSED FIRELANE
ACCESSIBLE CROSSWALK
PROPOSED ACCESSIBLE ROUTE
BFR BARRIER FREE RAMP (ADA RAMP)
GM GAS METER
D.E.DRAINAGE EASEMENT
W.E.WATER EASEMENT
PROPOSED GRATE INLET
PROPOSED JUNCTION BOX
CURB INLET
PROPOSED FIRE HYDRANTF.H.
G.I.
J.B.
C.I.
PROPOSED LIGHT POLE 1-FIXTURE
PROPOSED LIGHT POLE 2-FIXTURES
FDC PROPOSED FIRE DEPT. CONNECTION
DCO PROPOSED SEWER DOUBLE CLEANOUT
CO PROPOSED SEWER SINGLE CLEANOUT
SSMH PROPOSED SEWER MANHOLE
PROPOSED TRANSFORMER PAD
PROPOSED WATER METER AND VAULT
WV
PROPOSED WATER METERWM
PROPOSED WATER VALVE
PROPOSED SIGN
STORM SEWER MANHOLESTMH
WMV
NOTES
1.ALL DIMENSIONS ARE TO FACE OF CURB, FACE OF
WALL, FACE OF BUILDING, CENTER OF STRIPING, AND
PROPERTY LINE UNLESS OTHERWISE NOTED.
2.REFER TO ARCHITECTURAL AND STRUCTURAL PLANS
FOR BUILDING AND DUMPSTER ENCLOSURE LAYOUT
AND DESIGN.
3.REFER TO LANDSCAPE PLANS FOR FENCE AND
HARDSCAPE LAYOUT AND DESIGN.
4.ALL SIGNAGE IS APPROVED VIA A SEPARATE PERMIT
THROUGH THE BUILDING SAFETY DIVISION.
5.ALL MECHANICAL EQUIPMENT, DUMPSTERS, ROOFTOP
UNITS, ETC SHALL BE SCREENED IN COMPLIANCE
WITH THE ZONING ORDINANCE.
6.ALL LIGHTING SHALL COMPLY WITH THE ZONING
ORDINANCE.
7.ANY ALTERATION TO THE SITE PLAN, INCLUDING
BUILDING ELEVATION AND LANDSCAPE
SUBSTITUTIONS, REQUIRE TOWN APPROVAL
THROUGH A REVISED PLAN, STAMPED BY STAFF.
8.ALL STRIPING WITHIN DEVELOPMENT TO BE PAINTED
WHITE.
9.ALL PROPOSED RAMPS TO FOLLOW THE
ARCHITECTURAL BARRIERS TEXAS ACCESSIBILITY
STANDARDS (TAS).
Feet
0 30 60
PLEASE RECYCLENO.DATE REVISION
PROJECT #DESIGNED:
DRAWN:
DATE SHEET
REVIEWER:
BM-1: SET "X"
----------------
----------------
ELEVATION=XXX.XX
N: XXXXXXXXXXXX
E: XXXXXXXXXXXX
TBM-2: SET "X"--------------
----------------
ELEVATION=XXX.XX
N: XXXXXXXXXXXX
E: XXXXXXXXXXXX
BENCHMARK
COLLEYVILLE RETAIL
6312 COLLEYVILLE BLVD.
CITY OF COLLEYVILLE, TARRANT COUNTY, TEXAS
THESE DOCUMENTS ARE FOR DESIGN
REVIEW ONLY AND NOT INTENDED FOR
CONSTRUCTION, BIDDING, OR PERMIT
PURPOSE. THEY ARE PREPARED BY, OR
UNDER THE SUPERVISION OF:
TYPE OR PRINT NAME PE #
PRELIMINARY
-FOR REVIEW ONLY-
ARTUAN MCGEE 147091
DATE
XX/XX/XX
2570 RIVER PARK PLAZA
SUITE 100
FORT WORTH, TEXAS 76116
PHONE #: (817) 529-2700
FIRM NO. 12452
202301510/29/2024
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
October 29, 2024
City Engineer
City of Colleyville, Texas
100 Main Street
Colleyville, Texas 76034
RE: Colleyville Mixed Use Drainage Study and Floodplain Study
Colleyville, Texas
ET 2023015
To Whom it May Concern:
This memo summarizes the Drainage Study and Floodplain Study prepared by Evolving
Texas (“Evolving Texas”) for a proposed Colleyville Mixed Use project located at the
northwest corner of Colleyville Blvd and Tinker Rd. in Colleyville, Texas. The purpose of
this report is to document no adverse impact due to the proposed development as defined
by the City of Colleyville in support of zoning change request.
The property comprises approximately 2.8-acres in the Pecan Creek watershed and is
currently undeveloped. The tract geometry is roughly triangular, bounded on the west by
single family residential, on the north by commercial tracts and on the south and eas t by
Colleyville Boulevard. Pecan Creek enters the site at the southern tip, winds through the
site and exits along the north boundary. Exhibit 1 illustrates the existing site conditions.
Existing flows in Pecan Creek will be conveyed through the property via a box culvert
system sized for a 100-yr storm, following a shifted alignment that allows for a viable and
efficient site layout.
Per revised Panel 48439C0095K of the FEMA Flood Insurance Rate Maps, dated
September 25, 2009, the site is located in Zone X, special flood hazard. However, the
preliminary current effective FEMA Flood Insurance Rate Map for this area is panel
48439C0094L, dated November 13, 2020. It shows the site mapped as Zone AE, subject
to the studied 100-yr floodplain for Pecan Creek. The current effective FEMA floodplain
and the preliminary FEMA Panel are shown in the attachments as Exhibit 2 and 3.
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
HYDROLOGIC ANALYSIS
Evolving Texas developed a hydrology model to assess the hydrologic impact due to
the proposed development. The U.S. Army Corps of Engineers (USACE) HEC-HMS
program, version 4.11, was used to perform the hydrologic analysis. The Natural
Resources Conservation Service’s (NRCS) SCS TR-55 methodology has been used to
calculate the hydrologic parameters.
Curve Numbers (CN) were computed based on a composite percentage of soil types
within each new sub-basin as part of this study. Soil data was obtained from the Soil
Survey data from USDA web soil survey. Precipitation values for 100 -year 24-hour
storm events were obtained from North Central Texas Council of Governments
(NCTCOG) Hydrology iSWM Manual for Tarrant County.
The hydrologic analysis was accomplished to identify existing and proposed discharges
from the drainage areas affected by the proposed Colleyville mixed use development.
The existing conditions consider the site, which is an undeveloped area. The proposed
condition analysis considers the site as developed, with offsite contributing watershed
areas remaining under existing conditions. The point of analysis was downstream of the
proposed site, identified as junction “J-2” in HEC-HMS. Table 1 presents a summary of
hydrology parameters, and Table 2 presents the comparison of 100-yr flows. Exhibit KK
illustrates the overall drainage area map.
Table 1: Hydrology Parameters
Table 2: HEC-HMS 100-yr Flow Comparison
Subbasin Area
(ac.)
Area
(sq. mi.)
Existing Curve
Number
Existing Tc
(min)
Proposed Curve
Number
Proposed Tc
(min)
ON-1 3.08 0.0048 64.87 19.18 92.611 10.00
OS-1 203.36 0.3178 80.71 41.43 80.712 41.43
OS-2 24.82 0.0388 71.86 25.90 71.862 25.90
OS-3 3.77 0.0059 93.90 10.42 93.901 10.42
Hydrology Parameters
Difference
ID Existing Proposed Existing Proposed Prop-Ex
ON-1 2.88 2.88 12.70 24.2 11.50
OS-1 203.39 203.39 793.40 793.4 0.00
OS-2 24.83 24.83 105.00 105 0.00
OS-3 3.78 3.78 30.00 30 0.00
J-1 203.39 203.39 793.40 793.4 0.00
J-2 234.88 234.88 883.00 882.5 -0.50 POA
HEC-HMS FLOW COMPARISON
Colleyville Flood Study, Colleyville, Texas
CommentQ100 (cfs)TOTAL AREA (ac.)
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
HYDRAULIC ANALYSIS
The U.S. Army Corps of Engineers (USACE) HEC-RAS program, version 5.0.7 was
used to perform the hydraulic analysis. As stated above, the subject property lies within
the 100-yr floodplain of Pecan Valley per the Preliminary FEMA FIRM map. FEMA does
not have a finalized model for this Preliminary study. As such, Evolving Texas
developed a HEC-RAS hydraulic model for Pecan Creek to study the hydraulic impacts.
For this analysis the locations of the effective cross sections were obtained off the
FEMA website. Modeling was then performed for both the existing and proposed
conditions. Under proposed conditions, the portion of Pecan Creek running through the
site is to be realigned. A 3-10’X6’ box culvert is proposed to convey existing flows
through the site from offsite areas.
Velocity and 100-yr water surface elevation comparisons are shown in Table 3 below.
Table 3 - HEC-RAS 100-yr WSEL Comparaison
River River
Station QExisting Qproposed
Storm
Freq.
Existing
WSEL
Existing
Vel.
Proposed
WSEL
Proposed
Vel.
Difference
(Proposed-Existing)
WSEL
(ft)(ft/s)(ft)(ft/s)(ft)
Reach 1 7281 793.4 793.4 100 YR 611.35 3.8 608.07 9.5 -3.28
Reach 1 7203 793.4 793.4 100 YR 611.06 4.7 607.91 8.8 -3.15
Reach 1 7131 793.4 793.4 100 YR 609.84 8.6 607.99 7.5 -1.85
Reach 1 6988 793.4 793.4 100 YR 608.84 6.5 608.05 5.9 -0.79
Reach 1 6883 -793.4 100 YR --608.06 5.2 -
Reach 1 6803 883 882.5 100 YR 608.27 4.1 607.96 5.5 -0.31
Reach 1 6675 -882.5 100 YR --607.96 5.0 -
Reach 1 6649 -882.5 100 YR --607.95 4.9 -
Reach 1 6645 883 -100 YR 608.24 3.0 ---
Reach 1 6580 883 882.5 100 YR 606.93 8.8 606.93 8.8 0.00
Reach 1 6524 883 882.5 100 YR 606.07 9.1 606.06 9.1 -0.01
Reach 1 6470 883 882.5 100 YR 605.82 7.2 605.82 7.2 0.00
2023015-Hydraulic Comparison
For the 100-yr Storm Event
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
CONCLUSION
The hydrologic and hydraulic impact analyses indicate that the proposed development
will not increase peak flow to Pecan Creek and will not increase water surface elevations
upstream, downstream, or through the site. Therefore, the proposed site would have no
adverse impact on the adjacent and downstream properties.
Evolving Texas requests the City’s concurrence that the approach outlined above would
be acceptable to the city. If you have any questions or comments on the contents of this
memo, please contact me at samantha@evolvingtexas.com or by phone at 817-529-
2700.
Sincerely,
Samantha Renz, P.E., C.F.M.
Attachments:
Existing Site Conditions
Current Effective FIRM
Preliminary Effective FIRM
Overall Drainage Area Map
Floodplain Workmap
Hydrology Parameters
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
EXHIBIT 1
EXISTING SITE CONDITIONS
EXISTING SITE
CONDITIONS
RKRKMW202301510/29/2024DRAWN BY:DESIGNED BY:CHECKED BY:PROJECT NO.DATE:6312 COLLEYVILLE BLVD.
COLLEYVILLE, TEXAS 76034
RKRKMW202301510/29/2024EXHIBIT 1
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
EXHIBIT 2
CURRENT EFFECTIVE FIRM
SITE
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
EXHIBIT 3
PRELIMINAR EFFECTIVE FIRM
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
EXHIBIT 4
OVERALL DRAINAGE AREA MAP
OS-224.82 ACOS-1203.36 ACON-12.88 ACOS-33.77 ACOVERALL
DRAINAGE AREA
MAPEXHIBIT 4DRAWN BY:DESIGNED BY:CHECKED BY:PROJECT NO.DATE:6312 COLLEYVILLE BLVD.
COLLEYVILLE, TEXAS 76034
RKRKMW202301510/29/2024
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
EXHIBIT 6
FLOODPLAIN WORKMAP
13222613155419532PARKING: 127 SPACESLOADING60'61'27'8'42'47'30'30'30'43'31'31'42'12'60'25'16'11'69'22'61'4'4'30'4'31'24'4'47'4'4'61'31'4'CANOPYDRAWN BY:DESIGNED BY:CHECKED BY:PROJECT NO.DATE:6312 COLLEYVILLE BLVD.
COLLEYVILLE, TEXAS 76034
RKRKMW202301510/29/2024FLOODPLAIN
WORKMAPEXHIBIT 9
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
EXHIBIT 5
HYDROLOGY PARAMETERS
HYDROLOGY PARAMETERS
TIME OF CONCENTRATION
CALCULATIONS
EXISTING AREA - OS-1
For Sheet Flow of less than 300 feet (Manning's)
Tt = (0.007*(n*L)0.8 / P2*0.5*S0.4)*60
Travel Time Tt 5.61 min
Manning's 'n'n 0.150
Length L 100 feet
2-year, 24-hour rainfall P2 3.9 inches
Slope S 0.0650 ft/ft
Shallow Concentrated Flow
Unpaved V = 16.13*(S)0.5
Paved V = 20.33*(S)0.5
Average Velocity V 2.47 (ft/s)
Slope S 0.023 (ft/ft)
Average Velocity V 1.57 (ft/s)
Slope S 0.006 (ft/ft)
Time t 34.88 min
Distance d 3296 feet
Velocity v 1.57 ft/s
Channel Flow
V = (1.49/n)*(R)0.67 * (S)1/2
Tt = L/3600V
{COFW Manual 1.3.6. 1.13 1.9}
Travel time 0.015625 hour 0.9375 min.
Flow Length L 225 feet
Ave. Velocity V 4 ft/sec
Mannings n 0.03 see chart on Mannings Tab
Hydraulic R 9.345794 A/Pw
Slope S 0.035556 ft/ft
Cross Section Area A 1000 ft2
Wetted Perimeter Pw 107 ft
Total Travel Time
Sheet Flow 5.61 Min.
Shallow Concentrated Flow 34.88 Min.
Channel Flow 0.9375 Min.
TOTAL TIME 41.43 Min.
LAG TIME 24.86 Min.
EXISTING AREA - OS-2
For Sheet Flow of less than 300 feet (Manning's)
Tt = (0.007*(n*L)0.8 / P2*0.5*S0.4)*60
Travel TimeTt 13.68 min
Manning's 'n'n 0.150
Length L 100 feet
2-year, 24-hour rainfallP2 3.9 inches
Slope S 0.0070 ft/ft
Shallow Concentrated Flow
Unpaved V = 16.13*(S)0.5
Paved V = 20.33*(S)0.5
Unpaved Average VelocityV 3.02 (ft/s)
Slope S 0.035 (ft/ft)
Paved Average VelocityV 1.57 (ft/s)
Slope S 0.006 (ft/ft)
Time t 11.41 min
Distance d 1078 feet
Velocity v 1.57 ft/s
Channel Flow
V = (1.49/n)*(R)0.67 * (S)1/2
Tt = L/3600V
{COFW Manual 1.3.6. 1.13 1.9}
Travel time 0.013472 hour 0.808333 min.
Flow LengthL 194 feet
Ave. VelocityV 4 ft/sec
Mannings n 0.03 see chart on Mannings Tab
Hydraulic R 9.345794 A/Pw
Slope S 0.004 ft/ft
Cross Section AreaA 1000 ft2
Wetted PerimeterPw 107 ft
Total Travel Time
Sheet Flow 13.68 Min.
Shallow Concentrated Flow 11.41 Min.
Channel Flow 0.808333 Min.
TOTAL TIME 25.90 Min.
LAG TIME 15.5378 Min.
EXISTING AREA - OS-3
For Sheet Flow of less than 300 feet (Manning's)
Tt = (0.007*(n*L)0.8 / P2*0.5*S0.4)*60
Travel TimeTt 5.79 min
Manning's 'n'n 0.150
Length L 100 feet
2-year, 24-hour rainfallP2 3.9 inches
Slope S 0.0600 ft/ft
Shallow Concentrated Flow
Unpaved V = 16.13*(S)0.5
Paved V = 20.33*(S)0.5
Unpaved Average VelocityV 2.18 (ft/s)
Slope S 0.018 (ft/ft)
Paved Average VelocityV 1.57 (ft/s)
Slope S 0.006 (ft/ft)
Time t 4.63 min
Distance d 437 feet
Velocity v 1.57 ft/s
Channel Flow
V = (1.49/n)*(R)0.67 * (S)1/2
Tt = L/3600V
{COFW Manual 1.3.6. 1.13 1.9}
Travel time 0 hour 0 min.
Flow LengthL 0 feet
Ave. VelocityV 4 ft/sec
Mannings n 0.03 see chart on Mannings Tab
Hydraulic R 9.345794 A/Pw
Slope S 0.004 ft/ft
Cross Section AreaA 1000 ft2
Wetted PerimeterPw 107 ft
Total Travel Time
Sheet Flow 5.79 Min.
Shallow Concentrated Flow 4.63 Min.
Channel Flow 0 Min.
TOTAL TIME 10.42 Min.
LAG TIME 6.250224 Min.
EXISTING AREA - ON-1
For Sheet Flow of less than 300 feet (Manning's)
Tt = (0.007*(n*L)0.8 / P2*0.5*S0.4)*60
Travel TimeTt 15.75 min
Manning's 'n'n 0.400
Length L 100 feet
2-year, 24-hour rainfallP2 3.9 inches
Slope S 0.0350 ft/ft
Shallow Concentrated Flow
Unpaved V = 16.13*(S)0.5
Paved V = 20.33*(S)0.5
Unpaved Average VelocityV 2.01 (ft/s)
Slope S 0.016 (ft/ft)0.030435
Paved Average VelocityV 1.57 (ft/s)
Slope S 0.006 (ft/ft)
Time t 1.86 min
Distance d 225 feet
Velocity v 2.01 ft/s
Channel Flow
V = (1.49/n)*(R)0.67 * (S)1/2
Tt = L/3600V
{COFW Manual 1.3.6. 1.13 1.9}
Travel time 0.026111 hour 1.566667 min.
Flow LengthL 376 feet
Ave. VelocityV 4 ft/sec
Mannings n 0.03 see chart on Mannings Tab
Hydraulic R 9.345794 A/Pw
Slope S 0.004 ft/ft
Cross Section AreaA 1000 ft2
Wetted PerimeterPw 107 ft
Total Travel Time
Sheet Flow 15.75 Min.
Shallow Concentrated Flow 1.86 Min.
Channel Flow 1.566667 Min.
TOTAL TIME 19.18 Min.
LAG TIME 11.50744 Min.
PROPOSED AREA - ON-1
For Sheet Flow of less than 300 feet (Manning's)
Tt = (0.007*(n*L)0.8 / P2*0.5*S0.4)*60
Travel TimeTt 1.16 min
Manning's 'n'n 0.010
Length L 100 feet
2-year, 24-hour rainfallP2 3.9 inches
Slope S 0.0150 ft/ft
Shallow Concentrated Flow
Unpaved V = 16.13*(S)0.5
Paved V = 20.33*(S)0.5
Unpaved Average VelocityV 2.98 (ft/s)
Slope S 0.034 (ft/ft)
Paved Average VelocityV 1.57 (ft/s)
Slope S 0.006 (ft/ft)
Time t 2.48 min
Distance d 234 feet
Velocity v 1.57 ft/s
Channel Flow
V = (1.49/n)*(R)0.67 * (S)1/2
Tt = L/3600V
{COFW Manual 1.3.6. 1.13 1.9}
Travel time 0.023194 hour 1.391667 min.
Flow LengthL 334 feet
Ave. VelocityV 4 ft/sec
Mannings n 0.03 see chart on Mannings Tab
Hydraulic R 9.345794 A/Pw
Slope S 0.004 ft/ft
Cross Section AreaA 1000 ft2
Wetted PerimeterPw 107 ft
Total Travel Time
Sheet Flow 1.16 Min.
Shallow Concentrated Flow 2.48 Min.
Channel Flow 1.391667 Min.
TOTAL TIME 5.02 Min.
Min time=10 Min.
LAG TIME 6 Min.
HYDROLOGY PARAMETERS
COMPOSITE CN NUMBER
CALCULATIONS
AREA NAME LandUse Area MUSYM Soil_Group CN CN*Area
OS-1 Residential districts: 1/4 acre 43.5600 BmC C 83 3615.48
OS-1 Urban districts: Commercial and business 609.8400 BmC C 94 57324.96
OS-1 Urban districts: Commercial and business 0.0000 BmC C 94 0
OS-1 Impervious areas: Paved; curbs and storm drains 7100.2800 BmC C 98 695827.4
OS-1 Open space: Good condition 550772.6400 BmC C 74 40757175
OS-3 Urban districts: Commercial and business 3528.3600 RaA C 94 331665.8
OS-1 Residential districts: 1/4 acre 87.1200 CrD D 87 7579.44
OS-1 Impervious areas: Paved; curbs and storm drains 0.0000 CrD D 98 0
OS-1 Impervious areas: Paved; curbs and storm drains 130.6800 CrD D 98 12806.64
OS-1 Impervious areas: Paved; curbs and storm drains 35457.8400 CrD D 98 3474868
OS-1 Open space: Good condition 61332.4800 CrD D 80 4906598
OS-1 Urban districts: Commercial and business 32321.5200 GuC B 92 2973580
OS-1 Residential districts: 1/2 acre 16901.2800 GuC B 70 1183090
OS-1 Urban districts: Commercial and business 68302.0800 GuC B 92 6283791
OS-1 Residential districts: 1/4 acre 230563.0800 GuC B 75 17292231
OS-1 Pasture or range land: good condition 177463.4400 GuC B 61 10825270
OS-1 Urban districts: Commercial and business 40205.8800 GuC B 92 3698941
OS-1 Impervious areas: Paved; curbs and storm drains 188484.1200 GuC B 98 18471444
OS-1 Pasture or range land: good condition 696.9600 GfB B 61 42514.56
OS-1 Residential districts: 1 acre 46391.4000 GfB B 68 3154615
OS-1 Residential districts: 1/2 acre 82720.4400 GfB B 70 5790431
OS-1 Residential districts: 1/2 acre 91345.3200 GfB B 70 6394172
OS-1 Residential districts: 1/2 acre 82371.9600 GfB B 70 5766037
OS-1 Impervious areas: Paved; curbs and storm drains 53622.3600 GfB B 98 5254991
OS-1 Pasture or range land: good condition 1437.4800 RuA C 74 106373.5
ON-1 Pasture or range land: good condition 5009.4000 RuA C 74 370695.6
OS-3 Pasture or range land: good condition 43.5600 RuA C 74 3223.44
OS-1 Pasture or range land: good condition 0.0000 RuA C 74 0
OS-1 Residential districts: 1/3 acre 0.0000 RuA C 81 0
OS-1 Urban districts: Commercial and business 97138.8000 RuA C 94 9131047
OS-1 Pasture or range land: good condition 392.0400 RuA C 74 29010.96
OS-3 Urban districts: Commercial and business 1176.1200 RuA C 94 110555.3
OS-1 Urban districts: Commercial and business 25787.5200 RuA C 94 2424027
OS-1 Residential districts: 1/4 acre 8232.8400 RuA C 83 683325.7
OS-1 Residential districts: 1/4 acre 2787.8400 RuA C 83 231390.7
OS-1 Residential districts: 1/4 acre 7318.0800 RuA C 83 607400.6
OS-1 Residential districts: 1/4 acre 0.0000 RuA C 83 0
OS-1 Impervious areas: Paved; curbs and storm drains 7927.9200 RuA C 98 776936.2
OS-1 Urban districts: Commercial and business 207911.8800 RuA C 94 19543717
OS-1 Urban districts: Commercial and business 641900.1600 RuA C 94 60338615
ON-1 Impervious areas: Paved; curbs and storm drains 43.5600 RuA C 98 4268.88
OS-3 Impervious areas: Paved; curbs and storm drains 15725.1600 RuA C 98 1541066
OS-1 Impervious areas: Paved; curbs and storm drains 291198.6000 RuA C 98 28537463
OS-1 Open space: Good condition 823850.2800 RuA C 74 60964921
OS-1 Residential districts: 1/4 acre 26963.6400 GgC B 75 2022273
OS-1 Residential districts: 1/4 acre 109030.6800 GgC B 75 8177301
OS-1 Impervious areas: Paved; curbs and storm drains 26876.5200 GgC B 98 2633899
OS-1 Residential districts: 1/4 acre 2570.0400 SsD B 75 192753
OS-1 Residential districts: 1/4 acre 827.6400 SsD B 75 62073
OS-1 Residential districts: 1/4 acre 84288.6000 SsD B 75 6321645
OS-1 Impervious areas: Paved; curbs and storm drains 31537.4400 SsD B 98 3090669
OS-1 Impervious areas: Paved; curbs and storm drains 0.0000 SsD B 98 0
OS-1 Residential districts: 1/2 acre 92565.0000 GfB B 70 6479550
OS-1 Residential districts: 1/2 acre 224072.6400 GfB B 70 15685085
OS-1 Residential districts: 1/2 acre 19471.3200 GfB B 70 1362992
OS-1 Residential districts: 1/3 acre 32495.7600 GfB B 72 2339695
OS-1 Residential districts: 1/3 acre 9931.6800 GfB B 72 715081
OS-1 Urban districts: Commercial and business 8145.7200 GfB B 92 749406.2
OS-1 Residential districts: 1/4 acre 6838.9200 GfB B 75 512919
OS-1 Impervious areas: Paved; curbs and storm drains 86902.2000 GfB B 98 8516416
OS-1 Pasture or range land: good condition 31973.0400 SsD B 61 1950355
OS-1 Pasture or range land: good condition 43167.9600 SsD B 61 2633246
ON-1 Pasture or range land: good condition 81675.0000 SsD B 61 4982175
OS-2 Pasture or range land: good condition 653.4000 SsD B 61 39857.4
OS-2 Residential districts: 1/2 acre 255566.5200 SsD B 70 17889656
OS-1 Residential districts: 1/2 acre 3005.6400 SsD B 70 210394.8
OS-2 Residential districts: 1/2 acre 168010.9200 SsD B 70 11760764
OS-1 Residential districts: 1/2 acre 9147.6000 SsD B 70 640332
OS-2 Urban districts: Commercial and business 44039.1600 SsD B 92 4051603
OS-2 Pasture or range land: good condition 100797.8400 SsD B 61 6148668
OS-1 Pasture or range land: good condition 130984.9200 SsD B 61 7990080
OS-1 Residential districts: 1/2 acre 653.4000 SsD B 70 45738
OS-1 Residential districts: 1/2 acre 228428.6400 SsD B 70 15990005
OS-1 Residential districts: 1/3 acre 92521.4400 SsD B 72 6661544
OS-1 Urban districts: Commercial and business 225945.7200 SsD B 92 20787006
OS-1 Residential districts: 1/2 acre 45912.2400 SsD B 70 3213857
ON-1 Impervious areas: Paved; curbs and storm drains 43.5600 SsD B 98 4268.88
OS-3 Impervious areas: Paved; curbs and storm drains 87.1200 SsD B 98 8537.76
OS-2 Impervious areas: Paved; curbs and storm drains 64599.4800 SsD B 98 6330749
OS-1 Impervious areas: Paved; curbs and storm drains 110860.2000 SsD B 98 10864300
OS-1 Residential districts: 1/4 acre 827.6400 GfC B 75 62073
OS-1 Residential districts: 1/4 acre 46565.6400 GfC B 75 3492423
ON-1 Pasture or range land: good condition 18208.0800 GfC B 61 1110693
OS-3 Urban districts: Commercial and business 108856.4400 GfC B 92 10014792
OS-1 Urban districts: Commercial and business 46609.2000 GfC B 92 4288046
OS-1 Residential districts: 1/4 acre 11586.9600 GfC B 75 869022
OS-1 Residential districts: 1/4 acre 8102.1600 GfC B 75 607662
OS-1 Residential districts: 1/4 acre 95309.2800 GfC B 75 7148196
OS-1 Residential districts: 1/4 acre 92782.8000 GfC B 75 6958710
OS-1 Residential districts: 1/4 acre 50355.3600 GfC B 75 3776652
OS-1 Residential districts: 1/4 acre 27355.6800 GfC B 75 2051676
OS-1 Residential districts: 1/4 acre 37418.0400 GfC B 75 2806353
OS-1 Impervious areas: Paved; curbs and storm drains 159037.5600 GfC B 98 15585681
OS-1 Urban districts: Commercial and business 8232.8400 GfC B 92 757421.3
ON-1 Impervious areas: Paved; curbs and storm drains 914.7600 GfC B 98 89646.48
OS-3 Impervious areas: Paved; curbs and storm drains 31929.4800 GfC B 98 3129089
OS-1 Impervious areas: Paved; curbs and storm drains 3920.4000 GfC B 98 384199.2
OS-1 Residential districts: 1/2 acre 6577.5600 CrB D 85 559092.6
OS-1 Residential districts: 1/3 acre 41991.8400 CrB D 86 3611298
OS-1 Residential districts: 1/3 acre 8232.8400 CrB D 86 708024.2
EXISTING COMPOSITE CN CALCULATIONS
OS-1 Urban districts: Commercial and business 65732.0400 CrB D 95 6244544
OS-1 Urban districts: Commercial and business 26658.7200 CrB D 95 2532578
OS-1 Impervious areas: Paved; curbs and storm drains 41033.5200 CrB D 98 4021285
ON-1 Pasture or range land: good condition 20081.1600 CrB D 80 1606493
OS-2 Pasture or range land: good condition 174.2400 CrB D 80 13939.2
OS-3 Urban districts: Commercial and business 130.6800 CrB D 95 12414.6
OS-2 Urban districts: Commercial and business 20734.5600 CrB D 95 1969783
ON-1 Impervious areas: Paved; curbs and storm drains 130.6800 CrB D 98 12806.64
OS-3 Impervious areas: Paved; curbs and storm drains 2787.8400 CrB D 98 273208.3
OS-2 Impervious areas: Paved; curbs and storm drains 1306.8000 CrB D 98 128066.4
OS-1 Residential districts: 1/2 acre 3354.1200 BmC C 80 268329.6
OS-2 Pasture or range land: good condition 83504.5200 BmC C 74 6179334
OS-1 Pasture or range land: good condition 43080.8400 BmC C 74 3187982
OS-2 Residential districts: 1/2 acre 2047.3200 BmC C 80 163785.6
OS-1 Residential districts: 1/2 acre 72396.7200 BmC C 80 5791738
OS-2 Residential districts: 1/2 acre 740.5200 BmC C 80 59241.6
OS-1 Impervious areas: Paved; curbs and storm drains 12283.9200 BmC C 98 1203824
OS-1 Residential districts: 1/4 acre 5445.0000 GfB B 75 408375
OS-1 Residential districts: 1/4 acre 4138.2000 GfB B 75 310365
OS-1 Residential districts: 1/4 acre 141003.7200 GfB B 75 10575279
OS-1 Urban districts: Commercial and business 615023.6400 GfB B 92 56582175
OS-1 Impervious areas: Paved; curbs and storm drains 9844.5600 GfB B 98 964766.9
OS-1 Open space: Good condition 106460.6400 GfB B 61 6494099
OS-1 Impervious areas: Paved; curbs and storm drains 1785.9600 GfB B 98 175024.1
OS-1 Pasture or range land: good condition 11282.0400 GfC B 61 688204.4
OS-2 Residential districts: 1/2 acre 169012.8000 GfC B 70 11830896
OS-1 Residential districts: 1/2 acre 80193.9600 GfC B 70 5613577
OS-2 Pasture or range land: good condition 146971.4400 GfC B 61 8965258
OS-1 Pasture or range land: good condition 43.5600 GfC B 61 2657.16
OS-2 Residential districts: 1/2 acre 1916.6400 GfC B 70 134164.8
OS-1 Residential districts: 1/2 acre 5140.0800 GfC B 70 359805.6
OS-1 Residential districts: 1/2 acre 35065.8000 GfC B 70 2454606
OS-1 Residential districts: 1/3 acre 52794.7200 GfC B 72 3801220
OS-1 Urban districts: Commercial and business 26005.3200 GfC B 92 2392489
OS-2 Impervious areas: Paved; curbs and storm drains 19819.8000 GfC B 98 1942340
OS-1 Impervious areas: Paved; curbs and storm drains 34891.5600 GfC B 98 3419373
OS-2 Pasture or range land: good condition 130.6800 GfC B 61 7971.48
OS-1 Pasture or range land: good condition 4791.6000 GfC B 61 292287.6
OS-1 Residential districts: 1 acre 34848.0000 GfC B 68 2369664
OS-1 Residential districts: 1/2 acre 116610.1200 GfC B 70 8162708
OS-1 Residential districts: 1/2 acre 572334.8400 GfC B 70 40063439
OS-1 Residential districts: 1/2 acre 163916.2800 GfC B 70 11474140
OS-2 Residential districts: 1/2 acre 1437.4800 GfC B 70 100623.6
OS-1 Residential districts: 1/2 acre 65514.2400 GfC B 70 4585997
OS-1 Impervious areas: Paved; curbs and storm drains 112254.1200 GfC B 98 11000904
OS-1 Residential districts: 1/2 acre 75141.0000 CuC D 85 6386985
OS-1 Residential districts: 1/4 acre 52794.7200 CuC D 87 4593141
OS-1 Pasture or range land: good condition 37984.3200 CuC D 80 3038746
OS-1 Impervious areas: Paved; curbs and storm drains 17946.7200 CuC D 98 1758779
Total 10232461.8
Subbasins Area CN*Area Composite CN
Name (sf)(ac)
ON-1 126106.2 8181047.16 64.87
OS-1 8860626.72 715155360 80.71
OS-2 1081464.12 77716702.8 71.86
OS-3 164264.76 15424552.4 93.90
AREA NAME LandUse Area MUSYM Soil_Group CN CN*Area
OS-1 Residential districts: 1/4 acre 43.5600 BmC C 83 3615.48
OS-1 Urban districts: Commercial and business 609.8400 BmC C 94 57324.96
OS-1 Urban districts: Commercial and business 0.0000 BmC C 94 0
OS-1 Impervious areas: Paved; curbs and storm drains 7100.2800 BmC C 98 695827.4
OS-1 Open space: Good condition 550772.6400 BmC C 74 40757175
OS-3 Urban districts: Commercial and business 3528.3600 RaA C 94 331665.8
OS-1 Residential districts: 1/4 acre 87.1200 CrD D 87 7579.44
OS-1 Impervious areas: Paved; curbs and storm drains 0.0000 CrD D 98 0
OS-1 Impervious areas: Paved; curbs and storm drains 130.6800 CrD D 98 12806.64
OS-1 Impervious areas: Paved; curbs and storm drains 35457.8400 CrD D 98 3474868
OS-1 Open space: Good condition 61332.4800 CrD D 80 4906598
OS-1 Urban districts: Commercial and business 32321.5200 GuC B 92 2973580
OS-1 Residential districts: 1/2 acre 16901.2800 GuC B 70 1183090
OS-1 Urban districts: Commercial and business 68302.0800 GuC B 92 6283791
OS-1 Residential districts: 1/4 acre 230563.0800 GuC B 75 17292231
OS-1 Pasture or range land: good condition 177463.4400 GuC B 61 10825270
OS-1 Urban districts: Commercial and business 40205.8800 GuC B 92 3698941
OS-1 Impervious areas: Paved; curbs and storm drains 188484.1200 GuC B 98 18471444
OS-1 Pasture or range land: good condition 696.9600 GfB B 61 42514.56
OS-1 Residential districts: 1 acre 46391.4000 GfB B 68 3154615
OS-1 Residential districts: 1/2 acre 82720.4400 GfB B 70 5790431
OS-1 Residential districts: 1/2 acre 91345.3200 GfB B 70 6394172
OS-1 Residential districts: 1/2 acre 82371.9600 GfB B 70 5766037
OS-1 Impervious areas: Paved; curbs and storm drains 53622.3600 GfB B 98 5254991
OS-1 Pasture or range land: good condition 1437.4800 RuA C 74 106373.5
ON-1 Urban districts: Commercial and business 5009.4000 RuA C 94 470883.6
OS-3 Pasture or range land: good condition 43.5600 RuA C 74 3223.44
OS-1 Pasture or range land: good condition 0.0000 RuA C 74 0
OS-1 Residential districts: 1/3 acre 0.0000 RuA C 81 0
OS-1 Urban districts: Commercial and business 97138.8000 RuA C 94 9131047
OS-1 Pasture or range land: good condition 392.0400 RuA C 74 29010.96
OS-3 Urban districts: Commercial and business 1176.1200 RuA C 94 110555.3
OS-1 Urban districts: Commercial and business 25787.5200 RuA C 94 2424027
OS-1 Residential districts: 1/4 acre 8232.8400 RuA C 83 683325.7
OS-1 Residential districts: 1/4 acre 2787.8400 RuA C 83 231390.7
OS-1 Residential districts: 1/4 acre 7318.0800 RuA C 83 607400.6
OS-1 Residential districts: 1/4 acre 0.0000 RuA C 83 0
OS-1 Impervious areas: Paved; curbs and storm drains 7927.9200 RuA C 98 776936.2
OS-1 Urban districts: Commercial and business 207911.8800 RuA C 94 19543717
OS-1 Urban districts: Commercial and business 641900.1600 RuA C 94 60338615
ON-1 Impervious areas: Paved; curbs and storm drains 43.5600 RuA C 98 4268.88
OS-3 Impervious areas: Paved; curbs and storm drains 15725.1600 RuA C 98 1541066
OS-1 Impervious areas: Paved; curbs and storm drains 291198.6000 RuA C 98 28537463
OS-1 Open space: Good condition 823850.2800 RuA C 74 60964921
OS-1 Residential districts: 1/4 acre 26963.6400 GgC B 75 2022273
OS-1 Residential districts: 1/4 acre 109030.6800 GgC B 75 8177301
OS-1 Impervious areas: Paved; curbs and storm drains 26876.5200 GgC B 98 2633899
OS-1 Residential districts: 1/4 acre 2570.0400 SsD B 75 192753
OS-1 Residential districts: 1/4 acre 827.6400 SsD B 75 62073
OS-1 Residential districts: 1/4 acre 84288.6000 SsD B 75 6321645
OS-1 Impervious areas: Paved; curbs and storm drains 31537.4400 SsD B 98 3090669
OS-1 Impervious areas: Paved; curbs and storm drains 0.0000 SsD B 98 0
OS-1 Residential districts: 1/2 acre 92565.0000 GfB B 70 6479550
OS-1 Residential districts: 1/2 acre 224072.6400 GfB B 70 15685085
OS-1 Residential districts: 1/2 acre 19471.3200 GfB B 70 1362992
OS-1 Residential districts: 1/3 acre 32495.7600 GfB B 72 2339695
OS-1 Residential districts: 1/3 acre 9931.6800 GfB B 72 715081
OS-1 Urban districts: Commercial and business 8145.7200 GfB B 92 749406.2
OS-1 Residential districts: 1/4 acre 6838.9200 GfB B 75 512919
OS-1 Impervious areas: Paved; curbs and storm drains 86902.2000 GfB B 98 8516416
OS-1 Pasture or range land: good condition 31973.0400 SsD B 61 1950355
OS-1 Pasture or range land: good condition 43167.9600 SsD B 61 2633246
ON-1 Urban districts: Commercial and business 81675.0000 SsD B 92 7514100
OS-2 Pasture or range land: good condition 653.4000 SsD B 61 39857.4
OS-2 Residential districts: 1/2 acre 255566.5200 SsD B 70 17889656
OS-1 Residential districts: 1/2 acre 3005.6400 SsD B 70 210394.8
OS-2 Residential districts: 1/2 acre 168010.9200 SsD B 70 11760764
OS-1 Residential districts: 1/2 acre 9147.6000 SsD B 70 640332
OS-2 Urban districts: Commercial and business 44039.1600 SsD B 92 4051603
OS-2 Pasture or range land: good condition 100797.8400 SsD B 61 6148668
OS-1 Pasture or range land: good condition 130984.9200 SsD B 61 7990080
OS-1 Residential districts: 1/2 acre 653.4000 SsD B 70 45738
OS-1 Residential districts: 1/2 acre 228428.6400 SsD B 70 15990005
OS-1 Residential districts: 1/3 acre 92521.4400 SsD B 72 6661544
OS-1 Urban districts: Commercial and business 225945.7200 SsD B 92 20787006
OS-1 Residential districts: 1/2 acre 45912.2400 SsD B 70 3213857
ON-1 Impervious areas: Paved; curbs and storm drains 43.5600 SsD B 98 4268.88
OS-3 Impervious areas: Paved; curbs and storm drains 87.1200 SsD B 98 8537.76
OS-2 Impervious areas: Paved; curbs and storm drains 64599.4800 SsD B 98 6330749
OS-1 Impervious areas: Paved; curbs and storm drains 110860.2000 SsD B 98 10864300
OS-1 Residential districts: 1/4 acre 827.6400 GfC B 75 62073
OS-1 Residential districts: 1/4 acre 46565.6400 GfC B 75 3492423
ON-1 Urban districts: Commercial and business 18208.0800 GfC B 92 1675143
OS-3 Urban districts: Commercial and business 108856.4400 GfC B 92 10014792
OS-1 Urban districts: Commercial and business 46609.2000 GfC B 92 4288046
OS-1 Residential districts: 1/4 acre 11586.9600 GfC B 75 869022
OS-1 Residential districts: 1/4 acre 8102.1600 GfC B 75 607662
OS-1 Residential districts: 1/4 acre 95309.2800 GfC B 75 7148196
OS-1 Residential districts: 1/4 acre 92782.8000 GfC B 75 6958710
OS-1 Residential districts: 1/4 acre 50355.3600 GfC B 75 3776652
OS-1 Residential districts: 1/4 acre 27355.6800 GfC B 75 2051676
OS-1 Residential districts: 1/4 acre 37418.0400 GfC B 75 2806353
OS-1 Impervious areas: Paved; curbs and storm drains 159037.5600 GfC B 98 15585681
OS-1 Urban districts: Commercial and business 8232.8400 GfC B 92 757421.3
ON-1 Impervious areas: Paved; curbs and storm drains 914.7600 GfC B 98 89646.48
OS-3 Impervious areas: Paved; curbs and storm drains 31929.4800 GfC B 98 3129089
OS-1 Impervious areas: Paved; curbs and storm drains 3920.4000 GfC B 98 384199.2
OS-1 Residential districts: 1/2 acre 6577.5600 CrB D 85 559092.6
OS-1 Residential districts: 1/3 acre 41991.8400 CrB D 86 3611298
OS-1 Residential districts: 1/3 acre 8232.8400 CrB D 86 708024.2
PROPOSED COMPOSITE CN CALCULATIONS
OS-1 Urban districts: Commercial and business 65732.0400 CrB D 95 6244544
OS-1 Urban districts: Commercial and business 26658.7200 CrB D 95 2532578
OS-1 Impervious areas: Paved; curbs and storm drains 41033.5200 CrB D 98 4021285
ON-1 Urban districts: Commercial and business 20081.1600 CrB D 95 1907710
OS-2 Pasture or range land: good condition 174.2400 CrB D 80 13939.2
OS-3 Urban districts: Commercial and business 130.6800 CrB D 95 12414.6
OS-2 Urban districts: Commercial and business 20734.5600 CrB D 95 1969783
ON-1 Impervious areas: Paved; curbs and storm drains 130.6800 CrB D 98 12806.64
OS-3 Impervious areas: Paved; curbs and storm drains 2787.8400 CrB D 98 273208.3
OS-2 Impervious areas: Paved; curbs and storm drains 1306.8000 CrB D 98 128066.4
OS-1 Residential districts: 1/2 acre 3354.1200 BmC C 80 268329.6
OS-2 Pasture or range land: good condition 83504.5200 BmC C 74 6179334
OS-1 Pasture or range land: good condition 43080.8400 BmC C 74 3187982
OS-2 Residential districts: 1/2 acre 2047.3200 BmC C 80 163785.6
OS-1 Residential districts: 1/2 acre 72396.7200 BmC C 80 5791738
OS-2 Residential districts: 1/2 acre 740.5200 BmC C 80 59241.6
OS-1 Impervious areas: Paved; curbs and storm drains 12283.9200 BmC C 98 1203824
OS-1 Residential districts: 1/4 acre 5445.0000 GfB B 75 408375
OS-1 Residential districts: 1/4 acre 4138.2000 GfB B 75 310365
OS-1 Residential districts: 1/4 acre 141003.7200 GfB B 75 10575279
OS-1 Urban districts: Commercial and business 615023.6400 GfB B 92 56582175
OS-1 Impervious areas: Paved; curbs and storm drains 9844.5600 GfB B 98 964766.9
OS-1 Open space: Good condition 106460.6400 GfB B 61 6494099
OS-1 Impervious areas: Paved; curbs and storm drains 1785.9600 GfB B 98 175024.1
OS-1 Pasture or range land: good condition 11282.0400 GfC B 61 688204.4
OS-2 Residential districts: 1/2 acre 169012.8000 GfC B 70 11830896
OS-1 Residential districts: 1/2 acre 80193.9600 GfC B 70 5613577
OS-2 Pasture or range land: good condition 146971.4400 GfC B 61 8965258
OS-1 Pasture or range land: good condition 43.5600 GfC B 61 2657.16
OS-2 Residential districts: 1/2 acre 1916.6400 GfC B 70 134164.8
OS-1 Residential districts: 1/2 acre 5140.0800 GfC B 70 359805.6
OS-1 Residential districts: 1/2 acre 35065.8000 GfC B 70 2454606
OS-1 Residential districts: 1/3 acre 52794.7200 GfC B 72 3801220
OS-1 Urban districts: Commercial and business 26005.3200 GfC B 92 2392489
OS-2 Impervious areas: Paved; curbs and storm drains 19819.8000 GfC B 98 1942340
OS-1 Impervious areas: Paved; curbs and storm drains 34891.5600 GfC B 98 3419373
OS-2 Pasture or range land: good condition 130.6800 GfC B 61 7971.48
OS-1 Pasture or range land: good condition 4791.6000 GfC B 61 292287.6
OS-1 Residential districts: 1 acre 34848.0000 GfC B 68 2369664
OS-1 Residential districts: 1/2 acre 116610.1200 GfC B 70 8162708
OS-1 Residential districts: 1/2 acre 572334.8400 GfC B 70 40063439
OS-1 Residential districts: 1/2 acre 163916.2800 GfC B 70 11474140
OS-2 Residential districts: 1/2 acre 1437.4800 GfC B 70 100623.6
OS-1 Residential districts: 1/2 acre 65514.2400 GfC B 70 4585997
OS-1 Impervious areas: Paved; curbs and storm drains 112254.1200 GfC B 98 11000904
OS-1 Residential districts: 1/2 acre 75141.0000 CuC D 85 6386985
OS-1 Residential districts: 1/4 acre 52794.7200 CuC D 87 4593141
OS-1 Pasture or range land: good condition 37984.3200 CuC D 80 3038746
OS-1 Impervious areas: Paved; curbs and storm drains 17946.7200 CuC D 98 1758779
Total 10232461.8
Subbasins Area CN*Area Composite CN
Name (sf)(ac)
ON-1 126106.2 11678828 92.61
OS-1 8860626.72 715155360 80.71
OS-2 1081464.12 77716702.8 71.86
OS-3 164264.76 15424552.4 93.90
2750 River Park Plaza, Suite 100 | Fort Worth, TX 76116 | 817-529-2700
EXHIBIT 7
HEC-RAS HYDRAULIC TABLES
River River
Station QExisting Qproposed
Storm
Freq.
Existing
WSEL
Existing
Vel.
Proposed
WSEL Proposed Vel.Difference (Proposed-
Existing) WSEL
(ft)(ft/s)(ft)(ft/s)(ft)
Reach 1 7281 793.4 793.4 100 YR 611.35 3.8 608.07 9.5 -3.28
Reach 1 7203 793.4 793.4 100 YR 611.06 4.7 607.91 8.8 -3.15
Reach 1 7131 793.4 793.4 100 YR 609.84 8.6 607.99 7.5 -1.85
Reach 1 6988 793.4 793.4 100 YR 608.84 6.5 608.05 5.9 -0.79
Reach 1 6883 -793.4 100 YR --608.06 5.2 -
Reach 1 6803 883 882.5 100 YR 608.27 4.1 607.96 5.5 -0.31
Reach 1 6675 -882.5 100 YR --607.96 5.0 -
Reach 1 6649 -882.5 100 YR --607.95 4.9 -
Reach 1 6645 883 -100 YR 608.24 3.0 ---
Reach 1 6580 883 882.5 100 YR 606.93 8.8 606.93 8.8 0.00
Reach 1 6524 883 882.5 100 YR 606.07 9.1 606.06 9.1 -0.01
Reach 1 6470 883 882.5 100 YR 605.82 7.2 605.82 7.2 0.00
2023015-Hydraulic Comparison
For the 100-yr Storm Event
COLLEYVILLE RETAILCOLLEYVILLE RETAIL
NOVEMBER 01, 2024
NOVEMBER 01, 2024PERSPECTIVE 1
NOVEMBER 01, 2024PERSPECTIVE 2
NOVEMBER 01, 2024PERSPECTIVE 3
NOVEMBER 01, 2024PERSPECTIVE 4
NOVEMBER 01, 2024PERSPECTIVE 5
NOVEMBER 01, 2024PERSPECTIVE 6
DEVELOPMENT SCHEDULE
The proposed development will follow the time frame allowed by the City of Colleyville after
the CLOMR has been approved by FEMA, all applicable construction plans have been
approved, and all applicable forms and documents have been received by the City of
Colleyville to begin and complete construction in a timely manner. The plan is to have the
construction begin some time in 2025 and be completed some time in 2026.